L:Projects73-12144 …PDFs/Google...DNUP UP DN DN UP UP UP UP UP DN UP DN UP DN U 1 2 3 4 7 8 9 10 A B E F G H J K L M N P R S T 11 5 6 12 C D Q 229' TO EXIT EXIT EXIT 197' TO EXIT
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
DNUP
UP
DN
DN
UP
DN
DNUP
DN
UP
UP UP
UPUP
UP UPUP
DN
UPDN
UPDN
UPDN
UP
DN
UPDN
U
1
2
3
4
7
8
9
10
A B E F G H J K L M N P R S T
11
5
6
12
DC Q
229'
TO E
XIT
EXIT
EXIT
197'
TO E
XIT
164170
328350
164170
VAN
VAN
VAN
U
1
2
3
4
7
8
9
10
A B E F G H J K L M N P R S T
11
5
6
12
DC Q
EXIT
303'
TO E
XIT
240'
TO E
XIT
EXIT
167
170 167
350
167
170
- COMBINED OCCUPANT LOAD AT A GIVEN EXIT DOOR. (SUM OFTHESE EQUALS TOTAL OCCUPANT LOAD)
(OCCUPANCY LOAD IS NOT INCLUDED IN LOADS BEYOND THIS ROOM)
- COMBINED OCCUPANT LOAD AT A GIVEN DOOR OR STAIR
2-HOUR RATING
- TOTAL EXIT CAPACITY OF DOOR (THE CAPACITY OF DOORSARE DETERMINED AS FOLLOWS: CLEAR OPENING WIDTH ININCHES DIVIDED BY 0.2)
WALL RATING LEGEND
1-HOUR RATING
SYMBOL LEGEND- OCCUPANCY LOAD####
00
###
PD60 MIN
- PANIC DEVICE
- TOTAL EXIT CAPACITY OF DOOR OR STAIR (THE CAPACITY OFDOORS ARE DETERMINED AS FOLLOWS: CLEAR OPENING WIDTHIN INCHES DIVIDED BY 0.2THE CAPACITY OF STAIRS ARE DETERMINED AS FOLLOWS:WIDTH IN INCHES DIVIDED BY 0.3)
LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET
BEN
JAM
IN T
ALPO
S
Revis
i ons
DE
NORTH
F
6/20
/201
3 11
:28:
22 A
M
C:\@
Rev
it\G
oogl
e\G
oogl
e Ph
ase
II Sh
ell a
nd C
ore_
Jam
es_A
R_2
012.
rvt
73-1
2144
-00
06.2
0.13
SRM
KII D
EVEL
OPM
ENT
PERM
IT S
ETFI
RST
FLO
OR
PLA
N -
BUIL
DIN
G D
A1.1
D
2012
PAC
E SI
TE
SCALE: 3/32" = 1'-0"A1.1D
1 BUILDING D - FIRST FLOORNORTH
1 EDIT TEXT HERE2 EDIT TEXT HERE3 GLASS RAIL TOP AT PARTIAL HEIGHT WALL4 FULL HEIGHT GLASS RAIL5 STEEL ROD INFILL RAIL6 EDIT TEXT HERE7 EDIT TEXT HERE8 EDIT TEXT HERE9 EDIT TEXT HERE10 EDIT TEXT HERE
LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET
BEN
JAM
IN T
ALPO
S
Revis
i ons
DE
NORTH
F
6/20
/201
3 11
:14:
53 A
M
C:\@
Rev
it\G
oogl
e\G
oogl
e Ph
ase
II Sh
ell a
nd C
ore_
Jam
es_A
R_2
012.
rvt
73-1
2144
-00
06.2
0.13
SRM
KII D
EVEL
OPM
ENT
PERM
IT S
ETFI
RST
FLO
OR
PLA
N -
BUIL
DIN
G E
A1.1
E
2012
PAC
E SI
TE
SCALE: 3/32" = 1'-0"A1.1E
1 BUILDING E - FIRST FLOORNORTH
1 EDIT TEXT HERE2 EDIT TEXT HERE3 GLASS RAIL TOP AT PARTIAL HEIGHT WALL4 FULL HEIGHT GLASS RAIL5 STEEL ROD INFILL RAIL6 EDIT TEXT HERE7 EDIT TEXT HERE8 EDIT TEXT HERE9 EDIT TEXT HERE10 EDIT TEXT HERE
LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET
BEN
JAM
IN T
ALPO
S
Revis
i ons
DE
NORTH
F
6/20
/201
3 11
:14:
59 A
M
C:\@
Rev
it\G
oogl
e\G
oogl
e Ph
ase
II Sh
ell a
nd C
ore_
Jam
es_A
R_2
012.
