STOCK:002130 LV&MV Power cable accessories LV&MV Power cable accessories PRODUCT CATALOGUE SHENZHEN WOER HEAT-SHRINKABLE MATERIAL CO.,LTD Woer mansion,North Lanjing Rd,Pingshan,Shenzhen P.R.CHINA Tel:86-755-28299160,26620597 Fax:86-755-28299160 Email:[email protected]Http://www.woer.com Important Notice While Woer has made every effort to ensure the accuracy of the information in this catalog, Woer does not guarantee that it is errorless. Nor does Woer make any other warranty or guarantee that the information is accurate, reliable or current. Before using our products, you must evaluate them and determine if they are suitable for your intended application. Woer reserves all the rights to make any adjustments to the information contained at any time without notice.
39
Embed
LV&MV Power cable accessoriesenterkom.by/f/termousazhivayemyye_vysokovoltnyye_trubki_i_aksess… · STOCK:002130 LV&MV Power cable accessories PRODUCT CATALOGUE SHENZHEN WOER HEAT-SHRINKABLE
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
STOCK:002130
LV&MV Power cable accessoriesLV&MV Power cable accessories
RSFRNH-BTM Medium Voltage Cross-linked Polyolefin Bus Bar Tubing
WRSXP Heat Shrink Repair Sleeve
Heat Shrink Moulded Shapes
WRSZT Heat Shrink Breakout
WRSZT6 Heat Shrink 6-Core Breakout
WRSFM Heat Shrink Cable End Cap
AC Heat Shrink Anode Cap
WRSSQ
WRSRS
Heat Shrink Anti-tracking Rain Shed
Heat Shrink Anti-tracking Rain Shed
WRSJX Heat Shrink Right Angle/In-line Bushing Boot
WRSLT Heat Shrink Cable Entry Seal
Heat Shrink WRSKT 2-Core Clip-on Breakout
WRSY Heat Shrink Y-type Tube
Contents
52
54
51
53
55
Z11 Heat Shrink Cable Straight Boot
W11 Heat Shrink Right Angled Boot
C21 Heat Shrink 2-Way Outlet Shapes
C31 Heat Shrink 3-Way Outlet Shapes
C41 Heat Shrink 4-Way Outlet Shapes
RSTHeat Shrink Termination for LV Cables
The terminations are designed for 1-, 2-, 3-, 4- and 5-core cables with or without armour. The
terminations are also applicable to 3+1, 4+1 and 3+2 cables.
The cable crutch is sealed by a breakout inner coated with adhesive. Heat shrink insulation tubes seal
between the cable lug and the bottom end of the core insulation. For single core cables only an insulation
tube is needed. All materials are resistant to UV and weathering.
Note:
Solderless earth connection system for armoured cables is available on request.
Lugs and other accessories need to be ordered separately.
Terminations and components for other cable types are available on request.
Termination kit for 4-core cables
0.6/1(1.2)kV 4, 5, 3, 2, 1
4-6
10-16
25-50
70-120
150-240
300-400
0.6/1kVRST-4(5,3,2,1)/(-1)
0.6/1kVRST-4(5,3,2,1)/0
0.6/1kVRST-4(5,3,2,1)/1
0.6/1kVRST-4(5,3,2,1)/2
0.6/1kVRST-4(5,3,2,1)/3
0.6/1kVRST-4(5,3,2,1)/4
Voltage Cores 2Cross Section/mm
Selection Table
Kit No.
87 Product Catalogue www.woer.com
WOER Electrical Power Product
Heat Shrink Cable Accessories
Heat shrink cable accessories are made of rubber/plastic composites.
After exposure to radiation, the semi-finished product is heated and
stretched to expand its dimension. It is then rapidly cooled in order to keep
its shape. When installing, the cable accessories will shrink back down to
the original dimensions by applying heating because of their “shape
memory effect”. Therefore, the heat shrink cable accessories will provide
excellent insulation, sealing and mechanical protection for power cables.
RSNY-1Indoor termination for screened, 1-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
The indoor termination is designed for screened single core polymeric insulated
MV cables up to 35kV.
Yellow stress relief mastic is laid around the end of the screen cut. Stress
control tube, together with stress relief mastic, is used to smooth out the
electrical field at the cable screen end. Anti-tracking insulation tube and sealing
tube seal between the end of the oversheath and the cable lug. Anti-tracking
rain sheds increase surface creepage distance to ensure safety.
Solderles earth connection is supplied with the standard kit. For soldering earth
connection, please order separately.
Note:1.Lugs need to be ordered separately.2.RSNY-1 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSNY-1/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSNY-1/1-X.
Nominal voltageU /U(U ) 0 m
2Cross section (mm ) Kit No.Dimensions(mm)
L D
No. of skirts
3.6 / 6(7.2)kV
6 / 10(12)
6.35 / 11
8.7 / 15(17.5)
kV
(12)kV
kV
12 / 20(24)
12.7 / 22
kV
(24)kV
18 / 30(36)
19 / 33
kV
(36)kV
20.8 / 36(42)
26 / 35
kV
(42)kV
25-50
70-120
150-240
300-400
500-630
800-1000
1200
25-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
50
70-120
150-240
300-400
500-630
800-1000
1200
6 RSNY-1/1
6 RSNY-1/2
6 RSNY-1/3
6 RSNY-1/4
6 RSNY-1/5
6 RSNY-1/6
6 RSNY-1/7
kV
kV
kV
kV
kV
kV
kV
10 RSNY-1/1
10 RSNY-1/2
10 RSNY-1/3
10 RSNY-1/4
10 RSNY-1/5
10 RSNY-1/6
10 RSNY-1/7
kV
kV
kV
kV
kV
kV
kV
20 RSNY-1/1
20 RSNY-1/2
20 RSNY-1/3
20 RSNY-1/4
20 RSNY-1/5
20 RSNY-1/6
20 RSNY-1/7
kV
kV
kV
kV
kV
kV
kV
30 RSNY-1/1
30 RSNY-1/2
30 RSNY-1/3
30 RSNY-1/4
30 RSNY-1/5
30 RSNY-1/6
30 RSNY-1/7
kV
kV
kV
kV
kV
kV
kV
35 RSNY-1/1
35 RSNY-1/2
35 RSNY-1/3
35 RSNY-1/4
35 RSNY-1/5
35 RSNY-1/6
35 RSNY-1/7
kV
kV
kV
kV
kV
kV
kV
0
0
2
4
4
105
105
105
105
140
140
140
800
800
800
800
800
105
105
105
105
140
140
140
105
105
105
140
140
140
140
105
105
140
140
140
140
140
140
140
140
140
140
140
140
WOER Electrical Power Product
109 Product Catalogue www.woer.com
RSNY/RSWYHeat Shrink Termination For MV Cables Up To 42kV
Design of Termination
Woer provides a universal system for indoor and outdoor
terminations for paper or polymeric insulated cables.
1. Electrical Stress Control
Yellow stress relief mastic is laid around the end of the screen cut.
Stress control tube, together with stress mastic, is used to
smooth out the electrical field at the cable end.
2. Excellent Anti-tracking Properties
Anti-tracking insulation tubes and rain sheds have an excellent
tracking and erosion resistance. This ensures Woer terminations
Durable sealing is achieved by hot-melted adhesive on the inside
of sealing tube and anti-tracking insulation tube. In case of 3-core
cables, the crutch area is sealed and protected with an adhesive-
coated breakout which is installed over the cores and the end of
oversheath.
5. Earth Connection
Either soldering or solderless earth connection is available to
connect metal screen or armour to ground. For cables with wire
screen, copper wires are imbedded in the sealing mastic to prevent
any corrosion by moisture sealing.
relief
RSNY-3Indoor termination for screened, 3-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
The indoor termination is designed for screened three core polymeric
insulated MV cables up to 35kV.
Yellow stress relief mastic is laid around the end of the screen cut.
Stress control tube, together with stress relief mastic, is used to
smooth out the electrical field at the cable screen end. All phase cores
are covered with anti-tracking insulation tube and sealing tube. Anti-
tracking rain sheds increase surface creepage distance to ensure
safety. The crutch area is sealed and protected with an adhesive-
coated breakout which is installed over the cores and the end of
oversheath. In case of 6kV and 10kV cables, a 3-core rain shed is
supplied in the kit.
Solderless earth connection is supplied with the standard kit. For
soldering earth connection, please order separately.
Note:1.Lugs need to be ordered separately.2.RSNY-3 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSNY-3/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSNY-3/1-X.
Nominal voltageU /U(U ) 0 m
Cross section2 (mm ) Kit No.
Dimensions(mm)
L D
No. of skirts
3.6 / 6(7.2) Vk
6 / 10(12)
6.35 / 11(12)
8.7 / 15( )
kV
kV
kV17.5
12 / 20(24)
12.7 / 22(24)
kV
kV
18 / 30(36)
19 / 33(36)
kV
kV
20.8 / 36(42)
26 / 35(42)
kV
kV
25-50
70-120
150-240
300-400
500-630
25-50
70-120
150-240
300-400
500-630
35-50
70-120
150-240
300-400
500-630
35-50
70-120
150-240
300-400
500-630
50
70-120
150-240
300-400
500-630
6 RSNY-3/1
6 RSNY-3/2
6 RSNY-3/3
6 RSNY-3/4
6 RSNY-3/5
kV
kV
kV
kV
kV
10 RSNY-3/1
10 RSNY-3/2
10 RSNY-3/3
10 RSNY-3/4
10 RSNY-3/5
kV
kV
kV
kV
kV
20 RSNY-3/1
20 RSNY-3/2
20 RSNY-3/3
20 RSNY-3/4
20 RSNY-3/5
kV
kV
kV
kV
kV
30 RSNY-3/1
30 RSNY-3/2
30 RSNY-3/3
30 RSNY-3/4
30 RSNY-3/5
kV
kV
kV
kV
kV
35 RSNY-3/1
35 RSNY-3/2
35 RSNY-3/3
35 RSNY-3/4
35 RSNY-3/5
kV
kV
kV
kV
kV
0
0
6
12
12
105
105
105
105
140
750
750
900
1100
1100
105
105
105
105
140
105
105
105
140
140
105
105
140
140
140
140
140
140
140
140
WOER Electrical Power Product
1211 Product Catalogue www.woer.com
RSWY-1Outdoor termination for screened, 1-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
The outdoor termination is designed for screened single core polymeric
insulated MV cables up to 35kV.
Yellow stress relief mastic is laid around the end of the screen cut. Stress
control tube, together with stress relief mastic, is used to smooth out the
electrical field at the cable screen end. Anti-tracking insulation tube and sealing
tube seal between the end of the oversheath and the cable lug. Anti-tracking
rain sheds increase surface creepage distance to ensure safety.
Solderless earth connection is supplied with the standard kit. For soldering
earth connection, please order separately.
Note:1.Lugs need to be ordered separately.2.RSWY-1 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSWY-1/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSWY-1/1-X.
Nominal voltageU /U(U ) 0 m
2Cross section (mm ) Kit No.Dimensions(mm)
L DNo. of skirts
25-50
70-120
150-240
300-400
500-630
800-1000
1200
25-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
50
70-120
150-240
300-400
500-630
800-1000
1200
6 RSWY-1/1
6 RSWY-1/2
6 RSWY-1/3
6 RSWY-1/4
6 RSWY-1/5
6 RSWY-1/6
6 RSWY-1/7
kV
kV
kV
kV
kV
kV
kV
10 RSWY-1/1
10 RSWY-1/2
10 RSWY-1/3
10 RSWY-1/4
10 RSWY-1/5
10 RSWY-1/6
10 RSWY-1/7
kV
kV
kV
kV
kV
kV
kV
20 RSWY-1/1
20 RSWY-1/2
20 RSWY-1/3
20 RSWY-1/4
20 RSWY-1/5
20 RSWY-1/6
20 RSWY-1/7
kV
kV
kV
kV
kV
kV
kV
30 RSWY-1/1
30 RSWY-1/2
30 RSWY-1/3
30 RSWY-1/4
30 RSWY-1/5
30 RSWY-1/6
30 RSWY-1/7
kV
kV
kV
kV
kV
kV
kV
35 RSWY-1/1
35 RSWY-1/2
35 RSWY-1/3
35 RSWY-1/4
35 RSWY-1/5
35 RSWY-1/6
35 RSWY-1/7
kV
kV
kV
kV
kV
kV
kV
3
3
4
6
6
105
105
105
105
140
140
140
800
800
800
800
800
105
105
105
105
140
140
140
105
105
105
140
140
140
140
105
105
140
140
140
140
140
140
140
140
140
140
140
140
3.6 / 6(7.2) Vk
6 / 10(12)
6.35 / 11(12)
8.7 / 15( )
kV
kV
kV17.5
12 / 20(24)
12.7 / 22(24)
kV
kV
18 / 30(36)
19 / 33(36)
kV
kV
20.8 / 36(42)
26 / 35(42)
kV
kV
RSJHeat Shrink Joints for LV Cables
The joints are designed for 1-, 2-, 3-, 4- and 5-core cables with or without armour. The joints are also
applicable to 3+1, 4+1 and 3+2 cables.
