Page 1
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
1 / 16
LM-79-08 Test Report
For
Revolution Lighting Technologies, Inc.
(Brand Name: Revolution Lighting Technologies)
2280 Ward Ave. Simi Valley CA. 93065
Model name(s):
203012-21X-XXX[-A, -USA or Blank] Report Type: Testing and Report According to IES LM-79-2008
Type of
Luminaire: Internal Driver/Line Voltage (UL Type B) Lamps
Report Date: 2019-01-30
Prepared By:
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base,
No. 66 Qingyi Road, Ningbo National Hi-Tech Zone,
Ningbo, Zhejiang
Test & Report By: Review By:
Xeon Ren Johnson Sun
Engineer: Xeon Ren Manager: Johnson Sun
Note: 1. The results contained in this report pertain only to the tested samples
2. This report does not imply product certification, approval, or endorsement by NVLAP, NIST,
or any agency of the Federal Government.
Page 2
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
2 / 16
1.1 Product Information:
Model Number 203012-21X-XXX[-A, -USA or Blank]
Remark
Where “X” stand for CCT, 1=3000k, 2=3500k,
3=4000k, 5=5000k
Where the “XXX” can be “A”, “USA”, or blank,
and represents manufacturing origin.
“A” = Trade Agreements Act (TAA) - Compliant
“USA” = Buy American Act (BAA) - Compliant
Blank = Non-USA Manufacturing.
Representative (Tested) Model 203012-211-XXX
203012-215-XXX
Model Difference All construction and rating are the same, except
CCT and manufacturing origin.
SKU (if available) N/A
Type of Luminaire
(for integral lamps, list base type and lamp type) Internal Driver/Line Voltage (UL Type B) Lamps
LED Manufacturer EVERLIGHT ELECTRONICS CO., LTD
LED Model 3000K: 67-21S/KK4C-H302932Z6/2T(HN)
5000K: 67-21S/KK4C-H503132Z6/2T(HN)
Dimming Non-dimmable
Sample Number JBE190106-I1,I2(3000K),I3(5000K)
Date of Receipt Jan.20,2019
Luminaire Aperture (for downlights) -- in.
Luminaire Length 900 mm
Luminaires Width -- mm
Number of Units (modular products) N/A s
1.2 Rated Values:
Rated Voltage / Frequency 120-277Vac, 50/60Hz
Nominal Power 12W
Rated Initial Lamp Lumen --
Declared CCT 3000K,3500K,4000K,5000K
Page 3
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
3 / 16
1.3 Test Specifications:
Test item
1. Total Luminous Flux
2. Luminous Distribution Intensity
3. Luminous Efficacy
4. Correlated Color Temperature
5. Color Rendering Index
6. Chromaticity Coordinate
7. Electrical Parameters
Reference Standard
1. IES LM-79-2008 Electrical and Photometric Measurements of
Solid-State Lighting Products
2. ANSI C78.377-2015 Specifications for the Chromaticity of Solid
State Lighting Products
3. CIE 13.3-1995 Method of Measuring and Specifying Colour
Rendering Properties of Light Sources
4. CIE 15-2004 Technical Report Colorimetry
5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
6. IESNA TM-16-05 Technical Memorandum on Light Emitting
Diode (LED) Sources and Systems
Reference Work Instruction QD25
1.4 Test Methods
1) Photometric and Light Distribution Measurement – Goniophotometer Method:
Photometric parameters were measured using the goniophotometer and software. The ambient
temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the
sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.
It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were
calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.
2) Chromaticity Measurement – Sphere-Spectroradiometer Method:
Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,
60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color
temperature and color rendering index were calculated from the spectral power distribution taken at 5
nm intervals over the range of 380 to 780 nm.
3) Electrical Measurements:
Electrical parameters were measured using power meters incorporated in goniophotometer or
sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at
25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before
measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion
were measured by and read from the power meter.
