MOTOR:• 2 HP, 3450 RPM• 1 Phase - 200/230 Volt • 3 Phase - 200/230/460/575 Volt• Stator - Class F insulation and lead wires Nema B design• Integral thermal overload (1 phase)• Thermal sensor with leads (3 phase)• Housing-Castiron,oil-filled• Ball bearings - Upper and lower high carbon chromium steel• Power and sensor cable length - 20' (6.1 m)
Covered by US Patent Number 6,364,620.
FEATURES 1. 20' (6.1 m) power and sensor cable. 2. Cast in support legs enabling the pump to be free-standing. 3. Stainless steel lifting bail. 4. Stator - Class F insulation and lead wires Nema B design. 5. Thermal sensor protection. Oil-filled motor housing ensures
uniform heat distribution, lubricates bearings, and conducts heat for cooler running.
6. Upper and lower high carbon chromium steel ball bearings. 7. Finned motor housing and adapter for quicker heat dissipation. 8. 440C stainless steel cutter and plate hardened to Rockwell C55-60. 9. 416 stainless steel shaft and hardware resists corrosion. 10. Protective cutter ring helps to extend cutter life, 7011 model only. 11. Heavy duty motor features ball bearing construction. Class F motor
insulation is double-dipped and baked. End connections and lead wires are Class F. At maximum load, winding temperature will not exceed 250 °F (121 °C) with motor housing not submerged.
12. Viton O-ring seals.13.Heavy-dutycordsealfittings 14. Cast iron housing protected with corrosion-resistant, baked-on
(B) CONTROL PANELSTANDARD FEATURES:• NEMA 4X outdoor rating• Starting, control, and alarm circuits• Circuit breaker and rated motor contactor (single phase)• Capacitors and motor starting relay on single phase• Motor protective switch (circuit breaker/adj overloads)
and rated motor contactor (three phase) • Alternating circuit (duplex)• Automatic reversing circuit 7011 only• Audible high water alarm light• Dry auxiliary high water contact• External seal leak light• HOA switches and pilot light(s)• Terminal strips• Thermal cut-out circuit (three phase only)• Padlock hasp• UL listed
OPTIONS: Flasher for high water alarm light Manual reset of high water alarm Intrinsically safe relays Manual reversing switch Elapsed time meters For other options, consult Factory
FOR GRINDER PUMP ONLYSingle phase pump requires two capacitors and a motor starting relay factory mounted in a nema 4x starter pack.
P/N 10-0379 WGT. 7
Two capacitors and motor starting relay shipped loose to be mounted in existing panel.
P/N 10-0380 WGT. 2
THE MODEL 7011 GRINDER WILL FIT ON MYER’S RAIL P/N RWG125 (1 required) & RWGD125 (2 required) by using Zoeller’s adapter.
P/N 10-0381 WGT. 3
Hydro-O-Matic’s Hydr-O-Rail® bolts directly to Model 7011 by using base adapter. Specify when ordering
*These control boxes consist of the reversing mechanisms and capacitors (1PH units) only. They will not control pumps. Refer to Section Bforcompletesystemcontrols.Forduplexapplicationsusetwosimplexreversingcontrolboxes.(ForpumpprefixidentificationseeNews & Views 0052)
SIMPLEX REVERSING CONTROL BOXES* AUTOMATIC MANUAL
MODEL P/N WGT P/N WGTE7011 10-0352 8 10-0360 7I7011 10-0352 8 10-0360 7F7011 10-0353 6 10-0361 5J7011 10-0353 6 10-0361 5G7011 10-0353 12 Not availableBA7011 Not available Not available
C) VARIABLE LEVEL FLOAT SWITCHESINDOOR SYSTEM 3 Switches and weights P/N 10-0347
4 Switches and weights P/N 10-0348
(B) NEMA 4X Control Panels7011 Reversing Panels
Simplex Duplex
E or I7011 10-1551
24 lbs.
10-1552
35 lbs.F or J7011 10-1701 10-1700
G7011 10-3850 10-3299
BA7011 10-3851 10-3852
7012/7013 Single Directional
Simplex Duplex
E or I7012/7013 10-4166
18 lbs.
10-1755
22 lbs.F or J7012/7013 10-1097 10-1125
G7012/7013 10-1094 10-1122
BA7012/7013 10-1146 10-1168
OUTDOOR SYSTEM Switches with pipe clamps, 3 required
P/N 10-0744 20'
P/N 10-1878 35' P/N 10-1879 50'
SK3265
Fiberglass Simplexc 33-2054 24" X 48" c 33-2057 24" X 60" c 33-2060 24" X 72" c 33-2063 24" X 84" c 33-2069 24" X 96" c 33-2075 24" X 108" c 33-2078 24" X 120"
Fiberglass Duplexc 33-2108 36" X 48" c 33-2111 36" X 60" c 33-2114 36" X 72" c 33-2117 36" X 84" c 33-2123 36" X 96" c 33-2129 36" X 108" c 33-2132 36" X 120"
HDPE Simplexc 33-3735 30" X 72" c 33-3736 30" X 84" c 33-3737 30" X 96"
D) OUTDOOR BASIN, COVER AND RAIL SYSTEM PREPACKAGED SYSTEMS
Z-Rail Disconnect System for 1-1/4" pump discharges (Rail System discharge is 2" NPT male thread) Ductile Iron Constructions P/N 39-0134 With Stainless Steel Upper Rail Support P/N 39-0135 Intermediate Stabilizer Bracket for every 12' of depth. Stainless Steel P/N 39-0139
(H) CHECK VALVES 1-1/4" Cast iron NPT female P/N 30-0163
1-1/2" Cast iron NPT female P/N 30-0164
2" Cast iron NPT female P/N 30-0152
SK1330
(G) SS LIFTING CABLE(Field Installed Systems)
8 Ft. P/N 39-0031
12 Ft. P/N 39-0032
16 Ft. P/N 39-0033
20 Ft. P/N 39-0034
24 Ft. P/N 39-0035
FEMALE THREADSBOTH ENDS
TO CONTROL
30
36
PUMPS ROTATED 90° TO SHOW FEATURES
OFF
ON
ALARMOVERRIDE
PUMPS NOTINCLUDED SK1335
(E) JUNCTION BOXES - TYPE 4XSIMPLEX 5 Holes with seals for (1) power cord, (1)sensorcord,(3)floatswitchcords. P/N 10-0331 3-floatsystem DUPLEX 8 Holes with seals for (2) power cords, (2)sensorcords,(3or4)floatswitchcords. P/N 10-03323-floatsystem P/N 10-04214-floatsystem