Ventilation Fan Catalogue Proven, Reliable Bathroom Ventilation Solutions
Ventilation Fan Catalogue
Proven, Reliable Bathroom Ventilation Solutions
Externally Mounted Fans
Heat ‘n Light 2 (excludes fan)
Shower Fan Low Profile 150
NEW
NEW
PROVEN: Trusted Locally, Proven Globally.
RELIABLE: Durable Ball Bearing Motors with a 5 Year Warranty.
SOLUTIONS: A Complete Range of Fans, Ducting and Accessories.
Thomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans.MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites, laundries and kitchens.
National Support Centre
Phone: 1300 666 595
Fax: 1300 666 594
Email: [email protected]
www.manrose.com.au
Suite 3, Level 7, 3 Rider Boulevard Rhodes NSW 2138
Western AustraliaUnit 2, 22 Hammond Rd Cockburn Central WA 6164
Victoria2/13-15 Brough St Springvale VIC 3171
TasmaniaElectrical Agencies 4 Linear Court Moonah TAS 7009
South Australia86A Richmond Rd Keswick SA 5035
Queensland26 Turbo Drive Cooparoo QLD 4151
NewcastleNick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au
PUB0385 iss02 06/11
Contents
VENTILATION SELECTION/ REGULATIONS
3 - 9
SELECTION CHART 10 - 11
VENTILATION INTRODUCTION 2
VENTILATION FANS 12 - 30
Wall Ceiling Fans 12 - 14
Thru Wall Fan Kit 15 - 16
Window Fans 17
Heat/Fan/Light Units 18
In-Line Fan Kits 19 - 21
In-Line Fans 22 - 24
Wall Mounted Fans 25
Thru Roof Fans 26
Specialised Fans 27 - 28
Fan Accessories 29 - 30
DUCT & FITTINGS 31 - 45
Ducting 31 - 33
Duct Fittings 34 - 37
Grilles & Diffusers 38 - 42
Thru Roof Cowls/Kits 43
Rangehood Ducting Kits 44
Duct Accessories 45
HEAT TRANSFER 46 - 49
TECHNICAL DATA 50 - 81
INDEX 82 - 84
NOTES 85 - 87
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au2
1
Ventilation IntroductionThomas & Betts are proud to be the distributor of the MANROSE range of ventilation fans.
Thomas and Betts have been supplying the electrical wholesale market for over 35 years and credit their success to outstanding delivery and customer service capabilities and are proud of their strong, long-standing partnerships. They represent the highest quality and most innovative products available.
The MANROSE brand is known for proven, reliable solutions with an evolving product range to meet the demands of the market. Thomas & Betts and MANROSE have a strong relationship, which has seen ventilation products developed specifically for the Australian market with features demanded by the customer.
Examples of this are developments in fan reliability; as fan performance is a critical factor, all MANROSE branded products are supplied with ball bearing motors to ensure these fans perform consistently over many years. As a result highly demanded MANROSE fans are supported by a 5 year warranty. (as marked throughout the catalogue)
Within the MANROSE range there are several models available; from a Classic model which offers trusted performance to the Pro-Series models with higher specifications. The Pro-Series brand includes products that offer installation advantages and features to the contractor, as well as sought after aesthetics demanded by the consumer. The policy of ongoing investment in product development has been a key force in driving the MANROSE brand to the forefront of the ventilation market.
MANROSE have an extraction solution for every application. Continual development and innovation ensures that future market demands are not only met but exceeded!
®
Proven Reliable Ventilation Solutions
CLASSIC
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 3
• New building materials and construction methods are effectively resulting in “waterproof” buildings. They trap moisture inside just as effectively as they keep moisture out.
• Open doors and windows provide air circulation and ventilation but security considerations mean that we are increasingly less likely to use this option. Houses tend to remain closed up more and more.
• Poor ventilation results in a consistent buildup of moisture generated by cooking/bathing-showering/clothes washing-drying/LPG gas heating/etc.
Why you need Ventilation?
Ventilation Selection
Trapping Moist Air Inside = Unhealthy Home
Problems Caused by Poor Ventilation
• Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack of ventilation around the house as well as a damp atmosphere.
• All these problems cause an avoidable level of discomfort as well as the risk of respiratory illness and general poor health.
• Problems also occur when steam from the kitchen or bathroom finds cooler surfaces around the house on which to condense. Warm, moisture-laden air condenses on cold surfaces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see.
• Moisture you cannot see is still present in the atmosphere and will be absorbed into fabrics, wall linings, bedding, etc. Attempts to conserve heat by sealing windows - and therefore reducing natural ventilation - makes this problem even worse.
• Condensation can cause considerable problems from peeling wallpaper and mould growth to severe long term structural damage to building materials.
Moisture Generators:
KitchenToiletBathroom Showering Gas HeatingCondensation Laundry
Ventilate Outside = Healthy Home
In dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly into the roof space is not permitted under the Building Code.
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au4
Ventilation Selection
Fan Placement • Careful location of an extraction fan will ensure
maximum air-flow through the room. Air extracted from a bathroom, for example, can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door. This ensures that fresh air is being drawn into the entire house at regular periods.
• Switching the fan on before starting showering or cooking sets up effective air-flows before the associated condensation problems occur. Closing doors to adjacent living areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door to replace extracted air.
Use a door vent if necessary.
• For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room. e.g. air in = air out.
• An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at the bottom), you may need to fit a through-door grille (see duct accessories) to allow replacement air into the room.
MEDIUM CIRCULATION
BEST CIRCULATION
Your Ventilation Solutions
POOR CIRCULATION
• It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other parts of the house. Use ducted fans, through-wall fans or window fans at all times. Do NOT use ceiling fans which discharge into the ceiling cavity - this only moves the problem. Moisture will permeate insulation and ceiling linings causing further problems.
• In particular with bathrooms think in terms of “room-conditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets. Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel. Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.
Fresh air in Damp
air outAirf ow throughout the hous
e
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 5
Australian Building Code Paragraph 3.8.5.0 states:Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS 1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary compartment or bathroom must:
(a) Exhaust directly to outside the building by way of ducts; or(b) Exhaust into the roof space provided:i. It is adequately ventilated by open eaves, and/or roof vents; orii. The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles.As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents.
The Manrose range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the latest building code. Natural Ventilation for the above is acceptable as long as opening windows in each room have an area of 5% or more of the floor area of the room.
What the law states
Fan Regulations
Ventilation Selection
AS1668 (summarised):“...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces; poisonous or flammable fumes and gases...”
BathroomsThe regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed
ToiletsThe regulations require a fan capable of a minimum extraction capacity of 25 litres per second when installed
KitchensThe regulations require a fan capable of a minimum extraction capacity of 50 litres per second when installed
LaundriesThe regulations require a fan capable of a minimum extraction capacity of 20 litres per second when installed
KitchenToiletBathroom Showering Gas HeatingCondensation Laundry
BCA Compliance to AS/NZ 1530 Part 3
Requirements are:Internal Surface: Spread of flame not >0 Smoke Developed not >3External Surface: Spread of flame not >7 Smoke developed not >5AS/NZS 1530 Part 3This is the Australian standard 1530, method for fire tests on building materials components and structures.
“Simultaneous determination of ignitability, flame propagation, heat release and smoke release”
Duct Standards
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au6
1. Litres/Second (l/s)
2. Cubic Metres/Hour (m³/hr) (Note: 1m3 = 1000 Litres).
3. ACH (Air changes per hour).
The number of times the total room volume of air is changed each hour.
Refer to the table below for the recommended Air Changes per hour based on the room type.
Application Description Air Changes Per Hour
Bathrooms 11 - 15
Kitchens - (private) 15 - 20
Laundries - (no drier) 6 - 10
Laundries - (with drier) 10 - 30
Toilets 6 - 10
Bedroom 2 - 5
Offices 6 - 10
Cafés 10 - 12
Canteens 8 - 12
Garages 6 - 8
Kitchens - (commercial) 20 - 30
Restaurants 8 - 12
Factories 8 - 10
Stores & Warehouses 3 - 6
Libraries 3 - 5
Classroom 5 - 7
Calculating Fan Performance
To convert from one to other types of measurement:
If you know Litres/Second (l/s): l/s x 3.6 = m³/hr. (e.g. 25 l/s x 3.6 = 90m³/hr)
If you know Cubic Metres/Hour (m³/hr): m³/hr ÷ 3.6 = l/s (e.g. 200m³/hr ÷ 3.6 = 55.55 l/s)
milk1 litre
1m1m
1m
4. Working out the right fan for the job
1. Calculate the room volume in metres (L x W x H)2. Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit.3. The result is the total performance required in cubic metres per hour.
Select a fan with a higher performance than this figure.
For Example: What is the best fan for a bathroom that is 2.8m long by 2.8m wide with a ceiling height of 2.4m?
1. Calculate the volume of the bathroom: 2.8 x 2.8 x 2.4 = 18.8m3
2 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m³/hr
3. The fan to choose for this bathroom would be a fan that performs at greater than 282m³/hr. A fan that has a performance level of 313m³/hr or higher (eg. XP150, or SF150) would do this job
Ventilation Selection
400
350
300
250
200
150
100
50
0
110
100
90
80
70
60
50
40
30
20
10
240
220
200
180
160
140
120
100
80
60
40
20
m3/hr l/s cfm
Quick Cross-Reference Calculations Known To Find Action l/s m³/hr l/s x 3.6 =m³/hr m³/hr l/s m³/hr ÷ 3.6 = l/s cfm m³/hr cfm x 1.69 =m³/hr cfm l/s cfm x 0.47 = l/s
m³/hr to l/s to cfm Comparison Chart
5. Converting measurements
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 7
Compare Centrifugal Against Axial Fan Performance:
1. SF100 (axial) vs an SF200 (centrifugal) fan The starting point is the free air performance of
23l/s for the axial and 31l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases volume of air moved. From the below example you can see that at 20Pa of pressure the 100mm axial fan airflow has stopped whereas the 100mm centrifugal fan is still moving 29l/s!
Simple facts:1. Fan size (i.e diameter of impeller & outlet)2. Duct and the way it is installedSmaller duct = greater resistance to airflow.More bends = greater resistance to airflow.Longer duct runs = increasingly reduced airflow.
Wrinkled ducting causes turbulence and reduces airflow
Smoother, extended ducting allows smooth, increased airflow
3. Fan type
SF100 & SF200 PERFORMANCE GRAPH
2. ID150 (axial) vs a MAN150 (centrifugal) fan The starting point is the free air performance of
89l/s for the axial and 115l/s for the centrifugal. As duct is added to each of these fans, this increases the pressure (Pa) and decreases the volume of air moved. From the below example you can see that at 120Pa of pressure the 150mm axial fan airflow has stopped whereas the 150mm centrifugal fan is still moving 102l/s!
ID150 & MAN150 PERFORMANCE GRAPH
Centrifugal Flow:Pressure developing fans which achieve good flow against the resistance created in a ducted system. Particularly useful in venting areas like internal bathrooms/laundries, multi-room extraction systems, heat-transfer systems, etc.
Mix Flow:Powerful in-duct mounted fans, designed for applications that require high air flows, with low relative noise.
Axial Flow:Suitable for wall, window and roof applications where they can extract directly to the outside. Short duct runs are an option but the length of duct should be limited.e.g. 100mm dia : 2-3m length 125mm dia : 3-4m length 150mm dia : 4-5m length
WRINKLED DUCT AIRFLOW
SMOOTH DUCT AIRFLOW
What Affects Performance?
SF200
SF100
50
150
100
200
250
300
0 20 40 60 80 100 120 140
5
15
10
20
25
30
0 72 144 216 288 360 432 504
MAN150
ID150
Manrose ALUDUCT flexible ducting retains its stretched-out shape (for smooth airflow) far better than most competitive products. Many competitive ducts tend to shrink back on themselves, wrinkling the duct fabric.
Ventilation Selection
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au8
Location of your ventilation fan will depend on the physical constraints of your room. The visual recognition guide (shown on the right) will help you decide the most suitable physical installation to meet your requirements.
Within the above mounting options there are various other features available, such as : • TIMER(maintain fan run-on after the room is
vacated)
• PULLCORD(Switch at fan, instead of light switch control)
• AUTO-SHUTTER(electrically operated shutters inside the fan - closed when the fan is not running to stop draughts).
• PIRSENSOR(provide automatic motion-sensor control of fans)
Fan Applications
Wet Areas & Recommended Fan Types
When considering where in the room to place an extractor fan, you must consider the wet areas.
Zone 1: This is the zone directly within the shower or bath up to 2.25 metres above the floor and 150mm around the bath/shower cubicle. A SELV fan or an ln-line fan kit will be required in this zone. For example if a fan is mounted directly over the bath or shower it must be a low voltage fan (SELV).
Zone 2: This zone is 0.6 metres horizontally outside of zone 1 and 2.25 metres above the floor.
Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally outside of zone 2 and 2.25 metres above the floor.
Zone 1: Requires a Low Voltage Fan or an In-Line fan kitZone 2: Any fan model can be usedZone 3: Any fan model can be used
- Wall/Ceiling Mounted Fans - Window Fans - Thru Wall Fan Kits - Thru Roof Fan Kits- In-Line Fan Kits - Low Voltage Fans
Shower
Low Voltage
Locate your Ventilation Fan
Ventilation Selection
How To OrderSelect the model that exhausts the closest to your requirements. If the performance required falls between two fans, it is recommended you select the one handling the most air.
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 9
Window Mounted Fan:Used in situations where an existing window fan is being replaced, or where there is no available external wall space and no ceiling space access.
Page Reference 17
Fan Application Examples
Ceiling Mounted Fan: Designed for low-pitch roofs or between floors, where there is no ceiling access. This enables the fan to be accessible for service after installation. Also available with heat lamps & lighting.
Page Reference 12 - 14 & 18
Thru Roof KitUsed where there is limited access to the roof space, or where there is no soffit available. Thru Roof Kits can be used with any extraction fan, or use a Thru Roof Fan Kit with the fan mounted within the cowl.
Page Reference 26
Thru Wall Fan Kit: Used where the bathroom is on an external wall, or there is no ceiling space for an in-line fan.
Page Reference 15 - 16
In-Line Mounted Fan Kit: Most common bathroom installation, the fan is mounted in the ceiling space with the grille directly above the source of the steam. Generally this type of installation is quieter as the fan is not directly in the room.
Page Reference 19 - 21
For technical advice phone Customer Services 1300 666 595 We are only too happy to offer advice on a custom build solution.
Ventilation Selection
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au10
Selection Chart
Selecting the Right Fan is as easy as... 1, 2, 3
Select your required application
Eg: Bathrooms(11 - 15 air changes per hour)
Calculate the volume of the room in cubic metres (m3) by multiplying the length x width x height.
