Page 1 of 54 Report No.:L651721L215 Sporton International Inc. LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology equipment – Safety – Part 1: General requirements Report Reference No. ....................... : L651721L215 Compiled by (+ signature) ................. : Ben Chang Engineer Approved by (+ signature) ................. : Peter Hsu Reviewer Date of Issue ..................................... : June 15, 2016 Testing laboratory .............................. : Sporton International Inc. (Safety Lab.) Address.............................................. : 14 Fl-2, No. 186, Jianyi Road, Zhonghe District, New Taipei City Testing location ................................. : Taiwan Applicant ............................................ : Laird Technologies Address.............................................. : 11160 Thompson Ave., Lenexa, Kansas 66219, USA Standard ............................................ : IEC 60950-1: 2005 (2nd Edition)+ Am 1:2009 +Am2:2013; and/or EN 60950-1: 2006+A11:2009+A1:2010+A12:2011+A2:2013 Test Report Form No. ....................... : LVD 60950-1 Test procedure ................................. : Sporton LVD type test approval Procedure deviation........................... : N/A Non-standard test method................. : N/A Type of test object ............................. : 802.11abn (1x1) + Bluetooth (2.1) module Trademark ......................................... : Laird Technologies Model/type reference ......................... : SDC-SSD40NBT Manufacturer ..................................... : Laird Technologies 11160 Thompson Ave., Lenexa, Kansas 66219, USA Rating................................................. : DC 3.3V
57
Embed
LVD Test Report - Laird Techcdn.lairdtech.com/home/brandworld/files/EN60950 Test...2.1.1.9 Audio amplifiers N.A. 2.1.2 Protection in service access areas N.A. 2.1.3 Protection in restricted
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1 of 54 Report No.:L651721L215
Sporton International Inc.
LOW VOLTAGE DIRECTIVE TEST REPORT
IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN
Address .............................................. : 11160 Thompson Ave., Lenexa, Kansas 66219, USA
Standard ............................................ : IEC 60950-1: 2005 (2nd Edition)+ Am 1:2009 +Am2:2013; and/or EN 60950-1: 2006+A11:2009+A1:2010+A12:2011+A2:2013
Test Report Form No. ....................... : LVD 60950-1
Test procedure ................................. : Sporton LVD type test approval
[] stationary [X] for building-in [] direct plug-in
Connection to the mains ............................................ : [] pluggable equipment [] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord
IP protection class ...................................................... : IPX0
Altitude during operation (m) ...................................... : Up to 2000 m
Altitude of test laboratory (m) ..................................... : Not over 2000 m
Mass of equipment (Kg) ............................................. : 0.001kg
Test case verdicts
Test case does not apply to the test object ................... : N (N.A.)
Test item does meet the requirement ........................... : P (Pass)
Test item does not meet the requirement ..................... : F (Fail)
Testing:
- Date of receipt of test item .......................................... : 2016-05-19
- Date(s) of performance of test .................................... : 2016-05-19
General remarks:
The test result presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
Page 3 of 54 Report No.:L651721L215
Sporton International Inc.
Comments:
The test results are true for the test sample(s) only.
A part of this test report or certificate should not be duplicated in any way; however, the duplication of the whole document is allowed.
This test-report includes the following documents:
Test report - ( 54 pages)
Appendix - Photo ( 03 pages)
General product information:
The equipment is a 802.11abn (1x1) + Bluetooth (2.1) module (Wireless & Bluetooth module), intended for used with information technology equipment.
The equipment was evaluated for use in a maximum air ambient of 80ºC.
The test sample is pre-production without serial number.
Instructions and equipment marking related to safety is applied in the language that is acceptable in the country in which the equipment is to be sold.
Page 4 of 54 Report No.:L651721L215
Sporton International Inc.
Clause Requirement - Test Result - Remark Verdict
1 GENERAL Pass
1.5 Components Pass
1.5.1 Comply with IEC 60950-1 or relevant component standard
Components, which were found to affect safety aspects, comply with the requirements of this standard or with the safety aspects of the relevant IEC/EN component standards.
