3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. N/UK 1.5.149.01 LPDA/182000, LPDA/182000/M Low temperature cylinders with or without magnetic piston Double acting Ø 32 to 125 mm To be suited to -40°C Special polyurethane wiper seal Lightweight profile design with concealed tie rods High corrosion and acid resistant materials Clean line profile design with full machined end covers Technical data Medium: Compressed air, filtered, lubricated or non-lubricated Operation: Double acting, with adjustable cushioning Standard: ISO 6431, VDMA 24562, NFE 49-003-1 Operating pressure: 1 to 10 bar Operating temperature: -40°C to +80°C max. Cylinder diameters: 32, 40, 50, 63, 80, 100 and 125 mm Strokes: Standard, see page 2 Non-standard strokes (10 to 3000 mm) available Materials Profile barrel: clear anodised aluminium End covers: black anodiseed aluminium Piston rod: hart chromium plated stainless steel X10 Cr Ni S 18 9 (AISI 303, 1.4305) Piston rod nut: X10 Cr Ni S 18 9 (AISI 303, 1.4305) Cover screws: X10 Cr Ni S 18 9 (AISI 303, 1.4305) Tie rods: X10CrN, S189 Piston and piston rod seals: polyurethane O-rings: nitrile rubber Mountings See page 3 Ordering examples See page 4 and 5 Switches On request
40
Embed
LPDA/182000, LPDA/182000/M - · PDF fileLPDA/182000, LPDA/182000/M Low temperature cylinders with or without magnetic piston Double acting Ø 32 to 125 mm To be suited to
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.01
LPDA/182000, LPDA/182000/MLow temperature cylinders
with or without magnetic pistonDouble acting
Ø 32 to 125 mm
To be suited to -40°C
Special polyurethane wiper seal
Lightweight profile design with concealed tie rods
High corrosion and acid resistant materials
Clean line profile design with full machined end covers
Technical dataMedium:Compressed air, filtered, lubricated or non-lubricatedOperation:Double acting, with adjustable cushioningStandard:ISO 6431, VDMA 24562, NFE 49-003-1Operating pressure:1 to 10 barOperating temperature:-40°C to +80°C max. Cylinder diameters:32, 40, 50, 63, 80, 100 and 125 mmStrokes:Standard, see page 2Non-standard strokes (10 to 3000 mm) available
MaterialsProfile barrel: clear anodised aluminiumEnd covers: black anodiseed aluminiumPiston rod: hart chromium plated stainless steel X10 Cr Ni S 18 9 (AISI 303, 1.4305)Piston rod nut: X10 Cr Ni S 18 9 (AISI 303, 1.4305)Cover screws: X10 Cr Ni S 18 9 (AISI 303, 1.4305)Tie rods: X10CrN, S189Piston and piston rod seals: polyurethaneO-rings: nitrile rubber
Mountings
See page 3Ordering examples
See page 4 and 5
SwitchesOn request
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
Non-magnetic piston Magnetic pistonPageDescriptionModel Model
WarningThese products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified,for non-industrial applications, life-support systems, or otherapplications not within published specifications, consultNORGREN.Through misuse, age, or malfunction, components used in fluidpower systems can fail in various modes.
The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provideadequate safeguards to prevent personal injury or damage toequipment in the event of such failure.
System designers must provide a warning to end users in thesystem instructional manual if protection against a failuremode cannot be adequately providedSystem designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.
LPDA/182000 LPDA/182000/M Standard cylinders 6
LPDA/182000/JM Standard with double ended piston rod 7
LPDA/182000/MT Four position cylinders 7
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.03
LPDA/182000, LPDA/182000/M
Options selector LPDA/182˙˙˙/˙˙/˙˙˙˙
Stroke10 ... 3000, non-magnetic piston25 ... 3000 magnetic piston
Variants (with switches) SubstituteStandard MDouble ended piston rod JMFour position MTExtended piston rod MULPDA/182***/MU/****/***
Extension (mm)
For combinations of cylinder variantsconsult our »Technical Service«
Ordering ExamplesCylindersTo order a standard 80 mm bore magnetic piston cylinder with a 50 mm strokequote: LPDA/182080/M/50
MountingsTo order a front flange mounting style G for 80 mm bore,stainless steel materialquote: KQA/8080/22
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.05
LPDA/182000, LPDA/182000/M
1
15
16
17
18
20
10
2
3
4
5
7
6
8
Materials and surface treatment of mountings and accessoriesStandard cylinders
X 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2Bearing: POMX 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2
X 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2.Bolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303)
G-X 6 Cr Ni 18 9 (1.4308; AISI 304)
—
—
X 10 Cr Ni S 18 9 (1.4305, AISI 303)—X 10 Cr Ni S 18 9 (1.4305; AISI 303).Bolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303).Eyebolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303).——
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
Air consumption (l/cm stroke) at 6 barOutstroke InstrokeOutstroke Instroke
Theoretical forces (N) at 6 bar
E
R
BH
L8 + #
GGL2
VD PL
EEL12
KW
AM
KK
ø B
e 1
1
L 9
BG
RT
ø B
A e
11
BG
RT
BH
A
B
VA
MM
h 9
WH
AP
A - B
EE
PL
KV SW
1 1
2
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
Typ Ø L8 L10 L11 at 0 mm at 25 mmLPDA/182032/MT 32 94 247 7LPDA/182040/MT 40 105 278 8LPDA/182050/MT 50 106 294 8LPDA/182063/MT 63 121 325 9LPDA/182080/MT 80 128 357 9LPDA/182100/MT 100 138 387 9LPDA/182125/MT 125 160 462 12
LPDA/182000/MT
Missing dimensions see page 6
Missing dimensions see page 6
# Stroke
#2
#1 Stroke for the first cylinder
Stroke for the second cylinder
at per
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.08
LPDA/182000, LPDA/182000/M
Front or rear stud A Piston rod swivel AK
BBD
D TG
TG
Rear flage B Front flage G Foot C
B 1
L 2
L
F
KK
4°4°
KK
3 2 4 1
UF
TF
FB
RE
MF
AOAUA
T AH
ø AB
TR
E
Stainless steel
(Corresponds to DIN ISO 6431, Style MX1)
(Corresponds to DIN ISO 6431 and VDMA 24562 Part 2, Style MS1)(Corresponds to DIN ISO 6431 and VDMA 24562 Part 2,Style MF1 and MF2)
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
Dimensions of mountings with different materials or surface treatment are the same, if not special information notes are given.
