LVD Light 200 watt ( AC ) Structure
LVD Advantages
Unique and special coil ring structure
Protective cover in amalgam tube
Special design for exhaust tube
Over-bridge structure
Special Electronic Ballast Dimming Technology
Patented Venus lamp
Patented Self-ballasted Saturn 2B lamp type with dimming capacity
Biological lighting system and germicidal lighting
Firstly apply induction lamp in solar lighting system
Universal Ballast Digital lighting control system
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
2/19
LVD Light 200 watt ( AC ) Structure
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
3/19
LVD Light 200 watt ( AC ) Compare w/ Another Lamp
LVD Lamp 200 wattstarting position
LVD Lamp 200 wattafter 15 minutes
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
4/19
LVD Light 200 watt ( AC ) Compare w/ Another Lamp
Mercury Lamp 250 watt
LHE Lamp 85 watt
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
5/19
LVD Light 200 watt ( AC ) Compare w/ Another Lamp
No. Specification
LVD Lamp 200 watt
..starting ..after
15 minutes
Mercury
Lamp
250 watt
LHE
CFL Lamp
85 watt
1. Voltage 205.1 V 206.9 V 208.3 V 200.9 V
2. Current 0.746 A 0.588 A 1.678 A 0.525 A
3. Power 151.6 W 119.9 W 208.3 W 65.1 W
4. Power Factor 0.990 PF 0.982 PF 0.596 PF 0.617 PF
5.LampOperating
Temperature
< 26.6 C ( 80F ) 250 C 90 C
6. Starting ON Direct -Takes 10 30
minutes tomaximum
Direct
7.
After OFF toON
( Re-strike )Direct -
Takes 10 30
minutes tomaximum
Direct
8.Lumen 20,000 11,000 4,250
Lumen/watt 100 44 50
9. Lux on Ground 8 m ( lux 100 )6 m ( lux 220 )
10.ColorTemperature
6500K Full Range 4000K 2700K
11. Life Hours >100,000hrs 18,000hrs 8,000hrs
12. Efficacy >80lm/w
13.ColorRendering
Index ( CRI )
>80Ra 20Ra >80Ra
14.
Lumen
DepreciationRate
5% (2,000hrs) 40% (2,000hrs) 30% (2,000hrs)
15. Heat Output Very Low Very High Very Low
16. Light Fitting Easy to Accommodate
17.Liner LightSource
No Glare, No Flicker,Good Visual Effect
Much Flicker,Much Glare
Much Flicker,Much Glare
18. Cover Area 70 m2
19. Environmental No MercuryContainsmercury
Containsmercury
20. Safety No lamp waste in 10 years waste over 10years waste over 10years
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
6/19
LVD Light 200 watt ( AC ) Compare w/ Another Lamp
Comparison
programLVD LED
Feature Define
Low Voltage Discharge
Liner light. Good for large wattage
application.
Lighting Emit Diode
Spot light. Usually for signboard, decoration
applications.
Technology
Research and develop in 2000, sellin 2003,in a position of new leading
light source. Standardized product
can fully meet the market need,
suitable for large scale production.
The first red light LED was developed in1968.Since then, its been 40 years. The first
white light LED was in 1996.Invest risk high for
technology update too fast. Not suitable for
functional lighting project. The whole growing
process is slow.
Market potential
LVD can replace most of
conventional light sources in
functional lighting fields, so its
potential market is huge.
LED has developed for many years, but limited
to traffic signal, vehicle rear light, LCD panel
back lighting, display in lower wattage because
of the low light efficiency, low power factor,
scarcity of accommodated fittings.
Economy
With the development of large scale
production, LVD cost will be
lowered to the same level of
traditional lights or even lower, then
it will be widely used.
High cost, difficult to be widely used in some
fields, limited in certain market.
Energy saving
LVD efficacy is as 30% as higher
than LED, with lower depreciation.
Lower efficacy, lower power factor, high
depreciation and heat output, not as saving as
LVD. Semi-conductor technology consumes
more energy during production.
Application
Industrial, commercial, street,
tunnel, bridge, garden, agriculture,
Ad.
Traffic signal, vehicle rear lights, cell phone
display screen etc. Limited in functional lighting
projects.
