This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
LG COMMERCIALAIR CONDITIONERS 2011Vitalizing You & Your Environment
VItaLIzInG You & Your EnVIronmEnt"LG AC company is the only brand that provides comprehensive solutions to vitalize you and your business at less cost of the natural environment"
03 03 /04
Vitalizing you & your environment
Air Conditioning with LG
07 Line up
13 Ceiling Cassette
09 Ceiling Concealed Duct
35
41
51
55
Ceiling & Floor /Ceiling Suspended
Floor Standing
Single Packaged
Ducted Split
2011 Model Line-up
Btu/h 9 12 18 24 28 30 36 42 48 54 60 72 96
12
18 24 28 30 36 48 54
9 12 18 24 30 36 42 48 60
18 24 30 36 42 48 60
72 96
12 18 24
30 36 48 60
18 24
30 36 48 60
Ceiling C
assette TypeC
eiling and Floor TypeC
eiling Concealed
D
uct Type
Btu/h 9 12 18 24 28 30 36 42 48 54 60 72 96
Ducted S
plitFloor S
tandingS
ingle P
ackaged
28
24
30
48
96
3 RT
3,4,5 RT
5 RT4 RT
7.5,10 RT
High Static
High Static
Low Static
07 07 /08
Ceiling C
assetteC
eiling Concealed
Duct
Ceiling &
Floor /C
eiling Susp
ended
Ducted
Sp
litS
ingle Packaged
Floor Stand
ing
LG Air Conditioners 2011
PLASMA Air Purifying System (Optional)
The PLASMA Air Purifying System, developed uniquely by LG, not only removes microscopic contaminants and dust, but also eliminates house mites, pollen and pet hair, to prevent allergic diseases, like asthma. With a filter that can be cleaned by simply washing it with water, and used over and over again, you can enjoy clean, fresh air without the cost of regular filter changes.
Two Thermistor(Unit Body and Remote Controller)
Group Control
There may be a significant difference between thetemperature taken at the installed product and indoortemperature. Dual thermistor control provides option tocontrol temperature by referring any of the two temperatures. With the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote.
It enables to control up to 16 units with the help of one wired remote controller. All the units will follow same setting of temperature & other sub functions.
CEILING CASSETTE
Clean Air
Polluted Air
Cover
Photo-CatalystCoated Mesh
Plasma ionizerRating Voltage=4.8kV
Case
Powerinput terminal
Swirl SwingEven cooling down to the floor by Swirl Swing
4-Open (Conventional)
2.4% 4.8%100% Improved
Swirl Swing (New)
LG “Ceiling Cassette “ is used for the multi-functional purpose. It can be installed in Various placed such as restaurants, hotels, offices and luxury residential. This unit has Nice outlook and is equipped with many special features. It has four vanes for the air Circulation in all directions which in turn can maintain even and wide cooling and heating. It makes your life fresh and comfortable with economic advantage.
CEILING CASSETTE
09 09 /10
Ceiling C
assetteC
eiling Concealed
Duct
Ceiling &
Floor /C
eiling Susp
ended
Ducted
Sp
litS
ingle Packaged
Floor Stand
ing
LG Air Conditioners 2011
Long Distance(50m) High Elevation(30m)
High Ceiling Operation
Fast Cooling
LG Air Conditioners (Cassette and Duct-type models) can be installed at long distances (max 50m) and high height differences (30m) from the outdoor unit.
According to the ceiling height, the speed of the internal fan can be adjusted with a sliding switch on the back of the wired remote control unit.
Jet Cool Function is quick cooling. In this mode, strong and cool air is blown at highest speed to cool down the room temperature targeting to reach 18ºC.
Wireless Remote Controller(Optional)
Auto Restart Function
Simple and sophisticated operations.
In case of a sudden power failure, this feature willautomatically restore the A/C to its previous settings when power returns.
50m 30m
Quick and Easy to InstallationCompact body ensure space saving installation
Refrigerant Piping
Capacity18k~30k36k~48k
H (mm)225288
High Head Drain PumpAuxiliary Drain Pump automatically drains water. A standard drain-head height of up to 700mm is possible, creating the ideal solution for perfect water drainage.
Flexible Drain Hose
Drain pipeFixture
Drain Pipe Slope (1/50~1/100)
700mm
450mm
300mm
(Accessory:ABDPG)
12k
Specifications
• LT-C1260CL• LT-C1260hL
CEILING CASSETTE
Power Failure
Setting stored beforepower failure.