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
2 Piston rod seal 15 Cushion seal 26 ‘O’ ring 210 Piston seal 211 Wear ring 126 ‘O’-ring 1
Model Spares kit ComprisingDescription Quantity Piston rod
* Insert stroke length
Item
Dimensions of mountings with different materials or surface treatment are the same, if not special information notes are given.
4/04 N/UK 5.11.005.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
18D-LTPneumatic pressure switches
For extreme temperatures -40°C to +85°CRelative pressure - 1 to 16 bar
Technical dataMedium:Neutral, gaseous and liquid fluids, non-combustibleOperation:DiaphragmPort sizes:G1/4 (BSP), 1/4 NPT (on request), FlangeOperating pressure:-1 to 16 barElectrical connection:Acc. to DIN EN 17031-801 (DIN 43650 A) orAcc. to IEC 947-5-2 (M 12 x 1)Fluid temperature:Reproducibility: -25 to +85°CReliability: -40 to +80°CAmbient temperature:Reproducibility: -25 to + 85°CReliability: -40 to +80°CTemperature at switching element:+80°CConsult our Technical Service for use below +2°C.
Mounting:OptionalViscosity:Up to 1000 mm2/sRepeatability:±3%, for vacuum ± 4% of final valueSwitching element:Microswitch (gold plated contacts)Degree of protection:IP65 for conn. DIN 43650IP67 for conn. M 12 x 1
Switching function:Microswitch SPDTTerminals 1 - 3:Contacts close onrising pressure.Terminals 1 - 2:Contacts open onrising pressure.
Switching functionM12 x 1:Microswitch SPDTTerminals 1 - 4:Contacts close onrising pressure.Terminals 1 - 2:Contacts open onrising pressure.
2 3
1
p
2 4
1
p
4/04N/UK 5.11.005.02
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
18D-LT options with electrical connection DIN EN 17031-801 (DIN 43650 A)*
18D-LT options with electrical connection M 12 x 1 (Max. allowable voltage 30 V)*
** Reference pressure is atmospheric air pressure# Short-term pressure peaks are not allowed to exceed this limit value during operation.Operative utilization of the limit value is not permitted.The limit value corresponds to the maximumpressure## Typical values‡ Switching function reversed (Signal with rising vacuum).Key to materials: Al = AluminiumNBR = PerbunanVMQ = Silicon
Options selector
088˙˙5˙
Eletrical connection SubstituteDIN EN 175301-803 (DIN 43650, form A) 7M 12 x 1 8
Ordering informationTo order, quote part number from table overleaf, e.g. G 1/4 ported switch with a pressure range of 0,5 to 8 barquote: 00888800335577
Pressure difference (bar)##lower range upper range
Maximumover-pressure(bar)#
Switching cycles(1/min)
Pressure sensor material Fluid connection kg Drawing no.Housing Seal Type Size
* Plug not supplied
4/04N/UK 5.11.005.03
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
Accessories
0574767 (brass) 0574773 (brass) 0554737 0523058 (2 m cable) 0523056 (without cable) 0523057 (2 m cable) 0523055 (without cable)0550083 (stainless steel) 0553258 (stainless steel) 0523053 (5 m cable) 0523052 (5 m cable)
Pressure port reducingnipple
Snubber Connector M 12x190°4 pins
Connector M 12x1Straight4 pins
Cover (withadjustment screw)
Making and/or breaking capacityChange-over switch with gold-plated contacts
Reference number of switchings: 30/min, reference temperature: +30°C.Spark quenching with diode with d.c. and inductive load: Imax = 1,5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
Proposal for spark extinction with direct voltage1. Diode D parallel to the inductive load.Observe correct polarity with connection (positive pole atcathode).
Specificatons for erasing diode:Nominal voltage of the diode UD ∫ 1,4 x Us.Nominal current of the diode IN ∫ Iload.
Select fast switching diodes (blocking recovery time trr√ 200 [ms]).
2. RC element parallel to the load (or parallel to theswitching contact).Suitable for direct voltage and alternating voltage.
Ratings:R in [∆] Ÿ 0,2 x Rload in [∆]C in [µF] Ÿ Rload in [A]
+ (AC)
- (AC)
p
D R
C
R Last
I Last
V S
4/04N/UK 5.11.005.04
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
G 1/4 Flange
WarningThese products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, fornon-industrial applications, life-support systems, or other applicationsnot within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid powersystems can fail in various modes.
The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provide adequatesafeguards to prevent personal injury or damage to equipment in theevent of such failure.
System designers must provide a warning to end users in thesystem instructional manual if protection against a failure modecannot be adequately provided.
System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.
