Top Banner

of 89

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 1 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Maintenance Instructions

    Az S 350 U

    Microcomputer Axle Counting System

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 2 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Confidentiality: None

    Issuing department: TS RA SD 73

    Author of German document

    Springorum TS RA SD 73, 3063

    Translation released by

    Argiel TS RA SD 75, 3136

    2004-05-10 sgd. Argiel

    Translation checked by

    Mller TS RA SD 75, 3219

    2004-05-07 sgd. Mller

    Translation prepared by

    Argiel TS RA SD 75, 3136

    2004-05-05 sgd. Argiel

    Name Org. unit, tel. Date Signature

    For the original signatures, see the Verification Record with the document number M01100291109, Revision A.

    NOTE The contents of this translation correspond to the German document with the Siemens code number A25552-C605-U1-3-20. The German document was assessed and released (EBA stamp) by the German Federal Railways Office.

    Change List

    Revision, sequence

    Code no. level

    Date of issue

    Author Sections changed

    Reason, Change Notice if applicable

    C, 4 3 2004-02-06 Springorum All Revision

    Change documentation for revision C/code no. level 3

    Review participants See Review Minutes; M0110237573, A

    Section Changes/measures

    All See Review Minutes; M0110237573, A

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 3 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Contents

    1 How to Use this Manual ...................................................................................................... 5 1.1 Scope and Purpose of this Document................................................................................... 5 1.2 Instructions ............................................................................................................................ 5 1.3 Pictograms Used ................................................................................................................... 6 1.4 Qualified Staff ........................................................................................................................ 7 1.5 Suggestions........................................................................................................................... 8

    2 Safety Regulations .............................................................................................................. 9 2.1 Basic Safety Regulations....................................................................................................... 9 2.2 Handling of Circuit Boards................................................................................................... 11

    3 Structure and Mode of Operation .................................................................................... 13 3.1 Structure .............................................................................................................................. 13 3.2 VAU Board........................................................................................................................... 15 3.3 STEU Board ........................................................................................................................ 17 3.3.1 Normal Display .................................................................................................................... 17 3.3.2 Statistics Display/Diagnostics.............................................................................................. 21 3.3.3 Display after Emergency Shutdown .................................................................................... 21 3.4 BLEA12 Board..................................................................................................................... 22 3.5 SIRIUS2 Board .................................................................................................................... 26 3.6 VESBA Board ...................................................................................................................... 27 3.7 DIGIDO Board ..................................................................................................................... 29 3.8 SVK2150 Power Supply Board ........................................................................................... 30

    4 Diagnostics ........................................................................................................................ 32 4.1 Fault Indication .................................................................................................................... 32 4.2 Troubleshooting (Indoor Equipment)................................................................................... 32 4.3 Statistics Functions/Diagnostics.......................................................................................... 33 4.3.1 Selection.............................................................................................................................. 34 4.3.2 LED Display Tables for Selection Options .......................................................................... 37 4.3.3 Examples of Option Selection ............................................................................................. 47 4.4 Evaluation Computer Fault Types ....................................................................................... 51 4.4.1 Failure of an Evaluation Computer Board ........................................................................... 51 4.4.2 Emergency Shutdown ......................................................................................................... 52 4.4.3 Technical Requirements for Successful AzGrT or vAzGrT Operation ................................ 58 4.4.4 AzGrT Button Operation Error ............................................................................................. 59 4.4.5 Cancelling a Reset Restriction ............................................................................................ 59

    5 Corrective Maintenance.................................................................................................... 60 5.1 Switching the Evaluation Computer On and Off.................................................................. 60 5.1.1 Switching On ....................................................................................................................... 60 5.1.2 Switching Off ....................................................................................................................... 63 5.2 Troubleshooting (Indoor Equipment)................................................................................... 63 5.3 Replacing Boards ................................................................................................................ 64 5.3.1 Removing Boards ................................................................................................................ 64 5.3.1.1 Inserting Boards ...................................................................................................................65

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 4 of 89 Copyright Siemens AG 2001 All Rights Reserved

    5.3.1.2 Spare Boards........................................................................................................................65 5.3.1.3 Marking Boards ....................................................................................................................66 5.4 Special Board Replacement Conditions.............................................................................. 67 5.4.1 Special Conditions for VAU Board ...................................................................................... 67 5.4.2 Special Conditions for BLEA12 Board................................................................................. 68 5.4.2.1 Slot Assignment for VAU Program Revision Level

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 5 of 89 Copyright Siemens AG 2001 All Rights Reserved

    1 How to Use this Manual

    1.1 Scope and Purpose of this Document

    These Maintenance Instructions explain the preventive and corrective maintenance of the new Az S 350 U Axle Counting System from Siemens. Throughout this document, the axle counting system will be referred to under its short designation Az S 350 U.

    The Az S 350 U is operated as a fail-safe computer in a 2-out-of-2 configuration on the basis of the proven SIMIS Fail-safe Microcomputer System from Siemens.

    It provides a universal interface for connecting it to any interlocking system. The interface is a parallel interface using floating relay contact outputs and optocoupler inputs.

    1.2 Instructions

    This document contains instructions and information on inspection, preventive and corrective maintenance.

    The system structure and functions are only described to the extent necessary for preventive and corrective maintenance.

    For additional information on the axle counting system, please refer to the Az S 350 U System Description, English version (A25552-C605-U1-*-7629).

    Note: Throughout this document, instructions are marked by an arrow symbol.

    Example:

    Set the switches of the power supply boards to "I".

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 6 of 89 Copyright Siemens AG 2001 All Rights Reserved

    1.3 Pictograms Used

    The safety information in this document is given to ensure your personal safety and to prevent the system described or components connected from being damaged.

    In this document, safety notices and warnings are marked by the following pictograms plus an explanatory text. These pictograms refer to the present documentation as well as to the products themselves and have the following meaning:

    DANGER This pictogram, the signal word "Danger" and the associated text point to dangers which may cause death or personal injury.

    S

    SAFETY REQUIREMENT This pictogram, the signal word "Safety Requirement" and the associated text point to requirements resulting from the safety case. They must be observed under any circumstances.

    CAUTION This pictogram, the signal word "Caution" and the associated text point to dangers which may cause destruction of or damage to components, circuit boards or assemblies.

    NOTE This pictogram, the signal word "Note" and the associated text give further details and additional information.

    WARNING This pictogram, the signal word "Warning" and the associated text point to "electrostatic sensitive devices". Before touching components marked in this way, always carry out charge equalisation.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 7 of 89 Copyright Siemens AG 2001 All Rights Reserved

    1.4 Qualified Staff

    Maintenance work on the Az S 350 U may only be carried out by specially trained staff authorised by the railway operator in question.

    Any work which could impair the safety of persons or operation of the Az S 350 U must not be carried out.

    S

    SAFETY REQUIREMENT Work on the Az S 350 U (including ZP 43 E/V) may only be carried out with the approval of the signaller or an authorised person responsible for the track vacancy detection section concerned.

    DANGER Do not carry out any unauthorised modifications to the Az S 350 U.

    The maintenance personnel must apply the prescribed safety measures for working in the vicinity of live parts according to VDE 0105, Part 1: Operation of Electrical Installations (only valid in conjunction with VDE 0105, Part 2).

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 8 of 89 Copyright Siemens AG 2001 All Rights Reserved

    1.5 Suggestions

    Do you have any tips, ideas or suggestions concerning these Maintenance Instructions?

    Perhaps you have spotted an error or know how to optimise a procedure?

    Please contact us directly. Your ideas and suggestions will be gratefully received.

    Address:

    Siemens AG TS RA SD 7 Documentation and Translation

    P.O. Box 3327 D-38023 Braunschweig Germany

    Tel: +49 (0) 531 2 26-30 63 Mr. Springorum

    Fax: +49 (0) 531 2 26-41 35

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 9 of 89 Copyright Siemens AG 2001 All Rights Reserved

    2 Safety Regulations This section lists the safety regulations to be observed for diagnosis, corrective maintenance, inspection and preventive maintenance of the Az S 350 U.

    2.1 Basic Safety Regulations

    In order to avoid personnel injuries and damage to equipment, the following safety regulations must be carefully observed. The personnel must be familiar with these Maintenance Instructions in order to ensure accident-free and correct working.