Eg: 2.3m x 2.2m x 2.4m = 12.14m3
(Select a room volume 11-15m3)
Follow the 12m3 row across and select one of the fan kits available based on your mounting requirements (see top headings and photo’s)
Eg: If you require a Thru Wall Kit then you can choose any of the XP150 or XPLP150 kits
WL
HKitchenToiletBathroom Showering Gas HeatingCondensation Laundry
Wall/Ceiling Fans Thru Wall Fan Kits
Pro Series CLASSIC Pro Series CLASSIC
1-5m3 XFLP125 XF125 XPLP125 XP125
6-10m3 XFLP125 XF125 XPLP125 XP125
11-15m3 XFLP150 XF150 XPLP150 XP150
1-10m3 XFLP150 XF150 XPLP150 XP150
11-15m3 XFLP150 XF150 XPLP150 XP150
16-20m3 XFLP150 XF150 XPLP150 XP150
21-30m3 XFS230 XPS230
1-5m3 XFLP150 XF150 XPLP150 XP150
6-10m3 XFLP150 XF150 XPLP150 XP150
11-20m3 XFS230 XPS230
Room Type Room Size (m3)
- Toilets- Laundries - No drier- Cellar- Offices
These rooms require between 6 and 10 ACH(Air changes per hour)
- Bathrooms- Showers- Ensuites
- Kitchens- Laundries - With drier
These rooms requirebetween 15 and 20 ACH (Air changes per hour)
These rooms requirebetween 11 and 15 ACH (Air changes per hour)
(18) (18) (18) (18)
1 2 3
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 11
Wall/Ceiling Fans Thru Wall Fan Kits
Pro Series CLASSIC Pro Series CLASSIC
1-5m3 XFLP125 XF125 XPLP125 XP125
6-10m3 XFLP125 XF125 XPLP125 XP125
11-15m3 XFLP150 XF150 XPLP150 XP150
1-10m3 XFLP150 XF150 XPLP150 XP150
11-15m3 XFLP150 XF150 XPLP150 XP150
16-20m3 XFLP150 XF150 XPLP150 XP150
21-30m3 XFS230 XPS230
1-5m3 XFLP150 XF150 XPLP150 XP150
6-10m3 XFLP150 XF150 XPLP150 XP150
11-20m3 XFS230 XPS230
Selection Chart
Note: All selections are based on installed fan performance and maximum air change rates (figures in brackets show actual air changes stated if less than maximum)
Heat/Fan/Light Units In-Line Fan Kits Extract-A-Lite Kits Window
FansThru Roof Fan Kits
Pro Series Pro Series CLASSIC Pro Series CLASSIC CLASSIC CLASSIC
Heat ‘n Vent 2 SFLP125 SF125 ELLP125 EL100 WF150 HYPER
Heat ‘n Vent 2 SFLP125 SF125 ELLP125 EL125 WF150 HYPER
Heat ‘n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER
Heat’n Vent 2 SFLP150 SF150 ELLP125 EL150 WF150 HYPER
Heat ‘n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER
SFLP150 SF150 ELLP150 EL150 WF150 ULTRA
MFLP150 WF230 ULTRA
SFLP150 SF150 ELLP125 EL150 WF150 HYPER
SFLP150 SF150 ELLP150 EL150 WF150 HYPER
MFLP150 WF230 ULTRA
(18)
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au12
Wall/Ceiling Mounted Fans
PRO-SERIES XFLP Low Profile Models
Metric Size Model No. Switching Method
Performance Order Code
125mm XFLP125SS Standard 36l/s, 130m³/hr FAN0589
125mm XFLP125ST Timer 36l/s, 130m³/hr FAN0590
150mm XFLP150SS Standard 87l/s, 313m³/hr FAN0594
150mm XFLP150ST Timer 87l/s, 313m³/hr FAN0595
SQUARE MODELS
Metric Size Model No. Switching Method
Performance Order Code
125mm XFLP125CS Standard 36l/s, 130m³/hr FAN0604
125mm XFLP125CT Timer 36l/s, 130m³/hr FAN0605
150mm XFLP150CS Standard 87l/s, 313m³/hr FAN0609
150mm XFLP150CT Timer 87l/s, 313m³/hr FAN0610
CIRCULAR MODELS
Metric Size Model No. Switching Method
Performance Order Code
125mm XFLP125SLV SELV 12V 36l/s, 130m³/hr FAN0591
125mm XFLP125CLV SELV 12V 36l/s, 130m³/hr FAN0606
150mm XFLP150SLV SELV 12V 87l/s, 313m³/hr FAN0596
150mm XFLP150CLV SELV 12V 87l/s, 313m³/hr FAN0611
Metric Size Description - Square Order Code
125mm Satin Silver Fascia FAN2068
125mm Chrome Fascia FAN0755
150mm Satin Silver Fascia FAN2071
150mm Chrome Fascia FAN0598
ACCESSORIES
Low Voltage Models
Square Models
Circular Models
Accessories - Square & Circular Fascia
Metric Size Description - Circular Order Code
125mm Satin Silver Fascia FAN2069
125mm Chrome Fascia FAN0757
150mm Satin Silver Fascia FAN2070
150mm Chrome Fascia FAN0613
• Unique low profile design enables these fans to be installed unobtrusively into any wall or ceiling• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor • Supported by a five year warranty• For technical specification refer page 51
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402)
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
3. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 13
Wall/Ceiling Mounted Fans
CLASSIC XF Models
Commercial Models
Auto Shutter Models
Low Voltage Models
Standard Models
COMMERCIAL MODELS
Metric Size Model No. Switching Method
Performance Order Code
150mm XF150PIR PIR Control 87l/s, 313m³/hr FAN0124
230mm XFS230S Standard 152l/s, 550m³/hr FAN0374
300mm XFS300S Standard 306l/s, 1100m³/hr FAN2040
AUTO SHUTTER MODELS
Metric Size Model No. Switching Method
Performance Order Code
150mm XF150A Standard 87l/s, 313m³/hr FAN0121
150mm XF150AP Pull Cord 87l/s, 313m³/hr FAN0122
150mm XF150AT Timer 87l/s, 313m³/hr FAN0123
230mm XFS230A Standard 152l/s, 550m³/hr FAN0346
300mm XFS300A Standard 306l/s, 1100m³/hr FAN2041
Metric Size Model No. Switching Method
Performance Order Code
100mm XF100LV SELV 12V 23l/s, 85m³/hr FAN0044
125mm XF125LV SELV 12V 36l/s, 130m³/hr FAN0071
150mm XF150LV SELV 12V 87l/s, 313m³/hr FAN0119
Metric Size Model No. Switching Method
Performance Order Code
100mm XF100S Standard 23l/s, 85m³/hr FAN0046
100mm XF100P Pull Cord 23l/s, 85m³/hr FAN0047
100mm XF100T Timer 23l/s, 85m³/hr FAN0048
125mm XF125S Standard 36l/s, 130m³/hr FAN0072
125mm XF125P Pull Cord 36l/s, 130m³/hr FAN0074
125mm XF125T Timer 36l/s, 130m³/hr FAN0075
150mm XF150S Standard 87l/s, 313m³/hr FAN0120
150mm XF150P Pull Cord 87l/s, 313m³/hr FAN0126
150mm XF150T Timer 87l/s, 313m³/hr FAN0127
STANDARD MODELS
• Designed for wall or ceiling mounting, these models are efficient and easy to install • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor• Supported by a five year warranty • For technical specification refer page 52 & 57
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pullcord switch on fan.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.5. PIR Model - Motion sensor incorporated in fan.6. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au14
Wall/Ceiling Mounted Fans
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.3. PIR Model - Motion sensor incorporated in fan. Range up to 5 metres.
CLASSIC CF Multi-Vent Models
CLASSIC CF Models
DESIGNER Ceiling Fan Models
• Designed for apartments where space is limited, these ceiling mounted fans can be installed in confined spaces
• The centrifugal fan design is ‘whisper quiet’ in operation • Supported by a two year warranty• For technical specification refer page 53
Metric Size Model No. Switching Method
Performance Order Code
100mm WVC100W Standard 63l/s, 225m³/hr FAN0884
100mm WVC100S Standard 63l/s, 225m³/hr FAN0885
FLUSH FITTING RANGE
Metric Size Model No. Switching Method
Performance @ Speed 3
Order Code
100mm FFCF234S Standard 65l/s, 234m³/hr FAN0038
100mm FFCF234T Timer 65l/s, 234m³/hr FAN0499
100mm FFCF234PIR PIR 65l/s, 234m³/hr FAN0501
SURFACE MOUNT RANGE
Metric Size Model No. Switching Method
Performance @ Speed 3
Order Code
100mm SMCF234S Standard 65l/s, 234m³/hr FAN0504
100mm SMCF234T Timer 65l/s, 234m³/hr FAN0505
• Designed for apartments where space is limited, with a choice of wall or ceiling mounted system
• These Models include centrifugal fans with a choice of three in-built speed settings depending on the performance required
• Supported by a two year warranty• For technical specification refer page 53
Metric Size Model No. Switching Method
Performance @ Speed 1
Order Code
100mm CF200S Standard 31l/s, 110m³/hr FAN0041
100mm CF200TP Timer 31l/s, 110m³/hr FAN0042
• Designed to move air over long distances• The centrifugal fan design provides efficient airflow and quiet operation• Supported by a two year warranty• For technical specification refer page 53
NOTE: All fan flow rates quoted are free air delivery.
Year Warranty
Year Warranty
Year Warranty
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 15
Thru Wall Fan Kits
PRO-SERIES XPLP Low Profile Models
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
Metric Size Model No. Switching Method
Performance Order Code
125mm XPLP125SS Standard 36l/s, 130m³/hr FAN0614
125mm XPLP125ST Timer 36l/s, 130m³/hr FAN0615
150mm XPLP150SS Standard 87l/s, 313m³/hr FAN0621
150mm XPLP150ST Timer 87l/s, 313m³/hr FAN0623
STANDARD MODELS
Standard Models
Accessories - Square & Circular Fascia
Low Voltage Models
Metric Size Model No. Switching Method
Performance Order Code
125mm XPLP125SLV SELV 12V 36l/s, 130m³/hr FAN0620
125mm XPLP125CLV SELV 12V 36l/s, 130m³/hr FAN0735
150mm XPLP150SLV SELV 12V 87l/s, 313m³/hr FAN0732
150mm XPLP150CLV SELV 12V 87l/s, 313m³/hr FAN0738
• The unique Low Profile design enables these fans to be installed unobtrusively into any wall (requires a minimum wall cavity of 110mm)• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor• Supported by a five year warranty • For technical specification refer page 54
Metric Size Description - Square Order Code
125mm Satin Silver Fascia FAN2068
125mm Chrome Fascia FAN0755
150mm Satin Silver Fascia FAN2071
150mm Chrome Fascia FAN0598
ACCESSORIES
Metric Size Description - Circular Order Code
125mm Satin Silver Fascia FAN2069
125mm Chrome Fascia FAN0757
150mm Satin Silver Fascia FAN2070
150mm Chrome Fascia FAN0613
3. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au16
Thru Wall Mounted Fan Kits
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
3. Pull Cord Model - Integral pullcord switch on fan.4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.5. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.
CLASSIC XP Models
Auto Shutter Models
Standard Models
Low Voltage Models
Metric Size Model No. Switching Method
Performance Order Code
100mm XP100S Standard 23l/s, 85m³/hr FAN0053
100mm XP100P Pull Cord 23l/s, 85m³/hr FAN0054
100mm XP100T Timer 23l/s, 85m³/hr FAN0055
125mm XP125S Standard 36l/s, 130m³/hr FAN0080
125mm XP125P Pull Cord 36l/s, 130m³/hr FAN0082
125mm XP125T Timer 36l/s, 130m³/hr FAN0083
150mm XP150S Standard 87l/s, 313m³/hr FAN0135
150mm XP150P Pull Cord 87l/s, 313m³/hr FAN0140
150mm XP150T Timer 87l/s, 313m³/hr FAN0141
STANDARD MODELS
AUTO SHUTTER MODELS
Metric Size Model No. Switching Method
Performance Order Code
150mm XP150A Standard 87l/s, 313m³/hr FAN0136
150mm XP150AP Pull Cord 87l/s, 313m³/hr FAN0137
150mm XP150AT Timer 87l/s, 313m³/hr FAN0138
230mm XPS230A Standard 152l/s, 550m³/hr FAN0348
300mm XPS300A Standard 306l/s, 1100m³/hr FAN2043
• These fans are designed to be ducted straight through an exterior wall and are efficient and easy to install • These axial fans have been upgraded with ball bearing motors to prolong the life of the motor • Supported by a five year warranty • For technical specification refer page 55 & 57
Metric Size Model No. Switching Method
Performance Order Code
100mm XP100LV SELV 12V 25l/s, 85m³/hr FAN0409
125mm XP125LV SELV 12V 36l/s, 130m³/hr FAN0410
150mm XP150LV SELV 12V 87l/s, 313m³/hr FAN0411
Commercial Models
COMMERCIAL MODELS
Metric Size Model No. Switching Method
Performance Order Code
230mm XPS230S Standard 152l/s, 550m³/hr FAN0455
300mm XPS300S Standard 306l/s, 1100m³/hr FAN2042
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 17
Standard Models
Standard Larger Models
CLASSIC WF Models
CLASSIC COM Models
Window Mounted Fans
Commercial Auto Shutter Models
Metric Size Model No. Switching Method
Performance Order Code
100mm WF100P Pull Cord 23l/s, 85m³/hr FAN0021
100mm WF100PLV Low Voltage 23l/s, 85m³/hr FAN0452
STANDARD MODELS
Metric Size Model No. Switching Method
Performance Order Code
150mm WF150MP Pull Cord 87l/s, 313m³/hr FAN0110
150mm WF150MPLV SELV 12 87l/s, 313m³/hr FAN0355
Auto Shutter Models
AUTO SHUTTER MODELS
Metric Size Model No. Switching Method
Performance Order Code
150mm WF150AP Pull Cord 87l/s, 313m³/hr FAN0107
150mm WF150APT Pull Cord Timer 87l/s, 313m³/hr FAN0109
230mm WF230AP Pull Cord 152l/s, 550m³/hr FAN0146
300mm WF300A Standard 306l/s, 1100m³/hr FAN0482
COMMERCIAL AUTO SHUTTER MODELS
Metric Size Model No. Switching Method
Performance Order Code
230mm COM230A Standard 185l/s, 670m³/hr FAN0519
230mm COM230MP Standard 185l/s, 670m³/hr FAN0518
300mm COM300A Standard 280l/s,1020m³/hr FAN0521
300mm COM300MP Standard 280l/s,1020m³/hr FAN0520
• Designed for use in situations where an existing window fan is being replaced or where there is no available external wall space or ceiling space access
• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor and are supported by a five year warranty
• For technical specification refer page 56 & 58
MANUAL SHUTTER MODELS
Metric Size Model No. Switching Method
Performance Order Code
230mm WF230P Pull Cord 152l/s, 550m³/hr FAN0148
300mm WF300P Pull Cord 306l/s, 1100m³/hr FAN0481
STANDARD LARGER MODELS
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. 3. Pull Cord Model - Integral pullcord switch on fan.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.5. Manual Pullcord - Pullcord operates fan and manual shutters.6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3. NOTE: All fan flow rates quoted are free air delivery.
• Designed for commercial applications such as pubs, restaurants, hotels, shops etc • These axial fans include ball bearing motors to prolong the life of the motor• Supported by a five year warranty • For technical specification refer page 58
Ball
Bear
ing Motor
Year Warranty
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402)
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au18
Ball
Bear
ing Motor
Year Warranty
PRO-SERIES Heat ‘n Vent Models
CLASSIC 2 Heat ‘n Light
CLASSIC Heat ‘n Vent 2
Heat/Fan/Light Kits
Metric Size Model No. Performance Order Code
125mm Heat ‘n Vent 4 60l/s, 216m³/hr FAN0995
125mm Heat ‘n Vent 2 50l/s, 180m³/hr FAN0940
ACCESSORIES
Metric Size Description Order Code
125mm Heat ‘n Vent 4 Silver Fascia FAN1015
125mm Heat ‘n Vent 2 Silver Fascia FAN1014
275W Heat Lamp LHT0081
50W Halogen GU10 lamp LHT0140
• With a 40% increase in performance* these systems meet the demands of larger bathrooms and the stylish fascia blends into the decor
• These high efficiency centrifugal fans incorporate a unique anti- condensate design feature
• Supported by a five year warranty • For technical specification refer page 59
Metric Size Model No. Performance Order Code
100mm Heat ‘n Vent 2 35l/s, 126m³/hr FAN2162
Metric Size Description Order Code
100mm 2 Heat ‘n Light (excludes fan) FAN2200
• This system delivers instant heat combined with ventilation and soft lighting to create a comfort area in small bathrooms
• Supported by a five year warranty • For technical specification refer page 59
• This system provides instant heat and additional lighting• For a complete bathroom solution an extraction fan can be added• Supported by a five year warranty • For technical specification refer page 59
Switching Options:1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted with 3 metres of duct, one bend and one external grille (normal installation).* Increase in performance is based on the comparison to the previous models.
Pro-Series Heat ‘n Vent 4
Pro-Series Heat ‘n Vent 2
NEW
Classic Heat ‘n Vent 2
2 Heat ‘n Light
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 19
CLASSIC SF Shower Fan Models
In-Line Mounted Fan Kits
PRO-SERIES SFLP Shower Fan Models
PRO-SERIES MIXFLO™ Shower Fan ModelsMetric Size Model No. Switching
MethodPerformance Order Code
100mm MFLP100S Standard 69l/s, 250m³/hr FAN2049
125mm MFLP125S Standard 89l/s, 320m³/hr FAN2050
150mm MFLP150S Standard 156l/s, 560m³/hr FAN2051
• These powerful inline mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels
• Supported by a five year warranty• For technical specification refer page 60
Metric Size Model No. Switching Method
FanType
Performance Order Code
125mm SFLP125S Standard Ctr’fgl 39l/s, 140m³/hr FAN0616
125mm SFLP125T Timer Ctr’fgl 39l/s, 140m³/hr FAN0617
150mm SFLP150S Standard Whisp 94l/s, 340m³/hr FAN0618
150mm SFLP150T Timer Whisp 94l/s, 340m³/hr FAN0619
Metric Size Model No. Switching Method
FanType
Performance Order Code
100mm SF100S Standard Axial 23l/s, 85m³/hr FAN0017
100mm SF100T Timer Axial 23l/s, 85m³/hr FAN0018
100mm SF200S Standard Ctr’fgl 31l/s, 110m³/hr FAN0328
100mm SF200T Timer Ctr’fgl 31l/s, 110m³/hr FAN0329
125mm SF125S Standard Axial 36l/s, 130m³/hr FAN0064
125mm SF125T Timer Axial 36l/s, 130m³/hr FAN0065
150mm SF150S Standard Axial 87l/s, 313m³/hr FAN0101
150mm SF150T Timer Axial 87l/s, 313m³/hr FAN0102
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require three wires: permanent phase, switched phase, neutral.NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.
• These high efficiency inline fans are designed to provide higher levels of extraction for today’s larger bathrooms
• Supported by a five year warranty• For technical specification refer page 61
• With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from source • These fans have been upgraded with ball bearing motors to prolong the life of the motor • Supported by a five year warranty • For technical specification refer page 62
SFLP150
MKLP150
SF150
For the ensuite
Complete Bathroom Ventilation Solutions
FOR THE BATHROOMDesigned for the main bathroom to give more warmth & increased extraction, Heat 'n Vent 4 is the ultimate in heat/fan/light units. Includes 3m of ducting.Heat 'n Vent 4 (FAN0995)
FOR THE BATHROOMHigh performance extraction incorporated with a quality halogen downlight that mounts directly above the steam source. 150mm Extract-a-Lite Fan Kit (FAN0803)
FOR THE ENSUITEStylish and efficient, the compact design of the Heat 'n Vent 2 makes it the heat/fan/light solution for ensuites.Includes 3m of ducting.Heat 'n Vent 2 (FAN0940)
FOR THE ENSUITEComplete ventialtion solution as steam is drawn directly from source to provide efficient ventilation of the room 150mm Shower Fan Kit (FAN0101)
MANROSE SOLUTIONS...backed by an industry leading 5 year warranty.
For a healthier home these high performance systems remove steam & moisture and exhaust directly outside
In dwellings with a metal roof or where the roof is lined with sarking, ventilating directly into the roof space is not permitted by the Building Code unless the roof space is adequately ventilated by open eaves or roof vents.