27
20
30
30
15
5,3 72
9,5
2
27
20
30
30
15
5,3 72
15,5
2
30
1,2
721
20
30
15
5,3 3
G 1/4 A
G 1/2 A
31
43
22
❑ 30 7
1,5
G 1/4 A
34
46
G 1/4
Ø21,5
22
2 1/4 NPT on request
M12
x 1
20
10
30
21,2
9,2
30
3 ‘O’ ring 5 x 1,5
2 1/4 NPT on request
Adjustable switch pointAfter releasing the locking screwClockwise rotation = encreasing switch pointAnti-clockwise rotation = decreasing the switch point
+-
4
5
5
4 Switch point screw
Locking screw
1
G 1/4
2
3
Pressure port reducing nippleMaterials: brassModel: 0574767Materials: stainless steel (1.4301)Model: 0550083
High corrosion and acid resistantmaterialsFrictionless operationNo maintenance or lubricationIdeal for short stroke, high-forceapplicationsHigh isolation level for vibratingmachinesVery easy to install – no alignmentproblems
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar max.Operating temperature:-40°C to +70°C for KM/31000(Standard)-25°C to +90°C for TKM/31000 (Butyl)-20°C to +115°C for EKM/31000(Epichlore)Consult our Technical Service for use below +2°C
Strokes:80 to 380 mm max., depending ondiameter and number of convolutions.
MaterialsEnd plates, fixing studs and centralring: stainless steel 1.4301Rubber part: fabric reinforced NR-,SBR- and BR compound rubber(KM/31000), fabric reinforced butyl(TKM/31000), fabric reinforcedEpichlore (EKM/31000)Important note: The design of these air bellows allows anoperation at an angle of 5° to 25°. The top and bottomplate can be out of alignment, depending on the height ofthe air bellow and the number of convolutions. To avoiddamage, mechanical stops at both end positions have tobe used. To return air bellows to their minimum height anexternal return force must be used. The thrust dependsdirectly on the height of the air bellow: when heightincreases, the thrust decreases. As the outside diametervaries in operation there must be enough clearancearound the air bellow.
Serviceable air bellowsStainless steelKM/31000Single actingØ 8 to 14Ë"
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: disregard option positions not used.
KM/31081 8 x 1 80 G1/2 KM/31082 8 x 2 175 G1/2 KM/31101 10 x 1 100 G1/2 KM/31102 10 x 2 225 G1/2 KM/31103 10 x 3 330 G1/2 KM/31121 12 x 1 100 G1/2 KM/31122 12 x 2 225 G1/2 KM/31123 12 x 3 330 G1/2 KM/31141 14Ë x 1 125 G1/2 KM/31142 14Ë x 2 265 G1/2 KM/31143 14Ë x 3 380 G1/2
Standard models
Safety note: These actuators must not be pressurised when unrestrained.For exact calculation for compact air bellows please contact our Technical Service.
KM/31000 Stainless steel – standard serviceable air bellows
Serviceable air bellowsStainless steel
KM/31000Single acting
Ø 8 to 14Ë"
B min. B max.(mm) (mm) Ø A Ø D Ø F Ø N kg
Installation heightModel
Actuators
www.norgren.com/info/en192192
Compact air bellowsPM/31000 Single actingØ 2È to 12"
Frictionless operationNo maintenance or lubricationIdeal for short stroke, high-force applicationsHigh vibration isolation levelEasy, compact installation
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar maximumOperating temperature:-40°C to + 70°C for PM/31000(Standard)-25°C to + 90°C for TPM/31000(Butyl)-20°C to + 115°C for EPM/31000(Epichlore)Consult our Technical Service for use below +2°C
Strokes:From 20 to 315 mm max.,depending on diameters andnumber of convolutions
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: Disregard option positions not used.Safety note: These actuators must not be pressurisedwhen unrestrained.For exact calculation for compact air bellows pleasecontact our Technical Service.
Port sizeModel Nominal Ø (inch)x convolutions
Maximum stroke(mm)
193
3
8
B m
in.
B m
ax.
XA A
ø 6,5
78
36
ø 95
M 6
G 1/4
B m
in. B m
ax.
XA A
G 3/8
93
ø 140
110
ø7
M6
15
6
�
°°°1
20°
B m
in.
B m
ax.
X X1
A A
G 1/2
127
153
ø 190
44,5
M8
ø 8,5
M8
1410
,5
17
°°°°
°°°4
5°
90°
PM/31041, PM/31042
PM/31061, PM/31062
Clearance around the air bellow
Section X
Section X
Section X1
Section X
Clearance around the air bellow
Clearance around the air bellow
Standard air bellowsPM/31021 to PM/31023
G 3/4
F
A
Z
D
A A
X
B m
in.
B m
ax.