    DANGER When doing work on the Az S 350 U, the applicable regulations of the railway operator as well as the valid statutory provisions on health and safety at work must be observed! Work on the system may only be carried out by qualified staff!

    DANGER Unauthorised changes to the cabling and the stored programs and data will cause invalidity of the safety case. Safety cannot be ensured any longer.

    DANGER All parts such as counting heads, etc. must not exceed the maximum admissible interference voltage (transient interference of max. 1.5 kVrms / continuous interference of max. 250 Vrms according to the valid railway operator regulations).

    DANGER Carry out inspection and corrective maintenance work during intervals between trains only.

    NOTE Keep a fault record when doing corrective maintenance work.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 10 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Before starting work on the track, carry out the safety measures in accordance with the relevant railway regulations.

    Maintenance work may only be carried out using the approved tools, devices, testing equipment and materials.

    After completion of preventive or corrective maintenance work on ZP 43 E/V wheel detection equipment, the following are necessary:

    After preventive maintenance work on an operational system under the following conditions: The associated track vacancy detection section (TVDS) had worked

    correctly before the work began and was indicated as being clear. No trains entered the TVDS during work.

    Check the equipment of the TVDS for correct operation. For this purpose you can simulate a local train movement.

    After corrective maintenance work on a faulty system: The system has to be put back into operation in line with the valid safety regulations of the railway operator and the approval authority. Example: The signaller or authorised person must first check the operating

    department regulations and cancel the reset restriction (RR) with the AzGrH auxiliary axle count reset button and then actuate the AzGrT or vAzGrT button.

    Then wait for the result of the necessary proceed-on-order runs. The proceed-on-order runs must go across all associated counting heads. They are to check the switching capability of the channels.

    NOTE After having carried out corrective maintenance work on circuit boards, no proceed-on-order runs are required from the manufacturer's point of view.

    NOTE When fuses are replaced, the new fuses must have the same electrical values as the ones replaced.

    After completion of work on Az S 350 U equipment, make sure that the evaluation computer (EC) is functioning correctly. For this purpose, wait until the next train has passed.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 11 of 89 Copyright Siemens AG 2001 All Rights Reserved

    2.2 Handling of Circuit Boards

    S

    SAFETY REQUIREMENT Only remove or insert boards when the computer is disconnected from power. Removing and inserting boards in the energised state may damage or destroy circuit boards or computer. Do not commission condensed circuit boards.

    CAUTION All boards marked with the symbol for electrostatic sensitive devices must be handled with special care.

    WARNING Symbol "Electrostatic sensitive device" Before touching components marked in this way, always carry out charge equalisation in order to prevent discharge via the electronic circuits.

    CAUTION Do not touch board connections, conductors, components or plug connectors.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 12 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Please observe the following when handling circuit boards:

    Only place boards on high-impedance bases which are conductive or have been made conductive (e.g. for example carbonised foam mats).

    Before picking up or placing a board, carry out charge equalisation by touching the base.

    Before removing a board from or inserting a board in a device, frame, cabinet or rack, carry out charge equalisation by touching an uncoated metal part of the device, frame, cabinet or rack.

    Do only touch the edges or front panels of boards. Remove boards by their handles only. Uninstalled boards must be stored and transported in the packaging at all

    times. If boards are to be handed over from one person to another without their

    packaging, carry out charge equalisation by touching the hands of the person concerned before handing over.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 13 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3 Structure and Mode of Operation The Az S 350 U consists of two main components:

    outdoor equipment indoor equipment

    The outdoor equipment comprises a number of ZP 43 counting heads, in variant E (cast aluminium housing) or variant V (plastic housing), with track vacancy detection sections assigned to them. External wiring also belongs to the outdoor equipment. The indoor equipment consists of the evaluation computer (EC).

    These Maintenance Instructions refer to the Az S 350 U as well as the setting of the counting heads via the EC. Corrective maintenance of the counting heads is described in the Operating and Service Manuals for ZP 43 E (A25063-B217-H21-*-76N9), ZP 43 E for Use at DB AG (A25063-B218-H21-*-N9, available in German only) and ZP 43 V (A25063-B216-H21-*-76N9).

    3.1 Structure

    Figure 1 Front view of Az S 350 U evaluation computer (including slot numbers)

    The plug-in boards are accommodated in a single-tier mounting frame with wiring backplane. Dummy boards are inserted into the slots intended for optional boards.

    The SIRIUS2 board (serial computer interface universal board) enables the communication between the evaluation computers connected. It provides two serial, bidirectional interfaces for data transmission, each of them being equipped with a V.24 output. The SIRIUS2 board is used in one channel only.

    All inputs and outputs (CI, CI, AzGrT or vAzGrT, RR, RA, user-defined block information) to or from the interlocking are done via the BLEA12 block

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 14 of 89 Copyright Siemens AG 2001 All Rights Reserved

    input/output board. Two BLEA12 boards (first pair of BLEA12 boards) are required for the dual-channel Az S 350 U, one for channel 1 and one for channel 2. A second, optional pair of BLEA12 boards can be inserted. Each computer channel has a STEU control and diagnostic board, which evaluates the WDE signals received (counting head- and section-specific data). The VAU processing and monitoring board, a CPU board, is the fail-safe microcomputer (SIMIS C hardware core) of the Az S 350 U. The VAU board provides monitoring and comparator functions for synchronised dual-channel microcomputer operation. One VESBA amplifier, trigger and band-pass filter board is required per directly connected counting head. It provides electrical isolation between indoor and outdoor equipment (counting head). The VESBA board splits the signal frequencies f1 and f2 into two independent channels and filters, amplifies, rectifies and evaluates (trigger) the data transmitted from the counting head. Each counting head (CH) has its own VESBA board (CH 1 to CH 5). The DIGIDO digital double-usage board is used if WDE information is to be jointly used by an Az S (M) 350, version B/M, and an Az S 350 U (digital double usage of a counting head via DIGIDO). The SVK2150 power supply board provides 5 V for the evaluation computer and 70 V for the counting heads.

    Quantity Short designation of board

    Description Order no.

    1 MF Mounting frame S25552-C605-U1

    2 VAU* Processing and monitoring board S25552-B600-U1

    2 STEU* Control and diagnostics board S25552-B601-B1

    2 or 4 BLEA12* Block input/output board S25552-B603-D1

    0 or 1 SIRIUS2 Serial computer interface universal board S25395-B171-A3

    0 to 5 VESBA Amplifier, trigger and band-pass filter board S25552-B604-C1

    0 or 1 DIGIDO Digital double-usage board S25552-B699-U1

    1 SVK2150 Power supply board S25552-B651-C1

    * Make up the hardware core: channel 1 or channel 2 standard configuration: at least one BLEA12 board per channel

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 15 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.2 VAU Board

    Processing and monitoring board S25552-B600-U1

    VGL = Comparator (yellow LED)

    SPW = Voltage controller (red LED)

    PAB = Program-controlled shutdown (red LED)

    ANL = Start-up (red LED)

    Red button = System reset

    VGL

    SPWPABANL

    Figure 2 Front view of VAU board

    Equipped with 2 MHz 8085 microprocessors, the two VAU boards make up the core of the microcomputer system. They have 8 kB RAM and 32 kB EPROM. Due to the dual-channel layout of the evaluation computer, there is one VAU board per channel.

    The VAU board is a SIMIS C CPU board, in which two independent MES80 microcomputers are connected without additional circuits to form a clock-synchronised dual-channel microcomputer system providing SIMIS core functions.

    Each VAU board monitors and compares the synchronous and identical operation of both microcomputers and, in case of a fault, transmits a switch-off control signal (SCS) in order to disconnect the signalling and safety peripherals connected.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 16 of 89 Copyright Siemens AG 2001 All Rights Reserved

    After a system reset, the standard sequence of operations starts on the VAU boards. In order to make both channels start synchronously, both reset buttons on the front panels of the boards must be pressed simultaneously for approx. 1 second.

    The SIMIS online test program (SOPP) is started after initialisation. The complete, interruptible program run takes approx. 4 minutes. The SOPP program is a low-priority program executed in the background and is always quit after an interrupt request.

    If both LEDs "VGL" on the VAU boards light up, the evaluation computer is operational. Both synchronously working microcomputers process identical data.

    A lit LED "SPW" indicates that the operating voltage is above or below the permissible value of 5 V DC. The system has to be restarted.

