  • MAKING MODERN LIVING POSSIBLE

    Technical Information

    Loop Flushing Valve

    powersolutions.danfoss.com

    http://powersolutions.danfoss.com

  • Revision history Table of revisions

    Date Changed Rev

    Dec 2014 Danfoss Layout EA

    Oct 2011 Backpage updated AB

    Mar 2007 Update backpage AA

    July 2003 First edition -

    Technical Information Loop Flushing Valve

    2 520L0641 • Rev EA • Dec 2014

  • General informationApplication..........................................................................................................................................................................................4Description..........................................................................................................................................................................................4Specifications.....................................................................................................................................................................................5Model code......................................................................................................................................................................................... 5Performance....................................................................................................................................................................................... 5Mounting.............................................................................................................................................................................................6

    Service InformationAdjustment procedure................................................................................................................................................................... 8Service information..........................................................................................................................................................................8

    Technical Information Loop Flushing Valve

    Contents

    520L0641 • Rev EA • Dec 2014 3

  • Application

    The loop flushing valve, applied in a hydrostatic transmission circuit, maintains high quality of theworking fluid in the transmission power loop. While many transmissions can operate satisfactorilywithout a loop flushing valve, the addition of loop flushing improves fluid quality and generally extendstransmission life.

    Consider the loop flushing valve when any of these exist:• Sustained operation at low pressure and high speed• Operation where continuous pressure exceeds 1000 hours per year• Cylinders in the hydrostatic circuit• Flow restricting valves in the power loop• Frequent operation of high pressure relief valves• Long power loop lines• Extraordinary life requirements

    Danfoss recommends monitoring fluid quality under field operating conditions for extended periods oftime to determine loop flushing requirements. For a complete discussion of loop flushing and fluidquality, refer to Danfoss bulletins BLN-9886 Transmission Circuit Recommendations and 520L0463Hydraulic Fluids and Lubricants, Technical Information.

    Description

    The high pressure ports (1 and 2) of the valve are externally connected to the work or system auxiliaryports of the main hydrostatic transmission circuit. The valve drain port (4) must be externally connectedto the case drain return line of the transmission — preferably at the motor so that fluid flushes throughthe motor case and returns to the reservoir.

    The shuttle valve exposes the low pressure side of the circuit to the charge relief valve. When properly set(see Adjustment procedure on page 8) the charge relief valve flushes a desired quantity of working fluidfrom the transmission power loop. The charge pump replaces this fluid.

    You may specify a drain orifice to limit maximum flushing flow in circuits where the low side pressure ishigh or varies over a large range.

    Schematic diagram

    X

    X

    X

    Orifice(optional)

    Drain port 4

    System press. gauge port 6

    System port2

    Charge press.

    gauge port 3

    System port1

    System press. gauge port 5

    P104 162E

    Technical Information Loop Flushing Valve

    General information

    4 520L0641 • Rev EA • Dec 2014

  • Specifications

    System pressure

    Maximum high side 480 bar [6961 psi]

    Maximum low side 70 bar [1015 psi]

    Charge relief setting

    Minimum 15 bar [218 psi]

    Maximum 28 bar [406 psi]

    Nominal charge relief settings are ±1.4 bar [±20 psi] and are set at a flow of 3.8 ±0.9 l/min [1 ±0.25 US gal/min] at 49º C [120º F]

    Model code

    8800485- -

    Charge pressure 15 to 28 bar, 1 bar increments Example: 20 = 20 bar [290 psi]

    Orif ce00 = None 09 = Ø 2.40 mm [0.0945 in.] 12 = Ø 3.19 mm [0.1255 in.]

    i

    Performance

    Valve without orifice

    0

    100

    200

    300

    400

    500

    600

    6543210

    FlowP104 185E

    Maximum setting

    Adjustment range

    Minimum setting

    Low

    sys

    tem

    pre

    ssu

    re (a

    bov

    e d

    rain

    ) (bar)(psi)

    (US gal/min)

    10

    20

    30

    40

    5

    15

    25

    35

    0 2 4 6 8 10 12 14 16 18 20 22(l/min)

    Technical Information Loop Flushing Valve

    General information

    520L0641 • Rev EA • Dec 2014 5

  • Valve with 2.40 mm [0.0945 in.] orifice

    0

    1000

    6543210

    Flow

    750

    500

    250

    Maximum setting

    Minimum setting

    Adjustment range

    Low

    sys

    tem

    pre

    ssu

    re (a

    bov

    e d

    rain

    ) (bar)(psi)

