Top Banner
LOAD CELL PRODUCTS CATALOGUE
30

LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: [email protected]

Jun 27, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

LOAD CELL PRODUCTSCATALOGUE

Page 2: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

2

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Page 3: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

3

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

PAGE

INTRODUCTION 4

SECTION 1 - LOAD CELLS 5

SELF INDICATING CELLS TYPE RRI-S 6

CABLED CELLS TYPE RRI-C 7

TELEMETRY CELLS TYPE RRI-T 8

SECTION 2 - ATEX / IECEx WIRELESS LOAD CELLS 11

SECTION 4 - LOAD SHACKLES 15

STANDARD LOAD SHACKLES 16

MARINE LOAD SHACKLES 17

SECTION 5 - COMPRESSION LOAD CELLS 18

SECTION 6 - RUNNING LINE MONITORS 22

SECTION 7 - CRANE SCALES 24

SECTION 8 - REPAIRS AND CALIBRATION 26

CONTENTS

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0 3

Page 4: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

4

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

At Red Rooster we design and manufacture a range of tensile digital load cells and load shackles up to 500 tonne and compressive load cells up to 1500 tonne.

The load cells can be supplied with various types of displays – self indicating, cabled and telemetry indicating (wireless display).

Options available include printer modules, large displays for cranes, PC interfaces and data logging to a spreadsheet with time and date.

The Red Rooster range of ATEX / IECEx wireless load cells have been developed to meet the requirements of our customers in hazardous industries where explosive gases or dusts may be present, such as the offshore industry, engineering and chemical industries, or wherever accurate measurement is required in a hazardous area.

Other types of load cells we offer include load pins, digital crane scales, hydrostatic crane scales and running line monitors.

With our inhouse design and manufacturing we can offer special units, such as weighing systems, weigh platforms, torque cells and much more – please contact us if you have a special requirement for a load measuring device.

Our test rigs allow us to calibrate up to 400 tonne in Aberdeen / 50 tonne in West Bromwich. They are fully calibrated and UKAS (NAMAS) traceable.

Our qualified technicians can repair and calibrate most other manufacturer’s load cells at our works. After inspection, a report and quotation is issued to enable the customer to decide on the viability of the repair. Once authorised by the customer, the repair is dealt with promptly and efficiently, to ensure a speedy return.

At Red Rooster, we also have a comprehensive range of load cells, load shackles, compression load cells and running line monitors available for hire, which are supplied fully calibrated and are available at short notice.

We welcome your enquiries for load cell sales and hires, and our dedicated sales team will assist you with your enquiry to offer the best solution for your requirements.

Digital data sheets and parts lists are available from our website: www.redroosterlifting.com

INTRODUCTION

Page 5: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

5

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

RRI-S SERIES ( 5 tonne - 25 tonne )

Our RRI-S range of self-indicating load cells has been developed from our well proven SWL range to meet the ever increasing requirements of our customers. The cells range in capacity from 5 tonne to 25 tonne, and are manufactured from low weight, high strength duralloy. All load cells are proof loaded to 150% of the rated capacity and have a safety factor of 5:1 (minimum) and IP65 ingress protection.

RRI-C SERIES ( 5 tonne - 500 tonne )

Our RRI-C range of cabled load cells has been developed from our well proven SWLD range to meet the ever increasing requirements of our customers. The cells are available across the full range in capacity from 5 tonne to 500 tonne, and are manufactured from low weight, high strength duralloy. All load cells are proof loaded to 150% of the rated capacity and have a safety factor of 5:1 (minimum) and IP68 ingress protection.The ergonomically designed handset, with tactile switch membrane, allows one handed operation and is environmentally sealed against water and dust to IP65. An easily accessible battery compartment allows the three “AA” batteries to be changed quickly.

RRI-T SERIES ( 5 tonne - 500 tonne )

Our RRI-T range of wireless load cells has been developed from our well proven SWLT range to meet the ever increasing requirements of our customers. The cells range in capacity from 5 tonne to 500 tonne, and are manufactured from low weight, high strength duralloy. All load cells are proof loaded to 150% of the rated capacity and have a safety factor of 5:1 (minimum) and IP68 ingress protection. The ergonomically designed handset, with tactile switch membrane, allows one handed operation and is environmentally sealed against water and dust to IP65. An easily accessible battery compartment allows the three “AA” batteries to be changed quickly. Both the cell and the handset are supplied in a single robust carry case for added protection up to 50 tonne.

LOAD CELLSRRI-S | RRI-C | RRI-T

Page 6: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

6

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Model A B C D E F ØGRRI-S5 225 125 290 60 25 32 27.5

RRI-S12.5 245 135 345 60 25 50 45RRI-S25 260 155 390 60 25 60 55

Technical SpecificationModel RRI-S5 RRI-S12.5 RRI-S25

Capacity 5 tonne 12.5 tonne 25 tonne

Shackle Size 6.5 tonne 13.5 tonne 25 tonne

Resolution 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Ingress Protection IP65Temp Range -10°C TO + 40°CCell Battery 6 x “AA” Alkaline batteriesCell Weight 2.5 kg 4.5 kg 6.5 kg

Cell with Case 6.5 kg 8.5 kg 10.5 kg

All measurements are in mm

Image for illustration purposes only

*Based on a BS1610 Grade 1 Calibration MachineInformation subject to change without notice

FUNCTIONS On/Off Tare Push button zero Low battery indicator Restricted access for programming Peak hold Select units in lbs, kg, tonne or US Tons

STANDARD FEATURES 11mm liquid crystal display Self-diagnostic (diagnoses fault with error code) Non-corruptible single point calibration 6 x “AA” Alkaline batteries Up to 24 hours** continuous use Robust carry case

OPTIONAL FEATURES Rechargeable Lithium battery with charger

**Depending on charge and conditions

Drawing represents 25 tonne model

SELF INDICATING LOAD CELLRRI-S | 5 TONNE TO 25 TONNE

Page 7: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

7

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Model A B C D E F ØGRRI-C5 225 125 290 60 25 32 27.5