ø N
M8
16
PM/31081, PM/31123
Clearance around the air bellow
PM/31061 6 x 1 55 55 110 0,97 PM/31062 6 x 2 115 80 195 1,30
kg
PM/31021 2 È x 1 20 50 70 0,21 PM/31022 2 È x 2 45 65 110 0,26 PM/31023 2 È x 3 65 80 145 0,30 PM/31041 4 Ë x 1 40 50 90 0,73 PM/31042 4 Ë x 2 80 65 145 0,91
PM/31081 8 x 1 95 55 150 PM/31082 8 x 2 185 80 265 PM/31091 9 Ê x 1 105 55 160 PM/31092 9 Ê x 2 230 80 310 PM/31121 12 x 1 105 60 165 PM/31122 12 x 2 215 85 300 PM/31123 12 x 3 315 120 435
Ø A Ø D Ø F Ø N Z kg225 135 70 240 Centric 1,80220 135 70 240 Centric 2,30 255 160 89 275 38 2,30255 160 89 275 38 3,10335 228 157,5 360 73 3,80325 228 157,5 350 73 5,20325 228 157,5 350 73 7,00
Compact air bellowsPM/31000
Single acting
Ø 2È to 12"
Model Nominal Ø(inch) xconvolutions
Strokes(mm)
InstallationheightB min. (mm)
InstallationheightB max. (mm)
kgModel Nominal Ø(inch) xconvolutions
Strokes(mm)
InstallationheightB min. (mm)
InstallationheightB max. (mm)
Model Nominal Ø(inch) xconvolutions
Strokes(mm)
Installation heightB min.(mm)
B max.(mm)
Actuators
www.norgren.com/info/en194194
Frictionless operationNo maintenance or lubricationIdeal for short stroke, high-force applicationsHigh vibration isolation levelSimple to install
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar maximumOperating temperature:-40°C to + 70°C for M/31000(Standard)-25°C to + 90°C for TM/31000(Butyl)-20°C to + 115°C for EM/31000(Epichlore)Consult our Technical Service for use below +2°C
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: Disregard option positions not used.
M/31061 6" x 1 55 G1/2M/31062 6" x 2 115 G1/2M/31081 8" x 1 80 G1/2M/31082 8" x 2 175 G1/2M/31101 10 x 1 100 G1/2M/31102 10 x 2 225 G1/2M/31103 10 x 3 330 G1/2M/31121 12 x 1 100 G1/2M/31122 12 x 2 225 G1/2M/31123 12 x 3 330 G1/2M/31141 14Ë x 1 125 G1/2M/31142 14Ë x 2 265 G1/2M/31143 14Ë x 3 380 G1/2M/31162 16 x 2 315 G1/2M/31163 16 x 3 430 G1/2M/31212 21 x 2 280 G3/4M/31262 26 x 2 410 G3/4
Standard models
Safety note: These actuators must not be pressurised whenunrestrained.For exact calculation for compact air bellows please contact ourTechnical Service.
Reversible seal allows 3/2 or 5/2 wayfunctionExhaust air recirculationCrossover-free switching, switch-overfunction guaranteed even with smallcross section air supplySafety function in the evennt of powerfailure provided by mechanical returnspring (monostable design)Add-on manual overrideSuitable for outdoor installation ifequipped with corresponding solenoidValves suitable for hazardouusenvironments in combination with Exapproved solenoids (ATEX, FM) Minimal electrical power consuumption –therefore many safety ratings possible,e.g. EEx ia
Technical dataMedium:Compressed air, filtered, lubricated andnon-lubricated, instrument air, nitrogenor other neutral, dry fluids Flow direction:Fixed Mounting position:Optional Operating pressure:2 to 8 bar with internal air supply Temperature range:Valve: -40°C to +65°CSolenoid: see solenoid tableFor temperatures below 0°C use conditioned dry air. Ifinstalled outdoors protect all connections against thepenetration of moisture
MaterialsHousing: aluminium black anodized,brass, stainless steel 1.4305Seal: NBR (Perbunan)
# NAMUR interface DIN 3845/Nov. 98, port P and auxiliary supply in flange surfacexxxx Insert solenoid codes from table below. ***** Insert voltage codes from table below
Power consumption Protection class Temperature °C Electrical Solenoid24 V d.c. 230 V a.c. Fluid Ambient connection code
Requires connector plug type 0570275 for d.c., connector plug with rectifier type 0663303 for a.c. or a.c./d.c. For connector plugs and accessories see page 384
97105 SeriesIndirect solenoid actuated spool valvesFor single and double acting actuators with NAMUR interface3/2, 5/2, 5/3, GÊ, Ê NPT
Solenoid actuators (ATEX) for intrinsically safe circuitCat. II 1G EEx ia IIC T5/T6*, Cat. II 2D T 90°C
When selecting an intrinsically safe power supply, the permissible maximum values according to the EC-Type Examinationcertificate KEMA 03 ATEX 1051X must be taken into account. The low effective inductivity and capacity can be ignored.*Fluid and ambient temperature: -40 to +80°C (T5), -40 to +70°C (T6)
Min, RequiredNominal required voltage at Temperatureresistance switching Resistance terminal °C SolenoidRRV coil current RW 65 coil RW 65 Fluid Ambience code
Solenoid actuators with FM approvalIntrinsically safe: IS/I, II, III/1/ABCDEFG/T6 Ta = 65 °C; I/0 AEx ia IIC/T6 Ta = 65 °C - 0588672/B; EntityNonincendive: NI/I/2/ABCD/T6 Ta = 65 °C; S/II,III/2/FG/T6 Ta = 65 °C; NEMA Type 4
When selecting an intrinsically safe power supply, the permissible maximum values according to the FM approvalshould be taken into account. The low effective inductivity and capacity can be ignored.