The connectors are insulated and sealed with adhesive coated insulation tubes. The outer tube provides
mechanical protection and chemical resistance as expected from cable oversheath. All joints are designed
to allow crossing of cable cores.
Note:
Joints and components for other cable types are available on request.
Solderless earth connection system for armoured cables is available on request.
Connectors and other accessories need to be ordered separately.
Joint Kit for LV 4-Core Cable
4-6
10-16
25-50
70-120
150-240
300-400
0.6/1kVRSJ-4(5,3,2,1)/(-1)
0.6/1kVRSJ-4(5,3,2,1)/0
0.6/1kVRSJ-4(5,3,2,1)/1
0.6/1kVRSJ-4(5,3,2,1)/2
0.6/1kVRSJ-4(5,3,2,1)/3
0.6/1kVRSJ-4(5,3,2,1)/4
0.6/1 kV(1.2) 4, 5, 3, 2, 1
Voltage U /U(U )0 m Cores 2Cross Section/mm Kit No.
Selection Table
WOER Electrical Power Product
1413 Product Catalogue www.woer.com
RSWY-3Outdoor termination for screened, 3-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
The outdoor termination is designed for screened three core polymeric
insulated MV cables up to 35kV.
Yellow stress relief mastic is laid around the end of the screen cut.
Stress control tube, together with stress relief mastic, is used to
smooth out the electrical field at the cable screen end. All phase cores
are covered with anti-tracking insulation tube and sealing tube. Anti-
tracking rain sheds increase surface creepage distance to ensure safety.
The crutch area is sealed and protected with an adhesive-coated
breakout which is installed over the cores and the end of oversheath. In
case of 6kV and 10kV cables, a 3-core rain shed is supplied in the kit.
Solderless earth connection is supplied with the standard kit. For
soldering earth connection, please order separately.
Note:1.Lugs need to be ordered separately.2.RSWY-3 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSWY-3/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSWY-3/1-X.
Nominal voltageU /U(U ) 0 m
Cross section2 (mm ) Kit No.
Dimensions(mm)
L D
No. of skirts
25-50
70-120
150-240
300-400
500-630
25-50
70-120
150-240
300-400
500-630
35-50
70-120
150-240
300-400
500-630
35-50
70-120
150-240
300-400
500-630
50
70-120
150-240
300-400
500-630
6 RSWY-3/1
6 RSWY-3/2
6 RSWY-3/3
6 RSWY-3/4
6 RSWY-3/5
kV
kV
kV
kV
kV
10 RSWY-3/1
10 RSWY-3/2
10 RSWY-3/3
10 RSWY-3/4
10 RSWY-3/5
kV
kV
kV
kV
kV
20 RSWY-3/1
20 RSWY-3/2
20 RSWY-3/3
20 RSWY-3/4
20 RSWY-3/5
kV
kV
kV
kV
kV
30 RSWY-3/1
30 RSWY-3/2
30 RSWY-3/3
30 RSWY-3/4
30 RSWY-3/5
kV
kV
kV
kV
kV
35 RSWY-3/1
35 RSWY-3/2
35 RSWY-3/3
35 RSWY-3/4
35 RSWY-3/5
kV
kV
kV
kV
kV
6
6
12
18
18
105
105
105
105
140
900
900
900
1100
1100
105
105
105
105
140
105
105
105
140
140
105
105
140
140
140
140
140
140
140
140
3.6 / 6(7.2) Vk
6 / 10(12)
6.35 / 11(12)
8.7 / 15( )
kV
kV
kV17.5
12 / 20(24)
12.7 / 22(24)
kV
kV
18 / 30(36)
19 / 33(36)
kV
kV
20.8 / 36(42)
26 / 35(42)
kV
kV
RSJY-1Straight joint for screened, 1-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
The joint is designed for screened single core polymeric insulated MV cables up to 35kV.
Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable
screen ends. Heat shrink insulation tube delivers consistent insulation thickness over the core insulation. Heat
shrink dual wall tube is adopted to help ensure a void-free interface between the insulation and screen.
Copper mesh wrapped around the joint area rebuilds the metallic screen. Either soldering or solderless earth
connection is available to provide screen continuity across the joint. The outer sealing and protection is
performed by an adhesive coated heat shrink tube.
Nominal voltageU /U(U ) 0 m
2Cross section (mm ) Kit No.L
Dimensions(mm)
25-50
70-120
150-240
300-400
500-630
800-1000
1200
25-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
35-50
70-120
150-240
300-400
500-630
800-1000
1200
50
70-120
150-240
300-400
500-630
800-1000
1200
6 RSJY-1/1
6 RSJY-1/2
6 RSJY-1/3
6 RSJY-1/4
6 RSJY-1/5
6 RSJY-1/6
6 RSJY-1/7
kV
kV
kV
kV
kV
kV
kV
10 RSJY-1/1
10 RSJY-1/2
10 RSJY-1/3
10 RSJY-1/4
10 RSJY-1/5
10 RSJY-1/6
10 RSJY-1/7
kV
kV
kV
kV
kV
kV
kV
20 RSJY-1/1
20 RSJY-1/2
20 RSJY-1/3
20 RSJY-1/4
20 RSJY-1/5
20 RSJY-1/6
20 RSJY-1/7
kV
kV
kV
kV
kV
kV
kV
30 RSJY-1/1
30 RSJY-1/2
30 RSJY-1/3
30 RSJY-1/4
30 RSJY-1/5
30 RSJY-1/6
30 RSJY-1/7
kV
kV
kV
kV
kV
kV
kV
35 RSJY-1/1
35 RSJY-1/2
35 RSJY-1/3
35 RSJY-1/4
35 RSJY-1/5
35 RSJY-1/6
35 RSJY-1/7
kV
kV
kV
kV
kV
kV
kV
820
820
820
820
820
820
820
820
820
820
820
820
820
820
820
820
820
1020
1020
1020
1020
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1160
1160
1160
1160
Note:1.Connectors need to be ordered separately.2.RSJY-1 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSJY-1/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSJY-1/1-X.
Selection Table
WOER Electrical Power Product
1615 Product Catalogue www.woer.com
RSJY Heat Shrink Joints For MV Cables Up To 42kV
The joints are designed for MV screened, 1-core polymeric insulated cables with or without armour. The
same design principles are used for 3-core cables.
1. Electrical stress control
Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable
screen ends.
2. Insulation and screen
Heat shrink insulation tube delivers consistent insulation thickness to meet or exceed that of the cable.
Heat shrink semi-conductive /insulation dual layer tube is also adopted to help ensure a void-free
interface between the insulation and screen.
3. Metallic shielding
Copper mesh wrapped around the joint area rebuilds the metallic screen. Either soldering or solderless
earth connection is available to provide screen continuity across the joint.
4. Outer sealing and protection
The outer sealing and protection is performed by an adhesive coated, heat shrink tube. It provides
mechanical protection and chemical resistance as expected from cable oversheath.
Design of Joint
3.6 / 6(7.2) Vk
6 / 10(12)
6.35 / 11(12)
8.7 / 15( )
kV
kV
kV17.5
12 / 20(24)
12.7 / 22(24)
kV
kV
18 / 30(36)
19 / 33(36)
kV
kV
20.8 / 36(42)
26 / 35(42)
kV
kV
WRSJGHeat Shrink Anti-tracking Insulation Tube
Manufactured from cross linked polyolefin, inner coated
with adhesive at one end
Protecting against accidental flashover
Used in medium voltage cable terminations up to 42 kV
Shrink temperature: start at 90℃, and fully recovered at
130℃
Color: red
Product No.
Inner Diameter
As Supplied (Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.2mm)/mm
Standard Cut Length /mm
Standard Continuous Length
(m/roll)
10kV WRSJG-30/12
10kV WRSJG-35/14
10kV WRSJG-38/17
10kV WRSJG-50/22
10kV WRSJG-55/24
10kV WRSJG-70/29
10kV WRSJG-80/35
20kV WRSJG Series
20kV WRSJG-38/15
20kV WRSJG-55/24
20kV WRSJG-80/35
20kV WRSJG-35/14
20kV WRSJG-50/19
20kV WRSJG-60/26
20kV WRSJG-70/29
20kV WRSJG-89/41
30
35
38
50
35
38
50
55
55
60
70
70
80
80
89
12
14
17
22
24
29
35
15
24
35
14
19
26
29
41
2.2
2.3
3.0
2.3
3.0
2.4
3.0
3.2
3.2
3.2
3.2
3.2
3.2
3.5
3.2
600-1200 25
600-1200 25
600-1200 25
25
25
600-1200 25
25
15
15
15
15
15
15
600-1200
15
15
600-1200
600-1200
600-1200
600-1200
600-1200
600-1200
600-1200
600-1200
600-1200
600-1200
Selection Table
WOER Electrical Power Product
1817 Product Catalogue www.woer.com
RSJY-3Straight joint for screened, 3-core polymeric insulated cables6kV, 10kV, 20kV, 30kV and 35kV
Note:1.Connectors need to be ordered separately.2.RSJY-3 is for cables with copper wire screen without armour.3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix –WA. For example, 6kVRSJY-3/1-WA.
•For cables with copper tape screen without armourwire, add suffix –X. For example, 6kVRSJY-3/1-X.
The joint is designed for screened three core polymeric insulated MV cables up to 35kV.
Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable
screen ends.
Copper mesh wrapped around the joint area rebuilds the metallic screen. Either soldering or solderless earth
connection is available to provide screen continuity across the joint. The outer sealing and protection is
performed by an adhesive coated heat shrink tube.
Heat shrink insulation tube delivers consistent insulation thickness over the core insulation.
Heat shrink dual wall tube is adopted to help ensure a void-free interface between the insulation and screen.
The red inner layer is made of insulation material to provide good
insulation
The black outer layer is made of semi-conductive material to
provide electrical shielding
Suitable for applications in medium voltage cable joints up to 42 kV
Shrink temperature: start at 90℃, and fully recovered at 130℃
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Volume Resistivity
Dielectric Strength
Longitudinal Shrinkage
Eccentricity
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60093
IEC 60243
ASTM-D-2671
ASTM-D-2671
≥12MPa
≥400%
≥10MPa (130℃,168 hrs)
≥320% (130℃,168hrs)
14≥1×10 Ω·cm
≥25kV/mm
≤10%
≤30%
Water Absorption ISO 62 ≤0.5%
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Volume Resistivity
Longitudinal Shrinkage
Eccentricity
Water Absorption
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60093
ASTM-D-2671
ASTM-D-2671
ISO 62
≥10MPa
≥300%
≥8MPa (130℃,168 hrs)
≥240% (130℃,168hrs)
2 410 ~10 Ω·cm
≤10%
≤30%
≤0.5%
Product No.Inner Diameter
As Supplied(Min) /mm
Total(±0.3)Red layer
(±0.2)Black layer
(±0.1)After Recovered
(Max) /mm
After Recovered Wall Thickness /mm
Standard Length /mm
WDWT-30/12
WDWT-35/13
WDWT-45/16
WDWT-50/16
WDWT-60/20
WDWT-90/29
WDWT-55/20
WDWT-65/26
WDWT-100/37
WDWT-85/29
WDWT-120/45
30
35
45
50
60
90
55
65
100
85
120
12
13
16
16
20
29
20
26
37
29
45
5.8 5.0 0.8
5.8 5.0 0.8
5.8 5.0 0.8
5.8 5.0 0.8
5.8 5.0 0.8
7.3 6.5 0.8
5.8 5.0 0.8
5.8 5.0 0.8
7.3 6.5 0.8
7.3 6.5 0.8
7.3 6.5 0.8
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
Selection Table
Inner Insulation Layer(Red)
Outer Semi-conductive Layer(Black)
WOER Electrical Power Product
2019 Product Catalogue www.woer.com
Technical Data
Product No.