    A lit LED "PAB" indicates a program-controlled emergency shutdown, i.e. if the comparator has detected asynchronism in the operating system or if, during the continuous test cycles, a safety-related fault has been detected. This initiates a hardware- or software-controlled shutdown and the evaluation computer switches to the occupied state. The system then has to be restarted. The causes of faults can be identified via the LEDs (LED 0 flashing permanently) on the STEU board (see Section 4.4.2 "Emergency Shutdown", page 52).

    During evaluation computer start-up, the LED "ANL" lights up for approx. 3 s.

    For a synchronous start of the evaluation computer, after a failure, both VAU boards have a system reset button. Pressing both red buttons simultaneously for approx. 1 s will restart the evaluation computer.

    Front panel coding 1727 according to C25117-A55-A1-*-18

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 17 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.3 STEU Board

    Control and diagnostic board S25552-B601-B1

    The control and diagnostic board buffers the signals transmitted by the counting heads. Due to the dual-channel layout of the evaluation computer, there is one STEU board per channel. The LEDs on this board display the following:

    normal display: display of operating states of the four track vacancy detection sections (TVDS) (during operation; operating state display)

    statistics display (diagnostics): display of operating states for a certain counting head or track vacancy detection section (switchover/selection via AzGrH button)

    display after emergency shutdown: display of operating states in case of emergency shutdown

    Front panel coding 897 according to C25117-A55-A1-*-18

    3.3.1 Normal Display

    Lit LEDs

    2 xx

    0123456789

    1011

    Diagn.

    0 - System reset performed, pressing of AzGrT required1 - Minus axle blocking effective; counting capacity exceeded; undefined couting pulse2 - Count monitoring3 - Faulty telegram transmission between evaluation computers or the second evaluation computer is shut down4 - Reset restriction (RR) effective5 - Section occupied, axle count not equal to 0 or another LED is on

    6 - As for LEDs 0 to 5 of TVDS 1 7 - "8 - " 9 - " 10 - " 11 - "

    2 xx

    0123456789

    1011

    Diagn.

    Display TVDS 1

    Display TVDS 3

    STEU 1Channel 1(left board)

    2 xx

    0123456789

    1011

    Diagn.

    Display TVDS 2

    DisplayTVDS 4

    STEU 2Channel 2

    (right board)

    TVDS 4 not configuredDisplay of

    telegram transmission state

    Mea

    ning

    of L

    EDs

    for T

    VDS

    1 M

    eani

    ng o

    f LED

    s fo

    r TVD

    S 3

    Lit LEDs

    0 - As for LEDs 0 to 5 of TVDS 1 1 - "2 - " 3 - " 4 - " 5 - "

    6 - As for LEDs 0 to 5 of TVDS 1 7 - "8 - " 9 - " 10 - " 11 - "

    Mea

    ning

    of L

    EDs

    for T

    VDS

    2M

    eani

    ng o

    f LED

    s fo

    r TVD

    S 4

    TVDS 4 not configured7 - LED 7 to 9:8 - Display of telegram9- transmission state

    Figure 3 Front view of STEU board; display of operating states for TVDS 1 to 4

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 18 of 89 Copyright Siemens AG 2001 All Rights Reserved

    NOTE The meaning of LED 4 (reset restriction) is only applicable to the AzGrT mode. In the vAzGrT mode LED 4 is permanently off.

    Meaning of LEDs on the STEU board (normal display)

    LED display

    ! = steady l.

    = flashing

    Meaning Cause Effect Remedy

    LED 0 = !

    System reset Hardware reset: Reset buttons on VAU boards have been pressed

    Power supply switched on

    EC in permanently occupied state

    Obtain track clear indication via visual inspection

    Press AzGrT button after reset

    LED 0 = Program-controlled emergency shutdown

    EC fault resulting in asynchronous operation of the two channels

    AzGrT button has been pressed on one or both channels during hardware reset

    Asynchronism of block information

    For further possible causes see Section 4.4.2 "Emergency Shutdown", page 52

    Program-controlled shutdown of EC results in permanently occupied state

    Program is caught in an endless loop

    On both VAU boards, the LEDs "VGL" are switched off and the LEDs "PAB" are switched on

    Remove cause of fault

    Carry out hardware reset

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

    Minus axle blocking effective

    At least one axle more counted out than has been counted in

    Permanently occupied state caused by minus axle blocking

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

    Counting capacity exceeded (max. 32,767 axles)

    Incorrect programming of counting direction of a counting head

    Counting head counting out is faulty

    Counting head maladjusted

    Permanently occupied state

    Remove cause of fault

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

    LED 1 = !

    Undefined counted pulse

    Inexplicable pulse detection by counting head

    Permanently occupied state

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 19 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Meaning of LEDs on the STEU board (normal display)

    LED display

    ! = steady l.

    = flashing

    Meaning Cause Effect Remedy

    Count monitoring double wheel detector traversed on one channel only (e.g. shunting movement)

    Permanently occupied state without counting

    Occupied state and display are maintained until next complete traversal of double wheel detector or next AzGrT operation

    LED 2 = !

    Count monitoring counting head fault due to spurious pulse

    Double wheel detector, after complete traversal, detected pulses on one channel only (more than 4 ms)

    Double wheel detector, during a traversal, detected pulses due to spurious pulse (more than 4 ms)

    Double wheel detector, without a traversal, detected pulses due to spurious pulse (more than 4 ms)

    Counting error leading to a permanently occupied state

    No counting error; if at least one axle follows after the cause, the track clear indication will be given after the train has passed, display is switched off

    Occupied state without a train; occupied state and display are maintained until next traversal with track clear indication or until next AzGrT operation

    Check counting head concerned including cable

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

    LED 3 = ! Telegram transmission faulty or switched off

    Data transmission between ECs is faulty

    Second EC has been switched off

    Second EC is in emergency shutdown state

    Data transmission between ECs was faulty (DIP switch TELFM is set to Off and double wheel detector detected no pulses)

    As long as the connection is interrupted or faulty data is received, the TVDS with remote counting heads remain in the occupied state

    Occupied state and display are maintained until next complete traversal of double wheel detector or next AzGrT operation (DIP switch TELFM set to Off)

    Check connection between the ECs

    Check whether second EC has been switched off or is in an emergency shutdown state (restart)

    Reset EC by pressing the AzGrT button

    Wait for train run; if TVDS remain occupied, perform the measures above

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 20 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Meaning of LEDs on the STEU board (normal display)

    LED display

    ! = steady l.

    = flashing

    Meaning Cause Effect Remedy

    Reset restriction (RR) One counting head of the TVDS detected pulses

    There are axles in the TVDS

    Time frame for simultaneous AzGrT operation exceeded (single-channel operation)

    RR effective and section is occupied

    Cancel RR via AzGrH button after section clear proving (according to railway operator regulations)

    If time frame was exceeded, restart EC (after consultation with signaller)

    LED 4 = !

    Reset restriction (RR) Issue of track clear indication for TVDS via AzGrT operation

    RR effective and the section is clear

    Section occupied There is a train in the section which has not yet been counted out (axle count 0)

    Obtain track clear indication via visual inspection

    Reset EC by pressing the AzGrT button

    LED 5 = !

    Section remains occupied

    Axle count 0 e.g. due to counting error

    Reset EC by pressing the AzGrT button

    LED 6 = ! to LED 11= !

    Meaning as for LED 0 to LED 5

    See above See above See above

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 21 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Meaning of LEDs on the STEU 2 board, slot 57, if TVDS 4 is not configured (normal display)

    LED display

    ! = steady l.

    = flashing

    Meaning Cause Effect Remedy

    LED 7 = !

    Telegram transmission via interface 1 is faulty

    Cause as for LED 9, relating to interface 1

    Effect as for LED 9, relating to interface 1

    Remedy as for LED 9, relating to interface 1

    LED 8 = !

    Telegram transmission via interface 2 is faulty

    Cause as for LED 9, relating to interface 2

    Effect as for LED 9, relating to interface 2

    Remedy as for LED 9, relating to interface 2

    LED 9 = !