200 ∆ 33 mA 240 ∆ 8 V 2050391 ∆ 24 mA 470 ∆ 11 V 2051736 ∆ 17 mA 880 ∆ 15 V 20521220 ∆ 13 mA 1460 ∆ 19 V 2053
124 ∆ 43 mA 150 ∆ 6,4 V -40 ... +65 +65 2040159 ∆ 38 mA 193 ∆ 7,3 V -40 ... +65 +65 2041198 ∆ 34 mA 240 ∆ 8,2 V -40 ... +65 +65 2042248 ∆ 30 mA 301 ∆ 9,0 V -40 ... +65 +65 2043306 ∆ 27 mA 371 ∆ 10,0 V -40 ... +65 +65 2044378 ∆ 25 mA 458 ∆ 11,5 V -40 ... +65 +65 2045467 ∆ 23 mA 566 ∆ 13,0 V -40 ... +65 +65 2046566 ∆ 21 mA 686 ∆ 14,4 V -40 ... +65 +65 2047692 ∆ 19 mA 839 ∆ 15,9 V -40 ... +65 +65 2048
21312
12 10
Port size1/3 (5) 2 (4)
kg ModelFlow (l/min)Function Actuation Materials
24 V d.c. 0240024 V a.c. 02450110 V a.c. 11050230 V a.c. 23050
Voltage codesCodeVoltage
1,6 W IP 00 (without connector) +80 -15 ... +50 02531,9 W IP 00 (without connector) +50 -15 ... +50 07633,2 W Cat II 2 G EEx m II T5 +70 +70 0298
3,5 VA Cat II 2 G EEx m II T5 +70 +70 02990,7 W Cat II 2 GD EEx me II T5/T6 -40 ... +80/70 4200
1,3 VA Cat II 2 GD EEx me II T5/T6 -40 ... +80/70 42010,7 W Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 1/2 NPT 46000,7 W Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 M20x1,5 4602
1,3 VA Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 1/2 NPT 46011,3 VA Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 M20x1,5 46031,4 W NEMA 4, 4X, 6, 6P, 7, 9; wire 460 mm -20 ... +60 -20 ... +60 3720
For single and double acting actuators with NAMUR interface
3/2, 5/2, 5/3, GÊ, Ê NPT
3.3
13.821.8
110.8
4.3
3.5
92.8
335.1
51.5
3245
4
101
36.6
47.1
57.6
59.1
27.5
315
4.8
13.827
.5
33 22 22
43
134
4.3
3.5
116
43
67
3245
4.35
105.
5
3 1 5
27.5
4.3
162.2
4.8
13.827
.5
46
61.5
83.5
105.5
204
71.5
95.5
32
3.4
3.5
4510
5.5
3 1 5
27,5
4,3
180
4,8
13,827
,5
46
79
101
123
222
89,3
113,3
32
3,4
3,5
4510
5,5
3/2 NAMUR DIN 3845/Nov. 98 5/2 Single solenoid model 5/2 Double solenoid model
5/3 Double solenoid model
EEx m
4133
82,5
89
19,5
63,5
73
IP 00, 0253
40,5
38
15,5
55
74
18
29,5
*
Pg 11
27,5
12
EEx me
54,5
107
64,5
91,5
42M 20 x 1,5
27
ø 13
40,5
Solenoids
NEMA
40,5
63
84
33,5
43
26
2
1/2 - 14 NPT
*
IP 00, 0763
40,5
49
17
56
53,5
27
89
3443
Pg 11 12
*
27,5
EEx ia
6066
80
63Pg 13,5
33
Ø16*
�
119
416
62
FM
6066
97,5
63
1/2-14 NPT
33
Ø16*
119
416
62
* Connector rotates 4 x 90°
* Connector rotates 4 x 90°
* Ø 13 (with spacer tube)
* Ø 13 (with spacer tube)
* Stranded wire AWG 18 (~460 mm length)
Valves
www.norgren.com/info/en332332
Reversible seal allows 3/2 or 5/2way functionExhaust air recirculationCrossover-free switching, sswitch-over function guaranteed evenwith small cross section airsupplySafety function in the evennt ofpower failure provided bymechanical return spring(monostable design)Suitable for outdoor insstallation ifequipped with correspondingsolenoid
Technical dataMedium:Compressed air, filtered, lubricatedand non-lubricated, instrument air,nitrogen or other neutral, dry fluids Flow direction:Fixed Mounting position:Optional Operating pressure:2 to 8 bar with internal air supply Temperature range:Valve: -40°C to +65°CSolenoid: see solenoid tableFor temperatures below 0°C use conditioned dry air. Ifinstalled outdoors protect all connections against thepenetration of moisture
MaterialsHousing: aluminium black anodized,brass, stainless steel 1.4305Seal: NBR (Perbunan)
97105 Series (50 mW/5 mW)Indirect solenoid actuated spool valvesFor single and double acting actuators with NAMUR interface3/2, 5/2, 5/3, GÊ, Ê NPT
# NAMUR interface DIN 3845/Nov. 98, port P and auxiliary supply in flange surfacexxxx Insert solenoid code from table below yyy Insert electrical connection code from table below
Rated Voltage at Rated Rated Resistance Max. values EEx i Type of Ambient Solenoidpower terminal current current coil Ui Ii Pi protection* temperature codePN UN Ion Ioff RN5 mW ∫ 5 V ∫ 1 mA √ 0,1 mA 5100 ∆ 28 V 120 mA 0,75 W EEx ia IIC T4 -40 ... +80°C 2080
25,2 V 155 mA 0,75 W EEx ia IIC T6 -40 ... +45°C22 V 224 mA 0,75 W
50 mW ∫ 10 V ∫ 2,7 mA √ 1,3 mA 3700 ∆ 28 V 120 mA 0,75 W II 2G EEx ia IIC T4 -40 ... +65°C 208125,2 V 155 mA 0,75 W II 2G EEx ia IIC T6 -40 ... +45°C22 V 224 mA 0,75 W
21312
12 10
Solenoid operating details
Connector CodeM12 x 1,5 003Round connector 004M16 x 1,5 005
Electrical connections
Port size1/3 (5) 2 (4)
kg ModelFlow (l/min)Function Actuation
333
97105 Series (50 mW/5 mW)Indirect solenoid actuated spool valves
For single and double acting actuators with NAMUR interface
3/2, 5/2, 5/3, GÊ, Ê NPT
3
30
101
45
32
51,5
35,1
24
94109
59,8
82,6
47
3
14
28
22004
003
002
001
3
2
41
5
24
27
13
17,5
4.8
13,8
27,5
67
89,5
3322
22
4,35
11713
2
101
45
43 4324 1
32
Pg11
Pg9
3
12
4
5
2522
22
101
163
45
3524
4,35
32
30
9
1,2
35
89,6
67
4,8
13,8
27,5
3
12
4
5
004
003
002
001
Pg11
2517
,822
22
101
180,
8
45
3524
4,35
32
30
9
1.2
35
89,6
67
4,8
13,8
27,5
24
27
13
17,5
Pg11
Pg9
120,
8
3/2 NAMUR DIN 3845/Nov. 98 5/2 Single solenoid model
5/2 Double solenoid model
5/3 Double solenoid model
Fluid controlsolutionsNorgren is a leading global supplier of Fluid control
solutions with proven products widely accepted by
manufacturers and users worldwide.