Page 4
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
4 / 16
2.1 Summary of Test Result
Criteria Item Measured Value Compliance Requirement
(DLC V4.4)
Power(W)
3000K
Bare Lamp
120V 13.05 N/A N/A
277V 13.01
3000K
In Luminaire
120V 24.99
N/A N/A 277V 24.98
5000K
Bare Lamp
120V 13.12
277V 13.10
Power Factor
3000K
Bare Lamp
120V 0.9658
Pass >= 0.9(-3%)
277V 0.9160
3000K
In Luminaire
120V 0.9554
277V 0.9123
5000K
Bare Lamp
120V 0.9604
277V 0.9087
THD %
3000K
Bare Lamp
120V 17.41
Pass <= 20(+5)
277V 21.54
3000K
In Luminaire
120V 17.82
277V 21.81
5000K
Bare Lamp
120V 17.93
277V 21.89
CRI
3000K Bare Lamp 81.6
Pass >= 80(-2) 3000K In Luminaire 82.0
5000K Bare Lamp 82.1
CCT (K)
3000K Bare Lamp 3027
Pass <=5000K 3000K In Luminaire 3031
5000K Bare Lamp 5046
Luminous Intensity
Distribution Zonal lumens in the 0-60°: 67.9 Pass >= 40(-3)
Total Luminous
3000K
Bare Lamp
120V 1501
Pass
>=1200(-10%) 277V 1507
3000K
In Luminaire
120V 2639.7 >=2200(-10%)
277V 2651.0
5000K
Bare Lamp
120V 1594 >=1200(-10%)
277V 1602
Luminous Efficacy
3000K
Bare Lamp
120V 115.02
Pass
Standard: >=
110(-3%) 277V 115.83
3000K
In Luminaire
120V 105.63 Standard: >=
100(-3%) 277V 106.12
Page 5
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
5 / 16
5000K
Bare Lamp
120V 121.49 Standard: >=
110(-3%) 277V 122.29
Page 6
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
6 / 16
2.2 Electrical, Photometric and Chromaticity Measurements
Test date 2019-01-24 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number 203012-211-XXX
Electrical Measurement for Bare-lamp:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
JBE190106-I
1
120.0 60 0.1126 13.05 0.9658 17.41
277.0 60 0.0513 13.01 0.9160 21.54
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 81 R9 2
Frequency (Hz) 60 R2 92 R10 82
CCT (K) 3027 R3 94 R11 78
Duv -0.0009 R4 78 R12 70
Chromaticity (x, y) x=0.4338 y=0.4008 R5 81 R13 84
Chromaticity (u’, v’) u'=0.2499 v'=0.5196 R6 90 R14 98
Color Rendering Index (CRI) 81.6 R7 81 R15 73
R9 2 R8 56 -- --
Photometric Measurement –Sphere-Spectroradiometer Method:
Parameter Result
Test Voltage (V) 120.0 277.0
Frequency (Hz) 60 60
Total Luminous (lm) 1501 1507
Luminous Efficacy (lm/W) 115.02 115.83
Worst Luminous/Highest Watts 115.02
Page 7
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
7 / 16
Spectral Power Distribution & Chromaticity Diagram
Page 8
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
8 / 16
2.3 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
Test date 2019-01-24 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number 203012-211-XXX
Electrical Measurement for 2-lamp in Lithonia C2 25 MVOLT GEB10IS:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
JBE190106-I
1,I2
120.0 60 0.2180 24.99 0.9554 17.82
277.0 60 0.0988 24.98 0.9123 21.81
Chromaticity Measurement - Sphere-Spectroradiometer Method for 2-lamp in
Lithonia C2 25 MVOLT GEB10IS:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 81 R9 4
Frequency (Hz) 60 R2 92 R10 83
CCT (K) 3031 R3 94 R11 78
Duv -0.0012 R4 79 R12 71
Chromaticity (x, y) x=0.4331 y=0.3999 R5 81 R13 84
Chromaticity (u’, v’) u'=0.2499 v'=0.5191 R6 91 R14 98
Color Rendering Index (CRI) 82.0 R7 81 R15 73
R9 4 R8 57 -- --
Photometric Measurement – Goniophotometer Method for 2-lamp in Lithonia
C2 25 MVOLT GEB10IS:
Parameter Result
Test Voltage (V) 120.0 277.0
Frequency (Hz) 60 60
Total Luminous (lm) 2639.7 2651.0
Luminous Efficacy (lm/W) 105.63 106.12
Worst Luminous/Highest Watts 105.63
Zonal lumens in the 0-60° zone (%) 67.9 --
Beam Angle (°) 118.8 --
Center Beam Candle Power (cd) 779 --
Page 9
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
