Attain Certificate: ISO 9001: 2008 ISO 14001: 2004 GB/T 28001- 2011 UL CE ■ ■ ■ ■ Main Applications Dimensions: Telecom site Outdoor base station Floating operation site UPS ■ ■ ■ ■ ■ ■ Front terminal design, easy access for faster installation and maintainence Optimal energy density, save floor space No leakage and no acid smog spray during the operation Benefits Excellent capacity retention rate Long life float service design Excellent over discharge recovery capability Technical Parameters Normal Voltage Capacity Weight Dimensions Internal Resistance (full charged) Short- circuit Current Self Discharge @25˚C(77˚F) Operating Temperature Range Recommended Operating Temperature Recommended Charging Current Charging Voltage @25˚C(77˚F) Terminal Container Materials Capacity Affected by Temperature(C 10 ) Design Life @25°C(77˚F) 12V 150 Ah @ 10hr to 1.80V per cell @ 25˚C (77˚F) 48kg(105.82Ibs) Length: 549 mm (21.61in) Width: 110 mm (4.33in) Height: 310mm (12.20 in) 4.2mΩ 2173A Less than 4% after 30 days storage Discharge: -40˚C ~ 50˚C(-40˚F ~ 122˚F) Charge: -20˚C ~ 45˚C(-4˚F ~ 113˚F) Storage:-20˚C ~ 40˚C(-4˚F ~ 104˚F) 15˚C ~ 25˚C (59˚F ~ 77˚F) 30A Float: 2.23 V/cell Equalize: 2.35 V/cell M6 ABS/ABS V0 (Optional) 103 % @ 40˚C(104˚F) 85 % @ 0˚C(32˚F) 60 % @ -20˚C(-4˚F) 12 years V2.0 20160910EN Technical Features 6-FMX Series Front Terminal Battery 6-FMX-150B 310 110 549 54
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Attain Certi�cate:
ISO 9001: 2008
ISO 14001: 2004
GB/T 28001- 2011
UL
CE
■
■
■
■
Main Applications
Dimensions:
Telecom site
Outdoor base station
Floating operation site
UPS
■
■
■
■
■
■
Front terminal design, easy access for faster installation and maintainence
Optimal energy density, save �oor space
No leakage and no acid smog spray during the operation
Benefits
Excellent capacity retention rate
Long life �oat service design
Excellent over discharge recovery capability
Technical Parameters
Normal Voltage
Capacity
Weight
Dimensions
Internal Resistance (full charged)
Short- circuit Current
Self Discharge @25˚C(77˚F)
Operating Temperature Range
Recommended Operating Temperature
Recommended Charging Current
Charging Voltage @25˚C(77˚F)
Terminal
Container Materials
Capacity A�ected by Temperature(C10)
Design Life @25°C(77˚F)
12V
150 Ah @ 10hr to 1.80V per cell @ 25˚C (77˚F)
48kg(105.82Ibs)
Length: 549 mm (21.61in)Width: 110 mm (4.33in)Height: 310mm (12.20 in)
Constant Current Discharge Characteristics Unit: A (25ºC, 77ºF)
Constant Power Discharge Characteristics Unit: W/cell (25ºC, 77ºF)
6-FMX SeriesFront Terminal Battery6-FMX-150B
30min
158.7
150.0
142.0
135.8
131.0
1hr
88.4
85.6
83.8
80.2
77.9
2hr
53.8
53.1
52.5
51.8
51.3
3hr
38.0
37.8
37.5
37.3
37.0
4hr
30.4
30.2
30.0
29.8
29.6
5hr
25.8
25.7
25.5
25.3
25.2
6hr
22.7
22.5
22.3
22.2
22.1
8hr
18.3
18.2
18.1
18.0
17.9
10hr
15.2
15.1
15.0
14.9
14.8
12hr
12.7
12.6
12.5
12.4
12.3
30min
287.7
275.7
263.8
255.1
249.5
1hr
164.2
161.3
159.5
154.2
150.5
2hr
103.1
102.3
101.7
100.9
100.3
3hr
74.3
74.2
74.1
74.0
73.7
4hr
59.6
59.5
59.4
59.3
59.2
5hr
51.3
51.1
51.0
50.9
50.8
6hr
44.7
44.4
44.0
43.7
43.5
8hr
36.6
36.4
36.3
36.2
36.1
10hr
30.4
30.2
30.1
30.0
29.9
12hr
25.4
25.3
25.2
25.1
25.0
Declaration: This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/speci�cations are subject to modi�cation without notice. Contact CHINASHOTO for the latest information.