Inner Diameter
As Supplied (Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.2mm)/mm
Standard Cut Length /mm
Standard Continuous Length
(m/roll)
30kV WRSJG Series
30kV WRSJG-50/19
30kV WRSJG-55/24
30kV WRSJG-60/26
30kV WRSJG-70/29
30kV WRSJG-80/35
30kV WRSJG-89/41
30kV WRSJG-100/45
35kV WRSJG-55/24
35kV WRSJG-60/26
35kV WRSJG-70/29
35kV WRSJG Series
35kV WRSJG-80/35
35kV WRSJG-100/45
35kV WRSJG-89/41
50
70
55
60
80
70
89
100
80
89
100
55
60
19
24
26
29
35
41
45
24
26
29
35
45
41
3.2
3.0
3.2
3.2
3.5
3.2
3.5
3.2
3.2
3.5
3.5
3.2
3.2
15
600-1200 25
600-1200 15
15
600-1200 15
15
600-1200 15
15
600-1200 15
600-1200 15
600-1200 15
600-1200
600-1200
15
15
600-1200
600-1200
600-1200
600-1200
Tensile Strength
Elongation at Break after Aging
Dielectric Strength
Tracking Resistance
Volume Resistivity
Dielectric Constant
Water Absorption
Copper Corrosion
Low Temperature Flexibility
Tensile Strength after Aging
Elongation at Break
Property Test Method Standard Value
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
IEC 60587
IEC 60093
IEC 60250
ISO 62
ASTM-D-2671
ASTM-D-2671
≥10MPa
≥300%
≥8MPa (130℃,168 hrs)
≥230% (130℃,168 hrs)
≥25kV/mm
1A 3.5
14≥1×10 Ω·cm
≤3.0
≤0.5%
No corrosion (130℃,168 hrs)
No cracking (-40℃, 4 hrs)
WRSHGHeat Shrink Protective Tube
Manufactured from cross linked polyolefin
Providing outer sealing protection for power cable joints up to
42kV
Used in 1kV cable joints and terminations to provide electrical
insulation (Φ50 and below)
Outstanding abrasion and chemical resistance
Inner coated with adhesive at both ends. Tubes inner coated with
adhesive at full length are available upon customer request.
Shrink temperature: start at 90℃, and fully recovered at 130℃
Color: black, red, yellow, blue, green(Φ50 and below); black
only(above Φ50 ). Other colors are available upon customer
request.
Selection Table
Product No.
Inner Diameter
As Supplied (Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.2mm)/mm
Standard Cut Length /mm
Standard Continuous Length
(m/roll)
WRSHG-50/22
WRSHG-60/22
WRSHG-80/29
WRSHG-85/29
WRSHG-100/38
WRSHG-120/45
WRSHG-140/49
WRSHG-160/56
WRSHG-180/61
WRSHG-290/100
WRSHG-200/70
WRSHG-350/152
WRSHG-225/70
WRSHG-400/171
WRSHG-240/89
WRSHG-450/210
WRSHG-500/210
WRSHG-600/210
50
60
80
85
100
120
140
160
180
290
200
350
225
400
240
450
500
600
22
22
29
29
38
45
49
56
61
100
70
152
70
171
89
210
210
210
2.6±0.2
2.6±0.2
2.9±0.2
2.9±0.2
3.1±0.2
3.1±0.2
3.6±0.3
3.6±0.3
3.9±0.3
4.4±0.3
4.4±0.3
3.0±0.4
4.4±0.3
3.0±0.4
4.4±0.3
3.2±0.4
3.2±0.4
3.9±0.4
25800-1200
25800-1200
25800-1200
25800-1200
15800-1200
15800-1200
15800-1200
15800-1200
-10/5WRSHG
WRSHG-15/6
WRSHG-20/8
WRSHG-30/11
WRSHG-35/13
WRSHG-45/17
WRSHG-40/17
10
15
20
30
35
45
40
5
6
8
11
13
17
17
1.3±0.2
1.2±0.2
1.7±0.2
1.8±0.2
2.0±0.2
2.2±0.2
2.2±0.2
25275-1000
25275-1000
25275-1000
25275-1000
25275-1000
25
25
275-1000
275-1000
15800-1200
15800-1200
15800-1200
15800-1200
15800-1200
15800-1200
15800-1200
15800-1200
15
15
800-1200
800-1200
WOER Electrical Power Product
2221 Product Catalogue www.woer.com
WRSHJGHeat Shrink Insulation Tube
Manufactured from cross linked polyolefin
Used in MV cable joints to provide electrical insulation up to 42 kV
Shrink temperature: start at 90℃, and fully recovered at 130℃
Color: red
Product No.
Inner Diameter
As Supplied (Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.3)/mm Standard Length /mm
WRSHJG-30/12
WRSHJG-35/14
WRSHJG-40/17
WRSHJG-45/17
WRSHJG-50/22
WRSHJG-55/25
WRSHJG-55/22
WRSHJG-60/25
WRSHJG-70/29
WRSHJG-100/38
WRSHJG-65/25
WRSHJG-85/38
30
35
40
45
50
55
55
60
70
100
65
85
120
80
WRSHJG-120/41
WRSHJG-80/35
12
14
17
17
22
25
22
25
29
38
25
38
41
35
3.6
3.8
3.8
3.8
3.8
3.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
500-850
Technical Data
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Dielectric Strength
Volume Resistivity
Dielectric Constant
Longitudinal Shrinkage
Eccentricity
Water Absorption
Copper Corrosion
Low Temperature Flexibility
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
ASTM-D-2303
ASTM-D-150
ASTM-D-2671
ASTM-D-2671
ISO 62
ASTM-D-2671
ASTM-D-2671
≥12MPa
≥400%
≥10MPa (130℃,168 hrs)
≥250% (130℃,168 hrs)
≥25kV/mm
14≥1×10 Ω·cm
≤3.0
≤10%
≤30%
≤0.5%
No corrosion (130℃,168 hrs)
No cracking (-40℃, 4 hrs)
Selection Table
SBRSM Medium Wall Adhesive Lined Heat Shrinkable Tubing
10.2/3.0
16.0/5.0
19.1/5.6
25.0/8.0
28.0 /6.0
28.0 /9.0
35.0/10.2
38.1 /12.0
43.2 /12.7
52.1 /16.0
63.0/19.0
75.0/22
85.0/25.0
95.0/29.0
115.0/43.0
140.0/42.0
0.35±0.10
0.40±0.10
0.45±0.10
0.45±0.10
0.65±0.10
0.50±0.10
0.50±0.10
0.50±0.10
0.50±0.10
0.50±0.15
0.50±0.15
0.50±0.15
0.50±0.15
0.60±0.20
0.60±0.20
0.60±0.20
1.75±0.25
1.90±0.25
2.45±0.25
2.45±0.25
3.10±0.30
2.60±0.25
2.70±0.25
2.70±0.25
2.70±0.25
2.80±0.30
3.00±0.30
3.00±0.30
3.30±0.30
3.70±0.35
3.70±0.35
3.70±0.35
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
2 .0±0.20
2 .0±0.20
2 .5±0.20
2 .0±0.20
2 .2±0.20
2 .2±0.20
2 .2±0.20
2 .3±0.25
2 .5±0.25
2 .6±0.25
2 .8±0.30
3 .1±0.30
3 .1±0.30
3 .1±0.30
1 .4±0.20
1 .5±0.20
3 .0
5 .0
5 .6
8.0
6.0
9.0
10.2
1 2.0
12.7
1 6.0
1 9.0
2 2.0
2 5.0
2 9.0
3 4.0
4 2.0
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≤
≥10.2
≥16.0
≥19.1
≥25.0
≥28.0
≥28.0
≥35.0
≥38.1
≥43.2
≥52.1
≥63.0
≥75.0
≥85.0
≥95.0
≥115.0
≥140.0
Selection Table
Technical Data
Property Test Method Stantard
Tensile Strength(Mpa)
Elongation(%)
3Density(g/cm )
Longitudinal change(%)
Elongation after aging(%)
Heat shock
Dielectric strength(kv/mm)
Volume resistivity(Ω·cm)
Water absorption(%)
ASTM D2671
ASTM D2671
ASTM D792
UL 224
UL224 158℃X168hrs
UL224 225℃X4hrs
IEC 243
IEC 93
ASTM-D570
≥10.4
≥300
1.2
≤±10
≥200
No cracking
≥20
14≥10
≤0.5
Hot Melt Adhesive Property
Property Test Method
Water Absorption ASTM D570 ≤0.2%
Sofening Point ASTM E28 95℃
Peel Strength(PE) ASTM D 1000 120N/25mm
Peel Strength(AL) ASTM D 1000 80N/25mm
Stantard
As Supplied
Internal Diameter
After Recovery(mm)
Out LayerWall Thickness
A LayerWall Thickness
dhesive
Standard Length(m/pc)
Size
mm Internal Diameter
Total Wall Thickness
Medium wall heat shrinkable tubing suitable for a variety of
low voltage electrical and mechanical application,where
lighter weight and greater flexibility are important.
Flame retardantSeals and protects cable splices and terminationsHigh resistance to impact and abrasionOptional thermoplastic adhesive liner for complete
environmental protection and insulation
Continuous Operating
Temperature:-45℃ to125℃
Shrink Temperature:125℃
Note: Tubing without adhesive is available upon request
Providing effective electrical stress control for MV
cable terminations and joints up to 42 kV
Continuous operation temperature: -40℃ to 100℃
Shrink temperature: start at 90℃, and fully recovered
at 130℃
Color: black
WRSYLHeat Shrink Stress Control Tube
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Volume Resistivity
Dielectric Constant
Longitudinal Shrinkage
Eccentricity
Water Absorption
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60250
IEC 60093
ASTM-D-2671
ASTM-D-2671
ISO 62
Technical Data
Property Test Method Standard
Tensile Strength ASTM-D-638 ≥10MPa
≥300%
≥8MPa (130℃,168 hrs)
≥240% (130℃,168 hrs)
15~25
10 ≥1×10 Ω·cm
≤5%
≤30%
≤0.5%
Selection Table
Product No.
Inner Diameter
As Supplied (Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.2mm)/mm
Standard Cut Length /mm
Standard Continuous Length
(m/roll)
30kV WRSYL Series
20kV WRSYL Series
Selection Table
WOER Electrical Power Product
3029 Product Catalogue www.woer.com
Diameter As Supplied(mm) After Recovery(mm)
Standard Length(m/pc)
Size(mm)
8.0/2.0
10.2/3.0
12.0/3.0
16.0/5.0
19.1/5.6
22.0/6.0
25.4/8.0
28.0/6.0
33.0/8.0
38.1/12.0
43.2/12.7
56.0/16.0
65.0/19.0
75.0/22.0
85.0/25.0
95.0/30.0
115/34.0
130/36.0
140/42.0
160/50.0
180/58.0
1.40±0.20
1.40±0.20
1.40±0.20
1.50±0.20
1.80±0.20
2.00±0.20
2.40±0.20
2.40±0.30
2.50±0.30
2.40±0.30
2.40±0.30
2.40±0.30
2.50±0.30
2.90±0.30
2.90±0.30
3.00±0.30
3.00±0.30
3.00±0.30
3.00±0.30
3.10±0.30
3.10±0.30
0.45±0.10
0.50±0.10
0.50±0.10
0.55±0.10
0.60±0.15
0.60±0.15
0.60±0.15
0.95±0.20
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
0.80±0.15
1.85±0.25
1.90±0.25
1.90±0.25
2.15±0.25
2.40±0.25
2.60±0.25
2.60±0.25
3.30±0.35
3.30±0.35
3.30±0.35
3.30±0.35
3.30±0.35
3.30±0.40
3.70±0.40
3.70±0.40
3.80±0.40
3.80±0.40
3.80±0.40
3.80±0.40
3.90±0.40
3.90±0.40
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1
1
≥8.0
≥10.0
≥12.0
≥16.0
≥19.1
≥22.0
≥25.4
≥28.0
≥33.0
≥38.1
≥43.2
≥56.0
≥65.0
≥75.0
≥85.0
≥95.0
≥115.0
≥130.0
≥140.0
≥160.0
≥180.0
≤2.0
≤3.0
≤3.0
≤5.0
≤5.6
≤6.0
≤8.0
≤6.0
≤8.0
≤12.0
≤12.7
≤16.0
≤19.0
≤22.0
≤25.0
≤30.0
≤34.0
≤36.0
≤42.0
≤50.0
≤58.0
Selection Table
Min IDD
Out Layer T
AdhesiveThickness t
Max IDd
Total W.T T+t
Product No.
