GE Lighting Data sheet GE imagination at work Tetra Contour is comprised of a flexible LED light engine and a rigid, optically diffused light guide that can be heat formed to fit a variety of architectural needs. With a variety of colors to choose from, designers can mix-n-match components to create bold designs and attractive accent lighting without the typical worries of working with fragile neon glass. Tetra Contour is ideal for border lighting, interior art, cove and accent lighting Features & Benefits • Up to 40% more energy efficient than neon • Low-voltage 24VDC system • Dimmable with GE 0-10V Dimming Driver or GE Dim- ming Module and compatible dimming controller • Contains no lead, mercury or glass. RoHS compliant • Long rated life of 50,000 hours • Multiple ANSI bin color temperatures: red, green, blue, white & warm white • Light guide colors: red, green, blue, white & clear • 5 years warranty • IP66 system rating with light guide Tetra ® Contour LED ARCHITECTURAL SERIES
4
Embed
LED Tetra Contour Data sheet EN - RS Components · 2019. 10. 13. · Tetra Contour is comprised of a flexible LED light engine and a rigid, optically diffused light guide that can
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
GE Lighting
Data sheet
GE imagination at work
Tetra Contour is comprised of a flexible LED light engine and a rigid, optically diffused light guide that can be heat formed to fit a variety of architectural needs. With a variety of colors to choose from, designers can mix-n-match components to create bold designs and attractive accent lighting without the typical worries of working with fragile neon glass.
Tetra Contour is ideal for border lighting, interior art, cove and accent lighting
Features & Benefits• Up to 40% more energy efficient than neon• Low-voltage 24VDC system• Dimmable with GE 0-10V Dimming Driver or GE Dim-
ming Module and compatible dimming controller• Contains no lead, mercury or glass. RoHS compliant• Long rated life of 50,000 hours• Multiple ANSI bin color temperatures: red, green,
blue, white & warm white• Light guide colors: red, green, blue, white & clear• 5 years warranty• IP66 system rating with light guide
Tetra® ContourLED ARCHITECTURAL SERIES
Bulk pack
Single pack
Product Pack
Qty
PackQty
Code
75481 12/PK
6/PK
6/PK
6/PK
6/PK
6/PK
6/PK
6/PK
6/PK
1/PK
1/PK
1/PK
1/PK
1/PK
1/PK
1/PK
1/PK
1/PK
75484
75485
75487
75488
75489
75490
75493
75486
Description Code
GERDXNLE1-A
GEGLXNLE1-A
GEBLXNLE1-A
GEWWXNLE1-27K-A
GEWWXNLE1-30K-A
GEWWXNLE1-35K-A
GEWWXNLE1-40K-A
GEWHXNLE1-50K-A
GEWHXNLE1-65K-A
Colour
Red
Green
Blue
White
White
White
White
White
White
L* Clear light guide viewing angle is 140o
* Clear light guide viewing angle is 140o
umen values are typical. Allow +/- 15% for binning tolerance.
Product Code
10.63
9.45
9.45
9.45
9.45
9.45
9.45
9.45
9.45
Wattsper metre
(light engine)
10.63
9.45
9.45
9.45
9.45
9.45
9.45
9.45
9.45
Watts
per metre(light engine)
C
B
N/A
B
B
B
B
B
B
EEC
C
B
N/A
B
B
B
B
B
B
EEC
25.95
23.06
N/A
23.06
23.06
23.06
23.06
23.06
23.06
EnergyConsumption(kWh/1000h)
25.94
23.06
N/A
23.06
23.06
23.06
23.06
23.06
23.06
EnergyConsumption(kWh/1000h)
62500
62502
Wattsper metre(system)
12.50
11.12
11.12
11.12
11.12
11.12
11.12
11.12
11.12
Watts
per metre(system)
12.50
11.12
11.12
11.12
11.12
11.12
11.12
11.12
11.12
62503
62488
62489
62491
62490
62492
62493
Description Code
GERP
RP
RP
RP
RP
RP
RP
RP
RP
RDXNLE1-A
GEGLXNLE1-A
GEBLXNLE1-A
GEWWXNLE1-27K-A
GEWWXNLE1-30K-A
GEWWXNLE1-35K-A
GEWWXNLE1-40K-A
GEWHXNLE1-50K-A
GEWHXNLE1-65K-A
Colour
Red
Green
Blue
White
White
White
White
White
White
Wavelength/ Colour Temp
625nm
532nm
467nm
2700K
3000K
3500K
4000K
5000K
6500K
Wavelength/ Colour Temp
625nm
532nm
467nm
2700K
3000K
3500K
4000K
5000K
6500K
Viewing
Angle (light engine)
110
110
110
110
110
110
110
110
110
Viewing Angle
(light engine)
110
110
110
110
110
110
110
110
110
Viewing Angle*
(light engine w/ light guide)
330
330
330
330
330
330
330
330
330
Viewing Angle*
(light engine w/ light guide)
330
330
330
330
330
330
330
330
330
Lumens per metre
(light engine)
194
331
75
351
384
410
430
512
472
Lumens per metre
(light engine)
194
331
75
351
384
410
430
512
472
Lumens per metre
(light engine w/ light guide)
154
180
62
230
249
266
279
331
308
Lumens per metre
(light engine w/ light guide)
154
180
62
230
249
266
279
331
308
Lumen values are typical. Allow +/- 15% for binning tolerance.
2438
18
25 28
light engineTetra Contour light engine with light
engine clip
light engine, light guide &
mounting clip
10
10 2811
25
16
13
Typical Dimensions shown are in mm
Performance Data
Light Output
IES and LDT files can be downloaded at www.gelighting.com/eu/led
GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. Tetra Contour Data sheet - 08.2013
This product is intended solely for the use of non-residential architecture lighting and is not intended for use in any other applications.
www.gelighting.com/eu/ledand General Electric are both registered trademarksof the General Electric Company