P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]Unit 24b 176 South Creek Road Cromer NSW 2099 Page -1- MERITON APARTMENTS DA Application for: LOFTUS RESIDENTIAL DEVELOPMENT To be built at: 5 Loftus Street, Arncliffe __________________________________________________ BASIX Assessment Date of Issue: 11 th September 2009 This report has been prepared by Efficient Living Pty Ltd on behalf of our client Meriton Apartments. Efficient Living prepares all reports in accordance with the ASBA code of practice and is backed by professional indemnity insurance. This report takes into account our client’s instructions and preferred building inclusions.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]
This report has been prepared by Efficient Living Pty Ltd on behalf of our client Meriton Apartments. Efficient Living prepares all reports in accordance with the ASBA code of practice and is backed by professional indemnity insurance. This report takes into account our client’s instructions and preferred building inclusions.
P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]
Page -2-
PREPARED FOR :
PREPARED BY :
Meriton Apartments Level 11/528 Kent Street North Sydney NSW 2000 Contact : Phone : (02) 9287 2888 Fax : (02) 9287 2768
P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]
Page -3-
INTRODUCTION Efficient Living has investigated the estimated thermal comfort, water and energy usage of the proposed development to be built at 5 Loftus Street, Arncliffe. Heating and cooling loads for the development have been determined using NatHERS thermal simulation software. The report is based on the architectural drawings provided by Meriton and Design Imagery. For further details, refer to the individual BASIX certificates and ABSA reports respectively. ANALYSIS The BASIX assessment is divided into three sections, each independently measuring the efficiency of the development. These are Water, Thermal Comfort and Energy. BASIX requires a minimum target of 40% for the Water section. A NatHERS pass or fail is required for the thermal comfort section and a minimum required target of 20% for the energy section. WATER The proposed development has achieved the BASIX Water target of 40%. The water usage of the development is calculated based on the number and efficiency of permanent fixtures and appliances such as: taps, showerheads and toilets, the dish washer and clothes washing machine. The size of the rain tank and number of connections has a huge impact on your water score as does the area of gardens and lawns and weather or not low-water plant species are incorporated. THERMAL COMFORT Thermal Comfort targets are set by the department of planning in the form of heating and cooling caps. The buildings thermal physics is measured using NatHERS thermal performance assessment tools. This equates an expected level of energy consumption to heat and cool each dwelling per annum expressed in MJ (mega joules) per square meter of floor area. Each unit has individual heating and cooling caps and a weighted average heating and cooling load for the whole development. The weighted average caps are a lot harder to achieve than the individual unit caps. Bonus points can be obtained for the cooling loads through natural cross ventilation. ENERGY The proposed development has achieved the energy target of 20% to pass this section. The energy usage of the development is calculated based on the efficiency of fixed appliances that will be used. This includes the air conditioning system, hot water system, lighting, exhaust fans and the cook top, oven, and clothes drying facilities.
P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]
Page-4-
BASIX Inclusions – Loftus Residential Development All units in buildings A, B, C & D have reached the targets as set for new dwellings in NSW. The inclusions as outlined in the table below have been incorporated in each unit to allow them to reach their environmental sustainability targets.
Building B – 451, 550, 650, 551, 651, 555, 655, 556, 656
Building C – G11, 111, 211, 311, 411, 511, 401, 501, G07, 207, 403, 404, 503
& 504
Building D – 124, 224, 324, 424, 125, 225, 325, 425
All remaining units do not require external wall insulation
Floor: Concrete - no insulation
Thermal Comfort
Upgrades
0.5m wide sunhoods required over all ‘eat in’ sun bays in buildings A & D
Units: Building A: A144, A344 & A544
Window reductions: All glazing in bathrooms and kitchens is 1900H internally
even if full height on the front façade.
The following windows are to be a maximum of 1900H internally:
Units C412 & C512 – both bedroom windows
Units C401 & C501 – Bed 2 and study windows
Landscaped areas Total area of garden and lawn: 1,485 m2
Indigenous / Low water Garden: 0m2
Tapware All units and communal areas to have 3 star showers & 4 star tapware & toilets
Rain tank volume 20,000L rain tank capacity
Harvested roof areas Main roof areas from all buildings are to be plumbed into the rain tank
Rain tank connections All communal area gardens & 5 car washing bay
Hot water units 1 central gas fired boiler, with R0.6 (25mm) insulation to all piping.
P. 02 9971 0003 | F. 02 9971 0003 | M. 0400 083 525 | E. [email protected]
Page-5-
Heating and Cooling All units to have individual single phase reverse cycle air conditioning:
Living & bedrooms – 5 star (zoned)
Ventilation with-in
dwellings
Kitchen range hood to be recirculating with a manual on / off switch
All bathrooms to have externally ducted exhaust with a manual on / off switch
The laundry must have externally ducted exhaust with a manual on / timer off
Lighting Florescent lighting provided throughout both buildings communal areas and
with-in the units. All light fittings to be dedicated.
Appliances
Gas cook top and electric oven
Well vented fridge spaces
Clothes dryers with 2.0 star energy efficiency
Dish washers with 3.0 star water efficiency and 3.0 star energy efficiency
Unit owners / tenants responsible for their own clothes washing machines
Common area Ventilation All car parks to have supply and exhaust air with carbon monoxide monitors
and 2 speed fans.
Gym & Office to have air-conditioning operated with a time clock.
The pool area to have supply and exhaust air operated with a time clock.
The garbage rooms to have exhaust fans running constantly.
Plant, switch and pump rooms to have exhaust fans interlocked to lights.
Unit entries and hallways to have ventilation supply operated with a time clock.
Common area lighting
All car park area lighting to have zoned switching and motion sensors.
All lift lighting systems are to be connected to a call switch button.
Entry lobbies and hallways to have zoned switching.
Lighting to all other areas to have manual on / off switches.
Lift motor All lifts to have gearless traction with VVVF motor.
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Assessor Certificate Multiple Dwellings
Certificate Version 6.1. Prior versions not valid after 1 March 2006 Issued in accordance with
BASIX Thermal Comfort Simulation Method.
Assessor Name: Tracey Cools Company: Efficient Living ABSA #: 20101 Address: 24B, 176 South Creek Road, Cromer Phone: 9971 0003 Fax: 9971 0003 Email: [email protected] Declaration of interest: NoneClient Name: Tom Hutchison Company: Meriton Apartments Pty Ltd Address: Level 11, 528 Kent Street Sydney 2000 Phone: 9287 2888 Fax: 9287 2777 Email: [email protected] Project Address: 5 Loftus Street, ARNCLIFFE NSW 2205 LOT / DP: 101 / 706950 Applicant: Meriton Apartments Pty Ltd LGA: Rockdale City Council Assessment Date: 09/09/09 File ref: - Software: NatHERS Version: 2.32B Documentation All details, upon which this assessment has been based, are included in the project documentation that has been stamped and signed by the Assessor issuing this certificate, as identified below:Thermal Performance Spec: Cover sheet Drawings: parking 1, 1A, 2, G/1,2,3,4,5,6,7,8, roof, site, elevations - Issued 09/09/09
Affix assessor stamp
Building Specifications: Only specifications, detailed on Drawings identified above, have been referencedABSA Assessor Certificate Assessor # 20101 Certificate # 73231102 Issued: 11/09/09
Thermal performance specifications Page 1 of 3Floor area (M2) Predict. loads (MJ/M2/y)
Unit number(s) Certificate number Cond. Uncond. Heat Cool
(Sens & Lat)Concessions
Qualify for ventilation
bonus
A132 73231102 86 0 81 44 No No
A133 60547255 107 0 102 55 No No
A134 77479166 84 0 96 65 No No
A135 55222864 53 0 95 71 No No
A136 41515543 65 0 131 64 No No
A137 30658472 65 0 37 46 No No
A138 24455819 90 0 92 16 No No
A139 93262244 74 0 115 31 No No
A140 47016382 106 0 77 22 No No
A141 90426544 68 0 65 56 No No
A142 47196076 79 0 81 19 No No
A143 44674962 79 0 81 19 No No
A144 59858371 109 0 95 94 Yes Yes
73231102
11/09/09
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Thermal Performance SpecificationsThese are the Specifications upon which the Certified Assessment is based. If details included in these Specifications vary from other drawings or written specifications, these Specifications shall take precedence. If only one specification option is detailed for a building element, that specification must apply to all instances of that element for the project. If alternate specifications are detailed for a building element, the location and extent of alternate specifications must be detailed below and / or clearly indicated on referenced documents Windows Product ID Glass Frame U value SHGC Area M2 Detail
Supplier not specified Single Light grey low-E Aluminium 4.6 0.360 Varying To units listed on the upgrade table
Supplier not specified Single Light grey tint Aluminium 6.6 0.529 Varying To the remainder of the complex
Skylights Product ID Glass Frame U value SHGC Area M2 DetailNone Window and skylight U and SHGC values, if specified, are according to ANAC 2005. Alternate products or specifications may be used if their U value is lower, and the SHGC value is less than 10% higher or lower, than the U and SHGC values of the product specified above.External walls Construction Insulation Colour – solar abs. DetailPrecast concrete Foil (Sisalation) Not specified To units listed on the upgrade table Precast concrete None Not specified To the remainder of the complex Internal walls Construction Insulation DetailPlasterboard on studs None With-in each unit Hebel None To inter-tenancy walls Floors Construction Insulation Covering DetailConcrete slab None Tiles to wet areas & entry Carpet to Living rooms & bedrooms Ceilings Construction Insulation Detail Plasterboard R2.0 To top floor units & where exposed balcony is above Plasterboard None Where neighbouring units are above Roof Construction Insulation Colour – solar abs. DetailConcrete slab roof Foil (Sisalation) Light -SA <0.475 Top floor units & where exposed balcony is above Window cover Internal (curtains) External (awnings, shutters, etc) Not specified None
Varying eaves widths and offsets, as per plans Overshadowing from units above Overshadowing Overshadowing structures Overshadowing trees Adjacent Buildings No
Orientation, Exposure, Ventilation and InfiltrationOrientation of nominal north: Varying as per plan ABSA Assessor stamp Terrain category: Suburban Roof ventilation: Unventilated Cross ventilation: Standard Subfloor: Above carparks & neighbouring units Living area open to entry: No Doors separate living areas: No Stair open to heated areas: Varying Seals to windows and doors: Yes Exhaust fans without dampers: No Ventilated skylights: No Open fire, unflued gas heat: No Vented downlights: No Wall and ceiling vents: No
73231102
11/09/09
Certificate number: 237202M_02
This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated29/06/2006 published by the Department of Planning. This document is available atwww.basix.nsw.gov.au
This certificate is a revision of certificate number 237202M lodged with the consentauthority or certifier on 12 March 2009 with application 307/2009.
