Top Banner
Presented by : - Philip Risi 2012 Live Line Live Line Technology Technology Live Line Arrestor (Firewall) Transformer Combi Unit (Transformer Protection) LIVE LINE TECHNOLOGY T (018) 468 3344 F (018) 468 3303 Distribution Line Lightning protection 3kv≤33kv
11

LLT Surge Protection Catalogue

Apr 15, 2017

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LLT Surge Protection Catalogue

Presented by : - Philip Risi 2012

Live Line TechnologyLive Line Technology

Live Line Arrestor (Firewall)

Transformer Combi Unit (Transformer Protection)

LIVE LINE TECHNOLOGYT (018) 468 3344F (018) 468 3303

Distribution Line Lightning protection 3kv≤33kv

Page 2: LLT Surge Protection Catalogue

2

1. Transformer Combi Unit– Change the arrestor & Fuse from ground

LLT Arrestor inserted upside down.

Easy insertion .

Hook & hinge exposed for easy connection.

Page 3: LLT Surge Protection Catalogue

1. Transformer Combi Unit– Change the arrestor & Fuse from ground

Page 4: LLT Surge Protection Catalogue

4

1. Transformer Combi Unit– Change the arrestor & Fuse from ground

Page 5: LLT Surge Protection Catalogue

5

1. Eliminate fuse blows & save Xfr’s

Surge Arrestor

Combi Configuration

The surge arrestor is connected in

parallel with the Fuse.

The surge arrestor protects both the

fuse and transformer.

Nuisance fuse blows eliminated.

Transformer protection enhanced.

Customer

Improved Service level.

Downtime eliminated.

Live Line capabilities.

Transformer

Prevention maintenance (level 4)

Circuit diagram of the Combi Configuration

Fuse

Page 6: LLT Surge Protection Catalogue

6

Eliminate the outage time :• Safety check & risk assessment. = 1 min.• Phoning control required for opening links at pole nr. +/- = 2 min.• Wear the FAS (Fall arrest system). = 2 min.• Install the portable earth kit. = 5 min.• Ladder, safety equipment climbing of pole. = 5 min.• Proceed to change the spare surge arrestor = 20 min.• Close links and finalize the safety checks.

Total time saved to replace arrestor = +/- 30 min

2. 2. SAIDI – Reduce time to replace arrestor

Page 7: LLT Surge Protection Catalogue

7

Drop Out surge arrestors – Drop Out surge arrestors – InstallationsInstallations Live line arrestors protecting a high lightning dense area. (improving the insulation co-ordination of the overhead lines.)

Spent arrestor in needs of replacing. No outage needed, with a link stick.

Page 8: LLT Surge Protection Catalogue

8

3. Firewall – Operation

Function of the Live Line Surge Arrestor :

To prevent over-voltage caused by lightning transients or surges.

On breakdown of the MOV blocks, the system frequency disconnects the faulty surge arrestor via the the GLD (Ground lead disconnector).

The surge arrestor, falls into the open position and can be replaced live line.Replace with a new unit

Polymer Housings

Metal Oxide Blocks ZnO

G.L.D

1. 2. 3.

Preventative maintenance (level 2)

Page 9: LLT Surge Protection Catalogue

9

3. Firewall – Installation Methodology

Damage

Line Protection

Best protection

Preventative maintenance (level 2)

Page 10: LLT Surge Protection Catalogue

10

3. Firewall & Combi unit

Combi unit set

Firewall setLine surge protection (draining incoming transients) in high lightning dense/intense areas)

Page 11: LLT Surge Protection Catalogue

End

The end – Combi protection