rvt
73-1
2144
-00
06.2
0.13
SRM
KII D
EVEL
OPM
ENT
PERM
IT S
ETSE
CO
ND
FLO
OR
PLA
N -
BUIL
DIN
G D
A1.2
D
2012
PAC
E SI
TE
SCALE: 3/32" = 1'-0"A1.2D
1 BUILDING D - UPPER LEVELNORTH
1 EDIT TEXT HERE2 EDIT TEXT HERE3 GLASS RAIL TOP AT PARTIAL HEIGHT WALL4 FULL HEIGHT GLASS RAIL5 STEEL ROD INFILL RAIL6 EDIT TEXT HERE7 EDIT TEXT HERE8 EDIT TEXT HERE9 EDIT TEXT HERE10 EDIT TEXT HERE
LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET
BEN
JAM
IN T
ALPO
S
Revis
i ons
DE
NORTH
F
6/20
/201
3 11
:15:
05 A
M
C:\@
Rev
it\G
oogl
e\G
oogl
e Ph
ase
II Sh
ell a
nd C
ore_
Jam
es_A
R_2
012.
rvt
73-1
2144
-00
06.2
0.13
SRM
KII D
EVEL
OPM
ENT
PERM
IT S
ETSE
CO
ND
FLO
OR
PLA
N -
BUIL
DIN
G E
A1.2
E
2012
PAC
E SI
TE
SCALE: 3/32" = 1'-0"A1.2E
1 BUILDING E - UPPER LEVEL
1 EDIT TEXT HERE2 EDIT TEXT HERE3 GLASS RAIL TOP AT PARTIAL HEIGHT WALL4 FULL HEIGHT GLASS RAIL5 STEEL ROD INFILL RAIL6 EDIT TEXT HERE7 EDIT TEXT HERE8 EDIT TEXT HERE9 EDIT TEXT HERE10 EDIT TEXT HERE
B. MOST ROOF SLOPES ARE CREATED BY SLOPING THE ROOFSTRUCTURE. SEE STRUCTURAL DRAWINGS FOR ELEVATIONSOF THE HIGH AND LOW POINTS TO DETERMINE PROPERTAPER IN INSULATION. SHADED AREAS INDICATE TAPEREDINSULATION. TAPERED INSULATION SHALL PROVIDE AMINIMUM OF 1/4-INCH PER FOOT OF SLOPE TO ROOF DRAINS,UNLESS NOTED OTHERWISE.
C. ALL ROOF CURBS TO BE A MINIMUM OF 8" ABOVEROOFING LEVELS. PROVIDE TAPERED INSULATION ROOFSADDLES AT ROOF CURBS TO PROVIDE APPROPRIATEDRAINAGE.
D. SEE STRUCTURAL FOR FRAMING AROUND ROOFPENETRATIONS.
E. COORDINATE THE SIZE AND LOCATION OF ROOFPENETRATIONS FOR MECHANICAL AND ELECTRICALEQUIPMENT. REFER TO MECHANICAL AND ELECTRICALDRAWINGS FOR PENETRATIONS NOT SHOWN ON THIS SHEET.
F. FLASH DRAINS, CURBS, VENTS AND STACKS PERMANUFACTURER'S RECOMMENDATIONS IF DETAIL NOTSHOWN ON PLANS.
G. NO ROOF PENETRATIONS ALLOWED WITHIN 5'-0" EACHSIDE OF 2-HOUR AREA SEPARATION WALL AND 2-HRFIREWALL. SEE CODE PLAN FOR WALL LOCATIONS.
