KELLER AG für Druckmesstechnik CH-8404 Winterthur +41 52 235 25 25 [email protected] KELLER Ges. für Druckmesstechnik mbH DE-79798 Jestetten +49 7745 9214 0 [email protected] Edition 10/2020 Subject to alterations Companies approved to ISO 9001 www.keller-druck.com LEO5 8 1 , 8 40 4 1 1 2 27 SW 27 30 G 1/4 LEO5 manometer LEO5 with rubber cover 1 2 29,5 45 8 9 , 5 3 6 , 5 G 1/4 30 SW 27 High-resolution digital manometer Features Insulated piezoresistive pressure sensor encapsulated in an oil-filled metal housing Robust, watertight stainless steel housing with safety glass front Large, backlit LC display Integrated rechargeable battery (USB chargeable) • License-free KELLER software available to download Also available as LEO5-BT with integrated Bluetooth interface Functions High-resolution pressure measurements Pressure peak detection with 5 kHz sampling frequency Data logger Operated via capacitive touch keys Bar graph display Temperature display Min/max display Typical Applications Pressure testing • Calibration Laboratory use • Industrial applications Accuracy ± 0,05 %FS Total Error Band ± 0,1 %FS Pressure Ranges -1...3 bar to 0...1000 bar
5

LEO5 - KELLER-Druck

Dec 18, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LEO5 - KELLER-Druck

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 10/2020Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

LEO5

81,8

40

4112

27

SW 27

30

G 1/4

12

29,5

45

89

,5

36,5

G 1/4

30

SW 27

LEO5 manometer LEO5 with rubber cover

81,8

40

4112

27

SW 27

30

G 1/4

12

29,5

45

89

,5

36,5

G 1/4

30

SW 27

High-resolution digital manometer

Features

• Insulated piezoresistive pressure sensor encapsulated in an oil-filled metal housing• Robust, watertight stainless steel housing with safety glass front• Large, backlit LC display• Integrated rechargeable battery (USB chargeable)• License-free KELLER software available to download• Also available as LEO5-BT with integrated Bluetooth interface

Functions

• High-resolution pressure measurements• Pressure peak detection with 5 kHz sampling frequency• Data logger• Operated via capacitive touch keys• Bar graph display• Temperature display• Min/max display

Typical Applications

• Pressure testing• Calibration• Laboratory use• Industrial applications

Accuracy± 0,05 %FSTotal Error Band± 0,1 %FSPressure Ranges-1...3 bar to 0...1000 bar

Page 2: LEO5 - KELLER-Druck

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 10/2020Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Page 2 of 5

LEO5 – SpecificationsStandard Pressure Ranges

Gauge pressure, PR -1…1 -1…3 -1…6 -1…10 -1…16 -1…30 bar rel.

Absolute pressure, PAA 0…2 0…4 0…7 0…11 0…17 0…31 0…61 0…101 0…161 bar abs.

Absolute pressure, PA 0…300 0…400 0…700 0…1000 bar

Overload resistance 8 8 20 20 40 60 200 200 300 600 800 1100 1100 bar

Display resolution 0,0001 0,0001 0,001 0,001 0,001 0,001 0,001 0,01 0,01 0,01 0,02 0,05 0,1 bar

KeyPR Gauge pressure Zero at atmospheric pressurePAA Absolute pressure Zero at 0 bar abs. (vacuum)PA Absolute pressure Zero at 1 bar abs.

Performance

Accuracy @ RT (20...25 °C) ≤ ± 0,05 %FS Nonlinearity (BFSL), pressure hysteresis, non-repeatability, zero point, amplification

Total error band (0...50 °C) ≤ ± 0,1 %FS Max. deviation within the specified pressure and temperature range

Long-term stability ≤ ± 0,1 %FS Per year under reference conditions, yearly recalibration recommended

Degree of dependency on location ≤ ± 1,5 mbar Calibrated in vertical installation position with pressure connection facing downwards

Accuracy of temperature measurement ± 1 °C typ.

