Life Pack 12 Life Pack 12 Biphasic technology. Biphasic technology. Compatible with QUIK-COMBO™ Compatible with QUIK-COMBO™ pacing/ defibrillation/ pacing/ defibrillation/ ECG electrodes. ECG electrodes.
Life Pack 12Life Pack 12
Biphasic technology. Biphasic technology.
Compatible with QUIK-COMBO™ Compatible with QUIK-COMBO™ pacing/ defibrillation/pacing/ defibrillation/
ECG electrodes. ECG electrodes.
Life Pack 12Life Pack 12What can it do?What can it do?
ECG MONITORINGECG MONITORING
ACQUIRING A 12-LEAD ECGACQUIRING A 12-LEAD ECG
PULSE OXIMETRYPULSE OXIMETRY
AUTOMATED EXTERNAL DEFIBRILLATIONAUTOMATED EXTERNAL DEFIBRILLATION
MANUAL DEFIBRILLATIONMANUAL DEFIBRILLATION
SYNCHRONIZED CARDIOVERSIONSYNCHRONIZED CARDIOVERSION
NONINVASIVE PACINGNONINVASIVE PACING
NIBP MONITORINGNIBP MONITORING
THERAPY WARNINGSTHERAPY WARNINGS
CONTROLS AND INDICATORS
MO-1 DMAT
Controls and Indicators - Area 1 ON Button: Switches power on / off
Energy Select: Selects energy levels in manual shock. Press the up or down button.
Charge: When the defibrillator is
charging a charging bar appears and a ramping tone sounds.
Shock: Discharges the shock to the patient. If shock is not delivered in 60 sec, the stored energy is removed. If you change the charge energy, the energy is removed and you will need to recharge.
Sync: Use for cardioversion.
MO-1 DMAT
Controls and Indicators - Area 1 Battery Charge: Indicates that at
least one battery is installed and being charged by an AC/DC power adapter
Service: Indicates that the internal self-check failed
Advisory: Activates continuous patient surveillance system (CPSS) which monitors the patient for potential shockable rhythm
Analyze: Activates the Shock Advisory
System (SAS). SAS is a ECG analysis system that will advise the user if it detects a shockable or nonshockable rhythm
Controls and Indicators - Area 2
Pacer: Switches pacer on and off indicated by light. Once the ECG confirm a triangle sensor marker on the top of the QRS, if not change leads or adjust.
Rate: Press the button (10ppm) or rotate the dial (5ppm)to the desired rate
Current: Press the button for 10 increments or rotate the dial for 5 increments until capture occurs. Pacer indicator will flash with each pacing stimulus.
Pause: Push and hold this button to pause pacing. Pacing will continue at 25% of set rate. Release button and pacing will continue at set rate
Controls and Indicators - Area 3
Lead: Select or change ECG leads. Press the lead button again or rotate the dial to the desired lead. Display will be on the right side of the screen.
Size: Press the button a display will appear. Either press again or rotate the dial to the desired ECG size.
NIBP: Press the button to activate. Cuff should inflate 30mmHg higher then pt systolic pressure.
Alarms: Can be configured on or off. Alarms are set to a predetermined limits. They can be adjusted.
Controls and Indicators – Area 3
Options: Press the button and a screen will display Patient, Pacing, Date/Time, Alarm volume, Archives, Print and User Test.
Events: Press the event button and scroll thru the screen selecting the choice from Adenosine, ASA, Atropine, Bicarb, CPR, Dopamine, Epinephrine, Intubation for example. By pressing the button a timestamp will appear on the code summary.
Home Screen: Pressing this button will return you to from any overlay screen to the home screen EXCEPT during AED analysis or manual defibrillation charging or shocking.
Controls and Indicators - Area 4
CO2 tubing connector: Open the connection door and connect the Capnography tubing next connect to the patient.
SPO2 Cable Connector: When plugged in performs a 17 sec calibration and 3 sec self test. Measures SpO2 between 50% and 100%.
NIBP Tubing Connector: When connect there is a 3 sec self test. Typically takes pressure within 40 sec. but no longer 120 sec.
ECG Cable Connector: Connect the trunk lead and the limb leads and/or the 12 leads are connected the trunk lead.
MO-1 DMAT
Controls and Indicators - Area 4
Speaker
Printer
Therapy Cable Connector: Connect cable to therapy electrodes or to the paddles.
Controls and Indicators - Area 5
12 Lead: Press to initiate acquisition of a
12 lead ECG.
