Top Banner
©Y.Y. Sang May 2007 Hemocontrol Hemocontrol Management of Management of Intradialytic Hypotension Intradialytic Hypotension
33

Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

Jul 29, 2018

Download

Documents

lykiet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

HemocontrolHemocontrol

Management of Management of Intradialytic Hypotension Intradialytic Hypotension

Page 2: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Dialysis ComplicationsDialysis ComplicationsCramps 31%

Hypotension 50%

Vomiting 1%

Headache 18%

Nephrologische Praxen Rostock1998-1999 Dialysis n=6,508

BP = CO X SVR

Page 3: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Potential Causes of HypotensionPotential Causes of Hypotension

• Intravascular volume depletion• Lack of vasoconstriction• Cardiac factors

Page 4: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Prevention of HypotensionPrevention of Hypotension• No BP medication pre dialysis• Profile ultrafiltration• Profile sodium• Evaluation of dry weight• Isolated or sequential ultrafiltration• Blood volume monitoring – critical value• Volume expanders – albumin

Page 5: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Treatment of HypotensionTreatment of Hypotension• Decrease the UF rate • Decrease the total weight loss• Extend the treatment • Cooler dialysis• Medication: Amatine• Volume expanders: Albumin

Page 6: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Unconventional OptionsUnconventional Options

• Daily dialysis• Physio Dialysis: Hemocontrol• Convective therapy: Hemofiltration

Hemodiafiltration

Page 7: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Why Why PhysioPhysio Biofeedback?Biofeedback?• Non invasive

• More physiological - Biofeedback

• No added cost

• Easy to use: intuitive

Page 8: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

What Is Biofeedback?What Is Biofeedback?Hemocontrol (Gambro)

Blood Volume

Controls UFR Controls Sodium

Page 9: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

What Is The Difference?What Is The Difference?Technical Prescription

Dialysis prescription is determined and entered into the machine based on the patient’s previous dialysis treatment.

The UFR and CD are not profiled or profiled.

Profiles are limited by the time intervals

Clinical Prescription

Dialysis UF and CD is controlled every few minutes by the limits and targets programmed into the controller (Integra).

The limits and targets (UF, BV, CD, BV/TWL ratio) are calculated using the averages of 8 to 10 treatments.

Page 10: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

The Open Loop Concept In HDThe Open Loop Concept In HDOpen-Loop Block Diagram

Technicalprescription

StandardDialysisMachine

Patient

UFRDC

This is similar to a pilot flying at night without radar assistance. Route, weather conditions ?

The situation is exactly the same for dialysis patients. The nurses know the patients very well but some of the pt’s symptoms may force them to deviate from the prescribed prescription.

®

Page 11: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

The Biofeedback ConceptThe Biofeedback ConceptClosed-Loop Block Diagram

The PHYSIO biofeedback system now provides radar-like information. It will continuously inform the nurse about the pt’s current situation, compare it to the set target and, if necessary, adjust the parameters.

Clinicalprescription Dialysis

MachinePatientController

Monitoring

TWLBVNa

®

Page 12: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Physiological controller for 3 Physiological controller for 3 different goals.different goals.

DialysisMachine

Physiologicalcontroller

actual DC

actual WLR

actual BV

BV target

DCeq target

TWL targetWLR

DC

®

Page 13: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Goals of Hemocontrol ™Goals of Hemocontrol Goals of Hemocontrol ™™

Dialysate conductivity

Blood volume

Total weight loss

⇒ Blood pressure stability

⇒ Achievement of thetarget weight

⇒ Prevention of asodium overload

Page 14: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Ideal curve varies with TWLIdeal curve varies with TWL

0 60 120 180 240-14

-12

-10

-8

-6

-4

-2

0

Time (minutes)

BV

vera

nder

ing

(%)

Total weight loss4 kg

0 60 120 180 240-14

-12

-10

-8

-6

-4

-2

0

Time (minutes)

BV

vera

nder

ing

(%)

Total weight loss3 kg

0 60 120 180 240-14

-12

-10

-8

-6

-4

-2

0

Time (minutes)