(see Paragraph 3.8.5.0 of Australian Building Code)
Proudly distributed by:
5FIVE YEAR WARRANTY
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au20
In-Line Mounted Fan Kits
PRO-SERIES ELLP Extract-a-lite Low Profile Models
Metric Size Model No. Switching Method
Performance Order Code
125mm ELLP125WS - Wht Standard 39l/s, 140m³/hr FAN2029
125mm ELLP125WT - Wht Timer 39l/s, 140m³/hr FAN2031
125mm ELLP125SS - Slv Standard 39l/s, 140m³/hr FAN2030
125mm ELLP125ST - Slv Timer 39l/s, 140m³/hr FAN2032
150mm ELLP150WS - Wht Standard 94l/s, 340m³/hr FAN2033
150mm ELLP150WT - Wht Timer* 94l/s, 340m³/hr FAN2035
150mm ELLP150SS - Slv Standard 94l/s, 340m³/hr FAN2034
150mm ELLP150ST - Slv Timer* 94l/s, 340m³/hr FAN2036
• These high efficiency inline fans are designed to provide higher levels of extraction for larger bathrooms and include a stylish downlight
• White or satin silver finish available to complement your bathroom decor• Electronic Transformer included in the kit to operate the 12V downlight• Supported by a five year warranty• For technical specification refer page 63
* Includes a 7 minute fixed timer
Metric Size Description Order Code
125mm Pro Series ELLP Diffuser White incl lamp DCT1519
125mm Pro Series ELLP Diffuser Silver incl lamp DCT1520
150mm Pro Series ELLP Diffuser White incl lamp DCT1521
150mm Pro Series ELLP Diffuser Silver incl lamp DCT1522
12V 35-50W dichroic lamp with 60˚ angle beam FAN0431
Electronic Transformer 12VAC 50kHz FAN2101
ACCESSORIES
NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. The 100 and 125mm models are adjustable between 1-20 minutes, whereas the 150mm models include a fixed 7 minute timer. Both require three wires: permanent phase, switched phase, neutral.
ELLP150SS
ELLP125SW
125mm ELLP Diffusers
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 21
CLASSIC EL Extract-a-lite Models
In-Line Mounted Fan Kits
Metric Size Description Order Code
100mm EL Diffuser white incl lamp DCT0360
100mm EL Diffuser chrome incl lamp DCT0362
125mm EL Diffuser white incl lamp DCT2121
125mm EL Diffuser chrome incl lamp DCT2120
150mm EL Diffuser white incl lamp DCT1169
150mm EL Diffuser chrome incl lamp DCT1171
100mm Accessory chrome bezel - Extract-a-lite DCT0366
125mm Accessory chrome bezel - Extract-a-lite FAN2076
150mm Accessory chrome bezel - Extract-a-lite FAN0827
12V 35-50W dichroic lamp with 60˚ angle beam FAN0431
Electronic Transformer 12VAC 50kHz FAN2101
ACCESSORIES
Metric Size Model No. Switching Method
Performance Order Code
100mm EL100S Standard 31l/s, 110m³/hr FAN0420
100mm EL100T Timer 31l/s, 110m³/hr FAN0438
125mm EL125S Standard 36l/s, 130m³/hr FAN2037
125mm EL125T Timer 36l/s, 130m³/hr FAN2038
150mm EL150S Standard 87l/s, 313m³/hr FAN0803
150mm EL150T Timer 87l/s, 313m³/hr FAN0804
• The fan is mounted in the ceiling space, and is therefore able to draw steam directly from source, while at the same time providing spot lighting within your bathroom
• These fans have been upgraded with ball bearing motors to prolong the life of the motor• Electronic Transformer included in the kit to operate the 12V downlight• Supported by a five year warranty • For technical specification refer page 64
NOTE: All fan flow rates quoted are free air delivery. Performance will be affected by the length of ducting used.
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off. Adjustable between 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
125mm EL Diffusers
EL150S
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au22
In-Line Duct Mounted Fans
PRO-SERIES WhisperVent Models
CLASSIC Hyper150™ Models
Metric Size Model No. Switching Method
Performance Order Code
150mm WVI150 Standard 94l/s, 340m³/hr FAN0916
• This high efficiency inline fan is designed to provide higher levels of extraction with low relative noise
• The ball bearing motor prolongs the life of the motor• Supported by a five year warranty• For technical specification refer page 65
Metric Size Model No. Switching Method
Performance Order Code
150mm Hyper150 Standard 89l/s, 320m³/hr FAN0085
Switching Options:1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted are free air delivery.
• This high efficiency inline fan is designed to provide high levels of extraction• The ball bearing motor prolongs the life of the motor• Supported by a five year warranty• Includes 1.3m lead and 3 pin plug• For technical specification refer page 65
PRO-SERIES MIXFLO™ Fan ModelsMetric Size Model No. Switching Method Performance @
High SpeedOrder Code
100mm MF100S Standard 2 Speed 69l/s, 250m³/hr FAN1004
100mm MF100T Timer 2 Speed 69l/s, 250m³/hr FAN2124
100mm MF100PL Plug & Lead 2 Speed 69l/s, 250m³/hr FAN1050
125mm MF125S Standard 2 Speed 89l/s, 320m³/hr FAN1005
125mm MF125T Timer 2 Speed 89l/s, 320m³/hr FAN2125
125mm MF125PL Plug & Lead 2 Speed 89l/s, 320m³/hr FAN1051
150mm MF150S Standard 2 Speed 156l/s, 560m³/hr FAN1006
150mm MF150T Timer 2 Speed 156l/s, 560m³/hr FAN2126
150mm MF150PL Plug & Lead 2 Speed 156l/s, 560m³/hr FAN1048
200mm MF200S Standard 3 Speed 253l/s, 910m³/hr FAN1007
200mm MF200T Timer 2 Speed 253l/s, 910m³/hr FAN2127
200mm MF200PL Plug & Lead 3 Speed 253l/s, 910m³/hr FAN1053
• These powerful inline mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels
• Supported by a four year warranty or 30,000 continuous hours• For technical specification refer page 60
30,00
0 HOURS
Year Warranty 4
Ball
Bear
ing Motor
Year Warranty
Ball
Bear
ing Motor
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 23
In-Line Mounted Fans
CLASSIC CFD Models
Metric Size Model No. Switch Method Performance Order Code
100mm CFD200S Standard 31l/s, 110m³/hr FAN0326
100mm CFD200T Timer 31l/s, 110m³/hr FAN0327
125mm CFD225S Standard 39l/s, 140m³/hr FAN2067
125mm CFD225T Timer 39l/s, 140m³/hr FAN2066
CLASSIC ID Models
Metric Size Model No. Switching Method
Performance Order Code
100mm ID100S Standard 23l/s, 85m³/hr FAN0012
100mm ID100T Timer 23l/s, 85m³/hr FAN0013
125mm ID125S Standard 36l/s, 130m³/hr FAN0060
125mm ID125T Timer 36l/s, 130m³/hr FAN0061
150mm ID150S Standard 87l/s, 313m³/hr FAN0090
150mm ECO150S Standard 64l/s, 230m³/hr FAN2078
150mm ID150T Timer 87l/s, 313m³/hr FAN0091
230mm ID230S Standard 152l/s, 550m³/hr FAN0405
230mm ID230T Timer 152l/s, 550m³/hr FAN0406
• With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from source
• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor • Supported by a five year warranty• For technical specification refer page 66
• These high efficiency centrifugal fans are designed for use where longer duct runs are required.
• The ball bearing motor prolongs the life of the motor • Supported by a five year warranty• For technical specification refer page 67
Switching Options:1. Standard Model - operates from remote switch (not supplied).2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
NOTE: All fan flow rates quoted are free air delivery.
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au24
High Performance Centrifugal 3 Speed Models
In-Line Mounted Fans
High Performance Centrifugal Models
WhisperVent Low Profile Centrifugal Models
Metric Size Model No. Performance @ Speed 3 Order Code
150mm 3 Speed 115l/s, 415m³/hr FAN0921
200mm 3 Speed 208l/s, 750m³/hr FAN0997
Metric Size Model No Performance Order Code
100mm MAN100 49l/s, 176m³/hr FAN0361
125mm MAN125 61l/s, 220m³/hr FAN0360
150mm MAN150 115l/s, 415m³/hr FAN0330
200mm MAN200 208l/s, 750m³/hr FAN0467
250mm MAN250 280l/s, 1010m³/hr FAN0358
315mm MAN315 360l/s, 1300m³/hr FAN0357
• Suitable for a variety of domestic and commercial applications, these inline centrifugal fans provide extremely high performance with a choice of sizes
• Supported by a two year warranty• For technical specification refer page 68
Switching Options:1. Standard Model - operates from remote switch (not supplied).NOTE: All fan flow rates quoted are free air delivery.
Metric Size Model No Performance Order Code
150mm WVILP150-1 124l/s, 445m³/hr FAN0829
150mm WVILP150-3 118l/s, 425m³/hr FAN0830
• Suitable for a variety of domestic and commercial applications, these inline centrifugal fans provide high performance at your pre-set choice of speed
• Supported by a two year warranty• For technical specification refer page 69
• Suitable for a variety of domestic and commercial applications, this inline centrifugal fan offers high performance with a low profile design to enable this unit to be installed in confined spaces
• Supported by a two year warranty• For technical specification refer page 70
Year Warranty
Please note: Can be used for supply/extract
Please note: Can be used for supply/extract
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 25
Year Warranty
Externally Mounted Fans - Extract
Wall Mounted Fans
Externally Mounted Fans - 3 Speed Extract
Metric Size Fan Type Air Performance Order Code
150mm Axial Extract 73l/s, 263m3hr FAN2303
150mm Ctr’fgl (190 Motor) Extract 109l/s, 392m3hr FAN2301
150mm Ctr’fgl (220 Motor) Extract 133l/s, 480m³/hr FAN2302
Metric Size Fan Type Air Performance
(High Speed)
Order Code
150mm Ctr’fgl (190 Motor) Extract 113l/s, 408m3hr FAN2316
150mm Ctr’fgl (220 Motor) Extract 136l/s, 493m³/hr FAN2317
• Designed for use in residential and light commercial applications where a high performance, low noise solution is required
• Specific applications include apartments where space is limited
• Supported by a two year warranty• For technical specification refer page 71
NOTE: All fan flow rates quoted are free air delivery.
Connection:1. Electrical connection must be made internally (Junction Box is only suitable for internal use).
• Designed for use in residential and light commercial applications where a high performance, low noise solution is required
• Three speed models enable further flexibility in a variety of applications• Specific applications include apartments where space is limited• Supported by a two year warranty• For technical specification refer page 71
NEW
NEW
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au26
Thru Roof Fan Cowl Models
Thru Roof Fan System Models
Thru Roof Mounted Fans
Thru Roof Fan Models with Dektite & HDPE Tube
Metric Size Fan Type Air Performance* Order Code
150mm Ctr’fgl Extract 130l/s, 468m³/hr FAN0529
150mm Ctr’fgl 3-spd Extract 130l/s, 468m³/hr FAN1002
150mm Axial - Whisper Extract 89l/s, 320m³/hr FAN1009
150mm Axial Extract 80l/s, 288m³/hr FAN0531
150mm Axial Supply 80l/s, 288m³/hr FAN0533
Metric Size Fan Type Air Performance* Order Code
150mm Ctr’fgl Extract 130l/s, 468m³/hr FAN0530
150mm Ctr’fgl 3-spd Extract 130l/s, 468m³/hr FAN0967
150mm Axial - Whisper Extract 89l/s, 320m³/hr FAN1060
150mm Axial Extract 80l/s, 288m³/hr FAN0532
150mm Axial Supply 80l/s, 288m³/hr FAN0534
Metric Size Description Fan Type Performance* Order Code
150mm Ultra Ctr’fgl 130l/s, 468m³/hr FAN0535
150mm Hyper Hyper 89l/s, 320m³/hr DCT0189
• High quality aluminium cowl construction, with fan incorporated, for longevity of operation
• Supported by a two year warranty• For technical specification refer page 72
• High quality aluminium cowl construction, with fan incorporated, for longevity of operation
• Includes Dektite for metal based roofs, an optional lead dektite is available for concrete tile roofs (DCT0190) at an additional cost
• Supported by a two year warranty• For technical specification refer page 72
* NOTE: All fan flow rates quoted are motor performance in free air.
Connection:1. Electrical connection can be made inside or outside the roof space.
• High quality aluminium cowl construction, with fan incorporated, for longevity of operation
• Includes Dektite for metal based roofs, an optional lead dektite is available for concrete tile roofs (DCT0190) at an additional cost
• Supported by a two year warranty• For technical specification refer page 72
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 27
• A compact extractor fan combined with an integral halogen light
• Designed for installation in galleys, showers and toilets, ideal for marine and other leisure applications
• Long life computer motor which will run continuously, only 2.8 watts
• Supported by a two year warranty• For technical specification refer
page 73
• External cowl suitable for use in marine and non-marine applications
CLASSIC DC Extract-a-lite Models
Specialised Ceiling Mounted Fans
12/24 volts, DC suitable for marine/recreational vehicle use.Metric Size Model No. Switching
MethodColour Performance Order Code
100mm BSL112W Standard White 18l/s, 64m³/hr FAN0625
100mm BSL112G Standard Gold 18l/s, 64m³/hr FAN0690
100mm BSL112C Standard Chrome 18l/s, 64m³/hr FAN0691
100mm BSL124W Standard White 18l/s, 64m³/hr FAN0626
100mm BSL124G Standard Gold 18l/s, 64m³/hr FAN0686
100mm BSL124C Standard Chrome 18l/s, 64m³/hr FAN0685
Metric Size Description Order Code
100mm Extract-a-lite cowl DCT1097
ACCESSORIES - EXTRACT-A-LITE COWL
Switching Options:1. Standard Model - operates from remote switch (not supplied)NOTE: All fan flow rates quoted are free air delivery.
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au28
Specialised Fans
Product codes1. Product with the “order code” showing are generally ex-stock - other products are available to orderNOTE: All fan flow rates quoted are free air delivery.
CLASSIC Hand Dryer Models
• High quality, warm air hand drier that is suitable for use within office and commercial organisations, such as clinics and catering establishments
• It is not recommended for use in public areas prone to vandalism• Supported by a two year warranty• For technical specification refer page 67
Metric Size(mm)
Model No. Switching Method
Performance Order Code
275x225x160 MAN M-88A Auto 56l/s, 200m³/hr FAN2902
• This model is suitable for use in public areas such as lavatories, factories, schools, railways and motorway service stations and are designed for heavy usage and unsupervised areas
• Supported by a two year warranty• For technical specification refer page 67
Metric Size(mm)
Model No. Switching Method
Performance Order Code
248x284x202 MAN/E-88A Auto 130l/s, 470 m³/hr FAN2903
Frame Fan ModelMetric Size Model No. Switching
MethodPerformance Order Code
125mm Frame Fan Standard 38l/s, 138m³/hr FAN0397
150mm Frame Fan Standard 89l/s, 320m³/hr FAN1043
Metric Size Description Order Code
125mm Finger Guard for FAN0397 - Metal FAN0412
125mm Finger Guard for FAN0397 - Plastic FAN1044
125mm Filter Guard for FAN0397 FAN0413
150mm Finger Guard for FAN1043 FAN0841
ACCESSORIES
• This frame fan is designed for use in computer rooms or applications where the introduction of cool air is required for small enclosed spaces
• The ball bearing motor prolongs the life of the motor• Supported by a two year warranty• For technical specification refer page 73
Frame Fan 125mm
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 29
Fan Accessories
Fan Timer
Transformers
Model No. Description Order Code
Time Air 7 Minute Fixed Timer (suits fans 20W-200W) FAN0372
• A fixed fan timer that will automatically switch the appliance off after 7 minutes
Model No. Description Order Code
ACTO TE0060 Electronic Transformer 12VAC 50kHz FAN2101
• This transformer must only be used with 12v lighting installations• Supports lamp wattages from 20W - 60W• Overload & short circuit protection with self resetting. • Over temperature cut off • Dimmable with trailing and leading edge dimmers
Humidistat Controller
Model No. Description Order Code
1360 Humidistat Controller FAN0963
• Designed to operate the fan when the relative humidity reaches a pre-set level.
• Fits a double pattress• This unit is adjustable between 20 - 90% RH
Model No. Description Order Code
TBA SELV Isolating Transformer 12VAC FAN2402
• SELV isolating transformer is required for all low voltage fan installations• Can be used with low voltage 12v lighting• Supports lamp wattages from 20W - 50W • An Iron Core Transformer• Thermally stable and shatter-proof plastic casings• Overload & short circuit protection with self resetting • Over temperature cut off• Dimmable with trailing and leading edge dimmers
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au30
ULTECON Thermostats Model No. Description Order Code
TA01 Analogue Thermostat FAN0153
TD01 Digital Thermostat FAN0981
TD02 Digital 2 Speed Thermostat FAN0982
TD03 Digital 3 Speed Thermostat FAN0983
• High quality, easy to use thermostats• Dual output switching for both cooling and heating situations• Electronic temperature sensor• Included in Heat Trans systems
• A range of speed controllers with variable or 2 speed and reversible options• Models 1348-1350: Electrical load must be between 20 and 200 watts• FAN0154 - Single pattress mounting block for FAN0155/0156/0157 *Not suitable for Manual Pull Cord Models
Speed ControllersModel No. Description Switching Method Order Code
1348 For XF/XP/WF230/300 Fans*
2 Spd + Reverse FAN0155
1349 For XF/XP/WF230/300 Fans*
Adjust + Reverse FAN0156
1350 For any XF/XP/WF 230/300 Fans
Adjustable FAN0157
PDL625F General Purpose up to 500W On-Off + Adjust FAN2104
Fan Accessories
Model No. Description Input Current
Output Power
Order Code
SPC05 Ultecon 5 Speed Fan Controller 1A 100W FAN1096
ULTECON Speed Controller
• 5 speed fan selection - manual or external control • Enclosure can be wall mounted or free standing• On/Off switch• Choice of fixed wired or lead and plug
Fan Mounting Brackets
• These adjustable fan mounting brackets, designed for use with the centrifugal fans
• Supplied in pairs
Metric Size Description Order Code
100-200mm Fan Mounting Bracket for 100-200mm FAN0015
250-315mm Fan Mounting Bracket for 250-315mm FAN0016
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 31
• Fully complies to AS4254 & AS4508 & AS1530 Pt3• DUCT CORE : Aluminium foil laminated onto polyester film, permanently bonded onto a
corrosion resistant coated, spring steel wire helix• DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised• DUCT INSULATION: AS4508 Polyester R0.6 nominal 250grams per mtr/sq 40mm thick• TEMPERATURE RANGE: Maximum: +150˚C : Minimum: -30˚C• COLOUR: Silver with black sleeve• See Friction Loss Graph on page 78• Ducting Installation Tips see pages 74 - 77
Ducting
Nude
Insulated
NUDE INSULATEDDiameter
(mm)Length
(m) Order Code Order Code
100136
DCT0357DCT0328DCT0409
125136
DCT0358DCT0329DCT0410
150136
DCT0359DCT0330DCT0411
DCT0088DCT0399
20036
DCT0331DCT0412
DCT0089DCT0343
25036
DCT0332DCT0413
DCT0400
30036
DCT0380DCT0414
DCT0401
35036
DCT0415DCT0416
DCT0403
40036
DCT0417DCT0418
DCT0405
NOTE: All 1 metre lengths are packed in bags with header cards, 3 metre nude duct is supplied boxed up to 250mm and all other items are supplied in colour coded bags.No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure.
