Top Banner
Centennial Lidsdale Siding Environmental Monitoring Data June 2018
11

Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Aug 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Centennial Lidsdale Siding

Environmental Monitoring Data

June 2018

Page 2: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

TABLE OF CONTENTS

INTRODUCTION ................................................................................................................................. 1

1. WEATHER ................................................................................................................................. 2

2. AIR QUALITY MONITORING .................................................................................................... 2

2.1 Depositional Dust ..................................................................................................................... 2

2.2 PM10 Monitoring ...................................................................................................................... 4

3. SURFACE WATER MONITORING ............................................................................................ 4

4. NOISE MONITORING ................................................................................................................ 5

5. INCIDENTS ................................................................................................................................ 5

6. COMPLAINTS ........................................................................................................................... 5

7. CORRECTIONS LOG ................................................................................................................ 5

TABLES

Table 1 – Licence Information ............................................................................................................... 1

Table 2 –Supporting Information for Monitoring Points ...................................................................... 1

Table 3 – Weather Summary .................................................................................................................. 2

Table 4 – Depositional Dust ................................................................................................................... 2

Table 5 – LDP004 Sampling Results ..................................................................................................... 4

Table 6 – Corrections log for LSDG8 .................................................................................................... 5

Table 7 – Corrections log for LSDG11 .................................................................................................. 6

FIGURES

Figure 1 – Summary of July 2017-June 2018 depositional dust .......................................................... 3

Figure 2 – Depositional Dust 12-month rolling average July 2017- June 2018 .................................. 3

Figure 3 – Lidsdale Siding BAM 24hr average for this reporting period ............................................ 4

APPENDIX 1 – Air Quality Monitoring Locations

Page 3: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

INTRODUCTION

As per conditions M1 to M6 of EPL 5129, this report summarises environmental monitoring results for Lidsdale Siding Coal Loading Facility (Lidsdale Siding) for the June 2018 period. Monitoring sites are shown in Appendix 1. A summary of the licence information is provided below.

Table 1 – Licence Information

Environment Protection Licence number

5129

Licensee’s Name Ivanhoe Coal Pty Ltd

Licensee’s Address Level 18, BT Tower, 1 Market Street Sydney NSW 2000

EPL Location http://www.epa.nsw.gov.au/prpoeoapp/ViewPOEOLicence.aspx?DOCID=34652&SYSUID=1&LICID=5129

Table 2 –Supporting Information for Monitoring Points

Parameter Monitoring Frequency

Unit of Measure

June 2018

Sampling Date Publishing Date

Depositional Dust LSDG1 (Point 5) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG6 (Point 2) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG7 (Point 1) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG8 (Point 3) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG9 (Point 6) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG10 (Point 7) Monthly g/m2/month 01/06/2018 20/07/2018

Depositional Dust LSDG11 Monthly g/m2/month 01/06/2018 20/07/2018

PM10 (Point 8) Continuous µg/m³ 01/06/2018 – 30/06/2018

20/07/2018

LDP004 (Point 4) Oil & Grease Monthly during

discharge mg/L - 20/07/2018

LDP004 (Point 4) pH Monthly during

discharge pH units - 20/07/2018

LDP004 (Point 4) Total Suspended Solids

Monthly during discharge

mg/L - 20/07/2018

LDP004 (Point 4) Conductivity Monthly during

discharge µS/cm - 20/07/2018

Page 4: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

1. WEATHER A summary of weather data recorded during the reporting period is shown in Table 3.

Table 3 – Weather Summary

June 2018 Temperature Rainfall (mm)

Minimum (daily)

-4.26 0.00

Maximum (daily)

9.07 15.8

Total - 31.6

2. AIR QUALITY MONITORING The air quality monitoring results for the reporting period are summarised below.

2.1 Depositional Dust The depositional dust (g/m2/month) results (insoluble solids) for the reporting period are shown in Table 4 and Figure 1.

Table 4 – Depositional Dust

Site June

LS Dust Gauge 1 (Point 5) 0.3

LS Dust Gauge 6 (Point 2) 1.5

LS Dust Gauge 7 (Point 1) 0.8

LS Dust Gauge 8 (Point 3) 3.2

LS Dust Gauge 9 (Point 6) 1.3

LS Dust Gauge 10 (Point 7) 0.6

LS Dust Gauge 11 1.0

EPL 5129 does not include a licence limit for depositional dust. A 12-month rolling average air quality

criteria of 4 g/m2/month is commonly used for comparison purposes (Figure 2). The 4 g/m2/month criteria

is a condition of the Lidsdale Siding project approval, however applies at residences on privately owned

property. The Lidsdale Siding dust gauges are located near operational areas, and not at private

residences.

