EXISTING STAGE 12 EXISTING STAGE 15 EXISTING STAGE 2 EXISTING STAGE 1A EXISTING STAGE 10 EXISTING STAGE 5 EXISTING STAGE 3 EXISTING STAGE 4 EXISTING STAGE 9 EXISTING STAGE 1A1 HAYES HILL BLVD PATERSON DRIVE OLIVINE BOULEVARD COACH DRIVE ORIEL ROAD EASTROW AVENUE OLIVINE BOULEVARD COLISEUM AVENUE ACADEMY LANE CYCAD AVENUE OLIVINE BOULEVARD HAYES HILL BLVD DOWNTOWN AVENUE MEDIAN GRANGE VICINITY ROAD METROPOLIS WAY SOCIETY VISTA PRECINCT WAY COMPASS CRESCENT WILLOWMEAD BLVD DAYBROOK SILVER DONNYBROOK ROAD STREET TERRACE VERDANT DRIVE HARDWOOD GROVE CIRCUIT FINN AVENUE OAKFIELD ENTRANCE EUCALYPTUS PARADE COMMONWEALTH STAGE 17 WORKS AREA GLADE LEAGUE ROAD EXISTING STAGE 14 EXISTING STAGE 13 EXISTING STAGE 11 PATCH of Olivine Estate - Stage 17 Whittlesea City Council Functional Design Cover Plan & Typical Cross Sections 8M2 1700E-017-001 01 03 A Collins Square, Tower 4, Level 20, 727 Collins St Melbourne, VIC, 3008, Australia 03 9514 1500 A 28.01.21 ISSUED TO COUNCIL FOR APPROVAL N.MEELAUD Y.SONG T.MOTET A.BURROWS PLAN OF SUB. NO. PERMIT REF. NO. N CHECKER APPROVER AMENDMENT / REVISION DESCRIPTION DATE REV DESIGNER PROJECT / DRAWING No. REVISION SCALE AS SHOWN AT A1 DRAFTER ABN 47 065 475 149 C DISCLAIMER: All setting out should be carried out in accordance with MPA/Council's standard drawings or as nominated on hard copy plans provided by SMEC. Any digital information supplied by this office is for information only. Any discrepancies should be discussed with the superintendent. MELWAYS REF DWG PATH: V:\_Vault\Projects_Urban\1700E-Olivine\1700E-17\Dwgs\1700E-017-001.dwg PRINTED BY: NM15662 on 03/02/2021 at 05:04:31 PM SHEET No. WARNING BEWARE OF UNDERGROUND SERVICES The l oca t i ons o f underground serv i ces are approx i ma t e on l y and t he i r exac t pos i t i on shou l d be proven on s i t e . No guaran t ee i s g i ven t ha t a l ex i s t i ng serv i ces are shown . Loca t e a l underground serv i ces be f ore commencemen t o f works DIAL 1100 BEFORE YOU DIG www.1100.com.au Drawing Index 1700E-017-001 Cover Plan & Typical Cross Sections 1700E-017-002 Layout Plan 1700E-017-031 Parking Plan Olivine Estate Stage 17 LOCALITY PLAN MELWAYS REF: 8M2 SERVICES OFFSET SCHEDULE ROAD NAME GAS NON-DRINKING WATER DRINKING WATER ELECTRICITY NBN SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m) LEAGUE ROAD NORTH 2.10 NORTH 2.60 NORTH 3.10 SOUTH 2.55 SOUTH 1.85 PATCH ROAD SOUTH 2.10 SOUTH 2.60 SOUTH 3.10 NORTH 2.55 NORTH 1.85 ROAD LAYOUT TABLE ROAD NAME RESERVE WIDTH (m) ROAD WIDTH (m) KERB TYPE VERGE WIDTH (m) LIP to LIP INV to INV BACK to BACK NTH/WEST STH/EAST NTH/WEST STH/EAST LEAGUE ROAD 16.00 6.40 7.30 7.60 B2 B2 4.35 4.35 PATCH ROAD 16.00 6.40 7.30 7.60 B2 B2 4.35 4.35 16m ACCESS STREET LEAGUE ROAD, PATCH ROAD 2.80m 3.65m 3.65m 2.80m 16.00m FTTH 1850 OFF BDY 1.50m 1.50m LOTS LOTS ELECTRICITY 2350 OFF BDY GAS MAIN 2100 OFF BDY WATER MAIN 3100 OFF BDY 1 in 