DynaFlowis available for following sizes: Size metering element Size vacuum jacket Overall height 1” 6” 1100mm (43,5”) 1 ½” 8” 1100mm (43,5”) 2” 8” 1100mm (43,5”) Dispense Inlet Return D F Inlet Dispens e Return M
2

M D F D F Inlet Dispense - Chart Industriesfiles.chartindustries.com/dynaflow 3000 BR2014-05 V1_0 - ds A3.pdf · • No manual setting needed, eliminates chance for fraud • Consistant

Dec 02, 2018

Download

Documents

duongtram
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: M D F D F Inlet Dispense - Chart Industriesfiles.chartindustries.com/dynaflow 3000 BR2014-05 V1_0 - ds A3.pdf · • No manual setting needed, eliminates chance for fraud • Consistant

DynaFlow™ is available for following sizes:Size metering element Size vacuum jacket Overall height1” 6” 1100mm (43,5”)1 ½” 8” 1100mm (43,5”)2” 8” 1100mm (43,5”)

DispenseInlet

Return

D

Inlet Dispense

ReturnF

M

DispenseInlet

Return

D

Inlet Dispense

ReturnF

M

Page 2: M D F D F Inlet Dispense - Chart Industriesfiles.chartindustries.com/dynaflow 3000 BR2014-05 V1_0 - ds A3.pdf · • No manual setting needed, eliminates chance for fraud • Consistant

Features Advantages/Benefi tsFeature available in

following application:Dispenser IMC Ship-Filling Transport Truck-Filling

• Real-time dynamic density measurement

• Automatically corrects for LNG- composition change• No manual setting needed, eliminates chance for fraud• Consistant accuracy over a wide range of conditions• As accurate, as the Coriolis meters on the market

• • • • •

• No moving parts • No need to replace metering section during the whole lifetime of the equipment• Reduce lifetime cost • Long term stability

• • • • •• Permanently submerged metering section

• No pre cooling needed• Allows immediate delivery and measurement • Dramatically reduce recirculation time o Shorter start up time o Startphase in less than a minute• Shorter overall delivery time• Allowed minimum measured quantity is reduced

• • • • •

• No diversion of metered fl ow • No bypass after the fl ow meter• No problems with W&M• No inaccuracy caused by a leaking valve etc.• 100% compliant to all codes (OIML, MID, NTEP, …)

• • • • •• Super insulated vacuum jacketed assembly

• Excellent heat management, minimized energy and product loses• Improves dispensing starts

• • • • •• Accuracy • Overall system accuracy meets code

requirements to industry leading minimum measured quantities (MMQ)• Meter accuracy is better than +/- 0,25%

• • • • •• New state of the art fl ow processor and system controller type Flowcom 3000

• Integrated type approved datalogger to store the measuring data. No ticket printer needed• SD-card slot for collecting the data• Intuitive operation with softkey interface• The Multi-CPU-Design allows changes in application software without direct impact on type approvals• 4 digital inputs, 5 digital outputs • Pulse outputs, allows for connecting to fuel management systems

• • • • •

• Different type approvals available

• European Type approval based on MID • (Measurements Instruments Directive) • US-Type approval, NTEP• Measurement China accepted • Compliance with Measurement Canada under the terms and conditions• Others are in preparation (Australia …)

• • • • •

• Soft start and stop of metering • Improves the system accuracy dramatically• Accurate metering from the beginning till the end • Lower allowed minimum delivery quantity• Minimizes inconvenient restarts caused by unstable conditions at the start of delivery• Eliminates “ghost fl ows” at the end of the delivery, caused by pressure spikes

• – – – –

• Precise factory calibration and liquid test

• No need for on-site calibration during commissioning = saving your time and cost• The cold shock of system fi nds nuisances leaks prior to site installation

• • – o –• Multiple pump protection functions “PumpSmart”

• Protects your pump against failures, caused by wrong handling• Pump operation lock-out if not properly cool down• Pump operation shut-down if tank runs dry• Hour counter with service warning (temporarily locks out pump if ignored)

– – o • o