Page 5: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

Figure 1 – Summary of July 2017-June 2018 depositional dust

Figure 2 – Depositional Dust 12-month rolling average July 2017- June 2018

0

2

4

6

8

10

12

Jul-17 Aug-17 Sep-17 Oct-17 Nov-17 Dec-17 Jan-18 Feb-18 Mar-18 Apr-18 May-18 Jun-18

Inso

lub

le S

olid

s (g

/m2

/mo

nth

)

Lidsdale Siding depositional dust

LSDG1 LSDG6

LSDG7 LSDG8

LSDG9 LSDG10

LSDG11 Annual Average Limit (4g/m2/month)

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Jul-17 Aug-17 Sep-17 Oct-17 Nov-17 Dec-17 Jan-18 Feb-18 Mar-18 Apr-18 May-18 Jun-18

g/m

2 /m

on

th

Depositional Dust 12-month rolling average

LSDG1 LSDG6 LSDG7 LSDG8

LSDG9 LSDG10 LSDG11 12mth maximum

Page 6: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

2.2 PM10 Monitoring The short-term criterion for particulate matter of 50 μg/m3 was not exceeded for the month. The gap in data for the period 9 June to 13 June is attributed to a battery failure in the particulate matter mass monitor.

Figure 3 – Lidsdale Siding BAM 24hr average for this reporting period

3. SURFACE WATER MONITORING Surface water pH, Total Suspended Solids, Conductivity and Oil & Grease are monitored at LDP004 during discharges. There was no discharge through LDP004 during June 2018.

Table 5 – LDP004 Sampling Results

Parameter Unit of

Measure Result Limit Exceedance

pH pH units ND 6.5-8.5 No

Total Suspended Solids mg/L ND 30 No

Electrical Conductivity µS/cm ND # No

Oil & Grease mg/L ND 10 No

# no concentration limit, ND = Nil discharge

0

10

20

30

40

50

60

Du

st M

ass

(µg/

m³)

24 Hour Average Dust Mass June 2018

Mass Concentration (µg/m³) 24 hour criterion

Page 7: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

4. NOISE MONITORING Environmental noise monitoring described in this report was undertaken during the day, evening and night periods on 7 and 8 June 2018. Activities from Lidsdale Siding complied with the relevant development consent noise limits during attended noise monitoring for June 2018 at all monitoring locations.

5. INCIDENTS No environmental incidents were recorded at Lidsdale Siding during the June 2018 reporting period.

6. COMPLAINTS No complaints were recorded during the June 2018 reporting period.

7. CORRECTIONS LOG

Ivanhoe Coal Pty Ltd

EPL No. 5129

Sample Point: LSDG8

Instrument: Dust deposition stand with gauge

Pollutant: Depositional dust

Table 6 – Corrections log for LSDG8

Sample

date and

time

Original

data

(g/m2/month)

Corrected

data

(g/m2/month)

Date

corrected

Date

originally

published

Reason

01/11/2017 32.9 6.58 28/11/2017 14/12/2017 Examination of dust fallout gauge

deposit by stereomicroscopy and

scanning electron microscopy revealed

20% particle type attributable to

Lidsdale Siding operations

02/01/2018 18.5 11.1 08/02/2018 12/02/2018 Examination of dust fallout gauge

deposit by stereomicroscopy and

scanning electron microscopy revealed

60% particle type attributable to

Lidsdale Siding operations

01/02/2018 9.5 2.85 10/05/2018 14/03/2018 Examination of dust fallout gauge

deposit by stereomicroscopy and

scanning electron microscopy revealed

30% particle type attributable to

Lidsdale Siding operations

Page 8: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

Sample Point: LSDG11

Instrument: Dust deposition stand with gauge

Pollutant: Depositional dust

Table 7 – Corrections log for LSDG11

Sample

date and

time

Original

data

(g/m2/month)

Corrected

data

(g/m2/month)

Date

corrected

Date

originally

published

Reason

01/03/2018 7.5 0.15 04/04/2018 12/04/2018 Examination of dust fallout gauge

deposit by stereomicroscopy and

scanning electron microscopy revealed

2% particle type attributable to Lidsdale

Siding operations

Page 9: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

APPENDIX 1

SITE MONITORING LOCATIONS

Page 10: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding

Page 11: Lidsdale Siding Environmental Monitoring Report January ... · A 12-month rolling average air quality criteria of 4 g/m2/month is commonly used for comparison purposes 2(Figure 2).

Environmental Monitoring Results Summary – Centennial Lidsdale Siding