16 Te Limit switches Double insulated, types XCK-P and XCK-T Presentation With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever) or multi-directional operators Page 20 With head for linear movement (plunger) operators Page 22 With head for rotary movement (lever) or multi-directional operators Page 24 XCK-P with 1 cable entry, conforming to CENELEC EN 50047 XCK-T with 2 cable entries, compatible with CENELEC EN 50047 (Tripping/resetting points and fixing centres conform to CENELEC EN 50047)
10
Embed
Limit switches - RS ComponentsTe 17 Limit switches Double insulated, types XCK-P and XCK-T General characteristics Environment Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
16 Te
Limit switchesDouble insulated, types XCK-P and XCK-T
Presentation
With head for linear movement (plunger) operators
Page 18
With head for rotary movement (lever) or multi-directional operators
Page 20
With head for linear movement (plunger) operators
Page 22
With head for rotary movement (lever) or multi-directional operators
Limit switchesDouble insulated, types XCK-P and XCK-T
General characteristics
Environment
Conforming Products IEC 947-5-1, IEC 337-1, EN 60 947-5-1, NF C 63-146, VDE 0660-200, UL 508, CSA C22-2 n° 14to standards
Machine assemblies IEC 204-1, EN 60 204-1, NF C 79-130
Approvals CSA A300, UL A300 Listed, NEMKO FI 10 (4) A-400 V
Protective treatment Standard version : “TC” and “TH”
Ambient air temperature Operation : - 25…+ 70 °C. Storage : - 40…+ 70 °C
Vibration resistance 25 gn (10…500 Hz) conforming to IEC 68-2-6
Shock resistance 50 gn (11 ms) conforming to IEC 68-2-27
Electric shock protection Class II conforming to IEC 536 and NF C 20-030
Degree of protection IP 65 conforming to IEC 529 ; IP 653 conforming to NF C 20-010
Repeat accuracy 0.1 mm on the tripping points
Cable entry Depending on model : tapped entry for n° 11 or 13 cable gland(s), or tapped M16 or tapped 1/2" NPT
Contact block characteristics
Rated operational characteristics ccccc AC-15 ; A300 (Ue = 240 V, Ie = 3 A)aaaaa DC-13 ; Q300 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1
Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 947-1 and VDE 0110, group C conforming to NF C 20-040Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated withstand impulse voltage U imp = 6 kV conforming to IEC 947-1, IEC 664
Positive operation (Dpg. on model) N/C contacts with positive opening operation conforming to IEC 947-5-1 Section 3, EN 60 947-5-1
Resistance across terminals ≤ 25 mΩ conforming to NF C 93-050 method A or IEC 255-7 category 3
Short-circuit protection 10 A cartridge fuse type gG (gl)
Cabling Screw and captive cable clamp terminals.XES-Piiiii151 and XES-P2141 : Clamping capacity, min. : 1 x 0.34 mm2, max. : 2 x 1.5 mm2
XEN-P21iiiii1 and XEN-P31iiiii1 : Clamping capacity, min. : 1 x 0.5 mm2, max. : 2 x 2.5 mm2
Minimum actuation speed XES-P iiiii151 and XES-P2141 : 0.001 m/minute, XEN-P21iiiii1 and XEN-P31iiiii1 : 0.001 m/second
Electrical durability Conforming to IEC 947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Maximum operating rate : 3600 operating cycles per hour.Load factor : 0.5
d.c. supply a Power broken in W for 5 million operating cycles Power broken in W for 5 million operating cycles
Voltage V 24 48 120 Voltage V 24 48 120
p W 10 7 4 p W 13 9 7For XES-Pi151 on c or a, N/C and N/O contactssimultaneously loaded to the values shown with reversepolarity.