As supplied/mm
Inner Diameter Min.
Inner Diameter Max.
Wall Thickness Min.
After Recovered /mm
Standard Length /mm
Ф15
Ф32
Note: Other colors, sizes and lengths are available on request.
Ф44
Ф51
Ф102
Ф64
Ф76
15
32
44
51
102
64
76
4
6
8
10
23
13
19
2.0
2.8
3.0
3.0
4.0
4.0
4.0
300
300
300
300
300
300
300
SBRS-HRTHigh-Ratio, Thick-Wall Heat Shrink Tube
High shrink ratio up to 5.5:1
Designed to accommodate large size differences between
cables and cable connectors and backshells, thus simplifying
repair of damaged cable.
Conforms well to highly variable substrate dimensions
Inner coated with waterproofing sealant, providing
environmental sealing protection.
Provides excellent insulation and abrasion protection.
Offers toughness and durability.
RoHS compliant.
Continuous operation temperature: -55℃ to 105℃Shrink temperature: start at 90℃, and fully recovered at 130℃
Standard color: Black.
Technical Data
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
≥11.93MPa
≥532%
Volume Resistivity
Dielectric Strength
Longitudinal Shrinkage
Heat shock (225℃,4hrs)
IEC 60093
IEC 60243
UL 224
ASTM-D-2671
≥13.66MPa (150℃,168 hrs)
≥453% (150℃,168 hrs)
≥ 158.84×10 Ω·cm
≥26 kV/mm
≤10%
No cracks, flowing or dripping
Selection Table
WOER Electrical Power Product
3231 Product Catalogue www.woer.com
WRSBGHeat Shrink Semi-conductive Tube
Manufactured from cross linked semi-conductive polyolefin
Shrink temperature: start at 90℃, and fully recovered at 130℃
Color: black
Technical Data Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Volume Resistivity
Longitudinal Shrinkage
Eccentricity
Water Absorption
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60093
ASTM-D-2671
ASTM-D-2671
ISO 62
≥13MPa
≥300%
≥10.5MPa (130℃,168 hrs)
≥240% (130℃,168 hrs)
≤1× 310 Ω·cm
≤10%
≤30%
≤0.5%
Selection Table
Product No.
WRSBG-45/17
WRSBG-50/17
WRSBG-55/19
WRSBG-60/25
WRSBG-80/29
WRSBG-85/29
WRSBG-50/19
WRSBG-55/23
WRSBG-60/23
WRSBG-100/29
WRSBG-65/25
WRSBG-100/35
WRSBG-75/29
WRSBG-120/35
Inner Diameter
As SuppliedMin) /mm(
After Recovered (Max) /mm
After Recovered Wall Thickness /mm (±0.2mm)
Standard Cut Length/mm
Standard Continuous
Length (m/roll)
45
50
50
55
55
60
60
100
65
100
80
75
120
85
17
17
19
19
23
23
25
29
25
35
29
29
35
29
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.8
2.3
2.8
2.8
2.8
2.8
2.8
400-1200 25
400-1200 25
400-1200 25
400-1200 25
400-1200 25
400-1200 25
400-1200 25
400-1200 15
400-1200 25
400-1200 15
400-1200 25
400-1200 25
400-1200 15
400-1200 15
Selection Table
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Hardness (Shore A)
GB/T 1040
GB/T 1040
GB/T 1040, GB/T 7141
GB/T 1040, GB/T 7141
ISO 868
≥8MPa
≥300%
≥6.4MPa (130℃,168 hrs)
≥100% (130℃,168 hrs)
≥90
WMPGHeat Shrink Busbar Tube
Manufactured from cross linked polyolefin
Used to offer insulation protection for busbar in switchgear
and substation
Protects against short circuit and electrical leakage cause by
small animals
Reduces busbar clearance requirements
RoHS compliant
Shrink temperature: start at 70℃, and fully recovered at 125℃
Color: yellow, red, green, blue, black
Dielectric Strength
Volume Resistivity
IEC 60243
IEC 60093
≥25kV/mm
14≥1×10 Ω·cm
Dielectric Constant IEC 60250 ≤3.0
≤10%
≤10%
ASTM-D-2671
ASTM-D-2671
Longitudinal Shrinkage
Longitudinal Shrinkage
≤30%(10kV); ≤50%(35kV)
≤30%(10kV); ≤50%(35kV)
≤0.5%
≤0.5%
≥28
ASTM-D-2671
ASTM-D-2671
ISO 62
ISO 62
Eccentricity
Eccentricity
Water Absorption
Water Absorption
Flammability (Oxygen Index) ISO 4589
Technical Data
WOER Electrical Power Product
3433 Product Catalogue www.woer.com
Technical Data
Product No.
Inner Diameter
As Supplied(Min) /mm
After Recovered (Max) /mm
After Recovered Wall Thickness /mm (±0.2mm)
Nom./mmStandard Length /mm
WRSGY-30/11
WRSGY-35/12
WRSGY-40/14
WRSGY-120/45
WRSGY-40/17
WRSGY-85/29
WRSGY-50/22
WRSGY-30/12
WRSGY-100/38
30
35
40
120
40
85
50
30
100
11
12
14
45
17
29
22
12
38
1.8
2.0
3.7
3.0
2.2
2.8
3.7
3.7
3.0
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
300-1000
WRSGYHeat Shrink Oil-resistant Tube
Manufactured from cross-linked polyolefin.
Mainly used in PILC cable terminations and joints,offering oil
resistance, insulation and sealing protection.
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
ISO 62
≥10MPa
≥350%
Oil Resistance(Tensile Strength after Dipping)
Oil Resistance( Elongation at Break after Dipping)
Volume Resistivity
Dielectric Strength
Water Absorption
ASTM-D-638
ASTM-D-638
IEC 60093
IEC 60243
≥8MPa (130℃,168 hrs)
≥280% (130℃,168 hrs)
≥8MPa(70℃ cable oil, 168hrs)
≥280%(70℃ cable oil, 168hrs)
13≥1×10 Ω·cm
≥20 kV/mm
≤ 0.5%
Selection Table
20kV WMPG Series
35kV WMPG Series
As Supplied/mm
As Supplied/mm
ID (Min)
ID (Min)
Wall Thickness
Wall Thickness
ID (Max)
ID (Max)
Wall Thickness
Wall Thickness
Busbar Width (square/circular)
/mm
Busbar Width
(square)/mm
After Recovered/mm
After Recovered/mm
Standard Package(m/roll)
Standard Package(m/roll)
15/12
30
20/15
30/40
25/18
40
32/20
50
40/30
60
50/35
60/70
120/85
MAX.
60/45
70
150/105
MAX.
65/45
70/80
180/120
MAX.
70/50
80/100
210/40
MAX.
75/50
100/120
230/150
80/55
150
80/65
180
100/75
MAX.
15.0±0.8
30.0±1.0
≤8
≤15
1.30±0.30
1.90±0.50
2.50±0.20
4.00±0.30
20.0±0.8
35.0±1.0
≤10
≤18
1.30±0.30
1.90±0.50
2.50±0.20
4.00±0.30
25.0±0.8
40.0±1.0
≤13
≤20
1.30±0.30
1.90±0.50
2.50±0.20
4.00±0.30
30.0±0.8
50.0±2.0
≤15
≤25
1.30±0.30
1.90±0.50
2.50±0.20
4.00±0.30
40.0±1.0
60.0±3.0
≤20
≤30
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
50.0±2.0
65.0±3.0
120.0±4.0
210.0±5.0
≤25
≤33
≤60
≤105
1.40±0.40
1.90±0.50
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
2.80±0.30
4.00±0.30
60.0±3.0
70.0±3.0
150.0±4.0
230.0±5.0
≤30
≤35
≤75
≤115
1.40±0.40
1.90±0.50
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
2.80±0.30
4.00±0.30
65.0±3.0
75.0±3.0
180.0±5.0
250.0±5.0
≤33
≤38
≤90
≤125
1.40±0.40
1.90±0.50
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
2.80±0.30
4.00±0.30
70.0±3.0
80.0±4.0
210.0±5.0
300.0±5.0
≤35
≤40
≤105
≤150
1.40±0.40
1.90±0.50
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
2.80±0.30
4.00±0.30
75.0±3.0
100.0±4.0
230.0±5.0
≤38
≤50
≤115
1.40±0.40
1.90±0.50
1.40±0.40
2.80±0.30
4.00±0.30
2.80±0.30
80.0±3.0
120.0±4.0
≤40
≤60
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
85.0±3.0
150.0±4.0
≤43
≤75
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
100.0±4.0
180.0±5.0
≤50
≤90
1.40±0.40
1.90±0.50
2.80±0.30
4.00±0.30
25
15
25
15
25
15
25
15
25
15
25
15
25
15
25
15
25
15
25
15
25
15
25
15
20
15
25
15
20
25
15
25
15
25
15
Product No.
Product No.
20kV WMPG 15/8
35kV WMPG 30/15
20kV WMPG 20/10
35kV WMPG 35/18
20kV WMPG 25/13
35kV WMPG 40/20
20kV WMPG 30/15
35kV WMPG 50/25
20kV WMPG 40/20
35kV WMPG 60/30
20kV WMPG 50/25
35kV WMPG 65/32*
20kV WMPG 60/30
35kV WMPG 70/35
20kV WMPG 120/60
35kV WMPG 210/105*
20kV WMPG 65/33*
35kV WMPG 75/38*
20kV WMPG 150/75
35kV WMPG 230/115*
20kV WMPG 70/35
35kV WMPG 80/40
20kV WMPG 180/90
35kV WMPG 250/125*
20kV WMPG 75/38
35kV WMPG 100/50
20kV WMPG 210/105*
35kV WMPG 300/150*
20kV WMPG 80/40
35kV WMPG 120/60
20kV WMPG 230/115*
20kV WMPG 85/43*
35kV WMPG 150/75
20kV WMPG 100/50
35kV WMPG 180/90*
Note: Size with * are not standard stock items.
WOER Electrical Power Product
3635 Product Catalogue www.woer.com
10kV WMPG Series
1kV WMPG Series
As Supplied/mm
As Supplied/mm
ID (Min)
ID (Min)
Wall Thickness
Wall Thickness
ID (Max)
ID (Max)
Wall Thickness
Wall Thickness
Busbar Width
(square)/mm
Busbar Width (square/circular)
/mm
After Recovered/mm
After Recovered/mm
Standard Package(m/roll)
Standard Package(m/roll)
30
15/12
35
20/15
40
25/18
45
32/20
50
40/30
60
50/35
150
120/85
65
60/45
180
150/105
70
65/45
MAX
180/120
75
70/50
MAX
210/140
80/100
75/50
MAX
230/150
80/100
80/55
MAX
250/180
100
80/65
MAX
300/210
100/200
100/75
31.5±1.0
15.0±0.8
≤15
≤8
0.50±0.15
1.20±0.30
0.95±0.15
2.10±0.30
36.5±1.5
20.0±0.8
≤16
≤10
0.50±0.15
1.20±0.30
1.00±0.15
2.10±0.30
41.5±1.5
25.0±0.8
≤20
≤12.5
0.55±0.15
1.20±0.30
1.00±0.15
2.10±0.30
41.5±1.5
30.0±0.8
≤23
≤15
0.55±0.15
1.20±0.30
1.00±0.15
2.10±0.30
51.0±2.0
40.0±1.0
≤25
≤20
0.55±0.15
1.20±0.30
1.00±0.15
2.30±0.30
60.0±3.0
50.0±3.0
120.0±4.0
120.0±4.0
≤30
≤25
≤60
≤60
0.60±0.20
1.20±0.30
0.65±0.20
1.20±0.30
1.30±0.20
2.30±0.30
1.46±0.20
2.40±0.30
65.0±3.0
60.0±3.0
150.0±4.0
150.0±4.0
≤33
≤30
≤75
≤75
0.60±0.20
1.20±0.30
0.65±0.20
1.20±0.30
1.30±0.20
2.30±0.30
1.46±0.20
2.40±0.30
70.0±3.0
65.0±3.0
180.0±4.0
180.0±5.0
≤35
≤33
≤90
≤90
0.65±0.20
1.20±0.30
0.65±0.20
1.20±0.30
1.30±0.20
2.30±0.30
1.46±0.20
2.40±0.30
75.0±3.0
70.0±3.0
210.0±4.0
210.0±5.0
≤38
≤35
≤105
≤105
0.65±0.20
1.20±0.30
0.65±0.20
1.20±0.40
1.30±0.20
2.30±0.30
1.46±0.20
2.40±0.30
80.0±3.0
75.0±3.0
230.0±4.0
230.0±5.0
≤40
≤38
≤115
≤115
0.65±0.20
1.20±0.30
0.65±0.20
1.20±0.40
1.46±0.20
2.30±0.30
1.46±0.20
2.40±0.30
85.0±3.0
80.0±3.0
250.0±5.0
250.0±5.0
≤43
≤40
≤125
≤125
0.65±0.20
1.20±0.30
0.65±0.20
1.20±0.40
1.46±0.20
2.30±0.30
1.46±0.20
2.40±0.30
90.0±4.0
85.0±3.0
300.0±5.0
300.0±5.0
≤45
≤43
≤150
≤150
0.65±0.20
1.20±0.30
0.65±0.20
1.20±0.40
1.46±0.20
2.40±0.30
1.46±0.20
2.40±0.30
100.0±4.0
100.0±4.0
≤50
≤50
0.65±0.20
1.20±0.30
1.46±0.20
2.40±0.30
50
25
50
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
20
25
25
25
20
25
25
25
20
25
25
25
15
25
25
Product No.