RRI-C12.5 245 135 345 60 25 50 45RRI-C25 260 155 390 60 25 60 55RRI-C50 300 185 480 75 25 75 75

Technical SpecificationModel RRI-C5 RRI-C12.5 RRI-C25 RRI-C50

Capacity 5 tonne 12.5 tonne 25 tonne 50 tonneResolution 1 kg 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" AlkalineBattery Life Alkaline "AA" continuous use: Minimum 75 Hours**

Handset Display 8 digit x 8mm Shackle Size 6.5 tonne 13.5 tonne 25 tonne 55 tonneCell Weight 2.5 kg 4.5 kg 6.5 kg 13.0 kg

Cell with Case 6.5 kg 8.5kg 10.5 kg 19.0 kg

All measurements are in mm

*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Image for illustration purposes only

STANDARD FEATURES On/Off Tare Zero Peak hold Low battery indicator Battery level indicator 3 x "AA" Alkaline battery Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case 10m cable length from cell to handset

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode AA lithium batteries in handset for extended life Auto turn off after 5 minutes non use Backlit display

Drawing represents 25 tonne model

CABLED LOAD CELLRRI-C | 5 TONNE TO 50 TONNE

SELF INDICATING LOAD CELLRRI-S | 5 TONNE TO 25 TONNE

Page 8: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

8

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Technical SpecificationModel RRI-C100 RRI-C150 RRI-C200

Capacity 100 tonne 150 tonne 200 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 1.0% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" AlkalineCell Battery Life Alkaline "AA" continuous use: Minimum 75 Hours**Handset Display 8 digit x 8mm

Shackle Size 120 tonne 150 tonne 200 tonneCell Weight 50 kg 75 kg 95 kg

*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Model A B C D E ØGRRI-C100 450 300 700 120 25 100RRI-C150 520 325 820 135 25 120RRI-C200 540 350 890 150 25 145

All measurements are in mm

Image for illustration purposes only

STANDARD FEATURES On/Off Tare Zero Peak hold Low battery indicator Battery level indicator 3 x "AA" Alkaline battery Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case 10m cable length from cell to handset

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode Rechargeable lithium batteries in handset for extended life Auto turn off after 5 minutes non use Backlit display

CABLED LOAD CELLRRI-C | 100 TONNE TO 200 TONNE

Page 9: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

9

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

CABLED LOAD CELLRRI-C | 300 TONNE TO 400 TONNE

CABLED LOAD CELLRRI-C | 100 TONNE TO 200 TONNE

Technical SpecificationModel RRI-T300 RRI-T400 RRI-T500

Capacity 300 tonne 400 tonne 500 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 1.0% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" AlkalineCell Battery Life Alkaline "AA" continuous use: Minimum 75 Hours**Handset Display 8 digit x 8mm

Shackle Size 300 tonne 400 tonne 500 tonneCell Weight 160 kg 215 kg 235 kg

*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Model A B C D E ØGRRI-C300 600 450 1050 160 25 180RRI-C400 630 470 1120 190 25 190RRI-C500 680 500 1180 190 25 210

All measurements are in mm

Image for illustration purposes only

STANDARD FEATURES On/Off Tare Zero Peak hold Low battery indicator Battery level indicator 3 x "AA" Alkaline battery Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case 10m cable length from cell to handset

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode Rechargeable lithium batteries in handset for extended life Auto turn off after 5 minutes non use Backlit display

Page 10: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

10

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

STANDARD FEATURES On/Off Tare Zero Peak hold Range 100m Battery level indicator Frequency 433MHz Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case Load cell battery lasts 6 months on standby Remote turn off on load cell Up to 99 ID address codes Replaceable batteries in display and cell

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode AA Lithium batteries in handset for extended life Cell supplied for use with rechargeable Lithium-Ion battery pack and charger Auto turn off on display Backlit display

Technical SpecificationModel RRI-T5 RRI-T12.5 RRI-T25 RRI-T50

Capacity 5 tonne 12.5 tonne 25 tonne 50 tonneResolution 1 kg 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" Alkaline

Cell Battery LifeAlkaline "AA" continuous use: Minimum 75 Hours**

ORRechargeable continuous use: 1 week**

Handset Display 8 digit x 8mmShackle Size 6.5 tonne 13.5 tonne 25 tonne 55 tonne Cell Weight 2.5 kg 4.5 kg 6.5 kg 13.0 kg

Cell with Case 6.5 kg 8.5 kg 10.5 kg 19.0 kg*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Model A B C D E F ØGRRI-T5 225 125 290 60 25 32 27.5

RRI-T12.5 245 135 345 60 25 50 45RRI-T25 260 155 390 60 25 60 55RRI-T50 300 185 480 75 25 75 75

All measurements are in mm

Image for illustration purposes only

Drawing represents 25 tonne model

TELEMETRY LOAD CELLRRI-T | 5 TONNE TO 50 TONNE

Page 11: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

11

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

TELEMETRY LOAD CELLRRI-T | 5 TONNE TO 50 TONNE

TELEMETRY LOAD CELL RRI-T | 100 TONNE TO 200 TONNE

Technical SpecificationModel RRI-T100 RRI-T150 RRI-T200

Capacity 100 tonne 150 tonne 200 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 1.0% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" Alkaline

Cell Battery LifeAlkaline "AA" continuous use: Minimum 75 Hours**

ORRechargeable continuous use: 1 week**

Handset Display 8 digit x 8mmShackle Size 120 tonne 150 tonne 200 tonneCell Weight 50 kg 75 kg 95 kg

*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Model A B C D E ØGRRI-T100 450 300 700 120 25 100RRI-T150 520 325 820 135 25 120RRI-T200 540 350 890 150 25 145