Power Resume
Auto Restart System
Operation Stop
E2 Prom
Restart
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions Body mm
(WxHxD) Decoration panel mm
Net Weight Body kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions(WxHxD) Body mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
F/Panel
1/220-240/50
3.52
12,000
-
-
1,200
-
10.00
-5.5
-
10/9/8
353/317/283
38/35/32
1.5
860x390x180
1,050x480x30
22
5.5
-
Rotary
R22
800
46
770x540x245
31
6.35
12.7
- /Ø25
15
7
1/220-240/50
3.52
12,000
3.52
12,000
1,200
1,100
10.00
10.91
5.5
5
10/9/8
353/317/283
38/35/32
1.5
860x390x180
1,050x480x30
22
5.5
5
Rotary
R22
850
46
770x540x245
31
6.35
12.7
Ø32/Ø25
15
7
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions Body mm
(WxHxD) Decoration panel mm
Net Weight Body kg
Decoration panel kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions(WxHxD) Body mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Ind
oo
r U
nit
Out
do
or
Uni
t
Out
do
or
Uni
t
F/PanelF/Panel
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification. Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
PT-CDA1 / PT-CDC1
3/380-415 /50
10.5
35,830
-
-
4.0
-
8.96
-
0.4
-
24/21/19
848/742/671
41/38/35
3
840x840x288
950x950x30
31
5
7.0
-
Scroll
R22
2,450
60
870x1,060x320
88
6.35
15.88
32/25
50
30
LT-C368DLE1PT-CCA / PT-CEC1
1/220-240/50
5.27
18,000
-
-1.95
-
9.23
-
0.3
-
11/10/9
388/353/317
41/39/37
2.4
570x570x269
650x650x30
19
3
10
-
Rotary(tropical)
R22
1,200
41
840x575x275
51
6.35
12.7
32/25
30
20
LT-C186ELE1PT-HDA1 / PT-HDC1
3/380-415/50
10.5
35,830
11.2
38,220
4.0
4.0
8.96
9.56
0.4
-
24/21/19
848/742/671
41/38/35
3
840x840x288
950x950x30
31
5
7.0
7.0
Scroll
R22
2,450
60
870x1,060x320
88
6.35
15.88
32/25
50
30
LT-H368DLE1PT-HEA1 / PT-HEC1
1/220-240/50
5.27
18,000
5.53
18,900
1.95
1.95
9.23
9.69
0.3
-
11/10/9
388/353/317
41/39/37
2.4
570x570x269
650x650x30
19
3
10
10
Rotary(tropical)
R22
1,200
55
840x575x275
51
6.35
12.7
32/25
30
20
LT-H186ELE1PT-CDA1 / PT-CDC1
3/ 380-415/50
14
47,770
-
-
4.9
-
9.75
-
0.4
-
31/29/27
1,094/1,024/953
45/44/42
6.3
840x840x288
950x950x30
31
5
8.5
-
Scroll
R22
3,700
59
900x1,160x370
105
9.52
19.05
32/25
50
30
LT-C488DLE1PT-CDA1 / PT-CDC1
1/220-240/50
7.0
23,885
-
-
2.67
-
8.95
-
0.3
-
17/15/13
600/530/460
36/33/30
2.4
840x840x225
950x950x30
27
5
2.67
-
Rotary(tropical)
R22
1,650
56
870x655x320
64
6.35
15.88
32/25
50
30
LT-C246HLE1PT-HDA1 / PT-HDC1
3/380-415/50
14
47,770
15.2
51,865
4.9
5.3
9.75
9.79
0.4
-
31/29/27
1,094/1,024/953
45/44/42
6.3
840x840x288
950x950x30
31
5
8.5
8.7
Scroll
R22
3,700
59
900x1,060x370
105
9.52
19.05
32/25
50
30
LT-H488DLE1PT-HDA1 / PT-HDC1
1/220~240/50
7.0
23,885
7.0
23,885
2.67
2.45
8.95
9.75
0.3
-
17 / 15 / 13
600/530/460
36 / 33 / 30
2.4
840x840x225
950x950x30
27
5
12.5
11.5
Rotary(tropical)
R22
1,650
56
870x655x320
64
6.35
15.88
32 / 25
50
30
LT-H246HLE1PT-CDA1 / PT-CDC1
3/380-415 /50
15.82
54,000
-
-
5.6
-
9.64
-
0.4
-
37/35/31
1,300/1,240/1,090
48/46/44
6.3
840x840x288
950x950x30
31
5
10.0
-
Scroll
R22
3,750
58
900x1,160x370
105
9.52
19.05
32/25
50
30
LT-C548DLE2PT-CDA1 / PT-CDC1
1/220-240/50
8.2
27,982
-
-
2.9
-
9.65
-
0.3
-
20/17/14
706/600/494
38/33/30
2.4
840x840x225
950x950x30
28.5
5
2.9
-
Twin Rotary(tropical)
R22
2,250
58
870x808x320
68
6.35
15.88
32/25
50
30
LT-C286HLE1PT-HDA1 / PT-HDC1
3/380-415/50
15.82
54,000
17.29
59,000
5.6
6.6
9.64
8.94
0.4
-
37/35/31
1,300/1,240/1,090
48/46/44
6.3
840x840x288
950x950x30
31
5
10.0
11.5
Scroll
R22
3,750
58
900x1,060x370
105
9.52
19.05
32/25
50
30
LT-H548DLE2PT-HDA1 / PT-HDC1
1/220-240/50
8.2
27,982
8.8
30,030
2.9
2.9
9.65
10.36
0.3
-
20/17/14
706/600/494
38/33/30
2.4
840x840x225
950x950x30
28.5
5
13.7
13.7
Twin Rotary(tropical)
R22
2,250
58
870x808x320
68
6.35
15.88
32/25
50
30
LT-H286HLE1
13 13 /14
Ceiling C
assetteC
eiling Concealed
Duct
Ceiling &
Floor /C
eiling Susp
ended
Ducted
Sp
litS
ingle Packaged
Floor Stand
ing
LG Air Conditioners 2011
• hT-C186hL*1• hT-C246hL*1
• hT-C306hL*0• hT-C368dL*1• hT-C488dL*1
CEILING CASSETTE CEILING CASSETTE
30k, 36k18k, 24k
