Top Banner
4ZC028 0 0 10 SCALE 1:200 m 20 A A B B Figure 2.13:
1

Layout A0 1-200 - National Grid

Oct 04, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Layout A0 1-200 - National Grid

4ZC028

0010

SCALE 1:200

m20

AA

B

B

Figure 2.13:

AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
I
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
I
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
SUBSTATION MINIMUM ELECTRICAL CLEARANCES IN ACCORDANCE WITH TS 2.1
AutoCAD SHX Text
REF
AutoCAD SHX Text
NOMINAL SYSTEM VOLTAGE (rms)
AutoCAD SHX Text
132kV
AutoCAD SHX Text
400kV
AutoCAD SHX Text
1
AutoCAD SHX Text
PHASE TO EARTH EARTH CLEARANCE
AutoCAD SHX Text
1.1M
AutoCAD SHX Text
2.8M
AutoCAD SHX Text
2
AutoCAD SHX Text
PHASE TO PHASE CLEARANCE
AutoCAD SHX Text
1.4M
AutoCAD SHX Text
3.6M
AutoCAD SHX Text
3
AutoCAD SHX Text
DESIGN CLEARANCE FOR SAFETY (HORIZONTAL) DSH1
AutoCAD SHX Text
2.9M
AutoCAD SHX Text
4.6M
AutoCAD SHX Text
4
AutoCAD SHX Text
DESIGN CLEARANCE FOR SAFETY (VERTICAL) DSH1
AutoCAD SHX Text
3.8M
AutoCAD SHX Text
5.5M
AutoCAD SHX Text
5
AutoCAD SHX Text
INSULATION HEIGHT (PEDESTRIAN ACCESS)
AutoCAD SHX Text
2.4M
AutoCAD SHX Text
2.4M
AutoCAD SHX Text
6
AutoCAD SHX Text
SAFETY DISTANCE (FROM NGC SAFETY RULES)
AutoCAD SHX Text
1.4M
AutoCAD SHX Text
3.1M
AutoCAD SHX Text
7
AutoCAD SHX Text
MEWP DESIGN CLEARANCE FOR SAFETY (HORIZONTAL) DSH2
AutoCAD SHX Text
4.9M
AutoCAD SHX Text
6.6M
AutoCAD SHX Text
8
AutoCAD SHX Text
MEWP DESIGN CLEARANCE FOR SAFETY (VERTICAL) DSH2
AutoCAD SHX Text
5.8M
AutoCAD SHX Text
7.5M
AutoCAD SHX Text
400kV CIRCUIT
AutoCAD SHX Text
132kV CIRCUIT
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
SA
AutoCAD SHX Text
CSA
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
SA
AutoCAD SHX Text
CSA
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
SA
AutoCAD SHX Text
CSA
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
CSA
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
CSA
AutoCAD SHX Text
PI
AutoCAD SHX Text
ESW
AutoCAD SHX Text
CSA
AutoCAD SHX Text
NOTES: 1. ALL DIMENSIONS ARE IN MILLIMETERS. ALL DIMENSIONS ARE IN MILLIMETERS. 2. 400kV CABLES SHALL BE INSTALLED DIRECTLY IN 400kV CABLES SHALL BE INSTALLED DIRECTLY IN GROUND. 132kV CABLES SHALL BE INSTALLED IN TROUGHS 3. THE POSITIONING OF THE NEW TOWER HAS BEEN THE POSITIONING OF THE NEW TOWER HAS BEEN PROSCRIBED BY NATIONAL GRID'S CONTRACTOR. THE POSITION AND EFFECTS OF THIS ON THE TOWER STRUCTURE, FOUNDATIONS OR CONNECTIONS, INCLUDING ADHERENCE TO CLEARANCES HAS NOT BEEN ASSESSED IN ANY WAY BY WSP.
AutoCAD SHX Text
LEGEND: PI - POST INSULATOR - POST INSULATOR POST INSULATOR ESW - EARTHING SWITCH - EARTHING SWITCH EARTHING SWITCH SA - SURGE ARRESTER - SURGE ARRESTER SURGE ARRESTER CSE - CABLE SEALING END - CABLE SEALING END CABLE SEALING END REMOVED EQUIPMENT NEW EQUIPMENT CONSTRUCTION SITE BOUNDARY
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Approved by:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Checked by:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Created by:
AutoCAD SHX Text
Rev:
AutoCAD SHX Text
Sheet(s):
AutoCAD SHX Text
Format:
AutoCAD SHX Text