Product No.
1kV WMPG 30
10kV WMPG 15/8
1kV WMPG 35
10kV WMPG 20/10
1kV WMPG 40
10kV WMPG 25/12
1kV WMPG 45
10kV WMPG 30/15
1kV WMPG 50
10kV WMPG 40/20
1kV WMPG 60
10kV WMPG 50/25
1kV WMPG 65*
10kV WMPG 60/30
1kV WMPG 120
10kV WMPG 120/60
1kV WMPG 70
10kV WMPG 65/33*
1kV WMPG 150
10kV WMPG 150/75
1kV WMPG 75*
10kV WMPG 70/35
1kV WMPG 180
10kV WMPG 180/90
1kV WMPG 80
10kV WMPG 75/38*
1kV WMPG 210*
10kV WMPG 210/105*
1kV WMPG 85*
10kV WMPG 80/40
1kV WMPG 230*
10kV WMPG 230/115*
1kV WMPG 90
10kV WMPG 85/43*
1kV WMPG 250*
10kV WMPG 250/125*
1kV WMPG 100
10kV WMPG 100/50
1kV WMPG 300*
10kV WMPG 300/150*
Manufactured from polyolefin, inner coated
with hot-melt adhesive
Providing fast and permanent repair and
sealing protection for power cables
High tensile strength, abrasion and corrosion
resistance
A corrosion proof metal channel is used to
close the sleeve during installation
Shrink temperature: start at 90℃ , and fully
recovered at 130℃
Selection Table
Product No.
Inner Diameter
As Supplied (Min)/mm
After Recovered (Max) /mm
After Recovered Wall Thickness (±0.2mm) /mm Standard Length /mm
WRSXP-30/12
WRSXP-40/14
WRSXP-50/17
WRSXP-60/23
WRSXP-65/23
WRSXP-80/35
WRSXP-85/35
WRSXP-100/35
WRSXP-120/40
WRSXP-160/50
WRSXP-150/50
WRSXP-195/70
WRSXP-240/90
WRSXP-290/115
30
40
50
60
65
80
85
100
120
160
150
195
240
290
12
14
17
23
23
35
35
35
40
50
50
70
90
115
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.0
4.0
2.0
2.0
2.0
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
450-1000
400-600
400-600
Technical Data
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
Dielectric Strength
Volume Resistivity
Longitudinal Shrinkage
Water Absorption
Eccentricity
IEC 60243
IEC 60093
ASTM-D-2671
ISO 62
ASTM-D-2671
≥12MPa
≥300%
≥10MPa (130℃,168 hrs)
≥230% (130℃,168 hrs)
≥15 kV/mm
12≥1×10 Ω·cm
≤10%
≤0.5%
≤30%
WRSXPHeat Shrink Repair Sleeve
3837 Product Catalogue www.woer.com
WOER Electrical Power Product
Flame Retarded
Reduces bus bar clearance requirements
Protect against accidental flashover
Anti-track
Halogen free
Tested to IEC60684 standards for medium voltage switch-
gear applications to above 20KV
Continuous Operating Temperature:-40 ℃to 10℃ ,can be
used in 175℃
Shrink Temperature:120℃
RSFRNH-BTM is made from specially formulated radiation cross-linked halogen free compounds. It can provide high
resistance to tracking and arcing, as well as to enhance the insulation properties of bus-bar in switchgear and
substation. Suitable for application in insulating medium voltage bus bars, cable termination and joints from 1KV to
24KV.
Selection Table
Technical Data
RSFRNH-BTMMedium Voltage Cross-linked Polyolefin Bus Bar Tubing
Φ20/6
Φ28/9
Φ33/10
Φ40/12
Φ45/14
Φ55/16
Φ65/19
Φ75/22
Φ85/25
Φ95/30
Φ115/34
Φ130/36
Φ160/50
Φ180/56
6
9
10
12
14
16
19
22
25
30
34
36
50
56
2.2±0.3
2.6±0.3
2.8±0.3
2.8±0.3
3.0±0.3
3.0±0.3
3.0±0.3
3.0±0.3
3.2±0.3
3.2±0.3
3.3±0.3
3.3±0.3
3.3±0.3
3.3±0.3
25
25
25
25
25
25
25
25
25
25
25
25
25
25
After recovered(mm)
Standard length
m/Roll
Normal size(mm) Inside
diameter(Max)Wall thickness
(Min)
As supplied(mm)
Inside diameter(Min)
20
28
33
40
45
55
65
75
85
95
115
130
160
180
Physical
Property Test Method Typical Performance
Heat Aging tensile strength
Tensile strength
Heat shock
Low temperature Flexibility
IEC 60684
150℃╳168h
225℃╳4h
-40℃╳4h
10.5 Mpa
9.5 Mpa
no cracking or flowing
≥8Mpa
≥5Mpa
no cracking or flowing
no cracking no cracking
Elongation
Heat Aging elongation
Flammability
IEC 60684
150℃╳168h
IEC 60684
550%
450%
≥400%
≥200%
Passed Passed
Standard Performance
Electrical
Property Test Method Typical PerformanceStandard Performance
Dielectric Strength IEC 60684 23kv/mm≥20KV/mm
Volume Resistivity
Tracking(2.5kv,60min)
IEC
IEC
60684
60684
142×10 Ω•㎝
no cracking
13≥1×10 Ω•㎝
no cracking
Property
WRSZTHeat Shrink Breakout
Manufactured from cross-linked polyolefin
Provide sealing protection and strain relief over multi-core
cable crutch, including 2-, 3-, 4-, and 5-core breakout
Coated with adhesive on the body and the fingers to form a
watertight seal
Flame-retardant breakouts are available upon customer
request
Meeting with varieties of configuration requirements
Shrink temperature: start at 90℃, and fully recovered at
130℃
Technical Data
Test Method
Standard Value
Insulated Breakout
Oil Resistant Breakout
Semi-conductive Breakout
Tensile Strength
Elongation at Break(120℃,168 hrs)
Tensile Strength after Aging(120℃,168 hrs)
Elongation at Break after Aging
Tensile Strength after Dipping
Elongation at Break after Dipping
Dielectric Strength
Water Absorption
Volume Resistivity
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
ISO 62
IEC 60093
≥12MPa
≥300%
≥10MPa
≥230%
-
-
≥15kV/mm
≤0.5%
13≥1×10 Ω·cm
≥12MPa
≥300%
≥10MPa
≥230%
≥10MPa
≥230%
≥15kV/mm
≤0.5%
≥ 131×10 Ω·cm
≥12MPa
≥300%
≥10MPa
≥230%
-
-
-
≤0.5%
2 410 ~10 Ω·cm
WOER Electrical Power Product
4039 Product Catalogue www.woer.com
Heat Shrink Moulded Shapes
Property Test Method Typical Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
(120℃,168 hrs)
Elongation at Break after Aging
(120℃,168 hrs)
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
Dielectric Strength
Water Absorption
Volume Resistivity
IEC 60243
ISO 62
IEC 60093
≥12MPa
≥300%
≥10MPa
≥230%
≥15 kV/mm
≥ Ω·cm131×10
≤0.5%
Selection Table
WRSZT6Heat Shrink 6-Core Breakout
Made of cross linked polyolefin to provide mechanical protection and strain relief
Inner coated with adhesive on the body and the fingers to form a durable watertight seal
To provide sealing protection over 6-core cable crutch, such as trailing cable, variable frequency drive cable, telecommunication cables, control cable, etc.
Shrink temperature: start at 90℃,and fully recovered at 130℃
Product No.
ID as supplied/mm
Finger diameter Finger diameterBody diameter
(D) Big finger(D2) Big finger(D2)
Body diameter
(D)Small finger(D1) Small finger(D1)
Full length(L)
(±5mm)
Finger length(FL)
(±5mm)
ID after recovered/mm
WRSZT6-133/53(2#)
WRSZT6-86/40(1#) ≥86 ≥32 ≥20
≥133 ≥55 ≥31
220 55 ≤40 ≤11 ≤8
220 55 ≤53 ≤16 ≤11
Technical Data
D
D1
D2
LFL
WOER Electrical Power Product
4241 Product Catalogue www.woer.com
Selection Table
Product No.
Body Diameter
As Supplied (Min) /mm
After Recovered(Max) /mm
Finger Diameter
As Supplied (Min) /mm
After Recovered(Max) /mm
Full Length
(±5mm)Finger Length
(±5mm)
WRSZT2-24/13(0#)
WRSZT2-16/8.5(00#)
WRSZT2-38/17(1#)
WRSZT2-48/22(2#)
WRSZT2-60/25(3#)
WRSZT2-72/25(4#)
2cores
3cores
24
16
38
48
60
72
13
8.5
17
22
25
25
12
8
20
25
35
40
5
3.5
7
10
11
11
130
54
145
145
135
140
55
22
65
60
55
60
WRSZT3-24/16(-2#)
WRSZT3-48/22(-1#)
WRSZT3-60/28(0#)
WRSZT3-140/64(5#)
24
48
60
140
16
22
28
64
11
18
25
65
5
7
8
25
140
170
175
245
50
55
55
90
WRSZT4-38/18(0#)
WRSZT4-50/25(1#)
WRSZT4-109/54(5#)
38
50
109
18
25
54
10
16
42
5
7
18
125
135
235
45
45
65
☆
WRSZT4-70/32(2#) 70 32 23 9 180 65☆
WRSZT4-82/45(3#) 82 45 30 13 210 75☆
WRSZT4-90/45(4#) 90 45 35 13 210 75☆
4cores
5cores
55
60
55
60
80
WRSZT5-42/20(0#)
WRSZT5-57/29(1#)
WRSZT5-70/38(2#)
WRSZT5-90/50(3#)
42
57
70
90
20
29
38
50
48
11
15
23
30
39
5
7
9
13
14
155
170
170
180
205120WRSZT5-120/48(4#)
WRSZT3-125/64(4#) 125 64 58 25 245 95☆
WRSZT3-110/54(3#) 110 54 42 19 250 85☆
WRSZT3-87/46(2#) 87 46 39 16 225 75☆
WRSZT3-70/36(1#) 70 36 30 13 210 70☆
Remark: 1. * means 3-core semi-conductive breakouts are available upon custom request.
2. ☆ means 3-core or 4-core oil resistant breakouts are available upon custom request.
3. The breakout coated with hot-melt adhesive comes in two forms: flat adhesive and
spiral adhesive, which can meet different customer needs.
Selection Table
Made of cross linked polyolefin, inner
coated with adhesive
Sealing and protecting the critical
connection between lead wire and anode
Ideal to avoid premature system failure due
to loss of the wire to anode termination
Continuous operation temperature:
-45℃ to 105℃
Product No.