1 GLASS RAIL TOP AT PARTIAL HT WALL2 GREEN ROOF3 PLANTER BOX4 GLASS RAIL SYSTEM5 FUTURE GAS FIREPLACE (FUTURE T.I.)6 PEDESTAL PAVER SYSTEM TYPE 17 PEDESTAL PAVER SYSTEM TYPE 28 LIGHTING PER ELECTRICAL9 RAISED SEATING PLATFORM10 EDIT TEXT HERE
B. MOST ROOF SLOPES ARE CREATED BY SLOPING THE ROOFSTRUCTURE. SEE STRUCTURAL DRAWINGS FOR ELEVATIONSOF THE HIGH AND LOW POINTS TO DETERMINE PROPERTAPER IN INSULATION. SHADED AREAS INDICATE TAPEREDINSULATION. TAPERED INSULATION SHALL PROVIDE AMINIMUM OF 1/4-INCH PER FOOT OF SLOPE TO ROOF DRAINS,UNLESS NOTED OTHERWISE.
C. ALL ROOF CURBS TO BE A MINIMUM OF 8" ABOVEROOFING LEVELS. PROVIDE TAPERED INSULATION ROOFSADDLES AT ROOF CURBS TO PROVIDE APPROPRIATEDRAINAGE.
D. SEE STRUCTURAL FOR FRAMING AROUND ROOFPENETRATIONS.
E. COORDINATE THE SIZE AND LOCATION OF ROOFPENETRATIONS FOR MECHANICAL AND ELECTRICALEQUIPMENT. REFER TO MECHANICAL AND ELECTRICALDRAWINGS FOR PENETRATIONS NOT SHOWN ON THIS SHEET.
F. FLASH DRAINS, CURBS, VENTS AND STACKS PERMANUFACTURER'S RECOMMENDATIONS IF DETAIL NOTSHOWN ON PLANS.
G. NO ROOF PENETRATIONS ALLOWED WITHIN 5'-0" EACHSIDE OF 2-HOUR AREA SEPARATION WALL AND 2-HRFIREWALL. SEE CODE PLAN FOR WALL LOCATIONS.
1 GLASS RAIL TOP AT PARTIAL HT WALL2 GREEN ROOF3 PLANTER BOX4 GLASS RAIL SYSTEM5 FUTURE GAS FIREPLACE (FUTURE T.I.)6 PEDESTAL PAVER SYSTEM TYPE 17 PEDESTAL PAVER SYSTEM TYPE 28 LIGHTING PER ELECTRICAL9 RAISED SEATING PLATFORM10 EDIT TEXT HERE
KEYNOTE LEGEND
ATTACHMENT 8SEP12-01379PROJECT PLANS
DN
DN
DN
2
3
4
L
M N
5
32A8.2
35A8.2
33A8.2
51A7.3
10A10.1
53A8.5
54A8.5
2
2
2
3
3
3
3
3 1
1
1
1
4
4
4
5
56
7
7
7
8
9
8A10.1
5' - 6"
1 1
1
5' - 6 3/4" 3' - 0 1/4"
+1' - 0"
6A8.5
RAMP UPSLOPE AT 1:12
R100
A. ROOF PLAN NOTES APPLY TO ALL ROOF PLAN SHEETS.
B. MOST ROOF SLOPES ARE CREATED BY SLOPING THE ROOFSTRUCTURE. SEE STRUCTURAL DRAWINGS FOR ELEVATIONSOF THE HIGH AND LOW POINTS TO DETERMINE PROPERTAPER IN INSULATION. SHADED AREAS INDICATE TAPEREDINSULATION. TAPERED INSULATION SHALL PROVIDE AMINIMUM OF 1/4-INCH PER FOOT OF SLOPE TO ROOF DRAINS,UNLESS NOTED OTHERWISE.
C. ALL ROOF CURBS TO BE A MINIMUM OF 8" ABOVEROOFING LEVELS. PROVIDE TAPERED INSULATION ROOFSADDLES AT ROOF CURBS TO PROVIDE APPROPRIATEDRAINAGE.
D. SEE STRUCTURAL FOR FRAMING AROUND ROOFPENETRATIONS.
E. COORDINATE THE SIZE AND LOCATION OF ROOFPENETRATIONS FOR MECHANICAL AND ELECTRICALEQUIPMENT. REFER TO MECHANICAL AND ELECTRICALDRAWINGS FOR PENETRATIONS NOT SHOWN ON THIS SHEET.