It is the responsibility of the applicant to verify with the consent authority that theoriginal, or any revised certificate, complies with the requirements of Schedule 1Clause 2A, 4A or 6A of the Environmental Planning and Assessment Regulation2000
Director-GeneralDate of issue: Friday, 11 September 2009
NSW GOVERNMENTDepartment of Planning
Score
✓ Water: 41 (Target 40)
✓ Thermal comfort: pass (Target pass)
✓ Energy: 20 (Target 20)
Project addressProject name Loftus Residential Development - Bui_02
Street address 5 Loftus Street Street Arncliffe 2205
Local Government Area Rockdale City Council
Plan type and plan number deposited 706950
Lot no. 101
Section no. -
Project typeNo. of unit buildings 1
No. of units in unit buildings 92
No. of attached dwelling houses 0
No. of separate dwelling houses 0
Site detailsSite area (m²) 16319
Roof area (m²) 1590
Non-residential floor area (m²) 0
Residential car spaces 89
Non-residential car spaces 13
Common area landscapeCommon area lawn (m²) 440
Common area garden (m²) 443
Area of indigenous or low water usespecies (m²)
0
Assessor detailsAssessor number 20101
Certificate number 73231102
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 1/22
Description of project
The tables below describe the dwellings and common areas within the project
Unit building - Building A, 92 dwellings, 7 storeys above ground
(b) Common areas and central systems/facilities(i) Water(ii) Energy
2. Commitments for attached dwelling houses
3. Commitments for separate dwelling houses
4. Commitments for common areas and central systems/facilities for the development (non-building specific)(i) Water(ii) Energy
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 5/22
Schedule of BASIX commitments
The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.
1. Commitments for unit building - Building A
(a) Dwellings
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).
✓ ✓
(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it. ✓ ✓
(d) The applicant must install an on-demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "Hot water recirculation" column of the table below. ✓ ✓
(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below. ✓ ✓
(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both). ✓(g) The pool or spa must be located as specified in the table. ✓ ✓(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling in
the table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.
✓ ✓ ✓
Fixtures Appliances Individual pool Individual spa
Dwellingno.
Allshower-heads
All toiletflushingsystems
Allkitchentaps
Allbathroomtaps
HWrecirculationor diversion
Allclotheswashers
All dish-washers
Volume(maxvolume)
Poolcover
Poollocation
Poolshaded
Volume(maxvolume)
Spacover
Spashaded
Alldwellings
3 star 4 star 4 star 4 star no 2 star 3 star - - - - - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 6/22
Alternative water source
Dwelling no. Alternative watersupply systems
Size Configuration Landscapeconnection
Toiletconnection(s)
Laundryconnection
Pooltop-up
Spa top-up
None - - - no no no no no
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.
✓ ✓ ✓
(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table. ✓ ✓
(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system system is specified in the table for "Living areas" or "Bedroom areas", then no systems may beinstalled in any such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide forday/night zoning between living areas and bedrooms.
✓ ✓
(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.
✓ ✓
(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.
✓ ✓ ✓
(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:
(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and ✓
(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump. ✓
(h) The applicant must install in the dwelling:
(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below; ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 7/22
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and ✓ ✓
(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table. ✓(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "well
ventilated". ✓
Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system
Dwellingno.
Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control
Individual pool Individual spa Appliances & other efficiency measures
Dwellingno.
Pool heatingsystem
Timer Spa heatingsystem
Timer Kitchencooktop/oven
Refrigerator Wellventilatedfridgespace
Dishwasher Clotheswasher
Clothesdryer
Indoor orshelteredclothesdrying line
Privateoutdoor orunshelteredclothesdrying line
Alldwellings
- - - - gas cooktop &electric oven
- yes 3 star - 2 star yes no
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 13/22
(iii) Thermal Comfort Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.
(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.
(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.
(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.
(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.
(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.
✓ ✓
(g) Commitment (h) below, applies to the rooms or areas of a dwelling which are listed in the "Cross Ventilation" table below ascomprising a breeze path for the dwelling.
(h) The applicant must construct the dwelling so that at least one ventilation opening is provided in each such room or area. (If onlyone room or area of a dwelling is mentioned for a breeze path, then that room or area must have at least two ventilationopenings).
✓ ✓
(i) The two ventilation openings referred to in (h), must meet the following specifications:
(aa) be located as specified for the breeze path in the table;
(bb) not be more than 15 metres apart;
(cc) if the dwelling is below the 10th storey of the building, be at least 1 square metre in size, or if the dwelling is on or abovethe 10th storey, be at least 0.5 square metres in size and be located above door head level in the room; and
(dd) have only 1 doorway, or opening less than 2 square metres in size, located in the direct path between them.
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
A135 95 71 71.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 14/22
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
A136 131 64 64.0
A141 65 56 56.0
A535 132 68 68.0
A544 106 90 54.0
A637 49 44 44.0
A638 108 16 16.0
A639 131 31 31.0
A641 75 62 62.0
A732 97 42 42.0
A733 117 54 54.0
A734 113 59 59.0
A735 99 36 36.0
A736 92 38 38.0
A737 105 71 71.0
A738 106 40 40.0
A739 118 61 61.0
A144, A344 95 94 56.4
A545, A548 110 24 24.0
A546, A547, A549 129 25 25.0
A145, A148, A345,A348
96 25 25.0
A235, A335, A435,A635
83 37 37.0
A241, A341, A441,A541
63 64 64.0
A137, A237, A337,A437, A537
37 46 46.0
A138, A238, A338,A438, A538
92 16 16.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 15/22
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
A339 within main living areaVentilation openings: >3 m apart andon adjacent external walls
- - -
A144, A344,A544
main living to Bedroom1Ventilation openings: opposite externalwalls
main living to Bedroom2Ventilation openings: opposite externalwalls
within main living areaVentilation openings: >3 m apart andon adjacent external walls
-
A139, A239,A439, A539,A639
- - - -
All otherdwellings
- - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 16/22
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 17/22
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Lift car (No. 1) - - compact fluorescent connected to lift call button No
Lift car (No. 2) - - compact fluorescent connected to lift call button No
Central energy systems Type Specification
Lift (No. 1) gearless traction with V V VF motor
Number of levels (including basement): 8
Lift (No. 2) gearless traction with V V VF motor
Number of levels (including basement): 8
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 18/22
4. Commitments for common areas and central systems/facilities for the development (non-building specific)
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
Central systems Size Configuration Connection (to allow for...)
Central water tank -rainwater or stormwater (No.1)
5000 To collect run-off from at least:- 1590 square metres of roof area of buildings in the
development- 0 square metres of impervious area in the development- 0 square metres of garden/lawn area in the development- 0 square metres of planter box area in the development(excluding, in each case, any area which drains to, orsupplies, any other alternative water supply system).
- irrigation of 883 square metres of common landscapedarea on the site- car washing in 1 car washing bays on the site
Pool (No. 1) Volume: 60 kLs Location: Indoor pool & spa area (25%of total) -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 19/22
Central systems Size Configuration Connection (to allow for...)
Fire sprinkler system (No. 1) - So that fire sprinkler test water is contained within the firesprinkler system for re-use, rather than disposed.