Pass
1.5.2 Evaluation and testing of components Components, which are certified to IEC/EN and/or national standards, are used correctly within their ratings or have been evaluated during this approval.
Pass
1.5.3 Thermal controls N.A.
1.5.4 Transformers N.A.
1.5.5 Interconnecting cables N.A.
1.5.6 Capacitors bridging insulation N.A.
1.5.7 Resistors bridging insulation N.A.
1.5.7.1 Resistors bridging functional, basic or supplementary insulation
N.A.
1.5.7.2 Resistors bridging double or reinforced insulation between a.c. mains and other circuits
N.A.
1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable
N.A.
1.5.8 Components in equipment for IT power systems N.A.
1.5.9 Surge suppressors N.A.
1.5.9.1 General N.A.
1.5.9.2 Protection of VDRs N.A.
1.5.9.3 Bridging of functional insulation by a VDR N.A.
1.5.9.4 Bridging of basic insulation by a VDR N.A.
1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR
N.A.
1.6 Power interface N.A.
1.6.1 AC power distribution systems ............................. : N.A.
1.6.2 Input current The equipment is intended for building-in, in compliance with the requirement shall be evaluated in end product.
N.A.
1.6.3 Voltage limit of hand-held equipment N.A.
Page 5 of 54 Report No.:L651721L215
Sporton International Inc.
1.6.4 Neutral conductor N.A.
1.7 Marking and instructions Pass
1.7.1 Power rating and identification markings See below. Pass
1.7.8.3 Symbols according to IEC 60417 ........................... : N.A.
1.7.8.4 Markings using figures ......................................... : N.A.
1.7.9 Isolation of multiple power sources ....................... : N.A.
1.7.10 Thermostats and other regulating devices N.A.
1.7.11 Durability The label was subjected to the permanence of marking test. The label was rubbed with cloth soaked with water for 15s and then again for 15s with the cloth soaked with petroleum spirit.
After test, there was no damage to the label. The marking on the label did not fade. There was neither curling nor lifting of the label edge.
Pass
1.7.12 Removable parts ....................................................: N.A.
1.7.13 Replaceable batteries N.A.
Language(s)
1.7.14 Equipment for restricted access locations N.A.
2 PROTECTION FROM HAZARDS Pass
2.1 Protection from electric shock and energy hazards
The equipment is intended for building-in, in compliance with the requirement shall be evaluated in end product.
N.A.
2.1.1 Protection in operator access areas N.A.
2.1.1.1 Access to energized parts N.A.
Test by inspection ................................................. : N.A.
Test with test finger (Figure 2A) ............................ : N.A.
Test with test pin (Figure 2B) .................................... : N.A.
Test with test probe (Figure 2C) ............................ : N.A.
4.6.4.2 Evaluation measures for larger openings N.A.
4.6.4.3 Use of metallized parts N.A.
4.6.5 Adhesives for constructional purposes N.A.
Conditioning temperature (ºC) / time (weeks)
4.7 Resistance to fire Pass
4.7.1 Reducing the risk of ignition and spread of flame See below. Pass
Method 1, selection and application of components wiring and materials
Use of materials with the required flammability Classes.
Pass
Method 2, application of all of simulated fault condition tests
N.A.
4.7.2 Conditions for a fire enclosure The equipment is intended for building-in, in compliance with the requirement shall be evaluated in end product.
N.A.
4.7.2.1 Parts requiring a fire enclosure N.A.
4.7.2.2 Parts not requiring a fire enclosure N.A.
4.7.3 Materials See below. Pass
4.7.3.1 General PWB rated V-1 minimum. Pass
4.7.3.2 Materials for fire enclosures N.A.
4.7.3.3 Materials for components and other parts outside fire enclosures
N.A.
4.7.3.4 Materials for components and other parts inside fire enclosures
N.A.
4.7.3.5 Materials for air filter assemblies N.A.
4.7.3.6 Materials used in high-voltage components N.A.
5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass
5.1 Touch current and protective conductor current N.A.
5.1.1 General Class III equipment. N.A.
5.1.2 Equipment under test (EUT) N.A.
5.1.2.1 Single connection to an a.c. mains supply N.A.
5.1.2.2 Redundant multiple connections to an a.c. mains supply
N.A.