    Telegram transmission is faulty

    General: Data transmission between ECs is faulty

    Second EC has been switched off

    Second EC is in emergency shutdown state

    Data transmission between ECs was faulty (DIP switch TELFM is set to Off and double wheel detector detected no pulses)

    As long as the connection is interrupted or faulty data is received, the TVDS with remote counting heads remain in the occupied state

    Occupied state and display are maintained until next complete traversal of double wheel detector or next AzGrT operation (DIP switch TELFM set to Off)

    Only necessary if a TVDS is affected:

    Check connection between the ECs

    Check whether second EC has been switched off or is in an emergency shutdown state (restart)

    Reset EC by pressing the AzGrT button

    Wait for train run; if TVDS remains occupied, perform the measures above

    3.3.2 Statistics Display/Diagnostics

    NOTE Display and selection are described in Section 4.3 "Statistics Functions/Diagnostics", page 33, as a part of diagnostics.

    3.3.3 Display after Emergency Shutdown

    NOTE The display is described in Section 4.4.2 "Emergency Shutdown", page 52, as a part of diagnostics.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 22 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.4 BLEA12 Board

    Block input/output board with 12 relay outputs S25552-B603-D1

    T1

    T2

    T3

    T4

    Figure 4 Front view of BLEA12 board (left), front connector with buttons (right)

    The BLEA12 board is the input/output interface of the AZ S 350 U. It has 12 floating relay outputs and 12 floating optocoupler inputs. Inputs and outputs are made via a 48-pin connector on the front panel of the board.

    The BLEA12 is a single-channel board. This is why the dual-channel Az S 350 U system uses two boards of this type, one in channel 1 and one in channel 2 (first pair of BLEA12 boards). A maximum of four track clear/occupied indications with the associated reset restriction (RR) and reset acknowledgement (RA) can be output. The remaining inputs and outputs can be used for freely configurable, operator-specific information (e.g. block information). If the outputs are not required for track vacancy detection, a maximum of 12 freely configurable, operator-specific items of information can be implemented.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 23 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Optional front connectors with four buttons (T1 to T4) on the first pair of BLEA12 boards implement the auxiliary axle count reset button (AzGrH). By a dual-channel operation of the buttons, the reset restriction can be cancelled for each track vacancy detection section. By pressing only one of the two AzGrH buttons (single-channel operation for a configured track vacancy detection section), the normal display of the STEU boards is switched over to statistics display/ diagnostics.

    An optional pair of BLEA 12 boards (second pair of BLEA12 boards) can be inserted for additional functions. If the outputs are not required for track vacancy detection, a maximum of 24 freely configurable, operator-specific items of information can be implemented.

    The operator-specific input data is read in via floating optocouplers inputs under conditions of electrical isolation. The input optocoupler circuit is designed to permit input voltages from 21.6 V to 72 V DC. The operator-specific output data is output via two floating relay contacts.

    The BLEA12 board has a MES80 bus port, which is used for exchange of data with the VAU board. The BLEA12 board also provides the port for the SCSI internal switch-off control signal, which can be used to switch off the power supply of the output relays.

    The BLEA12 board executes the following functions:

    output of track clear/occupied indication (CI and CI) of up to four TVDS output of reset restriction (RR) of evaluation computer for each TVDS output of reset acknowledgement (RA) on successful axle count reset for each

    TVDS input of immediate or preparatory axle count reset (by actuating the AzGrT or

    vAzGrT button) for each TVDS of the evaluation computer input of cancellation of reset restriction (RR) by actuating the AzGrH button for

    each TVDS via optional front connector configuring by means of 96 DIP switches block inputs/outputs for freely configurable, operator-specific information

    The output of a track clear indication (CI) or an inverted signal (track occupied indication, CI) is issued for each track vacancy detection section via floating relay contacts. The BLEA12 board can output indications for up to four TVDS (equivalent or non-equivalent).

    The relay output system for the output of the track clear/occupied indications is of dual-channel design, i.e. the output data is generated and output on each of the two computer channels. To this end, each computer channel has two relays. The

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 24 of 89 Copyright Siemens AG 2001 All Rights Reserved

    relay contacts are linked to form two contact chains (one normally-open contact chain and one normally-closed contact chain or two normally-open contact chains). The outputs have to be linked and evaluated by the higher-level interlocking system, i.e. they have to be checked as to their equivalence or non-equivalence, depending on the configuration.

    Non-equivalent output

    Equivalent output

    Channel 1 Channel 2

    C1 C2 C3

    C4

    C1 C2 C3 C4

    Channel 1 Channel 2

    Figure 5 Output variants

    Thus, in the dual-channel Az S 350 U, four relays contribute to each fail-safe output (track clear/occupied indications and freely configurable, operator-specific information). It can be assumed as being fairly unlikely that these four relays will ever fail in a way that leads to a dangerous failure.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 25 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Indications: clear/occupied e.g. relay circuit

    BLEA12 board

    Interlocking

    V = 60 V DC

    0 V

    Az S 350 U

    V Cha

    nnel

    2 C

    hann

    el 1

    Figure 6 Example of a relay circuit with double-cut

    Depending on the program revision level of the VAU board, the slot assignment of the BLEA12 boards may differ (see Section 5.4.2 "Special Conditions for BLEA12 Board").

    Front panel coding no.: 17 04 according to C25117-A55-A1-*-18

    Front connector coding: application-related

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 26 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.5 SIRIUS2 Board

    Serial computer interface universal board S25395-B171-A3

    Figure 7 Front view of SIRIUS2 board

    For controlling the transmission system (data transmission between evaluation computers), the Az S 350 U has a SIRIUS2 board.

    The SIRIUS2 board provides two serial, bidirectional interfaces for data transmission, each of them being equipped with a V.24 output. One of these V.24 interfaces has two control signals (RTS1 and CTS1).

    The SIRIUS2 board contributes to fail-safety by providing reliable electrical isolation between peripherals and hardware core. For the transmission of fail-safe data, the procedure-protected data transmission procedure FASIT (fail-safe, single-channel transmission of status information) is used.

    On the front panel, there is a 48-pin connector providing the connection for all interface signals.

    Front panel coding no.: 14 56 according to C25117-A55-A1-*-18 Front connector coding no.: 1 04 according to C2311-A55-A35-*-18

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 27 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.6 VESBA Board

    Amplifier, trigger and band-pass filter board S25395-B604-C1

    System 1

    LED (yellow) lights up if system 1 of double wheel detector is being traversed or occupied (or V1 < 1.3 V DC)Potentiometer for voltage adjustment V1 = 3.0 V DC 0.10 VMeasuring socket for signal frequency f1 = 3.60 kHz 0.05 kHz (frequency adjusted at CH)Measuring socket for voltage V1 = 3.0 V DC 0.10 V 0 V measuring sockets for both systems

    System 2

    Measuring socket for signal frequency f2 = 6.52 kHz 0.10 kHz (frequency adjusted at CH)Measuring socket for voltage V2 = 3.0 V DC 0.10 VLED (yellow) lights up if system 2 of double wheel detector is being traversed or occupied (or V2 < 1.3 V DC)Potentiometer for voltage adjustment V2 = 3.0 V DC 0.10 V

    Si 1

    0,2A

    F/U

    F/U

    0 V

    U

    U

    ..

    . .

    Counting head (systems 1 and 2 of double wheel detector)

    Counting head fuse (0.2 A)

    Figure 8 Front view of VESBA board

    The functions of the VESBA amplifier, trigger and band-pass filter board are as follows:

    connection of ZP 43 E/V wheel detection equipment (counting heads) forwarding of power supply (from SVK2150) to counting heads

    The counting head is connected to the Az S 350 U via a two-core cable. There are additional outputs on the VESBA board allowing to set up a digital double-usage interface.

    The VESBA board provides electrical isolation between outdoor equipment (counting head) and indoor equipment. It splits the signal frequencies f1 and f2 into two independent channels and filters, amplifies, rectifies and evaluates (trigger) the data transmitted from the counting head.

    The front panel incorporates measuring sockets for fault diagnosis, LEDs for displaying the traversal state and potentiometers for adapting to different cable lengths and setting the transmission levels.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 28 of 89 Copyright Siemens AG 2001 All Rights Reserved

    When the yellow LEDs on the front panel light up, they indicate that a train is traversing or occupying the track-installed wheel detector. In normal operation, these LEDs light up shortly depending on the speed of the train.