30 1 in 30 1 in 50 1 in 50 B2 B2 RECYC WATER 2600 OFF BDY 8m 0.05m 0.05m 8m LEGEND - FUNCTIONAL LAYOUT PLAN ALL PROPOSED, FUTURE & EXISTING SERVICE LOCATIONS ARE SHOWN INDICATIVELY STORMWATER DRAIN, PIT & PROPERTY INLET SWALE DRAIN SEWER & MAINTENANCE STRUCTURES HOUSE DRAIN ELECTRICITY (U.GROUND) GAS TELSTRA WATER RECYCLE WATER AG. DRAIN SERVICE CONDUITS TACTILE PAVERS EXISTING STORMWATER DRAIN EXISTING SWALE DRAIN EXISTING SEWER & MAINTENANCE STRUCTURES EXISTING HOUSE DRAIN EXISTING ELECTRICITY (UNDER GROUND) EXISTING GAS EXISTING TELSTRA EXISTING WATER EXISTING RECYCLED WATER EXISTING AG. DRAIN EXISTING SERVICE CONDUITS EXISTING TACTILE PAVERS FUTURE STORMWATER DRAIN FUTURE SWALE DRAIN FUTURE SEWER & MAINTENANCE STRUCTURES FUTURE HOUSE DRAIN FUTURE ELECTRICITY (UNDER GROUND) FUTURE GAS FUTURE TELSTRA FUTURE WATER FUTURE RECYCLED WATER FUTURE AG. DRAIN FUTURE SERVICE CONDUITS FUTURE TACTILE PAVERS ZERO LOT LINES DIRECTION OF FALL OVERLAND FLOW GRADED IN DIRECTION OF FALL TO LEVEL INDICATED EDGE STRIP, SUBSOIL DRAIN, "NO ROAD" SIGN & BARRIER EXISTING RED GUMTREE & CANOPY TO BE REMOVED EXISTING OTHER SPECIES TREE & CANOPY TO BE REMOVED EXISTING RED GUM TO BE RETAINED EXISTING OTHER SPECIES TO BE RETAINED BOLLARDS H GW H GWR H GWR LV CABLE COMMS CONDUIT TYPICAL SHARED TRENCH DETAIL LEAGUE ROAD, PATCH ROAD 450mm 600mm 150mm
3
Embed
LEGEND - FUNCTIONAL LAYOUT PLAN ALL PROPOSED, FUTURE ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
EXISTINGSTAGE 12
EXISTINGSTAGE 15
EXISTINGSTAGE 2
EXISTINGSTAGE 1A
EXISTINGSTAGE 10
EXISTINGSTAGE 5
EXISTINGSTAGE 3
EXISTINGSTAGE 4
EXISTINGSTAGE 9
EXISTINGSTAGE 1A1
HAYES HILL BLVD
PATE
RSO
N D
RIV
E
OLIVINE BOULEVARD
COACH DRIVE
OR
IEL
RO
AD
EAST
RO
W A
VEN
UE
OLI
VIN
E BO
ULE
VAR
D
COLISEUM AVENUE
ACAD
EMY
LAN
E
CYCAD AVENUE
OLI
VIN
E BO
ULE
VAR
D
HAYES HILL BLVD
DO
WN
TOW
N A
VEN
UE
MED
IAN
GR
ANG
E
VIC
INIT
Y R
OAD
METROPOLIS WAY
SOCIETY
VIS
TA
PREC
INC
T W
AY
COMPASS CRESCENT
WILLOWMEAD BLVD
DAY
BRO
OK
SILV
ER
DONNYBROOK ROAD
STR
EET
TER
RAC
E VERDANT DRIVE
HARDWOOD GROVE
CIR
CU
IT
FINN AVENUE
OAKFIELD
ENTR
ANCE
EUC
ALYP
TUS
P
ARAD
E
COMMONWEALTH
STAGE 17WORKS AREA
GLADE
LEAGUE ROAD EXISTINGSTAGE 14
EXISTINGSTAGE 13
EXISTINGSTAGE 11
PATCH
of
Olivine Estate - Stage 17Whittlesea City Council
Functional DesignCover Plan & Typical Cross Sections
DISCLAIMER: All setting out should be carried out in accordance with MPA/Council's standard drawings or as nominated on hard copy plans provided by SMEC. Any digital information supplied by this office is for information only. Any discrepancies should be discussed with the superintendent.
MELWAYS REF
DWG PATH: V:\_Vault\Projects_Urban\1700E-Olivine\1700E-17\Dwgs\1700E-017-001.dwg PRINTED BY: NM15662 on 03/02/2021 at 05:04:31 PM
SHEET No.
WARNINGBEWARE OF UNDERGROUND SERVICES
The locations of underground services are approximate only andtheir exact position should be proven on site.