Pressure range reserve ± 10%

Vacuum endurance ≤ 0,2 bar abs. Of operation ≤ 0,2 bar abs. upon request

Temperature Ranges

Compensated temperature range 0…50 °C

Media temperature -10…60 °C

Ambient temperature 0…50 °C

Storage temperature -20…70 °C

Electrical Data

Rechargeable battery Lithium-ion 4,2 V / 2,3 Ah

Battery life (standard) Up to 2000 hours of continuous operation

Battery life (peak mode) Up to 160 hours of continuous operation

Battery charging cycles > 300

GND case insulation > 10 MΩ @ 300 VDC

External interface USB (KELLER protocol), Bluetooth classic (LEO5-BT)

Interface measuring rate 2 measurements per second

Electrical connection Mini USB-B

CE conformity as per 2014/30/EU (EMC) EN 61000-6-1 to -6-4, EN 61326-1 / EN 61326-2-3

Page 3: LEO5 - KELLER-Druck

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 10/2020Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Page 3 of 5

LEO5 – SpecificationsElectrical Data

Data logger

Logger function Records pressure, temperature and measuring time

Data storage ≥ 56 000 measured values

Recording modes Interval, event-controlled

Measuring rate ≥ 1 second, can be configured in 1-second increments

Display

Dimensions/appearance Width × height: 51,3 mm × 38,8 mm, also refer to Dimensions and options

Number of digits on LC display 2 rows with 5 digits each

Display mode Pressure + min/max or pressure + temperature, additional bar graph

Measuring rate (standard) 2 measurements per second

Measuring rate (peak mode) 5 kHz (reduced resolution and accuracy)

Configurable units of pressure [bar], [mbar], [Pa], [hPa], [kPa], [MPa], [PSI], [mH2O], [cmH2O], [inH2O], [ftH2O], [mmHg], [inHg], [kp/cm2]

Additional units of pressure 5 user-defined units can be configured

Mechanical Data

Materials in contact with media

Pressure connection Stainless steel AISI 316L

Pressure transducer separating diaphragm Stainless steel AISI 316L

Pressure transducer seal (internal) FKM (Viton® type A)

Pressure connection seal (external) FKM (Viton® type A)

Other materials

Display housing Stainless steel AISI 304

Oil filling pressure transducer Silicone oil

Further details

Pressure connection G1/4 Other options see available pressure connections

Diameter × height × depthApprox. 82 mm × 135 mm × 40 mm Without rubber cover

Approx. 90 mm × 139 mm × 45 mm With rubber cover

Weight Approx. 430 g

Protection IP66

Page 4: LEO5 - KELLER-Druck

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 10/2020Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Page 4 of 5

LEO5 – Dimensions and OptionsLC Display External Connection

Front cover Content Dimensions

P1:1

R1:1

T2 : 1

U2 : 1

P

R

T

U

Width × height:51,3 mm × 38,8 mm

Digit height:top: 15 mm × 7 mmbottom: 10,5 mm × 4,5 mm

Available Pressure Connections

G1/4 (standard) G1/2 1/4 NPT 1/2 NPT G1/2 EN 837

7/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/4

7/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/4

7/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/4

G1/2 flush G3/4 flush 7/16-20 UNF Clamp DIN 32676 flush G1/4 EN 837

7/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5G1

/4"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT

20

133

5

G1/47/16-20 UNF-2A

15

37°50,5

43,5

G1/4

"

G1/4

"

14

G1/2G3/4

16

G1/2

205

6

12

G1/4G1/2

14

1/4-18 NPT

15

1/2-14 NPT20

133

5

G1/4

Other pressure connections available upon request.

Optional Advanced Versions

Standard Detached sensors Bluetooth interface

Other Customer-specific Options

• Evaluation on other pressure areas• Evaluation on other temperature ranges• Parts that come into contact with media made from Hastelloy, Inconel or titanium• Customer-specific front covers• Customer-specific firmware with e.g. application-specific calculations• Other sealing materials for pressure transducers• Other oil fillings for pressure transducers

Placement Mini USB-B connection

P1:1

R1:1

T2 : 1

U2 : 1

P

R

T

U

P1:1

R1:1

T2 : 1

U2 : 1

P

R

T

U

Page 5: LEO5 - KELLER-Druck

KELLER AG für DruckmesstechnikCH-8404 Winterthur

+41 52 235 25 25 [email protected]

KELLER Ges. für Druckmesstechnik mbHDE-79798 Jestetten

+49 7745 9214 0 [email protected]

Edition 10/2020Subject to alterationsCompanies approved to ISO 9001

www.keller-druck.com

Page 5 of 5

LEO5 – Software, Scope of Delivery and Accessories«Logger 5» Software

The Logger 5 software is suitable for the following activities:• Reading data from the autonomous data collec-

tor, e.g. LEO5, and saving to a file on a PC• Programming and configuring the data logger• Active reading of the pressure and temperature

measured values in one-second intervals and presenting the data in graphs

• Visualising and analysing measurements saved in files

• Printing out reports or saving them as PDF files• Exporting data and making it available to other

applications for further processing• Performing level measurement calculations

«CCS30» Software

Recording measured values• Live visualisation• Adjustable measuring and storage interval• Export function

Configuration• Call up of information (pressure and temperature

range, firmware version, serial number etc.)