All measurements are in mm

STANDARD FEATURES On/Off Tare Zero Peak hold Range 100m Battery level indicator Frequency 433MHz Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case Load cell battery lasts 6 months on standby Remote turn off on load cell Up to 99 ID address codes Replaceable batteries in display and cell

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode AA Lithium batteries in handset for extended life Cell supplied for use with rechargeable Lithium-Ion battery pack and charger Auto turn off on display Backlit display

Image for illustration purposes only

Page 12: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

12

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

TELEMETRY LOAD CELL RRI-T | 300 TONNE TO 500 TONNE

Technical SpecificationModel RRI-T300 RRI-T400 RRI-T500

Capacity 300 tonne 400 tonne 500 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 1.0% of FSD*

Temp Range -10 °C to +40°CHandset Dimensions 200mm x 95mm x 30mm (270g)

Handset Battery 3 x "AA" Alkaline

Cell Battery LifeAlkaline "AA" continuous use: Minimum 75 Hours**

ORRechargeable continuous use: 1 week**

Handset Display 8 digit x 8mmShackle Size 300 tonne 400 tonne 500 tonneCell Weight 160 kg 215 kg 235 kg

*Based on a BS1610 Grade 1 Calibration Machine**Depending on charge and conditionsInformation subject to change without notice

Model A B C D E ØGRRI-T300 600 450 1050 160 25 180RRI-T400 630 470 1120 190 25 190RRI-T500 680 500 1180 190 25 210

All measurements are in mm

STANDARD FEATURES On/Off Tare Zero Peak hold Range 100m Battery level indicator Frequency 433MHz Eight digit display Select units in lbs, kg, tonne or US Tons Rubber cover with lanyard Robust carry case Load cell battery lasts 6 months on standby Remote turn off on load cell Up to 99 ID address codes Replaceable batteries in display and cell

OPTIONAL FEATURES RS232C output for printer or data logging with Pipeline® software to PC or print mode AA Lithium batteries in handset for extended life Cell supplied for use with rechargeable Lithium-Ion battery pack and charger Auto turn off on display Backlit display

Image for illustration purposes only

Page 13: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

13

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

The Red Rooster range of ATEX / IECEx wireless load cells have been developed to meet the requirements of our customers in hazardous industries where explosive gases or dusts may be present, such as the offshore industry, engineering and chemical industries, or wherever accurate measurement is required in a hazardous area.

Working with Sira Certification we have developed a range of load cells from 5 to 500 Tonne with ATEX and IECEx certification for use in Zones 1 & 2. The testing and audits were in accordance with Directive 2014/34/EU and the IECEx Scheme rules for equipment with Intrinsic Safety protection. With ATEX certification being accepted throughout Europe and the IECEx certification is accepted in most other parts of the world, the range of wireless load cells can be used for force measurement, load monitoring and weighing across the world.

MARKINGSATEX - Ex II 2 GD IECEx - Ex ib IIC T4 Gb Ex ib IIIC T135°C Db

ZONESGas Zones 1 & 2 Dust Zones 21 & 22

The RRI-T-ATEX load cells are manufactured from a high strength low weight Duralloy with a factor of safety of 7:1 on the smaller cells and 5:1 on the larger cells with all being proof loaded to 150% of the rated capacity.

Our Wireless Load Cells come fully certified for use in hazardous areas, are environmentally sealed, come with advanced technology and are easy to operate. See the product data sheet for a full specification.

The handset is easily operated with one hand with a tactile switch membrane and is sealed to IP67. The easily accessible battery compartments in the hand set and the load link allows the Energiser L91 Lithium ‘AA’ batteries to be easily changed in a safe area.

ATEX / IECEx WIRELESS LOAD CELLRRI-T-ATEX

Page 14: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

14

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Technical SpecificationModel RRI-T5-ATEX RRI-T12.5-ATEX RRI-T25-ATEX RRI-T50-ATEX

Capacity 5 tonne 12.5 tonne 25 tonne 50 tonneResolution 1 kg 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Temp Range -20 °C to +40°CIP Rating IP67

Handset Dimensions 152mm x 90mm x 34mm (270g)Handset Display 8 digit x 9mmHandset Battery Use Only 2 x Energizer L91 "AA" Batteries

Wireless Load Cell Use Only 2 x Energizer L91 “AA” Batteries

Battery LifeLithium "AA"

12 x 5 min sessions per day: 2 MonthsContinuous use: 54 Hours

Shackle Size 6.5 tonne 13.5 tonne 25 tonne 55 tonneCell Weight 2.5 kg 4.5 kg 6.5 kg 13.0 kg

Cell with Case 6.5 kg 8.5 kg 10.5 kg 19.0 kg*Based on a BS1610 Grade 1 Calibration MachineOnly replace batteries in a safe areaInformation subject to change without notice

ATEX / IECEx WIRELESS LOAD CELL RRI-T-ATEX | 5 TONNE - 50 TONNE

Image for illustration purposes only

GAS ZONES 1 + 2DUST ZONES 21 + 22

STANDARD FEATURES Tare Zero & peak hold High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy Frequency 2.4 GHz Robust carry case Long battery life with battery level indicator Turn off on load cell or remotely from handset Replaceable batteries in display and cell High factor of safety

PARTS LISTDESCRIPTIONPART NUMBERQTYITEM

Front Panel (for RRI−T)DRG 1483−0311Rear Panel (for RRI−AA)DRG 1483−0612

Battery CoverDRG 1483−0713’O’ ring72 x 2 NBR 7014’O’ ring132 355 NBR7D25

Hexagon socket head shoulder screws (M5x16)ISO 7379 − 6 x 1046Hexagon socket head shoulder screws (M5x12)ISO 7379 − 6 x 12127