F. FLASH DRAINS, CURBS, VENTS AND STACKS PERMANUFACTURER'S RECOMMENDATIONS IF DETAIL NOTSHOWN ON PLANS.
G. NO ROOF PENETRATIONS ALLOWED WITHIN 5'-0" EACHSIDE OF 2-HOUR AREA SEPARATION WALL AND 2-HRFIREWALL. SEE CODE PLAN FOR WALL LOCATIONS.
LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET
BEN
JAM
IN T
ALPO
S
Revis
i ons
6/20
/201
3 11
:17:
36 A
M
C:\@
Rev
it\G
oogl
e\G
oogl
e Ph
ase
II Sh
ell a
nd C
ore_
Jam
es_A
R_2
012.
rvt
73-1
2144
-00
06.2
0.13
SRM
KII D
EVEL
OPM
ENT
PERM
IT S
ETR
OO
F D
ECK
PLAN
A4.
2
2012
PAC
E SI
TE
SCALE: 3/16" = 1'-0"A4.21 ROOF DECK PLAN
1 GLASS RAIL TOP AT PARTIAL HT WALL2 GREEN ROOF3 PLANTER BOX4 GLASS RAIL SYSTEM5 FUTURE GAS FIREPLACE (FUTURE T.I.)6 PEDESTAL PAVER SYSTEM TYPE 17 PEDESTAL PAVER SYSTEM TYPE 28 LIGHTING PER ELECTRICAL9 RAISED SEATING PLATFORM10 EDIT TEXT HERE
KEYNOTE LEGEND
ATTACHMENT 8SEP12-01379PROJECT PLANS
LEVEL 01 (163'-6")100' - 0"
LEVEL 02113' - 0"
ROOF126' - 0"
PARKING LEVEL 280' - 0"
HEIGHT LIMIT (194'-6")132' - 2"
1
PARKING LEVEL 189' - 0"
23478910 56
T.O. MECHANICAL SCREEN136' - 0"
54A7.1
41A7.2
ABE (159-6")97' - 1"
MECHANICAL SCREEN MECHANICAL SCREEN
ACCENT COLORMETAL PANEL
METAL WALL PANEL, TYP.
P1 ENTRANCE GREEN SCREENWALL
METAL WALL PANEL, TYP.
2 2 2 2
2 2 2 14
15131313
13131312 H
H
1A10.7
LEVEL 01 (163'-6")100' - 0"
LEVEL 02113' - 0"
ROOF126' - 0"
HEIGHT LIMIT (194'-6")132' - 2"
A B E F G H J
T.O. MECHANICAL SCREEN136' - 0"
DC
34A7.2
ABE (159-6")97' - 1"
MECHANICAL SCREEN
LIGHT MONITOR
STONE WALL
ACCENT COLORMETAL PANEL
METAL WALL PANEL, TYP.
2 2 1
B C
C 5
5
11
4
LEVEL 01 (163'-6")100' - 0"
LEVEL 02113' - 0"
ROOF126' - 0"
U
HEIGHT LIMIT (194'-6")132' - 2"
K
L
M N P R S T
T.O. MECHANICAL SCREEN136' - 0"
Q
21A7.3
ABE (159-6")97' - 1"
ELEVATOR/STAIR TOWER
MECHANICAL SCREEN
T.O. ELEVATOR145' - 2"
LIGHT MONITOR 22A7.3
51A7.3
STONE WALLSTONE WALL
ACCENT COLORMETAL PANEL
ACCENT COLORMETAL PANEL
ACCENT COLORMETAL PANEL METAL WALL PANEL, TYP.
METAL WALL PANEL, TYP.METAL WALL PANEL, TYP.
METAL WALL PANEL, TYP.METAL WALL PANEL, TYP.
ACCENT COLORMETAL PANEL
6 7D
D E
24
8
2G
9 10 2 11
12
9A10.15
5
ELEVATION KEY NOTES
1 (IG-1) INDICATES LOCATIONS WITH TINTED GLAZING
2 (IG-2) INDICATES LOCATIONS WITH NON-TINTING LOW EGLAZING