Brazil Egypt Norway Singapore United Kingdom United States West Africa Section 11 Lifting Slings BS EN 13414 January 15 BS EN 13414-1:2003 (E) Table 3 - Working load limits for slings using fibre cored rope of classes 6 x 19 and 6 x 36 in grade 1770 and having ferrule-secured eye terminations. to the vertical 0° 0° - 45° ›45° - 60° 0° - 45° ›45° - 60° 0° Direct Direct Direct Direct Direct Choke Hitch Rope dia Working Load Limits (WLL) mm t t t t t t 8 0.70 0.95 0.70 1.50 1.05 1.10 9 0.85 1.20 0.85 1.80 1.30 1.40 10 1.05 1.50 1.05 2.25 1.60 1.70 11 1.30 1.80 1.30 2.70 1.95 2.12 12 1.55 2.12 1.55 3.30 2.30 2.50 13 1.80 2.50 1.80 3.85 2.70 2.90 14 2.12 3.00 2.12 4.35 3.15 3.30 16 2.70 3.85 2.70 5.65 4.20 4.35 18 3.40 4.80 3.40 7.20 5.20 5.65 20 4.35 6.00 4.35 9.00 6.50 6.90 22 5.20 7.20 5.20 11.0 7.80 8.40 24 6.30 8.80 6.30 13.5 9.40 10.0 26 7.20 10.0 7.20 15.0 11.0 11.8 28 8.40 11.8 8.40 18.0 12.5 13.5 32 11.0 15.0 11.0 23.5 16.5 18.0 36 14.0 19.0 14.0 29.0 21.0 22.5 40 17.0 23.5 17.0 36.0 26.0 28.0 44 21.0 29.0 21.0 44.0 31.5 33.5 48 25.0 35.0 25.0 52.0 37.0 40.0 52 29.0 40.0 29.0 62.0 44.0 47.0 56 33.5 47.0 33.5 71.0 50.0 54.0 60 39.0 54.0 39.0 81.0 58.0 63.0 Leg Factor K L 1 1.4 1 2.1 1.5 1.6 One Leg Sling Two Leg Sling Three and Four Leg Sling Endless Sling 90 o Angle NOTE: The working load limits (WLLs) given in Table 3 are based on the assumption that soft eyes of single-leg slings are used over bearing points having diameters not less than twice the nominal diameter of the rope. Table 3 shows working load limit values for ferrule-secured eye slings in various configurations. Nominal
11
Embed
Lifting Slings BS EN 13414Lifting Slings BS EN 13414 January 15 BS EN 13414-1:2003 (E) Table G.5 - Working load limits for cable-laid slings made of wire ropes with steel core of classes
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Section 11
Lifting Slings BS EN 13414
January 15
BS EN 13414-1:2003 (E)
Table 3 - Working load limits for slings using fibre cored rope of classes 6 x 19 and 6 x 36 in grade 1770 and having ferrule-secured eye terminations.
to the vertical 0° 0° - 45° ›45° - 60° 0° - 45° ›45° - 60° 0°
One Leg Sling Two Leg Sling Three and Four Leg Sling Endless Sling
90o
Angle
NOTE: The working load limits (WLLs) given in Table 3 are based on the assumption that soft eyes of single-leg slings are used over bearing points having diameters not less than twice the nominal diameter of the rope.
Table 3 shows working load limit values for ferrule-secured eye slings in various configurations.
Nominal
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Lifting Slings BS EN 13414
Section 11
January 15
BS EN 13414-1:2003 (E)
Table 4 - Working load limits for slings using steel cored rope of classes 6 x 19, 6 x 36 and 8 x 36 in grade 1770 and having ferrule-secured eye terminations.
to the vertical 0° 0° - 45° ›45° - 60° 0° - 45° ›45° - 60° 0°
One Leg Sling Two Leg Sling Three and Four Leg Sling Endless SlingAngle
NOTE: The working load limits (WLLs) given in Table 4 are based on the assumption that soft eyes of single-leg slings are used over bearing points having diameters not less than twice the nominal diameter of the rope.
Table 4 shows working load limit values for ferrule-secured eye slings in various configurations.
Nominal
90o
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Section 11
Lifting Slings BS EN 13414
Endless Sling (Grommet)
Angle to the vertical 0° 0°
Direct Choke Hitch
Working Load Limits (WLL)
Rope Diameter mm t t
24 9.00 7.00
27 11.5 9.00
30 14.0 11.0
33 17.0 13.5
36 20.0 16.0
39 23.5 19.0
42 27.0 21.5
48 35.5 28.5
54 45.0 36.0
60 55.5 44.5
Calculation Factors 2 1.6
BS EN 13414-3:2003 (E)
Table G.1 - Working load limits for cable-laid endless slings (grommets) made of wire ropes with steel core of classes 6 x 19 and 6 x 36.
January 15
Nominal
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Lifting Slings BS EN 13414
Section 11
Endless Sling (Grommet)
Angle to the vertical 0° 0°
Direct Choke Hitch
Working Load Limits (WLL)
Rope Diameter mm t t
66 69.0 55.0
72 84.0 68.0
78 102 81.0
84 121 97.0
90 144 115
96 168 135
102 196 157
108 227 182
114 262 210
120 300 240
126 344 275
132 392 314
144 505 404
Calculation Factors 2 1.6
BS EN 13414-3:2003 (E)
Table G.2 - Working load limits for cable-laid endless slings (grommets) made of wire ropes with steel core of classes 6 x 36.
January 15
Nominal
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Section 11
Lifting Slings BS EN 13414
January 15
BS EN 13414-3:2003 (E)
Table G.3 - Working load limits for cable-laid endless slings (grommets) made of wire ropes with steel core of classes 6 x 36.
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Lifting Slings BS EN 13414
Section 11
Endless Sling (Grommet)
Angle to the vertical 0° 0°
Direct Choke Hitch
Working Load Limits (WLL)
Rope Diameter mm t t
24 8.25 6.50
27 10.5 8.5
30 11.5 9.00
33 14.0 11.0
36 16.5 13.0
39 19.5 15.5
42 22.5 18.0
48 30.0 23.5
54 37.5 30.0
60 46.0 37.0
Calculation Factors 2 1.6
BS EN 13414-3:2003 (E)
Table G.4 - Working load limits for cable-laid endless slings (grommets) made of wire ropes with FIBRE core of classes 6 x 19 and 6 x 36.
January 15
Nominal
Brazil Egypt Norway Singapore United Kingdom United States West Africa
Section 11
Lifting Slings BS EN 13414
January 15
BS EN 13414-1:2003 (E)
Table G.5 - Working load limits for cable-laid slings made of wire ropes with steel core of classes 6 x 19 and 6 x 36 with ferrule-secured eye terminations.
to the vertical 0° 0° up to 45° 0° 0° up to 45° 0° 0°