The winning combination of Norgren, Herion and
Buschjost expertise and technology brings you all the
benefits of many years of specialized experience and
understanding of the process industry applications.
Norgren is committed to providing added value
through machine and process improvement and this is
further backed by our commitment to provide an
unequalled service which is customized to meet the
specific needs of our individual customers.
At the heart of this service is the capability to design
and engineer added-value, integrated solutions to
answer the most demanding applications challenges.
A new Fluid Control catalogue will be available soon.You can visit www.norgren.com for more information onthese products.
• Control flow of air, water, oil and otherfluids and gases
• 2/2 and 3/2 valves
~ Diaphragm and piston seat type
~ Pressure range up to 40 bar (specials upto 70 bar); medium temperature -196°Cup to +200°C
~ Can be operated by solenoid, by air-driven actuator and by motor drive
~ In-line and Namur versions
~ Threaded connections 1/4 to 3 inches(BSP or NPT) and flanged connections1/2 to 6 inches (DIN or ANSI)
• TÜV approval, including risk analysis forpetrochemical plants
• Ex-approvals worldwide
Solenoids, with ATEX approval inprotection classes: EEx m II T4, EEx me II T3/4, EEx de II C T4/5, EEx md,Eex na, Eexia. NI, IS, XP
Approvals
24011/24010 solenoid valves, Namur andInline with TÜV Approval IEC 61508
97105 Series indirect solenoid valves,Namur and Inline for -40°C
Pressure actuated angle seat valves
Click-on® piston valves
Motorised valves
Dust filter valves pressure actuated
Click-on® diaphragm valve
Twist-on® Dust filter valves solenoidactuated
Valves
www.norgren.com/info/en356356
VP10 SeriesProportional pressure control valveGÊ
Robust proportional I/P and E/P convertersSuitable for a wide range of applicationsHigh accuracyHigh flow versions availableIP 65 protection in normal operation
Technical dataMedium:Compressed air filtered to 5 µm, oil-free, dryOutput signal:0,2 to 1,0 bar, 0,2 to 2,0 bar, 0,2 to 4,0 bar (2 wireversion), 0,14 to 6 bar, 0,14 to 8 bar (3 wireversion) Flow:Up to 300 l/min Air consumption:<4 bar: 0,85 l/min typical at 50% signal>4 bar: 1,75 l/min typical at 50% signalOperating pressure:At least 0,7 bar above maximum required outputpressure range Ambient temperature:-40°C to +85°C Consult our Technical Service for use below +2°C.
Mounting:Integral surface mounting bracket provided forpreferred vertical mounting. 50 mm pipe mountingkit available Response time:<2 bar: less than 0,5 seconds (dependent on input for 10 to 90% step change andoutlet pressures)>2 bar: 2 seconds for 10 to 90% step change Total error:±0,5% of span (typical, independent error includesthe combined effect of non-linearity, hysteresis,deadzone and repeatability) Temperature effect:Average 0,1% of span/°C for span and zero overoperating range Supply sensitivity:< 0,075% span output change per % supplypressure change Failure mode:Signal falls to bleed pressure when electrical supplyfails Weight:0,825 kg
20 D SeriesFor low-pressure pneumatics0 to 1,6 bar
High accuracyMicroswitch with gold-plated contacts(silver plated for field mounting)Electrical coonnection:Connector acc. to DIN 43650 orscrewed cable gland
Technical dataMedium:Neutral gases and liquids (water,hydraulic oil, lubricants, light gas oil)Mounting position:OptionalOperating pressure:0 to 16 barAmbient temperature:0 °C to +60 °C-40 °C to +80 °C (weather-proof*)* On requestConsult our Technical Service for use below +2°C.
Viscosity:Max. 1000 mm2/sFluid temperature:0 °C to +80 °CTemperature at switchingelement:+80 °C max.Seal rate:> 10-7 mbar•I•s-1Repeatability:±1% of final value (referred topressure control)Vibration immunity:max. 5 Hz/4 g (sinosoidal)To be avoidedSwitching cycles:max. 10/minuteDegree of protection:IP65
MaterialsHousing: aluminium die cast,aluminium die cast, tin plated (field)Sensor: steel 1.0333, St. st.1.4305/1.4301, brassSealing: Plastic diaphragm (Perbunan)or Viton (FKM)
Fixed switching pressure differences
Adjustable switching pressure differences
Variant codes (YY)
00 Steel/1.0333 / NBR DIN 43650* G1/4 female –05 Steel/1.0333 / NBR M20 x 1,5 G1/4 female –
NPTF port sizes on request* Connector not within scope of supply. If required please order separately, part no. 0570110** Special pressure ranges on request*** Typical values
1
2 3
p
Pressurerange (bar)**
Over pressure(bar)
Switching pressure difference (bar)*** Drawing no.Range start Range end
Model
Pressurerange (bar)**
Code Materials Electrical connection Fluid port size Options
Over pressure(bar)
Switching pressure difference (bar)***Range start Range end Max.