ALUDUCT™ Flexible Ducting
INSULATED R0.6
Diameter (mm)
Length (m) Order Code
15036
DCT0633DCT0634
20036
DCT0635DCT0636
UNILOK FR1 Acoustic Ducting is a flexible duct manufactured “tough” & “whisper quiet” for consumer & installer peace of mind. Unlike other types of flexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and correct diameter, even in the tightest bends. Due to its steel rib, it is not prone to glue failure or fatigue (sagging or ovalisation) from vibration with age like plastic ribbed or non ribbed glued duct.
UNILOK™ FR1 Acoustic Ducting
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au32
Ducting
• Fully complies to AS1530 Building code • DUCT CORE: Spiral wire reinforced PVC film construction.• Non collapsing/Non rotting• Vapour-proof• Fire retardant • TEMPERATURE RANGE: Maximum: +50˚C : Minimum:6˚C• COLOUR: White PVC• Ducting Installation Tips see page 74 - 77
Diameter (mm)
Length (m) Pack Order Code
100 13
Header CardedBoxed
DCT0936DCT0336
125 14
Header CardedBoxed
DCT0937DCT0337
150 15
Header CardedBoxed
DCT0938DCT0338
Diameter (mm)
Length (m) Pack Order Code
100 1.53
BoxedLoose
DCT0333DCT0114
125 1.53
BoxedLoose
DCT0334DCT0115
150 1.53
BoxedLoose
DCT0335DCT0116
200 3 Loose DCT0117
250 3 Loose DCT0118
300 3 Loose DCT0119
350 3 Loose DCT0120
400 3 Loose DCT0477
• Fully complies to the BCA• DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam• Holds shape, self supporting• TEMPERATURE RANGE: Maximum: +250°C, Minimum: -30°C• COLOUR: Silver• Ducting Installation Tips see page 74 - 77
P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry. It doesn’t rot, is non collapsing, is fire resistant, has an operating temperature of +6 deg to +50 deg and is available in a range of sizes from 100mm to 150mm.
SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, flexible but strong corrugated aluminium duct. It is spiral wound with a unique interlocked and knotted continuous seam. It is self supporting over longer lengths and generally only needs fittings or mechanics at each end for support.
PVC Flexible Ducting
SEMIDUCT Semi Rigid Ducting
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 33
Ducting
Low profile ducting enables it to be concealed when installed along the top of wall units. It can also be fitted in ceiling voids and cavity walls, providing versatility whilst remaining unobtrusive. All Manrose system parts and channels are made from flame-retardant material.
Four Low Profile System Sizes110mm x 54mm: Suitable for applications requiring low extraction rates, such as ventilation of domestic bathrooms and toilets. With a 5940mm² cross-section it provides efficient ducting for short, straight runs connecting to a 100mm round spigot. 204mm x 60mm: Suitable for ducting of kitchen cooker hoods with 100, 125 or 150mm round exhaust spigots. The flat channel cross section of 12240mm² increases efficiency. High Performance 220mm x 90mm: Suitable for applications requiring high performance extraction or supply. The flat channel cross section of 19800mm² makes it highly efficient and higher extraction rates are achieved.Flat Ducting 300mm x 25mm: Suitable for applications where space is very limited
Dimension(mm)
Equivalent Size (mm) Length (m) Order Code
110 x 54 100 1.5 DCT0013
204 x 60 125 1.5 DCT0519
220 x 90 150 1.5 DCT1443
300 x 25 100 1.5 DCT1460
Diameter(mm) Length (m) Finish Order Code
100 0.9 Galvanised DCT0151
100 0.9 White DCT0145
125 0.9 Galvanised DCT0152
125 0.9 White DCT0146
125 1.2 Galvanised DCT0953
150 0.9 Galvanised DCT0153
150 0.9 White DCT0147
150 1.2 Galvanised DCT0954
Diameter (mm) Length (m) Finish Order Code
100 0.9 PVC DCT1424
125 0.9 PVC DCT1425
150 0.9 PVC DCT1426
Solid Tube - Rigid Steel
Solid Tube - White Plastic
Solid Tube
Low Profile Ducting - Flat Channel
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au34
Duct Fittings
Rectangle Dimension (mm) Order Code
110 x 54 DCT0014
204 x 60 DCT0520
220 x 90 DCT1442
300 x 25 DCT1459
Low Profile Connectors
Rectangle Dimension (mm) Order Code
110 x 54 DCT1479
204 x 60 DCT1114
Horizontal T-Piece Connectors
Adaptors (Rectangular : Round)
Short Adaptors (Rectangular : Round)
(Designed to fit 204 x 60mm flat channel or airbrick)
Flat Channel Reducer
Rectangle Dimension (mm) Round (mm) Order Code
110 x 54 100 DCT1482
204 x 60 125 DCT0526
220 x 90 150 DCT1446
300 x 25 100 DCT1461
Rectangle Dimension (mm) Round Diameter (mm) Order Code
100 x 54 100 DCT0127 (f)
110 x 54 100 DCT0131 (m)
Rectangle Dimension (mm) Order Code
110 x 54 : 204 x 60 DCT0136
204 x 60 : 220 x 90 DCT1452
204 x 60 : 300 x 25 DCT1456
(m) = Male(f) = Female
Round Adaptor (Round : Round)
Round Diameter (mm) Order Code
125 DCT0448
Low Profile Duct Fittings
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 35
Rectangle Dimension (mm) Order Code Order Code Order Code
110 x 54 DCT0124 (m)
110 x 54 DCT0015 (f)
204 x 60 DCT0521 DCT0522 DCT0523
220 x 90 DCT1444 DCT1440* DCT1441*
300 x 25 DCT2095 DCT2096
HoRIzoNTAL VERTIcALRectangle Dimension (mm) Order Code Order Code
110 x 54 DCT0125 DCT0126
204 x 60 DCT0524 DCT0525
220 x 90 DCT1448 DCT1447
300 x 25 DCT2097 DCT2099
HoRIzoNTAL VERTIcALRectangle Dimension (mm) Order Code Order Code
300 x 25 DCT2098 DCT1455
*Rotating offset spigot(m) = Male (f) = Female
100mm 125mm 150mm
Rectangle Dimension (mm) Order Code
204 x 60 DCT1480
90º Bends
45º Bends
Elbow Bends (Rectangular : Round)
Adjustable Horizontal Bend
Elbow Bend
Horizontal
Vertical45º Bend
Adjustable Horizontal Bend
Horizontal
Vertical90º Bend
Duct Fittings
*2 clips are required to secure ducting
A B
Flat Channel Clips
Rectangle Dimension (mm) Order Code
110 x 54 (A) DCT0134
204 x 60 (A) DCT0527
220 x 90 (B) DCT1445*
300 x 25 (B) DCT1458*
Low Profile Duct Fittings
• Designed to fit directly into the round solid tube• For systems ducted straight through an external wall
Metric Size (mm) Order Code
100 DCT2206
Standard external grille
Standard
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au36
Duct Fittings
Round Diameter(mm)
Square Dimension (LxW mm) Order Code
104 155 x 155 DCT0148
130 170 x 170 DCT0149
160 200 x 200 DCT0150
Wall/Ceiling Plate - Round
Internal Dimension(LxW mm)
External Dimension (LxW mm) Order Code
110 x 54 155 x 155 DCT0016
204 x 60 264 x 118 DCT0528
Wall/Ceiling Plate - Rectangle
Rectangle Dimension (mm) Order Code
220 x 90 : 232 x 138 DCT1451
Rectangle Dimension (mm) Order Code
232 x 138 DCT1450
The following Reducer or Connector is required to connect the Airbrick insert to the Duct: 110 x 54mm: requires Reducer order code: DCT0136
Rectangle Dimension (mm) Airbrick Direction Order Code
204 x 60 Horizontal DCT0137
204 x 60 Vertical DCT1414
Double Airbrick Adaptor
Double Airbrick
Double Airbrick Reducer
Airbrick Insert (204 x 60mm)
(W)
(L)
Rectangle Dimension (mm) Order Code
235 x 140 DCT1453
Low Profile Duct Fittings
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 37
Branch Take-Offs (BTO)
Duct Fittings
METALPoLYMetric Size (mm) Order Code Order Code Order Code
125-100 DCT2067
150-100 DCT2122
150-125 DCT2066
200-125 DCT0084
200-150 DCT0486
NOTE: Products with the “order code” showing are generally ex. stock lines - other products are available to order
PVc
PVC Plastic
Reducers
• *DCT0159isaPVCductjoiner
METALLoNG
METAL SHoRT
METAL PLATE SPIGoTS
Metric Size (mm) Order Code order code order code order code
100 DCT0159*
125 DCT0037
150 DCT0723 DCT0059 DCT0935
200 DCT0724 DCT0071 DCT0939
250 DCT0725 DCT0339 DCT0940
PoLY
Metal Long Metal Short
Metal Plate Spigots
Duct Joiners/Spigots
• ManufacturedfromHDPE,U.V.stabilised• Heavyduty,robust,smoothinternallines• Nosharpedges,Positivelockducttabs• InsulationmeetsAS1530part3• InsulationmaterialLDPE,thickness5mm
PoLY INSULATEDMetric Size (mm) Order Code Order Code
100-100-100 DCT1439
125-125-125 DCT1501
150-150-150 DCT0091 DCT0875
200-150-150 DCT0719 DCT0876
200-200-150 DCT0460 DCT0877
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au38
EGGcRATE GRILLES
Metric Size (mm) Colour Order Code
100 White DCT0375
125 White DCT0472
150 White DCT0473
• Improved ‘air-flow’ characteristics• Removable insert for easy cleaning
Metric Size (mm) Colour Order Code
100 White DCT0025
100 Grey DCT0024
100 Terracotta DCT0026
125 White DCT0041
125 Grey DCT0039
125 Terracotta DCT0040
150 White DCT0063
150 Grey DCT0062
150 Terracotta DCT0064
200 White DCT0340
230/250 White DCT0073
300 White DCT1979
FIxED LoUVRE GRILLES
GRAVITY GRILLESMetric Size (mm) Colour Order Code
100 White DCT0029100 Grey DCT0028100 Terracotta DCT0027
125 White DCT0044
125 Grey DCT0042
125 Terracotta DCT0043
150 White DCT0066
150 Grey DCT0061
150 Terracotta DCT0065
230/250 White DCT2204
300 White DCT1981
• Standard grille with some weather protection• Removable insert for easy cleaning
• Prevents back draughts & weather penetration
Metric Size (mm) Colour Order Code
100 Stainless Steel DCT2145
125 Stainless Steel DCT2146
150 Stainless Steel DCT2147
DESIGNER SERIES GRAVITY GRILLES
• High quality designer stainless steel finish
• Technical data see page 79
• Technical data see page 81
Fixed Wall Ceiling Grilles
Gravity Wall Grilles
Grilles & Diffusers
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 39
• Low Profile eggcrate design improves airflow in extraction applications• Twist lock fascia for easy cleaning• Gib fixing clips included• Longer spigot for easy duct connection• Satin Silver & Chrome fascias available see page 12 or 15• Technical data see page 79
ACCESSORIES
Accessories
Metric Size (mm) Description Colour Order Code
100 Circular White DCT1089
100 Square White DCT2223
125 Circular White DCT1090
125 Square White DCT2224
150 Circular White DCT1067
150 Square White DCT2225
Metric Size (mm) Description Colour Order Code
125 Circular Fascia White FAN0748
125 Square Fascia White FAN0747
150 Circular Fascia White FAN0750
150 Square Fascia White FAN0749
125 Spigot Black DCT1074
150 Spigot Black FAN0656
Low Profile Wall/Ceiling Grille
Grilles & Diffusers
• High quality designer finish available in either white or brushed aluminium silver• Designed for bathroom extraction that blends into any decor• Technical data see page 79
Metric Size (mm) Colour Order Code
150 White DCT2236
150 Silver DCT2237
DESIGNER SERIES SQUARE WALL/cEILING GRILLE
Square Wall/Ceiling Grille
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au40
Grilles & Diffusers
• Manufactured from A.B.S plastic • Designed for either supply or extract ventilation• Fixing flange included, screws required• Adjustable screw in centre cone• Technical data see page 80
Metric Size (mm) Colour Order Code
100 White DCT0020
125 White DCT0174
150 White DCT0058
200 White DCT0068
‘ECO’ Ceiling Diffuser
• Concentric circular grille designed for extraction• Technical data see page 79
Metric Size (mm) Colour Order Code
100 White DCT2185
125 White DCT2186
150 White DCT2187
Circular Wall/Ceiling Grille
FIxED LoUVRE VENTPlate Size (mm) colour order code
245 x 80 White DCT2194
245 x 80 Chrome DCT2195
245 x 160 White DCT2196
245 x 160 Chrome DCT2197
245 x 245 White DCT2198
245 x 245 Chrome DCT2199
ADjUSTAbLE VENTPlate Size (mm) colour order code
245 x 80 White DCT2188
245 x 80 Chrome DCT2189
245 x 160 White DCT2190
245 x 160 Chrome DCT2191
245 x 245 White DCT2192
245 x 245 Chrome DCT2193
• Manufactured from PVC in either white or chrome finish• Designed for use when make-up air is required• Fixed Louvre provides maximum airflow• Adjustable Vent can be fully closed off when not required
Wall/Ceiling Plate Vents
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 41
Grilles & Diffusers
• Manufactured from ABS plastic • Designed for either supply or extract ventilation• When used to supply, the air will be pushed down into the room• These diffusers are designed for use in heat transfer systems
(refer to page 46-49)• Spring loaded fixing clips• Resistant to scratching and fading• Positive lock duct tabs• Adjustable screw in centre cone to ensure a balanced airflow• Technical data see page 80
Metric Size (mm) Colour Order Code
150 White DCT1472
200 White DCT1473
250 White DCT1474
300 White DCT1475
• High quality designer finish• Designed to supply air into your home, by pushing the air
along the ceiling and down the walls. Suitable for use in home ventilation systems
• Technical data see page 80
Metric Size (mm) Colour Order Code
150 White DCT2208
• High quality designer stainless steel finish• Designed for internal extraction where a quality finish is required• Technical data see page 80
Metric Size (mm) Colour Order Code
100 Stainless DCT2139
125 Stainless DCT2140
150 Stainless DCT2141
DESIGNER SERIES cEILING DIFFUSERS
Stainless Steel Ceiling Diffuser
Low Profile Flat Ceiling Diffuser
Cone Ceiling Diffuser
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au42
• High quality designer stainless steel finish• Designed for use where adverse weather conditions are experienced• Manufactured from a 304 grade stainless steel• Technical data see page 81
Metric Size (mm) Colour Order Code
100 Stainless Steel DCT2151
125 Stainless Steel DCT2152
150 Stainless Steel DCT2153
Metric Size (mm) Colour Order Code
100 Stainless Steel DCT2157
125 Stainless Steel DCT2158
150 Stainless Steel DCT2159
• Used where adverse weather conditions are experienced• Technical data see page 81
Metric Size (mm) Colour Order Code
100 White DCT0018
100 Brown DCT0019
125 White DCT1030
150 White DCT1031
WEATHERPRooF coWL
DESIGNER SERIES WEATHERPRooF coWL
DESIGNER SERIES WEATHERPRooF DoME coWL
• High quality stainless steel dome cowl for a modern stylish look• Designed for exhaust and supply ventilation• Generally mounted on an external wall, however they can be mounted internally• Manufactured from a 304 grade stainless steel• Insect mesh included• Technical data see page 81
Weatherproof Cowl
Weatherproof Dome Cowl
Grilles & Diffusers
Model No. Description order code
Door Vent Internal Door Ventilator Grille FAN0159
• This door grille allows make-up air into the room• Dimensions: 455mm(h) x 90mm(w) to fit door with depth of 33mm
Door Grille
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 43
Thru Roof Mounted Cowls/Kits
• General Purpose Cowl - Low profile• Low back pressure• Heavy Duty Cowl - Aluminium construction
- Added exhaust aperture area and deep vent coverage - Recommended where high winds in exposed locations may drive rain into the vent - Also recommended for use in high airflow air intake systems to prevent rain being sucked into the system
• Technical data see page 72
Metric Size (mm) Description Order Code
150 General Purpose Cowl DCT0708
150 Heavy Duty Cowl DCT0709
Roof Cowls
Metric Size (mm) Description Order Code
150 General Purpose Kit DCT0172
150 Heavy Duty Cowl Kit DCT0710
150 General Purpose Lead Flashing Kit DCT1095
• General purpose cowl included• 0.5m HDPE Tube included• Dektite included (for metal based roofs)• All fittings supplied• Optional lead Dektite available (extra cost - refer to Roof Flashings page 39)• NB: Lead Dektite (DCT0190) required for concrete tile roofs
• Reducers fit to the bottom of HDPE tube to adapt to smaller duct diameters where required
Plastic Reducers for HDPE Thru-Roof Tube (for thru-roof kits)
Metric Size (mm) Description Order Code
150:125 150:125 reducer DCT2066
150:100 150:100 reducer DCT2122
Metric Size (mm) Description Order Code
100 Angled Roof Kit DCT2205
• General purpose through roof kit for smaller application• To be mounted on tile roofs• Complete kit - Cowl, 0.5m of tube & weathering slate included
Roof Cowl Kits with Dektite & HDPE Tube
Angled Roof Cowl Kit
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au44
Rangehood Ducting Kits
Metric Size (mm) Description Order Code
150 Thru-Soffit Kit DCT2323
Thru Soffit Kits
Thru Roof KitsMetric Size (mm) Description Order Code
150 Thru-Roof Kit (with Dektite Flashing) DCT2324
• 150mm x 3m Aluminium Duct• 1 x 150/125mm Round Reducer• 1 x 150mm Duct Joiner
• 1 x 150mm Eggcrate Grille• 3m Semi Rigid Duct• All fittings and fixings
Metric Size (mm) Description Order Code
150 Thru-Wall Kit DCT2592
Thru Wall Kits
• 1 x 150mm Weatherproof Cowl • 150mm x 1.5m Rigid Duct• All fittings and fixings
• 150mm x 3m Aluminium Duct• 1 x 150/125mm Round Reducer• 1 x 150mm Duct Joiner
Metric Size (mm) Description Order Code
150 Thru-Roof Kit (with Lead Flashing) DCT2325
• 150mm x 3m Semi Rigid Duct• 150mm Roof Cowl• 1 x 600m Metal Strap• 1 x 150/125mm Reducer
• 1 x 150mm Duct Joiner • 2 x 150mm x 0.9m Galvanised Tube• 1 x 150mm Dektite Flashing• All fittings and fixings
• 150mm x 3m Semi Rigid Duct• 150mm Roof Cowl• 1 x 600m Metal Strap• 1 x 150/125mm Reducer
• 1 x 150mm Duct Joiner• 2 x 150mm x 0.9m Galvanised Tube• 1 x 150mm Lead Flashing• All fittings and fixings
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 45
Duct Accessories
Insect Mesh
Metric Size (mm) Description order code
100 For 100mm Grilles DCT0371
125 For 125mm Grilles DCT0208
150 For 150mm Grilles DCT0207
250 For 200mm & 250mm Grilles DCT0373
150 Bird Mesh DCT2263
Duct Straps and Duct Tape
*AS4254 Duct tape DCT1132
- Temperature range -37°C - 127°C AS4254 Duct Tape
Ducting Straps & Duct Tape
Metric Size (mm) Description order code
100mm Ducting Strap FAN0274
125mm Ducting Strap FAN0281
150mm Ducting Strap FAN0282
12mm x 3m Hanging Strap DCT2299
25mm x 50m Hanging Strap DCT0808
48mm x 5m Duct Tape DCT017348mm x 30m Duct Tape DCT080748mm x 60m Duct Tape - *AS4254 DCT1132
Description Order Code
Dektite Roof Flashing - fits 110-160mm DCT0180Tiledek Roof Flashing - For use on concrete
tile, clay tile and slate roofing DCT0190
0.5m HDPE Tube 150mm DCT0183
Stitching Screws (for roof fastening) FAN0400
Roof Flashings
Metric Size (mm) order code order code
100 FAN0213
125 DCT0036
150 DCT0511
200 DCT2092
PVc METAL
In-Line Backdraught Shutters
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au46
Heat Transfer
Heat Trans is the professional brand in heat transfer systems. Heat Trans is the brand of choice for electrical contractors and has been leading the market for over 15 years. Heat Trans is at the forefront of product development and innovation and are the only heat transfer systems using acoustic insulated ducting and digital controllers.