5.1.2.3 Simultaneous multiple connections to an a.c. mains supply
N.A.
5.1.3 Test circuit N.A.
5.1.4 Application of measuring instrument N.A.
Page 18 of 54 Report No.:L651721L215
Sporton International Inc.
5.1.5 Test procedure N.A.
5.1.6 Test measurements N.A.
Supply voltage (V) .............................................. :
Measured touch current (mA) ............................... :
Max. allowed touch current (mA) .......................... :
Measured protective conductor current (mA) ...... :
Max. allowed protective conductor current (mA) ... : N.A.
5.1.7 Equipment with touch current exceeding 3.5 mA : N.A.
5.1.7.1 General .................................................................... : N.A.
5.1.7.2 Simultaneous multiple connections to the supply N.A.
5.1.8 Touch currents to and from telecommunication networks and cable distribution systems and from telecommunication networks
N.A.
5.1.8.1 Limitation of the touch current to a telecommunication network and a cable distribution system
N.A.
Supply voltage (V) ................................................. :
Measured touch current (mA) ............................... :
Max. allowed touch current (mA) ............................ :
5.1.8.2 Summation of touch currents from telecommunication networks .................................. :
N.A.
a) EUT with earthed telecommunication ports ........ : N.A.
b) EUT whose telecommunication ports have no reference to protective earth
N.A.
5.2 Electric strength N.A.
5.2.1 General N.A.
5.2.2 Test procedure N.A.
5.3 Abnormal operating and fault conditions Pass
5.3.1 Protection against overload and abnormal operation
See below. Pass
5.3.2 Motors N.A.
5.3.3 Transformers N.A.
5.3.4 Functional insulation ............................................ : Functional Insulation complies with the requirements c).
Pass
5.3.5 Electromechanical components N.A.
5.3.6 Audio amplifiers in ITE N.A.
Page 19 of 54 Report No.:L651721L215
Sporton International Inc.
5.3.7 Simulation of faults All components (which might be flammable) were mounted on a V-1 PCB. All circuits are SELV, so no concerns with electric shock hazard. Besides, inspection of thermal hazard (e.g. extreme heat) is dependent on final configuration, so recommended to be performed at the end product.
N.A.
5.3.8 Unattended equipment N.A.
5.3.9 Compliance criteria for abnormal operating and fault conditions
N.A.
5.3.9.1 During the tests N.A.
5.3.9.2 After the tests N.A.
6 CONNECTION TO TELECOMMUNICATION NETWORKS N.A.
6.1 Protection of telecommunication network service personnel, and users of other
equipment connected to the network, from hazards in the equipment
N.A.
6.1.1 Protection from hazardous voltages N.A.
6.1.2 Separation of the telecommunication network from earth N.A.
6.1.2.1 Requirements N.A.
Supply voltage (V) ...............................................:
Current in the test circuit (mA) .............................. :
6.2 Protection of equipment users from overvoltages on telecommunication networks N.A.
6.2.1 Separation requirements N.A.
6.2.2 Electric strength test procedure N.A.
6.2.2.1 Impulse test N.A.
6.2.2.2 Steady-state test N.A.
6.2.2.3 Compliance criteria N.A.
6.3 Protection of telecommunication wiring system from overheating N.A.
Max. output current (A) ........................................ :
Current limiting method ........................................... :
7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N.A.
7.1 General N.A.
7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment
N.A.
Page 20 of 54 Report No.:L651721L215
Sporton International Inc.
7.3 Protection of equipment users from overvoltages on the cable distribution system
N.A.
7.4 Insulation between primary circuits and cable distribution systems
N.A.
7.4.1 General N.A.
7.4.2 Voltage surge test N.A.
7.4.3 Impulse test N.A.
A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N.A.
A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 Kg, and of stationary equipment (see 4.7.3.2)
A.1.2 Conditioning of samples; temperature (C) ............ : N.A.
A.1.3 Mounting of samples ............................................... : N.A.
A.1.4 Test flame (see IEC 60695-11-3) N.A.
Flame A, B, C or D .................................................. : N.A.
A.1.5 Test procedure N.A.