-
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Indoor pool & spa area(25%of total)
ventilation (supply +exhaust)
time clock or BMS controlled compact fluorescent manual on / manual off No
Gym (25% of total area) air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Car park area (percentageof total area)
ventilation (supply +exhaust)
carbon monoxide monitor +2-speed fan
fluorescent zoned switching with motionsensor
No
Switch / Plant / Serviceareas (25% of)
ventilation exhaust only interlocked to light fluorescent manual on / manual off No
Garbage room (25% of totalarea)
ventilation exhaust only - fluorescent manual on / manual off No
Hallway & lobby's ventilation supply only time clock or BMS controlled compact fluorescent zoned switching No
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 20/22
Central energy systems Type Specification
Central hot water system (No. 1) gas-fired boiler Piping insulation (ringmain & supply risers):(a) Piping external to building: R0.6 (~25 mm);(b) Piping internal to building: R0.6 (~25 mm)
Pool (No. 1) Heating source: gas Pump controlled by timer: yes
Sauna (No. 1) Heating source: gas Efficiency measure: manual on / timer off
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 21/22
Notes
1. In these commitments, "applicant" means the person carrying out the development.
2. The applicant must identify each dwelling, building and common area listed in this certificate, on the plans accompanying any development application, and on the plans andspecifications accompanying the application for a construction certificate / complying development certificate, for the proposed development, using the same identifying letter orreference as is given to that dwelling, building or common area in this certificate.
3. This note applies if the proposed development involves the erection of a building for both residential and non-residential purposes (or the change of use of a building for bothresidential and non-residential purposes). Commitments in this certificate which are specified to apply to a "common area" of a building or the development, apply only to that part ofthe building or development to be used for residential purposes.
4. If this certificate lists a central system as a commitment for a dwelling or building, and that system will also service any other dwelling or building within the development, then thatsystem need only be installed once (even if it is separately listed as a commitment for that other dwelling or building).
5. If a star or other rating is specified in a commitment, this is a minimum rating.
6. All alternative water systems to be installed under these commitments (if any), must be installed in accordance with the requirements of all applicable regulatory authorities. NOTE:NSW Health does not recommend that stormwater, recycled water or private dam water be used to irrigate edible plants which are consumed raw, or that rainwater be used forhuman consumption in areas with potable water supply.
Legend
1. Commitments identified with a "✓" in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if adevelopment application is to be lodged for the proposed development).
2. Commitments identified with a "✓" in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a constructioncertificate / complying development certificate for the proposed development.
3. Commitments identified with a "✓" in the "Certifier check" column must be certified by a certifying authority as having been fulfilled. (Note: a certifying authority must not issue anoccupation certificate (either interim or final) for a building listed in this certificate, or for any part of such a building, unless it is satisfied that each of the commitments whose fulfilmentit is required to monitor in relation to the building or part, has been fulfilled).
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237202M_02 Friday, 11 September 2009 page 22/22
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Assessor Certificate Multiple Dwellings
Certificate Version 6.1. Prior versions not valid after 1 March 2006 Issued in accordance with
BASIX Thermal Comfort Simulation Method.
Assessor Name: Tracey Cools Company: Efficient Living ABSA #: 20101 Address: 24B, 176 South Creek Road, Cromer Phone: 9971 0003 Fax: 9971 0003 Email: [email protected] Declaration of interest: NoneClient Name: Tom Hutchison Company: Meriton Apartments Pty Ltd Address: Level 11, 528 Kent Street Sydney 2000 Phone: 9287 2888 Fax: 9287 2777 Email: [email protected] Project Address: 5 Loftus Street, ARNCLIFFE NSW 2205 LOT / DP: 101 / 706950 Applicant: Meriton Apartments Pty Ltd LGA: Rockdale City Council Assessment Date: 10/09/09 File ref: - Software: NatHERS Version: 2.32B Documentation All details, upon which this assessment has been based, are included in the project documentation that has been stamped and signed by the Assessor issuing this certificate, as identified below:Thermal Performance Spec: Cover sheet Drawings: parking 1, 1A, 2, G/1,2,3,4,5,6,7,8, roof, site, elevations - Issued 09/09/09
Affix assessor stamp
Building Specifications: Only specifications, detailed on Drawings identified above, have been referencedABSA Assessor Certificate Assessor # 20101 Certificate # 87815115 Issued: 11/09/09
Thermal performance specifications Page 1 of 2Floor area (M2) Predict. loads (MJ/M2/y)
Unit number(s) Certificate number Cond. Uncond. Heat Cool
(Sens & Lat)Concessions
Qualify for ventilation
bonus
B150 87815115 77.5 0 83 18 No No
B151 32779649 76 0 95 29 No No
B152 47672449 109 0 95 29 No No
B153 56764285 109 0 79 19 No No
B154 56764285 109 0 79 19 No No
B155 56764285 109 0 79 19 No No
B156 74447518 111 0 73 23 No No
B157 86807574 61 0 73 17 No No
B158 15443696 84 0 123 59 No No
B159 53866825 57 0 66 31 No No
B160 57111387 76 0 72 39 No No
B161 31823245 91 0 89 69 No No
B162 21162981 91 0 125 56 No No
B163 95544984 66 0 106 35 No No
B250 86807574 61 0 73 17 No No
B251 15443696 84 0 123 59 No No
87815115
11/09/09
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Thermal Performance SpecificationsThese are the Specifications upon which the Certified Assessment is based. If details included in these Specifications vary from other drawings or written specifications, these Specifications shall take precedence. If only one specification option is detailed for a building element, that specification must apply to all instances of that element for the project. If alternate specifications are detailed for a building element, the location and extent of alternate specifications must be detailed below and / or clearly indicated on referenced documents Windows Product ID Glass Frame U value SHGC Area M2 Detail
Supplier not specified Single Light grey low-E Aluminium 4.6 0.360 Varying To units listed on the upgrade table
Supplier not specified Single Light grey tint Aluminium 6.6 0.529 Varying To the remainder of the complex
Skylights Product ID Glass Frame U value SHGC Area M2 DetailNone Window and skylight U and SHGC values, if specified, are according to ANAC 2005. Alternate products or specifications may be used if their U value is lower, and the SHGC value is less than 10% higher or lower, than the U and SHGC values of the product specified above.External walls Construction Insulation Colour – solar abs. DetailPrecast concrete Foil (Sisalation) Not specified To units listed on the upgrade table Precast concrete None Not specified To the remainder of the complex Internal walls Construction Insulation DetailPlasterboard on studs None With-in each unit Hebel None To inter-tenancy walls Floors Construction Insulation Covering DetailConcrete slab None Tiles to wet areas & entry Carpet to Living rooms & bedrooms Ceilings Construction Insulation Detail Plasterboard R2.0 To top floor units & where exposed balcony is above Plasterboard None Where neighbouring units are above Roof Construction Insulation Colour – solar abs. DetailConcrete slab roof Foil (Sisalation) Light -SA <0.475 Top floor units & where exposed balcony is above Window cover Internal (curtains) External (awnings, shutters, etc) Not specified None
Varying eaves widths and offsets, as per plans Overshadowing from units above Overshadowing Overshadowing structures Overshadowing trees Adjacent Buildings No
Orientation, Exposure, Ventilation and InfiltrationOrientation of nominal north: Varying as per plan ABSA Assessor stamp Terrain category: Suburban Roof ventilation: Unventilated Cross ventilation: Standard Subfloor: Above carparks & neighbouring units Living area open to entry: No Doors separate living areas: No Stair open to heated areas: Varying Seals to windows and doors: Yes Exhaust fans without dampers: No Ventilated skylights: No Open fire, unflued gas heat: No Vented downlights: No Wall and ceiling vents: No
87815115
11/09/09
Certificate number: 235406M_02
This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated29/06/2006 published by the Department of Planning. This document is available atwww.basix.nsw.gov.au
This certificate is a revision of certificate number 235406M lodged with the consentauthority or certifier on 12 March 2009 with application 307/2009.
It is the responsibility of the applicant to verify with the consent authority that theoriginal, or any revised certificate, complies with the requirements of Schedule 1Clause 2A, 4A or 6A of the Environmental Planning and Assessment Regulation2000
Director-GeneralDate of issue: Friday, 11 September 2009
NSW GOVERNMENTDepartment of Planning
Score
✓ Water: 41 (Target 40)
✓ Thermal comfort: pass (Target pass)
✓ Energy: 20 (Target 20)
Project addressProject name Loftus Residential Development - Bui_02
Street address 5 Loftus Street Street Arncliffe 2205
Local Government Area Rockdale City Council
Plan type and plan number deposited 706950
Lot no. 101
Section no. -
Project typeNo. of unit buildings 1
No. of units in unit buildings 56
No. of attached dwelling houses 0
No. of separate dwelling houses 0
Site detailsSite area (m²) 16319
Roof area (m²) 890
Non-residential floor area (m²) 0
Residential car spaces 89
Non-residential car spaces 13
Common area landscapeCommon area lawn (m²) 440
Common area garden (m²) 443
Area of indigenous or low water usespecies (m²)
0
Assessor detailsAssessor number 20101
Certificate number 87815115
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 1/17
Description of project
The tables below describe the dwellings and common areas within the project
Unit building - Building B, 56 dwellings, 7 storeys above ground
(b) Common areas and central systems/facilities(i) Water(ii) Energy
2. Commitments for attached dwelling houses
3. Commitments for separate dwelling houses
4. Commitments for common areas and central systems/facilities for the development (non-building specific)(i) Water(ii) Energy
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 4/17
Schedule of BASIX commitments
The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.
