This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
We, at Cooling Tower Systems, greatly appreciate your interest in our cooling tower lines and related equipment.
Our cooling tower lines have been manufacturer for over 40 years, with five different models in production. We are the oldest, full-service fiberglass cooling tower manufacturer in the industry today. All our towers are designed, engineered and tested by our own factory R&D laboratory. We feel our towers are considered second to none in quality and energy efficiency, and are much more cost effective when compared to other cooling tower manufacturers.
We have been a member of the Cooling Tower Institute (C.T.I.) since 1972 and rate our cooling towers per their specifications, have standard specifications and C.T.I. certification on our LRC model line.
The additional products we represent have all been selected to compliment each other in order that we may provide complete mechanical packages. We have O.E.M. agreements with all of our suppliers so that we can be very competitive in today's marketplace and supply the best equipment to our suppliers and customers.
We have numerous cooling towers installed across the United states and have a very satisfied customer base to include national account agreements with some of the nation's largest supply houses. Our company provides technical assistance and product data throughout the United States and to international markets for our industrial contractors, mechanical consulting and design engineers, chemical manufacturers, food and beverage manufacturers and processors, refrigeration warehouse companies, industrial buyers and utility companies and a very large dry cleaning market.
We are looking forward to doing business with your company. Regards,
www.coolingtowersystems.com - 2 - Over 40 Years of Manufacturing Experience
Introduction Letter..................................................................................... 1 Table of Contents...................................................................................... 2 Terms and Conditions............................................................................... 3 Cooling Tower Specifications.................................................................. 4 - 5 Cooling Tower List Price.......................................................................... 6 Stainless Steel Optional Add-On List Price............................................ 7- 8 Low Noise Cooling Tower List Price....................................................... 9 Cooling Tower Replacement Parts List Price......................................... 10-13 Fan Motor List Price.................................................................................. 14 V Belt Speed Reducer Parts List Price.................................................... 15 V Belt & Gear Reducer List Price............................................................ 16 Anti Splash Louver List Price................................................................... 17 Extension Skirt List Price......................................................................... 18 Vertical Remote Sump Tank List Price.................................................... 19 Vertical Storage Tank Specs.................................................................... 20 Winterization Basin Heaters & Heater Control Panel............................. 21 Heater and Control Panel Specifications................................................ 22-23 Vibration Isolation Mounts List Price...................................................... 24 Man Hours Assembly Table...................................................................... 25 Assembly Drawings & Parts Tables for Cooling Towers T-25 through T-3000
T-25 through T-230................................................................................. 26-27 T-240 through T-260............................................................................... 28-29 T-270 through T-2125............................................................................. 30-31 T-2150 through T-2350........................................................................... 32-35 T-2400 through T-3000........................................................................... 36-37
www.coolingtowersystems.com - 3 - Over 40 Years of Manufacturing Experience
Sales: Cooling Tower Systems sells its goods on the expressed condition that the buyer agrees to the terms and conditions stated hereon. The buyer relinquishes any inconsistent or additional terms included in any purchase order. The buyer's acceptance and receipt of the goods shall compose any agreement to such terms and conditions.
Acceptance: All orders are subject to Cooling Tower Systems and Sales department approval and acceptance. Cooling Tower Systems reserves the right to end further delivery upon the buyer's failure to pay any portion of any order, when it becomes due. If the buyer's financial condition becomes unsatisfactory, Cooling Tower Systems may require cash payments or satisfactory security for future deliveries or goods already delivered.
Cancellation: Buyer shall not cancel the order without prior written consent of Cooling Tower Systems.
Deliveries: Cooling Tower Systems shall not be liable for delays in delivery due to causes beyond its reasonable control including but not limited to strikes, fire, war, or acts of God, whether such events occur at or about our warehousing facilities or at the warehousing facilities of our suppliers. Cooling Tower Systems makes no guarantee of shipment by any such date and shall have no liability or other debt for failure to ship on such date due to any cause.
