Top Banner
LP & HP6 BOP 0 to 1-1/2 0 to 1-1/2 0 to 3/8 1-1/4 1-1/2 1-1/2 1-1/2 2-3/8 EU MxF 2-7/8 EU MxF 2-3/8 EU MxF 2-3/8 EU MxF 2-7/8 EU MxF 3-1/2 LP MxF 2-7/8 EU MxF H 2 S Standard Standard Standard Standard Standard H 2 S 1,500 1,500 3,000 3,000 3,000 3,000 3,000 01-08700 01-02400 01-04200 01-04700 01-06300 01-06775 01-09605 Rod/Wireline Size (in.) Vertical Bore (in.) Thread (in.) Service Working Pressure (PSI) Model Number Popular Blow Out Preventers * 1.90 2.44 1.90 1.90 2.44 2.44 2.44 *Double E has numerous Blowout Preventer models available. Contact a Double E representative for your specific requirements. If we don’t have a Blowout Preventer model for your application, we can develop one for you. LP & HP6 Blow Out Preventers O-ring Screw Housing Cap 1 5 2 3 4 LP BOP Key Features Closes on 0 to 1-1/2 inch rod sizes. Easily upgraded to HP6 for higher working pressure. Convenient handles require no tools to operate. Contact Double E for other options and configurations. HP6 Rams close on 0 to 3/8 inch diameter wirelines or rods. Easy to maintain in the field. Convenient handles require no tools to operate. Contact Double E for other options and configurations. BOP Type LP LP HP6 HP6 HP6 HP6 HP6 HP6 Ram 46 46 48 48 48 48 48 Weight (lbs.)
2

LP & HP6 Blow Out Preventers - Double E, Inc. · LP Ram LP-DF Ram 2 2 2 1.90/2.44 1.90/2.44 1.90/2.44 Standard Standard Standard H2S Standard Standard Standard H2S Standard Standard

Oct 18, 2018

Download

Documents

phamnga
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LP & HP6 Blow Out Preventers - Double E, Inc. · LP Ram LP-DF Ram 2 2 2 1.90/2.44 1.90/2.44 1.90/2.44 Standard Standard Standard H2S Standard Standard Standard H2S Standard Standard

LP & HP6 BOP

0 to 1-1/20 to 1-1/20 to 3/81-1/41-1/21-1/21-1/2

2-3/8 EU MxF2-7/8 EU MxF2-3/8 EU MxF2-3/8 EU MxF2-7/8 EU MxF3-1/2 LP MxF2-7/8 EU MxF

H2SStandardStandardStandardStandardStandard

H2S

1,5001,5003,0003,0003,0003,0003,000

01-0870001-0240001-0420001-0470001-0630001-0677501-09605

Rod/WirelineSize (in.)

Vertical Bore(in.) Thread (in.) Service

WorkingPressure (PSI)

ModelNumber

Popular Blow Out Preventers*

1.902.441.901.902.442.442.44

*Double E has numerous Blowout Preventer models available. Contact a Double E representative for your specific requirements. If we don’t have a Blowout Preventer model for your application, we can develop one for you.

LP & HP6 Blow Out Preventers

O-ringScrew

Housing

Cap

1

5

2

3 4

LP

BOP Key Features

• Closes on 0 to 1-1/2 inch rodsizes.

• Easily upgraded to HP6 for higher working pressure.

• Convenient handles require no tools to operate.

• Contact Double E for other options and configurations.

HP6

• Rams close on 0 to 3/8 inch diameter wirelines or rods.

• Easy to maintain in the field.

• Convenient handles require no tools to operate.

• Contact Double E for other options and configurations.

BOP Type

LPLPHP6HP6HP6HP6HP6

HP6 Ram

46464848484848

Weight(lbs.)

Page 2: LP & HP6 Blow Out Preventers - Double E, Inc. · LP Ram LP-DF Ram 2 2 2 1.90/2.44 1.90/2.44 1.90/2.44 Standard Standard Standard H2S Standard Standard Standard H2S Standard Standard

double Ea Parco company

Replacement Parts for Popular LP & HP6 BOP Models

***If you don’t see the material you need listed, contact a Double E representative. We offer eleven elastomers for sealing applications.

CapO-ring Screw RamPlate Screw O-rings CapHousing

**Contact one of our knowledgeable Double E representatives to identify the correct housing for your application.

This brochure is intended as a guideline and reference. Appropriate testing and validation by users having technical expertise is necessary for proper use of Double E products.!

24 3

1

35 6 4

NitrileHNBRAflas®

Viton®

30 to 200°F-30 to 300°F40 to 400°F-15 to 450°F

Rubber MaterialTemperature Range

Key Rubber Properties

Double E, Inc., 1261 Profit Drive, Dallas, Texas 75247214-631-2290 Fax 214-630-4712 www.doubleeinc.comForm 1014 3/16 ©2016 Double E, Inc.

Housing**

Cap

Screw

O-ring

1

2

2

2

-

1.90/2.44

1.90/2.44

1.90/2.44

-Standard

H2SStandard

H2S--

-01-1905001-1925001-2030001-2030001-2530001-20791

DescriptionItem Qty. Vertical Bore (in.) Service Part Number

LP & HP6 BOP Main Components

1

2

3

4

-----

NitrileHNBR

Rubber Material***

5 HP6 Ram

Viton® is a registered trademark of DuPont.AFLAS® is a registered trademark of Asahi Glass.

HP6 Ram

LP Ram

LP-DF Ram

2

2

2

1.90/2.44

1.90/2.44

1.90/2.44

StandardStandardStandard

H2SStandardStandardStandard

H2SStandardStandard

H2SHigh Temp, H2S

NitrileNitrileNitrileHNBRNitrileNitrileNitrileHNBRNitrileNitrileHNBRViton

DescriptionItem Qty.Vertical Bore

(in.) ServiceRubberMaterial***

LP & HP6 BOP Rams

5

6

7

01-2655501-2960001-2760001-2990001-2555001-2600001-2610001-2888001-2630001-2530001-2840001-28902

Part Number0 - 3/81-1/41-1/21-1/23/41-1/81-1/41-1/41-1/2---

Rod/WirelineSize (in.)

HP6

LP

LP

BOPType

6 LP Ram 7 LP-DF Ram