MD 141 30001005123767 c.l e e- ENGLISH Directions or Use ESPANOL Instrucciones de utilizaci6n ITALIANO Instruzioni per l'Uso FRAN<;:AIS Mode d'emploi DEUTSCH Gebrauchsanweisung NEDERLANDS Handleiding NORSK Bruksanvisning SVENSKA Bruksanvisning SUOMI Kayttoohje life Property of: Learning Resources Center Bio-Information Center CREIGHTON UNIVERSITY 28th &Burt Street Omaha. NE 68178 Laerdal wwwl rd I con helping save lives
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MD 141 30001005123767 c.l
e e-
ENGLISH Directions or Use
ESPANOL Instrucciones de utilizaci6n
ITALIANO Instruzioni per l'Uso
FRAN<;:AIS Mode d'emploi
DEUTSCH Gebrauchsanweisung
NEDERLANDS Handleiding
NORSK Bruksanvisning
SVENSKA Bruksanvisning
SUOMI Kayttoohje
life Property of:
Learning Resources Center Bio-Information Center CREIGHTON UNIVERSITY 28th &Burt Street Omaha. NE 68178
~ Laerdal wwwl rd I con helping save lives
I
Little Anne
iltle Anne has been developed to provide a co~i
effective altemative for CPR training orograms.
More ma Ik,ns can be used in the classroom,
cr asing hands-on practice and active participa
tion for the students. All necessary educational
req irements have been maintained to assure
quality training.
Each Litt e Anne model simulates an adult of
average physiology and anatomy and IS designed
for realistic training of b,J>c life support s<;lIs, pri
marily c31-dlopulmonary resuscitation (CPR).
Features included are:
Natural obstruction of the allway
Realistic facial features and a movable jaw
Realistic compliance for venLildlions
and compressions
Chest rise and fall with proper ventilations
Realistic landmarks for compression pOint
location
Audible confirmation of correct compression
depth
C rryi g bag opens into a training mat.
AED Little Anne
The AEO Little Anne was developed to work n
combi ation with the Laerdal or Philips brand
AEO Trainer 2 device as a complete training sys
tem. Laerdal Link Technology in the AEO Little
Anne Traini g System, rec;uires the student to
properly place the training pads on the manikin
chest before the AEO Tra ner 2 wi I proceed
hro h the selected scenario. If pads are
Improperly placed, the AEO Trainer 2 will
respond with the appropriate vOice prompts.This
is accomplished with no visible connectors on
the chest skin The AEO Little Anne also has
LEOs in the chest skin indicating the center of
correct pad placement.The LEDs light up auto
matically when pads are attached correctly. If an
electrode is loose or Incorrectly placed on the
manikin, the AED T,'ainer 2 will repeat the voice
prompt to apply the electrode pads.
Note: For use with the AED Little Anne manikin with
Loerdol Link Technology, electrode training pods with
a white connector must be used (these electrodes
are also marked with the Loerdol Link Technology
logo)
Additional features for AEO Little Anne are:
Sensors n the chest skin cetect proper
pad ? acement
Pad placement feedback provided by LEOs
in the chest skin.
\
I.
Instructions for use
Remove the carrying bag from the plastic bag. Open the bag and lay it flat on the floor
This will now serve as a training mat. Little Anne is delivered fully assembled and ready for use.
Unpacking
Some additional supplies are provided for your
conve ience. Included With your Little Anne /
AED Little Anne manik:in (cat. No. 02 00 20,
02 00 25 or 02 00 50) are:
Little Anne with Compression C1ic<er
I extra Resusci Manikin Face
I extra Little Anne Allway
Carrying BagITraining Mat
Hygiene solution for training manikins
Directions for Use
Jacket (AED Little Anne only)
Using the compression clicker
ittle Anne IS supplied with a compression clicker
th t will confirm correct compression depth.
When the clICker is "on", the student will hear
a "click" when the torso is compressed
I 1/2 inches (38 mm).
Fig I To use the clicker:
The manikin is delivered Fig. 2with the clicker in the "on" (inner) position.
Fig. 2 To disable the clicker:
Pullout the ciJcker lever
Note: Always push the clicker lever co the "On"-posiuon before repackmg the manikin.
Sanitation Sanitation of Manikin Faces, see sepal'ate sheet.
Little Anne Airway
Th Ie Anne Airway is designed for disposal after each class.
Fig 3
GG~ G
~ 0G~
To remove Fig. 3
Ia Detach manikin face at each ear:
2a Lirl manikin face off valve coupling.
3a Remove Jaw from posts in head.
4a Remove valve.
Sa Open chest cove'.
6a Remove used airway and discard.
Fig. 4
G
o
To install Fig. 4
Ib Lay lung flat on torso and attach to hook.