“ManoConfig” Software

The ManoConfig program is compatible with various types of KELLER manometers and allows end cus-tomers to configure the devices.

Range of functions• Display of online measured values• Configuring the wait period before automatic

shutdown• Selecting standard pressure units• Activating/deactivating pressure units• Programming user-defined pressure units• Restoring to factory settings• Calibrating the manometer

Interface

The LEO5 manometer has a USB interface. Details of the communication protocols can be found at www.keller-druck.com. Documentation, a Dynamic Link Library (DLL) and various programming exam-ples are available to integrate the communication protocol into your own software.

Scope of Delivery

Plastic case USB cable KELLER 5-point report Operating instructions D/E/F

Prüfprotokoll

KELLER AG für Druckmesstechnik, St.Gallerstrasse 119, CH-8404 Winterthur, Tel. +41 52 235 25 25KELLER Ges. für Druckmesstechnik mbH, Schwarzwaldstrasse 17, D-79798 Jestetten, Tel. +49 77 45 92 14 0

0.1003.0006.0009.000

11.000

bar abs

0.1013.0006.0009.000

11.000

bar abs

0.0090.0000.0000.0000.000

%FS

Mensor 600 (5,5 / 11 bar abs)PM 02324

940 26mbar °C

0 11 bar abs0 11 bar abs

LEX1 / 11bar / 81750.5

0...50°C

Tech.Bezeichnung

Best.Nr

3V Batt.Ausgang/Speisung

Serienummer

... ...

DruckquelleMessgerätLuftdruck Temperatur

DruckbereichAnzeige

Komp. Temperaturbereich

Druck Anzeige Fehler

Kunde

Prod.Nr 303030.0013

Auftrag Nr Pos 1

Genauigkeit RT [%FS] 0.050

Datum02.10.2020

Prüfer / Prüferin

Rückverfolgbarkeit der Prüfmittel auf Nationale Normale bei KELLERgemäss https://download.keller-druck.com/api/download/ZrTYZLc3qYiyFfzrLbdYx7/de/latest.pdf

Zertifiziert nach ISO 9001:2015 www.keller-druck.com

Hochauflösendes Manometer mit Peak- und Aufzeichnungs-Funktion High Resolution Manometer with Peak and Record Function

Manomètre haute résolution avec fonctions d’enregistrement et de mesure des pics de pression

Betriebsanleitung · Operating Instructions · Notice d’utilisation

Swiss Made

LEO 5

Hinweis: Entlüftungsmembrane nicht eindrücken. Note: Do not touch/press ventilation film.Remarque: Ne pas appuyer sur la membrane de ventilation.

Accessories

Rubber cover KELLER 11-point report Calibration certificate

11 Punkte Prüfprotokoll

KELLER AG für Druckmesstechnik, St.Gallerstrasse 119, CH-8404 Winterthur, Tel. +41 52 235 25 25KELLER Ges. für Druckmesstechnik mbH, Schwarzwaldstrasse 17, D-79798 Jestetten, Tel. +49 77 45 92 14 0

Auftrag Nr

Druck DPI 515 (-1...3,5 / -1...35 bar)PM 02230

960 24mbar °C

0 4 bar abs0 4 bar abs

LEO2 / -1...3bar / 81021

0...50°C

Tech.Bezeichnung

Best.Nr

3V Batt.Ausgang/Speisung

0.1000.8001.6002.4003.200

bar abs0.1000.8001.6002.4003.2004.000

bar abs

Serienummer

...

...

0.1000.8001.6002.4003.2004.000

bar abs0.0000.0000.0000.0000.0000.000

%FS0.1000.8001.6002.4003.200

bar abs0.0000.0000.0000.0000.000

%FS

0.000

0.0000.000

Druckquelle

MessgerätLuftdruck Temperatur

DruckbereichAnzeige

Komp. Temperaturbereich

Druck Druck Anzeige Anzeige Fehler Hysterese

Max. Fehler %FS

Beste Gerade

Endpunktlin.

Fehlerband

Kunde

Prod.Nr 303010.0002

0.0000.0000.0000.0000.000

%FS

Fehler

Pos 1

Genauigkeit RT [%FS] 0.100

Datum

28.10.2019Prüfer / Prüferin

Rückverfolgbarkeit der Prüfmittel auf Nationale Normale bei KELLERgemäss http://www.keller-druck.ch/picts/pdf/german/70AA005_g.pdf

Zertifiziert nach ISO 9001:2015 www.keller-druck.com

For additional protection in harsh environments

Measurement deviation at room temperature with hysteresis

Issued by the external calibration laboratory of the German accreditation body DAkkS or the Swiss accredita-tion body SAS