L/R Ÿ 10 msReference number of switchings: 30/min, reference temperature: +30°CSpark quenching with diode with d.c. and inductive load: Imax = 1.5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# 50% of the respective switching current I nearly doubles contact life. The mechanical life depends on the field of application.‡ Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
View H
21,2��
30� �
9,2��
D��
2232,5
M 2
0 x
1,5
6 ø 6,5 - 8,8
Electrical connectionDIN 43650
Electrical connectionM20 x 1,5
G 1/4
ø 132
~ 15
0
A��
ø 64
G 1/4
~ 46
A��
AccessoriesPlease see page 392 for details of plugs, brackets, surgedampers and adaptors.
1 2
Pressure switches
www.norgren.com/info/en390390
High accuracyGold-plated contactsWith Ex-Versions acc. to ATEX 100aWeatherproof (silver-platedcoontacts)Power supply connections:DIN 43650 plug or screwed cablegland
Technical dataMedium:For neutral and aggressive gasesand liquidsMounting position:Optional, preferably with pressureconnection underneath Ambient temperature:-25°C to +80°C-40°C to +80°C (weatherproof) Consult our Technical Service for use below +2°C.
Viscosity:Up to 1000 mm2/s (±450 ssu). Fluid temperature:-10°C to +100°C Temperature at switchingelement:+80°C Seal rate:>10-7 mbar·l·s-1 Repeatability:±1% from range end value(depending on pressure regulation) Degree of protection:IP 65
MaterialsBrass, stainless steel: see table
AlternativemodelsFor power plants, part no. 18XXX12with Harting connector type HAN 7Dincluding 47 K ∆ wire breakingmonitoring, G1/2 male stainlesssteel, Pg16Ex-Versions acc. to ATEX 100a onrequest
20 D Series (Allfluid)For pneumatics, aggressive gases and liquids-1 to 100 bar
Adjustable switching pressure differences
YY = replace with code from table below
Variant codes (YY)
# Plug not included. If required, order model 0570110, see page 384
* Not for pressure sensor variants 00 and 05 ** Only for pressure sensor variants 10 and 15*** Typical values
Switching pressure difference (bar)***Code 00, 10, 20Range start Range end
Switching pressure difference (bar)***Code 21Range start Range end
Switching pressure difference (bar)***Code 05, 15, 25Range start Range end
Model
391
20 D Series (Allfluid)For pneumatics, aggressive gases and liquids
-1 to 100 bar
43,8��
46,8��
104��
Ansicht H��
M4 x 10 tief�
�
5,8��
43,5��
22��
C��
C��
D��
D��
A��
A��
50,7
��
22� �
81� �
70� �
5� �
19��
1,8��
19��
115,5��
H��
Standard housingFor electrical and pneumatic connectors see below
Load level Type of Type of load Umin Maximum permanent current Imax [A] at U [V] Contact life #current [V] 30 48 60 125 250 electrical mechanical
at Imax at I Ÿ 0
Reference number of switchings: 30/min, reference temperature: +30°CSpark quenching with diode with d.c. and inductive load: Imax = 1.5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# 50% of the respective switching current I nearly doubles contact life. The mechanical life depends on the field of application.‡ Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
View H
Standard * a.c. Resistive load 12 5 5 5 5 5 5 x 104 >107
G 1/4 male - G 1/2 maleStainless steel 1.4305 (AISI 303/304 S)Type 0550083
G 1/4 male - G 3/8 femaleSteelType 0574764
G 1/4 male - 1/4 NPT femaleBrassType 0574765
22,5
43,5
G1/4-14 NPT
SW 27
43,5
1/2 NPT
G1/4
12
22,5
G1/4
12
13
36
Ø21,5
G1/4
30 6,512
Ø20
Reducing nipple for pressure connection
393
Robust sensor for hydraulic applicationsTemperature compensated3-wire technology (0 to 10 V)2-wirre technology (4 to 20 mA)Excellent long-term stabilityStainless steel measuring element-not oil-fiilled
Technical dataMedium:For neutral and aggressive gases or fluidsFluid connection:G1/4 male with nipple manometer connectionMounting position:OptionalPressure range:0 to 800 barFluid temperature:-20°C to +85°C(-40°C to +120°C versions available on request)Ambient temperature:-20°C to +85°C(-40°C to +120°C versions available on request)Consult our Technical Service for use below +2°C.