Threaded Insert M5RS−664−735548Countersunk ScrewISO 2009 − M3 x 1029

On/Off SwitchIPR1 SAD2110BodyDRG 1491−01 (5T) or DRG 1487−01 (12,5T) or

DRG 1483−01 (25T) or DRG 1486−01 (50T)111

Battery Holder229−3260212Mantracourt Transmit BoardX24−SAe113

M3x8 Spacer146−6785aaa214 M2 plastic bolt215

Product LabelDRG 1491−02116

Title of Project

B. Aitken

Approved By

Checked By

Drawn By

Designed By

B. Aitken

T. Mikolajewski

T. Mikolajewski

1:2Scale

Surname

Surface Roughness

Angular � 0,5°

Linear

If In Doubt Ask

1 / 1

N/A

Weight

3

Title of Part

Wireless Load Cell ATEX / IECEx Certification

Date

Material

Sheet Size

A4

RRI−T5−ATX, RRI−T12,5−ATX, RRI−T25−ATX, RRI−T50−ATX

Date

Revision

Profile Number

Replaces Drawing

14/07/2017

Signature

Part Number

DRG 1491−00 (ATEX)

up to 5 � 0,05over 5 up to 30 � 0,1

over 30 up to 120 � 0,2over 120 up to 500� 0,25over 500 up to 1000 � 0,5

over 1000 � 1

N10

Tolerancesall dimensions are in milimeters

unless otherwise specified07/11/2012

14/07/2017

REVISION HISTORYREV. DATE APPROVED

3

DB

C A

F

F

E

6312 94 8

5 211

13

10 177

14 15 5

12

Material Type:Alloy EN AW−7075−T651

Total of Magnesium,Titanium and Zirconium

is less than 7,5%

Note: A layer of silicone greasemay be applied to the jointingsurfaces where O−rings are fitted

Note:Only baseefa certifiedAA cells can be used

Notes: 1. TIVAR 1000 EC or ASTL to be used in the manufactureof DRG 1483−03, DRG 1483−06 and DRG 1483−07 2. Between the label item 16 and the transmit board item 13 there isa distance of 17mm. Made up of 11mm wall thickness for item 1 and 6 mm for the spacers item 14

16

MODEL A B C D E F

RRI−T5−ATX 225 125 290 32 74 Ø27,5

RRI−T12,5−ATX 245 135 345 50 74 Ø45

RRI−T25−ATX 260 155 390 60 74 Ø55

RRI−T50−ATX 300 185 480 75 89 Ø75

Model A B C D E FØ

RRI-T5-ATEX 225 125 290 32 74 27.5RRI-T12.5-ATEX 245 135 345 50 74 45RRI-T25-ATEX 260 155 390 60 74 55RRI-T50-ATEX 300 185 480 75 89 75

II 2 GD Ex ib IIC T4 GbEx ib IIIC T135�C Db

Page 15: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

15

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Technical SpecificationModel RRI-T100-ATEX RRI-T150-ATEX RRI-T200-ATEX

Capacity 100 tonne 150 tonne 200 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Temp Range -20 °C to +40°CIP Rating IP67

Handset Dimensions 152mm x 90mm x 34mm (270g)Handset Display 8 digit x 9mmHandset Battery Use Only 2 x Energizer L91 "AA" Batteries

Wireless Load Cell Use Only 2 x Energizer L91 “AA” Batteries

Battery LifeLithium "AA"

12 x 5 min sessions per day: 2 MonthsContinuous use: 54 Hours

Shackle Size 120 tonne 150 tonne 200 tonneCell Weight 50 kg 75 kg 95 kg

*Based on a BS1610 Grade 1 Calibration MachineOnly replace batteries in a safe areaInformation subject to change without notice

Image for illustration purposes only

GAS ZONES 1 + 2DUST ZONES 21 + 22

STANDARD FEATURES Tare Zero & peak hold High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy Frequency 2.4 GHz Robust carry case Long battery life with battery level indicator Turn off on load cell or remotely from handset Replaceable batteries in display and cell High factor of safety

PARTS LISTDESCRIPTIONPART NUMBERQTYITEMBattery CoverDRG 1483−0711

’O’ ring72 x 2 NBR 7012’O’ ring240 x 3 NBR 7023

Hexagon socket head shoulder screws (M5x16)ISO 7379 − 6 x 1044Hexagon socket head shoulder screws (M5x12)ISO 7379 − 6 x 12165

Threaded Insert M5RS−664−735546Countersunk ScrewISO 2009 − M3 x 827

On/Off SwitchIPR1 SAD218Battery Holder229−326029

Mantracourt Transmit BoardX24−SAe110M3x8 Spacer146−6785aaa211

M2 plastic bolt212Product LabelDRG 1491−02113

BodyDRG 1490−01 (100T) or DRG 1509−01 (150T) or DRG 1510−01 (200T) or DRG 1498−01 (300T) or DRG 1511−01 (400T) or DRG 1508−01 (500T)

114

Rear Panel (for RRI−AA)DRG 1508−07115Front Panel (for RRI−T)DRG 1508−03116

Title of Project

Approved By

Checked By

Drawn By

Designed By

B. Aitken

T. Mikolajewski

T. Mikolajewski

Not toScale

Scale

Surname

Surface Roughness

Angular � 0,5°

Linear

If In Doubt Ask

1 / 1

N/AWeight

0

Title of Part

Wireless Load Cell ATEX / IECEx Certification

Date

Material

Sheet Size

A3

RRI−T100−ATX, RRI−T150−ATX, RRI−T200−ATX,RRI−T300−ATX, RRI−T400−ATX, RRI−T500−ATX

Date

Revision

Profile Number

Replaces Drawing

21/12/2017

Signature

Part Number

DRG 1490−00 (ATEX)

up to 5 � 0,05over 5 up to 30 � 0,1

over 30 up to 120 � 0,2over 120 up to 500� 0,25over 500 up to 1000 � 0,5

over 1000 � 1

N10

Tolerancesall dimensions are in milimeters

unless otherwise specified21/12/2017

21/12/2017

REVISION HISTORYREV. DATE APPROVED

0

B

C A

F

F

D

E

MODEL A B C D E FRRI−T100−ATX 450 300 700 120 135 Ø100RRI−T150−ATX 520 325 820 135 150 Ø120RRI−T200−ATX 540 350 890 150 165 Ø145RRI−T300−ATX 600 450 1050 160 175 Ø180RRI−T400−ATX 630 470 1120 190 205 Ø190RRI−T500−ATX 680 500 1180 190 205 Ø210