2:J Snap airway valve onto jaw.
3b Reattach jaw to posts In head.
4 Fasten chest cove' onto the fOL.r retainers.
Sb Push face coupling into airway valve.
6:J Fasten face onto retainers at each ear:
I Maintenance Vl ::J C)
Z wGeneral manikin cleaning. Routine disinfection of the entire manikin is not required, but periodic cleaning
of the head, torso, chest skin, and training mat is recommended. These should be washed with a luke
warm soapy solution, and then rinsed with a clean damp cloth. Proper care will maintain the appearance
and general condition of your Little Anne.
To change clicker
Ii fig 6
To remove - FIg. 5
Open the chest cover
Remove the nb plate.
Set the clicker in the "off"
position (outer position).
Press together the sides of the
clicker and lift it up. Push It out
through the opening in the
torso.
(~ To InStall - Fig. 6
Insert the clicker from outside
(with the pad facing upward).
Press the clickel' down until it
snaps into place.
To change clicker activator - Fig. 7
The clicker activator is located underneath the
nb plate. It is fastened by snapping it in place
over the edge and into the two holes of the rib
plate as illustrated.
To change chest skin - Fig. 8
Unhook the chest skin from its retainers.
Note: For the AED Little Anne model be aware of
wires connecting the chest skin to the battery box under the rib plate. Disconnect the two wires from
the battery box (when connecting the new chest
skin wires to the battery box It does not matter which wire goes to which socket).
To change head - Fig. 9
To remove
When 'ace, airway and jaw have been removed
(desCrIbed in "Fig. 3"), flex the lower edges 0' the
head outward until the head can be removed.
To install
Grasp the manikin head wrth both hands, with
your f,ngers on the :nside of the head. Gently pull
outwards and slide the head onto the neck posts,
one side at a time.
To Install the airway. face and jaw, see poge 4.
AED little Anne only
To change battery
AED Little Anne comes with a standard alkaline
6LF22 I 6LR6 I 9 Volt battery.
Open the chest skin.
Note: Be aware of wires connecting the chest
skin to the battery box under the rib plate
Remove the old bactery and install a new
9 Volt alkaline battery. 'de sure to follow the
positive (-'-) and negative (-) batte-y Icons
etched into the inside of the battery holder
when inserting new battery.
6
Fig. 9
Battery low indicators
Depressing the test button on the battery
board will illuminate the LEOs in the chest
skin if battery strength is sufficient for
operation. If the LEOs do not light when the
button is depressed a new oattery is reouired.
A "Battery low" voice prompt from the AED
Trainer 2 will be heard immediately after
connecting Laerdal Link training pads if
the manikin battery is low.
I
- 945090
• UttleAnne.,.."..
Parts
Models 0200; 02 2
L
Parts C20 I,
02 120 02 0 'Xl OL 1005 020 10 0201 i I 0201 12 020200 0202 JI 02 02 ,,2 020610 ,)2 07
litth.. ""1!'ie
LltIle All/l~, wI JZarf..: sk J
D·it1.eAnl'\e
Bad <cP.cton Klb 'ale Che':t over :r~t cover w/darlo: sl<'ln ComF 1':'SS~ ,r; :.pr ing (ornpre)!:,IOn II(ker
C1·ker ac:tr.,Jtvl
Head complete JdN cl'sembll Hf:ad assernD:1 OlfE'ct )!lS (Dr U·'? Carr ylng tag
Accessories 300
'J2 03 01 0203 10 ,203 I 3 0210 3 02 5
54230
15423 1,24 DO
152401
15 L 01
J1JIV.'dI~ c plete. pk.g of 24 A Wo!S <orr.;>le' p.g of 9 V.lve' omplete, pkg. O' 50 f,lt~ & lung pkg, d 100 MJn'"n Faces. pl<g of 6 Mdr ~In For'?',; d¥k <
g 016 Vwkor Rapid Pack ( Ox5 t~1blet and bottle) V1rkOrl ',}LJw't~ IOx5g Resu$(, Manikin Wipes. pig of 50 ResIJ'iC1 Manlkln W,pes. pkg, of 1200 r1an'k n Face 5hleld~.
6 lOPS or 36 ea.
Additional parts for AED Unle Anne only. 02 50 i B.tttery board 0250 15 AED Chest !un 02 50 3 Soh pack AED tue Anne,
Blue OL 50 ;0 Jacket AED Lmle Anne 94 50 9, Tr.",,,ng P.,ds, laerdal Link
fra1rung System
For customers uf PtulipS Medical Systems, please canto your sales representative or CAli I (800) 263 3342 for order'lng InfOI malion.
Product speClkatons are ~bJe<.-1.
to change NMout notice.
; #C€ product tS in compliance WI the PeS:> WI requlren"len i