Transmit: Capability to transmit patient data.
Code Summary: Pressing button will print the code summary with critical events that were recorded.
Print: Press the button to start and to stop the printer.
MO-1 DMAT
Controls and Indicators - Area 6
ECG MONITORINGECG MONITORING
ECG Monitoring - Patient ECG cable
ECG Monitoring – Combo Electrode
Selecting ECG leas and size
Adjusting systole volume
Alarm settings
SpO2 MONITORINGSpO2 MONITORING
Adjust Sensitivity normal/highAdjust Sensitivity normal/high
Average Sensing time 4,8,12 and 16 SecAverage Sensing time 4,8,12 and 16 Sec
Hi light and select SpO2 volumeHi light and select SpO2 volume
Cover sensor if excessive ambient light presentCover sensor if excessive ambient light present
SpO2 waveform displays on channel 2SpO2 waveform displays on channel 2
AUTOMATED EXTERNAL DEFIBRILLATIONAUTOMATED EXTERNAL DEFIBRILLATION
AED – Do not place electrodes in AED – Do not place electrodes in Anterior and posteriorAnterior and posterior
AED – Not for Pediatric less than AED – Not for Pediatric less than 8Yrs8Yrs
Press Advisory – (CPSS On)Press Advisory – (CPSS On)
Press Analyze – (SAS On)Press Analyze – (SAS On)
AED – Motion detector Auto onAED – Motion detector Auto on
AED SAMPLE VIDEOAED SAMPLE VIDEO
AED SAMPLE VIDEO.MSWMM
MANUAL DEFIBRILLATIONMANUAL DEFIBRILLATION
Press Energy Select or Rotate Press Energy Select or Rotate energy select dialenergy select dial
Press charge – Press shockPress charge – Press shock
Shock not pressed in 60sec. Auto Shock not pressed in 60sec. Auto
discharge internallydischarge internally
SYNCHRONIZED CARDIOVERSIONSYNCHRONIZED CARDIOVERSION
ECG through Therapy Electrode, Select ECG through Therapy Electrode, Select PaddlesPaddles
Press sync – LED blinks each QRSPress sync – LED blinks each QRS
Confirm triangle sense markerConfirm triangle sense marker
Press Energy Select or Rotate energy Press Energy Select or Rotate energy select dialselect dial
Press charge – Confirm ECG rhythm and Press charge – Confirm ECG rhythm and available energyavailable energy
Press and hold shock button until Press and hold shock button until discharge occurs with next QRS complexdischarge occurs with next QRS complex
NONINVASIVE PACINGNONINVASIVE PACING
Demand and Nondemand PacingDemand and Nondemand Pacing
Place ECG and Therapy electrodesPlace ECG and Therapy electrodes
Press pacer. Confirm LED illuminatesPress pacer. Confirm LED illuminates
Press rate or rotate selector set PPMPress rate or rotate selector set PPM
Press current or rotate selector – electrical Press current or rotate selector – electrical capture occurredcapture occurred
View intrinsic rhythm press and hold pass.View intrinsic rhythm press and hold pass.(25%)(25%)
NONINVASIVE BLOOD PRESSURENONINVASIVE BLOOD PRESSURE
Initial Inflation pressureInitial Inflation pressure
Manual single measurementManual single measurement Timer controlled measurementTimer controlled measurement
Pulse not displayed when spo2 / ECG activePulse not displayed when spo2 / ECG active
THERAPY WARNINGSTHERAPY WARNINGS Do not clean with ketones or other flammable agents. Do not clean with ketones or other flammable agents.
Do not autoclave or sterilize this device accessoriesDo not autoclave or sterilize this device accessories
Do not use this device in the presence of flammable Do not use this device in the presence of flammable gases or anesthetics. Use care when operating this gases or anesthetics. Use care when operating this device close to oxygen sources (such as bag-valve-device close to oxygen sources (such as bag-valve-mask devices or ventilator tubing). Turn off gas mask devices or ventilator tubing). Turn off gas source or move source away from patient during source or move source away from patient during defibrillation.defibrillation.
Avoid operating device near cauterizers, diathermy Avoid operating device near cauterizers, diathermy equipment, or cellular phones. Maintain equipment equipment, or cellular phones. Maintain equipment separation of at least 1.2 mtrs.separation of at least 1.2 mtrs.
CODE SUMMARY REPORTCODE SUMMARY REPORT
THANK YOUTHANK YOU