    If one of the LEDs is permanently on, there is probably a wheel at the position where the wheel detector is mounted. If this is not the case, a fault can be assumed. The LEDs light up if no counting head is connected or if the voltage supply for the counting head is not present, interchanged or maladjusted (V < 1.3 V or counting head connected incorrectly). Approx. 60/70 V DC must be measured at the terminals for the counting heads. If no voltage is measured, the fuses must be checked.

    The counting heads are protected via fuse Si 1, which is mounted directly on the front panel, and another fuse on the printed circuit board.

    Comb coding no.: 6 55 according to C25117-A55-A3-*-18

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 29 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.7 DIGIDO Board

    Digital double-usage board S25552-B699-U1

    Figure 9 Front view of DIGIDO board

    The optional DIGIDO board is used to switch through the digital axle signals between the Az S (M) 350 Version B/M and the Az S 350 U. For digital double usage (from and to other systems) either the digitised WDE signals of the directly connected counting heads as transmitting counting heads can be used or the digitised WDE signals of another evaluation computer are used instead of the directly connected counting heads.

    The DIGIDO board performs two functions:

    The digital axle signal (TTL level) coming from the VESBA board (Az S 350 U) is inverted, decoupled via an optocoupler and forwarded to the STEU board of the Az S (M) 350 Version B/M via an IMA module.

    The digital axle signal (TTL level) coming from the VESTI board (Az S (M) 350 Version B/M) is inverted, decoupled via an optocoupler and forwarded to the STEU board of the Az S 350 U.

    Front connector coding no.: 3001 according to C25117-A55-A1-*-18

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 30 of 89 Copyright Siemens AG 2001 All Rights Reserved

    3.8 SVK2150 Power Supply Board

    Power supply board S25552-B651-C1

    SVK2150

    12 V

    I0

    ON/OFF

    On/Off switch forpower supply board

    0,1 AF

    5 V

    70 V

    Vin

    Yellow LED: 12 V Not used in the Az S 350 U

    Yellow LED: 5 V

    Yellow LED: 70 V

    Yellow LED: Vin

    Fuse: 0.1 A (fast)

    Computer voltage present

    WDE supply voltage present

    Input voltage present

    Figure 10 Front view of SVK2150 power supply board

    The SVK2150 board converts the interlocking voltage into controlled voltages of 5 V DC for the computer, 12 V DC (not in use) and 70 V DC for WDE supply. All voltages are monitored by voltage controllers. Input and output voltages are electrically isolated.

    The SVK2150 board is ready for operation when voltage is applied to the switching input. This is indicated by the yellow LED "Vin". When the switch on the front panel is set to "I", the yellow LEDs "5 V" and "70 V" ("12 V" is not used) indicate the presence of the voltages.

    In case of undervoltage, the output voltage is switched off. When the output voltage is missing, the control-circuit fuse (fuse 0.1 A; fast) on the front panel blows. The unit cannot go back into operation until this fuse has been replaced.

    If there is no voltage at all, the input fuse on the printed circuit board (fuse 8 A; slow-acting) has to be checked.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 31 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The SVK2150 power supply board supplies voltage for up to five counting heads connected. Terminal strips connected to the SVK2150 ensure electrical isolation between indoor and outdoor equipment. Counting heads 4 and 5 may also be supplied from another voltage source, e.g. directly from the interlocking battery. On the wiring backplane, terminal strips are available for connecting counting heads 4 and 5, the corresponding connections being established via jumper wires.

    Comb coding no.: 2 09 according to C25117-A55-A3-*-18

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 32 of 89 Copyright Siemens AG 2001 All Rights Reserved

    4 Diagnostics

    4.1 Fault Indication

    Track sections whose track vacancy detection equipment is faulty are indicated as being occupied in the control room. After detecting the fault or failure, the signaller (or authorised person) informs the maintenance staff.

    4.2 Troubleshooting (Indoor Equipment)

    Troubleshooting should start in the indoor equipment (evaluation computer). Record and evaluate the current operating state displays. If the fault could not be eliminated by means of an axle count reset operation

    by the signaller (or authorised person), press the AzGrH button on one channel in order to activate the statistics functions and record and evaluate the statistical data. For further details, see Section 4.3 "Statistics Functions/Diagnostics", page 33.

    To pinpoint the causes of counting errors, remeasure the signal frequencies f1 of 3.60 kHz (tolerance range from 3.55 kHz to 3.65 kHz) and f2 of 6.52 kHz (tolerance range from 6.42 kHz to 6.62 kHz) at the measuring sockets "f1" for 3.60 kHz and "f2" for 6.52 kHz. In addition, remeasure the output voltages V1 (3.0 V DC) and V2 (3.0 V DC) at the measuring sockets "U" of the VESBA board. The values must lie within the admissible tolerance range (2.90 V to 3.10 V).

    If the signal frequencies f1, f2 and the voltages V1, V2 are within the admissible tolerance range, the cause of fault is most probably to be found in the evaluation computer.

    If the voltages are outside the admissible tolerance range, check the counting head. If the counting head proves fault-free, check the transmission path (cable). If the signal frequencies f1 and/or f2 are outside the admissible tolerance range, check the counting head.

    Before checking the outdoor equipment, check whether the fuse on the VESBA board (0.2 A) in the evaluation computer is fault-free and if there is WDE supply voltage present in the indoor equipment. The tests are carried out with the FTGS/GLS/AZS test unit (PEGA 1211), the test adapter board for ZP 43 E/V in conjunction with a multimeter or the WDE diagnostic unit (no longer available) and by comparison with the values given in the table of measured values. Faulty boards must be replaced.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 33 of 89 Copyright Siemens AG 2001 All Rights Reserved

    4.3 Statistics Functions/Diagnostics

    NOTE The diagnostic mode is exclusively activated via a single-channel AzGrH operation! A dual-channel AzGrH operation results in an occupied indication for the TVDS!

    STEU 1Channel 1(left board)

    STEU 2Channel 2

    (right board)

    2 xx

    0123456789

    1011

    Diagn.

    2 xx

    0123456789

    1011

    Diagn.

    LEDs for statistics function selection

    STEU 1Channel 1(left board)

    STEU 2Channel 2

    (right board)

    2 xx

    0123456789

    1011

    Diagn.

    2 xx

    0123456789

    1011

    Diagn.

    Display of statistics function selected

    Display of resultfor selected

    statistics function

    LED

    s fo

    rdi

    spla

    y of

    resu

    lts

    LEDs forobject selection

    Select withAzGrH button

    Result

    Display of object selected(CH, TVDS, block information

    or system information selectable)

    Figure 11 Front view of STEU board; statistics display

    Single-channel operation of the auxiliary axle count reset button (AzGrH) connected with the BLEA12 board switches the STEU boards from normal to statistics display. The LEDs on STEU 2 to the right (slot 57) show the selectable options. The object selection menu consists of two groups of five LEDs each. The upper LED group (LED 1 to LED 5) displays the type of object selected, the lower group (LED 7 to LED 11) displays the statistics function selected. The result of the selection is displayed (directly or in binary code) on the STEU 1 board to the left (slot 27, LEDs 0 to 11).

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 34 of 89 Copyright Siemens AG 2001 All Rights Reserved

    4.3.1 Selection

    The statistics display (for diagnostic purposes) is activated by pressing one of the two AzGrH buttons for about 3 s (single-channel operation, use TVDS 1 button).

    Activating statistics display (default display) after system start:

    Press AzGrH (for approx. 3 s, use TVDS 1 button)

    Display on STEU 2

    LED display

    ! = on (steady light), selection possible

    = flashing, selection not possible

    Object currently selected

    Result displayed on STEU 1

    Activating statistics display

    Object selection enabled (default)

    LED 1 = ! LED 7 =

    CH 1: object selection enabled; statistics function not selectable

    Statistics function: axle count for CH 1; (default)

    2 xx

    0123456789

    1011

    Diagn.

    STEU 2STEU 1

    2 xx

    0123456789

    1011

    Diagn.

    Selection:

    Selection:statisticsfunction

    1

    7

    One or more LEDs on:selection possible

    - object selection enabled;CH 1 selected

    Object can be selected

    One or more LEDs flashing:selection not possible

    Statistics function cannot be selected

    CHTVDS

    Block infoSystem info

    Figure 12 Display on STEU 2 board; starting the statistics display

    After system start-up and subsequent switching to statistics function display, the default setting is applied. LED 1 is permanently on, the object selection on the right STEU 2 board is enabled, and LED 7 is flashing (statistics function selection currently not possible).