Material Type:Alloy EN AW−7075−T651Total of Magnesium,Titanium and Zirconiumis less than 7,5%

Notes: 1. TIVAR 1000 EC or ASTL to be used in the manufactureof DRG 1508−03, DRG 1508−07 and DRG 1483−07 2. Between the label item 13 and the transmit board item 10 there isa distance of 22mm. Made up of 16mm wall thickness for item 16 and 6 mm for the spacers item 11

Note: A layer of silicone greasemay be applied to the jointingsurfaces where O−rings are fitted

Note:Only baseefa certifiedAA cells can be used

41

7

9

6

5

2

15314

3

12

11

16 513

10

8

Model A B C D E FØ

RRI-T100-ATEX 450 300 700 120 135 100RRI-T150-ATEX 520 325 820 135 150 120RRI-T200-ATEX 540 350 890 150 165 145

II 2 GD Ex ib IIC T4 GbEx ib IIIC T135�C Db

ATEX / IECEx WIRELESS LOAD CELL RRI-T-ATEX | 100 TONNE - 200 TONNE

Page 16: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

16

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Technical SpecificationModel RRI-T300-ATEX RRI-T400-ATEX RRI-T500-ATEX

Capacity 300 tonne 400 tonne 500 tonneResolution 1 kg 1 kg 1 kgAccuracy < +/- 0.5% of FSD*

Temp Range -20 °C to +40°CIP Rating IP67

Handset Dimensions 152mm x 90mm x 34mm (270g)Handset Display 8 digit x 9mmHandset Battery Use Only 2 x Energizer L91 "AA" Batteries

Wireless Load Cell Use Only 2 x Energizer L91 “AA” Batteries

Battery LifeLithium "AA"

12 x 5 min sessions per day: 2 MonthsContinuous use: 54 Hours

Shackle Size 300 tonne 400 tonne 500 tonneCell Weight 160 kg 215 kg 235 kg

*Based on a BS1610 Grade 1 Calibration MachineOnly replace batteries in a safe areaInformation subject to change without notice

Image for illustration purposes only

GAS ZONES 1 + 2DUST ZONES 21 + 22

STANDARD FEATURES Tare Zero & peak hold High resolution 5 Tonne to 500 Tonne Range 500m Lightweight high strength aluminium alloy Frequency 2.4 GHz Robust carry case Long battery life with battery level indicator Turn off on load cell or remotely from handset Replaceable batteries in display and cell High factor of safety

Model A B C D E FØ

RRI-T300-ATEX 600 450 1050 160 175 180RRI-T400-ATEX 630 470 1120 190 205 190RRI-T500-ATEX 680 500 1180 190 205 210

II 2 GD Ex ib IIC T4 GbEx ib IIIC T135�C Db

PARTS LISTDESCRIPTIONPART NUMBERQTYITEMBattery CoverDRG 1483−0711

’O’ ring72 x 2 NBR 7012’O’ ring240 x 3 NBR 7023

Hexagon socket head shoulder screws (M5x16)ISO 7379 − 6 x 1044Hexagon socket head shoulder screws (M5x12)ISO 7379 − 6 x 12165

Threaded Insert M5RS−664−735546Countersunk ScrewISO 2009 − M3 x 827

On/Off SwitchIPR1 SAD218Battery Holder229−326029

Mantracourt Transmit BoardX24−SAe110M3x8 Spacer146−6785aaa211

M2 plastic bolt212Product LabelDRG 1491−02113

BodyDRG 1490−01 (100T) or DRG 1509−01 (150T) or DRG 1510−01 (200T) or DRG 1498−01 (300T) or DRG 1511−01 (400T) or DRG 1508−01 (500T)

114

Rear Panel (for RRI−AA)DRG 1508−07115Front Panel (for RRI−T)DRG 1508−03116

Title of Project

Approved By

Checked By

Drawn By

Designed By

B. Aitken

T. Mikolajewski

T. Mikolajewski

Not toScale

Scale

Surname

Surface Roughness

Angular � 0,5°

Linear

If In Doubt Ask

1 / 1

N/AWeight

0

Title of Part

Wireless Load Cell ATEX / IECEx Certification

Date

Material

Sheet Size

A3

RRI−T100−ATX, RRI−T150−ATX, RRI−T200−ATX,RRI−T300−ATX, RRI−T400−ATX, RRI−T500−ATX

Date

Revision

Profile Number

Replaces Drawing

21/12/2017

Signature

Part Number

DRG 1490−00 (ATEX)

up to 5 � 0,05over 5 up to 30 � 0,1

over 30 up to 120 � 0,2over 120 up to 500� 0,25over 500 up to 1000 � 0,5

over 1000 � 1

N10

Tolerancesall dimensions are in milimeters

unless otherwise specified21/12/2017

21/12/2017

REVISION HISTORYREV. DATE APPROVED

0

B

C A

F

F

D

E

MODEL A B C D E FRRI−T100−ATX 450 300 700 120 135 Ø100RRI−T150−ATX 520 325 820 135 150 Ø120RRI−T200−ATX 540 350 890 150 165 Ø145RRI−T300−ATX 600 450 1050 160 175 Ø180RRI−T400−ATX 630 470 1120 190 205 Ø190RRI−T500−ATX 680 500 1180 190 205 Ø210

Material Type:Alloy EN AW−7075−T651Total of Magnesium,Titanium and Zirconiumis less than 7,5%

