Top Banner
©Toshiba Medical Systems Corporation 2013. All rights reserved. Design and specifications subject to change without notice. Model number: TSX-303A MCACT0240EA 2013-02 TME/D http://www.toshibamedicalsystems.com Printed in Japan Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485. Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001. Made for Life, Aquilion, SURE Exposure, SURE Cardio, SURE Plaque and SURE Subtraction are trademarks of Toshiba Medical Systems Corporation. MAIN SYSTEM SPECIFICATIONS Maximum number of slices 160 slices/rotation Fastest rotation time 0.35 s Maximum generator power 72 kW X-ray tube unit heat capacity 7.5 MHU Gantry bore 78 cm Reconstruction speed Up to 60 fps* with AIDR 3D Low contrast resolution 2 mm @ 0.3% APPLICATIONS (OPTIONS) • Shuttle Helical Scan System • Brain Perfusion • CBP Study • ECG Gated Scan System SURE Cardio Scoring SURE Plaque • Cardiac Function Analysis SURE Subtraction • vHP (variable Helical Pitch) • Vessel View • Lung Volume Analysis • Body Perfusion • Colon View • Dual Energy System • Fat Index View * Option
2

MAIN SYSTEM SPECIFICATIONS APPLICATIONS (OPTIONS)

Oct 18, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MAIN SYSTEM SPECIFICATIONS APPLICATIONS (OPTIONS)

©Toshiba Medical Systems Corporation 2013. All rights reserved.Design and speci�cations subject to change without notice.Model number: TSX-303A MCACT0240EA 2013-02 TME/D

http://www.toshibamedicalsystems.com

Printed in Japan

Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485.

Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001.

Made for Life, Aquilion, SUREExposure, SURECardio, SUREPlaque and SURESubtraction are trademarks of Toshiba Medical Systems Corporation.

MAIN SYSTEM SPECIFICATIONS

Maximum number of slices 160 slices/rotation Fastest rotation time 0.35 sMaximum generator power 72 kWX-ray tube unit heat capacity 7.5 MHUGantry bore 78 cmReconstruction speed Up to 60 fps* with AIDR 3DLow contrast resolution 2 mm @ 0.3%

APPLICATIONS (OPTIONS)

•ShuttleHelicalScanSystem•BrainPerfusion•CBPStudy•ECGGatedScanSystem•SURECardio™Scoring•SUREPlaque™

•CardiacFunctionAnalysis•SURESubtraction™

•vHP(variableHelicalPitch)•VesselView•LungVolumeAnalysis•BodyPerfusion•ColonView•DualEnergySystem•FatIndexView

* Option

Page 2: MAIN SYSTEM SPECIFICATIONS APPLICATIONS (OPTIONS)

AIDR 3D off AIDR 3D on

High-end CT system for your clinical needs today and in the future

Aquilion™PRIMEincorporatescutting-edgetechnologiesdesignedtomeetyourcurrentandfutureclinicalneeds.

Innovativefeaturesensurethathigh-qualityimagesforbestpossiblediagnosisareroutinelyacquiredwithlowestpossible patient dose. The workflow is streamlined increasing your patient throughput and reducing waiting times.

For a dose reduction technology to be truly useful in clinical practice, it must be fast enough to fit into busy workflow schedules. AIDR 3D reconstruction has therefore been systematically optimized to guarantee maximumonpatientthroughput.Asaresult,advancediterativereconstructionwithAIDR3Dcanbeusedforeverypatientandeveryscan.

INTEGRATED DOSE REDUCTION

Minimization of the radiation dose is a high priority for all medical imaging practitioners. The dose has to be adjusted appropriately according to the sizeandshapeofeachpatient.Automaticexposurecontrolsystemshaveproventobeusefulindoingthiswhilemaintainingdiagnosticimagequality.

Toshiba’s SUREExposure™3Dadaptiveexposurecontrolsystemisfullyintegrated into the imaging chain and can therefore calculate the minimum radiationexposurerequiredforeachexaminationofeachpatient.WiththeinclusionofAdaptiveIterativeDoseReduction3D(AIDR3D)inthescan protocol, the exposure dose is automatically reduced by up to 75% relativetothatinascanperformedwithtraditionalfilteredback-projectionreconstruction.

SHUTTLE HELICAL SCANNING*

Multiphase shuttle helical scanning can be used toacquiredynamicvolumedatainwhole-brainperfusion studies*. The analysis software performs 3Dperfusionprocessingand3DCTDSAusingthesame scan data.

ULTRA FAST HELICAL SCANNING

Routine 0.35 second ultra fast helical scanning with 80 detector rows ensures fast examinations with dramaticallyreducedmotioneffects.Advancedreconstruction algorithms produce artifact-free images with outstanding clarity.

LARGE BORE GANTRY WITH TECH ASSIST LATERAL SLIDE

TheAquilionPRIMEgantryhasa780mmaperture,thelargestavailableinahigh-endCTsystem,ensuringgreaterpatientcomfort.Theuniquepatientcouchisaccurateevenwithaloadof300kg,andistheonlycouch on the market with the technology assisted couch-toplateralslidingfeature*.Patientpositioninghasneverbeeneasier.

* Option**Shortcouchversion

12 cm

4 seconds

SMALL INSTALLATION SPACE

InnovativeredesigningofAquilionPRIMEhasreducedtherequiredinstallationareatojust14.8m2**. This high-end multislice CTsystemhasbeenmade compact enough tomeeteventhemostrestrictivesitingrequirements.