    NOTE The AzGrH button connected to the BLEA12 board in slot 71 or 63 (see Section 5.4.2 "Special Conditions for BLEA12 Board") permits you to jump forward. To jump back, use the AzGrH button connected to the BLEA12 board in slot 11. The user is guided through the object selection procedure by LEDs being permanently on (selection enabled/item selected) or flashing (selection not possible/item not selected).

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 35 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The object selection option allows to obtain statistical information either on a certain counting head (CH 1 to CH 5) or a certain track vacancy detection section (TVDS 1 to TVDS 4). Further selectable objects are block info (input, output, block information distribution) and system info (e.g. software version). By pressing the AzGrH button shortly ( 1 s), you can switch between the selectable objects.

    Switching from CH to TVDS within the object selection menu:

    Press AzGrH several times ( 1 s)

    Display on STEU 2

    LED display*

    ! = on (steady light), selection possible

    = flashing, selection not possible

    Object currently selected

    Result displayed on STEU 1

    Object currently selected: CH

    Object selection enabled

    LED 1 = ! LED 7 =

    CH 1: Object selection enabled; statistics function not selectable

    Statistics function: axle count for CH 1

    Switching from CH to TVDS

    Object selection enabled

    LED 1 = ! LED 5 = ! LED 7 =

    TVDS 1: Object selection enabled; statistics function not selectable

    Statistics function: axle count for TVDS 1

    *The description of the column >LED display< can be found in Section 4.3.2 "LED Display Tables for Selection Options".

    2 xx

    0123456789

    1011

    Diagn.

    STEU 2STEU 1

    2 xx

    0123456789

    1011

    Diagn.

    Selection:

    Selection:statisticsfunction

    1

    7

    One or more LEDs on:selection possible

    - object selection enabled;switched to TVDS 1

    Object can be selected

    One or more LEDs flashing:selection not possible

    Statistics function cannot be selected

    CHTVDS

    Block infoSystem info5

    Figure 13 Example of display on STEU 2 board; TVDS 1 selected

    By repeatedly pressing the AzGrH button within the object selection menu, further objects can be selected. The corresponding LEDs will light up. Example: LED 1 and LED 5 being permanently on indicates that TVDS 1 has been selected. Further selections are possible by actuating the AzGrH button again ( 1 s).

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 36 of 89 Copyright Siemens AG 2001 All Rights Reserved

    After object selection is terminated, the type of statistical information to be displayed for the CH, TVDS, block info or system info can be selected by pressing the AzGrH button for > 1 s 3 s.

    Switching from object selection to statistics function selection:

    Press AzGrH (> 1 s 3 s)

    Display on STEU 2

    LED display*

    ! = on (steady light), selection possible

    = flashing, selection not possible

    Object currently selected

    Result displayed on STEU 1

    Object currently selected: CH

    Object selection enabled

    LED 1 = ! LED 7 =

    CH 1: Object selection enabled; statistics function not selectable

    Statistics function: axle count for CH 1

    Switch to select statistics functions for CH

    Statistics function selection enabled

    LED 1 = LED 7 = !

    CH 1: Object selection disabled; statistics function selectable, function type 1 currently selected

    Function type 1; axle count for CH 1 since last system start-up

    *The description of the column >LED display< can be found in Section 4.3.2 "LED Display Tables for Selection Options".

    Object cannot be selected

    Statistics function can be selected

    One or more LEDs on:selection possible

    - statistics selection enabled;function type 1 for CH 1

    selected

    One or more LEDs flashing:selection not possible- object CH 1 selected

    2 xx

    0123456789

    1011

    Diagn.

    STEU 2STEU 1

    2 xx

    0123456789

    1011

    Diagn.

    Selection:

    Selection:statisticsfunction

    7

    CHTVDS

    Block infoSystem info

    1

    Figure 14 Example of display on STEU 2 board; switching to statistics functions

    LED 7 being permanently on means that function type 1 has been selected. LED 1 flashing means that the object selection is currently not enabled.

    Pressing the AzGrH button once again ( 1 s) (jumping forward) enables different statistics function types to be selected. You can also jump back again

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 37 of 89 Copyright Siemens AG 2001 All Rights Reserved

    (watch the LED display). Pressing the AzGrH button for a longer time (> 1 s 3 s) will bring you back to the object selection menu.

    If the AzGrH button is pressed for more than 3 s, the system quits the statistics selection function and the display on the STEU board returns to 'normal'.

    4.3.2 LED Display Tables for Selection Options

    The display and meaning of the selection options on the STEU board are explained in the following LED display tables:

    Object selection CH Object selection TVDS Object selection block info Object selection system info Statistics function options Meaning of statistics function types CH Meaning of statistics function types TVDS

    meaning after selection of function type 2 operating state Meaning of statistics function types block info Meaning of statistics function types system info

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    STEU2 STEU1

    2 xx 0123456789

    1011

    Diagn.

    Selection:

    Selection: Statistics function

    1 CH TVDS

    Block info System in fo

    Press AzGrH

    7

    0 2 3 5

    LED n o. LED dis pla y :

    1

    2

    3

    4

    5

    C H s el ect ed 1 2 3 4 5

    Object selec tion - CH

    Object selec tion - TVDS

    Statistics function options

    M eaning of statistics function types - CH -

    M eaning of statistics function types - TVDS

    LED no . LED -displ a y

    1

    2

    3

    4

    5

    B loc k info

    O bject selec tion s ys tem infoLED no n. LED displ a y

    1

    2

    3

    4

    5

    S yste m info

    Object selec tion bloc k info

    LED Be de utu ng n ac h Aus wa hl d er F u n kti ons ar t B etrie bsz ustan d (nur Obj e kt - Aus wa hl GFM )

    .... ... .... ... ... ... ... ... .... ... ... ... ... ... .... ... ... ... ... ... .... ... ... ... ... 0

    .... ... .... ... ... ... ... ... .... ... ... .

    .... ... .... ... ... ... ... ... .... ... ..

    .... ... .... ... ... ... ... ... . ... .... ... .... ... ... ... ... ... .... ... ... ... ... ... ....

    11 .... ... .... ... ... ... ... ... .... ... M eaning of statistics function types bloc k info

    Func tion type Meaning of sta tis tics function type (CH) 1 .................. ......... .................................. ......... ........................................... ... 2 .................. ......... ............

    .

    ..........

    .........

    .............................. .................................. .....

    .............................. ..............

    12 ........................... ...................

    M eaning of statistics function types - s ystem info

    LED n o. LED dis pla y :

    1

    2

    3

    4

    5

    TVD Sse le cted 1 2 3 4

    Func tion type Meaning of sta tis tics function type (block info) 1 ........ .................................. .................................

    . ........ .................................. .................................

    7 ........ .................................. . . .......... .....................

    LED no . LED displ a y : 7 8 9

    10 11

    Fun ction T ype s el e cted 1 2 3 4 5 6 7 8 9 10 11 12

    Func tion type Meaning of sta tis tics function type (system info) 1 .................. ......... .................................. ..............

    . .................. ......... .................................. ..............

    8 .................. ......... ............... ... .............................. 8

    Hierzu gehrt LED 8R elates to table LED on

    Func tion type Meaning of sta tis tics function type (TVDS) 1 ........ .................................. ............................................ ......... ..................... 2 Op erating s ta te

    .

    ......... .

    ........ .

    . .......... ........................................... ...............

    ........... .................................

    10 ........ .................................. ....

    B edeutung nac h Auswahl Funktions art B etriebszustaM ean ing after s election of function type 2 - op . state

    Figure 15 Overview: Assignment of tables to selection options

    The meaning of LED displays can be found in the respective table.

    After selecting an object (CH, TVDS, block info, system info), the statistics function type for this object is chosen. The statistics function types available for

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 38 of 89 Copyright Siemens AG 2001 All Rights Reserved

    the objects CH, TVDS, block info and system info are listed in the table "Meaning of statistics function types".

    The respective LED display is selected with the help of the table "Statistics function options". The table "Meaning after selection of statistics function type 2 - operating state" is relevant only to statistics function type "Operating state" (function type 2; TVDS table only). See also Section 4.3.3 "Examples of Option Selection", page 47.

