Top Banner
November 9, 2017 Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 Presentation to The Passaic River Community Advisory Group
20

Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Mar 07, 2018

Download

Documents

vokiet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

November 9, 2017

Lower 8.3 Miles of the Lower Passaic River Operable Unit 2

Presentation to The Passaic River Community Advisory Group

Page 2: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Agenda

•Sediment sampling schedule and objectives

•Sample collection metrics

•Sediment sampling locations and progress

•Sampling vessels in use

Page 3: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment Sampling Schedule and Objectives

Page 4: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment Sampling Timeline

Activity

• Pre-mobilization activities

• Mobilization and Site Set-up

• Sediment Sampling

• Laboratory Analyses

Timeframe

• Early August to Early October

• Early to mid-October

• Mid-October to early January 2018

• Late October to late January

Page 5: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment Core Collection and Data Analysis

Sediment cores collected to provide input to dredging and engineered capping design, dredged material handling, dewatering, transportation & disposal planning

•Chemical analysis

•Geotechnical characterization

•Waste characterization

Page 6: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sample Collection Metrics through November 8, 2017

Page 7: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment core locations planned: 958

Sediment core locations completed: 341 or 36%

Sediment cores collected: 341 for sediment chemistry98 for waste characterization26 for geotechnical data5 DRET/CST

Page 8: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Samples sent to the laboratory: 3,385

Sediment sample analysis types: 3,056 for chemistry235 for waste characterization94 for geotechnical data

Sediment cores collected with Sonic Rig: 30 locations

Sediment cores collected with Vibracore: 146 locations

Sediment cores collected manually: 165 locations

Page 9: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment Sampling Locations and Progress

Page 10: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core
Page 11: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sediment Sampling Vessels in Use

Page 12: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

The three pontoon boats used for sample collection

Page 13: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Pontoon boats moored at the river access barges

Page 14: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Vibracore Sampling

Vessel awaiting use for sampling

Page 15: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Pontoon boat departing from base barge

Page 16: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Pontoon boat departing from base bargeBarge mounted sonic drill rig

Barge mounted sonic drill rig

Page 17: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Vibracore SamplingBarges used for river access and egress at the Clean Earth property

Page 18: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sonic Drill Rig Courtesy of Ann Arbor Technical Services (ATS)Access ramp at the Clean Earth property

Page 19: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Core logging at 80-120 Lister Avenue

Page 20: Lower 8.3 Miles of the Lower Passaic River Operable Unit 2 ...passaic.sharepointspace.com/Public Documents/Passaic CAG... · Operable Unit 2 Presentation to The ... Sediment Core

Sample processing and prep for lab at 80-120 Lister Avenue