A.1.6 Compliance criteria N.A.
Sample 1 burning time (s) .................................... :
Sample 2 burning time (s) ....................................... :
Sample 3 burning time (s) ....................................... :
A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 Kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4)
Delete all the “country” notes in the reference document (IEC 60950-1:2005/A1:2010) according to the following list:
1.5.7.1 Note 6.1.2.1 Note 2
6.2.2.1 Note 2 EE.3 Note
P
General
(A2:2013)
Delete all the “country” notes in the reference document (IEC 60950-1:2005/A2:2013) according to the following list: 2.7.1 Note * 2.10.3.1 Note 2
6.2.2. Note * Note of secretary: Text of Common Modification remains unchanged.
N/A
1.1.1(A1:2010) Replace the text of NOTE 3 by the following
NOTE3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN 60065 applies.
N/A
Page 37 of 54 Report No.:L651721L215
Sporton International Inc.
1.3.Z1 Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers.
N/A
(A12:2011) In EN 60950-1:2006/A12:2011
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006 /A1:2010
N/A
1.5.1 (Added info*)
Add the following NOTE:
NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC. New Directive 2011/65/11 *
N/A
1.7.2.1
(A1:2010)
In addition, for a PORTABLE SOUND SYSTEM, the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss.
N/A
1.7.2.1
(A12.2011)
In EN 60950-1:2006/A12:2011
Delete NOTE Z1 and the addition for Portable Sound System.
Add the following clause and annex to the existing standard and amendments.
N/A
Zx Protection against excessive sound pressure from personal music
players
N/A
Zx.1 General N/A
Page 38 of 54 Report No.:L651721L215
Sporton International Inc.
This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players.
A personal musifor personal use, that:
is designed to allow the user to listen to recorded or broadcast sound or video; and
primarily uses headphones or earphones that can be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD players, MP3 audio players, mobile phones with MP3 type features, PDA’s or similar equipment.
A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause.
The requirements in this sub-clause are valid for music or video mode only.
The requirements do not apply:
while the personal music player is connected to an external amplifier; or
while the headphones or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player.
The requirements do not apply to:
hearing aid equipment and professional equipment;
NOTE 3 Professional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment.
Page 39 of 54 Report No.:L651721L215
Sporton International Inc.
analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies.
For equipment which is clearly designed or intended for use by young children, the limits of EN 71-1 apply.
Zx.2 Equipment requirements
No safety provision is required for equipment that complies with the following:
equipment provided as a package (personal music player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured while playing the fixed “programme simulation noise” as described in EN 50332-1; and
a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is ≤ 27 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level LAeq,T is meant. See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and
b) have a standard acoustic output level not exceeding those mentioned above, and
automatically return to an output level not exceeding those mentioned above when the power is switched off; and
N/A
Page 40 of 54 Report No.:L651721L215
Sporton International Inc.
c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals. Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with Its listening device), the acoustic output shall be ≤ 100 dBA measured while playing the fixed “programme simulation noise” described in EN 50332-1; and
2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be ≤ 150 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” described in EN 50332-1.
For music where the average sound pressure (long term LAeq,T) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. In this case T becomes the duration of the song.
NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA.
For example, if the player is set with the programme simulation noise to 85 dBA, but the average music level of the song is only 65 dBA, there is no need to give a warning or ask an acknowledgement as long as the average sound leve
Page 41 of 54 Report No.:L651721L215
Sporton International Inc.
Zx.3 Warning
The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following:
the symbol of Figure 1 with a minimum height of 5 mm; and
the following wording, or similar:
“To prevent possible hearing damage, do not listen at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level.
N/A
Zx.4 Requirements for listening devices (headphones and earphones) N/A
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the input voltage of the fixed “programme simulation noise” described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where the headphones can operate (active or
passive), including any available setting (for example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 27 mV and 100 dBA – 150 mV.
N/A
Page 42 of 54 Report No.:L651721L215
Sporton International Inc.
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed “programme simulation noise” described in EN 50332-1 (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA.
This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.).
NOTE An example of a wired listening device with digital input is a USB headphone.