    You want to display the statistical information for the object CH:

    LED no. LED display: ! = on, = off

    1 2 3 4 5

    CH selected 1 2 3 4 5

    Table 1 Object selection - CH

    The upper LED group (LED 1 to LED 5) displays which CH object has been selected (CH 1 to CH 5).

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 39 of 89 Copyright Siemens AG 2001 All Rights Reserved

    You want to display the statistical information for the object TVDS:

    LED no. LED display: ! = on, = off

    1 2 3 4 5

    TVDS selected

    1 2 3 4

    Table 2 Object selection TVDS

    The upper LED group (LED 1 to LED 5) displays which TVDS has been selected (TVDS 1 to TVDS 4). This indication is based on a combination of two LEDs being on.

    You want to display the statistical information for the object Block info:

    LED no. LED display: ! = on, = off

    1 2 3 4 5

    Block info selected

    Table 3 Object selection Block info

    The upper LED group (LED 1 to LED 5) displays which item of block information has been selected. This indication is based on a combination of more than one LED being on.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 40 of 89 Copyright Siemens AG 2001 All Rights Reserved

    You want to display the statistical information for the object System info:

    LED no. LED display: ! = on, = off

    1 2 3 4 5

    System info selected

    Table 4 Object selection System info

    The upper LED group (LED 1 to LED 5) displays which item of system information has been selected. This indication is based on a combination of more than one LED being on.

    The respective LED display is selected with the help of the table "Statistics function options" (table refers to object types CH, TVDS, block info and system info):

    LED no. LED display: ! = on, = off

    7 8 9

    10 11

    Function type

    selected

    1 2 3 4 5 6 7 8 9 10 11 12

    Table 5 Statistics function options (CH, TVDS, block info, system info)

    The lower LED group (LED 7 to LED 11) on the right STEU 2 board displays the statistics function type which has been selected. This indication is based on one LED or more LEDs being on.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 41 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The description of the statistics function types for the object CH can be found in the following table:

    Function type

    Description of function type (for CH)

    1 Current axle count of counting head selected since last system start-up. The system carries out a signed addition of the axles traversing the counting head (+1 for axles from left to right, -1 for axles from right to left).

    2 Fault count of counting head selected

    3 Bit 0 ... 7: Bit 8:

    Time elapsed since last pulse detection by CH (*0.07 s) Count monitoring fault

    4 Total number of axles since last system start-up, bits 0 ... 11

    5 Total number of axles since last system start-up, bits 12 ... 23

    6 Total number of axles since last system start-up, bits 24 ... 31

    7 Total number of trains since last system start-up, bits 0 ... 11

    8 Total number of trains since last system start-up, bits 12 ... 23

    9 Total number of suppressed faults since last system start-up

    10 Total number of short trains (< 13 ms) since last system start-up

    11 Total number of power supply failures since last system start-up

    12 Total number of changes in channel state (G and X transitions) since last system start-up

    Table 6 Description of statistics function types for counting head

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 42 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The description of the statistics function types for the object TVDS can be found in the following table:

    Function type

    Description of function type (for TVDS)

    1 Current axle count of track vacancy detection section selected since last system start-up. The system carries out a signed addition of the axles traversing the counting head (+1 for axles from left to right, -1 for axles from right to left).

    2 Operating state (additional information for normal display)

    Restriction register XDEINS: 3

    Bit 0: Bit 1:

    Reset restriction (ZGREIN) AzGrT not effective (ZAZGSP)

    Monitoring register XDUEBE: 4

    Bit 3: Bit 5: Bit 7:

    Monitoring fault (ZZUEBE) AzGrT actuated (ZAGBED) Section stable (ZSTABL)

    1st clear indication register XDFMRG: 5

    Bit 0: Bit 2:

    Track relay channel 1 (ZFMAN) Inverted AzGrT acknowledgement bit (GT)

    2nd clear indication register XDFMRG+1: 6

    Bit 0: Bit 2:

    Track relay channel 2 (ZFMAN) Reset restriction off (GE)

    7 Previous operating state (before last AzGrT actuation)

    8 Previous axle count (before last AzGrT actuation)

    9 Total number of occupations since last system start-up, bits 0 ... 11

    10 Total number of occupations since last system start-up, bits 12 ... 23

    11 No function! Display: Even and odd LEDs flash alternately

    12 No function! Display: Even and odd LEDs flash alternately

    Table 7 Description of statistics function types for track vacancy detection section

    The LED display for the statistics function type (for TVDS) is then selected with the help of the table "Statistics function options".

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 43 of 89 Copyright Siemens AG 2001 All Rights Reserved

    If statistics function type 2 for TVDS (operating state) has been selected; the operating state for a selected TVDS (TVDS 1, 2, 3 or 4) is indicated on the left STEU 1 board. The following table explains the LED display:

    LED Meaning of display after selection of function type "operating state" (for TVDS object only)

    0 Reset buttons of evaluation computer have been pressed. AzGrT must be actuated.Flashing LED: System failure

    1(*) Minus axle blocking effective Counting capacity exceeded Undefined counted pulse

    2 Count monitoring

    3 Telegram transmission between evaluation computers is or was faulty or shutdown of second evaluation computer

    4 Reset restriction

    5 TVDS not clear; axle count not equal to zero, or one of the other LEDs is on

    6 AzGrT inputs asynchronous

    7 AzGrH buttons have been actuated

    8 TVDS unstable

    9 Block input of second evaluation computer asynchronous

    10 Counting capacity exceeded

    11 Undefined counted pulse

    Table 8 Meaning of display after selection of function type 2 operating state

    NOTE (*) The LEDs 1, 10 and 11 display, individually or in combination, the following:

    LED no. LED display : ! = on, = off

    1 10 11

    Meaning Minus axle blocking block effective

    Counting capacity exceeded

    Undefined counted pulse

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 44 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The description of the statistics function types for the object Block info can be found in the following table:

    Function type

    Description of function type (block info)

    1 Item of block information OUT 1 12, channel 1; 1st pair of BLEA12

    2 Item of block information OUT 1 12, channel 2; 1st pair of BLEA12

    3 Item of block information OUT 13 24, channel 1; 2nd pair of BLEA12

    4 Item of block information OUT 13 24, channel 2; 2nd pair of BLEA12

    5 Item of block information IN 1 12, channels 1 and 2; 1st pair of BLEA12

    6 Item of block information IN 13 24, channels 1 and 2; 2nd pair of BLEA12

    7 Distribution of block information for 1st pair of BLEA 12 boards (DIP switches B0 B4)

    8 Distribution of block information for 2nd pair of BLEA 12 boards (DIP switches B0 B5 and CHANG1, CHANG2)

    9 No function! Display: Even and odd LEDs flash alternately

    10 No function! Display: Even and odd LEDs flash alternately

    11 No function! Display: Even and odd LEDs flash alternately

    12 No function! Display: Even and odd LEDs flash alternately

    Table 9 Description of statistics function types for block information

    NOTE The contents of the items of block information are specified by the railway operator.

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 45 of 89 Copyright Siemens AG 2001 All Rights Reserved

    The description of the statistics function types for the object System info can be found in the following table:

    Function type

    Description of function type (for system info)

    1 Software version

    2 Software date: DAY (bits 0 7); MONTH (bits 8 11)

    3 Software year: bits 0 7

    Software variant: 4 LED 0 on STEU 1: LED 1 on STEU 1: LED 2 on STEU 1: LED 3 on STEU 1: LED 7 on STEU 1:

    Level crossing software Software for China, TVDS-specific Software for China, CH-specific Decentralised electric points software CH test pulse during system start

    5 Address of SIRIUS2 board, channel 1

    6 Address of SIRIUS2 board, channel 2

    Software operating mode from channel 1 7 LED 0, 1 on STEU 1: LED 2 on STEU 1: LED 3 on STEU 1: LED 4 on STEU 1: LED 5 on STEU 1 LED 6 on STEU 1: LED 7 on STEU 1:

    vAzGr mode Clear indication via AzGr CHFMOUT TELFM TD (channel 1) Axle oscillation Baud rate (channel 1)

    Software operating mode from channel 2 8 LED 0, 1 on STEU 1: LED 2 on STEU 1: LED 3 on STEU 1: LED 4 on STEU 1: LED 5 on STEU 1: LED 6 on STEU 1: LED 7 on STEU 1:

    vAzGr mode Clear indication via AzGr CHFMOUT TELFM TD (channel 2) Axle oscillation Baud rate (channel 2)

    9 No function! Display: Even and odd LEDs flash alternately

    10 No function! Display: Even and odd LEDs flash alternately

    11 No function! Display: Even and odd LEDs flash alternately

    12 No function! Display: Even and odd LEDs flash alternately

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 46 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Determining the display result:

    The display result on the left STEU 1 board is determined using the dual system approach. The result can be calculated by summing up the values of the LEDs that are on.

