Menu Map Sheet For details on the organization of the menu settings and the method of operation of the menu, see "3. MENU SETTINGS" ( ^page 40). Main Menu Data Output Menu STAND POURING WIN| WIN|.U WIN- WIN-.U Z.TRC APL.FUNC TOOLS FORMULA TG.VAL LM.VAL OVR.RNG PARAM.W STB.MK BAND SYSTEM POINT PERIOD COMMA FAST SAMPLE SAMPLE OPTION General weighing mode WindowsDirect communication function Pouring mode Zero tracking function Application function mode Specific percentage reference Formulation Other functions Target value Permissible range Fast Checkweighing range upper limit Stability mark Weighing parameters System Decimal point indication Period Comma Stability detection range PERCENT Percentage weighing PCS Piece counting TARGT Target mode CHECK.W Checkweighing mode 0.5D 1D 10D 50D 100D 1000D Auto power-off HI.LIM Pass range upper limit LO.LIM Pass range lower limit UND.RNG Checkweighing range lower limit Item number ~ 100% reference AUTO.OFF START BAL.ID AUTO SEM.AUTO MANU COND.OUT RESET Start display Balance ID Menu settings output Menu reset Weighing mode OFF display All segments lit Backlight (TXB series only) PASS.WRD Password P.77 P.77 P.111 P.71 P.87 P.92 P.102 P.104 P.79 P.80 P.42 P.138 P.96 P.139 P.69 P.140 P.53 P.51 P.141 BC.LIT Weight display Press [MENU/ENTER]. MODE.5 Standard settings (MODE1 - MODE5) WIN| APL.PRN AUTO.PRN WIN|.U WIN- WIN-.U WindowsDirect communication function Application output Communication settings Auto print function Continuous output function COMM.SET WIN|.U WIN- WIN-.U WIN| WindowsDirect communication function MODE.1 MODE.2 MODE.3 MODE.4 MODE.U Baud rate BPS SEQ.PRN Output timing change function RET. 0 RET.50 Z.RET Zero return judgment Zero or negative value 50% [300] B. 300 [600] B. 600 [1200] B.1200 [2400] B.2400 Parity PARITY [4800] B.4800 [9600] B.9600 [19.2 K] B. 19.2K [38.4 K] B. 38.4K None P.NONE Odd P.ODD Even P.EVEN Delimiter DELIM CR CR LF LF CR+LF CR+LF Comma COMMA Stop bit STOP Handshake HAND.SHK None HS.OFF S. 1 1 bit S. 2 2 bits Hardware HS.HW DF. 1 Data format 1 Timer H.S.TIM Data format D.FORM Data format 2 DF. 2 Data format 3 DF. 3 Head byte D. HEAD Data length D. LEN Data format 4 DF. 4 Free format DF.FRE P.126 P.108 P.129 P.111 P.106 P.127 P.127 P.127 P.127 P.128 P.128 User-specified settings PRINT.F SOON Software HS.SW Weight display Press [PRINT] for 3 sec. LD. . LD.UL. LD. .Z LD.UL.Z LD.OK. On Ld On -Ld On 0Ld On -0Ld On OK MANU Key operation NO.FIL No filter CONV.K MIN.D Minimum indication User-specified units Conversion factors UNIT-U UNIT- UNIT- mg #1 g UNIT- kg #2 UNIT- ct Weight display Press [UNIT] for 3 sec. Other units cannot be selected in some countries due to legal restrictions. #1: mg cannot be selected on models whose minimum indication is 10 mg or greater. #2: kg cannot be selected on the TWC***L and TXC***L. P.85 P.84 P.83 CAL.EXE GLP.OUT GLP output function Calibration P.CAL E.TEST Calibration of the internal weight (TW series only) Calibration check using an external weight I.CAL I.TEST Span calibration using the internal weight (TW series only) E.CAL Span calibration using an external weight Calibration check using the internal weight (TW series only) P.142 P.64 P.57 P.62 P.56 P.60 Weight display Press [CAL] for 3 sec. Z.TRC Zero tracking function A.TARE Auto tare function SOON TARE.F Zero / tare timing change function P.71 P.74 P.72 P.75 Auto zero function A.ZERO Weight display Press [O/T] for 3 sec. Unit setting menu Calibration menu Zero / tare menu 321-56867-21A Sep. 2009 Press or to search for the menu option. Press to return to the previous menu option. (Pressing for around 3 seconds during menu operation returns you to the weighing mode.) Press to proceed to the next menu option. Refers to a page in the instruction manual. Press to confirm. The default settings (settings when the menu is reset)
2
Embed
Main Menu Data Output Menu - SHIMADZU … Stability mark parameters System Decimal point indication Period Comma Stability detection range PERCENT Percentage weighing PCS Piece counting
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Menu Map SheetFor details on the organization of the menu settings and the method of operation of the menu, see "3. MENU SETTINGS" (^ page 40).
Main Menu Data Output Menu
STAND
POURING
WIN| WIN|.U WIN- WIN-.U
Z.TRC
APL.FUNC
TOOLS
FORMULA
TG.VAL
LM.VAL
OVR.RNG
PARAM.W STB.MK
BAND
SYSTEM POINT PERIOD
COMMA
FAST
SAMPLE
SAMPLE
OPTION
General weighing mode
WindowsDirect communication function
Pouring mode
Zero tracking function
Application function mode
Specific percentage reference
Formulation
Other functionsTarget value
Permissible range
Fast
Checkweighing range upper limit
Stability markWeighing parameters
System Decimal point indication
Period
Comma
Stability detection range
PERCENTPercentage weighing
PCSPiece counting
TARGTTarget mode
CHECK.WCheckweighing mode
0.5D
1D
10D
50D
100D
1000D
Auto power-off
HI.LIM Pass range upper limit
LO.LIM Pass range lower limit
UND.RNG Checkweighing range lower limit
Item number ~
100% reference
AUTO.OFF
START
BAL.ID
AUTO
SEM.AUTO
MANU
COND.OUT
RESET
Start display
Balance ID
Menu settings output
Menu reset
Weighing mode
OFF display
All segments lit
Backlight(TXB series only)
PASS.WRD Password
P.77
P.77
P.111
P.71
P.87
P.92
P.102
P.104
P.79
P.80
P.42
P.138
P.96
P.139
P.69
P.140
P.53
P.51
P.141
BC.LIT
Weight display
Press[MENU/ENTER].