Specifications Specifications
* A : Basic
* C : Plasma Air Purifying
* E : Elevation Grille
* F : Elevation Gille + Plasma Air Purifying
* A : Basic
* C : Plasma Air Purifying
* E : Elevation Grille
* F : Elevation Gille + Plasma Air Purifying
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions Body mm
(WxHxD) Decoration panel mm
Net Weight Body kg
Decoration panel kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions(WxHxD) Body mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions Body mm
(WxHxD) Decoration panel mm
Net Weight Body kg
Decoration panel kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions(WxHxD) Body mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Ind
oo
r U
nit
Out
do
or
Uni
t
Out
do
or
Uni
t
F/Panel F/PanelPT-CDA1
1/220-240/50
5.3
18,000
-
-
1.55
-
10.53
-
0.3
-
15/12/10
530/424/353
31/27/24
1.15
840x840x225
950x950x30
26
5
7.75
-
Rotary
R22
1,100
56
870×655×320
51
6.35
12.7
32/25
30
10
PT-CDA1
1/220-240/50
7.0
24,000
-
-
2.33
-
10.30
-
0.3
-
17/15/13
600/530/459
34/32/29
2.4
840x840x225
950x950x30
26
5
11.0
-
Rotary
R22
1,520
53
870×655×320
62
6.35
15.88
32 / 25
30
10
HT-C186HL*1PT-CDA1
1/220-240/50
8.8
30,000
-
-
3.05
-
9.84
-
0.3
-
22/20/18
777/706/636
42/40/37
3.4
840x840x225
950x950x30
26
5
15.0
-
Rotary
R22
2,000
54
870×800×320
73
6.35
15.88
32/25
30
10
HT-C306HL*0PT-CDA1
3/380-415/50
10.6
36, 000
-
-
3.93
-
9.16
-
0.4
-
27/21/20
954/742/706
44/39/38
3.8
840x840x288
950x950x30
33
5
7.0
-
Scroll
R22
2,100
54
870×800×320
79
6.35
15.88
32/25
50
15
HT-C368DL*1PT-CDA1
3/380-415/50
14.1
48,000
-
-
4.9
-
9.80
-
0.4
-
36/31/27
1,271/1,095/954
49/46/43
4.6
840x840x288
950x950x30
33
5
8.5
-
Scroll
R22
2,600
59
900×1,160×370
87
9.52
19.05
32/25
50
15
HT-C488DL*1HT-C246HL*1
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification. Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions Body mm
(WxHxD) Decoration panel mm
Net Weight Body kg
Decoration panel kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions(WxHxD) Body mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Ind
oo
r U
nit
Out
do
or
Uni
t
Out
do
or
Uni
t
F/Panel F/Panel PTPC-HLA0
1/220-240/50
5.2
17,742
-
-
1.86
-
9.54
-
9.5
-
15/13/11
530/459/388
38/36/34
1.5
840x840x225
950x950x30
26
9.5
-
Rotary
R22
1,100
54
801x555x262
42
6.35
15.88
Ø32 / Ø25
30
15
PTPC-HLA0
1/220-240/50
7.1
24,225
-
-
2.4
-
10.09
-
11.5
-
18/16/14
635/565/492
39/38/37
2.1
840x840x225
950x950x30
26
11.5
-
Rotary
R22
2,300
55
870x655x320
42
6.35
15.88
Ø32 / Ø25
30
15
PT-CDA1
1/220-240/50
5.3
18,000
-
-
1.55
-
11.61
-
0.3
-
15/12/10
530/424/353
31/27/24
1.15
840x840x225
950x950x30
26
5
7.75
-
Rotary
R22
1,100
56
870×655×320
51
6.35
12.7
32/25
30
15
HT-C186HL*2PT-CDA1
1/220-240/50
7.0
24,000
-
-
2.33
-
10.30
-
0.3
-
17/15/13
600/530/459
34/32/29
2.4
840x840x225
950x950x30
26
5
11.0
-
Rotary
R22
1,520
53
870×655×320
62
6.35
15.88
32/25
30
15
HT-C246HL*2PT-CDA1
1/220-240/50
8.8
30,000
-
-
3.05
-
9.52
-
0.3
-
22/20/18
777/706/636
42/40/37
3.4
840x840x225
950x950x30
26
5
15.0
-
Rotary
R22
2,000
54
870×800×320
73
6.35
15.88
32/25
50
15
HT-C306HL*1PT-CDA1
3/380-415/50
10.6
36,000
-
-
3.50
-
9.17
-
0.4
-
27/21/20
954/742/706
44/39/38
3.8
840x840x288
950x950x30
33
5
6.0
-
Scroll
R22
2,000
58
900×1,160×370
81
6.35
15.88
32/25
50
15
HT-C368DL*2 TT-C186HL*0 TT-C246HL*0
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification. Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
17 17 /18
Ceiling C
assetteC
eiling Concealed
Duct
Ceiling &
Floor /C
eiling Susp
ended
Ducted
Sp
litS
ingle Packaged
Floor Stand
ing
*E.S.P: External Static Pressure
Quiet Operation & Easy Service
High Head Drain Pump
The air volume and sound level is kept constant as designed regardless of changes in E.S.P.(External Static Pressure)
Phase control motor technology reduces installation costs. The desired air flow is obtained by adjusting the phase motor during installation of the product, giving you more flexibility when setting up your duct system. The E.S.P can be adjusted linearly from 0 to 10mmAq.
