Page 1 LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES When mounting Solibro modules from generation G1.4 or higher with the specified clamps, section 2 "Planning" of the valid installation and operation manual under: 2.2 "Requirements on the clamp system for unframed modules" 2.2 "Requirements on the clamp system for framed modules" 2.3 "Mounting options" must be observed. CLAMPS FOR UNFRAMED MODULES [SL2] SOLIBRO CLAMP - SC1 (120 mm) Manufacturer: Alumero Article number: Middle and End clamp are identical 22235 (black) 22234 (natural aluminum) MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa] TEST LOAD WITH SAFETY FACTOR γ m =1.5 [Pa] COMMENT SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm. Torque: 15-20 Nm Tensile load 1600 Tensile load 2400 SOLIBRO CLAMP - SC2 (120 mm) Manufacturer: Alumero Article number: Middle clamp 22285 (black) 22283 (natural aluminum) End clamp 22286 (black) 22284 (natural aluminum) MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa] TEST LOAD WITH SAFETY FACTOR γ m =1.5 [Pa] COMMENT SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm. Torque:10-18 Nm Tensile load 1600 Tensile load 2400 The required clamping force can be found in the manufacturer information. The fixing screws must be aligned with the substructure rails. The use of clamping systems which are not approved by Solibro can result in modules breaking, which in turn can cause electrical hazards that represent a danger to life and limb and a risk of material damage!
7
Embed
LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES
When mounting Solibro modules from generation G1.4 or higher with the specified clamps, section 2 "Planning" of the valid installation and operation manual under:2.2 "Requirements on the clamp system for unframed modules" 2.2 "Requirements on the clamp system for framed modules" 2.3 "Mounting options" must be observed.
CLAMPS FOR UNFRAMED MODULES [SL2]
SOLIBRO CLAMP - SC1 (120 mm)
Manufacturer: Alumero Article number:Middle and End clamp are identical22235 (black)22234 (natural aluminum)
SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm.Torque:10-18 NmTensile load 1600 Tensile load 2400
The required clamping force can be found in the manufacturer information. The fixing screws must be aligned with the substructure rails.
The use of clamping systems which are not approved by Solibro can result in modules breaking, which in turn can cause electrical hazards that represent a danger to life and limb and a risk of material damage!
Page 2LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES
CLAMPS WITH GROUNDING FUNCTION FOR FRAMED MODULES [SL2-F]
ALUMERO (50 mm)
Manufacturer: Alumero Article number:Grounding middle clamp without screw17171 (black)15446 (natural aluminum)End clamp without screw17211 (black)17210 (natural aluminum)Grounding plate16075
SL2-F Point mounting Pressure load 3600 Pressure load 5400 Only use as a system with Mounting Systems sub-structure rails.Tensile load 1600 Tensile load 2400
Page 4LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES
SL2-F Point and linear mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm. For black anodized clamps, a screw with lock-ing serration must be used.
SL2-F Point mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm.
Tensile load 1600 Tensile load 2400
Page 6LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES
MOUNTING SYSTEMS FOR UNFRAMED MODULES [SL2]
SOLIBRO
Manufacturer Solibro
Name of system Slide-In
Type of application Free field
Mounting variant Detachedly elevated system
Permitted inclination 20° – 60°
Design Load for pressure and tensile* 2,000 Pa
Test Load for pressure and tensile 3,000 Pa
Notice Mounting on a separate substructure
The currently valid installation manual for the Solibro Slide-In System must be applied for the installation. The requirements of the substructure can be requested from the respective manufacturer.
*Max. system load equals max. permissible module load
SUNBEAM
Manufacturer Sunbeam
Name of system Sunbeam symmetrical
Type of application Flat roof with the max. inclination of 5°
Mounting variant Elevated system
Mounting inclination 2 x 10°
Design Load for pressure and tensile* 1,600 Pa
Test Load for pressure and tensile 2,400 Pa
Type of roof** Flat roof: foil and bitumen roof
Roof connection** Flat roof: ballasting
*Max. system load equals max. permissible module load* * Mounting according to the manufacturer‘s specification and the structural
analysis
CALYXO
Manufacturer Calyxo
Name of system MX
Type of application Flat roof, tilted roof
Mounting variant Parallel to the roof
Design Load for pressure and tensile* 2,000 Pa
Test Load for pressure and tensile 3,000 Pa
Type of roof** Flat roof: foil and bitumen roofTilted roof: tile and metal roof