Ultimate ControlFor the ultimate in control, Heat Trans systems include high quality Ultecon digital controllers which automatically control when the system operates to maintain your preset comfort level in your lounge. They provide accurate readings for temperature settings and speed control selection (where applicable).
Whisper QuietHeat Trans systems use unique acoustic insulated ducting to provide a ‘whisper quiet’ system within your home. This specially designed ducting is only available in Heat Trans systems and retains heat when distributing warm air around your home.
Easily AdjustableThe outlets within your home are easily adjustable to allow balancing of the airflow into each room. Simply twist the centre section of the diffuser to allow more or less air into each room. Or if your diffuser is located in a guest bedroom you can simply close that diffuser completely when the room is not in use.
Energy EfficientYou can run a Heat Trans system for less than the cost of a light bulb! The one room system uses an amazingly low 46W, which is about half the consumption of an averaged sized light bulb. The two-room system uses up to 80W and the three-room system uses up to 110W. These high quality fans have been specifically selected to ensure correct airflow and pressure levels are achieved.
Optional Summer FeatureTo enable your system to benefit your family during hot the summer months, a ‘Summer-Vent’ extension kit can be added to allow fresh, filtered air to circulate through your Heat Trans outlets. This feature introduces fresh air in the summer months, however if you are looking a for a year round home ventilation solution.
Why Choose Heat Trans:
Transfer heat from one room to other rooms in your home
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 47
Heat Transfer
HEAT TRANS utilises excess heat by transferring it from one room to multiple rooms within the home
Ultimate ControlThe Ultecon high quality digital thermostat controllers accurately measure and display the temperature of your lounge as well as allowing you to preset your preferred room temperature.
When your lounge temperature exceeds your preferred room temperature the system will automatically start to transfer the excess heat to other rooms in your home.
Once set you can sit back and relax and let the controller do all the work. The 2 and 3 room kits also offer fan speed control, which allows you to set your preferred fan speed giving you ultimate control over the volume of heated air being transferred.
ONE ROOM TWO/ THREE ROOM
STEP 1 STEP 2 STEP 3
Excess heat from your heat source will rise to ceiling level where it is trapped by ceiling insulation. This excess heat can reach temperatures of 30-35°C.
This excess heat can be effectively transferred to other rooms using a high quality fan and acoustic insulated ducting.
Natural re-circulation occurs, resulting in a continual movement of warm air through the home, helping to reduce mould and mildew.
How Heat Trans Works:
All Heat Trans kits can be extended.
1 ROOM KITS can be extended to a maximum length of 12 metres (6 metres supplied in kit).
2 ROOM KITS can be extended to a maximum length of 21 metres (12 metres supplied in kit).
3 ROOM KITS can be extended to a maximum length of 24 metres (15 metres supplied in kit).
Acoustic Insulated Ducting is available in 3 and 6 metres lengths and will require a duct joiner:
150mm x 3 metre acoustic insulated duct - Order Code: DCT0633 150mm x 6 metre acoustic insulated duct - Order Code: DCT0634 200mm x 3 metre acoustic insulated duct - Order Code: DCT0635 200mm x 6 metre acoustic insulated duct - Order Code: DCT0636 150mm Duct Joiner - Order Code: DCT0723 200mm Duct Joiner - Order Code: DCT0724
Ducting Considerations
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au48
Heat Transfer Kits
Outlet Size Description Fan Speeds Order Code
150mm Heat Trans One Room Kit 1 FAN0325
Kit includes:1 x Ultecon Digital Thermostat Controller 1 x 150mm High Performance Axial Flow Fan 2 x 3 Metres - 150mm Acoustic Insulated Ducting 1 x Circular Inlet Grille 1 x Adjustable Circular Design Outlet Diffuser All Fittings and Fixings Included
Outlet Size Description Fan Speeds Order Code
150mm Heat Trans Three Room Kit 3 FAN0338
Three Room Kit
Kit includes: 1 x Ultecon Digital Thermostat/ Fan Speed Controller 1 x 200mm Multi-Speed High Performance Fan 3 x 3 Metres - 150mm Acoustic Insulated Ducting 2 x 3 Metres - 200mm Acoustic Insulated Ducting 1 x Double Branch Take-Off (Three Way Splitter) 1 x Circular Inlet Grille 3 x Adjustable Circular Design Outlet Diffusers All Fittings and Fixings Included
Outlet Size Description Fan Speeds Order Code
150mm Heat Trans Two Room Kit 2 FAN0337
Kit includes:1 x Ultecon Digital Thermostat/ Fan Speed Controller1 x 150mm Multi-Speed High Performance Fan4 x 3 Metres - 150mm Acoustic Insulated Ducting1 x Branch Take-Off (Splitter)1 x Circular Inlet Grille 2 x Adjustable Circular Design Outlet DiffusersAll Fittings and Fixings Included
Two Room Kit
One Room Kit
Year Warranty
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 49
Heat Transfer Kits
Introduce fresher cooler air into your home in summer with the Summer-Vent Extension Kit, to enable year round use of your system.With the inlet grille installed under your soffit, fresher cooler air is filtered using a high efficiency F7 filter and is distributed throughout your home via your Heat Trans outlets. The system is controlled via a standard wall switch which operates the motorized damper to start drawing air from outside.
Designed to extend your standard Heat Trans system so you can distribute warm air to four bedrooms within your home. The Pro-Series Outlet extension kit includes 3 metres of duct, a Y branch connection and a Heat Trans outlet to enable your excess heat to be transferred to an additional room within your home. Please note: by adding additional outlets you are simply dividing the available warm air amongst more rooms.
Note: When the summer feature is working the lounge/warmed room inlet is switched off via the damper and will not receive the cooled air directly from outside, however due to air pressure a natural re-circulation occurs throughout the home.
For additional ducting please see page 31
Outlet Size Description Order Code
150mm Pro-Series One Outlet Extension Kit DCT2101
Outlet Size Description Order Code
150mm Summer Vent Extension Kit DCT1481
Summer Vent Extension Kit Includes
1 x Y Branch (Splitter)1 x 3 Metres - 150mm Acoustic Insulated Ducting1 x Adjustable Circular Design Outlet DiffuserAll Fittings and Fixings Included
Kit includes:1 x Branch Take Off (Splitter) including Motorised Dampers1 x 200mm F7 Filter Box1 x 3 Metres - 200mm Unilok Ducting1 x 200mm Fixed Grille2 x 200/150 reducers (only required if adding to a one or two room Heat Trans system)Electrical: single pole, double throw 230 volt rated wall switch required - not included.
Pro-Series One Outlet Extension Kit
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au50
Technical Contents
CLASSIC Hyper150 Models 65
CLASSIC ID Models 66
CLASSIC CFD Models 67
In-Line Fans 65 - 67
CLASSIC DC Extract-a-lite Models 73
Frame Fan AC Models 73
Specialised Fans 73
Window Fans 56
PRO SERIES XPLP Low Profile Models 54
CLASSIC XP Models 55
Wall/Ceiling Fans 51 - 53
PRO SERIES XFLP Low Profile Models 51
CLASSIC XF Models 52
DESIGNER Ceiling Fan Models 53
CLASSIC Centrifugal Models 53
Thru Wall Fan Kits 54 - 55
PRO SERIES Mixflo™ Shower Fan Models 60
PRO SERIES SFLP Shower Fan Models 61
CLASSIC SF Shower Fans Models 62
PRO SERIES ELLP Extract-a-lite Models 63
CLASSIC EL Extract-a-lite Models 64
In-Line Fan Kits 60 - 64
PRO SERIES Heat ’n Vent Models 59
CLASSIC Heat ’n Vent 2 Model 59
CLASSIC 2 Heat ’n Light Model 59
Heat/Fan/Light Units 59
Commercial Fans 57 - 58
CLASSIC XF 230 & 300mm Models 57
Commercial WF/Com XP 230 & 300mm Models 58
Externally Mounted Fans 71
Ducting Installation Guidelines 74 - 77
Flexible Ducting Friction Loss Graph 78
FANS
Stainless Steel Ceiling Diffuser 79
Cone Ceiling Diffuser 79
‘ECO’ Ceiling Diffuser 79
Low Profile Flat Ceiling Diffuser 79
Square Wall/Ceiling Grille 80
Circular Wall/Ceiling Grille 80
Low Profile Wall/Ceiling Grille 80
Fixed Wall/Ceiling Grilles 80
Gravity Wall Grilles 81
Weatherproof Cowl 81
Weatherproof Dome Cowl 81
Grilles & Diffusers 79 - 81
Ducting 74 - 78
Index 82 - 84
DUCT
Thru Roof Fans 72
Hand Dryer Models 67
High Performance Centrifugal Models 68
High Performance Centrifugal 3 Speed Models 69
WhisperVent Low Profile Models 70
In-Line Fans cont. 68 - 70
Notes 85 - 87
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 51
Models A B C D
XFLP125S 161 122 10 118
XFLP125C 165 122 10 118
XFLP150S 191 122 10 150
XFLP150C 198 122 10 150
Models Circular Cut-Out Size
XFLP125S 140mm - with gib fixing clips used
XFLP125C 140mm - with gib fixing clips used
XFLP150S 173mm - with gib fixing clips used
XFLP150C 173mm - with gib fixing clips used
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models XFLP125 XFLP150
Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V)
Fan Performance 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 25W
Maximum Pressure 35Pa 60Pa
Fan Speed 2000 rpm 2400 rpm
Sound Level 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC
IP Rating IPX4 IPX4
WALL/CEILING FANS - XFLP Low Profile Models
D
Dimensions - XFLP
A BC
A
Performance - XFLP125 Performance - XFLP150
Technical Data
A
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au52
Models A B C D E
XF100 155 98 74 27 155
XF125 168 118 74 27 168
XF150 200 148 74 27 200
XF150PIR 200 148 90 55 200
XF150A/AP 200 148 90 55 200
Models Circular Cut-Out Size
XF100 112mm
XF125 135mm
XF150 160mm
GENERAL INFORMATION
DIMENSION INFORMATION
WALL/CEILING FANS - XF Models
TECHNICAL SPECIFICATION
Models XF100 XF125 XF150
Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V) 220 - 240V (LV models 12V)
Fan Performance 23/s, 85m³/hr 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 20W 25W
Maximum Pressure 20Pa 35Pa 60Pa
Fan Speed 2400 rpm 2000 rpm 2400 rpm
Sound Level 41 dB(A) 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4
Performance - XF100 Performance - XF125 Performance - XF150
A
B
CD
E
Dimensions - XF
Technical Data
Please note: Fan cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 53
Models A B C D E F G H
WhisperVent 240 290 172 98 - - - -Multi-Vent FFCF234 91 96 141 250 15 155 210 -
Multi-Vent SMCF234 312 250 15 119.5 22.5 63 249 -
CF200 65 65 185 260 45 98 90 135
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models DESIGNER Multi-Vent CF200
1 Speed 2 Speed 3 Speed
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Performance 63l/s, 225m³/hr 28l/s, 100m³/hr 45l/s, 162m³/hr 65l/s, 234m³/hr 31l/s, 110m³/hr
Fan Wattage 30W 40W 80W 110W 45W
Maximum Pressure 105Pa 140Pa 165Pa 180Pa 120Pa
Fan Speed 2500 rpm 950 rpm 1500 rpm 1850 rpm 1400 rpm
Sound Level 38 dB(A) 37 dB(A) 51 dB(A) 56 dB(A) 45 dB(A)
Max. Operating Temp 40oC 50oC 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4 IPX4 IPX4
WALL/CEILING FANS - DESIGNER/CF Models
Performance - CF200
NOTE 1,2,3 refer to speed settings controlled by internal switch (not consumer adjustable)
Performance - Multi-Vent
0
120
80
40
0
0 15 30 45 60 75VOLUME L/SEC
STA
TIC
PR
ES
SU
RE
Pa
10
20
54 162 216 270
200
160
STA
TIC
PR
ES
SU
RE
mm
WG
VOLUME m3/hr
0
2
4
6
8
12
14
16
18
1
23
20
60
100
140
180
108
F
A
B
C
D
E G
D
G
FA
B
C E
G
D
Dimensions - Multi-Vent (Flush Fitting)
Performance - DESIGNER
50 100 150 200 250
7515 30 45 60
A
B
C
D
E
GH
F
Dimensions - CF200
Dimensions - DESIGNER
A B
C
D
Technical Data
Dimensions - Multi-Vent (Surface Mount)
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au54
Models A B C D E F G H I
XPLP125 161 118 128 10 160 125 375 123 30
XPLP150 191 150 132 10 174 150 375 148 30
Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length
XPLP125 140mm White Gravity Shutter Aluminium Semi-Rigid 375mm
XPLP150 173mm White Gravity Shutter Aluminium Semi-Rigid 375mm
GENERAL INFORMATION
DIMENSION INFORMATION
THRU WALL FAN KITS - XPLP Low Profile Models
TECHNICAL SPECIFICATION
Models XPLP125 XPLP150
Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V)
Fan Performance 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 25W
Maximum Pressure 35Pa 60Pa
Fan Speed 2000 rpm 2400 rpm
Sound Level 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC
IP Rating IPX4 IPX4
Performance - XPLP125 Performance - XPLP150
Technical Data
F AB
CD
E
G
H
Dimensions - XPLP
I
Please note: Fan cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 55
Models A B C D E F G H I
XP100 155 98 74 27 138 100 375 98 30
XP125 168 118 74 27 160 125 375 123 30
XP150 200 148 74 27 174 150 375 148 30
XP150A 200 148 90 55 174 150 375 148 30
Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length
XP100 112mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm
XP125 135mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm
XP150 160mm Grey Gravity Shutter Aluminium Semi-Rigid 375mm
GENERAL INFORMATION
DIMENSION INFORMATION
THRU WALL FAN KITS - XP Models
TECHNICAL SPECIFICATION
Performance - XP100 Performance - XP125 Performance - XP150
Models XF100 XF125 XF150
Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V) 220 - 240V (LV models 12V)
Fan Performance 23/s, 85m³/hr 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 20W 25W
Maximum Pressure 20Pa 35Pa 60Pa
Fan Speed 2400 rpm 2000 rpm 2400 rpm
Sound Level 41 dB(A) 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4
Technical Data
F AB
CD
E
G
H
Dimensions - XP
I
Please note: Fan cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au56
Models A B C D
WF100 163 90 30 163
WF150 203 118 23 203
DIMENSION INFORMATION
WINDOW FANS - WF Models
TECHNICAL SPECIFICATION
Performance - WF100 Performance - WF150
Models WF100 WF150
Power 220 - 240V (LV models 12V) 220 - 240V (LV models 12V)
Fan Performance 23/s, 85m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 25W
Maximum Pressure 20Pa 60Pa
Fan Speed 2400 rpm 2400 rpm
Sound Level 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC
IP Rating IPX4 IPX4
AB C
D
Dimensions - WF
Technical Data
Models Glass Cut-Out Size
WF100 115mm - 155mm
WF150 165mm - 190mm
GENERAL INFORMATION
Please note: Glass cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 57
WALL/CEILING & THRU WALL- Commercial XF/XP Models
Performance - XFS230 Performance - XFS300
Models XFS230 XFS300 XPS230 XPS300
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Performance 152l/s, 550m³/hr 306l/s, 1100m³/hr 152l/s, 550m³/hr 306l/s, 1100m³/hr
Fan Wattage 45W 82W 45W 82W
Maximum Pressure 50Pa 60Pa 50Pa 60Pa
Fan Speed 1250 rpm 1300 rpm 1250 rpm 1300 rpm
Sound Level 50 dB(A) 60 dB(A) 50 dB(A) 60 dB(A)
Max. Operating Temp 50oC 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4 IPX4
Models A B C D E F G H I
XFS230 286 230 141 75 66 - - - -
XFS300 362 300 156 81 75 - - - -
XPS230 286 230 141 75 286 250 375 248 30
XPS300 362 300 156 81 350 230 375 298 50
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Technical Data
Models Fan Cut-Out Size Exterior Grille Duct Type Duct Length
XFS230 265mm - - -
XFS300 310mm - - -
XPS230 265mm White Fixed Grille Aluminium Semi-Rigid 375mm
XPS300 310mm White Fixed Grille Aluminium Semi-Rigid 375mm
GENERAL INFORMATION
F AB
CD
E
G
H
Dimensions - XPS230/300
I
Dimensions - XF230/300
A
B
C
D
E
A
Please note: Fan cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au58
WINDOW FANS - Commercial WF/COM
Models A B C D E
WF230 286 286 4-32 112 25
WF300 362 362 4-32 133 29
COM230 286 125 25 154 -
COM300 362 145 25 170 -
50
40
30
20
10
0
0 15 30 45 60 75 80
0 100 150 200 250 300
5
4
3
2
1
0
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
55
40
25
0
55
40
25
0
0 250 500 750
0 70 140 210
0 83 168 250 333 416
6
5
4
3
2
6
5
4
3
2
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
0 300 600 900 1200 1500
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
Performance - COM230
50
40
30
20
10
0
0 15 30 45 60 75 80
0 100 150 200 250 300
5
4
3
2
1
0
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
55
40
25
0
55
40
25
0
0 250 500 750
0 70 140 210
0 83 168 250 333 416
6
5
4
3
2
6
5
4
3
2
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
0 300 600 900 1200 1500
STA
TIC
PR
ES
SU
RE
mm
WG
STA
TIC
PR
ES
SU
RE
PA
VOLUME L/SEC
VOLUME m /hr3
Performance - COM300
Performance - WF230 Performance - WF300
Models WF230 WF300 COM230 COM300
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Performance 152l/s, 550m³/hr 306l/s, 1100m³/hr 185l/s, 670m³/hr 280l/s, 1020m³/hr
Fan Wattage 45W 82W 45W 82W
Maximum Pressure 50Pa 60Pa 50Pa 60Pa
Fan Speed 1250 rpm 1300 rpm 1600 rpm 1300 rpm
Sound Level 50 dB(A) 60 dB(A) 53 dB(A) 60 dB(A)
Max. Operating Temp 50oC 50oC 50oC 50oC
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Technical Data
Dimensions - WF230/300
A
B
C
D E
Models Glass Cut-Out Size
WF230 255mm - 270mm
WF300 310mm - 345mm
COM230 255mm - 270mm
COM300 310mm - 345mm
GENERAL INFORMATION
Dimensions - COM230/300
A
B
C
D
A
Please note: Glass cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 59
Models A B C D
PS Heat ‘n Vent 4 338 338 170 120
PS Heat ‘n Vent 2 435 260 185 120
Heat ‘n Vent 450 250 195 100
Heat ‘n Light 450 250 195 100
Models Cut-Out Size Exterior Grille Duct Type Duct Length
PS Heat ‘n Vent 4 300mm x 300mm White Eggcrate Aluminium 3m supplied (can be extended to 6m)
PS Heat ‘n Vent 2 390mm x 210mm White Eggcrate Aluminium 3m supplied (can be extended to 6m)
Classic Heat ‘n Vent 2 380mm x 200mm White Eggcrate Aluminium 3m supplied (can be extended to 6m)
Classic Heat ‘n Light 390mm x 220mm - - -
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models PS Heat ‘n Vent 4 PS Heat ‘n Vent 2 Heat ‘n Vent 2 2 Heat’n Light
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Centrifugal Centrifugal Centrifugal -
Fan Performance 60l/s, 216m³/hr 50l/s, 180m³/hr 35l/s, 126m³/hr -
Heat Lamps 4 x 275W 2 x 275W 2 x 275W 2 x 275W
Light GU10 Halogen GU10 Halogen ES Bulb ES Bulb
Total Wattage 1180W 635W 670W 650W
Light Wattage 50W 50W 100W 100W
Switch Plate 4 sw. (supplied) 3 sw. (supplied) 3 sw. (supplied) 2 sw. (supplied)
Warranty 5 Years 5 Years 5 Years 5 Years
HEAT/FAN/LIGHT Models
Dimensions - PS Heat ‘n Vent 2
A
B
C
D
Technical Data
Dimensions - PS Heat ‘n Vent 4
A B
C
Dimensions - Classic Heat ‘n Vent
A
B
C
D
Performance
PS Heat ‘n Vent 4PS Heat ‘n Vent 2Heat n Vent 2
Key
Note: Performance tested in free air.