1. Commitments for unit building - Building B
(a) Dwellings
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).
✓ ✓
(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it. ✓ ✓
(d) The applicant must install an on-demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "Hot water recirculation" column of the table below. ✓ ✓
(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below. ✓ ✓
(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both). ✓(g) The pool or spa must be located as specified in the table. ✓ ✓(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling in
the table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.
✓ ✓ ✓
Fixtures Appliances Individual pool Individual spa
Dwellingno.
Allshower-heads
All toiletflushingsystems
Allkitchentaps
Allbathroomtaps
HWrecirculationor diversion
Allclotheswashers
All dish-washers
Volume(maxvolume)
Poolcover
Poollocation
Poolshaded
Volume(maxvolume)
Spacover
Spashaded
Alldwellings
3 star 4 star 4 star 4 star no 2 star 3 star - - - - - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 5/17
Alternative water source
Dwelling no. Alternative watersupply systems
Size Configuration Landscapeconnection
Toiletconnection(s)
Laundryconnection
Pooltop-up
Spa top-up
None - - - no no no no no
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.
✓ ✓ ✓
(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table. ✓ ✓
(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system system is specified in the table for "Living areas" or "Bedroom areas", then no systems may beinstalled in any such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide forday/night zoning between living areas and bedrooms.
✓ ✓
(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.
✓ ✓
(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.
✓ ✓ ✓
(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:
(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and ✓
(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump. ✓
(h) The applicant must install in the dwelling:
(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below; ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 6/17
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and ✓ ✓
(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table. ✓(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "well
ventilated". ✓
Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system
Dwellingno.
Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control
Alldwellings
central hot watersystem 1
individual fan, ductedto façade or roof
manual switch on/off individual fan, notducted
manual switch on/off individual fan, ductedto façade or roof
Individual pool Individual spa Appliances & other efficiency measures
Dwellingno.
Pool heatingsystem
Timer Spa heatingsystem
Timer Kitchencooktop/oven
Refrigerator Wellventilatedfridgespace
Dishwasher Clotheswasher
Clothesdryer
Indoor orshelteredclothesdrying line
Privateoutdoor orunshelteredclothesdrying line
Alldwellings
- - - - gas cooktop &electric oven
- yes 3 star - 2 star yes no
(iii) Thermal Comfort Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.
(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.
(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 9/17
(iii) Thermal Comfort Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.
(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.
(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.
✓ ✓
(g) Commitment (h) below, applies to the rooms or areas of a dwelling which are listed in the "Cross Ventilation" table below ascomprising a breeze path for the dwelling.
(h) The applicant must construct the dwelling so that at least one ventilation opening is provided in each such room or area. (If onlyone room or area of a dwelling is mentioned for a breeze path, then that room or area must have at least two ventilationopenings).
✓ ✓
(i) The two ventilation openings referred to in (h), must meet the following specifications:
(aa) be located as specified for the breeze path in the table;
(bb) not be more than 15 metres apart;
(cc) if the dwelling is below the 10th storey of the building, be at least 1 square metre in size, or if the dwelling is on or abovethe 10th storey, be at least 0.5 square metres in size and be located above door head level in the room; and
(dd) have only 1 doorway, or opening less than 2 square metres in size, located in the direct path between them.
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
B163 106 35 35.0
B352 98 29 29.0
B450 81 17 17.0
B451 110 52 52.0
B452 78 38 38.0
B453 81 39 39.0
B454 96 68 68.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 10/17
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
B455 33 56 56.0
B456 122 45 45.0
B550 127 44 44.0
B551 85 60 60.0
B552 124 56 56.0
B553 58 38 38.0
B554 81 23 23.0
B555 130 45 45.0
B556 130 44 44.0
B650 125 59 59.0
B651 99 59 59.0
B652 113 50 50.0
B653 68 36 36.0
B654 92 22 22.0
B655 113 28 28.0
B656 127 22 22.0
B150, B350 83 18 18.0
B156, B356 73 23 23.0
B256, B363 106 46 46.0
B151, B152, B351 95 29 29.0
B153, B154, B155 79 19 19.0
B157, B250, B357 73 17 17.0
B158, B251, B358 123 59 59.0
B159, B252, B359 66 31 31.0
B160, B253, B360 72 39 39.0
B161, B254, B361 89 69 69.0
B162, B255, B362 125 56 56.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 11/17
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 12/17
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 13/17
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Lift car (No. 1) - - compact fluorescent connected to lift call button No
Central energy systems Type Specification
Lift (No. 1) gearless traction with V V VF motor
Number of levels (including basement): 8
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 14/17
4. Commitments for common areas and central systems/facilities for the development (non-building specific)
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
Central systems Size Configuration Connection (to allow for...)
Central water tank -rainwater or stormwater (No.1)
5000 To collect run-off from at least:- 890 square metres of roof area of buildings in the
development- 0 square metres of impervious area in the development- 0 square metres of garden/lawn area in the development- 0 square metres of planter box area in the development(excluding, in each case, any area which drains to, orsupplies, any other alternative water supply system).
- irrigation of 880 square metres of common landscapedarea on the site- car washing in 1 car washing bays on the site
Fire sprinkler system (No. 1) - So that fire sprinkler test water is contained within the firesprinkler system for re-use, rather than disposed.
-
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 15/17
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Indoor pool &or spa area(25% of total)
ventilation (supply +exhaust)
time clock or BMS controlled compact fluorescent manual on / manual off No
Gym (25% of total area) air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Car park area (25% of totalarea)
ventilation (supply +exhaust)
carbon monoxide monitor +2-speed fan
fluorescent zoned switching with motionsensor
No
Switch / PLant / areas (25%of )
ventilation exhaust only interlocked to light fluorescent manual on / manual off No
Garbage room (25% of totalarea)
ventilation exhaust only - fluorescent manual on / manual off No
Hallway & lobby's ventilation supply only time clock or BMS controlled compact fluorescent zoned switching No
Central energy systems Type Specification
Central hot water system (No. 1) gas-fired boiler Piping insulation (ringmain & supply risers):(a) Piping external to building: R0.6 (~25 mm);(b) Piping internal to building: R0.6 (~25 mm)
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 16/17
Notes
1. In these commitments, "applicant" means the person carrying out the development.
2. The applicant must identify each dwelling, building and common area listed in this certificate, on the plans accompanying any development application, and on the plans andspecifications accompanying the application for a construction certificate / complying development certificate, for the proposed development, using the same identifying letter orreference as is given to that dwelling, building or common area in this certificate.
3. This note applies if the proposed development involves the erection of a building for both residential and non-residential purposes (or the change of use of a building for bothresidential and non-residential purposes). Commitments in this certificate which are specified to apply to a "common area" of a building or the development, apply only to that part ofthe building or development to be used for residential purposes.
4. If this certificate lists a central system as a commitment for a dwelling or building, and that system will also service any other dwelling or building within the development, then thatsystem need only be installed once (even if it is separately listed as a commitment for that other dwelling or building).
5. If a star or other rating is specified in a commitment, this is a minimum rating.
6. All alternative water systems to be installed under these commitments (if any), must be installed in accordance with the requirements of all applicable regulatory authorities. NOTE:NSW Health does not recommend that stormwater, recycled water or private dam water be used to irrigate edible plants which are consumed raw, or that rainwater be used forhuman consumption in areas with potable water supply.
Legend
1. Commitments identified with a "✓" in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if adevelopment application is to be lodged for the proposed development).
2. Commitments identified with a "✓" in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a constructioncertificate / complying development certificate for the proposed development.
3. Commitments identified with a "✓" in the "Certifier check" column must be certified by a certifying authority as having been fulfilled. (Note: a certifying authority must not issue anoccupation certificate (either interim or final) for a building listed in this certificate, or for any part of such a building, unless it is satisfied that each of the commitments whose fulfilmentit is required to monitor in relation to the building or part, has been fulfilled).
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235406M_02 Friday, 11 September 2009 page 17/17
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Assessor Certificate Multiple Dwellings
Certificate Version 6.1. Prior versions not valid after 1 March 2006 Issued in accordance with
BASIX Thermal Comfort Simulation Method.