Scale:
AutoCAD SHX Text
Document Type:
AutoCAD SHX Text
Development Eng:
AutoCAD SHX Text
Document Title:
AutoCAD SHX Text
Scheme Name:
AutoCAD SHX Text
Master Scheme No:
AutoCAD SHX Text
Sub-Scheme No:
AutoCAD SHX Text
Site:
AutoCAD SHX Text
National Grid Document Number:
AutoCAD SHX Text
FEED Document Number:
AutoCAD SHX Text
Rev
AutoCAD SHX Text
App'd
AutoCAD SHX Text
Chk'd
AutoCAD SHX Text
Cre'd
AutoCAD SHX Text
Description
AutoCAD SHX Text
Date
AutoCAD SHX Text
PROPOSED CILFOR SEALING END COMPOUND LAYOUT
AutoCAD SHX Text
PDD-33494-LAY-021
AutoCAD SHX Text
P0
AutoCAD SHX Text
FIRST ISSUE
AutoCAD SHX Text
SV
AutoCAD SHX Text
JO
AutoCAD SHX Text
MR
AutoCAD SHX Text
05.06.19
AutoCAD SHX Text
33494
AutoCAD SHX Text
SNOWDONIA VIP
AutoCAD SHX Text
EAST SITE
AutoCAD SHX Text
P6
AutoCAD SHX Text
SV
AutoCAD SHX Text
05/06/19
AutoCAD SHX Text
JO
AutoCAD SHX Text
MR
AutoCAD SHX Text
James Buckley
AutoCAD SHX Text
LAY
AutoCAD SHX Text
1:200
AutoCAD SHX Text
A0
AutoCAD SHX Text
1 OF 1
AutoCAD SHX Text
05/06/19
AutoCAD SHX Text
05/06/19
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
P
AutoCAD SHX Text
Q
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
P
AutoCAD SHX Text
P
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
EXISTING TOWER 4ZC027
AutoCAD SHX Text
NEW TERMINAL TOWER 4ZC027. SEE NOTE 3.
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
SA
AutoCAD SHX Text
SA
AutoCAD SHX Text
SA
AutoCAD SHX Text
FINISH GROUND LEVEL
AutoCAD SHX Text
TYPICAL DETAIL OF 132kV CABLE INSTALLATION IN CABLE TRUOGH (SCALE 1:20)
AutoCAD SHX Text
P1
AutoCAD SHX Text
CABLE ROUTES CORRECTED, FENCE ADDED, CABLE ROUTES DETAIL ADDED
AutoCAD SHX Text
SV
AutoCAD SHX Text
JO
AutoCAD SHX Text
MR
AutoCAD SHX Text
02.07.19
AutoCAD SHX Text
R
AutoCAD SHX Text
B
AutoCAD SHX Text
Y
AutoCAD SHX Text
B
AutoCAD SHX Text
Y
AutoCAD SHX Text
R
AutoCAD SHX Text
NEW FENCE
AutoCAD SHX Text
NEW FENCE
AutoCAD SHX Text
TROUGH FILLED WITH CBS
AutoCAD SHX Text
ASSOCIATED DRAWINGS: PDD-33494-LAY-022 - PROPOSED CLIFOR SEALING - PROPOSED CLIFOR SEALING PROPOSED CLIFOR SEALING END COMPOUND ELEVATION
AutoCAD SHX Text
2m WIDE PATH AROUND PERIMETER FENCE
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
HEADHOUSE
AutoCAD SHX Text
FINISH GROUND LEVEL
AutoCAD SHX Text
NATIVE SOIL
AutoCAD SHX Text
TYPICAL DETAIL OF 400kV CABLE INSTALLATION DIRECT IN GROUND (SCALE 1:20)
AutoCAD SHX Text
KEY PLAN NTS
AutoCAD SHX Text
P2
AutoCAD SHX Text
OHL MEASUREMENTS ADDED
AutoCAD SHX Text
CM
AutoCAD SHX Text
JO
AutoCAD SHX Text
MR
AutoCAD SHX Text
24.10.19
AutoCAD SHX Text
P3
AutoCAD SHX Text
OHL MEASUREMENT ADDED
AutoCAD SHX Text
CM
AutoCAD SHX Text
JO
AutoCAD SHX Text
MR
AutoCAD SHX Text
04.11.19
AutoCAD SHX Text
P4
AutoCAD SHX Text
TOWER 4ZC027 RELOCATED AS INSTRUCTED BY NG.
AutoCAD SHX Text
MAC
AutoCAD SHX Text
23.01.20
AutoCAD SHX Text
SF
AutoCAD SHX Text
CN
AutoCAD SHX Text
P5
AutoCAD SHX Text
BOUNDARIES UPDATED
AutoCAD SHX Text
HW
AutoCAD SHX Text
03.02.20
AutoCAD SHX Text
SF
AutoCAD SHX Text
CN
AutoCAD SHX Text
P6
AutoCAD SHX Text
DIMENSION ADDED
AutoCAD SHX Text
SPS
AutoCAD SHX Text
17.02.20
AutoCAD SHX Text
SF
AutoCAD SHX Text
CN