Notes: 1. TIVAR 1000 EC or ASTL to be used in the manufactureof DRG 1508−03, DRG 1508−07 and DRG 1483−07 2. Between the label item 13 and the transmit board item 10 there isa distance of 22mm. Made up of 16mm wall thickness for item 16 and 6 mm for the spacers item 11

Note: A layer of silicone greasemay be applied to the jointingsurfaces where O−rings are fitted

Note:Only baseefa certifiedAA cells can be used

41

7

9

6

5

2

15314

3

12

11

16 513

10

8

ATEX / IECEx WIRELESS LOAD CELL RRI-T-ATEX | 300 TONNE - 500 TONNE

Page 17: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

17

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

RR-SC / RR-ST SERIES

Produced in capacities from 25 tonne to 500 tonne. The shackle body is manufactured from galvanised alloy steel. The shackle pin (nickel steel up to 35 tonne, alloy steel on larger capacities) is retained in the shackle body by means of a nut and split pin, and an anti-rotation device is incorporated in the pin to ensure correct alignment. The pin itself is through bored and strain gauges are internally resin bonded at both shear planes. A close fitting tapered steel bobbin is included to ensure that the load is applied through the midline of the shackle pin. Load cell shackles are available in both cabled (RR-SC) and radio telemetry (RR-ST) versions. Up to 50 tonne capacity accuracy is better than 0.5% F.S.D. over 50 tonne accuracy is better that 1.0% F.S.D.

RR-SM SERIES

Produced in capacities from 50 tonne to 500 tonne. The shackle body is manufactured of galvanised alloy steel. The shackle pin is made from stainless steel and is retained in the shackle body by means of a nut and split pin. An anti-rotation device is incorporated in the pin to ensure correct alignment. The pin itself is through bored and strain gauges are internally resin bonded at both shear planes. A close fitting tapered steel bobbin is included to ensure that the load is applied through the midline of the shackle pin. Our range of marine load cell shackles are proof tested to 200% of the shackle WLL and come with a 5:1 factor of safety. Operational temperature range -20ºC to +80ºC.

LOAD SHACKLESRR-SC | RR-ST | RR-SM

Page 18: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

18

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Technical SpecificationCabled Telemetry Capacity A B C D E F H Weight

RR-SC25 RR-ST25 25 tonne 50 120 182 111 83 85 320 ~25 kgRR-SC50 RR-ST50 50 tonne 66 140 255 177 105 95 405 ~41 kgRR-SC70 RR-ST70 70 Tonne 72 140 310 190 127 110 426 ~65 kgRR-SC85 RR-ST85 85 tonne 73 140 335 195 128 110 540 ~70 kg

RR-SC100 RR-ST100 100 tonne 94 140 373 239 150 118 540 ~90 kgRR-SC150 RR-ST150 150 tonne 100 140 380 265 165 150 620 ~194 kgRR-SC175 RR-ST175 175 tonne 113 140 485 290 175 186 620 ~265 kgRR-SC250 RR-ST250 250 tonne 115 140 495 305 200 200 675 ~450 kgRR-SC300 RR-ST300 300 tonne 120 140 600 305 200 220 790 ~842 kg

Temp Range -10°C to +40°CAll measurements are in mmInformation subject to change without notice

Image for illustration purposes only

DRG 1468-00_2 (for Catalog)

0

Part number

Revision number

Replaces draw

N/A

Material

2015-01-08

Title of part

Scale

Surn

ame

Sign

atur

e

Date Weight

L. KolkoDesigned by

Checked by

Title of project

Approved by

Dat

e

VAULT REVISION HISTORYREV DATE APPROVED

0

H

D

B

C

A E A

F

Optional Transit Frame

STANDARD FEATURES Strain gauges fitted within the bore of the shackle pin for max protection Bow or ‘D’ type shackle to US Federal specification RR-C-271 and European standard EN 13889 IP68 protection Robust waterproof plugs and sockets Interface to Ikon-mtx or Ikon-cabled display Mains battery charger for shackle Handheld display powered by 3 x “AA” batteries 8 digit x 8mm display Robust carry case for display unit Rechargeable battery in telemetry load shackle

LOAD SHACKLERR-SC CABLED | RR-ST TELEMETRY

Page 19: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

19

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

LOAD SHACKLERR-SC CABLED | RR-ST TELEMETRY

DimensionsModel Capacity A B C D L

RR-SM50 50 tonne 253 53 122 57 197RR-SM75 75 tonne 327 69 145 70 267RR-SM100 100 tonne 365 79 165 82.5 330RR-SM150 150 tonne 468 104 229 108 368RR-SM200 200 tonne 533 114 267 121 397RR-SM300 300 tonne 635 127 305 152 495RR-SM400 400 tonne 660 152 356 178 572RR-SM500 500 tonne 711 191 381 191 645

All measurements are in mmInformation subject to change without notice

STANDARD FEATURES Strain gauges fitted within the bore of the shackle pin for maximum protection Bow or ‘D’ type shackle to US Federal specification RR-C-271 and European standard EN 13889 Shackle pin sealed to IP68 protection Robust nylon reinforced plugs and sockets with locked rings Interface to RRI-C display Handset powered by 3 x "AA" batteries Robust carry case for display unit

Image for illustration purposes only

DRG 1600-00_Symb

0

Part number

Revision number

Replaces draw

N/A

Material

2014-09-19

Title of part

Scale

Surn

ame

Sign

atur

e

Date Weight

L. KolkoDesigned by

Checked by

Title of project

Approved by

Dat

e

VAULT REVISION HISTORYREV DATE APPROVED0

B

A

L

D

C

B

C

A

D

L

DRG 1600-00_Symb

0

Part number

Revision number

Replaces draw

N/A

Material

2014-09-19

Title of part

Scale

Surn

ame

Sign

atur

e

Date Weight

L. KolkoDesigned by

Checked by

Title of project

Approved by

Dat

e

VAULT REVISION HISTORYREV DATE APPROVED0

B

A

L

D

C

B

C

A

D

L

Optional Transit Frame

MARINE LOAD SHACKLERR-SM

Page 20: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

20

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

RR-COM750

Manufactured in a range of capacities from 0.5 tonne to 20 tonne from high strength stainless steel with an integrated load button. High quality gauges are used throughout the range to deliver a high accuracy. High standard IP protection against water and dust ingress to IP68. Supplied as standard with an individual hand held display per load cell, or can be supplied as a system with multiple cells configured to one display.