Assessor Name: Tracey Cools Company: Efficient Living ABSA #: 20101 Address: 24B, 176 South Creek Road, Cromer Phone: 9971 0003 Fax: 9971 0003 Email: [email protected] Declaration of interest: NoneClient Name: Tom Hutchison Company: Meriton Apartments Pty Ltd Address: Level 11, 528 Kent Street Sydney 2000 Phone: 9287 2888 Fax: 9287 2777 Email: [email protected] Project Address: 5 Loftus Street, ARNCLIFFE NSW 2205 LOT / DP: 101 / 706950 Applicant: Meriton Apartments Pty Ltd LGA: Rockdale City Council Assessment Date: 10/09/09 File ref: - Software: NatHERS Version: 2.32B Documentation All details, upon which this assessment has been based, are included in the project documentation that has been stamped and signed by the Assessor issuing this certificate, as identified below:Thermal Performance Spec: Cover sheet Drawings: parking 1, 1A, 2, G/1,2,3,4,5,6,7,8, roof, site, elevations - Issued 09/09/09
Affix assessor stamp
Building Specifications: Only specifications, detailed on Drawings identified above, have been referencedABSA Assessor Certificate Assessor # 20101 Certificate # 93201820 Issued: 11/09/09
Thermal performance specifications Page 1 of 3Floor area (M2) Predict. loads (MJ/M2/y)
Unit number(s) Certificate number Cond. Uncond. Heat Cool
(Sens & Lat)Concessions
Qualify for ventilation
bonus
CG01 93201820 53 0 113 28 No No
CG02 85134744 102 0 81 22 No No
CG03 85134744 102 0 81 22 No No
CG04 45141552 102 0 84 14 No No
CG05 45141552 102 0 84 14 No No
CG06 45141552 102 0 84 14 No No
CG07 48623418 108 0 116 53 No No
CG08 35437262 81.5 0 90 11 No No
CG09 78818671 81.5 0 90 11 No No
CG10 32066308 80 0 77 43 No No
CG11 34540856 81.5 0 97 21 No No
CG12 57188145 79 0 72 76 Yes Yes
CG13 23383531 81 0 74 28 No No
CG14 89543696 54 0 51 46 No No
CG15 26614137 76 0 87 24 No No
CG16 98648884 80 0 113 43 No No
93201820
11/09/09
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Thermal Performance SpecificationsThese are the Specifications upon which the Certified Assessment is based. If details included in these Specifications vary from other drawings or written specifications, these Specifications shall take precedence. If only one specification option is detailed for a building element, that specification must apply to all instances of that element for the project. If alternate specifications are detailed for a building element, the location and extent of alternate specifications must be detailed below and / or clearly indicated on referenced documents Windows Product ID Glass Frame U value SHGC Area M2 Detail
Supplier not specified Single Light grey low-E Aluminium 4.6 0.360 Varying To units listed on the upgrade table
Supplier not specified Single Light grey tint Aluminium 6.6 0.529 Varying To the remainder of the complex
Skylights Product ID Glass Frame U value SHGC Area M2 DetailNone Window and skylight U and SHGC values, if specified, are according to ANAC 2005. Alternate products or specifications may be used if their U value is lower, and the SHGC value is less than 10% higher or lower, than the U and SHGC values of the product specified above.External walls Construction Insulation Colour – solar abs. DetailPrecast concrete Foil (Sisalation) Not specified To units listed on the upgrade table Precast concrete None Not specified To the remainder of the complex Internal walls Construction Insulation DetailPlasterboard on studs None With-in each unit Hebel None To inter-tenancy walls Floors Construction Insulation Covering DetailConcrete slab None Tiles to wet areas & entry Carpet to Living rooms & bedrooms Ceilings Construction Insulation Detail Plasterboard R2.0 To top floor units & where exposed balcony is above Plasterboard None Where neighbouring units are above Roof Construction Insulation Colour – solar abs. DetailConcrete slab roof Foil (Sisalation) Light -SA <0.475 Top floor units & where exposed balcony is above Window cover Internal (curtains) External (awnings, shutters, etc) Not specified None
Varying eaves widths and offsets, as per plans Overshadowing from units above Overshadowing Overshadowing structures Overshadowing trees Adjacent Buildings No
Orientation, Exposure, Ventilation and InfiltrationOrientation of nominal north: Varying as per plan ABSA Assessor stamp Terrain category: Suburban Roof ventilation: Unventilated Cross ventilation: Standard Subfloor: Above carparks & neighbouring units Living area open to entry: No Doors separate living areas: No Stair open to heated areas: Varying Seals to windows and doors: Yes Exhaust fans without dampers: No Ventilated skylights: No Open fire, unflued gas heat: No Vented downlights: No Wall and ceiling vents: No
93201820
11/09/09
Certificate number: 237205M_02
This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated29/06/2006 published by the Department of Planning. This document is available atwww.basix.nsw.gov.au
This certificate is a revision of certificate number 237205M lodged with the consentauthority or certifier on 12 March 2009 with application 307/2009.
It is the responsibility of the applicant to verify with the consent authority that theoriginal, or any revised certificate, complies with the requirements of Schedule 1Clause 2A, 4A or 6A of the Environmental Planning and Assessment Regulation2000
Director-GeneralDate of issue: Friday, 11 September 2009
NSW GOVERNMENTDepartment of Planning
Score
✓ Water: 41 (Target 40)
✓ Thermal comfort: pass (Target pass)
✓ Energy: 20 (Target 20)
Project addressProject name Loftus Residential Development - Bui_02
Street address 5 Loftus Street Street ARNCLIFFE 2205
Local Government Area Rockdale City Council
Plan type and plan number deposited 706950
Lot no. 101
Section no. -
Project typeNo. of unit buildings 1
No. of units in unit buildings 65
No. of attached dwelling houses 0
No. of separate dwelling houses 0
Site detailsSite area (m²) 16319
Roof area (m²) 1035
Non-residential floor area (m²) 0
Residential car spaces 90
Non-residential car spaces 13
Common area landscapeCommon area lawn (m²) 440
Common area garden (m²) 443
Area of indigenous or low water usespecies (m²)
0
Assessor detailsAssessor number 20101
Certificate number 93201820
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 1/18
Description of project
The tables below describe the dwellings and common areas within the project
Unit building - Building C, 65 dwellings, 7 storeys above ground
(b) Common areas and central systems/facilities(i) Water(ii) Energy
2. Commitments for attached dwelling houses
3. Commitments for separate dwelling houses
4. Commitments for common areas and central systems/facilities for the development (non-building specific)(i) Water(ii) Energy
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 4/18
Schedule of BASIX commitments
The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.
1. Commitments for unit building - Building C
(a) Dwellings
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).
✓ ✓
(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it. ✓ ✓
(d) The applicant must install an on-demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "Hot water recirculation" column of the table below. ✓ ✓
(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below. ✓ ✓
(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both). ✓(g) The pool or spa must be located as specified in the table. ✓ ✓(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling in
the table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.
✓ ✓ ✓
Fixtures Appliances Individual pool Individual spa
Dwellingno.
Allshower-heads
All toiletflushingsystems
Allkitchentaps
Allbathroomtaps
HWrecirculationor diversion
Allclotheswashers
All dish-washers
Volume(maxvolume)
Poolcover
Poollocation
Poolshaded
Volume(maxvolume)
Spacover
Spashaded
Alldwellings
3 star 4 star 4 star 4 star no 2 star 3 star - - - - - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 5/18
Alternative water source
Dwelling no. Alternative watersupply systems
Size Configuration Landscapeconnection
Toiletconnection(s)
Laundryconnection
Pooltop-up
Spa top-up
None - - - - - - - -
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.
✓ ✓ ✓
(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table. ✓ ✓
(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system system is specified in the table for "Living areas" or "Bedroom areas", then no systems may beinstalled in any such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide forday/night zoning between living areas and bedrooms.
✓ ✓
(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.
✓ ✓
(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.
✓ ✓ ✓
(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:
(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and ✓
(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump. ✓
(h) The applicant must install in the dwelling:
(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below; ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 6/18
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and ✓ ✓
(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table. ✓(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "well
ventilated". ✓
Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system
Dwellingno.
Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control
Alldwellings
central hot watersystem 1
individual fan, ductedto façade or roof
manual switch on/off individual fan, notducted
manual switch on/off individual fan, ductedto façade or roof
Individual pool Individual spa Appliances & other efficiency measures
Dwellingno.
Pool heatingsystem
Timer Spa heatingsystem
Timer Kitchencooktop/oven
Refrigerator Wellventilatedfridgespace
Dishwasher Clotheswasher
Clothesdryer
Indoor orshelteredclothesdrying line
Privateoutdoor orunshelteredclothesdrying line
Alldwellings
- - - - gas cooktop &electric oven
- yes 3 star - 2 star yes no
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 9/18
(iii) Thermal Comfort Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.
(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.
(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.
(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.
(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.
(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.
✓ ✓
(g) Commitment (h) below, applies to the rooms or areas of a dwelling which are listed in the "Cross Ventilation" table below ascomprising a breeze path for the dwelling.
(h) The applicant must construct the dwelling so that at least one ventilation opening is provided in each such room or area. (If onlyone room or area of a dwelling is mentioned for a breeze path, then that room or area must have at least two ventilationopenings).
✓ ✓
(i) The two ventilation openings referred to in (h), must meet the following specifications:
(aa) be located as specified for the breeze path in the table;
(bb) not be more than 15 metres apart;
(cc) if the dwelling is below the 10th storey of the building, be at least 1 square metre in size, or if the dwelling is on or abovethe 10th storey, be at least 0.5 square metres in size and be located above door head level in the room; and
(dd) have only 1 doorway, or opening less than 2 square metres in size, located in the direct path between them.