72 144 180 216 252 28810836
70
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au60
Models A B C D E F G
MF100 98 182 315 100 100 168 27
MF125 122 182 350 100 100 168 60
MF150 147 209 360 130 115 195 55
MF200 197 244 354 142 140 230 50
Models Grille Cut-Out
Interior Grille Exterior Grille Duct Type Duct Length
MFLP100 115mm White Low Profile White Low Profile Unilok Nude 6m supplied (can be extended up to 12m)
MFLP125 140mm White Low Profile White Low Profile Unilok Nude 6m supplied (can be extended up to 12m)
MFLP150 160mm White Low Profile White Low Profile Unilok Nude 6m supplied (can be extended up to 12m)
GENERAL INFORMATION (Kits)
DIMENSION INFORMATION (Fans)
TECHNICAL SPECIFICATION
IN-LINE FAN KITS - Mixed Flow Fan Models
Model No Size (mm)
RPM Wattage Maximum Airflow (m³/
hr)
Maximum Pressure
(Pa)
Lp dB(A)3m*
IPRating
Max Operating Temp oC
MF100 100 2300 40 250 200 40 44 45
1700 18 190 120
MF125 125 2300 40 320 230 43 44 45
1700 18 260 160
MF150 150 2700 70 560 360 47 44 60
2000 60 420 320
MF200 200 2700 85 910 300 48 44 60
2350 60 820 225
2000 45 720 150* Lp dB(A) @ 3 metres - sound pressure based on the high speed for each fan
Model No Sound Power Levels Lw (dB)Octave band centre frequency in Hz
LwA dB(A)
125 250 500 1000 2000 4000 8000
MF100 50 56 58 58 52 47 37 61
MF125 52 59 60 60 56 49 41 63.5
MF150 58 66 65 63 62 54 46 67.5
MF200 65 69 64 63 62 60 48 69
Dimensions - MF
Stat
ic P
ress
ure
(Pa)
Airflow m /hr
Airflow l/sFan Speed low high
400
350
300
250
200
150
100
50
0
0 100 200 300 400 500 600 700 800
0 28 56 84 112 140 168 196 224
250
200
150
100
50
0
0 50 100 150 200 250 300
0 14 28 42 56 70 84
Stat
ic P
ress
ure
(Pa)
Airflow m /hr
Airflow l/sFan Speed low high
Stat
ic P
ress
ure
(Pa)
Airflow m /hr
Airflow l/sFan Speed low med high
350
300
250
200
150
100
50
0
0 100 200 300 400 500 600 700 800 900 1000
0 28 56 84 112 140 168 196 224 252 280
Performance - MF100
Performance - MF125
Performance - MF150
Performance - MF200
250
200
150
100
50
0
0 50 100 150 200 250 300 350
0 14 28 42 56 70 84 96
Stat
ic P
ress
ure
(Pa)
Airflow m /hr
Airflow l/sFan Speed low high
SOUND POWER LEVEL (high speed)
Technical Data
Please note: Grille cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 61
Models A B C D E
SFLP125 155 125 125 195 258
SFLP150 200 143 170 185 -
Models Grille Cut-Out Interior Grille Exterior Grille Duct Type Length of Duct included
SFLP125 140mm White Low Profile White Low Profile Flexible Aluminium 4m supplied (can be extended up to 6m)
SFLP150 160mm White Low Profile White Low Profile Flexible PVC 5m supplied (can be extended up to 12m)
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models SFLP125 SFLP150
Fan CFD225 WhisperVent
Power 220 - 240V 220 - 240V
Fan Performance 39l/s, 140m³/hr 94l/s, 340m³/hr
Fan Wattage 20W 46W
Maximum Pressure 120Pa 160Pa
Fan Speed 1400 rpm 2750 rpm
Sound Level 45 dB(A) 38 dB(A)
Max. Operating Temp 50oC 80oC
IP Rating IPX4 IPX2
IN-LINE FAN KITS - SFLP Shower Fan Low Profile Models
Performance - SFLP125
AB CD
E
Dimensions - SFLP125
Performance - SFLP150
72 144 180 216 252 288 324 36010836
70 90
Dimension - SFLP150
A
B
C
D
Technical Data
Please note: Grille cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au62
Models A B C D E
SF100 130 155 90 100 27
SF200 155 100 100 195 258
SF125 150 155 99 118 27
SF150 187 153 109 150 27
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models SF100 SF200 SF125 SF150
Fan ID100 CFD200 ID125 ID150
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Performance 23l/s, 85m³/hr 31l/s, 110m³/hr 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 20W 20W 25W
Maximum Pressure 20Pa 120Pa 35Pa 60Pa
Fan Speed 2400 rpm 1400 rpm 2000rpm 2400 rpm
Sound Level 41 dB(A) 45 dB(A) 41 dB(A) 40 dB(A)
Max Operating Temp 50oC 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4 IPX4
IN-LINE FAN KITS - SF Shower Fan Models
Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.
Dimensions - SF100/SF125/150
A
B
C
D
E
Performance - SF100
Performance - SF125 Performance - SF150Performance - SF200
AB CD
E
Dimensions - SF200
Technical Data
Models Grille Cut-Out Interior Grille Exterior Grille Duct Type Length of Duct included
SF100 115mm White Eggcrate White Fixed Louvre Flexible Alum. 3m supplied (should not be extended)
SF200 115mm White Eggcrate White Fixed Louvre Flexible Alum. 3m supplied (can be extended up to 6m)
SF125 140mm White Eggcrate White Fixed Louvre Flexible PVC 4m supplied (should not be extended)
SF150 160mm White Eggcrate White Fixed Louvre Flexible PVC 5m supplied (can be extended up to 12m)
Please note: Grille cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 63
IN-LINE FAN KITS - ELLP Extract-a-lite Low Profile Models
Technical Data
Models A B C D E F G H
ELLP125 155 125 125 195 258 165 80 110
ELLP150 200 143 170 185 - 200 80 148
Models Diffuser Cut-Out
Interior Exterior Grille Duct Type Length of Duct included
ELLP125W 140mm White Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (can be extended up to 6m)
ELLP125SS 140mm Satin Silver Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (can be extended up to 6m)
ELLP150W 165mm White Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (can be extended up to 12m)
ELLP150SS 165mm Satin Silver Extract-a-lite incl light White Low Profile Black Unilok 6m supplied (can be extended up to 12m)
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models ELLP125 ELLP150
Fan CFD225 WhisperVent
Power 220 - 240V 220 - 240V
Fan Performance 39l/s, 140m³/hr 94l/s, 340m³/hr
Fan Wattage 20W 46W
Maximum Pressure 120Pa 160Pa
Fan Speed 1400 rpm 2750 rpm
Light 12V 50W Halogen 12V 50W Halogen
Total Wattage 99W 96W
Sound Level 45 dB(A) 38 dB(A)
Max. Operating Temp 50oC 80oC
IP Rating IPX4 IPX2
Performance - ELLP125
AB CD
E
Dimensions - ELLP125 Fan
Performance - ELLP150
72 144 180 216 252 288 324 36010836
70 90
Dimensions - ELLP Extract-a-lite Diffuser
F
G
H
Dimension - ELLP150 Fan
A
B
C
D
Please note: Diffuser cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au64
Models A B C D E F G H
EL100 130 98 98 210 270 140 74 98
EL125 150 155 99 118 27 170 74 118
EL150 200 143 170 185 200 74 148
GENERAL INFORMATION
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models EL100 EL125 EL150
Fan CFD200 ID125 ID150
Power 220 - 240V 220 - 240V 220 - 240V
Fan Performance 31l/s, 110m³/hr 36l/s, 130m³/hr 87l/s, 313m³/hr
Fan Wattage 20W 20W 25W
Maximum Pressure 120Pa 35Pa 60Pa
Fan Speed 1400 rpm 2000 rpm 2400 rpm
Light 12V 50W Halogen 12V 50W Halogen 12V 50W Halogen
Total Wattage 95W 75W 75W
Sound Level 45 dB(A) 41 dB(A) 40 dB(A)
Max. Operating Temp 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX2
IN-LINE FAN KITS - EL Extract-a-lite Models
Performance - EL125 Performance - EL150
Technical Data
Models Diffuser Cut-Out
Interior Exterior Grille Duct Type Length of Duct included
EL100 115mm White Extract-a-lite incl light White Eggcrate Flexible PVC 3m supplied (should not be extended)
EL125 140mm White Extract-a-lite incl light White Eggcrate Flexible PVC 4m supplied (should not be extended)
EL150 160mm White Extract-a-lite incl light White Eggcrate Flexible PVC 5m supplied (can be extended up to 12m)
Dimensions - EL125/EL150 Fans
A
B
C
D
E
Dimensions - EL Extract-a-lite Diffuser
F
G
H
AB C D
E
Dimensions - EL100
Performance - EL100
Please note: Diffuser cut out size is a nominal diameter for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 65
Models A B C D
WhisperVent 200 143 170 185
Hyper150 200 143 170 185
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models WhisperVent Hyper150
Power 220 - 240V 220 - 240V
Fan Performance 94l/s, 340m³/hr 89l/s, 320m³/hr
Fan Wattage 46W 38W
Maximum Pressure 160Pa 135Pa
Fan Speed 2750 rpm 2650 rpm
Sound Level 38 dB(A) 46 dB(A)
Max. Operating Temp 80oC 70oC
IP Rating IPX2 IPX2
IN-LINE FANS - WhisperVent/ Hyper150 Fans Models
Performance - WhisperVent
72 144 180 216 252 288 324 36010836
70 90
Performance - Hyper150
72 144 180 216 252 288 324 36010836
70 90
Technical Data
Dimensions
A
B
C
D
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au66
Models A B C D E
ID100 130 155 90 100 27
ID125 150 155 99 118 27
ECO150 (white) 187 153 109 150 27
ID150 187 153 109 150 27
ID230 (square model) 286 286 155 230 -
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
IN-LINE FANS - ID Fan Models
Note: PERFORMANCE - ID Fans maximum fan performance stated, this can vary depending on the length of ducting used.