Cha

nge

in b

lood

pre

ssur

e (%

)

Total weight loss2 kg

Page 15: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Patient SelectionPatient Selection• Hemodynamically unstable: hypotension

or cardiac failure• Over hydration• Diabetic • Frequent cramps• Hypertension

Page 16: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Pre Assessment MonitoringPre Assessment Monitoring

Monitor BV and TWL for 6 to 10 treatments and calculate the

TWL/BV ratio

Assessment form

Page 17: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

HC ParametersHC Parameters• Targets: clinical prescription

• Tolerances

• Limits

Page 18: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

1st Step: Targets1st Step: Targets• *TWL ( varies each treatment)• Final CD• Final BV: determined by pre-assessment

period , where the mean ratio for BV/TWL is calculated. When the *TWL is entered into the dialysis machine, the final BV is displayed.

Page 19: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

2nd Step: Prescription Limits2nd Step: Prescription LimitsSafety limits defined by the nurse

• Sodium limits: maximum and minimum based on the final CD

• Maximum UFR

Page 20: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

3rd Step: Set Tolerances3rd Step: Set Tolerances• Total weight to be removed: +/- 300 gms• BV: +/- 3%• CD: +/- 3mS/cm

Tolerances

Page 21: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Target & TolerancesTarget & Tolerances

Ideal curve

TargetTolerance

Page 22: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

1 32 4-9

-8

-7

-6

-5

-4

-3

-2

-1 standard haemodialysis

9 weeks Hemocontrol

Cha

nge

in b

lood

vol

ume

in(%

)

Duration of dialysis (hours)

The blood volume decreases more sharply during the first hour with Hemocontrol than during standard haemodialysis. While the blood volume in the second half of the dialysis is relatively stable.

Standard HD vs. HemocontrolStandard HD vs. Hemocontrol

Page 23: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Standard HDStandard HD

Page 24: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

HemocontrolHemocontrol

Page 25: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

AdvantagesAdvantages• Reduction of intradialytic morbid events• Improved well being post dialysis• Dialysis efficacy• Dry weight adjustment• Better control of hypertension

Page 26: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

StatisticsStatisticsScarborough Hospital 30Toronto East General 10Alliston 20Collingwood 3North Bay 30Thunder Bay 30Renfrew 30Huntsville 6London 10

169

Page 27: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

How does HC affect you?How does HC affect you?

Education

• Theoretical background• How to manage alarms • Decrease in intradialytic complications• Less need for nursing intervention• Re-assessment of patient: q3month

Page 28: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

How does HC affect the patient?How does HC affect the patient?

• Inform the patient

• Changes in dry weight

• Monitor their sense of well being

• Decrease in BP stabilizing meds

Page 29: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

HemocontrolHemocontrol• Improves the well being of the patient• Makes daily routine interesting• Decrease in nursing interventions• Free time for better care and

communication with patient

Page 30: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Page 31: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

Product info 2.1. 31

Assessment Assessment Assessment

Return

Page 32: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Safety parameters : Limits

WLR DC

Max Initial WLR

TWL / Time

Max DC

Min WLR

Min DC

Cond. max. = (Final Cond.) + 1.5 mS/cmCond. min. = (Final Cond.) – 0.5 mS/cm

Cond. max. = (Final Cond.) + 1.5 mS/cmCond. min. = (Final Cond.) – 0.5 mS/cm

WLR max. = average WLR x 1.8WLR max. = average WLR x 1.8

Return

LimitsLimits

Page 33: Management of Intradialytic Hypotension · • Profile sodium • Evaluation of dry weight • Isolated or sequential ultrafiltration • Blood volume monitoring – critical value

©Y.Y. Sang May 2007

Preset Machine TolerancesPreset Machine Preset Machine TolerancesTolerances

BVerror

WLerror[Na]error

Tolerance BV: ± 3 %Tolerance TWL: ± 300 gr.Tolerance Cond. (Na): ± 0,3 mS/cm

Tolerance BV: ± 3 %Tolerance TWL: ± 300 gr.Tolerance Cond. (Na): ± 0,3 mS/cm

Return