No guarantee is given that all existing services are shown.Locate all underground services before commencement of works
DIAL 1100 BEFORE YOU DIGwww.1100.com.au
Drawing Index1700E-017-001 Cover Plan & Typical Cross Sections 1700E-017-002 Layout Plan 1700E-017-031 Parking Plan
Olivine EstateStage 17
LOCALITY PLANMELWAYS REF: 8M2
SERVICES OFFSET SCHEDULE
ROAD NAMEGAS NON-DRINKING WATER DRINKING WATER ELECTRICITY NBN
SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m) SIDE OFFSET (m)
LEAGUE ROAD NORTH 2.10 NORTH 2.60 NORTH 3.10 SOUTH 2.55 SOUTH 1.85PATCH ROAD SOUTH 2.10 SOUTH 2.60 SOUTH 3.10 NORTH 2.55 NORTH 1.85
ROAD LAYOUT TABLE
ROAD NAME RESERVE WIDTH (m)ROAD WIDTH (m) KERB TYPE VERGE WIDTH (m)
LIP to LIP INV to INV BACK to BACK NTH/WEST STH/EAST NTH/WEST STH/EASTLEAGUE ROAD 16.00 6.40 7.30 7.60 B2 B2 4.35 4.35PATCH ROAD 16.00 6.40 7.30 7.60 B2 B2 4.35 4.35
16m ACCESS STREETLEAGUE ROAD, PATCH ROAD
2.80m3.65m3.65m2.80m
16.00m
FTTH
1850
OFF
BDY
1.50m1.50m
LOTS
LOTS
ELEC
TRIC
ITY
2350
OFF
BDY
GAS
MAIN
2100
OFF
BDY
WAT
ER M
AIN
3100
OFF
BDY
1 in 301 in 30
1 in 501 in 50B2 B2
RECY
C W
ATER
2600
OFF
BDY
8m
0.05m 0.05m
8m
LEGEND - FUNCTIONAL LAYOUT PLANALL PROPOSED, FUTURE & EXISTING SERVICE LOCATIONS ARE SHOWN INDICATIVELY
STORMWATER DRAIN, PIT& PROPERTY INLETSWALE DRAINSEWER & MAINTENANCE STRUCTURESHOUSE DRAINELECTRICITY (U.GROUND)GASTELSTRAWATERRECYCLE WATERAG. DRAINSERVICE CONDUITSTACTILE PAVERSEXISTING STORMWATER DRAINEXISTING SWALE DRAINEXISTING SEWER & MAINTENANCESTRUCTURESEXISTING HOUSE DRAINEXISTING ELECTRICITY (UNDER GROUND)EXISTING GASEXISTING TELSTRAEXISTING WATEREXISTING RECYCLED WATEREXISTING AG. DRAINEXISTING SERVICE CONDUITSEXISTING TACTILE PAVERSFUTURE STORMWATER DRAINFUTURE SWALE DRAINFUTURE SEWER & MAINTENANCESTRUCTURESFUTURE HOUSE DRAINFUTURE ELECTRICITY (UNDER GROUND)FUTURE GASFUTURE TELSTRAFUTURE WATERFUTURE RECYCLED WATERFUTURE AG. DRAINFUTURE SERVICE CONDUITSFUTURE TACTILE PAVERSZERO LOT LINESDIRECTION OF FALLOVERLAND FLOWGRADED IN DIRECTION OF FALL TO LEVELINDICATEDEDGE STRIP, SUBSOIL DRAIN,"NO ROAD" SIGN & BARRIEREXISTING RED GUMTREE & CANOPY TO BEREMOVEDEXISTING OTHER SPECIES TREE &CANOPY TO BE REMOVED
DISCLAIMER: All setting out should be carried out in accordance with MPA/Council's standard drawings or as nominated on hard copy plans provided by SMEC. Any digital information supplied by this office is for information only. Any discrepancies should be discussed with the superintendent.
MELWAYS REF
DWG PATH: V:\_Vault\Projects_Urban\1700E-Olivine\1700E-17\Dwgs\1700E-017-002.dwg PRINTED BY: NM15662 on 03/02/2021 at 05:05:06 PM
SHEET No.
WARNINGBEWARE OF UNDERGROUND SERVICES
The locations of underground services are approximate only andtheir exact position should be proven on site.
No guarantee is given that all existing services are shown.Locate all underground services before commencement of works
DISCLAIMER: All setting out should be carried out in accordance with MPA/Council's standard drawings or as nominated on hard copy plans provided by SMEC. Any digital information supplied by this office is for information only. Any discrepancies should be discussed with the superintendent.
MELWAYS REF
DWG PATH: V:\_Vault\Projects_Urban\1700E-Olivine\1700E-17\Dwgs\1700E-017-031.dwg PRINTED BY: NM15662 on 03/02/2021 at 05:05:37 PM