Top Banner
Local Exhaust Fans
59

Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Dec 17, 2015

Download

Documents

Norma Webb
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Local Exhaust Fans

Page 2: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Local Exhaust Fans

Page 3: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Biological ContaminatesMoistureCombustion gases - If not burned properly can intro. CO.

Gas cooktopsGas ovensFurnaceGas Hot H20 heatersWoodstovesLeaky chimneys

Page 4: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Multi Point Ventilation

Page 5: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Heat Recovery Ventilator

Page 6: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

HRV

Page 7: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

HRV

Page 8: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Bath Ventilation

Page 9: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Bathroom Exhaust Fans

Page 10: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Bathroom Exhaust Fans

CODE for Baths with bathing or spas facilities:

Minimum 80 CFM Intermittent Ventilation required

orContinuous Ventilation System at 20 cfm

CODE for Toilet Rooms without bathing or spas facilities:

3SF Minimum Window ½ of which must be openable Minimum 50 CFM Intermittent Ventilation

Page 11: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Home Ventilation Institute Recommendations - Baths

Bathrooms to 80SF - 80CFM fan (Code) Bathrooms 81sf to 100 sf – 1 cfm per

square foot (~ 8 air changes/hour) Bathrooms over 100 sf add the CFM for

each fixture Allow 50 CFM per standard toilets, shower

and steam shower (put on timer) Allow 100 CFM per Whirlpool, garden and hot

tubs

HVI recommends continuous ventilations as augmentation to intermitent venilation

Page 12: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Bathroom Exhaust Fans

A toilet in its own enclosure should have its own fan

Fans approved for wet areas should be placed over or very near the shower or tub when possible.

Bath doors should be undercut at least 3/4”

Leave fan on for 20 minutes after use of the bathroom

Page 13: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Web Resource

HVACquick.com Home Ventilation Institute

Page 14: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Ventilation Considerations

Fan Type Propeller Fan – Limited air capacity and noisy

Axial Fan – Better air movement but still noisy

Centrifugal Blower (Squirrel Cage) The best

Page 15: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Propeller Fan

Page 16: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Axial Fan

Page 17: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Centrifugal Blower

Page 18: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Sound Levels

Sound is measured in Sones

1-Sone equals the loudness of a pure tone having a frequency of 1,000 hertz at 40 decibels.

Page 19: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Decibels

0 -The softest sound a person can hear with normal hearing

10 -Normal breathing 20 Whispering at 5 feet 30 Soft whisper 50 Rainfall 60 Normal conversation 110 Shouting in ear 120 Thunder .9 Sones = approx. 28.2 decibels

Page 20: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Sones

The Home Ventilation Institute sets a limit of 9.0 sones for kitchen fans up to 500 CFM

Reference – A fan with a sone rating of 8.0 sones is twice as loud as one rated at 4.0 sones.

Reference - Refrigerators run at about 1.0 sone.

Page 21: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 22: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

In-Line Ventilator Fan 110 CFM 1.0 Sones 210 CFM 2.0 Sones

Page 23: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Broan Silent Series 110 cfm .7 Sones

Page 24: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Switching Fans

Humidistat

Page 25: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Kitchen Ventilation

Page 26: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Kitchen Exhaust Fans

CODE (ASHRAE) The American Society of Heating, Refrigerating and Air-Conditioning Engineers

100 CFM IntermittentOr25 CFM Continuous

Page 27: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Home Ventilation Institute Recommendations - Kitchens

Wall Mount Hoods – 100 cfm per foot of width

Island Mount Hoods – 150 cfm per foot of width

Page 28: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Air Flow Rules of Thumb

Rule of Thumb 1:Take the hood area (in square feet) and multiply it by 75 to get the CFM (cubic feet per minute) for a wall hood, or multiply it by 100 for an island hood.

Rule of Thumb 2:Allow 15 air changes per hour (ACH) for the kitchen. Take the kitchen volume (length x width x height) and divide by 4 to get the required CFM.

Page 29: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Air Flow Rules of Thumb

Rule of Thumb 3:Allow 1 CFM per 100 BTU's per hour (BTUH) heat output.Take the output of the oven and cooktop (if together or close) and divide by 100 to get the required CFM.

Rule of Thumb 4: (this applies to commercial type ranges)Allow 100 CFM per linear foot of hood.Take the perimeter of the hood and multiply it by 100 to get the required CFM.

Which rule of thumb is the best one to use?The most popular rules of thumb are #1 and #3. We typically use rule of thumb #1 when we size fans.

Page 30: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

NKBA Recommendations

Page 31: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Multi Point Ventilation

Page 32: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Vented Hood System

Page 33: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Recirculating Fan in Microwave Combo

Page 34: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Kitchen Ventilation (HOGSS)

Heat Odor Grease Steam Smoke

Page 35: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Recirculating Range Hood

Page 36: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Recirculating Ventilation System

This type of system will only remove two Heat Steam

Page 37: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Downdraft

Page 38: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Down Draft Ventilation

Page 39: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Down Draft Ventilation

Page 40: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Range Hood Installation

Page 41: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 42: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 43: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 44: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 45: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 46: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 47: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 48: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 49: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
Page 50: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Integral Fan Vented Through Roof

Page 51: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

In Line Fan

Page 52: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Integral Through Soffit

Page 53: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Remote Ventilator

Page 54: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Through Crawlspace

Page 55: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Down Draft Through Floor

Page 56: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Down Draft Through Roof

Page 57: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Kitchen Ventilation Considerations

Fan – 300 CFM minimum Ducted Duct run lengths

Interior Fan (power) Keep duct runs as short and

straight as possible. 6” round or 3 ¼” x 10 rectangular

ducts Maximum run = 25’ maximum

Page 58: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.

Kitchen Ventilation Considerations

Exterior or In-Line Fan (power) 9” round or 3 ¼” x 14”

rectangular duct Maximum run = 55’ maximum

Page 59: Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.