B.D/mm
As Supplied (Min)
After Recovered (Max)
C.D/mm
As Supplied (Min)
After Recovered(Max)
B.L (±3mm) /mm
C.L (±3mm) /mm
B.W(±0.2mm)
/mm
AC-68/48
AC-87/62
AC-114/86
AC-120/86
AC-86/42
AC-50/30
AC-112/58
68
87
114
120
86
50
112
48
63
86
86
42
30
58
12
12
12
13
16.8
20
16.8
7
7
7
7
6.5
6.5
6.5
76
102
102
102
152
105
152
78
78
78
78
80
45
80
2.5
2.7
2.7
2.7
3.2
3.2
3.2
Technical Data
Property Test Method Standard Value
Tensile Strength
Remark: The anode cap coated with hot-melt adhesive comes in two forms: plane adhesive and spiral adhesive, which can meet different customer needs.
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
Dielectric Strength
Volume Resistivity
Longitudinal Shrinkage
Eccentricity
Water Absorption
Stress Cracking Resistance
Fungus and Decay Resistance
IEC 60243
IEC 60093
ASTM-D-2671
ISO 62
ASTM-D-2671
ASTM-D-1693
ISO 846
≥12MPa
≥300%
≥10MPa (130℃,168 hrs)
≥240%(130℃,168 hrs)
≥15 kV/mm
≥ Ω·cm131×10
≤10%
≤0.5%
≤30%
No cracking
Pass
ACHeat Shrink Anode Cap
B.D
B.L
C.L
C.D
B.W
WOER Electrical Power Product
4443 Product Catalogue www.woer.com
Selection Table
WRSFMHeat Shrink Cable End Cap
Manufactured from polyolefin, applied as insulation of power and telecommunication cable ends
Used to seal cable ends during installation or storage, protecting cable ends against oxidation, ozone, UV, etc
Coated with hot-melt adhesive to ensure reliable seal of cable ends
Flame-retardant end caps are available upon customer request
Available with valve if required
Shrink temperature: start at 90℃, and fully recovered at 130℃
Technical Data
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
≥12MPa
≥300%
≥10MPa (130℃,168 hrs)
≥230% (130℃,168 hrs)
Dielectric Strength
Stress Cracking Resistance
Volume Resistivity
Fungus and Decay Resistance
Longitudinal Shrinkage
Eccentricity
Water Absorption
Low Temperature Flexibility
IEC 60243
ASTM-D-1693
IEC 60093
ISO 846
ASTM-D-2671
ASTM-D-2671
ISO 62
ASTM-D-2671
≥15kV/mm
No cracking
13≥1×10 Ω·cm
Pass
≤10%
≤35%
≤0.5%
No cracking (-40℃, 4 hrs)
Remark: The end cap coated with hot-melt adhesive comes in two forms: flat adhesive and spiral adhesive, which can meet different customer needs.
Product No.D/ mm
As Supplied (Min) After Recovered (Max)L/ mm(±5mm)
W/mm
After Recovered (±0.1mm)
WRSFM -25/11
WRSFM -30/16
WRSFM -40/15
WRSFM -35/17
WRSFM -55/26
WRSFM -74/31
WRSFM -97/40
WRSFM -120/57
WRSFM -140/63
WRSFM -200/95
WRSFM -245/95
WRSFM-12/5
WRSFM -16/8.5
WRSFM -20/8.5
12
16
20
25
30
35
40
55
74
97
120
140
200
245
5
8.5
8.5
11
16
17
15
26
31
40
57
63
95
95
45
70
72
84
94
94
94
125
145
140
150
184
280
280
2.5
2.5
2.5
2.5
3.0
2.6
2.6
2.5
3.2
5.0
4.4
4.0
4.0
4.0
D
L
W
Product No.
Technical Data
Property Test Method Standard Value
As Suppliedd/mm(Min.)(±3mm)
After Recoveredd/mm(max)
W/mm(±0.2mm)
D/mm
WRS -30/13RS
WRSRS-35/13
WRSRS-40/20
WRSRS-45/20
WRSRS-50/20
30
35
40
45
50
13
13
20
20
20
2.095
1.995
2.0120
1.8120
1.6120
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Dielectric Strength
Tracking Resistance
Volume Resistivity
Dielectric Constant
Water Absorption
Eccentricity
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
IEC 60587
IEC 60093
IEC 60250
ISO 62
ASTM-D-2671
≥11.8MPa
≥400%
≥6MPa (130℃,168 hrs)
≥350% (130℃,168 hrs)
≥15kV/mm
1A 3.5
14≥1×10 Ω·cm
≤5.0
≤0.5%
≤35%
Cold Bend ASTM-D-2671 No cracking
Selection Table
WRSRSHeat Shrink Anti-tracking Rain Shed
Manufactured from polyolefin, coated with anti-
tracking adhesive
High creep resistance and anti-tracking property
Shaped components to meet a range of requirements
WOER Electrical Power Product
4645 Product Catalogue www.woer.com
Selection Table
Product No.
Product No.
Technical Data
Property Test Method Standard Value
Manufactured from polyolefin, coated with anti-
tracking adhesive
High creep resistance and anti-tracking property
Shaped components to meet a range of requirements
WRSSQHeat Shrink Anti-tracking Rain Shed
As Suppliedd/mm(Min.)(±3mm)
As Suppliedd/mm(Min.)(±3mm)
After Recoveredd/mm(max)
After Recoveredd/mm(max)
D/mmW/mm
(±0.2mm)
W/mm(±0.2mm)
WRSSQ-35/17
WRSSQ-35/15
WRSSQ-40/24
WRSSQ-45/21
WRSSQ-50/24
WRSSQ-50/21
WRSSQ-60/32
WRSSQ-70/32
WRSSQ-80/32
35
35
40
45
50
50
60
70
80
17
16
24
22
24
22
32
32
32
105
105
105
140
140
140
2.8
2.8
2.6
3.0
2.6
3.0
4.0
4.0
4.0
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Dielectric Strength
Tracking Resistance
Volume Resistivity
Dielectric Constant
Water Absorption
Eccentricity
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
IEC 60587
IEC 60093
IEC 60250
ISO 62
ASTM-D-2671
≥10.8MPa
≥300%
≥8MPa (130℃,168 hrs)
≥240% (130℃,168 hrs)
≥20kV/mm
1A 3.5
14≥1×10 Ω·cm
≤5.0
≤0.5%
≤35%
Cold Bend ASTM-D-2671 No cracking
d
D
W
(1-core Rain Shed)
(3-core Rain Shed)
D
W
d
Selection Table
WRSLTHeat Shrink Cable Entry Seal
Made of flame-retardant polyolefin, inner coated
with adhesive to provide sealing protection
Provides a watertight and fume-tight seal where
cables enter connection boxes, bulkheads, or
other enclosures
Consists of a three-part assembly- a rigid plastic
nut, O-ring, and a heat shrink moulded body
Continuous operation temperature: -55℃ to 90℃
Part Number
Part Number
After Recovered Length (L)(mm)
As Supplied(Min)/mm
As Supplied(Min)/mm
Full Length
( 5mm)±
After Recovered(Max) /mm
After Recovered(Max) /mm
Finger Length
(±5mm)
Body Diameter Finger Diameter As Supplied
As SuppliedNose I.D. (( I.D.N,Min)/mm
After RecoveredNose I.D. (I.D.N,Max)/mm
Body
I.D(I.D.A, mm)±5Drill Size
(mm)
WRSLT-4
WRSLT-5
WRSKT-20/8(0#)
WRSKT-30/13(1#)
WRSKT-40/15(2#)
WRSKT-50/17(3#)
WRSKT-65/17(4#)
112±5
175±5
20 8
30 13
40 15
50 17
65 17
45
70
10
16
20
25
35
19
36
4
7
9
11
11
41
74
135
135
140
135
135
51
90
60
60
65
60
50
WRSKT2-core Clip-on Breakout
Manufactured from polyolefin, with a stainless steel
channel sliding over the rail
Mostly used to provide sealing and protection for
bifurcated cable, especially for the branch cable lapping
on the main cable
WOER Electrical Power Product
4847 Product Catalogue www.woer.com
D1
D1
D2
D2
W1
W1
W2
W2
78°
L2
L1
L
L1L2
Technical Data
Property Test Method Standard Value
WRSJXHeat Shrink Right Angle/In-line Bushing Boot
Manufactured from polyolefin, inner coated with hot-melt adhesive at the ends
Used to protect cable against flashover or surges induced in switchgear and transformer
Shaped components to meet a range of requirements
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
Dielectric Strength
Tracking Resistance
Volume Resistivity
Dielectric Constant
Longitudinal Shrinkage
Eccentricity
Water Absorption
Flammability (Oxygen Index)
Copper Corrosion
Cold Bend
Heat Shock
ASTM-D-638
ASTM-D-638
ASTM-D-638
ASTM-D-638
IEC 60243
IEC60587
IEC 60093
ASTM-D-150
ASTM-D-2671
ASTM-D-2671
ISO 62
ISO 4589
ASTM-D-2671
ASTM-D-2671
ASTM-D-2671
≥10.8MPa
≥300%
≥8MPa(130℃,168 hrs)
≥240% (130℃,168 hrs)
≥25kV/mm
1A 3.5
14≥1×10 Ω·cm
≤3.0
≤10%
≤30%
≤0.5%
≥25
No corrosion (130℃,168 hrs)
No cracking (-40℃,4 hrs)
No cracking or flowing(160℃,4 hrs)
Selection Table
Product No.As Supplied/mm
D1(Min)
D2(Min)
After Recovered/mm
D1(Max)
D2(Max)
L1(Nom.)
L2
(±10%)
L
(±10%)
W1
(±10%)
W2
(±10%)
18
18
27
28
34
170
170
160
160
215
125
125
140
140
140
--
--
--
--
--
4.2
4.2
4.2
4.2
4.2
3.8
3.8
3.8
3.8
4.2
WRSJX-R1
WRSJX-R2
WRSJX-R3
WRSJX-R4
WRSJX-R5
80
80
80
95
145
35
50
50
70
68
36
36
36
38
72
Right Angle Boot
In-line Bushing Boot
WRSJX-S1
WRSJX-S2
WRSJX-S3
80
80
140
34
58
90
32
32
65
19
19
33
145
145
145
30
30
40
220
220
220
3.2 3.2
3.2 3.2
3.2 3.2
Technical Data
Property
Physical properties
Test Method Standard Value
Tensile Strength
Elongation at Break
Tensile Strength after Aging
Elongation at Break after Aging
(130℃, 168h)
Heat shock(200℃, 4h)
Low temperature flexibility
Oxygen index
Solvent resistance
(23℃,24h)
Gasoline
Diesel oil
Acid & alkali
Dielectric strength
Tensile strength
Tensile strength
Tensile strength
Elongation at break
Elongation at break
Elongation at break
ASTM-D-2671
ASTM-D-2671
ISO 868
ASTM-D-2671
UL 224
ISO 974
ISO 4589
IEC 60243
ASTM-D-2671
ASTM-D-2671
ASTM-D-2671
ASTM-D-2671
ASTM-D-2671
ASTM-D-2671
≥15MPa
≥500%
90±2
≥400%
No dripping, flowing or cracking
﹣55℃
≥28
≥20kV/mm
≥11MPa
≥400%
≥10MPa
≥350%
≥12MPa
≥400%
WOER Electrical Power Product
5049 Product Catalogue www.woer.com
Product No. L1/mmD1/mm D2/mm
As Supplied As SuppliedAfter Recovered After Recovered
L2/mm
WRSY-28/13 120±2 ≥28 ≥938±2 ≤13 ≤3.5
WRSY Y-type Heat Shrink Tube
Made of cross-linked polyolefin.
Mostly used to provide sealing and protection for
bifurcated cable, especially for the branch cable lapping
on the main cable
Shrink temperature: start at 90℃, and fully recovered at
130℃
Selection Table
Technical Data
Property Test Method Standard Value
Tensile Strength
Elongation at Break
Dielectric Strength
Volume Resistivity
ASTM-D-638
ASTM-D-638
IEC 60243
IEC 60093
≥10.8MPa
≥300%
≥20kN/m
≥ 131×10 Ω·cm
Heat Shrink ight Angled BootR
Features
Selection Table
Made of semi-rigid flame-retarded polyolefin.
Provide strong mechanical protection, connector/cable strain relief, and complete environmental sealing.
This family of boots has no lip.
Provided with or without adhesive lining.
Standard colour: Black.