Shipping: The price of all products is F.O.B. Cooling Tower Systems warehousing facilities. Title to goods passes to the buyer upon deliver by Cooling Tower Systems to the freight line. Buyer assumes risk for all goods shipped. The buyer should examine shipments carefully for loss or damages before accepting the shipment. The buyer should have loss and damage noted by transportation agent on the freight bill when accepting delivery. Upon discovery of concealed damage the buyer has fifteen (15) days from receipt of goods to call the freight line for an inspection. In either case, the buyer cannot return equipment to Cooling Tower Systems until completion of a freight inspection. In absence of shipping instructions, Cooling Tower Systems shall use its own discretion in choice of carrier.
Return Policy: Cooling Tower Systems accepts only new and unused material returned for credit. Cooling Tower Systems will charge a minimum of 20% for restocking all material accepted for credit. Buyer must return all goods freight prepaid. Cooling Tower Systems will not accept any goods returned after thirty days.
Cash Discount & Terms: Cooling Tower Systems may charge 1.5% each month on all sums more than thirty (30) days past due. The first charge will be added on the sixty-first (61st) day after the date of invoice. A 2% cash discount on parts and equipment will be issued if the invoice is paid within ten (10) days after invoice.
Prices: All prices are subject to change without notice.
Terms & Conditions
www.coolingtowersystems.com - 4 - Over 40 Years of Manufacturing Experience
COOLING TOWER SPECIFICATIONS:
Furnish and install an induced-draft, counter flow, field erected, FRP and stainless steel cooling tower of _____ cell(s) as shown on plans. Tower shall be similar and equal to Cooling Tower Systems Model _________.
CAPACITY:
Tower shall be capable of cooling ___________ GPM for water from __________ F. to __________ F. at a design engineering wet bulb temperature of ___________ F. and that the thermal performance shall be guaranteed to perform per plans and specs. After installation if, due to a suspected thermal performance deficiency, the owner chooses to conduct an on-site thermal performance test under supervision of a qualified, disinterested third party, and witnessed by the manufacturer, in accordance with the CTI or ASME standards during the first year of operation, and if the tower fails to perform within the limits of test tolerances; then the cooling tower manufacturer will pay for the cost of the test and will make such corrections as are appropriate and agreeable to the owner to compensate for the performance deficiency.
CONSTRUCTION:
The cold water basin, casing section shall be constructed of fiberglass-reinforced polyester (FRP). Fasteners and all other associated hardware shall be constructed of 304 Stainless Steel, (SUS). All other standard metal components, such as supports, grilles, or tower supports, are to be constructed of Hot Dipped Galvanized Steel, (H.D.G.S.), unless otherwise specified by customer. (Can be 304 SUS or 316 SUS).
MECHANICAL EQUIPMENT:
Fan(s) shall be propeller type, incorporating heavy-duty cast aluminum blades. Blades shall be individually adjustable and replaceable. Fan Assemblies shall be driven via standard V-Belt Reducers or Gear Reducers, V-Belt Speed Reducers and Gear Reducers shall be completely enclosed to protect the pulleys, drive-belts, and gears. Fan motors shall be Totally Enclosed, (TEAC), reversible squirrel cage ball bearing type, and designed specifically for cooling tower service.
WET DECK SURFACE:
The wet deck surface shall be formed from polyvinyl chloride (PVC) and shall be impervious to rot, decay, and fungus or biological attacks and performance tested by the manufacturer to insure responsibility and quality control of the final product.
www.coolingtowersystems.com - 5 - Over 40 Years of Manufacturing Experience
HOT WATER DISTRIBUTION SYSTEM:
The PVC hot water distribution system consisting of sprinkler arms and aluminum or stainless steel sprinkler head, as specified, to deliver incoming water by pump water pressure through a single water inlet connection ensuring even distribution over the wet deck surface.