Auxiliary Drain Pump automatically drains water. A standard drain-head height of up to 700mm is possible, creating the ideal solution for perfect water drainage.
A lightweight plastic blower and housing makes air conditioning operation quiet and backup servicing more convenient. The new fan housing can be easily dismantled for convenient servicing and maintenance. The fan motor can be removed without the need to remove the complete fan direct assembly.
CEILING CONCEALED DUCT
Flexible Drain Hose
Drain pipeFixture
Drain Pipe Slope (1/50~1/100)
700mm
450mm
300mm
(Accessory:ABDPG)
Conventional LG Fan and Housing
LG Air Conditioners 2011
Zero power consumption use in standby mode by adopting SMPS (Switching Mode Power Supply)
- Eliminates waste of electricity in standby mode.- Electricity is wasted when an appliance is connected
to an outlet, even though the appliance is turned off.- Development of a super power-saving SMPS
(Swiching Mode Power Supply)- Minimal standby power consumption (90% reduction
of standby power)- No need to pull the main power plug when the
appliance is not in use.
Two Thermistor ControlThere may be a significant difference between the temperature taken at the installed product and indoor temperature. Two thermistor control provides option to control temperature by referring any of the two temperature. With the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote.
Ceiling Concealed Duct
LCD wired remote controller
Two Thermistor Control
Long Distance & High Elevation PipeThis ceiling concealed duct can be installed at longdistance andhigh height differences from the outdoor as per below table.
Length Elevation
Capacity18k~60k
Max Length50m
Max Elevation30m
Hidden in the ceiling, this product is suitable for applications that require floor level or individual level air conditioning for buildings where there are many rooms or halls, such as restaurants, concert halls and hotels. Installation is not hindered by the location of lighting fixtures or room structure, and interior renovation is made easy with the installation of various ventilation diffusers.
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
External Static Pressure mmAq
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions (WxHxD) mm
Net Weight kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions (WxHxD) mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
1/220~240/50
3.5
12,000
-
-
1.20
-
10.00
-
0.35
-
11.9/9.5/7.9
420/334/277
2
45/42/37
1.37
830x240x450
15.67
5.45
-
Rotary
R22
1,100
50
740x624x270
33.5
6.35
12.70
22.0/19.5
30
10
HB-C126WSA01/220~240/50
5.3
18,000
-
-
1.86
-
9.68
-
0.72
-
20.8/16.3/13.5
734/575/476
2
49/44/39
1.92
950x240x450
17.51
8.00
-
Rotary
R22
1,500
52
870x655x320
62.0
6.35
12.70
22.0/19.5
30
10
HB-C186WSA01/220~240/50
7.0
24,000
-
-
2.48
-
9.68
-
0.72
-
22.9/17.4/14.3
808/614/503
2
50/46/40
2.86
1,210x240x450
21.00
11.00
-
Rotary
R22
2,200
52
870x655x320
62.0
6.35
15.88
22.0/19.5
30
10
HB-C246WSA0 Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
External Static Pressure mmAq
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions (WxHxD) mm
Net Weight kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions (WxHxD) mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm
Max. piping length Main piping m Max. elevation Difference Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
1/220-240/50
8.8
30,000
-
-
3.25
-
9.23
-
1.65
-
30/24/10
1,060/850/353
10
57/51/41
2.6
1,240x300x56
38
15
-
Rotary
R22
1,860
53
870x800x320
73.3
6.35
15.88
22.0/19.0
30
10
HB-C306WSA03/380-415/50
10.3
35,000
-
-
3.75
-
9.33
-
2.45
-
35/32/25
1,240/1,130/880
10
59/55/43
3.5
1,240x328x571
40
6
-
Scroll
R22
2,300
53
870x800x320
73.3
6.35
15.88
22.0/19.0
30
15
HB-C368WSA03/380-415/50
16.7
57,000
-
-
6.50
-
8.77
-
4.22
-
57/47/34
2,010/1,660/1,200
8
62/59/49
5.2
1,646x328x571
54
11.5
-
Scroll
R22
3,350
60
900x1,160x370
103
9.52
19.05
22.0/19.0
30
15
HB-C608WSA03/380-415/50
14.1
48,000
-
-
5.20
-
9.23
-
2.57
-
46/39/26
1,620/1,380/920
10
60/58/47
4.5
1,646x328x571
54
9.0
-
Scroll
R22
2,800
58
900x1,160x370
101
9.52
19.05
22.0/19.0
30
15
HB-C488WSA0
33 33 /34
Ducted
Sp
lit
Vertical Airflow Direction ControlThe airflow direction can be adjusted as desired by using the remote controller.
