    2/16

    SmartStep - Option

    Provides in room viewing and scan control for

    interventional CT procedures. This package includes an in

    room monitor for reviewing of images, a hand held remotecontroller for system manipulation and a foot switch to

    initiate exposure.

  • 7/30/2019 ls2002_smartstep

    3/16

    LightSpeed LS2002SmartStep Workflow scenario

    Position patient on CT cradle and acquire a scoutfor area of interest

    Perform localizing images to determine biopsy

    location Mark patient skin for needle entrance point

    Launch SmartStep to perform actual biopsy

    procedureOnce you are in SmartStep mode all other desktops are

    locked out (Image Works, Learning Solutions, etc..)

  • 7/30/2019 ls2002_smartstep

    4/16

    SmartStep Option

    - Handheld Controller provides in room controls for scanning

    and image review.

    - Connection port is provided on either side of the rear of the

    gantry for foot exposure switch and handheld controller.

    - Base plate for the cradle to attach handheld controller and

    cradle handle.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    5/16

    SmartStep - Option

    LightSpeed LS2002

    Prep Button

    Disabled

    Cradle Move IN

    Change Focus

    Prior Image

    W/L Toggle

    Handheld Controller

    Cradle Move Out

    Alignment Light

    Move to Start Loc

    Bump OutBump In

    Cradle Latch/

    Unlatch

    Next Image

  • 7/30/2019 ls2002_smartstep

    6/16

    SmartStep Option

    LightSpeed LS2002

    Foot Exposure

    SwitchHandheld

    Controller

    Connection Ports on Rear of Gantry

  • 7/30/2019 ls2002_smartstep

    7/16

    SmartStep Option

    Can be launched by two different methods:From Create New Series

    From Dynaplan Screen

    LightSpeed LS2002

    SmartStep can not be built into a protocol

  • 7/30/2019 ls2002_smartstep

    8/16

    SmartStep - Option- Available Slice Thickness of 2.5, 5 and 7.5mm.

    - mA values typically range from 20 to 40 mA for Chest,

    30-80 mA for Abdomen

    LightSpeed LS2002

    -Time to first image is 5 sec. after foot pedal is released

    -Matrix size of 512 is standard

    Bump Distance defaults to of slice thickness

  • 7/30/2019 ls2002_smartstep

    9/16

    SmartStep - Option- 0.8 and 1 sec full rotation times supported in

    SmartStep.

    - All algorithms are supported.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    10/16

    SmartStep - Option- SmartStep left monitor user interface.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    11/16

    SmartStep - Option- Other desktops unavailable while SmartStep is active.

    - Recon state listed as SmartStep.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    12/16

    SmartStep - Option- Select Prep on left head or on Hand Controller to bring

    system to ready state.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    13/16

    SmartStep - Option- After each rotation, user must release foot peddle before

    you scan again.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    14/16

    SmartStep - Option- Basic image review functions available.

    -Maintain -keeps measurements, ROIs &

    image manipulations (FLR, FTB, etc)throughout the exam

    - List/Select to select series for Free Viewport.

    - Forward/Backward 1 functionality dependson focus. Free Viewport is 1 image.

    Interventional View-ports will move as a set of

    3 images.

    - Images in interventional viewport displayed

    superior to inferior in location.

    LightSpeed LS2002

    See the Learning Solutions operator documentation for acomplete description of SmartStep functionality

  • 7/30/2019 ls2002_smartstep

    15/16

    SmartStep - Option- Preset Window /Level preferences screen for SmartStep

    available under Display Preferences on ExamRx Display

    desktop.

    LightSpeed LS2002

  • 7/30/2019 ls2002_smartstep

    16/16

    SmartStep - Option

    LightSpeed LS2002

    Image 1 Image 2 Image 3

    Free Viewport