COLD WATER BASINS AND ACCESSORIES:
The (FRP) cold water basin shall be watertight and include a brass float operated mechanical make-up valve. From the lip of the cold water basin to the bottom edge of the casing section shall be enclosed by a polyvinyl chloride (PVC) screen to prevent debris from entering the cold water basin and water splash out.
SCOPE OF WORK IF REQUIRED:
By owner/contractor... The cooling tower manufacturer shall be responsible for the design, fabrication, and delivery of materials to the work site, and for the erection of the tower on supporting piers or grilleage furnished by owner/contractor.
ACCESSORIES:
Listed in the Cooling Tower Systems catalog it includes all Stainless Steel components hardware vibration cut-out switches, variable speed drives, remote sump tanks, cold water basin heaters and controls, water pumps, and plate heat exchangers.
WARRANTY: (1) The manufacturers shall warrant the fiberglass basin and casings for ten (10) years. (2) (2) Wet Deck Polyvinyl Chloride (PVC) for two (2) years. (3) Fan Motor for one (1) year. (4) Extended Warranties are available upon request, for an additional fee.
Specifications (Continued)
Variable Speed Drive
www.coolingtowersystems.com - 6 - Over 40 Years of Manufacturing Experience
Please Contact the Sales Office for Pricing on Model
Towers T-2200 & Above
(1) PRICES ARE F.O.B. CLOSEST STOCKING WAREHOUSE. (2) a. T-25 THROUGH T-280 ARE ASSEMBLED TOWERS. b. T-2100 THROUGH T-2175 REQUIRE FIELD ASSEMBLY OR CAN BE ASSEMBLED IN SHOP, WITH IN-HOUSE ASSEMBLY CHARGE AND SHIPPED VIA WIDE LOAD FREIGHT PERMITS. CHECK WITH SALES OFFICE FOR MOST COST EFFECTIVE WAY FOR YOUR PARTICULAR INSTALLATION. c. T-2200 AND ABOVE REQUIRE FIELD ASSEMBLY. FACTORY FIELD ASSEMBLY IS AVAILABLE IF REQUIRED. CALL SALES OFFICE FOR THESE QUOTES. (3) MOTOR FREIGHT RATES: CLASS 150 WITH 35% DISCOUNT. (4) FAN MOTORS ARE AVAILABLE IN TRI-VOLTAGE 208/230/460/3. IF REQUIRED, AS WELL AS 50
CYCLE FAN MOTORS. CALL SALES OFFICE FOR INFORMATION. (5) MODEL T-2225 AND LARGER, PLEASE CONTACT SALES OFFICE FOR FORMAL QUOTATION.
Cooling Tower List Price
www.coolingtowersystems.com - 7 - Over 40 Years of Manufacturing Experience
T MODEL (A) (B) (C) (D) (E) (F) (G) (H) (I) (J) TOTAL
1. Metric Type Motor (IEC Standard) - Three Phase X 60HZ X 220/440 Volt X E Class Insulation A. 1/6HP X 6P to 7.5HP X 4P - Totally Enclosed Non-Ventilation Type (TENV). B. 5 HP x 10 – Totally Enclosed Fan Cooled (TEFC) C. 10 HP X 4P to 40HP X 4P - Totally Enclosed Fan Cooled Type (TEFC).
2. NEMA Type Motor (NEMA Standard) - 3 Phase X 60HZ X 208/230/460 Volt X B Class Insulation A. 1/2HP X 6P to 3HP X 8P - Totally Enclosed Non-Ventilation Type (TENV). B. 5HP X 10P to 40HP X 4P - Totally Enclosed Fan Cooled Type (TEFC).