    (US gal/min)

    10

    20

    30

    40

    50

    60

    70

    0 2 4 6 8 10 12 14 16 18 20 22(l/min) P104 186E

    Mounting

    Installation drawing

    Adjustable chargerelief valve1-1/16 in hex (locknut)1/2 in hex (adjustment)

    9/16 in-18 SAE str. thd.O-ring boss system pressuregauge port 5

    9/16 in-18 SAE str. thd.O-ring bossdrain port 4

    9/16 in-18 SAE str. thd.O-ring bosssystem pressuregauge port 6

    P104 163E

    60.5[2.38]

    95.0[3.74]

    21.3[0.84]

    14.0[0.55]

    87.6[3.45]

    78.2[3.08]

    36.8[1.45]

    36 max[1.417]

    8.6[0.34]

    15.9[0.625]

    typical

    80.8[3.18]

    73.7[2.90]

    15.2[0.60]

    31.8[1.25]

    Ø 10.7[0.42]

    Mounting holes

    60.7[2.39]

    13.0[0.51]

    9/16 in-18 SAE str. thd.O-ring bosscharge pressuregauge port 3

    9/16 in-18 SAE str. thd.O-ring bosssystem port 1

    9/16 in-18 SAE str. thd.O-ring bosssystem port 2

    Third-angleprojectionmm [in]

    Mount the loop flushing valve on any convenient flat surface that provides adequate support around thetwo mounting holes. Ensure the surfaces under the mounting bolts form a flat plane.

    Failure to provide a flat mounting surface could create valve housing distortion when the mounting boltsare torqued. Housing distortion may bind internal components and reduce the drive and/or brakingcapacity of the system.

    Technical Information Loop Flushing Valve

    General information

    6 520L0641 • Rev EA • Dec 2014

  • W WarningThe loss of hydrostatic drive line power in any mode of operation may cause a loss of hydrostatic brakingcapacity. A braking system, redundant to the hydrostatic transmission, must be provided which isadequate to stop and hold the system should such a condition develop.

    Technical Information Loop Flushing Valve

    General information

    520L0641 • Rev EA • Dec 2014 7

  • Adjustment procedure

    For initial setting of the valve package:

    1. Plumb an in-line flow meter into the drain line.

    If a flow meter is not available, use a clean container with a known volume and a stop watch tomeasure flow rate.

    2. Set the brakes or otherwise restrict machine motion.3. Stroke the transmission pump to build at least 34 bar [500 psi] differential system pressure.4. Adjust the relief valve in the flushing valve package to obtain the desired drain flow. Typically 7.5 to

    11.4 l/min [2 to 3 US gal/min] is sufficient. Rotating the adjusting screw counter-clockwise increasesflow and decreases the effective pressure setting by approximately 5 bar [73 psi] per turn.

    5. Torque the locknut 42 to 55 N•m [31 to 41 lbf•ft].6. Verify that pump charge pressure is above recommended minimum.7. Remove the flow meter from the circuit.

    Adjustment diagram

    Relief valve adjustmenth1/2 in

    Drain9/16 in - 18 str. thd.O-ring boss port

    P104 165E

    Locknuth1-1/16 int42 to 55 N•m [31 to 41 lbf•ft]

    Service information

    Component installation torque

    Description Wrench size Torque

    Gauge port plugs 9/16 in hex 27 to 47 N•m [20 to 35 lbf•ft]

    Charge relief lock nut 1 1/16 in hex 42 to 55 N•m [31 to 41 lbf•ft]

    Orifice plug 3/16 in internal hex 22 to 27 N•m [16 to 20 lbf•ft]

    Shuttle spool plugs 11/16 in 36 to 44 N•m [27 to 33 lbf•ft]

    Hose/tube fittings — 27 to 47 N•m [20 to 35 lbf•ft]