Current in A Current in A
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V230/400 V
2 3 4
Ithe
24 V
0,5 1 2 3 4 5 100,1
0,2
0,5
1
5
2
43
Ithe
230 V 12/24/48 V
110 V
Mill
ions
of
oper
atin
g cy
cles
Mill
ions
of
oper
atin
g cy
cles
18 Te
1314 22
21
1211
2221
1314 24
23
2221
1413
1314 22
21
Limit switchesDouble insulated, conforming to CENELEC EN 50047, type XCK-PComplete switches with 1 cable entry, tapped M16 x 1.5
References, characteristics
Type of operating head Plunger
Type of Metal end plunger Steel end plunger Thermoplastic Thermoplastic roller lever plunger, 1 direction of actuationoperator with elastomer roller plunger horizontal vertical horizontal or
boot vertical
References ( N/C contact with positive opening operation)
(1) 1 cable entry, tapped M16 x 1.5 for ISO cable gland Ø : 2 elongated holes Ø 4.3 x 8.3 on 22 centres, 2 holes Ø 4.3 on 20 centres
1,8
0 5mm0,9
4,5(P)21-2213-1421-2213-14
1,8
0 5mm0,9
4,5(P)21-2213-1421-2213-14
3,1(A)21-2213-1421-2213-14
0 mm1,5
7,8(P) 6,5(A)
0 mm3
15,7(P)21-2213-1421-2213-14
6,5(B)
0 mm3
15,7(P)21-2213-1421-2213-14
9,8(A)
0 mm4,9
22,5(P)21-2213-1421-2213-14
9,8(A)
0 mm16,1
17,2(P)21-2213-14
6,5(B)
0 mm10,5
11,3(P)21-2213-14
6,5(A)
0 mm10,5
11,3(P)21-2213-14
3,1(A)
0 mm5,2
5,6(P)21-2213-14
1,8
0 5mm3
3,2(P)21-2213-14
1,8
0 5mm3
3,2(P)21-2213-14
8,1(B)
0 mm5,321-2213-14
5,2
0 mm3,1
7,6(P)21-2213-14
3
0 5mm1,8
4,4(P)21-2213-14
3
0 5mm1,8
4,4(P)21-2213-14
10,9(A)
0 mm6,6
16(P)21-2213-14
10,9(B)
0 mm6,6
16(P)21-2213-14
6,6(B) 11,6(P)
0 mm11-1221-22
5,3(A)
0 mm11-1221-22
6,6(A) 11,6(P)
0 mm11-1221-22
5,6(P)
0 mm
3,111-1221-22
1,8
0 5mm
3,2(P)11-1221-22
1,8
0 5mm
3,2(P)11-1221-22
5,3(A)
0 mm13-1423-24
6,6(B)
0 mm13-1423-24
1,8
0 5mm13-1423-24
1,8
0 5mm13-1423-24
3,1(A)
0 mm13-1423-24
6,6(A)
0 mm13-1423-24
Ø
30
20/22= =
30,5
Ø11
4
30
(1)
8525
3,5
12,5
30
(1)
74,525
12,5
30
20/22= =
20
Ø8
Ø4
30
(1)
74,525
12,5
Ø
30
20/22= =
20
Ø8
4
30
(1)
93,5
25
5,5
12,5
Ø
30
20/22= =
39
Ø14
204
30
(1)
95,5
25
5,5
12,5
Ø14
Ø
30
20/22= =
41
12,5
22
4
30
(1)
104,
5
25
6
12,5
30
20/22= =
50Ø22
31
2,52,5
312
Ø4
20 Te
1314 22
21
1211
2221
1314 24
23
2221
1413
1314 22
21
Limit switchesDouble insulated, conforming to CENELEC EN 50047, type XCK-PComplete switches with 1 cable entry, tapped M16 x 1.5
References, characteristics
Type of operating head Rotary Multi-directional
Type of Thermoplastic Variable length Square rod Round rod “Cat’s whisker”operator roller lever (1) thermoplastic u 3 mm Ø 3 mm
roller lever (2) steel (2) glass fibre (2)(1) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(2) Adjustable throughout 360° in 5° steps.
References ( N/C contact with positive opening operation)
(1) 2 cable entries, tapped M16 x 1.5 for ISO cable glands Ø : 4 elongated holes Ø 4.3 x 8.3 on 22/42 centres, 4 holes Ø 4.3 on 20/40 ctrs.
24 Te
1314 22
21
1211
2221
1314 24
23
2221
1413
1314 22
21
Limit switchesDouble insulated, CENELEC EN 50047 compatible (1), type XCK-TComplete switches with 2 cable entries, tapped M16 x 1.5
References, characteristics
Type of operating head Rotary Multi-directional
Type of Thermoplastic Variable length Square rod Round rod “Cat’s whisker”operator roller lever (2) thermoplastic u 3 mm Ø 3 mm
roller lever (3) steel (3) glass fibre (3)(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3) Adjustable throughout 360° in 5° steps.
References ( N/C contact with positive opening operation)