www.coolingtowersystems.com - 16 - Over 40 Years of Manufacturing Experience
MODEL # REDUCER MODEL # SPEC. # QUANTITY LIST PRICE EACH LIST PRICE SET T-2225 LBM-055C 2-11Ms-800 1 PC 111 279 T-2250 3-11Ms-800 1 PC 168
T-2300 LBM-075 2-11Ms-800 2 PC 111 389 T-2350 3-11Ms-800 1 PC 168
T-2400 LBM-110 2-11Ms-1400 1 PC 137 347 T-2500 3-11Ms-1400 1 PC 210
T-2600 LBM-150 2-11Ms-1400 2 PC 137 483 T-2700 3-11Ms-1400 1 PC 210
T-2800 LBM-220 2-11Ms-1550 2 PC 153 756 T-3000 3-11Ms-1550 2 PC 226
• The Manufacturer recommends when replacing V-Belts the complete set be replaced to eliminate premature wearing. For optimal V-Belt usage, be sure that the match set numbers are within five (5) match points.
1. To meet available "Pinion size on Gear Reducer" the shaft dimension on the Fan Motor is specially designed.
2. To meet available flange size on Fan Motor the Gear Reducer will have an "Adaptor" on the top. 3. To meet Motor Mounting Frame and Fan Hub size on cooling tower the Gear Reducer will have an
"Adaptor" on the top. 4. Gears are manufactured by "Flender Himmelwerk & Co. KG" in Germany.
V-Belt List Price
Gear Reducer Price List
Anti-Splash Louver List Price
www.coolingtowersystems.com - 17 - Over 40 Years of Manufacturing Experience
MODEL # # OF UNITS WIDTH OF UNITS LENGTH OF BLADE LIST PRICE T-25 3 35 8 $195.00 T-28 3 35 8 195 T-210 3 44 8 238 T-215 3 48 12 296
THE LIST PRICING ABOVE INCLUDES DRAIN FITTING ONLY. FOR 1" BULKHEAD FITTING - LIST PRICE $40.00; 2" BULKHEAD FITTING - LIST PRICE $55.00; 3" BULKHEAD FITTING - LIST PRICE $105.00. FOR FITTINGS OVER 4", CONTACT CTS FOR PRICING.
BULKHEAD FITTING CAN BE INSTALLED FOR A NET COST OF $15.00/EACH.
Vertical Remote Sump Tanks List Price
Water Pump
CTS
Accessory Item
www.coolingtowersystems.com - 20 - Over 40 Years of Manufacturing Experience
Vertical storage tanks are most frequently used for nursing mobile application equipment
and bulk storage. Common uses are for fertilizer solutions, ag chemicals, plant foods,
liquid feeds and water.
Features include tie-down slots, built-in graduation gallon-count indicators, siphon tube, offset fill-well and self-vented, slosh-
proof lids.
Gallon Capacity
Diameter (IN.)
Height (IN.)
Fill Opening
(IN.) Drain (IN.)
Premium Weight -White- Item No.
Premium Weight
Tank Availability
Location
Heavy Weight -Blue-
Item No.
Heavy Weight Tank
Availability Location
65 23 38 8 1 1/4 60213 A - - 165 31 55 16 2 40281 A - - 300 35 78 16 2 40213 A - - 305 46 48 16 2 40302 A - - 500 48 71 16 2 40148 B, C, D, E - - 500 46 78 16 2 40304 F 40306 F 550 67 42 16 2 40023 A - - 750 46 112 16 2 40308 F - - 1000 64 79 16 2 40152 A 40154 F 1100 87 51 16 2 40070 A 40081 C, F 1300 87 58 16 2 40035 B, C 40036 B 1500 64 115 16 2 40144 A 40146 B 1550 87 65 16 2 40235 A 40236 - 1610 100 56 16 2 40199 C - - 1700 87 70 16 2 40010 A 40012 - 2100 87 87 16 2 40178 A 40241 - 2500 95 89 16 2 40051 A 40052 - 3000 95 105 16 3/2 40063 A 40065 - 4000 95 140 16 3/2 40076 B 40117 - 4000 102 125 16 3/2 40312 C, D, E, F 40314 - 5000 102 151 16 3/2 40164 A 40166 - 5800 141 97 16 3/2 40071 C - - 6000 102 182 16 3/2 40226 A 40233 - 6500 120 147 16 3/2 40224 A 40232 - 7000 141 117 16 3/2 40347 F 40349 - 9000 141 144 16 3/2 - - 40231 A
10,000 141 159 16 3/2 - - 40353 A 12,000 144 185 16 3/2 - - - A
*NOTE: For drawings to indicate fitting location, contact Sales Office
Vertical Storage Tanks
www.coolingtowersystems.com - 21 - Over 40 Years of Manufacturing Experience
TABLE 1: Single phase heater with built-in load carrying 0-100° F thermostats. Single Phase Amperage
Tower Model No. Heater Catalog No. Watts 120V 208V 240V List Price* T-25, T-28 712U221312 750 6.3 3.6 3.2 $576.14
T-2100 713U211312 6000 N/A 28.9 25.0 738.21 *Add $159.30 to all heaters for double pole thermostats. Prices above are for single pole, single throw only.