W11
Product No. As Supplied
Specifcation As Supplied
H L1
±10%
L2
±10%
δ
±20%After
RecoveredAfter
Recovered
D1 D2
W1111
W1121
W1131
W1161
W1141
W1171
W1181
W1151
18 18 4.018/7-4 7 8.8-15.0
22 22 5.022/11-5 11 13.0-18.5
36 36 8.036/16/8
60 60 15.060/30-15
16 20.0-30.0
30 35.0-50.0
42 42 10.042/24-10
65
65
65 16.5
70 20.0
65/35-16
70/40-20
24 28.0-36.0
35
40
41.0-54.0
47.0-58.0
52 52 15.052/26-15 26 30.0-43.0
5.0-10.0
6.2-12.0
10.0-20.0
17.6-36.0
11.8-24.0
19.4-38.0
24.0-48.0
17.0-36.0
25 28 12 1.8
27 36 18 2.0
32 42 20 2.0
44 78 29 3.0
36 56 21 2.2
40
52
85
85
28
28
3.2
3.5
38 57 21 2.2
Range OfApplication
Range OfApplication
WOER Electrical Power Product
5251 Product Catalogue www.woer.com
Heat Shrink Straight BootCableZ11
Features
Selection Table
Made of semi-rigid flame-retarded polyolefin.
Used for strong mechanical protection, connector/cable strain relief, and complete environmental sealing.
This family of boots has no lip.
Provided with or without adhesive lining.
Standard colour: Black.
Product No. As Supplied
Specifcation As Supplied
L
±10%
L1
±10%
L2
±10%
δ
±20%After
RecoveredAfter
Recovered
D1 D2
W1111
W1121
W1131
W1161
W1141
W1171
W1151
11 1111/5-2 5.0 6.6-9.0
18 1818/7-4 7.0 8.8-15.0
24 2424/11-5.6
40 4040/22.4-8.4
11.0 14.0-20.0
22.4 26-32.0
30 3030/14.3-6.6
46 4646/28-10
14.3 17.8-25.0
28.0 32-36.0
32 3232/17.8-7.2 17.8 22.3-27.0
2.0 2.2-5.6
4.0 5.0-10.0
5.6 7.0-14.0
8.4 10.0-21.0
6.6 8.2-16.0
10.0 11.8-24.0
7.2 9.0-18.0
40 21 12 1.8
50 19 28 2.0
50 27 16 2.0
82 52 20 2.2
60 39 16 2.0
85 45 20 2.5
68 40 18 2.2
Range OfApplication
Range OfApplication
C3111
C3121
C3131
C3141
C3151
6.6 6.6 4614 3.6
13.2 13.2 9427 6.9
18.8 19.3 13539 9.7
25.4 27.0 19256 12.4
54.0 46.0 39092 27.0
31 15.7 2.0 1.5
57 33.0 2.5 2.0
89 46.0 3.0 2.5
122 71.0 4.0 3.0
254 127.0 6.0 3.0
Heat Shrink 3-Way outlet Shapes
L
±10%
L1
±10%
L2
±10%
δ
±20%2δ1
±20%
Features
Selection Table
Made of semi-rigid flame-retarded polyolefin.
Provide strong mechanical protection, strain relief, and complete environmental sealing on cable harness
assemblies.
Provided with or without adhesive lining.
Standard colour: Black.
Product No.
C31
WOER Electrical Power Product
5453 Product Catalogue www.woer.com
Heat Shrink 2-Way outlet Shapes
Features
Selection Table
Made of semi-rigid flame-retarded polyolefin.
Provide strong mechanical protection, strain relief, and complete environmental sealing on cable
harness assemblies.
Provided with or without adhesive lining.
Standard colour: Black.
L
±10%
L1
±10%
L2
±10%
δ
±20%
δ2 3δ1
±20%Product No.
C21
C2111
C2121
C2131
C2141
13.5 3.36.0 6.6
27.0 6.112.4 13.2
39.0 12.418.0 27.0
56.0 12.726.0 27.0
24.0 15.5
53.3 33.0
79.0 56.0
112.0 71.0
25 2.0 1.5
55 2.5 2.0
80 3.0 2.5
114 3.6 2.5
Cold shrink cable accessories are capable of shrinking without application of heat.
They are manufactured in a pre-expanded condition and assembled onto a
removable core. The core is removed after the tube is positioned over the cable for
installation, allowing the tube to shrink and providing a moisture-tight seal.
Woer cold shrink cable accessories are characterized by simple solutions with
safe connection. They are manufactured with liquid silicone rubber, which has
high-quality electrical insulation, excellent tracking resistance as well as high
elasticity.
Cold Shrink Cable Accessories
WOER Electrical Power Product
5655 Product Catalogue www.woer.com
C4111
C4121
C4131
C4161
C4141
C4151
6.9 3.413.2 6.6
9.7 5.319.3 9.4
9.7 6.919.3
26.7 13.055.6
13.2
26.9
13.0 6.926.9 13.2
18.5 9.738.6 19.3
24.1
35.6
49.3
101.6
49.3
71.9
43.2 18.0 1.5 1.0
43.2 23.1 2.0 1.5
50.5 25.4 2.5 1.8
135.1 65.5 4.5 2.5
65.8 33.5 2.5 1.8
95.3 46.5 3.0 2.0
Heat Shrink 4-Way outlet Shapes
L
±10%
L1
±10%
L2
±10%
δ
±20%2δ1
±20%
Features
Selection Table
Made of semi-rigid flame-retarded polyolefin.
Provide strong mechanical protection, strain relief, and complete environmental sealing on cable harness
assemblies.
Provided with or without adhesive lining.
Standard colour: Black.
Product No.
C41
8.7/15 kV(17.5)
1, 3 Outdoor
4.5
4.5
1, 3Indoor
25-50
70-120
150-240
300-400
500-630
25-50
70-120
150-240
300-400
500-630
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
17.5kVWLN- 1/1(3/1)
17.5kVWLN- 1/2(3/2)
17.5kVWLN- 1/3(3/3)
17.5kVWLN-1/4(3/4)
17.5kVWLN-1/5(3/5)
17.5kVWLW- 1/1(3/1)
17.5kVWLW- 1/2(3/2)
17.5kVWLW- 1/3(3/3)
17.5kVWLW-1/4(3/4)
17.5kVWLW-1/5(3/5)
Selection Table
1, 3 Outdoor
Voltage U /U (U )0 m CoresCable Cross
2Section /mmNominal insulation thickness /mm
Diameter over Insulation /mm Kit No.
19/33
18/30 kV(36)
(36)kV
20.8/36(42)kV
26/35(42)kV
26/35(42)kV
12/20 kV
12.7/22
(24)
(24)kV
6/10 kV
6.35/11
(12)
(12)kV
0.6/1 kV(1.2)
1, 3 Outdoor
1, 3 Outdoor
1, 3 Outdoor
1, 3 Indoor
1, 3 Indoor
1, 3 Indoor
9.3
10.5
9.3
10.5
8.0
8.0
5.5
5.5
3.4
3.4
35-50
70-185
240-500
630
50-95
120-240
300-400
500-630
50-95
120-240
300-400
500-630
35-50
70-185
240-500
630
50-95
120-240
300-400
500-630
50-95
120-240
300-400
500-630
22-27
27.5-35
35.5-46
46.5-55
28.5-35
35.5-42
42.5-48
48.5-56
28.5-35
35.5-42
42.5-48
48.5-56
36kVWLW-1/1(3/1)
36kVWLW-1/2(3/2)
36kVWLW-1/3(3/3)
36kVWLW-1/4(3/4)
42kVWLW-1/1(3/1)
kVWLW-1/2(3/2)
kVWLW-1/3(3/3)
kVWLW-1/4(3/4)
42
42
42
42
42
42
42
kVWLW-1/1(3/1)
kVWLW-1/2(3/2)
kVWLW-1/3(3/3)
kVWLW-1/4(3/4)
22-27
27.5-35
35.5-46
46.5-55
28.5-35
35.5-42
42.5-48
48.5-56
28.5-35
35.5-42
42.5-48
48.5-56
36kVWLN-1/1(3/1)
36kVWLN-1/2(3/2)
36kVWLN-1/3(3/3)
36kVWLN-1/4(3/4)
42kVWLN-1/1(3/1)
kVWLN-1/2(3/2)
kVWLN-1/3(3/3)
kVWLN-1/4(3/4)
42
42
42
42kVWLN-1/1(3/1)
kVWLN-1/2(3/2)
kVWLN-1/3(3/3)
kVWLN-1/4(3/4)
42
42
42
1, 3Indoor
1, 3Outdoor
1, 3Indoor
25-50
70-120
150-240
300-400
500-630
25-50
70-120
150-240
300-400
500-630
18-21.5
21-26.5
25.5-32
32.5-37
39-44.3
24kVWLN-1/1(3/1)
24kVWLN-1/2(3/2)
24kVWLN-1/3(3/3)
24kVWLN-1/4(3/4)
24kVWLN-1/5(3/5)
18-21.5
21-26.5
25.5-32
32.5-37
39-44.3
24kVWLW-1/1(3/1)
24kVWLW-1/2(3/2)
24kVWLW-1/3(3/3)
24kVWLW-1/4(3/4)
24kVWLW-1/5(3/5)
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
50-70
95-150
185-300
400-500
630
12kVWLN- 1/1(3/1)
12kVWLN- 1/2(3/2)
12kVWLN-1/3(3/3)
12kVWLN-1/4(3/4)
12kVWLN-1/5(3/5)
50-70
95-150
185-300
400-500
630
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
12kVWLW- 1/1(3/1)
12kVWLW- 1/2(3/2)
12kVWLW- 1/3(3/3)
12kVWLW- 1/4(3/4)
12kVWLW- 1/5(3/5)
1,3,4, 5
Indoor orOutdoor
25-50
70-120
150-240
300-400
--
1.2kVWLT-1(3,4,5)/1
1.2kVWLT-1(3,4,5)/2
1.2kVWLT-1(3,4,5)/3
1.2kVWLT-1(3,4,5)/4
WOER Electrical Power Product
5857 Product Catalogue www.woer.com
1. Environmental top sealing treatment
Three steps to provide a seal to against the entrance of the external environment.
2. Excellent external housing
Imported LSR offers excellent hydrophobicity and great anti-tracking property to ensure the power safety.
3. Stress control
Stress cone adopts well designed geography analysis to smooth out the high stress area.
4. Earth connection
Adopt Solderless earth connection to connect metal screen or armour to ground. For cables with wire screen,
copper wires are imbedded in the sealing mastic to prevent any corrosion by moisture sealing.
Terminations can be ordered as standard kits (without lugs or other accessories) or complete kits.
Terminations and components for other cable types are available on request.
Features:
Note:
WLN, WLWCold shrink termination up to 42 kV
Up to 42kV
6/10(12)
6.35/11(12)
8.7/15(17.5)
12/20(24)
12.7/22(24)
18/30(36)
19/33(36)
20.8/36(42)
WCSITIndoor Termination
Note: The final determination factor is the cable insulation diameter.
12WCSIT01
12WCSIT02
503.4
254.5
255.5
358.0
953.4
704.5
705.5
958.0
70
50
50
70
150
120
120
185
16
16
16
25.5
20.5
20.5
20.5
30.5
20
20
20
30
25
25
25
36
12
17.5
24
36
42
42
Kit No.Nominal insulation
thickness /mm
Conductor Cross Section 2/mm
Diameter over Insulation
/mmVoltage
Um (kV)minmin maxmax
12WCSIT03
12WCSIT04
12WCSIT05
1853.4
1504.5
1505.5
2408.0
120
120
9.3
10.5
4003.4
3004.5
3005.5
5008.0
300
300
9.3
10.5
300
240
240
400
240
240
500
400
400
630
400
400
25.5
25.5
25.5
36.5
36.5
36.5
30.5
30.5
30.5
43.5
43.5
43.5
30
30
30
43
43
43
36
36
36
48
48
48
17.5WCSIT01
24WCSIT01
36WCSIT43
17.5WCSIT02
24WCSIT02
36WCSIT44
17.5WCSIT03
24WCSIT03
36WCSIT45
42WCSIT85
42WCSIT85
17.5WCSIT04
24WCSIT04
36WCSIT46
42WCSIT86
42WCSIT86
17.5WCSIT05
24WCSIT05
42WCSIT84
42WCSIT84
42WCSIT87
42WCSIT87
6303.4
5004.5
5005.5
50
50
9.3
10.5
500
500
9.3
10.5
/
630
630
95
95
630
630
36.5
36.5
36.5
30.5
30.5
48.5
48.5
43
43
43
36
36
55
55
WOER Electrical Power Product
6059 Product Catalogue www.woer.com
WCSIT/WCSOTPA Termination Series
One-piece Design, easiest installation
No extra stress relief compound and top sealing mastic needed. All you need to do is shrink it into place.
