Top Banner
24 December 2013 PMI Revision 00 1 LP BY PASS SYSTEM  
43

LP ByPass System

Apr 13, 2018

Download

Documents

Ashwani Dogra
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 1/43

24 December 2013 PMI Revision 00  1

LP BY PASSSYSTEM 

Page 2: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 2/43

24 December 2013 PMI Revision 00  2

Presentation outline• Introduction of LP Bypass system

• Overview of LP Bypass

•  System details and lay out

• Control scheme of LP bypass system•  

Page 3: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 3/43

24 December 2013 PMI Revision 00  3

L P BYPASS SYSTEM

• LP bypass bypasses steam to IPT & LPT & maintain flow

through RH.

Function of LP bypass:-

1. To monitor the pressure in reheat system and to control it

under certain operating condition.

2. The volume of steam not utilized by the IPT & LPT during

start up & shut down must pass through condenser.

Page 4: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 4/43

24 December 2013 PMI Revision 00  4

LP Bypass system provide a very effective means ofcontrolling reheat  – steam flow during

Startup Low-load / part load operation

Sudden load rejection

LP BYPASS SYSTEM

Page 5: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 5/43

24 December 2013 PMI Revision 00  5

It enhances fast starting capability of turbines from allinitial conditions e.g. 

Cold condition

Warm condition

Hot Condition

LP BYPASS SYSTEM

Page 6: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 6/43

24 December 2013 6

LP steam-bypass system operates in parallel with theturbine

Protects Condenser from excessive temperature andpressure that could result from sudden injection of

superheated steam

LP BYPASS SYSTEM

Page 7: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 7/43

24 December 2013 PMI Revision 00  7

• The controls for LP Bypass system are combination of electricaland well proven hydraulic system

• Electro-hydraulic converter provides the necessary linkbetween hydraulic actuator and electrical system

LP BYPASS SYSTEM

Page 8: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 8/43

24 December 2013 PMI Revision 00  8

SEQUENCE OF EVENTS RESULTING FROM LOAD

REJECTIONUpon receiving load rejection signal from electricalsystem:

Turbine Speed Controller assumes control ofthe TG set

It initiates fast closure of HP & IP turbinecontrol valves through position controller

Fast closure of turbine control valves cause animmediate decrease in HP 1st. Stage pressure

Page 9: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 9/43

24 December 2013 PMI Revision 00  9

SEQUENCE OF EVENTS RESULTING FROM LOAD

REJECTION Pressure increases in main and reheat steam

systems

These pressure changes are sensed by HP and LPBypass controllers

Respective bypass valves are opened

Page 10: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 10/43

24 December 2013 PMI Revision 00  10

• If LP steam- bypass system fails or the

condenser cannot accept LP bypass

steam , Safety Valves open and dump

steam to atmosphere

Page 11: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 11/43

24 December 2013 PMI Revision 00  11

Page 12: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 12/43

24 December 2013 PMI Revision 00  12

Page 13: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 13/43

24 December 2013 PMI Revision 00  13

Page 14: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 14/43

24 December 2013 PMI Revision 00  14

System details and layout

• The controls for LP Bypass system are combinationof electrical and well proven hydraulic system

Electro-hydraulic converter provides the necessarylink between hydraulic actuator and electricalsystem

Page 15: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 15/43

24 December 2013 PMI Revision 00  15

Control scheme

• Set point formation

• Pressure control for LP bypass system

LP bypass HYDRAULIC System• Protection system

Page 16: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 16/43

24 December 2013 PMI Revision 00  16

• The LPBypass Controller acts as a maximumpressure Controller

• It regulates the reheater pressure either to thefixed set value or suitably derived variable setvalue

• If the reheater pressure exceeds this set value,the Controller causes the electro-hydraulic

converter to operate and initiate bypassoperation

Control scheme

Page 17: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 17/43

24 December 2013 PMI Revision 00  17

Set Value formation

The Two set values  –  fixed and variable are formed for theLPBypass control system

set value to be used is determined by a maximum valueselector

For the formation of variable set point, a pressuretransducer is used to measure the steam pressure in HPturbine

Page 18: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 18/43

24 December 2013 PMI Revision 00  18

Bypass Controller Block Diagram

Page 19: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 19/43

24 December 2013 PMI Revision 00  19

LP Bypass System

Page 20: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 20/43

24 December 2013 PMI Revision 00  20

Features of LPBP Controller

• LPBP controller maintains pressure after reheater

by controlling LP bypass valves

• It acts on the coil of the LPBP E-H converter to

position the control valves.