TABLE 2: Single phase heaters, no thermostats, for use with control panel option. Single Phase Amperage
Tower Model No. Heater Catalog No. Watts 120V 208V 240V List Price* T-25, T-28 712U121300 750 6.3 3.6 3.2 $289.88
Heater Control Panel: Order catalog number 874U-100000. Panel is NEMA 4 with pre-mounted electrical hubs for conduit connection, combination temperature and low water cutoff controller, probe and weatherproof connector, contactor, and control power transformer. UL labeled and listed. Panel rating is 40 amps. List Price $1,112.10
www.coolingtowersystems.com - 22 - Over 40 Years of Manufacturing Experience
Cooling Tower Applications Cooling tower operation is often required in freezing weather for either comfort air conditioning in the central core of a large building, or for industrial processes. To protect the cooling tower from freezing during shutdown periods, Cooling Tower Systems has developed a full line of winterizing heaters. Those shown in this section are used when heat distribution is required over a long length, or when an over-the-side construction is required, as in ceramic, concrete or fiberglass basin. 2" pipe thread heaters, with copper tubular elements are commonly used in the sump when full-length distribution is required. Alternately, to protect both the tower and its piping, the water may be pumped through an Instantaneous Heater. Construction
Two Constructions are available:
Pipe Thread Heaters are furnished with a Scru-Tite hub, which has a
built-n O-ring and locknut to make a pressure-tight joint through a hole in
metal basin walls. The heater is screwed into this hub in the field.
Over-the-Side Heaters eliminate the necessity for cutting a hole in a metal basin and are desirable for installations in non-metal basins. Internal wiring runs from the horizontal heater elements through a vertical riser and extension arm with an outlet box located over the side of the basin. Adjustable Sludge Legs are furnished on all heaters. They are located on five foot centers to keep the element in place even in high water velocities. The legs are adjustable for heights between 2" and 3-1/2"; longer legs are available on special order.
Elements - Both constructions utilize an 80/20 nickel/chromium resistance coil strung through cylindrical ceramic cores. This assembly is slipped into a Type 304 Stainless Steel sheath. All voids are filled with magnesium oxide.
Elements are available in two sizes: Series 761 hearts have 3/4" diameter elements for single phase operation up through 480 volts, and are most commonly used. Series 762 heaters have 1 1/4" diameter elements for both single and three phase operation, up through 480 volts, and in higher KW ratings (up to 20 KW). Consult our office for specific wattage limitations at various voltages.
Element lengths up to 240" are listed in the accompanying table and are available from stocked tubing. Lengths up to 360" are available on special order.
Liquidproof/Explosion-Resistant Outlet Boxes are furnished on all heaters.
Controls Thermostats and low water cutoffs are stocked and available as individual components or mounted and pre-wired into NEMA 4 control Panel-boards. Accessories for controls are designed for mounting through a basin wall. Consult factory for pricing.