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
C207 118 52 52.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 10/18
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
C315 95 23 23.0
C316 132 48 48.0
C401 106 57 39.9
C402 124 33 33.0
C403 119 34 34.0
C410 108 19 19.0
C413 24 59 59.0
C501 131 95 66.5
C502 135 49 49.0
C503 134 46 46.0
C510 126 19 19.0
C511 113 21 21.0
CG01 113 28 28.0
CG07 116 53 53.0
CG10 77 43 43.0
CG12 72 76 53.2
CG14 51 46 46.0
C202, C203 82 21 21.0
C313, C314 85 27 27.0
C412, C512 110 69 69.0
C504, C505 107 11 11.0
CG02, CG03 81 22 22.0
C101, C201, C301 118 23 23.0
C110, C210, C310 84 60 60.0
C112, C212, C312 82 68 47.6
C115, C215, CG15 87 24 24.0
C116, C216, CG16 113 43 43.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 11/18
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
C401 main living to Bedroom1Ventilation openings: >3 m apart andon adjacent external walls
main living to Bedroom2Ventilation openings: >3 m apart andon adjacent external walls
- -
C112, C501,CG12
main living to Bedroom1Ventilation openings: >3 m apart andon adjacent external walls
main living to Bedroom2Ventilation openings: >3 m apart andon adjacent external walls
within main living areaVentilation openings: >3 m apart andon adjacent external walls
-
C116, C212,C216, C312,C316, CG16
- - - -
All otherdwellings
- - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 12/18
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 13/18
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Lift car (No. 1) - - compact fluorescent connected to lift call button No
Lift car (No. 2) - - compact fluorescent connected to lift call button No
Office / Reception air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Hallway & lobby's ventilation supply only time clock or BMS controlled compact fluorescent zoned switching No
Central energy systems Type Specification
Lift (No. 1) gearless traction with V V VF motor
Number of levels (including basement): 8
Lift (No. 2) gearless traction with V V VF motor
Number of levels (including basement): 8
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 14/18
4. Commitments for common areas and central systems/facilities for the development (non-building specific)
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
Central systems Size Configuration Connection (to allow for...)
Central water tank -rainwater or stormwater (No.1)
5000 To collect run-off from at least:- 1035 square metres of roof area of buildings in the
development- 0 square metres of impervious area in the development- 0 square metres of garden/lawn area in the development- 0 square metres of planter box area in the development(excluding, in each case, any area which drains to, orsupplies, any other alternative water supply system).
- irrigation of 883 square metres of common landscapedarea on the site- car washing in 2 car washing bays on the site
Pool (No. 1) Volume: 60 kLs Location: Indoor pool & spa area (25% of total) -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 15/18
Central systems Size Configuration Connection (to allow for...)
Fire sprinkler system (No. 1) - So that fire sprinkler test water is contained within the firesprinkler system for re-use, rather than disposed.
-
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Indoor pool & spa area(25% of total)
ventilation (supply +exhaust)
time clock or BMS controlled compact fluorescent manual on / manual off No
Gym (25% of total area) air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Car park (percentage oftotal area)
ventilation exhaust only carbon monoxide monitor +2-speed fan
fluorescent zoned switching with motionsensor
No
Switch / Plant / Serviceareas (25% of)
ventilation exhaust only interlocked to light fluorescent manual on / manual off No
Garbage room (25% of totalarea)
ventilation exhaust only - fluorescent manual on / manual off No
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 16/18
Central energy systems Type Specification
Central hot water system (No. 1) gas-fired boiler Piping insulation (ringmain & supply risers):(a) Piping external to building: R0.6 (~25 mm);(b) Piping internal to building: R0.6 (~25 mm)
Pool (No. 1) Heating source: gas Pump controlled by timer: yes
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 17/18
Notes
1. In these commitments, "applicant" means the person carrying out the development.
2. The applicant must identify each dwelling, building and common area listed in this certificate, on the plans accompanying any development application, and on the plans andspecifications accompanying the application for a construction certificate / complying development certificate, for the proposed development, using the same identifying letter orreference as is given to that dwelling, building or common area in this certificate.
3. This note applies if the proposed development involves the erection of a building for both residential and non-residential purposes (or the change of use of a building for bothresidential and non-residential purposes). Commitments in this certificate which are specified to apply to a "common area" of a building or the development, apply only to that part ofthe building or development to be used for residential purposes.
4. If this certificate lists a central system as a commitment for a dwelling or building, and that system will also service any other dwelling or building within the development, then thatsystem need only be installed once (even if it is separately listed as a commitment for that other dwelling or building).
5. If a star or other rating is specified in a commitment, this is a minimum rating.
6. All alternative water systems to be installed under these commitments (if any), must be installed in accordance with the requirements of all applicable regulatory authorities. NOTE:NSW Health does not recommend that stormwater, recycled water or private dam water be used to irrigate edible plants which are consumed raw, or that rainwater be used forhuman consumption in areas with potable water supply.
Legend
1. Commitments identified with a "✓" in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if adevelopment application is to be lodged for the proposed development).
2. Commitments identified with a "✓" in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a constructioncertificate / complying development certificate for the proposed development.
3. Commitments identified with a "✓" in the "Certifier check" column must be certified by a certifying authority as having been fulfilled. (Note: a certifying authority must not issue anoccupation certificate (either interim or final) for a building listed in this certificate, or for any part of such a building, unless it is satisfied that each of the commitments whose fulfilmentit is required to monitor in relation to the building or part, has been fulfilled).
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 237205M_02 Friday, 11 September 2009 page 18/18
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Assessor Certificate Multiple Dwellings
Certificate Version 6.1. Prior versions not valid after 1 March 2006 Issued in accordance with
BASIX Thermal Comfort Simulation Method.
Assessor Name: Tracey Cools Company: Efficient Living ABSA #: 20101 Address: 24B, 176 South Creek Road, Cromer Phone: 9971 0003 Fax: 9971 0003 Email: [email protected] Declaration of interest: NoneClient Name: Tom Hutchison Company: Meriton Apartments Pty Ltd Address: Level 11, 528 Kent Street Sydney 2000 Phone: 9287 2517 Fax: 9287 2777 Email: [email protected] Project Address: 5 Loftus Street, ARNCLIFFE NSW 2205 LOT / DP: 101 / 706950 Applicant: Meriton Apartments Pty Ltd LGA: Rockdale City Council Assessment Date: 09/09/09 File ref: - Software: NatHERS Version: 2.32B Documentation All details, upon which this assessment has been based, are included in the project documentation that has been stamped and signed by the Assessor issuing this certificate, as identified below:Thermal Performance Spec: Cover sheet Drawings: parking 1, 1A, 2, G/1,2,3,4,5,6,7,8, roof, site, elevations - Issued 09/09/09
Affix assessor stamp
Building Specifications: Only specifications, detailed on Drawings identified above, have been referencedABSA Assessor Certificate Assessor # 20101 Certificate # 51643478 Issued: 11/09/09
Thermal performance specifications Page 1 of 3Floor area (M2) Predict. loads (MJ/M2/y)Unit
number(s) Certificate
number Cond. Uncond. Heat Cool (Sens & Lat)
Concessions Qualify for ventilation bonus
DG17 51643478 80.0 0.0 80.0 53.0 No No
DG18 68724714 93.0 0.0 95.0 34.0 Yes Yes
DG19 55074365 81.0 0.0 78.0 27.0 No No
DG20 73951109 121.0 0.0 79.0 57.0 No No
DG21 52206783 87.0 0.0 125.0 56.0 No No
DG22 46134371 47.0 0.0 69.0 58.0 No No
DG24 77116783 55.0 0.0 78.0 29.0 No No
DG25 55074365 81.0 0.0 78.0 27.0 No No
DG26 68724714 93.0 0.0 95.0 34.0 Yes Yes
51643478
11/09/09
ABSA Inc. Level 11 Elizabeth Towers 418A Elizabeth St Surry Hills NSW 2010 phone: 1300 760 012 fax: (02) 9281 9514 email: [email protected] www.absa.net.au
Thermal Performance SpecificationsThese are the Specifications upon which the Certified Assessment is based. If details included in these Specifications vary from other drawings or written specifications, these Specifications shall take precedence. If only one specification option is detailed for a building element, that specification must apply to all instances of that element for the project. If alternate specifications are detailed for a building element, the location and extent of alternate specifications must be detailed below and / or clearly indicated on referenced documents Windows Product ID Glass Frame U value SHGC Area M2 Detail
Supplier not specified Single Light grey low-E Aluminium 4.6 0.360 Varying To units listed on the upgrade table
Supplier not specified Single Light grey tint Aluminium 6.6 0.529 Varying To the remainder of the complex
Skylights Product ID Glass Frame U value SHGC Area M2 DetailNone Window and skylight U and SHGC values, if specified, are according to ANAC 2005. Alternate products or specifications may be used if their U value is lower, and the SHGC value is less than 10% higher or lower, than the U and SHGC values of the product specified above.External walls Construction Insulation Colour – solar abs. DetailPrecast concrete Foil (Sisalation) Not specified To units listed on the upgrade table Precast concrete None Not specified To the remainder of the complex Internal walls Construction Insulation DetailPlasterboard on studs None With-in each unit Hebel None To inter-tenancy walls Floors Construction Insulation Covering DetailConcrete slab None Tiles to wet areas & entry Carpet to Living rooms & bedrooms Ceilings Construction Insulation Detail Plasterboard R2.0 To top floor units & where exposed balcony is above Plasterboard None Where neighbouring units are above Roof Construction Insulation Colour – solar abs. DetailConcrete slab roof Foil (Sisalation) Light -SA <0.475 Top floor units & where exposed balcony is above Window cover Internal (curtains) External (awnings, shutters, etc) Not specified None
Varying eaves widths and offsets, as per plans Overshadowing from units above Overshadowing Overshadowing structures Overshadowing trees Adjacent Buildings No
Orientation, Exposure, Ventilation and InfiltrationOrientation of nominal north: Varying as per plan ABSA Assessor stamp Terrain category: Suburban Roof ventilation: Unventilated Cross ventilation: Standard Subfloor: Above carparks & neighbouring units Living area open to entry: No Doors separate living areas: No Stair open to heated areas: Varying Seals to windows and doors: Yes Exhaust fans without dampers: No Ventilated skylights: No Open fire, unflued gas heat: No Vented downlights: No Wall and ceiling vents: No
51643478
11/09/09
Certificate number: 235350M_02
This certificate confirms that the proposed development will meet the NSWgovernment's requirements for sustainability, if it is built in accordance with thecommitments set out below. Terms used in this certificate, or in the commitments,have the meaning given by the document entitled "BASIX Definitions" dated29/06/2006 published by the Department of Planning. This document is available atwww.basix.nsw.gov.au
This certificate is a revision of certificate number 235350M lodged with the consentauthority or certifier on 12 March 2009 with application 307/2009.