RR-COM5500

Manufactured in a range of capacities from 0.5 kN to 50 kN from high strength aluminium. Can be wired for tension or compression. High quality gauges are used throughout the range to deliver a high accuracy. High standard IP protection against water and dust ingress to IP66. Supplied as standard with an individual hand held display per load cell, or can be supplied as a system with multiple cells configured to one display. Various fittings can be screwed into the M12/M20 threaded holes, such as eye bolts, clevises and rods.

RR-COM9500

Manufactured in a range of capacities from 25 tonne to 1500 tonne from high strength stainless steel. High quality gauges are used throughout the range to deliver a high accuracy. High standard IP protection against water and dust ingress to IP68. Supplied as standard with an individual hand held display per load cell, or can be supplied as a system with multiple cells configured to one display.

COMPRESSION CELLSRR-COM

COMPRESSION LOAD CELLRR-COM5500

Page 21: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

21

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

COMPRESSION CELLSRR-COM

Image for illustration purposes only

Technical SpecificationStandard Load Ranges kN 0.5, 1, 2.5, 5, 10, 20, 50

Safe Service Load % 150Ultimate Load % 300

Input Resistance Ω 380 +/- 30Output Resistance Ω 350 +/- 2

Creep after 30 mins (20°C) % < +/- 0.05%Operational Temp Range °C -20 to +70Environmental Protection IP66

Cable Length Standard Metres 3Insulation G Ω >2 at 100V.dc

Electrical Connections6 Core Cable, Wired in Compression Mode

Red + InputBlue - Input

Yellow - OutputGreen + Output

Black/White Preset Cal RefNote: All percentages related to Full Rated Load

Capacity A B C D0 - 0.5, 1, 2.5, 5kN 70.0 25.0 75.0 M12

0 - 10. 20kN 75.0 30.0 100.0 M200 - 50kN 100.0 30.0 120.0 M20

All measurements are in mmInformation subject to change without notice

COMPRESSION LOAD CELLRR-COM5500

Page 22: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

22

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

Image for illustration purposes only

Technical SpecificationStandard Load Ranges tonne 0.5, 1, 2, 5, 10, 20

Safe Service Load % 150Ultimate Load % 300

Input Resistance Ω 750 +/- 20Output Resistance Ω 700 +/- 5

Operational Temp Range °C -20 to +70Environmental Protection IP68

Construction Stainless SteelInsulation G Ω >2 at 100V.dc

Electrical Connections6 Core Cable, Wired in Compression Mode

Red + InputBlue - Input

Yellow - OutputGreen + Output

Note: All percentages related to Full Rated Load

Capacity (tonne) B ØD H P R T ØW0.5, 1 4 59 21 42 50 M3 x 7 10

2, 5, 10, 20 5 98 35 72 150 M6 x 18 20All measurements are in mmInformation subject to change without notice

Low Profile Comp Cell TNC 750 (for Catalog)

0

Part number

Revision number

Replaces draw

Material

2015-01-08

Title of part

Scale

Surn

ame

Sign

atur

e

Date Weight

L. KolkoDesigned by

Checked by

Low Profile Comp Cell TNC 750Title of project

Approved by

Dat

e

VAULT REVISION HISTORYREV DATE APPROVED

0

H

ØW

Radi

us R

B

ØD

Threaded holes Ton PCD P

COMPRESSION LOAD CELLRR-COM750

COMPRESSION LOAD CELLRR-COM9500

Page 23: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

23

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

COMPRESSION LOAD CELLRR-COM750

Cell Type Capacity ØA ØB ØC ØD E F G Comp 25 25 tonne 75 60 75 125 15 100 30

Comp 50-100 100 tonne 100 80 100 150 20 150 50Comp 200 200 tonne 127 110 127 150 30 180 50Comp 300 300 tonne 150 130 150 200 30 180 50Comp 400 400 tonne 150 136 150 200 38 180 50Comp 500 500 tonne 203 170.5 203 265 50 300 50

Comp 1000 1000 tonne 290 250 290 335 50 425 75Comp 1500 1500 tonne 350 300 350 400 75 490 100

All measurements are in mmInformation subject to change without notice

Technical SpecificationStandard Load Ranges tonne 25, 50, 100, 200, 300, 400, 500, 1000, 1500

Safe Service Load % 150Ultimate Load % 500

Safe Side Load % 100Input Resistance Ω 700 (500-1500te 1400Ω)

Output Resistance Ω 700 +/- 2Creep after 30 mins (20°C) % < +/- 0.05%Operational Temp Range °C -20 to +80Environmental Protection IP68

Cable Length Standard Metres 10Insulation G Ω >2 at 100V.dc

Electrical ConnectionsIP68 6 Way Amphenol Connector

Pin A + InputPin E + OutputPin C - InputPin F - Output

Note: All percentages related to Full Rated Load Image for illustration purposes only

COMPRESSION LOAD CELLRR-COM9500

Page 24: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

24

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

RLM

Produced to accept cable diameters from 13mm to 88mm, the Red Rooster RLM system electronically monitors the load on a running line (winch, crane, etc.) and is displayed digitally. It can optionally monitor the length of the line out and speed (including direction) in any engineering units. It’s modular design enables facilities to be added or removed as requirements change.