Dimensions - ID Fans
A
B
C
D
E
Models ID100 ID125 ECO150 ID150 ID230
Power 220 - 240V 220 - 240V 220 - 240V 220 - 240V 220 - 240V
Fan Performance 23l/s, 85m³/hr 36l/s, 130m³/hr 64l/s, 230m³/hr 87l/s, 313m³/hr 152l/s, 550m³/hr
Fan Wattage 20W 20W 25W 25W 80W
Maximum Pressure 20Pa 35Pa 50Pa 60Pa 50Pa
Fan Speed 2400 rpm 2000 rpm 2400 rpm 2400 rpm 1250rpm
Sound Level 41 dB(A) 41 dB(A) 40 dB(A) 40 dB(A) 50dB(A)
Max. Operating Temp 50oC 50oC 50oC 50oC 50oC
IP Rating IPX4 IPX4 IPX4 IPX4 IPX4
Performance - ID100 Performance - ID125
Technical Data
Performance - ID150 Performance - ID230
Performance - ECO150
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 67
TECHNICAL SPECIFICATION
Models CFD200 CFD225
Power 220 - 240V 220 - 240V
Fan Performance 31l/s, 110m³/hr 39l/s, 140m³/hr
Fan Wattage 20W 20W
Maximum Pressure 120Pa 120Pa
Fan Speed 1400 rpm 1400rpm
Sound Level 45 dB(A) 45 dB(A)
Max. Operating Temp 50oC 50oC
IP Rating IPX4 IPX4
IN-LINE FANS - CFD Centrifugal Fans
Models A B C D E
CFD200 155 100 100 195 258
CFD225 155 125 125 195 258
DIMENSION INFORMATION
Dimensions - CFD200/CFD225
AB CD
E
Performance - CFD200 Performance - CFD225
Technical Data
SPECIALISED Fans - Hand Dryers
Model A B C
MAN M-88A 275 225 160
MAN/E-88A 248 284 202
Models MAN M-88A MAN/E-88A
Power 220 - 240V 220 - 240V
Cover ABS Thermoplastic White Steel 2mm Porcelain Enamel
Fan Performance 56l/s, 200m³/hr 130l/s, 470m³/hr
Operation No touch infra-red detection No touch infra-red detection
Power 1.5kW @ 240V 2.4kW @ 240V
Sound Level 54 dB(A) 70 dB(A)
Weight 3.3kg 7.5kg
TECHNICAL SPECIFICATION
DIMENSION INFORMATION
Dimensions - M-88A Dimensions - E-88A
DepthDepth
A
B
C
A
B
C
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au68
IN-LINE FANS - High Performance Centrifugal Models
Technical Data
Models A B C D E
MAN100 250 100 136 50 70
MAN125 250 125 147 60 60
MAN150 340 150 154 50 75
MAN200 340 200 154 50 75
MAN250 320 249 310 65 65
MAN315 405 315 177 80 80
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models MAN100 MAN125 MAN150 MAN200 MAN250 MAN315
Voltage/Freq (50hz) 220~240V 220~240V 220~240V 220~240V 220~240V 220~240V
Fan Performance 49l/s, 176m³/hr
61l/s, 220m³/hr
115l/s, 415m³/hr
208l/s, 750m³/hr
280l/s, 1010m³/hr
360l/s, 1300m³/hr
Fan Wattage 32W 31W 65W 110W 170W 200W
Maximum Pressure 153Pa 143Pa 320Pa 418Pa 500Pa 590Pa
Current (A) 0.14 0.13 0.35 0.45 0.76 0.87
Fan Speed (min-1) 2500 rpm 2490 rpm 2350 rpm 2520 rpm 2580 rpm 2410 rpm
Sound Level* 38 dB(A) 38 dB(A) 50 dB(A) 56 dB(A) 47 dB(A) 57 dB(A)
Max Operating Temp 60oC 60oC 50oC 60oC 50oC 45oC
0 10 20 30 40 50 60 70
0 50 100 150 200 250
160
140
120
100
80
60
40
20
0
125mm
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)
Volume l/s
Performance - MAN125
Volume l/s
0 20 40 60 80 100 120
350
300
250
200
150
100
50
0
0 50 100 150 200 250 300 350 400
150mm
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)Performance - MAN150
* dB(A) - measured 1m free field/3m 20m²Sabine
0 50 100 150 200 250 300
500
450
400
350
300
250
200
150
100
50
0
0 200 400 600 800 1000
250mm
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)
Volume l/s
Performance - MAN250
0 10 20 30 40 50
0 20 40 60 80 100 120 140 160 180
100mm
Volume l/s
Performance - MAN100
160
140
120
100
80
60
40
20
0
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)
0 50 100 150 200
250 Volume l/s
450
400
350
300
250
200
150
100
50
0
0 100 200 300 400 500 600 700 800 900
200mm
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)Performance - MAN200
0 50 100 150 200 250
0 50 100 150 200 250 300 350 400
600
500
400
300
200
100
0
0 200 400 600 800 1000 1200 1400
315mm
Sta
tic P
ress
ure
(Pa)
Volume (m3/h)
Volume l/s
Performance - MAN315
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 69
IN-LINE FANS - Three Speed Centrifugal Models
Technical Data
Models A B C D E
150mm 340 150 154 50 75
200mm 340 200 154 50 75
DIMENSION INFORMATION
TECHNICAL SPECIFICATION
Models 150mm 200mm
Voltage/Freq (50hz) 220~240V 220~240V
Fan Performance Speed 1 65l/s, 234m³/hr 125l/s, 450m³/hr
Fan Performance Speed 2 90l/s, 324m³/hr 170l/s, 620m³/hr
Fan Performance Speed 3 124l/s, 425m³/hr 205l/s, 740m³/hr
Fan Wattage (at high speed) 65W 110W
Current (A) (at high speed) 0.36 0.38
Fan Speed (at high speed) 2460 rpm 2700 rpm
Sound Level* 43 dB(A) 56 dB(A)
Ambient Temp 50oC 60oC
* dB(A) - measured 1m free field/3m 20m² Sabine
Performance - 150mm 3 Speed400
300
200
100
Pres
sure
(Pa)
100 200 300 400 500 600 700 800 900 1000
Airflow (m3/hr)
200mm 3 Speed Centrifugal Fan CurvePerformance - 200mm 3 Speed
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au70
IN-LINE FANS - WhisperVent Low Profile Models
Models Fan Speed Fan PerformanceNorm
Fan Speed (RPM)
Single Phase
Nom Watts Nom Amps
FAN0830 1 65l/s, 234m³/hr 1440 50 0.22FAN0830 2 90l/s, 324m³/hr 1860 56 0.24
FAN0830 3 124l/s, 445m³/hr 2460 80 0.36
FAN0829 1 118l/s, 425m³/hr 2520 80 0.36
TECHNICAL SPECIFICATION
Models A B C D E
WhisperVent Low Profile
313 168 148 340 218
DIMENSION INFORMATION
A
B Ø C
D
E
Performance - FAN0829 & FAN0830
Technical Data
Model NoSound Power Levels Lw (A)
Octave band centre frequency in Hz dB(A) @ 3m
63 125 250 500 1k 2k 4k 8k
FAN0830 - Speed 1 - 20 34 43 43 44 40 30 30
FAN0830 - Speed 2 - 26 40 51 51 52 45 38 36
FAN0830 - Speed 3 - 40 42 62 64 64 59 45 43
FAN0829 57 61 68 67 65 64 59 53 43
SOUND POWER LEVEL - Lw(A)
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 71
Externally Mounted Extract Fans
Order Code Motor Size (mm)
Description Fan Performance Watts @ 230V
Amps Static Pressure (Pa)
Sound Level (dB(A) @ 3m)m³/hr l/s
FAN2303 150 AXIAL 263 73 48 0.29 80 48
FAN2301 150 CENTRIFUGAL 190 MOTOR (1 SPEED) 392 109 65 0.28 280 60
FAN2302 150 CENTRIFUGAL 220 MOTOR (1 SPEED) 480 133 96 0.42 380 61
FAN2316 150 CENTRIFUGAL 190 MOTOR (3 SPEED)
HIGH SPEED 408 113 65 0.28 280 60
MEDIUM SPEED 340 94 57 0.25 250 56
LOW SPEED 277 77 55 0.24 200 46
FAN2317 150 CENTRIFUGAL 220 MOTOR (3 SPEED)
HIGH SPEED 493 136 96 0.42 380 61
MEDIUM SPEED 408 113 69 0.34 340 56
LOW SPEED 340 94 60 0.31 280 50
PERFORMANCE DATA
Fan Assembly - Line Drawing
Technical Data
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au72
Technical Data
THRU ROOF Models
Models A B C
DCT0708 275 125 -
DCT0709 275 140 -
FAN1009 275 170 -
FAN0531- FAN0533 275 170 -
FAN0530 - FAN0967 275 170 500
FAN1060 275 170 500
FAN0532 - FAN0534 275 170 500
A
B
C
Dimensions - Thru Roof Fan Kits
TECHNICAL SPECIFICATION³²
DIMENSION INFORMATION
Models FAN0529FAN0530
FAN1002FAN0967
FAN0531FAN0532
FAN0533FAN0534
FAN1009FAN1060
Supply Voltage 220-240VAC 220-240VAC 220-240VAC 220-240VAC 220-240VAC
Fan Centrifugal Centrifugal Axial Axial Axial - Whisper
Fan Performance 130l/s, 468m³/hr 130l/s, 468m³/hr 80l/s, 288m³/hr 80l/s, 288m³/hr 89l/s, 320m³/hr
Fan Wattage 58W 58W 38W 38W 46W
Maximum Pressure 325Pa 325Pa 135Pa 135Pa 160Pa
Fan Speed 2500rpm 2500rpm 2850rpm 2850rpm 2750rpm
Sound Level @ 1m 62db(A) 62db(A) 55db(A) 55db(A) 38db(A)
Operating Temp -25 - +50° -25 - +50° -20 - +80° -20 - +80° -20 - +80°
IP Rating IPX4 IPX4 IPX2 IPX2 IPX2
FAN0531/FAN0532150mm Axial ExtractPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
60
50
40
30
20
10
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ductin
Performance - FAN0531/FAN0532FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
Performance - FAN0533/FAN0534FAN0533/FAN0534
150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
Pres
sure
(Pa)
Volume (litre/sec)
60
50
40
30
20
10
00 50 60 70 80 90 100
Operating Point
Operating Point- 3m flexible ducting
- free air
Performance - FAN1009/FAN1060
FAN0529/FAN0530150mm Centifugal
Pressure vs Volume250
200
150
100
50
0
Pre
ssur
e (P
a)
0 50 100 150 200 250
Volume (litre/sec)
Operating Point - free air
Operating Point - 3m flexible ducting
Performance - FAN0529/FAN0530
FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
FAN0533/FAN0534150mm Axial SupplyPressure vs Volume
Pre
ssur
e (P
a)
Volume (litre/sec)
90
75
60
45
30
15
0
0 50 60 70 80 90 100
Operating Point - free air
Operating Point - 3m flexible ducting
* NOTE: All fan flow rates quoted are motor performance in free air.
DCT0708 and DCT0709Pressure vs Volume
100
80
60
40
20
0
Pre
ssur
e (P
a)
0 50 100 150 200 250
Volume (litre/sec)
Performance - DCT0708/DCT0709
B
A
A
B
Dimensions - DCT0708
Dimensions - DCT0709
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 73
Technical Data
Models A B C D E F
BSL112 140 90 52 12 98 38
BSL124 140 90 52 10 98 38
SPECIALISED Fans - DC Extract-a-lite Model
Performance - DC Extract-a-liteModels DC Extract-a-lite
Power 12V or 24V
Fan Performance 18l/s, 64m³/hr
Fan Wattage 45W
Maximum Pressure 125Pa
Fan Speed 1400 rpm
Sound Level 45 dB(A)
Max. Operating Temp 40oC
IP Rating IPX4
TECHNICAL SPECIFICATION
DIMENSION INFORMATION
Dimensions - DC Extract-a-lite
BE
F
A
C
D
A
SPECIALISED Fans - Frame Fan AC Model
Models A B C D
Frame Fan 125 120 120 105 40
Frame Fan 150 172 150 160 51
Models Frame Fan 125 Frame Fan 150
Power 220 - 240V 220 - 240V
Fan Performance 38l/s, 138m³/hr 89l/s, 320m³/hr
Fan Wattage 15W 38W
Maximum Pressure 62Pa 135Pa
Fan Speed 2650 rpm 2650 rpm
Sound Level 43 dB(A) 46 dB(A)
Max. Operating Temp 80oC 70oC
IP Rating IPX4 IPX2
TECHNICAL SPECIFICATION
DIMENSION INFORMATION
Performance - 125mm Frame Fan
Performance - 150mm Frame Fan
72 144 180 216 252 288 324 36010836
70 90
A
B
CD
Dimensions - Frame Fan
Dimensions - DCT0708
Dimensions - DCT0709
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au74
Technical Data
Installation and UsageInstall duct fully extended, do not install in the compressed state or use excess lengths. This will noticeably increase friction losses.
RIGHT WRONG
STEAM PIPES
The layout of flexible duct, the number of bends, the sharpness of the bend and the amount of sag allowed between support joints will have serious effects on system performance due to the increased resistance to airflow each introduces. Use the minimum length of flexible duct to make connections. It is not recommended that excess length of ducts be installed to allow for possible future relocations of air terminal devices.
Avoid installation where exposure to direct sunlight can occur eg: skylight. Grilles and diffusers need to be supported independently of the flexible duct.Repair torn or damaged vapour barrier/jacket with duct tape listed and labelled to Standard AS4254. If internal core is penetrated, replace flexible duct or treat as a join.
Avoid bending ducts across sharp corners or incidental contact with metal fixtures, pipes or conduits. Flexible ducts shall be installed with a bend radius to duct diameter ratio in accordance with the following:
Do not install near hot equipment (eg heaters boilers, steam pipes etc.) that is above the recommended flexible duct use temperature.
Duct velocity R/D ratio centerline radius to duct diameter:
eg: Assuming duct velocity of 8m/s
Ducting Installation Guidelines
Up to 5m/s x 0.6 8m/s x 1.0 Above 8m/s x 1.5
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 75
Technical Data
CONNECTIONS JOINS
Installation Instructions for Air Ducts and Air Connectors:Non Metallic with Plain Ends
1. After desired length is determined, cut completely around and through duct with knife or scissors. Cut wire with wire cutters. Fold back duct jacket and insulation.
1. Fold back duct jacket and insulation from core. Butt two cores together on a 4” (100mm) length metal sleeve or polymer sleeve.
2. Slide at least 1” (25mm) of core over the fitting up to the bead. Seal the core to collar with at least 2 wraps of duct tape. Secure connection with clamp placed over the core and duct tape.
2. Tape cores together with at least 2 wraps of duct tape. Connection can be secured with 2 clamps placed over the taped core ends.
3. Pull jacket and insulation back over core. Tape jacket with at least 2 wraps of duct tape ensuring end of the outer jacket is secured to the spigot. A clamp may be used in place of or in combination with the duct tape.
3. Pull jacket and insulation back over cores. Tape jackets together with at least 2 wraps of duct tape.
Ducting Installation Guidelines
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au76
Technical Data
Factory installed suspension systems integral to the flexible duct is an acceptable hanging method
WIRE
Hanger or saddle material in contact with the flexible duct shall be of sufficient width to prevent any restriction of the internal diameter of the duct when the weight of the supported section rests on the hanger or saddle material. In no case will the material contacting the flexible duct be less than 40mm wide.
40mm Min.
40mm Min.
Flexible duct shall be supported at intervals, no greater distance than 1.5m. Maximum permissable sag is 40mm per metre of spacing between supports.
A connection to rigid duct or equipment shall be considered a support joint. Long horizontal duct runs with sharp bends shall have additional supports before and after the bend approximately one duct diameter from the centre line of the bend.
Recommend Hanging Straps DCT0808
SAG 60mm
Supporting Flexible Duct
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 77
Technical Data
Flexible ducts may rest on ceiling joists or truss supports. Maximum spacing between supports shall not exceed 1.5m.
NOTE: factory-made air ducts may not be used for vertical risers in air duct systems serving more than two stories
CEILING JOIST
Vertically installed duct shall be stabilised by support straps at a max of 1.8m
Support the duct between a metal connection and bend by allowing the duct to extend straight for 100mm before making the bend. This will avoid possible damage of the flexible duct by the edge of the metal collar.
NOTE: Upon completion of installation, please test in accordance with 2.8.2 of standard AS4254.