It is the responsibility of the applicant to verify with the consent authority that theoriginal, or any revised certificate, complies with the requirements of Schedule 1Clause 2A, 4A or 6A of the Environmental Planning and Assessment Regulation2000
Director-GeneralDate of issue: Friday, 11 September 2009
NSW GOVERNMENTDepartment of Planning
Score
✓ Water: 41 (Target 40)
✓ Thermal comfort: pass (Target pass)
✓ Energy: 20 (Target 20)
Project addressProject name Loftus Residential Development - Bui_02
Street address 5 Loftus Street Street Arncliffe 2205
Local Government Area Rockdale City Council
Plan type and plan number deposited 706950
Lot no. 101
Section no. -
Project typeNo. of unit buildings 1
No. of units in unit buildings 90
No. of attached dwelling houses 0
No. of separate dwelling houses 0
Site detailsSite area (m²) 16319
Roof area (m²) 1980
Non-residential floor area (m²) 0
Residential car spaces 89
Non-residential car spaces 13
Common area landscapeCommon area lawn (m²) 440
Common area garden (m²) 443
Area of indigenous or low water usespecies (m²)
0
Assessor detailsAssessor number 20101
Certificate number 51643478
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 1/26
Description of project
The tables below describe the dwellings and common areas within the project
Unit building - Building D, 90 dwellings, 7 storeys above ground
(b) Common areas and central systems/facilities(i) Water(ii) Energy
2. Commitments for attached dwelling houses
3. Commitments for separate dwelling houses
4. Commitments for common areas and central systems/facilities for the development (non-building specific)(i) Water(ii) Energy
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 5/26
Schedule of BASIX commitments
The commitments set out below regulate how the proposed development is to be carried out. It is a condition of any development consent granted, or complyingdevelopment certificate issued, for the proposed development, that BASIX commitments be complied with.
1. Commitments for unit building - Building D
(a) Dwellings
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must plant indigenous or low water use species of vegetation throughout the area of land specified for the dwellingin the "Indigenous species" column of the table below, as private landscaping for that dwelling. (This area of indigenous vegetationis to be contained within the "Area of garden and lawn" for the dwelling specified in the "Description of Project" table).
✓ ✓
(c) If a rating is specified in the table below for a fixture or appliance to be installed in the dwelling, the applicant must ensure thateach such fixture and appliance meets the rating specified for it. ✓ ✓
(d) The applicant must install an on-demand hot water recirculation system which regulates all hot water use throughout the dwelling,where indicated for a dwelling in the "Hot water recirculation" column of the table below. ✓ ✓
(e) The applicant must not install a private swimming pool or spa for the dwelling, with a volume exceeding that specified for it in thetable below. ✓ ✓
(f) If specified in the table, that pool or spa (or both) must have a pool cover or shading (or both). ✓(g) The pool or spa must be located as specified in the table. ✓ ✓(h) The applicant must install, for the dwelling, each alternative water supply system, with the specified size, listed for that dwelling in
the table below. Each system must be configured to collect run-off from the areas specified (excluding any area which suppliesany other alternative water supply system), and to divert overflow as specified. Each system must be connected as specified.
✓ ✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 6/26
Fixtures Appliances Individual pool Individual spa
3 star 4 star 4 star 4 star no 2 star 3 star - - - - - - -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 9/26
Fixtures Appliances Individual pool Individual spa
Dwellingno.
Allshower-heads
All toiletflushingsystems
Allkitchentaps
Allbathroomtaps
HWrecirculationor diversion
Allclotheswashers
All dish-washers
Volume(maxvolume)
Poolcover
Poollocation
Poolshaded
Volume(maxvolume)
Spacover
Spashaded
D517,D518,D520,D624,DG17,DG18,DG24,DG26,DG27
Alternative water source
Dwelling no. Alternative watersupply systems
Size Configuration Landscapeconnection
Toiletconnection(s)
Laundryconnection
Pooltop-up
Spa top-up
None - - - no no no no no
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must comply with the commitments listed below in carrying out the development of a dwelling listed in a table below.
(b) The applicant must install each hot water system specified for the dwelling in the table below, so that the dwelling’s hot water issupplied by that system. If the table specifies a central hot water system for the dwelling, then the applicant must connect thatcentral system to the dwelling, so that the dwelling’s hot water is supplied by that central system.
✓ ✓ ✓
(c) The applicant must install, in each bathroom, kitchen and laundry of the dwelling, the ventilation system specified for that room inthe table below. Each such ventilation system must have the operation control specified for it in the table. ✓ ✓
(d) The applicant must install the cooling and heating system/s specified for the dwelling under the "Living areas" and "Bedroomareas" headings of the "Cooling" and "Heating" columns in the table below, in/for at least 1 living/bedroom area of the dwelling. Ifno cooling or heating system system is specified in the table for "Living areas" or "Bedroom areas", then no systems may beinstalled in any such areas. If the term "zoned" is specified beside an air conditioning system, then the system must provide forday/night zoning between living areas and bedrooms.
✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 10/26
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(e) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Artificial lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that the "primary type of artificiallighting" for each such room in the dwelling is fluorescent lighting or light emitting diode (LED) lighting. If the term "dedicated" isspecified for a particular room or area, then the light fittings in that room or area must only be capable of being used forfluorescent lighting or light emitting diode (LED) lighting.
✓ ✓
(f) This commitment applies to each room or area of the dwelling which is referred to in a heading to the "Natural lighting" column ofthe table below (but only to the extent specified for that room or area). The applicant must ensure that each such room or area isfitted with a window and/or skylight.
✓ ✓ ✓
(g) This commitment applies if the applicant installs a water heating system for the dwelling’s pool or spa. The applicant must:
(aa) install the system specified for the pool in the "Individual Pool" column of the table below (or alternatively must not installany system for the pool). If specified, the applicant must install a timer, to control the pool's pump; and ✓
(bb) install the system specified for the spa in the "Individual Spa" column of the table below (or alternatively must not installany system for the spa). If specified, the applicant must install a timer to control the spa's pump. ✓
(h) The applicant must install in the dwelling:
(aa) the kitchen cook-top and oven specified for that dwelling in the "Appliances & other efficiency measures" column of thetable below; ✓
(bb) each appliance for which a rating is specified for that dwelling in the "Appliances & other efficiency measures" column ofthe table, and ensure that the appliance has that minimum rating; and ✓ ✓
(cc) any clothes drying line specified for the dwelling in the "Appliances & other efficiency measures" column of the table. ✓(i) If specified in the table, the applicant must carry out the development so that each refrigerator space in the dwelling is "well
ventilated". ✓
Hot water Bathroom ventilation system Kitchen ventilation system Laundry ventilation system
Dwellingno.
Hot water system Each bathroom Operation control Each kitchen Operation control Each laundry Operation control
Alldwellings
central hot watersystem 1
individual fan, ductedto façade or roof
manual switch on/off individual fan, notducted
manual switch on/off individual fan, ductedto façade or roof
manual on / timer off
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 11/26
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 17/26
(iii) Thermal Comfort Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) The applicant must attach the certificate referred to under "Assessor details" on the front page of this BASIX certificate (the"Assessor Certificate") to the development application and construction certificate application for the proposed development (or, ifthe applicant is applying for a complying development certificate for the proposed development, to that application). The applicantmust also attach the Assessor Certificate to the application for a final occupation certificate for the proposed development.
(b) The Assessor Certificate must have been issued by an Accredited Assessor in accordance with the Thermal Comfort Protocol.
(c) The details of the proposed development on the Assessor Certificate must be consistent with the details shown in this BASIXCertificate, including the details shown in the "Thermal Loads" table below.