RUNNING LINE MONITORRLM

Page 25: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

25

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

RUNNING LINE MONITORRLM

DRG 1442-00 (for Catalog)

0

Part number

Revision number

Replaces draw

118,38 kg

Material

2015-01-08

Running Line Monitor - Ø52 rope - G.A.Title of part

Scale

Surn

ame

Sign

atur

e

Date Weight

L. KolkoDesigned by

Checked by

Running Line Monitor Ø52 ropeTitle of project

Approved by

Dat

e

VAULT REVISION HISTORYREV DATE APPROVED

0

A

B

CD

J

E

F

G

H

K

L

Technical SpecificationModel A B C D E F G H J K LRLM13 980 800 180 30 98 128 192 220 320 218 320RLM20 980 800 180 30 98 128 192 220 320 218 320RLM35 980 800 180 42 98 128 192 220 320 218 320

RLM50 980 800 180 To Suit 98 128 192 220 320 218 320

RLM88 1446 1118 230 To Suit 101 133 196 222 395 410 395

All measurements are in mmInformation subject to change without notice

Model Suit Wire Rope Diameter Maximum CapacityRLM13 13mm - 19mm 5 tonneRLM20 16mm - 26mm 15 tonne

RLM35 28mm - 40mm 35 tonne

RLM50 42mm - 52mm 50 tonneRLM88 54mm - 88mm 150 tonne

Image for illustration purposes only

STANDARD FEATURES Five wheel construction guides wire smoothly onto the monitoring wheel Wire may be fitted without tools, using a gloved hand Load pin forms shaft of centre wheel Strain gauges mounted in shaft bore (High impact protection & IP65) Wheels mounted on roller bearings with grease nipples 10-12 hour battery life between charges Battery charger 10m extension cable

OPTIONAL FEATURES Line speed monitoring Line out monitoring Mains operation PC interfacing & data logging Paperless chart recorder RS232 output

RUNNING LINE MONITORRLM

Page 26: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

26

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

CRANE SCALE

Manufactured in a range of capabilities from 200 kgs to 85 tonnes. The TEO crane scale uses proven technology (hydrostatic, bourdon tube) and incorporates it in to a simple, functional and reliable weighing device.

Current health and safety legislation requires companies to have knowledge of the loads being handled regardless of the industry. In the TEO crane scale we have an inexpensive load-measuring device which can be hung up, used and then stored until the next time it is required, secure in the knowledge that it will continue to perform reliably.

CRANE SCALESK

Page 27: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

27

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

STANDARD FEATURES Accuracy better than display resolution (1% of rated load, nominal) 100% taring capability (by rotating the dial device) Zero set by rotating the dial face Plexiglass dial face cover 160mm scale diameter Graduated in kilogrammes and tonnes Fixed link top suspension up to 5000 kgs Hook with latch bottom suspension up to 5000 kgs

OPTIONAL FEATURES Display graduated in pounds (lbs) or tonnes Display remote from the load cell (hydrostatic tube connection)

Image for illustration purposes only

Type Capacity (kgs)

Dial Increms

Weight (kgs) A mm B mm C mm D mm E mm

200-SK1 200 1 kg 5 60 53 230 27 35320-SK2 320 2 kg 5 60 53 230 27 35500-SK2 500 2 kg 5 60 53 230 27 35750-SK5 750 5 kg 5 60 53 230 27 351250-SK5 1250 5 kg 5 60 53 230 27 352000-SK10 2000 10 kg 5 60 53 230 27 353200-SK20 3200 20 kg 5.5 75 53 280 34 465000-SK20 5000 20 kg 6.5 75 53 300 42 567500-SK20 7500 50 kg 8.1 40 41 213 - -

12500-SK50 12500 50 kg 8.1 42 30 21525000-SK100 25000 100 kg 12.9 55 42 26250000-SK200 50000 200 kg 30 75 50 33585000-SK500 85000 500 kg 60 85 60 390

Information subject to change without notice

CRANE SCALESK

CRANE SCALESK

Page 28: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

28

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

REPAIR AND CALIBRATION

LOAD CELL REPAIR

Our team of electronic technicians have a vast knowledge of manufacturing Red Rooster load measuring equipment and the repair of other manufacturer's equipment. From standard units to the most complex weighing systems we can trace the defective component before repair and calibration.

CALIBRATION

We can calibrate up to 400 tonne in tension and up to 100 tonne in compression using our in-house calibration machines.

All our calibration equipment is checked annually and is calibrated in accordance with BS 7500-1:2004.

CERTIFICATION

Along with the calibration certificate you will also get a 'Certificate of Thorough Examination' as a load cell is seen as a piece of lifting gear by LEEA.

OTHER PRODUCTS

Page 29: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

29

RED ROOSTER LIFTING T: +44 (0) 1651 872101Nauta House, The Meadows E: [email protected], Aberdeenshire W: www.redroosterlifting.comUnited Kingdom, AB51 0EZ PC-LC1 REV0

WINCHES INDUSTRIAL HAND WINCHES JIB CRANES OVERHEAD CRANES ELECTRIC HOISTS MANUAL HOISTS LEVER HOISTS AIR HOISTS LOW HEADROOM AIR HOISTS ATEX AIR HOISTS RACK & PINION AIR TROLLEYS

OTHER PRODUCTS

Page 30: LOAD CELL PRODUCTS CATALOGUE - Amazon S3€¦ · CABLED LOAD CELL RRI-C | 100 TONNE TO 200 TONNE. 9 RED ROOSTER LIFTING T: +44 (0) 1651 872101 Nauta House, The Meadows E: sales@redroosterlifting.com

HEAD OFFICENauta House, The Meadows T: +44 (0) 1651 872101Oldmeldrum, Aberdeenshire E: [email protected] Kingdom, AB51 0EZ W: www.redroosterlifting.com

DEPOTUnit 26 Kelvin way Trading Estate T: +44 (0) 121 525 4162Kelvin Way, West Bromwich E: [email protected] Midlands, B70 7TW