Supporting Flexible Duct
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au78
Technical Data
40 Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
Flexible Ducting Friction Loss Graph
Technical Data
Friction Loss (Pa per metre)
Air
Vo
lum
e m
3 /h
(m3 /
h /
3.6
= l/s
)
40 Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
Flexible Ducting Friction Loss Graph
Technical Data
Friction Loss (Pa per metre)
Air
Vo
lum
e m
3 /h
(m3 /
h /
3.6
= l/s
)
40 Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
Flexible Ducting Friction Loss Graph
Technical Data
Friction Loss (Pa per metre)
Air
Vo
lum
e m
3 /h
(m3 /
h /
3.6
= l/s
)
Flexible Ducting Friction Loss Graph
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 79
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
cut-out Size*(mm)
Ceiling/Wall Grille 150 DCT2224 191 x 191 150 65 157
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Circular Ceiling Grille 100 DCT2185 140 98 49 105
Circular Ceiling Grille 125 DCT2186 170 125 65 125
Circular Ceiling Grille 150 DCT2187 200 150 65 157
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Circular Grille 100 DCT1089 140 98 49 115
Circular Grille 125 DCT1090 170 120 65 135
Circular Grille 150 DCT1067 200 150 65 165
Square Grille 100 DCT2223 140 x 140 98 49 115
Square Grille 125 DCT2224 161 x 161 120 65 135
Square Grille 150 DCT2225 191 x 191 150 65 165
Technical Data
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Fixed Louvre Grille 100 DCT0025 140 x 140 100 35 105
Fixed Louvre Grille 125 DCT0041 162 x 162 122 25 127
Fixed Louvre Grille 150 DCT0063 174 x 174 152 32 157
Fixed Louvre Grille 200 DCT0340 285 x 285 199 67 240
Fixed Louvre Grille 230/250 DCT0073 285 x 285 230 29 240
Fixed Louvre Grille 300 DCT1979 350 x 350 285 50 295
Eggcrate Grille 100 DCT0375 140 x 140 100 34 105
Eggcrate Grille 125 DCT0472 162 x 162 122 24 127
Eggcrate Grille 150 DCT0473 175 x 175 152 34 157
Square Wall/Ceiling Grille
Circular Ceiling Grilles
Low Profile Wall/Ceiling Grilles
Fixed Wall/Ceiling Grilles
*Please note: All cut-out sizes listed are nominal diameters for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au80
Technical Data
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size*(mm)
WhisperVent Cone Diffuser 150 DCT1472 266 150 95 232
WhisperVent Cone Diffuser 200 DCT1473 317 200 95 282
WhisperVent Cone Diffuser 250 DCT1474 389 250 102 355
WhisperVent Cone Diffuser 300 DCT1475 400 300 102 405
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size*(mm)
Eco Ceiling Diffuser 100 DCT0020 149 99 47 98
Eco Ceiling Diffuser 125 DCT0174 169 125 47 123
Eco Ceiling Diffuser 150 DCT0058 186 148 50 148
Eco Ceiling Diffuser 200 DCT0068 235 198 50 198
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Stainless Steel Diffuser 100 DCT2139 140 97 52 105
Stainless Steel Diffuser 125 DCT2140 172 120 52 130
Stainless Steel Diffuser 150 DCT2141 220 145 62 150
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
*cut-out Size (mm)
Flat Ceiling Diffuser 150 DCT2208 220 148 80 210
Stainless Steel Ceiling Diffuser
‘ECO’ Ceiling Diffuser
Low Profile Flat Ceiling Diffuser
WhisperVent Cone Ceiling Diffuser
*Please note: All cut-out sizes listed are nominal diameters for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 81
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size*(mm)
Designer Weatherproof 100 DCT2151 150 x 150 97 52 115
Designer Weatherproof 125 DCT2152 180 x 180 120 52 140
Designer Weatherproof 150 DCT2153 180 x 180 145 62 160
Standard Weatherproof 100 DCT0018 105 x 105 99 35 105
Standard Weatherproof 125 DCT1030 127 x 127 122 27 125
Standard Weatherproof 150 DCT1031 127 x 127 150 35 152
Grille Description Metric Size (mm)
Order Code
Face Size(mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Designer Dome Cowl 100 DCT2157 140 97 52 115
Designer Dome Cowl 125 DCT2158 180 120 52 140
Designer Dome Cowl 150 DCT2159 200 145 62 155
Technical Data
Grille Description Metric Size (mm)
order code
Face Size (mm)
Spigot Diameter
(mm)
Spigot length (mm)
Cut-Out Size* (mm)
Designer Gravity Grille 100 DCT2145 150 x 150 97 52 115
Designer Gravity Grille 125 DCT2146 180 x 180 120 52 140
Designer Gravity Grille 150 DCT2147 180 x 180 145 62 160
Standard Gravity Grille 100 DCT0029 140 x 140 100 35 105
Standard Gravity Grille 125 DCT0044 162 x 162 122 25 127
Standard Gravity Grille 150 DCT0066 174 x 174 152 32 157
Standard Gravity Grille 230/250 DCT2204 285 x 285 230 29 240
Standard Gravity Grille 300 DCT1981 350 x 350 285 50 295
The Designer Gravity Grille requires a minimum pressure to open• 20Pa - 100mm (DCT2145)• 30Pa - 125mm (DCT2146)• 30Pa - 150mm (DCT2147)
The Designer Weatherproof Cowl requires a minimum pressure to open• 10Pa - 100mm (DCT2151)• 10Pa - 125mm (DCT2152)• 10Pa - 150mm (DCT2153)
Gravity Wall Grilles
Weatherproof Cowl
Weatherproof Dome Cowl
*Please note: All cut-out sizes listed are nominal diameters for a circular cut-out
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au82
Fan Index PageOrder Code
Product Page
Technical Page
DCT0013 33 -
DCT0014 34 -
DCT0015 35 -
DCT0016 36 -
DCT0018 42 81
DCT0019 42 81
DCT0020 40 80
DCT0024 38 80
DCT0025 38 80
DCT0026 38 80
DCT0027 38 81
DCT0028 38 81
DCT0029 38 81
DCT0036 45 -
DCT0037 37 -
DCT0039 38 80
DCT0040 38 80
DCT0041 38 80
DCT0042 38 81
DCT0043 38 81
DCT0044 38 81
DCT0058 40 80
DCT0059 37 -
DCT0061 38 81
DCT0062 38 79
DCT0063 38 79
DCT0064 38 79
DCT0065 38 81
DCT0066 38 81
DCT0068 40 80
DCT0071 37 -
DCT0073 38 79
DCT0084 37 -
DCT0084 37 -
DCT0088 31 78
DCT0089 31 78
DCT0091 37 -
DCT0114 32 -
DCT0115 32 -
DCT0116 32 -
DCT0117 32 -
DCT0118 32 -
DCT0119 32 -
DCT0120 32 -
DCT0124 35 -
DCT0125 35 -
DCT0126 35 -
DCT0127 34 -
DCT0131 34 -
DCT0134 35 -
DCT0136 34 -
DCT0137 36 -
DCT0145 33 -
DCT0146 33 -
DCT0147 33 -
DCT0148 36 -
DCT0149 36 -
DCT0150 36 -
DCT0151 33 -
DCT0152 33 -
DCT0153 33 -
DCT0159 37 -
DCT0172 43 -
DCT0173 45 -
DCT0174 40 80
DCT0180 45 -
DCT0183 45 -
DCT0189 26 72
DCT0190 45 -
DCT0207 45 -
DCT0208 45 -
DCT0328 31 78
DCT0329 31 78
DCT0330 31 78
DCT0331 31 78
DCT0332 31 78
DCT0333 32 -
DCT0334 32 -
DCT0335 32 -
DCT0336 32 -
DCT0337 32 -
DCT0338 32 -
DCT0339 37 -
DCT0340 38 79
DCT0343 31 78
DCT0357 31 78
DCT0358 31 78
DCT0359 31 78
DCT0360 21 -
DCT0362 21 -
DCT0366 21 -
DCT0371 45 -
DCT0373 45 -
DCT0375 38 79
DCT0380 31 78
DCT0399 31 78
DCT0401 31 78
DCT0403 31 78
DCT0405 31 78
DCT0409 31 78
DCT0410 31 78
DCT0411 31 78
DCT0412 31 78
DCT0413 31 78
DCT0414 31 78
DCT0415 31 78
DCT0416 31 78
DCT0417 31 78
DCT0418 31 78
DCT0448 34 -
DCT0460 37 -
DCT0472 38 79
DCT0473 38 79
DCT0477 32 -
DCT0486 37 -
DCT0511 45 -
DCT0519 33 -
DCT0520 34 -
DCT0521 35 -
DCT0522 35 -
DCT0523 35 -
DCT0524 35 -
DCT0525 35 -
DCT0526 34 -
DCT0527 35 -
DCT0528 36 -
DCT0633 31 -
DCT0634 31 -
DCT0635 31 -
DCT0636 31 -
DCT0708 43 72
DCT0709 43 72
DCT0710 43 -
DCT0719 37 -
DCT0723 37 -
DCT0724 37 -
DCT0725 37 -
DCT0807 45 -
DCT0808 45 -
DCT0875 37 -
DCT0876 37 -
DCT0877 37 -
DCT0935 37 -
DCT0936 32 -
DCT0937 32 -
DCT0938 32 -
DCT0939 37 -
DCT0940 37 -
DCT0953 33 -
DCT0954 33 -
DCT1030 42 81
DCT1031 42 81
DCT1067 39 79
DCT1074 39 -
DCT1076 39 -
DCT1089 41 79
DCT1090 39 79
DCT1095 43 -
DCT1097 27 -
DCT1114 34 -
DCT1132 45 -
DCT1169 21 -
DCT1171 21 -
DCT1414 36 -
DCT1424 33 -
DCT1425 33 -
DCT1426 33 -
DCT1439 37 -
DCT1440 35 -
DCT1441 35 -
DCT1442 34 -
DCT1443 33 -
DCT1444 35 -
DCT1445 35 -
DCT1446 34 -
DCT1447 35 -
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 83
Index Page
DCT1448 35 -
DCT1450 36 -
DCT1451 36 -
DCT1452 34 -
DCT1453 36 -
DCT1455 35 -
DCT1456 34 -
DCT1458 35 -
DCT1459 34 -
DCT1460 33 -
DCT1461 34 -
DCT1472 41 80
DCT1473 41 80
DCT1474 41 80
DCT1475 41 80
DCT1479 34 -
DCT1480 35 -
DCT1481 49 -
DCT1482 34 -
DCT1501 37 -
DCT1519 20 -
DCT1520 20 -
DCT1521 20 -
DCT1522 20 -
DCT1979 38 79
DCT1981 38 81
DCT2066 43 -
DCT2066 37 -
DCT2067 37 -
DCT2092 45 -
DCT2095 35 -
DCT2096 35 -
DCT2097 35 -
DCT2098 35 -
DCT2099 35 -
DCT2101 49 -
DCT2120 21 -
DCT2121 21 -
DCT2122 43 -
DCT2122 37 -
DCT2139 41 80
DCT2140 41 80
DCT2141 41 80
DCT2145 38 81
DCT2146 38 81
DCT2147 38 81
DCT2151 42 81
DCT2152 42 81
DCT2153 42 81
DCT2157 42 81
DCT2158 42 81
DCT2159 42 81
DCT2185 40 79
DCT2186 40 79
DCT2187 40 79
DCT2188 40 -
DCT2189 40 -
DCT2190 40 -
DCT2191 40 -
DCT2192 40 -
DCT2193 40 -
DCT2194 40 -
DCT2195 40 -
DCT2196 40 -
DCT2197 40 -
DCT2198 40 -
DCT2199 40 -
DCT2204 38 81
DCT2205 43 -
DCT2206 35 -
DCT2208 41 80
DCT2223 39 79
DCT2224 39 79
DCT2225 39 79
DCT2236 39 -
DCT2237 39 -
DCT2263 45 -
DCT2299 45 -
DCT2323 44 -
DCT2324 44 -
DCT2325 44 -
DCT2592 44 -
FAN0012 23 66
FAN0013 23 66
FAN0015 30 -
FAN0016 30 -
FAN0017 19 62
FAN0018 19 62
FAN0021 17 56
FAN0038 14 53
FAN0041 14 53
FAN0042 14 53
FAN0044 13 52
FAN0046 13 52
FAN0047 13 52
FAN0048 13 52
FAN0053 16 55
FAN0054 16 55
FAN0055 16 55
FAN0060 23 66
FAN0061 23 66
FAN0064 19 62
FAN0065 19 62
FAN0071 13 52
FAN0072 13 52
FAN0074 13 52
FAN0075 13 52
FAN0080 16 55
FAN0082 16 55
FAN0083 16 55
FAN0085 22 65
FAN0090 23 66
FAN0091 23 66
FAN0101 19 62
FAN0102 19 62
FAN0107 17 56
FAN0109 17 56
FAN0110 17 56
FAN0119 13 52
FAN0120 13 52
FAN0121 13 52
FAN0122 13 52
FAN0123 13 52
FAN0124 13 52
FAN0126 13 52
FAN0127 13 52
FAN0135 16 55
FAN0136 16 55
FAN0137 16 55
FAN0138 16 55
FAN0140 16 55
FAN0141 16 55
FAN0146 17 58
FAN0148 17 58
FAN0153 30 -
FAN0155 30 -
FAN0156 30 -
FAN0157 30 -
FAN0159 42 -
FAN0213 45 -
FAN0274 45 -
FAN0281 45 -
FAN0282 45 -
FAN0325 48 -
FAN0326 23 67
FAN0327 23 67
FAN0328 19 62
FAN0329 19 62
FAN0330 24 68
FAN0337 48 -
FAN0338 48 -
FAN0346 13 57
FAN0348 16 57
FAN0355 17 56
FAN0357 24 68
FAN0358 24 68
FAN0360 24 68
FAN0361 24 68
FAN0372 29 -
FAN0374 13 57
FAN0397 28 73
FAN0400 45 -
FAN0405 23 66
FAN0406 23 66
FAN0409 16 55
FAN0410 16 55
FAN0411 16 55
FAN0412 28 -
FAN0413 28 -
FAN0420 21 64
FAN0431 20, 21 -
FAN0438 21 64
FAN0452 17 56
FAN0455 16 57
FAN0467 24 68
FAN0481 17 58
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au84
FAN0482 17 58
FAN0499 14 53
FAN0501 14 53
FAN0504 14 53
FAN0505 14 53
FAN0518 17 58
FAN0519 17 58
FAN0520 17 58
FAN0521 17 58
FAN0529 26 72
FAN0530 26 72
FAN0531 26 72
FAN0532 26 72
FAN0533 26 72
FAN0534 26 72
FAN0535 26 72
FAN0589 12 51
FAN0590 12 51
FAN0591 12 51
FAN0594 12 51
FAN0595 12 51
FAN0596 12 51
FAN0598 12,15 -
FAN0604 12 51
FAN0605 12 51
FAN0606 12 51
FAN0609 12 51
FAN0610 12 51
FAN0611 12 51
FAN0613 12,15 -
FAN0614 15 54
FAN0615 15 54
FAN0616 19 61
FAN0617 19 61
FAN0618 19 61
FAN0619 19 61
FAN0620 15 54
FAN0621 15 54
FAN0623 15 54
FAN0625 27 73
FAN0626 27 73
FAN0644 39 -
FAN0656 39 -
FAN0685 27 73
FAN0686 27 73
FAN0690 27 73
FAN0691 27 73
FAN0732 15 54
FAN0735 15 54
FAN0738 15 54
FAN0748 39 -
FAN0748 39 -
FAN0749 39 -
FAN0750 39 -
FAN0755 12,15 -
FAN0757 12,15 -
FAN0784 39 -
FAN0803 21 64
FAN0804 21 64
FAN0827 21 -
FAN0829 24 70
FAN0830 24 70
FAN0841 28 -
FAN0884 14 53
FAN0885 14 53
FAN0916 22 65
FAN0921 24 69
FAN0940 18 59
FAN0963 29 -
FAN0967 26 72
FAN0981 30 -
FAN0982 30 -
FAN0983 30 -
FAN0995 18 59
FAN0997 24 69
FAN1002 26 72
FAN1004 22 60
FAN1005 22 60
FAN1006 22 60
FAN1007 22 60
FAN1009 26 72
FAN1014 18 -
FAN1015 18 -
FAN1043 28 73
FAN1044 28 -
FAN1060 26 72
FAN1048 22 60
FAN1050 22 60
FAN1051 22 60
FAN1053 22 60
FAN1096 30 -
FAN2029 20 63
FAN2030 20 63
FAN2031 20 63
FAN2032 20 63
FAN2033 20 63
FAN2034 20 63
FAN2035 20 63
FAN2036 20 63
FAN2037 21 64
FAN2038 21 64
FAN2040 13 57
FAN2041 13 57
FAN2042 16 57
FAN2043 16 57
FAN2049 19 60
FAN2050 19 60
FAN2051 19 60
FAN2066 23 67
FAN2067 23 67
FAN2068 12,15 -
FAN2069 15 -
FAN2070 12,15 -
FAN2071 12,15 -
FAN2076 21 -
FAN2078 23 66
FAN2101 20, 21 -
FAN2104 30 -
FAN2124 22 60
FAN2125 22 60
FAN2126 22 60
FAN2127 22 60
FAN2162 18 59
FAN2200 18 59
FAN2301 25 71
FAN2302 25 71
FAN2303 25 71
FAN2316 25 71
FAN2317 25 71
FAN2402 29 -
FAN2902 28 67
FAN2903 28 67
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Order Code
Product Page
Technical Page
Fan Index Page
LHT0081 18 -
LHT0140 18 -
Order Code
Product Page
Technical Page
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 85
Notes
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au86
Notes
Ph: 1300 666 595 • Fax: 1300 666 594 • Email: [email protected] • Website: www.manrose.com.au 87
Notes
Energy Efficient Ventilation Solutions
Lo-Carbon
Lo Carbon fans from Vent Axia offer up to 87% energy savings by utilising market leading motor technology,
to help reduce your carbon footprint.
Lo-Carbon
Lo-Carbon Silhouette 150
Lo-Carbon Vent-a-Light 100
Lo-Carbon Silhouette 100
Vent-Axia Lo-Carbon long life motors last 5
times longer than conventional AC motors.
The extended life of the Lo-Carbon fans is due
to the use of a new generation of high quality
ball bearing motor.
These high quality ventilation fans are
specifically designed for bathrooms, extracting
moisture laden air quietly & effectively.
Thomas & Betts are proud to be the distributor of the Vent-Axia Lo-Carbon range of ventilation fans.Lo-Carbon fans from Vent-Axia offer up to 87% energy savings by utilising market leading motor technology, to help reduce your carbon footprint.
Lo-Carbon
NEW
NEW
NEW
National Support Centre
Phone: 1300 666 595
Fax: 1300 666 594
Email: [email protected]
Suite 3, Level 7, 3 Rider Boulevard Rhodes NSW 2138
Western AustraliaUnit 2, 22 Hammond Rd Cockburn Central WA 6164
Victoria2/13-15 Brough St Springvale VIC 3171
TasmaniaElectrical Agencies 4 Linear Court Moonah TAS 7009
South Australia86A Richmond Rd Keswick SA 5035
Queensland26 Turbo Drive Cooparoo QLD 4151
NewcastleNick Webb Agencies Unit 5, 21 Babilla Close Beresfield NSW 2322
Lo-Carbon
Ph:1300666595•Fax:1300666594•Email:[email protected]•Website:www.manrose.com.au
• 17mm stylish low profile grille• Quiet running • 1 of 2 speeds selectable at installation
• High quality ball bearing motors• Fan IPX4 rated• 5 Year Warranty
• Suitable for shower enclosure and wet areas• Provides simultaneous fan and light operation
• Complete with ducting & exterior grille• Supplied with chrome and white bezel• IP44 rated fan• 5 Year warranty
Lo-Carbon Silhouette 100Up to 87% energy savings in power consumption
Lo-Carbon Silhouette fans use lower wattage motors 2 - 7.5W versus 20W in a traditional 100mm AC model.
Lo-Carbon Vent-a-Light 100Up to 84% energy savings on the fan motor*
Lo-Carbon Vent-a-Light fans use lower wattage motors 6.5W versus 40W in a traditional Fan/Light AC model.
87% energy savings
84% energy savings
“The extended life of the Lo-Carbon fans is due to the use of a new generation of high quality ball bearing motor”
“Vent-Axia Lo-Carbon long life motors last 5 times longer than conventional motors whilst delivering up to 87% energy savings”
100mm
• 19mm stylish low profile grille• Quiet running • Downstream airflow guide vanes for improved pressure development
• 1 of 2 speeds selectable at installation • High quality ball bearing motors• Fan IPX4 rated • 5 Year Warranty
Lo-Carbon Silhouette 150Up to 60% energy savings in power consumption
Lo-Carbon Silhouette fans use lower wattage motors 5 - 8.2W versus 25W in a traditional 150mm AC model.
60% energy savings
150mm
* Please note the energy savings only apply to the fan motor
100mm
Model Extract Performance Watts Switching Order Code
High Speed
Low Speed
High Speed
Low Speed
(m³/hr) l/s (m³/hr) l/s (W) (W)
Silhouette 100B 95 26 60 16 6 2 Standard FAN2205
Silhouette 100T 95 26 60 16 6 2 Timer FAN2206
Silhouette 100LV 95 26 60 16 7.5 3.5 Low Voltage FAN2207
Silhouette 100LVT 95 26 60 16 7.5 3.5 Low Voltage Timer
FAN2208
Model Extract Performance Watts Switching Order Code
High Speed
Low Speed
High Speed
Low Speed
(m³/hr) l/s (m³/hr) l/s (W) (W)
Silhouette 100B 241 67 165 46 8.2 5 Standard FAN2213
Silhouette 100T 241 67 165 46 8.2 5 Timer FAN2214
Silhouette 100LV 241 67 165 46 8.2 5 Low Voltage FAN2215
Silhouette 100LVT 241 67 165 46 8.2 5 Low Voltage Timer
FAN2216
Model Extract Performance Watts Switching Order Code
High Speed
High Speed
Low Speed
(m³/hr) l/s (W) (W)
Vent-a-Light B 110 31 6.5 35 Standard FAN2229