    LED no. Exponent of 2 Value

    0 (20) 1

    1 (21) 2

    2 (22) 4

    3 (23) 8

    4 (24) 16

    5 (25) 32

    6 (26) 64

    7 (27) 128

    8 (28) 256

    9 (29) 512

    10 (210) 1024

    11 (211) 2048

    Table 10 Determining the display result using the LED display on left STEU 1

    Display example: LEDs being

    permanently on

    Value

    0 1

    2 4

    4 16

    6 64

    Total 85

    Table 11 Example of result calculation

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 47 of 89 Copyright Siemens AG 2001 All Rights Reserved

    4.3.3 Examples of Option Selection

    Example: Statistics function for CH object

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    STEU 2 STEU 1

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    Selection

    SelectionStatistics function

    CHTVDS

    Block info System info

    Press AzGrH

    8 Relates to table LED on

    LED n o. LED dis pla y :

    1

    2

    3

    4

    5

    CH s el ect ed 1 2 3 4 5

    LED no LED display:7 8 9 10 11

    Functitype selected? 1 2 3 4 5 6 7 8 9 10 11 12

    Function Meaning of statistics function type (for CH) 1 ..........................................................................................................

    2 ....................................

    .

    ...................

    ...............................................................

    .........................................

    12 ...........................................

    Table:Object selection - CH

    Table: Meaning of statistics function types - CH

    Table: Statistics function options

    1. 1.

    2

    LED 7 for function type 1

    1

    1. Type1 Current axle count .... 2

    7 5 2 3

    4.

    3.

    Select function type:Function type 1

    for CH 2 iscurrent axle count ...

    2.Select CH:LED 2 on

    for CH 2

    Result for CH 2 Current axle count

    (binary coded) 6.

    5.

    Operating step

    0 2

    7

    Example: Procedure for selection of object CH 2, function type 1 - Current axle count

    Operating step

    Description Press AzGrH (one channel)

    Comments

    0 Switch to statistics display

    > 3 s Press AzGrH of TVDS 1

    1 Select CH 1 s See table: "Object selection - CH"; example: LED 2 is on for CH 2

    2 Select statistics function type for object selected (CH)

    See table "Description of statistics function types for CH"; example: function type 1 (current axle

    count...) selected

    3 and ... Switch from object selection to statistics function type selection

    > 1 s 3 s First: LED 2 on, LED 7 flashing Then: LED 2 flashing, LED 7 on

    ... 4 See table for LED display for statistics function type

    See table "Statistics function options"; example: LED 7 for function type 1

    5 and ... Select statistics function type

    1 s LED 7 is on for function type 1

    ... 6 Read result from STEU 1 board

    Binary-coded result

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 48 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Example: Statistics function for TVDS object

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    STEU 2 STEU 1

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    Selection:

    Selection:Statisticsfunction

    CH TVDS

    Block infoSystem info

    Press AzGrH

    LED no. LED display :

    1

    2

    3

    4

    5

    W elcherTVDS 1 2 3 4

    LED no. LED display : 7 8 9

    10 11

    Function type selected 1 2 3 4 5 6 7 8 9 10 11 12

    Function type Meaning of statistics function type (for TVDS) 1 .................................................................................................................... 2 Betriebszustand

    .

    ..........

    .........

    .....................................................................

    ............................................

    10 ..............................................

    LED Meaning of display after selec tion of functi on type 2 Oper ati ng state For TVDS

    ........... ... ... ... ... ... .... ... ... ... ... ... .... ... ... ... ... ... .... ... ... ... ... 0

    ........... ... ... ... ... ... .... ... ... .

    ........... ... ... ... ... ... .... ... ..

    ........... ... ... ... ... ... . . . . ........... ... ... ... ... ... .... ... ... ... ... ... ....

    11 ........... ... ... ... ... ... .... ...

    Table:Object selection - TVDS

    Type 2

    Table: Meaning of statistics function types - TVDS

    Table: Statistics function options

    Operating state

    TVDS occupied; axle count ...

    8

    5

    4

    2

    Select function type:Function type 2 for TVDS 4 is

    operating state

    2.

    Select TVDS: LEDs 4, 5 on

    for TVDS 4

    1.

    3.

    4 5 8

    5

    LED 8 for function type 2

    4.

    5. 6.

    Result for TVDS 4 -

    Operating state 7.8 Relates to table LED on 1. 1. Operating step

    45

    Example: Procedure for selection of object TVDS 4, function type 2 Operating state

    Operating step

    Description Press AzGrH (one channel)

    Comments

    0 Switch to statistics display

    > 3 s Press AzGrH of TVDS 1

    1 Select TVDS 1 s See table "Object selection - TVDS"; example: LEDs 4, 5 are on for TVDS 4

    2 Select statistics function type for object selected (TVDS)

    See table "Description of statistics function types for TVDS"; example: function type 2 (operating

    state) selected

    3 and ... Switch from object selection to statistics function type selection

    > 1 s 3 s First: LEDs 4, 5 on, LED 7 flashing Then: LEDs 4, 5 flashing, LED 7 on

    ... 4 See table for LED display for statistics function type

    See table "Statistics function options"; example: LED 8 for function type 2

    5 and ... Select statistics function type

    1 s LED 8 on for function type 2

    ... 6 Read result from STEU 1 board

    Result

    7 Interpret result See table "Meaning of display after selection of function type 2 Operating state";

    example: LED 5, TVDS occupied (...)

  • Transportation Systems

    Maintenance Instructions M0110058886 Rev: C Az S 350 U A25552-C605-U1-3-7620 0000MINB.doc 2004-02-06 =009470&EWT026 Page 49 of 89 Copyright Siemens AG 2001 All Rights Reserved

    Example: Statistics function for block info object

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    STEU 2 STEU 1

    2 x x 0 1 2 3 4 5 6 7 8 9

    10 11

    Diagn.

    Object selection:

    Selection:Statisticsfunction

    CH TVDS

    Block infoSystem info

    Press AzGrH

    LEDno. LEDdisplay

    1

    2

    3

    4

    5

    Blockinfo

    Function type Meaning of statistics function type (block info) 1 ........................................................................... . ........................................................................... 7 ........................................... ................................

    LED no. LED display 7 8 9

    10 11

    Functiotype selected 1 2 3 4 5 6 7 8 9 10 11 12

    Table:Object selection Block info Table: Meaning of statistics function types Block info

    Table: Statistics function options

    LED 7 for function type 1

    1

    Type 1 Block info OUT 1 12 ...

    7

    3

    7 5

    2 3

    4.

    3.

    Result for block info Block info OUT 1 - 12

    (binary coded)

    6.

    5.

    0

    Select function type:Function type 1 for block info is

    block info OUT 1 -12 ...

    Select itemof block info:

    LEDs 1, 3, 5 on

    1. 1

    5

    2.

    8 LED leuchtet 8 LED on 1.1. Operating step

    135

    Example: Procedure for selection of object Block info, function type 1 Item of block information 1-12 ...

    Operating step

    Description Press AzGrH (one channel)

    Comments

    0 Switch to statistics display

    > 3 s Press AzGrH of TVDS 1

    1 Select item of block information

    1 s See table "Object selection Block info"; example: LEDs 1, 3, 5 are on for block info

    2 Select statistics function type for object selected (block info)

    See table "Description of statistics function types for block info"; example: function type 1 (item of

    block information OUT 1-12 ...) selected

    3 and ... Switch from object selection to statistics function type selection

    > 1 s 3 s First: LED 2 on, LED 7 flashing Then: LED 2 flashing, LED 7 on

    ... 4 See table for LED display for statistics function type

    See table "Statistics function options"; example: LED 7 for function type 1

    5 and ... Select statistics function type

    1 s LED 7 on for function type 1

    ... 6 Read result from STEU 1 board