(d) The applicant must show on the plans accompanying the development application for the proposed development, all matterswhich the Thermal Comfort Protocol requires to be shown on those plans. Those plans must bear a stamp of endorsement fromthe Accredited Assessor, to certify that this is the case.
(e) The applicant must show on the plans accompanying the application for a construction certificate (or complying developmentcertificate, if applicable), all thermal performance specifications set out in the Assessor Certificate, and all aspects of the proposeddevelopment which were used to calculate those specifications.
(f) The applicant must construct the development in accordance with all thermal performance specifications set out in the AssessorCertificate, and in accordance with those aspects of the development application or application for a complying developmentcertificate which were used to calculate those specifications.
✓ ✓
(g) Commitment (h) below, applies to the rooms or areas of a dwelling which are listed in the "Cross Ventilation" table below ascomprising a breeze path for the dwelling.
(h) The applicant must construct the dwelling so that at least one ventilation opening is provided in each such room or area. (If onlyone room or area of a dwelling is mentioned for a breeze path, then that room or area must have at least two ventilationopenings).
✓ ✓
(i) The two ventilation openings referred to in (h), must meet the following specifications:
(aa) be located as specified for the breeze path in the table;
(bb) not be more than 15 metres apart;
(cc) if the dwelling is below the 10th storey of the building, be at least 1 square metre in size, or if the dwelling is on or abovethe 10th storey, be at least 0.5 square metres in size and be located above door head level in the room; and
(dd) have only 1 doorway, or opening less than 2 square metres in size, located in the direct path between them.
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
D120 74.0 28.0 28.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 18/26
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
D424 115.0 41.0 41.0
D425 112 61 61.0
D426 79 47 47.0
D427 98.0 43.0 43.0
D518 111.0 33.0 33.0
D524 76 37 37.0
D526 111 33 33.0
D527 100 42 42.0
D617 98 69 69.0
D618 93 42 42.0
D619 94 27 27.0
D620 91 56.0 56.0
D621 98 54 54.0
D622 100 57 57.0
D624 90.0 35.0 35.0
D625 125 34.0 34.0
D626 125 60 60.0
DG22 69 58 58.0
DG24 78.0 29.0 29.0
D124, D224, D324 99 41 41.0
D125, D225, D325 97 59 59.0
D126, D226, D326 66.0 46.0 46.0
D127, D227, D327 85 44 44.0
D128, D228, D328,D428
76.0 37.0 37.0
D123, D223, D323,D423, D523
86 57 57.0
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 19/26
Thermal loads
Dwelling no. Heating load (in mJ/m²/yr) Cooling load (in mJ/m²/yr) Corrected Cooling load (in mJ/m²/yr)
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 20/26
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 21/26
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Lift car (No. 1) - - compact fluorescent connected to lift call button No
Lift car (No. 2) - - compact fluorescent connected to lift call button No
Office / Reception air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Hallway & lobby's ventilation supply only time clock or BMS controlled compact fluorescent zoned switching No
Central energy systems Type Specification
Lift (No. 1) gearless traction with V V VF motor
Number of levels (including basement): 8
Lift (No. 2) gearless traction with V V VF motor
Number of levels (including basement): 8
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 22/26
4. Commitments for common areas and central systems/facilities for the development (non-building specific)
(b) Common areas and central systems/facilities
(i) Water Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a showerhead, toilet, tap or clothes washer into a common area, then thatitem must meet the specifications listed for it in the table. ✓ ✓
(b) The applicant must install (or ensure that the development is serviced by) the alternative water supply system(s) specified in the"Central systems" column of the table below. In each case, the system must be sized, be configured, and be connected, asspecified in the table.
✓ ✓ ✓
(c) A swimming pool or spa listed in the table must not have a volume (in kLs) greater than that specified for the pool or spa in thetable. ✓ ✓
(d) A pool or spa listed in the table must have a cover or shading if specified for the pool or spa in the table. ✓(e) The applicant must install each fire sprinkler system listed in the table so that the system is configured as specified in the table. ✓ ✓(f) The applicant must ensure that the central cooling system for a cooling tower is configured as specified in the table. ✓ ✓
Common area Showerheads rating Toilets rating Taps rating Clothes washers rating
All commonareas
3 star 4 star 4 star no common laundry facility
Central systems Size Configuration Connection (to allow for...)
Central water tank -rainwater or stormwater (No.1)
5000 To collect run-off from at least:- 1980 square metres of roof area of buildings in the
development- 0 square metres of impervious area in the development- 0 square metres of garden/lawn area in the development- 0 square metres of planter box area in the development(excluding, in each case, any area which drains to, orsupplies, any other alternative water supply system).
- irrigation of 883 square metres of common landscapedarea on the site- car washing in 1 car washing bays on the site
Pool (No. 1) Volume: 60 kLs Location: Indoor pool & spa area (25% of total) -
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 23/26
Central systems Size Configuration Connection (to allow for...)
Spa (No. 1) Volume: 7 kLs Location: Indoor pool & spa area (25% of total)Spa cover: yes
-
Fire sprinkler system (No. 1) - So that fire sprinkler test water is contained within the firesprinkler system for re-use, rather than disposed.
-
(ii) Energy Show onDA plans
Show on CC/CDCplans & specs
Certifiercheck
(a) If, in carrying out the development, the applicant installs a ventilation system to service a common area specified in the tablebelow, then that ventilation system must be of the type specified for that common area, and must meet the efficiency measurespecified.
✓ ✓
(b) In carrying out the development, the applicant must install, as the "primary type of artificial lighting" for each common areaspecified in the table below, the lighting specified for that common area. This lighting must meet the efficiency measure specified.The applicant must also install a centralised lighting control system or Building Management System (BMS) for the common area,where specified.
✓ ✓
(c) The applicant must install the systems and fixtures specified in the "Central energy systems" column of the table below. In eachcase, the system or fixture must be of the type, and meet the specifications, listed for it in the table. ✓ ✓ ✓
Common area ventilation system Common area lighting
Common area Ventilation system type Ventilation efficiencymeasure
Primary type of artificiallighting
Lighting efficiencymeasure
Lighting controlsystem/BMS
Indoor pool & spa area(25% of total)
ventilation (supply +exhaust)
time clock or BMS controlled compact fluorescent manual on / manual off No
Gym (25% of total area) air conditioning system time clock or BMS controlled compact fluorescent manual on / manual off No
Car park (25% of total area) ventilation (supply +exhaust)
carbon monoxide monitor +2-speed fan
fluorescent zoned switching with motionsensor
No
Switch / Plant / Serviceareas (25% of)
ventilation exhaust only interlocked to light fluorescent manual on / manual off No
Garbage rooms (25% oftotal area)
ventilation exhaust only - fluorescent manual on / manual off No
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 24/26
Central energy systems Type Specification
Central hot water system (No. 1) gas-fired storage(manifolded)
Piping insulation (ringmain & supply risers):(a) Piping external to building: R0.6 (~25 mm);(b) Piping internal to building: R0.6 (~25 mm)
Pool (No. 1) Heating source: no heating Pump controlled by timer: yes
Spa (No. 1) Heating system: no heating Pump controlled by timer: yes
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 25/26
Notes
1. In these commitments, "applicant" means the person carrying out the development.
2. The applicant must identify each dwelling, building and common area listed in this certificate, on the plans accompanying any development application, and on the plans andspecifications accompanying the application for a construction certificate / complying development certificate, for the proposed development, using the same identifying letter orreference as is given to that dwelling, building or common area in this certificate.
3. This note applies if the proposed development involves the erection of a building for both residential and non-residential purposes (or the change of use of a building for bothresidential and non-residential purposes). Commitments in this certificate which are specified to apply to a "common area" of a building or the development, apply only to that part ofthe building or development to be used for residential purposes.
4. If this certificate lists a central system as a commitment for a dwelling or building, and that system will also service any other dwelling or building within the development, then thatsystem need only be installed once (even if it is separately listed as a commitment for that other dwelling or building).
5. If a star or other rating is specified in a commitment, this is a minimum rating.
6. All alternative water systems to be installed under these commitments (if any), must be installed in accordance with the requirements of all applicable regulatory authorities. NOTE:NSW Health does not recommend that stormwater, recycled water or private dam water be used to irrigate edible plants which are consumed raw, or that rainwater be used forhuman consumption in areas with potable water supply.
Legend
1. Commitments identified with a "✓" in the "Show on DA plans" column must be shown on the plans accompanying the development application for the proposed development (if adevelopment application is to be lodged for the proposed development).
2. Commitments identified with a "✓" in the "Show on CC/CDC plans and specs" column must be shown in the plans and specifications accompanying the application for a constructioncertificate / complying development certificate for the proposed development.
3. Commitments identified with a "✓" in the "Certifier check" column must be certified by a certifying authority as having been fulfilled. (Note: a certifying authority must not issue anoccupation certificate (either interim or final) for a building listed in this certificate, or for any part of such a building, unless it is satisfied that each of the commitments whose fulfilmentit is required to monitor in relation to the building or part, has been fulfilled).
BASIX Department of Planning www.basix.nsw.gov.au Version: 5.75 / CASUARINA_2_0_11_0 Certificate No.: 235350M_02 Friday, 11 September 2009 page 26/26