CEILING & FLOOR CEILING SUSPENDED
Vertical
Horizontal
LG Air Conditioners 2011
Ceiling C
assetteC
eiling Concealed
Duct
Ceiling &
Floor /C
eiling Susp
ended
Single P
ackagedFloor S
tanding
Auto Restart FunctionIn case of a sudden power failure, this feature willautomatically restore the A/C to its previous settings when power returns.
Power Failure
Setting stored beforepower failure.
Power Resume
Auto Restart System
Operation Stop
E2 Prom
Restart
Anti Rust Gold Fin™ (Optional)
Dual Thermistor Control (Optional)
Airflow Direction Control
Time Delay Safety function
LG’s Outdoor Heat Exchanger is coated with a gold-colored anti-corrosive epoxy treatment on the a l u m i n u m c o i l , t o p r e v e n t c o r r o s i o n . T h i s maintainsexcellent heat transfer properties of the coil for an extended time, whereas non-Gold Fin™ coils progressively lose efficiency due to surface corrosion. Gold FinTM fin is perfect for areas with high pollutionor locations exposed to saltwater spray from the sea.
There may be a significant difference between thetemperature taken at the installed product and indoortemperature. Dual thermistor control provides option tocontrol temperature by referring any of the two temperatures. With the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote.
Horizontal Airflow Direction Control. Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand.
It delays restarting of the compressor by three minutespreventing any damage to the compressor
Salt Spray Test for 15 Days
LG Gold Fin™ protected Aluminum
LG Gold Fin™Corrosion Resistance
Uncoated Aluminum
ConventionalStarting to
corrode
• Gold Fin is long lasting, durable and makes the Outdoor Unit look prestigious.
VSLG Gold Fin™ Uncoated Aluminum
Depending on space availability, this model can be installed either on the ceiling or standing On the ceiling or standing on the floor. The vertical flow direction of the cool air can beControlled by remote control and the stylish low-noise design ensures a quiet and comfortableCool environment.
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Specifications18k, 24k
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions (WxHxD) mm
Net Weight kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions (WxHxD) mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm Max. Piping Length Main piping m
Max. elevation Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
1/220-240/50
5270
18000
-
-
1850
-
9.70
8.70
-
14/12/10
500/420/350
43/40/37
5
1200×615×205
30
8.70
-
Rotary(Tropical)
R22
55
870×655×320
55
6.35
15.88
TV-C186BLA01/220-240/50
5270
18000
5270
18000
1850
1750
9.70
10.29
8.70
8.40
14/12/10
500/420/350
43/40/37
5
1200×615×205
30
8.70
8.40
Rotary(Tropical)
R22
55
870×655×320
55
6.35
15.88
TV-H186BLA01/220-240/50
7033
24000
-
-
2400
-
10.00
11.00
-
18/16/12
1120/1020/820
50/48/46
5
1200×615×205
30
11.00
-
Rotary(Tropical)
R22
57
870×655×320
64
6.35
15.88
TV-C246BLA01/220-240/50
7033
24000
7033
24000
2400
2400
10.00
10.00
11.00
11.00
18/16/12
1120/1020/820
50/48/46
5
1200×615×205
30
11.00
11.00
Rotary(Tropical)
R22
57
870×655×320
64
6.35
15.88
TV-H246BLA0
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
39 39 /40
Ducted
Sp
litC
eiling Cassette
Ceiling C
oncealed D
uct C
eiling & Floor /
Ceiling S
uspend
edS
ingle Packaged
Floor Stand
ing
PLASMA Air Purifying System (Washable)
Anti-Bacteria Filter
The integrated PLASMA Air Purifying System removes microscopic contaminants and dust, eliminates offensive odors and prevents allergic reactions. It can also be used as an air-purifying unit only, without running the air conditioner.
It removes dust in the air as well as bacteria proliferation, making the indoor atmosphere healthy
FLOOR STANDING
Dust ReductionRespirable particles from 5 cigarettes in a sealed room removed by LG Plasma Air Purifying System.
DeodorizationLG's Plasma unit effectively removes high concentration tobacco odors confirmed in Sensory tests of odor index carried out in Korea and Japan.
Anti-Allergy In clinical tests, the plasma unit has earned asatisfaction ratio of 82%. Evaluated by CSIRO Australia (DBCE Doc 98/204) Tested by Korean Food Research Institute and Japanese Environmental Centre and Yonsei Univ. College of Medicine. (Allergy Research Lab.)
This is a floor standing type that blends in perfectly with the surroundingdecoration. Clean and fresh air conditioning is ensured with a high level of coolingor heating performance and air purifying operation.
FLOOR STANDING
41 41 /42
Ducted
Sp
litC
eiling Cassette
Ceiling C
oncealed D
uct C
eiling & Floor /
Ceiling S
uspend
edS
ingle Packaged
Floor Stand
ing
Auto Operation(Neuro Fuzzy Control)According to the temperature, air volume and air velocity, the controller will automatically adjust the unit to create the most pleasant atmosphere.
Auto Swing Function
Self Diagnosis Function
LG Floor Standing type is provided auto swing louver that horizontallyspreads a comfortable air blow.
The operating parameters of indoor and outdoor units, and sensor dataat critical locations throughout the s y s t e m , a r e c o n s t a n t l y m o n i t o r e d u s i n g a microcomputer. To facilitate quick response in the event of amalfunction, a message appears on the LED on the unit illuminates.