Thermostats, required to energize the heater as the water temperature reaches the freezing point, are bulb and capillary devices with a 35° to 110° F range and a fixed 3° F differential. Each thermostat is furnished with a stainless steel well to house and permanently locate the bulb. The well is installed through a Scru-Tite hub, also furnished, which should be at the same level as the heater.
Heaters
Heater’s Continued
www.coolingtowersystems.com - 23 - Over 40 Years of Manufacturing Experience
The thermostat is normally housed in a NEMA 4 weatherproof enclosure, which can be located up to 3 feet away from the well. For indoor or protected installations, the thermostat is available in a NEMA 1 sheet metal enclosure. In most instances, the heater load can be carried directly by the thermostat, which has the following non-inductive single phase ratings: 3000 Watts at 120 Volts 4575 Watts at 208 Volts 5280 Watts at 240 Volts 4985 Watts at 277 Volts Three phase heaters, 480 volt heaters, and those with ratings exceeding the above require a magnetic contactor. See Bulletin C81-2.
Low Water Cutoff - If the heater is operated when it is not completely covered with water, irreparable damage may result. The low water cutoff prevents such damage. It consists of two components: A Type 316 Stainless Steel probe, installed at least 2" above the element heating; and a relay to deenergize the heater when the water level drops below the probe. A weatherproof cord connects the probe and relay. The relay is capable of carrying heater loads up to 20 amps at 110 volts and 16 amps at 220 volts, single phase. Above this capacity, a magnetic contactor is required.
NEMA 4x Panel Board - Dimensions 6" x 12" x 10". Designed for cooling tower applications. Built in: 0 to 100°F thermostat calibrated for freeze protection. Low water cutoff - floatless type with low voltage probe. 3 pole contactor rated 40 amps. Accessories for mounting sensors through basin with 2" NPT pip plug specify power voltage 120, 280, 240 or 480. Stock item available for quick delivery.
UL Listing - Both Pipe Thread and Over-the-Side constructions are listed by the Underwriters' Laboratories under Reference E23541 in lengths through 240" and ratings through 40 amps (24 amps at 480 volts, 3 phase). This broad UL listing insures both the purchaser and electrical inspector of safe operation with a wide variety of operating characteristics.
How To Order Specify: 1. Catalog Series Series 761 for 3/4" diameter. (Single phase only) Series 762 for 11/4" diameter. (Single or three phase) 2. Element Length See listings. Consult factory for lengths over 240". 3. Type of Construction Pipe Thread or Over-the- Side. For over-the-side construction, specify riser height (C-Dimension).
4. Sludge Leg Height If legs must be higher than 3 1/2". 5. Voltage 120, 208, 240, 277 and 480 volts are standard. Specify "Special Voltage" if required (no extra charge). 6. KW Rating Consult your local representative for advice on KW rating required to prevent freeze up. Most KW ratings available in length and diameter required. 7. Thermostat Catalog No. 230-12WCL for NEMA 4 enclosure; Catalog No. 230-12WC for NEMA 1 enclosure. Well and Scru- Tite hub automatically furnished. 8. Low Water Cutoff Catalog No. B-1480 includes relay in NEMA 4 enclosure, Probe, Scru-Tite hub, bushing, cord and connector. Control voltage will be the same as heater voltage except in the following cases where you must specify control voltage. If heater: (1) draws more than 20 amps at 110 volts or 16 amps at 220 volts, or (2) is three phase. 9. Flange for Mounting Low Water Cutoff and Thermostat Well Through Wooden Tower Standard CTS cooling tower heaters are built with Scru- Tite hubs for mounting through a metal basin. If it is necessary to mount the heater through a basin wall that is other than metal, e.g., wood, heaters can be furnished with flanges for low water cutoff and thermostat well.
www.coolingtowersystems.com - 24 - Over 40 Years of Manufacturing Experience
MODEL CTS NO. OF MT. PTS ISOLATION TYPE LIST PRICE
SLR - RESTRAINED SPRING MOUNTS SLR Restrained Spring Mounts provide control of structurally transmitted noise and vibration, with limited movement. Equipment is restrained in all directions, therefore, reducing damage caused by conditions that would otherwise move equipment excessively. SLR Restrained Spring Mounts are ideal for protecting connections to Cooling Towers where weight can change with fluid fluctuations that cause the units to move vertically. They also meet or exceed most building code requirements where earthquakes and high wind load conditions are experienced.