Reference
LVD has been widely used in
various lighting projects. It is proved
that LVD has big market potential,
industrialization speed with scale
effect.
LED is drawn back by its technological
problems. Probably another 5-10 years to go
before it is industrialized and scaled.
Technical data
1. Power: 15~300W2.
Efficacy: >80lm/w3. CRI: >80Ra
4. Color temperature:2100K~6500K full range
5. Depreciation:5%2000hrs
6. Life:>100,000hrs7. Heat output: very low8. Light fitting: easy to
accommodate
9. Liner light source: no glare,no flicker, good visual effect.
1. Each 0.5~1W, more than 100 needed forlarge wattage.2. Efficacy: 80Ra4. Color temperaturenarrow range(white
light LED)
5. Light attenuation: >50%(2000 hours)6. Service life:
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
7/19
LVD Light 200 watt ( AC ) Compare w/ Another Lamp
Berdasarkan perhitungan pada table diatas dapat dilihat dengan jelas bahwa pemakaian Lampu LVD lebih
hemat dibandingkan dengan Lampu Metal Halide, juga lampu-lampu lainnya.
Semua perbandingan dapat dihitung dengan jelas dengan data-data yang lengkapjadi untuk perhitungan
effisiensi biaya perusahaan sangatlah bijaksana apabila menggunakan Lampu Induksi LVD!
Perbandingan PenghematanLampu LVD Metal Halide
Lighting System Unit LVD 80W HPI-T 250WNumber of Luminaires pcs 59.00 59.00
Number of lamps per luminaire pcs 1.00 1.00
Configuration W 80W 250W
Circuit wattage per luminaire W 81W 266W
Aircon loading per luminaire W 1.00 50.00Total circuit wattage per luminaire W 81.00 316.00
Estimated Annual hours burned hrs 4,320.00 4,320.00
Total circuit wattage kW 4.78 18.64
Annual energy consumed kWh 20,645.28 80,542.08
Economic lamp life (80% inst. luminaire flux) hrs 100,000.00 8,000.00
Annual energy costs Rp 26,838,864.00 104,704,704.00
Annual lamp costs Rp 0.00 0.00
Annual operating costs Rp 0.00 0.00
Annual savings Rp 77,865,840.00 0.00
Saving as % of conv. operation cost % 74.37 0.00
Life Hours hrs 100,000 6,000~20,000
Lumen Photopic Efficacy Plm/W 150 110
Plm: Pupil Lumen ( Traditional Efficacy ) Lm/W 80 75
Lumen Depreciation Rate % hrs 5% ( 2,000 hrs ) 40% ( 2,000 hrs )
Lamp Operating Temperature C < 26.6 C ( 80F ) > 148.8 C ( 300F )
Color Rendering Index ( CRI ) Ra >80 (Ra) 65~80 (Ra)
Re-strike InstantNeeds up to 10~15
minutes
Flicker, Glare None MuchEnviromental No Mercury Contains Mercury
SafetyNo lamp waste in 10
yearsWaste over 10 years
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
8/19
LVD Light 200 watt ( AC ) on Site
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
9/19
LVD Light 200 watt ( AC ) at Billboard Robotic Trading Biliton
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
10/19
LVD Light 200 watt ( AC ) at Billboard Yaris 0309
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
11/19
LVD Light 200 watt ( AC ) at Manado, September 2011
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
12/19
LVD Light 200 watt ( AC ) at STIKOM, June 2011
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
13/19
LVD Light 200 watt ( AC ) at STIKOM, June 2011
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
14/19
LVD Light 200 watt ( AC ) at Chiel Jedang Samsung
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
15/19
LVD Light 200 watt ( AC ) for Minyak Goreng Warehouse
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
16/19
LVD Light 200 watt ( AC ) at PT. Hansa Pratama LVD vs Mercury / HPIT
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
17/19
LVD Light 200 watt ( AC ) on Another Application
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
18/19
LVD Light 200 watt ( AC ) on Another Application
7/30/2019 LVD Light 200 Watt ( AC ) Complete via Email
19/19
LVD Light 200 watt ( AC ) at PT. SANTOS Kapal Api