To sence indoor temperature,humidity and room size
To create optimal cooling condition
To control cooling temperature
To reaiize comfortable, heaithful, low noisey and enegy saving cooling
Like human brain
Like human judgement
Like feeling in the deep forest
Neuro Fuzzy Control
Energy Saving Gold Fin™ (Optional)LG’s Outdoor Heat Exchanger is coated with a gold-colored anti-corrosive epoxy treatment on the a l u m i n u m c o i l , t o p r e v e n t c o r r o s i o n . T h i s maintainsexcellent heat transfer properties of the coil for an extended time, whereas non-Gold Fin™ coils progressively lose efficiency due to surface corrosion. Gold FinTM fin is perfect for areas with high pollutionor locations exposed to saltwater spray from the sea.
Salt Spray Test for 15 Days
LG Gold Fin™ protected Aluminum
LG Gold Fin™Corrosion Resistance
Uncoated Aluminum
ConventionalStarting to
corrode
• Gold Fin is long lasting, durable and makes the Outdoor Unit look prestigious.
VSLG Gold Fin™ Uncoated Aluminum
Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions (WxHxD) mm
Net Weight kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions (WxHxD) mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm Max. Piping Length Main piping m
Max. elevation Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
1/220-240/50
8.15
27,800
-
-
3.00
-
9.27
-
13.5
-
20/18/12/7
706/635/424/247
48/44
3.13
570x1,820x310
32
13.5
-
Rotary
R22
2,150
60
870x800x320
68
9.52
15.88
22/16
30
20
LP-C306R201/220-240/50
8.15
27,800
8.15
27,800
3.05
2.97
9.11
9.36
13.5
13.0
20/18/12/7
706/635/424/247
48/44
3.14
570x1,820x310
32
13.5
13.0
Rotary
R22
2,310
60
870x800x320
68
9.52
15.88
22/16
30
20
LP-H306R201/220-240/50
8.13
27,800
-
-
3.00
-
9.27
-
13.5
-
21.5/19/13
48/46/44
3.17
500x1,800x320
40
13.5
-
Rotary
R22
1,950
60
870x800x320
68
9.52
15.88
22/16
30
20
LP-C306KA(C)01/220-240/50
8.13
27,800
8.13
27,800
3.00
2.87
9.27
9.69
13.5
13.0
21.5/19/13
48/46/44
3.17
500x1,800x320
40
13.5
13.0
Rotary
R22
2,150
60
870x800x320
68
9.52
15.88
22/16
30
20
LP-H306KA(C)0
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Auto Restart FunctionIn case of a sudden power failure, this feature willautomatically restore the A/C to its previous settings when power returns.
Power Failure
Setting stored beforepower failure.
Power Resume
Auto Restart System
Operation Stop
E2 Prom
Restart
Fast CoolingJet Cool Function is quick cooling. In this mode, strong and cool air is blown at highest speed to cool down the room temperature targeting to reach 18ºC.
Hot Start Function(Heat Pump Model Only)During starting of the unit in the heating mode it prevents cold air blown from the unit. It starts the indoor fan only after indoor unit pipe temperature reaches a preset value(28°C). When indoor unit pipe temperature has reached 28°C, then for initial 1 minute the indoor fan runs at low speed and after that at the set fan speed.
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
3/380-415/50
21.10
72,000
-
-
8,000
-
9.00
-
14.0
-
54/-/48
56/-/53
9.5
1,050x1,880x495
110
14.0
-
Scroll
R22
5,000
62
806x1,440x690
140
12.7
25.4
-/25
50
30
TP-C808FLA13/380-415/50
21.11
72,000
23.46
80,000
7,700
7,700
9.35
10.39
13
13
54/-/48
58/-/56
10
1,050x1,880x495
110
13
13
Scroll
R22
8,000
62
1,245x 930x650
150
12.7
25.4
-/25
50
30
TP-H808FLA13/380-415/50
26.50
92,000
-
-
10,000
-
9.20
-
18
-
60/-/55
58/-/56
10
1,050x1,880x495
120
18
-
Scroll
R22
7,500
62
1,280x1,440x690
250
12.7
28
-/25
50
30
TP-C1008FLA0 Power Supply Ø / V / Hz
Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Power Input Cooling kW
Heating kW
EER Cooling Btu/h/W
Heating Btu/h/W
Running Current Cooling A
Heating A
Air flow rate (H/M/L) CMM
CFM
Sound level (H/M/L) dB(A)±3
Dehumidification rate l/h
Dimensions (WxHxD) mm
Net Weight kg
Running Current Cooling A
Heating A
Compressor Type
Refrigerant Type
Charge At 7.5m g
Sound level (H) Sound Pressure dB(A)±3
Dimensions (WxHxD) mm
Net Weight kg
Piping connections Liquid mm
Gas mm
Drain OD/ID mm Max. Piping Length Main piping m
Max. elevation Indoor~outdoor m
Ind
oo
r U
nit
Out
do
or
Uni
t
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
1/220-240/50
7.91
27,000
-
-
2.85
-
9.47
-
13.5
-
17/15/11
47/45/43
3
530x1,760x291
30
13.5
-
Twin Rotary
R22
2,070
57
870x800x320
68
9.52
15.88
-/16
30
15
TP-C306SLA03/380-415/50
14.07
48,000
-
-
5.00
-
9.60
-
8.0
-
31/28/25
54/52/50
6
590x1,850x440
60
8.0
-
Scroll
R22
4,200
60
900x1,130x370
90
9.52
19.05
-/12.5
30
15
TP-C488TLA13/380-415/50
14.07
48,000
14.95
51,000
5.00
5.00
9.60
10.20
8.0
8.5
31/28/25
54/52/50
6
590x1,850x440
60
8.0
8.5
Scroll
R22
4,400
60
900x1,130x370
95
9.52
19.05
-/12.5
30
15
TP-H488TLA1
49 49 /50
Ducted
Sp
litC
eiling Cassette
Ceiling C
oncealed D
uct C
eiling & Floor /
Ceiling S
uspend
edS
ingle Packaged
Floor Stand
ing
FLOOR STANDING
LG Air Conditioners 2011
Easy Installation
Easy Maintenance & Service
Free & Easy Air-Circulation
Additional functions available with duct system
LG’s Cooling Load Calculation ProgramThe unit can be installed outdoors to save valuable
indoor space, or in locations where no ceiling space is available. Ground or roof installation options provide total flexibility according to your requirements.