Excellent performed material, longer life time
Improved stress control tube, excellent hydrophobicity and great anti-tracking property to ensure the
power safety.
Specification and standard
High dielectric constant stress relief compound
Note: The final determination factor is the cable insulation diameter.
High dielectric constant stress control tube
Excellent hydrophobicity housing
Built-in top sealing mastic
Meets the requirements of IEC60502.4
Highlights
1. Joint Body
One-piece design to provide the insulation and insulation screen to recover the cable structure.
2. Electrical stress control
Stress control tube, together with stress cone are used to smooth out the electrical field at the insulation
screen cuts.
3. Metallic shielding
Copper mesh which has been secured with solderless earth connection is wrapped around the joint area to
rebuild the metallic screen and provide screen continuity across the joint.
4. Outer sealing and protection
The outer sealing and protection is performed by both the waterproof tape and arour tape. So they provide
mechanical protection and chemical resistance as expected from cable oversheath.
Note:
Joints can be ordered as standard kits (without connectors or other accessories) or complete kits.
Joints and components for other cable types are available on request.
Connectors need to be ordered separately.
WLJ Cold Shrink Joint up to 42 kV
2
312
Cable1 Cable2
4
WOER Electrical Power Product
6261 Product Catalogue www.woer.com
Note: The final determination factor is the cable insulation diameter.
Up to 42kV
6/10(12)
6.35/11(12)
8.7/15(17.5)
12/20(24)
12.7/22(24)
18/30(36)
19/33(36)
20.8/36(42)
WCSOTOutdoor Termination
12WCSOT41
12WCSOT42
50
254.5
255.5
358.0
953.4
704.5
705.5
958.0
70
50
50
70
150
120
120
185
16
16
16
25.5
20.5
20.5
20.5
30.5
20
20
20
30
25
25
25
36
12
17.5
24
36
42
42
Kit No.
2Conductor Cross Section /mm Diameter over Insulation /mmVoltage
Um (kV)minmin maxmax
12WCSOT43
12WCSOT44
1853.4
1504.5
1505.5
2408.0
120
120
9.3
10.5
4003.4
3004.5
3005.5
5008.0
300
300
9.3
10.5
300
240
240
400
240
240
500
400
400
630
400
400
25.5
25.5
25.5
36.5
36.5
36.5
30.5
30.5
30.5
43.5
43.5
43.5
30
30
30
43
43
43
36
36
36
48
48
48
12WCSOT45
17.5WCSOT41
24WCSOT41
36WCSOT43
17.5WCSOT42
24WCSOT42
36WCSOT44
17.5WCSOT43
24WCSOT43
36WCSOT45
42WCSOT85
42WCSOT85
17.5WCSOT44
24WCSOT44
36WCSOT46
42WCSOT86
42WCSOT86
17.5WCSOT45
24WCSOT45
42WCSOT84
42WCSOT84
42WCSOT87
42WCSOT87
6303.4
5004.5
5005.5
50
50
9.3
10.5
500
500
9.3
10.5
/
630
630
95
95
630
630
36.5
36.5
36.5
30.5
30.5
48.5
48.5
43
43
43
36
36
55
55
3.4
Nominal insulation
thickness /mm
WCSTCold Shrink Silicone Rubber Tube
Remark: ID* means inner diameter.
Selection Table
Product No.ID* Expanded (Max) /mm
Required Length (After Relaxed)/mm
Thickness (After Relaxed)/mm
Application Range/mm
WCST20
WCST28
WCST32A
WCST32B
WCST35
WCST40
WCST47
WCST53
WCST65
WCST70
WCST80A
WCST80B
WCST88
WCST104
WCST110A
WCST110B
WCST150
20
28
32
32
35
40
47
53
65
70
80
80
88
104
110
110
150
2.0±0.2
2.5±0.2
2.5±0.2
2.0±0.2
2.0±0.2
2.0±0.2
2.0±0.2
2.0±0.2
3.0±0.2
3.0±0.2
3.0±0.2
3.0±0.2
3.0±0.2
3.0±0.2
6.0±0.2
6.0±0.2
3.0±0.2
80~450
80~500
80~490
80~490
80~450
80~450
80~470
80~500
80~500
80~500
80~500
80~500
80~500
80~500
80~420
80~420
80~480
Φ10~Φ14
Φ12~Φ17
Φ13.2~Φ22.4
Φ17~Φ24
Φ19~Φ28
Φ21~Φ31
Φ25~Φ37
Φ31~Φ45
Φ31~Φ45
Φ37~Φ55
Φ37~Φ55
Φ44~Φ65
Φ44~Φ65
Φ51 ~Φ76
Φ45~Φ66
Φ72~Φ105
Φ92~Φ135
Manufactured from silicone rubber
Offering good mechanical, insulation and sealing protection
Accommodating a wide range of cable sizes
For indoor or outdoor applications
Simple and fast installation
Color:grey,black
WOER Electrical Power Product
6463 Product Catalogue www.woer.com
Selection Table
12/20 kV
(24)
18-21.5
21-26.5
25.5-32
32.5-37
39-44.3
24kVWLJ-1/1(3/1)
kVWLJ-1/2(3/2)
kVWLJ-1/3(3/3)
kVWLJ-1/4(3/4)
kVWLJ-1/5(3/5)
24
24
24
24
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
35-50
70-120
150-240
300-400
500-630
50-95
120-240
300-400
500-630
50-95
120-240
300-400
500-630
25-50
70-120
150-240
300-400
500-630
22-28
26.5-33
31.5-39
35.5-43
40.5-49
28.5-35
35.5-42
42.5-48
48.5-56
28.5-35
35.5-42
42.5-48
48.5-56
36kVWLJ-1/1(3/1)
36kVWLJ-1/2(3/2)
36kVWLJ-1/3(3/3)
36kVWLJ-1/4(3/4)
36kVWLJ-1/5(3/5)
42kVWLJ-1/1(3/1)
kVWL -1/2(3/2)
kVWL -1/3(3/3)
kVWL -1/4(3/4)
42 J
42 J
42 J
42kVWLJ-1/1(3/1)
42kVWL -1/2(3/2)
42kVWL -1/3(3/3)
42kVWL -1/4(3/4)
J
J
J
1, 3, 4, 5
8.7/15 kV
(17.5)
6/10 kV
(12)
0.6/1 kV
(1.2)
25-50
70-120
150-240
300-400
500-630
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
17.5kVWLJ-1/1(3/1)
kVWLJ-1/2(3/2)
kVWLJ-1/3(3/3)
kVWLJ-1/4(3/4)
kVWLJ-1/5(3/5)
17.5
17.5
17.5
17.5
50-70
95-150
185-300
400-500
630
25-50
70-120
150-240
300-400
16-19.5
19-24.5
23.5-30
30.5-35
37-42.3
——
12kVWLJ-1/1(3/1)
12kVWLJ-1/2(3/2)
12kVWLJ-1/3(3/3)
12kVWLJ-1/4(3/4)
12kVWLJ-1/4(3/4)
1.2kVWLJ-1(3,4,5)/1
kVWLJ-1(3,4,5)/2
kVWLJ-1(3,4,5)/3
kVWLJ-1(3,4,5)/4
1.2
1.2
1.2
Voltage U /U (U ) CoresCable Cross
2Section/mmDiameter over Insulation/mm Kit No.
18/30 kV
(36)
20.8/36(42)kV
26/35(42)kV
0 m
9.3
10.5
8.0
5.5
4.5
3.4
Nominal insulation
thickness /mm
WCSFCold Shrink Silicone Rubber Breakout
Manufactured from silicone rubber
Simple and fast installation meeting a variety of
configuration requirements
Providing sealing protection over multi-core cable
crutch, including 3-, 4-, 5-, 6-core breakouts
Selection Table
Ø C Expanded (max)/mm
Application Range/mm
ØF Expanded (max)/mm
Application Range/mm
L /mmF L /mmC
WCSF 3-1(1#)
WCSF 3-2(2#)
WCSF 3-3(3#)
WCSF 3-4(4#)
WCSF 3-5(5#)
WCSF 3-5A1(6#)
WCSF 3-5A2(7#)
WCSF 4-1(1#)
WCSF 4-2(2#)
WCSF 4-3(3#)
WCSF 4-4(4#)
WCSF 5-1(1#)
WCSF 5-2(2#)
WCSF 5-3(3#)
WCSF 5-3A(4#)
WCSF 6-1(1#)
WCSF 6S-1(1#)
3
4
5
6
80
88
104
120
140
150
165
65
80
88
120
80
88
110
120
104
104
Ø48-Ø67
Ø54-Ø78
Ø62-Ø90
Ø72-Ø105
Ø88-Ø120
Ø88-Ø128
Ø88-Ø138
Ø26-Ø45
Ø36-Ø63
Ø51-Ø75
Ø56-Ø92
Ø36-Ø62
Ø46-Ø73
Ø59-Ø95
Ø59-Ø110
Ø44-Ø80
Ø44-Ø80
32
35
40
47
60
65
70
20
25
32
47
20
25
35
40
32
28 (3 small fingers)
Remark: 1. 6-Core breakouts (with 3 big fingers and 3 small fingers) are used on trailing cable, variable frequency cables, telecommunication cables, control cables, etc. 2. Special specification is available per different requirements.
35 (3 big fingers)
Ø19-Ø28
Ø21-Ø31
Ø25-Ø37
Ø31-Ø45
Ø36-Ø50
Ø36-Ø52
Ø36-Ø57
Ø10-Ø14
Ø12-Ø17
Ø14-Ø21
Ø19-Ø30
Ø10-Ø14
Ø12-Ø17
Ø16-Ø22
Ø16-Ø25
Ø14-Ø21
Ø14-Ø21
Ø14-Ø24
45
45
45
45
55
55
55
35
40
40
40
40
40
45
45
60
60
60
130
135
150
165
180
180
180
126
137
145
145
123
134
138
138
135
135
135
Product No. Cores
WOER Electrical Power Product
6665 Product Catalogue www.woer.com
WEPDMCCold Shrink EPDM Tube
Manufactured from EPDM rubber
Offering good mechanical, insulation and sealing
protection
Accommodating a wide range of cable sizes
For indoor or outdoor applications
Simple and fast installation
Selection Table
Product No.
Product No.
Size
Size
Cold Shrink Tube of High Shrinkage Ratio EPDM
Cold Shrink Tube of General EPDM
8435-L8435-L
8320-6
Φ35Φ35
Φ20
12.5~30/0.49~1.1812.5~30/0.49~1.18
8~15/0.30~0.59
229~279/9~11229~279/9~11
152/6
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM RubberEPDM Rubber
EPDM Rubber
EPDM Rubber
EPDM Rubber
EPDM Rubber
BlackBlack
Black
BlackBlack
Black
BlackBlack
Black
BlackBlack
Black
BlackBlack
Black
BlackBlack
Black
Black
Black
Black
8440-L8440-L
8325-L
Φ40Φ40
Φ25
14~33/0.55~1.3014~33/0.55~1.30
10~20/0.39~0.79
152~406/6~16152~406/6~16
203~280/8~11
8453-L8453-L
8335-L
Φ53Φ53
Φ35
19~46/0.75~1.8119~46/0.75~1.81
14~30/0.55~1.18
152~457/6~18152~457/6~18
229~280/9~11
8460-108460-10
8340-L
Φ60Φ60
Φ40
20.5~51/0.81~2.0120.5~51/0.81~2.01
17.5~33/0.69~1.30
254/10254/10
152~457/6~18
8470-L8470-L
8353-L
Φ70Φ70
Φ53
25~63/0.98~2.4825~63/0.98~2.48
25~46/0.98~1.81
152~457/6~18152~457/6~18
152~457/6~18
8480-138480-13
8370-L
8104-9
8125-9
8150-18
Φ80Φ80
Φ70
Φ104
Φ125
Φ150
27.4~70/1.08~2.7527.4~70/1.08~2.75
32~63/1.26~2.48
43~94/1.69~3.70
46~114/1.81~4.49
55-135/2.17~5.31
325/13325/13
152~457/6~18
229/9
229/9
457/18
Application Range(mm/inch)
Application Range(mm/inch)
Length after Relaxed(mm/inch)
Length after Relaxed(mm/inch)
Material
Material
Color
Color
Remark: L indicates the required length after relaxed with the unit of mm or inch.