• Two setpoints, fixed and variable are used in

maximum selection circuit

• Variable setpoint is derived from HP first stage

pressure

• Water spray is in two stages depending on steam

flow through LPBP stations.

• LPBP valves cannot open until adequate spray

water pressure and required vacuum is there and

condenser wall temp is not high.

• Valves can also be operated manually

Page 21: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 21/43

24 December 2013 PMI Revision 00  21

LP BYPASS SETPOINTS

Page 22: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 22/43

24 December 2013 PMI Revision 00  22

CONTROLLER

OUTPUT

CHARACTERI

STICS 

Page 23: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 23/43

24 December 2013 PMI Revision 00  23

Hydraulic Mode of Operation 

• The controller controls plunger coil of ElectroHydraulic Converter

• With increase in voltage, the jet pipe is deflected

towards right• Converter piston moves downwards leading to

generation of LPB signal oil through Follow-uppistons provided in the hydraulic control system

Page 24: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 24/43

24 December 2013 PMI Revision 00  24

Hydraulic Mode of Operation 

• Two Follow-up Pistons actuate and open first stage ofwater injection valve

• Remaining two Follow-up Pistons generate signal oil foropening LPBypass stop and control valve 

Page 25: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 25/43

24 December 2013 PMI Revision 00  25

DJUSTMENT

OF

LPBYP SS

CONVERTER

Page 26: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 26/43

24 December 2013 PMI Revision 00  26

Design of LPBypass Valves for 210 MW

Steam Turbine

• Controlled by8 bar mineraloil

Page 27: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 27/43

24 December 2013 PMI Revision 00  27

Design of LPBypass Valve for 500

MW Steam Turbine

• Controlled by 36bar FRF

Page 28: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 28/43

24 December 2013 PMI Revision 00  28

Protection Devices

Low Vacuum Condensor Protection

Spray Water Pressure Switch

Condensor Temperature Protection

Page 29: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 29/43

24 December 2013 PMI Revision 00  29

Protection Devices cause closure of

bypass station in case of following

eventualities

a) Condensor vacuum is low ( > 0.6 bar absolute )

b) Spray water pressure is low (< 8.5 / 9.5 bar )c) Temperature of condenser body is high (> 90° C )

Page 30: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 30/43

24 December 2013 PMI Revision 00  30

Water Injection Valves operate in two stages

• Second stage Water Injection Valves openwhen steam flow through LPBypass Valvesincreases more than 45 %

CURVE FOR LPBYPASS

Page 31: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 31/43

24 December 2013 PMI Revision 00  31

CURVE FOR LPBYPASS

CONTROLLER

Page 32: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 32/43

24 December 2013 PMI Revision 00  32

Damping device

Page 33: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 33/43

24 December 2013 PMI Revision 00  33

Page 34: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 34/43

24 December 2013 PMI Revision 00  34

Page 35: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 35/43

24 December 2013 PMI Revision 00  35

Actuator Bypass

Stop Valve

Page 36: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 36/43

24 December 2013 PMI Revision 00  36

ActuatorLPBPCV

500 MW

Page 37: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 37/43

24 December 2013 PMI Revision 00  37

Pilot valve

for Water

Injection Valve

Page 38: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 38/43

24 December 2013 PMI Revision 00  38

Water

InjectionValve

Page 39: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 39/43

24 December 2013 PMI Revision 00  39

Combined Bypass

Stop & Control

Valve 210 MW

Feedback for Pilot valve of

Page 40: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 40/43

24 December 2013 PMI Revision 00  40

Feedback for Pilot valve ofBypass Control Valve 210 MW

Page 41: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 41/43

24 December 2013 PMI Revision 00  41

Page 42: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 42/43

24 December 2013 PMI Revision 00  42

Page 43: LP ByPass System

7/27/2019 LP ByPass System

http://slidepdf.com/reader/full/lp-bypass-system 43/43

THANK YOU