The all-in-one design, with all access panels located on one side of the unit and color-coded wiring, greatly facilitates aintenance and service.
A duct system allows you to freely control air-circulation.
All units are designed for reverse-cycle operation, which means electric heating functions can be added by special ized dealers. This model also al lows complete control over fresh air intake, ratio of air purification, as well as monitoring and automatic zonecontrol (additional features available from specialized dealers), through the powerful LG control system.
Selecting an air conditioner with the right capacity is very important. A unit that is too small or too big will n o t o n l y a f f e c t y o u r c o m f o r t , b u t m a y a l s o unnecessarily increase your initial purchasing cost and operational expenses. The LG cooling load calculation program helps you choose the right system for your specific needs.
Typical Installation
Roof Jack Installation
Roof Curb Installation
Slab on Ground Installation
1
1
2
3
2
3
Economical and user-friendly model, designed for medium-sized houses and shops.Features include a number of operation modes, auto restart and Easy installation.
SINGLE PACKAGED
51 51 /52
Ducted
Sp
litC
eiling Cassette
Ceiling C
oncealed D
uct C
eiling & Floor /
Ceiling S
uspend
edS
ingle Packaged
Floor Stand
ing
• Tk-C0608ha0• Tk-C0368ha0• Tk-C0488ha0
SINGLE PACKGEDSINGLE PACKGED
LG Air Conditioners 2011
Specifications Specifications
Cooling Gross Capacity Btu/h
Capacity W
Net Capacity Btu/h
W
Electrical Power Supply ø/ V / Hz
Data M.C.A Cooling Amps
(with standard motor) Heating Amps
Power Input Cooling W
Heating W
Performance Air circulation Normal CFM
EER Cooling Btu/h W
Sound Rating Outdoor,Max dB(A)±3
Evaporator Type
Tube size(O.D) inch
mm
Row/ Column/ FPI
Face Area sq.ft
m2
Indoor Fan Type
No. Used
Drive Type/ Motor Step
No of Motors
Motor rpm(H/M/L or Medium or
Standard/ Oversiezed)
Compressor Type
Quantity
Maker
Capacity Btu/h
Condensor Type
Tube size(O.D) inch
mm
Row/ Column/ FPI
Face Area sq.ft
m2
Drain Connection Size inch
Dimensions Indoor unit(W*H*D) mm
Net Weight kg(lbs)
Cooling Gross Capacity Btu/h
Capacity W
Net Capacity Btu/h
W
Electrical Power Supply ø/ V / Hz
Data M.C.A Cooling Amps
(with standard motor) Heating Amps
Power Input Cooling W
Heating W
Performance Air circulation Normal CFM
EER Cooling Btu/h W
Sound Rating Outdoor,Max dB(A)±3
Evaporator Type
Tube size(O.D) inch
mm
Row/ Column/ FPI
Face Area sq.ft
m2
Indoor Fan Type
No. Used
Drive Type/ Motor Step
No of Motors
Motor rpm(H/M/L or Medium or
Standard/ Oversiezed)
Compressor Type
Quantity
Maker
Capacity Btu/h
Condensor Type
Tube size(O.D) inch
mm
Row/ Column/ FPI
Face Area sq.ft
m2
Drain Connection Size inch
Dimensions Indoor unit(W*H*D) mm
Net Weight kg(lbs)
Nomianl Ton Nomianl Ton
35,700
10,462
34,500
10,111
3/380-415/50
13
4,000
1,200
8.93
77
High Efficiency
3/8
9.52
2R/28c/18FPI
4.51
0.42
Centrifugal blower
1 ea
Direct /3
1 ea
860/755/655
Scroll
1
LG
34,500
High Efficiency
9/32
7
1R/36c/18FPI
10.72
1
3/4
1,111*824*734
110(243)
TK-C0368HA0
3 RT
59,900
17,554
58,000
16,998
3/380-415/50
20.4
6,400
2,000
9.36
80
High Efficiency
3/8
9.52
3R/28c/18FPI
4.51
0.42
Centrifugal blower
1 ea
Direct /2
1 ea
1020/920
Scroll
1
LG
59,000
High Efficiency
9/32
7
1R/36c/19FPI
10.72
1
3/4
1,111*824*734
140(309)
TK-C0608HA0
5 RT
48,400
14,184
47,000
13,774
3/380-415/50
15.2
4,900
1,600
9.80
79
High Efficiency
3/8
9.52
3R/28c/18FPI
4.51
0.42
Centrifugal blower
1 ea
Direct /3
1 ea
1020/860/715
Scroll
1
LG
47,000
High Efficiency
9/32
7
2R/36c/18FPI
3/4
1,111*824*734
120(265)
TK-C0488HA0
4 RT
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification. Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Refrigerant System Single Compressor to Minimize Installation Cost
Unit casing constructed with electrostatic galvanized steel sheet. Exterior surfaces shall be cleaned, phosphatized and finished with a polyester powder painting and weather-resistant baked enamel finish.