MODE.5
Standard settings (MODE1 - MODE5)
WIN|
APL.PRN AUTO.PRN
WIN|.U WIN- WIN-.UWindowsDirect communication function
Other units cannot be selected in some countries due to legal restrictions.#1: mg cannot be selected on models
whose minimum indication is 10 mg or greater.
#2: kg cannot be selected on the TWC***L and TXC***L.
P.85
P.84
P.83 CAL.EXE
GLP.OUT GLP output function
Calibration
P.CAL
E.TEST
Calibration of the internal weight (TW series only)
Calibration check using an external weight
I.CAL
I.TEST
Span calibration using the internal weight (TW series only)
E.CALSpan calibration using an external weight
Calibration check using the internal weight (TW series only)
P.142
P.64
P.57
P.62P.56
P.60
Weight display
Press [CAL] for 3 sec.
Z.TRC Zero tracking function
A.TARE Auto tare function
SOONTARE.FZero / tare timing change function
P.71
P.74
P.72
P.75
Auto zero functionA.ZERO
Weight display
Press [O/T] for 3 sec.
Unit setting menu Calibration menu Zero / tare menu
321-56867-21A Sep. 2009
Press or to search for the menu option.
Press to return to the previous menu option.(Pressing for around 3 seconds during menu operation returns you to the weighing mode.)
Press to proceed to the next menu option.
Refers to a page in the instruction manual.
Press to confirm. The default settings (settings when the menu is reset)
Display panel
1
b c d e f g h i j l n
2 3 4 5 6 7 8 9 0 a
mk
No. Display Name Description See:
1 Battery symbol Lit when the weight reading is stable. Also lit when the option currently set in menu setting is displayed. ^ P.33
2 Zero tracking symbol Lit when the zero tracking function is set ON. ^ P.71
3 Weight symbol This symbol is lit during calibration. ^ P.57 ^ P.62
4 Easy setting indicator Indicates what level the response and stability are currently set to. ^ P.78
5 Pouring symbol Lit when the pouring mode is set. ^ P.77
6 Formulation symbol Lit during mixing measurement (formulation) operations. ^ P.96
7 Menu lock symbol Lit while the menu is locked. ^ P.52
8 Menu operation key symbol During menu operation, indicates which of the menu operation keys can be used. ^ P.47
No. Display Name Description See:
9 Auto print symbol Lit when the Auto Print function is set. ^ P.108
0 Win symbol Lit when the WindowsDirect communication function has been set. ^ P.112
a Communication symbol Indicates that data is being exchanged with an external device. -
b Comparator symbol When the comparator function (Checkweighing) has been set, indicates the comparison judgment. ^ P.102
c Stability mark Lit when the weight reading is stable. Lit when the option currently set in menu setting is displayed.
^ P.48^ P.79
d Minus symbol Lit when the weight reading is negative. -
e Ready symbolLit during the standby mode (TX series only). Also, during weighing, lit to indicate the ready to weigh status, for example when using the formulation function.
^ P.43^ P.96
f Number symbol Lit when it is possible to enter numerical values. ^ P.49
g Hold symbol Lit when a value that is not the real-time weight reading (for example the indication of the unit weight in piece counting) is displayed.
^ P.90^ P.95
h Net weight symbolIndicates that the weight reading displayed in mixing measurement (formulation) is the net weight of the current component with the weight of the container and prior components. Also indicates that a measuring operation is in progress.
^ P.97
i Gross weight symbolIndicates that the weight reading displayed in mixing measurement (formulation) is the total weight of all of the components of the mixture with the weight of the container subtracted.
^ P.97
j Item number indication Shows the item number in the piece counting mode. ^ P.90
k Inverse triangle symbolWhen this symbol is lit when changing the position of the decimal point in the conversion factor with the user-specified units, numerical values can be entered without a decimal point.
^ P.50
l Piece counting symbol Lit while the piece counting mode is in effect. ^ P.90
mSpecific percentage weighing symbol
Lit when the specific percentage reference has been set for percentage weighing. ^ P.94
n Percentage weighing symbol Lit during percentage weighing. ^ P.95
Operation keysNo. Key Press Once and Release Press and Hold for About 3 Seconds
1 [BREAK] Switches between the operation and standby modes -
2 [CAL] Performs calibration Enters the calibration menu
3 [O/T] Tares the balance (setting it to zero) Opens the zero / tare menu
4 [PRINT] Outputs the weight reading to a peripheral device (printer or PC) Opens the data output menu
Menu operation keysNo. Key Press Once and Release Press and Hold for About 3 Seconds
5 [MENU/ENTER] Displays the main menu Shows the menu displayed last
6 [UNIT]
In the weighing mode: Used to select the unitWhen piece counting: Displays the unit weightWhen performing percentage weighing: Displays the reference weight
•••
In the weighing mode: Opens the unit setting menuWhen piece counting: Used to select the item numberWhen performing percentage weighing: Used to select the percentage reference
•••
7 [FUNC] Switches between the weighing mode and the application function mode Selects the minimum number of displayed digits
8 [Res] The response of the display is increased. -
9 [Stb] The stability of the display is increased. -