9 / 16
Zonal Lumen Tabulation
Zonal Lumen Summary
Zone Lumens % Luminaire
0-30 604.9 22.9%
0-40 992.6 37.6%
0-60 1,791.2 67.9%
60-90 701.5 26.6%
70-100 436.8 16.5%
90-120 120.0 4.5%
0-90 2,492.7 94.4%
90-180 146.8 5.6%
0-180 2,639.5 100%
Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
0-10 73.7 2.8% 90-100 68.8 2.6%
10-20 211.1 8.0% 100-110 20.9 0.8%
20-30 320.0 12.1% 110-120 30.3 1.1%
30-40 387.7 14.7% 120-130 16.7 0.6%
40-50 409.7 15.5% 130-140 7.4 0.3%
50-60 388.8 14.7% 140-150 2.0 0.1%
60-70 333.5 12.6% 150-160 0.4 0%
70-80 237.2 9.0% 160-170 0.2 0%
80-90 130.8 5.0% 170-180 0.1 0%
Spectral Power Distribution & Chromaticity Diagram
Page 10
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
10 / 16
Photometric Data
Page 11
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
11 / 16
Page 12
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
12 / 16
2.4 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
Test date 2019-01-24 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number 203012-215-XXX
Electrical Measurement for Bare-lamp:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
JBE190106-I
3
120.0 60 0.1138 13.12 0.9604 17.93
277.0 60 0.0520 13.10 0.9087 21.89
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 80 R9 0
Frequency (Hz) 60 R2 89 R10 73
CCT (K) 5046 R3 94 R11 80
Duv 0.0015 R4 81 R12 61
Chromaticity (x, y) x=0.3441 y=0.3537 R5 81 R13 83
Chromaticity (u’, v’) u'=0.2099 v'=0.4856 R6 84 R14 97
Color Rendering Index (CRI) 82.1 R7 85 R15 74
R9 0 R8 63 -- --
Photometric Measurement – Sphere-Spectroradiometer Method:
Parameter Result
Test Voltage (V) 120.0 277.0
Frequency (Hz) 60 60
Total Luminous (lm) 1594 1602
Luminous Efficacy (lm/W) 121.49 122.29
Worst Luminous/Highest Watts 121.49
Page 13
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
13 / 16
Spectral Power Distribution & Chromaticity Diagram
Page 14
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
14 / 16
2.5 Performance Assessment:
Model name CCT(K) Total Luminous
(lm) Power (W)
Luminous
Efficacy (lm/W)
203012-211-XXX 3000K 1501 13.05 115.02
203012-212-XXX 3500K 1524*1
13.09*2
116.42*3
203012-213-XXX 4000K 1548*1
13.09*2
118.26*3
203012-215-XXX 5000K 1594 13.12 121.49
*1: This value is calculated and the calculation formula is as below:
1524= (1594-1501)/4*1+1501
1548= (1594-1501)/4*2+1501
*2: This value is calculated and the calculation formula is as below:
13.09= (13.05+13.12)/2
*3: This value is calculated and the calculation formula is as below:
116.42= 1524/13.09
118.26= 1548/13.09
Page 15
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
15 / 16
3. Test Equipment
Equipment ID Equipment Name Last Calibration Date Next Calibration Date
ST-R-702 2 meter Integrating Sphere Verified by D204 standard lamp
ST-R-701 Spectral analysis system HAAS-2000 Verified by D204 standard lamp
ST-R-705 Standard Lamp 2018-02-08 2019-02-07
ST-R-704 Power Meter for Integrating Sphere 2019-01-06 2020-01-05
ST-R-714 Goniophotometer system Verified by D908S standard lamp
ST-R-710 Standard Lamp 2018-02-13 2019-02-12
ST-R-711 Power Meter for Goniophotometer 2019-01-06 2020-01-05
Uncertainty:
Photometric Measurement (Sphere):1.74%
Chromaticity Measurement(Sphere):14.3K
Photometric Measurement(Goniophotometer):1.62%
Page 16
Ningbo TengLi Testing Co., Ltd
2nd floor, Block B, Ningbo Testing and Certification Base, No. 66
Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang
Tel: 86574-8783 6802
Fax: 86574-8783 5902
Report No.: JBE190106-I
Report Format Number STD/QP019-409-A/0-NB
http://www.standard-tech.com
16 / 16
4. Product Photo
****** END OF REPORT ******