Vibration Isolation Mounts List Price
Vibration Isolator
www.coolingtowersystems.com - 25 - Over 40 Years of Manufacturing Experience
Cooling Tower Systems ships FOB from closest available warehouse. This includes full assembly of cooling towers T-25 through T-280 models. Models T-2100 and larger require field assembly due to size and shipping costs.
We at Cooling Tower Systems have field engineers available for field assembly for any location in North America. For further information on your special field assembly requirements and prices, call our convenient toll free number and ask a sales representative for details.
Cooling Tower Systems has had numerous inquiries from our wholesale customers regarding the assembly time required for field assembly of our cooling towers. The following table has been compiled to assist our customers and should be used as a guide only.
Model Number Men required Hours per Man T-25 to T-215 1 1
T-2100 to T-2125 3 5 T-2150 to T-2175 3 7 T-2200 to T-2250 4 8 T-2300 to T-2350 4 12 T-2400 to T-2500 5 18 T-2600 to T-2700 5 24 T-2800 to T-3000 5 40
NOTE: (1) MODELS T-25 THROUGH T-280 SHIPPED ASSEMBLED AND ASSEMBLY PRICE IS INCLUDED IN TOWER PRICE. (2) MODELS T-2100 THROUGH T-2175 CAN BE FACTORY ASSEMBLY AND SHIPPED WITH OVERWIDTH PERMITS. CALL SALES OFFICE FOR ASSEMBLY AND SHIPPING COSTS.
Man Hours – Assembly Table
Winterization Kit
Accessory Item
www.coolingtowersystems.com - 26 - Over 40 Years of Manufacturing Experience
T-25 thru T-230 Cut Sheet
www.coolingtowersystems.com - 27 - Over 40 Years of Manufacturing Experience
Water Basin Sealing Material A Fiberglass 1 Set B Polyester Resin 1 Keg C Catalyst 1 Bottle
*Please check the above mentioned parts within two weeks after the goods are received.
T-2400 Through T-3000 Parts Table
www.coolingtowersystems.com - 38 - Over 40 Years of Manufacturing Experience
SAMPLE WARRANTY
ONLY!!!
Warranty Cooling Tower Systems, Inc. is pleased to provide _____________ , located at: ________ _______ . Purchase Date: Model No.: Serial No.: Motor Fan No.: Frame No.: V-Belt Speed Reducer No. (If Applicable): DOMESTIC – WITHIN THE CONTINENTAL UNITED STATES: A. Ten Years on FRP, (fiberglass) casing, and cold water basins. B. Two (2) years on all PVC fillings. C. One (1) year on all fan motors, major drive components, and all internal moving parts, only. NOTE: An Extended Manufacturer’s Warranty is available, for an additional nominal fee, and is set into place as part of the original purchase. INTERNATIONAL ORDERS/WARRANTY: A. Eighteen (18) months, after shipping date. B. One (1) year, after initial start-up of Cooling Tower. C. *Note – only “A” or “B” is applicable, which ever comes first. We at Cooling Tower Systems, Inc. Thank You for your patronage and look forward to adding you as a satisfied customer. With Best Regards, Joe Coates, President Cooling Tower Systems, Inc. 196 Lower Cherry Street Macon, GA 31201 478-755-1905 / 800-752-1905 Email: [email protected] Website: www.coolingtowersystems.com