Top Banner
Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) • Compliance Attack Methods (General) Peak RC
14

Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Dec 14, 2015

Download

Documents

Preston Nelson
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Lead in Agenda (Tracy Rolstad)

• CIP-014 Background (Metcalf)• Compliance • Attack Methods (General)• Peak RC

Page 2: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.
Page 3: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

CIP-014: How Did We Get Here?

Attack Ideas Available on the Internet1/15/2013

Attacks on Critical Infrastructure

Metcalf 4/16/2013

Arkansas 9/16/2013

3

“If someone decides to blast a transformer at its base as prepper Bryan Smith did, and the oil drains out, then the transformer either burns out catastrophically, or if the utility is lucky, a software routine notices the problem and shuts the substation (or at least the affected portion) down” (http://www.bob-owens.com/2013/01/shock-the-system/)

Page 4: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

>120 rounds7.62x39 mm, >51,000 gallons of oil

When seconds matter cops are only minutes away…

Page 5: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Things that make you go Hmmm…

Page 6: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Mk-80 Series Bomb Facts

• 500, 1000, 2000 lb bombs (Mk 82, 83, 84)– About 50% is HE

• Not particularly large compared to a truck bomb• Cratering figures

– Mk 84 (2000 lb)• 50 ft wide by 36 ft deep

Page 7: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Blowing things up is easy!

http://www.nctc.gov/site/technical/bomb_threat.html

2 Severe Bldg damage or collapse3 Skin Penetrating Fragments

Page 8: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Station ~ 2500 ft by 1500 ft (truck bomb)

Page 9: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Care to Name These Events?

19 April 1995Ryder Truck: Ammonium Nitrate& Diesel…roughly 4,000 lbs of homebrew explosive$652 million in damage, 169 dead

26 February 1993Ryder Truck:  1300 to 1500 pounds of nitrate-hydrogen gasCreated a hole 98 feet wide through four levels of concrete.$500 million in damage, 6 dead15,000 ft/sec Propagation speed

Page 10: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Final Analysis of the Threat

• Can a bad person blow up/fault a substation?– YES!

• All at once with a truck bomb? Yes

– There are other methods equally effective• Said methods don’t go bang but do apply faults

• How do you simulate it?– 3 phase faults everywhere…just fault buses

• PRC-023 data is likely relevant• No commsdelayed clearing20 plus cycles?

– You might conclude that modeling relays is a good idea?!

Page 11: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Can we defeat a truck bomb?

• Of course– You make them go some where else…a game of

keep away

Page 12: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Love the Videos

Page 13: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Security on the “down low”

• https://www.youtube.com/watch?v=IEqgZ5tt_Yg

Page 14: Lead in Agenda (Tracy Rolstad) CIP-014 Background (Metcalf) Compliance Attack Methods (General) Peak RC.

Over to Peak RC…