Degree of protection:IP 65 (acc. to DIN 40050)Shock protection:30g, xyz, to DIN EN 60068-2-27Vibration protection:3g, 5 to 500 Hz, xyz, DIN EN 60068-2-6Electrical connection:M12 x 1/cable (on request)Supply voltage:UB = 12 to 30 V d.c. (current output)UB = 15 to 30 V d.c. (voltage output)max. 10% residual ripple within UBOutput signal:4 to 20 mA (Two-wire technology)0 to 10 V (Three-wire technology)Varying frequency output on requestElectromagnetic compatibility:Interference immunity acc. to EN 50081. Part 1Interference immunity acc. to EN 50082. Part 2Load resistance:See diagramPolarity:Short-circuit proofMeasuring range:See table belowLinearity:< ±0,5% final value
18 S Allfluid SeriesAllfluid/hydraulic applications with relative pressureAllfluid pressure sensor analog, 0 to 800 bar
P
I
P
U
Output signal
Standard versions (electrical connection M 12 x 1)*
Protect compressed air systems fromover-pressurisationSimple, low cost ‘Pop’ type units fordirectt connection to pressure vesselsand associated componentsPre-set and tamper resistant reliefvalvess protected from ingress
Technical dataMedium:Compressed air onlyAmbient temperature:-40°C to +230°C (1002)-20°C ... +80°C (61B2)-4°C ... +40°C (V05)Consult our Technical Service for use below +2°C
AlternativemodelsPre-set relief pressure (1002, 61B2,V05)Pull ring (1002)Plastic models (V05)Consult our Technical Service for use below +2°C
V 0 5 - 2 0 0 - P ˙ ˙ ˙
NPT (brass) ABSPT (brass) BPush in connection (plastic) P
1002 V05 (brass) V05 (plastic)
Nominal setting Substitute1,00 bar (15 psi) 151,35 bar (20 psi) 201,70 bar (25 psi) 252,00 bar (30 psi) 302,35 bar (35 psi) 352,70 bar (40 psi) 403,00 bar (45 psi) 453,35 bar (50 psi) 503,70 bar (55 psi) 554,00 bar (60 psi) 60
To order a 1002 unit with pull ring fitted substitute ‘8’ for ‘0’ at the last digit, e.g. 1002/BG008.
Ported pressure relief valves - Pop type1002, 61B2, V05R1/4
Additional pressure settings are available up to 15,5 bar(225 psi), please contact Norgren Technical Service fordetails
Available as Cat 1 under P.E.D.as standard
Cat 4 available on request
Norgren pressure relief valves comply with categoryO(S.E.P.) and category 1 of the Pressure EquipmentDirective 97/23/EC. If categories 2, 3 or 4 products arerequired contact our Technical Services.
473
5
6
7
4
8
9
10
3
2
1
2 4 6 8 10 12 14 16 18 20 dm3/s
bar
V05-200-135A
V05-200-P45P
Ported pressure relief valves - Pop type1002, 61B2, V05
11-818* compact, high precisionregulators for air gauging, laboratoryuse and precise pilot controll11400/20AL-X for high accuracy withconstant bleed, recommended aspilot control for R18/11-808/R244regulators and 40AC relief valvesR38 instrument regulators for processand petro-chemical industriiesSee also page 416 for R24 specialpurpose regulators * Not recommended for dead end use, consult ourTechnical Service for details
Technical dataMedium:Compressed air onlyMaximum inlet pressure: 25 bar (11400/20AL-X)10 bar (11-818-100)14 bar (11-818-110)8 bar (11-818-999)20 bar (R38/B38)Gauge ports:G1/8 (11400/20AL-X)1/4" NPTF (R38/B38)Ambient temperature:-20°C to +80°C -40°C to +80°C (R38/B38)0°C to +70°C (11-818)Consult our Technical Service for use below +2°C
* For panel mounting substitute 3 at the last digit e.g 11400-2G/PC103# For 5µm element substitute 1 at the 8th digit e.g. B38-200-B1CA** Typical mid-range variance from set pressure with 7 bar inlet at 2 dm3/s (10 bar inlet for 20AL-X2G).A Norgren oil removal filter should be fitted upstream of these units, see pages 434 and 460Can be adjusted to zero bar outlet pressure and generally to pressure in excess of those specified
11400/20AL-X11-818
R38
###
** *
B38
Port size Service kitModelkgRange (bar) *Accuracy (bar)** Operation2787-962787-982787-9711400-100/20AL11400-100/20AL11400-100/20AL11400-100/20ALR38-100RR38-101RR38-101RB38-100AB38-100AB38-100A
* Typical flow with 7 bar inlet pressure, 6,3 bar set pressure and a droop of 1 bar
Can be adjusted to zero outlet pressure, and, generally, to pressures in excess of those specified.* Typical flow with 7 bar inlet pressure, 1 bar set pressure and a droop of 0,05 bar.
** Typical flow with 12 bar inlet pressure, 8 bar set pressure and a droop of 1 bar.
Drain kits:# Manual drain 2787-43‡ Auto drain 3000-87
* Outlet pressure can be adjusted to pressures in excessof, and less than, those specified. Do not use these units tocontrol pressures outside of the specified ranges.# 1/4" only. ‡ 1/2" only
Thread SubstitutePTF AISO RC Taper BISO G Parallel DDiaphragm Substitute
Relieving with panel nut 4Non relieving with panel nut 5
Drain SubstituteAutomatic AManual – short bowl BManual – long bowl M
R38 and B38 Lloyds Register TypeApprovedMaterials meet NACE*recommendations (MR-0175, 2002revisiion)Suitable for marine, offshore, foodprocessing and dental applicationsR38/B38 models for precissionregulation and high flow rates* National Association of Corrosion Engineers –recognised oil-field recommendation for resistance tosulphide stress cracking common in well-head and othercorrosive environments
Technical dataMedium:Compressed air onlyMaximum inlet pressure: 17 bar (autodrain)31 bar (R38, B38 manual drain)Gauge ports:1/4 PTF (R38, B38)Ambient temperature:-40°C to +80°C (R38, B38)Consult our Technical Service for use below +2°C