    Technical Information Loop Flushing Valve

    Service Information

    8 520L0641 • Rev EA • Dec 2014

  • Exploded view

    11

    16

    16A

    13

    16

    16A

    15

    3

    3

    12

    3A

    3A

    9

    44A

    2

    2A

    Enlarged bold type itemnumbers are recomended

    parts to be stocked for servicing

    2

    2A

    2

    2A

    15

    1

    t42 to 55 N•m [31 to 41 lbf•ft]h1-1/16 in

    t27 to 47 N•m [20 to 35 lbf•ft] h 9/16 in

    E101 098E

    t 36 to 44 N•m [27 to 33 lbf•ft]h11/16 in

    d

    I 3/16 int 22 to 47 N•m [20 to 35 lbf•ft]

    id

    dd

    d

    d

    dd

    t27 to 47 N•m [20 to 35 lbf•ft]h 9/16 in

    t27 to 47 N•m [20 to 35 lbf•ft]h 9/16 in

    t27 to 47 N•m [20 to 35 lbf•ft]h 9/16 in

    Technical Information Loop Flushing Valve

    Service Information

    520L0641 • Rev EA • Dec 2014 9

  • Replacement parts

    Item Part Number Description Quantity

    1 8800538 Housing assembly 1

    2 9005100-5600 Plug 3

    2A 9004201-3700 O-ring 3

    3 9005100-5600 Plug 2

    3A 9004201-3700 O-ring 2

    4 9005100-5600 Plug 1

    4A 9004201-3700 O-ring 1

    9 8510012 Charge relief valve kit 1

    11 9004201-6200 O-ring 1

    12 8800242-0009 Orifice plug – Ø 2.40 mm [0.0945 in] 1 (opt.)

    12 8800242-0011 Orifice plug – Ø 3.19 mm [0.1255 in] 1 (opt.)

    13 8800550 Shuttle spool 1

    15 513596 Spring guide assembly 2

    16 518016 Special plug 2

    16A 9004201-3700 O-ring 2

    Technical Information Loop Flushing Valve

    Service Information

    10 520L0641 • Rev EA • Dec 2014

  • Technical Information Loop Flushing Valve

    520L0641 • Rev EA • Dec 2014 11

  • Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic andelectronic components. We specialize in providing state-of-the-art technology and solutionsthat excel in the harsh operating conditions of the mobile off-highway market. Building onour extensive applications expertise, we work closely with our customers to ensureexceptional performance for a broad range of off-highway vehicles.

    We help OEMs around the world speed up system development, reduce costs and bringvehicles to market faster.

    Danfoss – Your Strongest Partner in Mobile Hydraulics.

    Go to www.powersolutions.danfoss.com for further product information.

    Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide supportfor our customers, ensuring the best possible solutions for outstanding performance. Andwith an extensive network of Global Service Partners, we also provide comprehensive globalservice for all of our components.

    Please contact the Danfoss Power Solution representative nearest you.

    Local address:

    Danfoss Power Solutions GmbH & Co. OHGKrokamp 35D-24539 Neumünster, GermanyPhone: +49 4321 871 0

    Danfoss Power Solutions ApSNordborgvej 81DK-6430 Nordborg, DenmarkPhone: +45 7488 2222

    Danfoss Power Solutions (US) Company2800 East 13th StreetAmes, IA 50010, USAPhone: +1 515 239 6000

    Danfoss Power Solutions(Shanghai) Co., Ltd.Building #22, No. 1000 Jin Hai RdJin Qiao, Pudong New DistrictShanghai, China 201206Phone: +86 21 3418 5200

    Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies toproducts already on order provided that such alterations can be made without changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

    520L0641 • Rev EA • Dec 2014 www.danfoss.com © Danfoss A/S, 2014

    Products we offer:

    • Bent Axis Motors• Closed Circuit Axial Piston

    Pumps and Motors• Displays• Electrohydraulic Power

    Steering• Electrohydraulics• Hydraulic Power Steering• Integrated Systems• Joysticks and Control

    Handles• Microcontrollers and

    Software• Open Circuit Axial Piston

    Pumps• Orbital Motors• PLUS+1® GUIDE• Proportional Valves• Sensors• Steering• Transit Mixer Drives

    Comatrolwww.comatrol.com

    Schwarzmüller-Inverterwww.schwarzmueller-inverter.com

    Turolla www.turollaocg.com

    Valmovawww.valmova.com

    Hydro-Gearwww.hydro-gear.com

    Daikin-Sauer-Danfosswww.daikin-sauer-danfoss.com

    ContentsGeneral informationApplicationDescriptionSpecificationsModel codePerformanceMounting

    Service InformationAdjustment procedureService information