LIGHT INDUSTRIAL TANKS ULC-S601, ULC-S602, ULC-S652 BUILT TOUGH TO HANDLE ANY JOB YEARS W A R R A N T Y 10 S E E W A R R A N T Y C E R T I F I C A T UP TO GRANBYINDUSTRIES.COM Tough and durable, our light industrial tanks will meet your various storage requirements
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
• The double wall interstice is factory shipped under vacuum for constant monitoring of both walls’ integrity
• Equipped with a vacuum gauge for visual monitoring of leaks in the interstitial space
• High quality emergency vent
• 8 openings on top
• Integral spill box containment in accordance to ULC-S663
• Available hot dipped galvanized steel ladder and fill platform, on-site installation required
• Available hot dipped galvanized steel staircase and fill platform. The staircase can be mounted on the right, the left or in center of the fill platform without any additional cost and component; on-site installation required
• Mounting brackets for addition of pump, dispenser, hose retriever and emergency stop on opposite end of the ladder or staircase
• Optional vacuum loss switch
• Steel surface sandblasted and coated with Granby’s white polyurethane paint
Shown: 9 176 L + ladder
Shown: 9 176 L + stairs
STATIONARY TANKS - GENERAL SPECIFICATIONS
• ASTM A 1011 Steel• NPT female threaded openings• Capacity ranging from
125 to 2000 Gallons
• Double wall tanks• Each tank is manufactured and
controlled, tested and labeled in accordance with ULC-S601 standard for flammable and combustible liquids
For more information, please contact the head office98, rue des Industries Cowansville (Quebec) J2K 0A1 Canada@ [email protected] granbyindustries.com
* Contact your representative for more information on the different additional accessories available.
TANK CAPACITY AND DIMENSIONSGranby Storage Tanks offers light industrial tanks of different capacities for the storage of fuel, diesel, kerosene, lubricating oil and used oil. Tank weight vary according to the chosen model and options. Refer to the table below or to our website for further details.
DOUBLE WALL HORIZONTAL FOR FUEL OIL AND LUBRIFICATING OILCLOSED SECONDARY CONTAINMENT TANK, ULC-S602 LISTED
Capacity Dimensions Weight
PART LITERS GAL DIA LENGTH GAUGE POUNDS KG
3002C222NCAA 227 50 23” 40” 2.5mm 199 90
3006C222NCAA 570 125 30.5” 49” 2.5mm 341 155
3011C222NCAA 1135 250 38.5” 60” 2.5mm 531 241
3014C222NCAA 1360 300 50.5” 72” 2.5mm 601 273
3020C232NCAA 1915 420 50.5” 60” 2.5mm 774 352
3023C242NCAA 2275 500 50.5” 72” 2.5mm 867 394
DOUBLE WALL OBROUND TANKS, VACUUM MONITOREDPHOSPHATE CLEANED MODELS WITH WHITE POLYURETHANE PAINT, ULC-S602 LISTED
Capacity Capacity Dimensions Weight
PART LITERS GAL HEIGHT WIDTH LENGTH GAUGE POUNDS KG IMP GAL
125F22NCAA 1200 264 48” 28” 75” 2.5mm 626 285 264
124F22NCAA 1000 220 48” 28” 63” 2.5mm 547 249 220
127F22NCAA 830 182 48” 28” 52” 2.5mm 478 217 182
DOUBLE WALL STATIONNARY FOR USED OIL, VACUUM MONITOREDSANDBLASTED MODELS WITH WHITE SUPERIOR POLYURETHANE 10PLUS PAINT, ULC-S-652 LISTED