N/A
Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing the fixed programme simulation noise described in EN 50332-1; and
respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and
with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the abovementioned programme simulation noise, the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA.
NOTE An example of a wireless listening device is a Bluetooth headphone.
N/A
Zx.5 Measurement methods
Measurements shall be made in accordance with EN 50332-1 or EN 50332-2 as applicable. Unless stated otherwise, the time interval T shall be 30 s.
NOTE Test method for wireless equipment provided without listening device should be defined.
N/A
Page 43 of 54 Report No.:L651721L215
Sporton International Inc.
2.7.1 Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits and earth faults in PRIMARY CIRCUITS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions.
If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet.
N/A
2.7.2 This subclause has been declared ‘void’. N/A
3.2.3 Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in parentheses.
N/A
3.2.5.1 Replace “60245 IEC 53” by “H05 RR-F”; “60227 IEC 52” by “H03 VV-F or H03 VVH2-F”; “60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”.
In Table 3B, replace the first four lines by the following:
| Up to and including 6 | 0,75 a)
| | Over 6 up to and including 10 | (0,75)
b) 1,0
| | Over 10 up to and including 16 | (1,0) c) 1,5 |
In the conditions applicable to Table 3B delete the words “in some countries” in condition
a).
In NOTE 1, applicable to Table 3B, delete the second sentence.
N/A
3.2.5.1 (A2:2013)
NOTE Z1 The harmonised code designations corresponding to the IEC cord types are given in Annex ZD
N/A
Page 44 of 54 Report No.:L651721L215
Sporton International Inc.
3.3.4 In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following:
| Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4 |
Delete the fifth line: conductor sizes for 13 to 16 A.
N/A
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artifical optical radiation).
N/A
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artifical optical radiation).
N/A
Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC.
N/A
Annex H Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
N/A
Bibliography Additional EN standards. N/A
ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS
ZB SPECIAL NATIONAL CONDITIONS N/A
1.2.4.1 In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets.
N/A
1.2.13.14(A1
1:2009) In Norway and Sweden, for requirements see 1.7.2.1 and 7.3 of this annex.
N/A
Page 45 of 54 Report No.:L651721L215
Sporton International Inc.
1.5.7.1(A11:2
009) In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1.5.7. 1. In addition when a single resistor is used, the resistor must withstand the resistor test in 1.5.7.2.
N/A
1.5.8 In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V).
N/A
1.5.9.4 In Finland, Norway and Sweden, the third dashed sentence is applicable only to equipment as defined in 6.1.2.2 of this annex.
N/A
Page 46 of 54 Report No.:L651721L215
Sporton International Inc.
1.7.2.1 (A11:2009)
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
In Norway and Sweden, the screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building. Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system.
It is however accepted to provide the insulation external to the equipment by an adapter or an interconnection cable with galvanic isolator, which may be provided by e.g. a retailer.
The user manual shall then have the following or similar information in Norwegian and Swedish language respectively, depending on in what country the equipment is intended to be used in:
”Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing – and to a cable distribution system using coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has therfore to be provided through a device providing electrical isolation below a certain frequency range (galvanic isolator, see EN 60728-11).”
NOTE In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1.5 kV r.m.s., 50 Hz or 60 Hz, for 1min.
Translation to Norwegian (the Swedish text will also be accepted in Norway):
”Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är
N/A
Page 47 of 54 Report No.:L651721L215
Sporton International Inc.
1.7.2.1 (A2:2013)
In Denmark, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.”
N/A
1.7.5 In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b or DK 1-5a.
N/A
1.7.5 (A2:2013)
In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the DS 60884-2-D1:2011.
For class I equipment the following Standard Sheets are applicable: DK 1-3a, DK 1-1c, DK 1-1d, DK 1-5a or DK 1-7a, with the exception for STATIONARY EQUIPMENT where the socket-outlets shall be in accordance with Standard Sheet DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class II apparatus with a rated current of 2,5 A shall be in accordance with DS 60884-2-D1 standard sheet DKA 1-4a. Other current rating socket outlets shall be in compliance with by DS 60884-2-D1 Standard Sheet DKA 1-3a or DKA 1-3b.