The ditrect drive and belt drive fan can be adjusted according to the air volume and static pressure reauirement. The flexibility allow for wider application.
All motors have 10 percent voltage utilization range and wired to unit internal box. Motors are design for long life.
LG ducted split can easily be converted for vertical and horizontal air discharge depending on the characteristics of space and apply application where the unit installed.
Scroll compressor optimum energysaving performance and quieteroperation made possible byreducing overhead losses.
LG engineered fan & heat transfer system provides maximum cooling and airf low while minimizing vibration, acoustic level and power consumption.
LG ducted split designed to have compact casing to suite the need for retrofit, renovation and replacement market. The compact designed ensures economical use of building space.
Selecting an air conditioner with the right capacity is very important. A unit that is too small or too big will n o t o n l y a f f e c t y o u r c o m f o r t , b u t m a y a l s o unnecessarily increase your initial purchasing cost and operational expenses. The LG cooling load calculation program helps you choose the right system for your specific needs.
* 15HP construct in single circuit to save installation and material cost
8HP
8HP
•
•
•
Single Circuit
Direct Drive(220/1-50)
Belt Drive(380/3/50)
Fan Motor
Dual Circuit
10HP
10HP
•
•
•
12HP
12HP
•
•
•
15HP
15HP
•
•
•
20HP
20HP
•
•
•
25HP
25HP
•
•
•
30HP
30HP
•
•
•
Horizontal Discharge
Vertical Discharge
This unit is used for medium sized office and hotels specially mixed with various otherProducts. It has high efficient scroll compressors and stable with anti corrosion.
DUCTED SPLIT
55 55 /56
Ducted
Sp
litC
eiling Cassette
Ceiling C
oncealed D
uct C
eiling & Floor /
Ceiling S
uspend
edS
ingle Packaged
Floor Stand
ing
• Tn-C0908T00• Tn-C1208T00
• Tn-C0368sa0• Tn-C0488sa0• Tn-C0608sa0
DUCTED SPLITDUCTED SPLIT
LG Air Conditioners 2011
Model Structure
Air Filter Guide
Blower Housing Ass'y
"A" Type Indoor Coil
Plastic Drain Pan
10 RT7.5 RT4 RT, 5 RT3 RT
Specifications
Power Supply Ø / V / Hz
Cooling Capacity Gross kW
Btu/h
Net kW
Btu/h
EER Cooling Btu/h/W
M.C.A (with standard motor) Amps
Power Input kW
Air flow rate Nominal CFM
Sound Rating bell
Refrigerant Type
Charge kg
Connection Tube Liquid mm(inch)
Gas mm(inch)
Drain Connection Size Outdoor mm(inch)
Dimensions (WxHxD) Indoor mm
Outdoor mm
Net Weight Indoor kg
Outdoor kg
Compressor Type
3/380-415/50
10.84
37,000
10.40
35,500
9.02
9.7
4.10
1,150
6
R22
2.1
9.52(3/8)
15.88(5/8)
19.05(3/4)
470x1,014x480
870x800x320
59
65
Scroll
TN-C0368SA03/380-415/50
14.51
49,500
13.77
47,000
9.90
13.9
5.00
1,800
6.2
R22
4.5
9.52(3/8)
19.05(3/4)
19.05(3/4)
600x1,135x500
900x1,135x370
63
100
Scroll
TN-C0488SA03/380-415/50
17.58
60,000
16.70
57,000
10.34
16.5
5.80
1,900
6.2
R22
4.2
12.7(1/2)
19.05(3/4)
19.05(3/4)
600x1,135x500
900x1,135x370
65
115
Scroll
TN-C0608SA0
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.
Nomianl Ton 3 RT 4 RT 5 RT
Specifications
Power Supply Ø / V / Hz
Cooling Capacity Gross kW
Btu/h
Net kW
Btu/h
EER Cooling Btu/h/W
M.C.A (with standard motor) Amps
Power Input kW
Air flow rate Nominal CFM
Sound Rating bell
Refrigerant Type
Charge kg
Connection Tube Liquid mm(inch)
Gas mm(inch)
Drain Connection Size Outdoor mm(inch)
Dimensions (WxHxD) Indoor mm
Outdoor mm
Net Weight Indoor kg
Outdoor kg
Compressor Type
Note : Due to our policy of innovation some specifications (* especially noise level) may be changed without notification.