Justification the Heavy Current Regulations, 6c
N/A
2.2.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.2 In Finland, Norway and Sweden there are additional requirements for the insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.4 In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.6.3.3 In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 16 A.
N/A
2.7.1 In the United Kingdom, to protect against excessive currents and short-circuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met.
N/A
Page 48 of 54 Report No.:L651721L215
Sporton International Inc.
2.10.5.13 In Finland, Norway and Sweden, there are additional requirements for the insulation, see 6.1.2.1 and 6.1.2.2 of this annex.
N/A
3.2.1.1 In Switzerland, supply cords of equipment having a RATED CURRENT not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 60884-1 and one of the following dimension sheets:
SEV 6532-2.1991 Plug Type 15 3P+N+PE 250/400 V, 10 A SEV 6533-2.1991 Plug Type 11 L+N 250 V, 10 A SEV 6534-2.1991 Plug Type 12 L+N+PE 250 V, 10 A
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 A plug and socket-outlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998:
SEV 5932-2.1998 Plug Type 25 3L+N+PE 230/400 V, 16 A SEV 5933-2.1998 Plug Type 21 L+N 250 V, 16 A SEV 5934-2.1998 Plug Type 23 L+N+PE 250 V, 16 A
N/A
Page 49 of 54 Report No.:L651721L215
Sporton International Inc.
3.2.1.1 In Denmark, supply cords of single-phase equipment having a rated current not exceeding13 A shall be provided with a plug according to the Heavy Current Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug, this plug shall be in accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
N/A
3.2.1.1 (A2:2013)
In Denmark, supply cords of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to DS 60884-2-D1.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED CURRENT exceeding 13 A or if a poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with the standard sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2.
Justification the Heavy Current Regulations, 6c
N/A
3.2.1.1 In Spain, supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN 60309-2.
N/A
Page 50 of 54 Report No.:L651721L215
Sporton International Inc.
3.2.1.1 In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug.
N/A
3.2.1.1 In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations 1997.
N/A
3.2.4 In Switzerland, for requirements see 3.2.1.1 of this annex.
N/A
3.2.5.1 In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A.
N/A
3.3.4 In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is:
• 1,25 mm2 to 1,5 mm
2 nominal cross-sectional area.
N/A
Page 51 of 54 Report No.:L651721L215
Sporton International Inc.
4.3.6 In the United Kingdom, the torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, except that the test of 12.17 is performed at not less than 125 °C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply.
N/A
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526:1997 - National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, 1997.
N/A
5.1.7.1 In Finland, Norway and Sweden TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that ○ is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, for example, in a telecommunication centre; and ○ has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR; and ○ is provided with instructions for the installation of that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE B;
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT.
N/A
Page 52 of 54 Report No.:L651721L215
Sporton International Inc.
6.1.2.1 (A1:2010)
In Finland, Norway and Sweden, add the following text between the first and second paragraph of the compliance clause:
If this insulation is solid, including insulation forming part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which shall pass the electric strength test below, or
- one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below.
Alternatively for components, there is no distance through insulation requirements for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition
- passes the tests and inspection criteria of 2.10.11 with an electric strength test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kV.
It is permitted to bridge this insulation with an optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a capacitor complying with EN 60384-14:2005, subclass Y2.
A capacitor classified Y3 according to EN 60384-14:2005, may bridge this insulation under the following conditions:
- the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 60384-14, which in addition to the Y3 testing, is tested with an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the test specimens as described in EN 60384-14;
- the impulse test of 2,5 kV is to be performed before the endurance test in EN 60384-14, in the sequence of tests as described in EN 60384-14.
N/A
6.1.2.2 In Finland, Norway and Sweden, the exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON.
N/A
Page 53 of 54 Report No.:L651721L215
Sporton International Inc.
7.2 In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this annex.
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term CABLE DISTRIBUTION SYSTEM.
N/A
7.3 (A11:2009)
In Norway and Sweden, for requirements see 1.2.13.14 and 1.7.2.1 of this annex. N/A
Page 54 of 54 Report No.:L651721L215
Sporton International Inc.
Annex ZD
(informative)
IEC and CENELEC code designations for flexible cords