Launching MIURA sample prep system

DSP SYSTEMS Information : [email protected] or +31-344-846303 Internet: www.dspsystems.eu

The next generation of automation

Page 2: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

The Full-Automatic Sample Preparation System for dioxins and PCBs analysis has three features…

High Performance Clean-up User-friendly Column Design Unique way of flow switching

Main advantages

Low solvent consumption Hexane 90 ml Toluene 4 ml

Run-time 90 minutes No cross contamination Columns easy to connect and no leakage Competitive prices

Introduction

Page 3: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.
Page 4: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

Availability and Service

• The system is in Europe and several other countries available via DSP Systems as :– GO-2HT capable of running two samples parallel– GO-4HT capable of running four samples parallel– GO-6HT capable of running six samples parallel

• Installation, service and maintenance will be supplied by DSP Systems

• A full maintenance contract is optional with a response time of 24 hours for customers within a radius of 300 km from the middle of the Netherlands and 48 hours within the rest of the EU countries

Page 5: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

General Dioxin method

Sample

Sample extraction or dilution

Clean-up

GC-HRMS or GC-MS/MS

concentration

concentration

spike with 13C labelled standards←

←add Recovery standards

add Control standard←

Required time 1-2 days

Page 6: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

Background --- Features of New System

High performance clean-up

User-friendly column design

Unique way of flow switching without valves

Page 7: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

High performance clean-up 4 columns

Silver nitrate Si column Sulfuric acid Si column Carbon column Alumina column

Heated Purification and elution• Enhances dioxins elution speed• Accelerate a chemical reaction

User-friendly column design … Unique way of flow switching without

valves

Background --- Features of New System

Page 8: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

Clap!

Clap!

Clap!

High performance clean-up User-friendly column design

• Easy applying sample

• Easy connection

• Disposable parts

• No cross contamination

• No washing is required

Background --- Features of New System

Page 9: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

High performance clean-up

① 90 mL of hexane for eluting dioxins and PCBs: i. Trapping dioxins and NO-PCBs on carbon ii. Trapping MO and NDL-PCBs on alumina

② Open the pinch valve

③ Elution PCBs with 1.5 ml of toluene

④ Close the pinch valve and open the other pinch valve

⑤ Elution Dioxins with 1 ml of toluene

Background --- Features of New System

Page 10: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

First resultsRecovery in real samples

Congener Avg Recovery (% ) Stdevn=17

2378- 13C12- TCDF 83,4 10,112378- 13C12- PeCDF 90,4 15,023478- 13C12- PeCDF 95,5 19,3123478- 13C12- HxCDF 81,3 11,4123678- 13C12- HxCDF 84,4 12,9123789- 13C12- HxCDF 79,7 13,3234678- 13C12- HxCDF 83,5 11,21234678- 13C12- HpCDF 81,6 11,51234789- 13C12- HpCDF 85,8 13,8OCDF- 13C12 77,5 14,3

2378- 13C12- TCDD 93,3 12,512378- 13C12- PeCDD 96,3 18,3123478- 13C12- HxCDD 90,9 13,2123678- 13C12- HxCDD 77,6 10,2123789- 13C12- HxCDD 89,3 13,51234678- 13C12- HpCDD 84,6 13,7OCDD- 13C12 87,6 20,2

PCB 77- 13C12 79,2 12,6PCB 81- 13C12 79,4 14,2PCB 126- 13C12 90,5 14,2PCB 169- 13C12 90,1 15,6

PCB 105- 13C12 92,9 14,0PCB 114 13C12 89,8 11,0PCB 118- 13C12 87,5 10,7PCB 123- 13C12 85,5 8,7PCB 156- 13C12 84,4 11,4PCB 157- 13C12 84,6 13,1PCB 167- 13C12 79,6 15,9PCB 189- 13C12 82,7 14,4

PCB 28- 13C12 77,3 15,9PCB 52- 13C12 80,2 11,6PCB 101- 13C12 80,7 11,2PCB 153- 13C12 79,6 12,9PCB 138- 13C12 73,4 13,2PCB 180- 13C12 76,9 14,0

Sample type:

PFADFish oilMix of fatty acidMineralsCompound feed

Page 11: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

First results PeCDD trace peak of interest is 1,2,3,7,8 *1 sample tocopherol

Result after classical clean-up

Result after clean-up using the new system

*1 TEF = 1,0

Page 12: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

First results HxCDF trace peak of interest is 1,2,3,5,7,8; sample tocopherol

Result after classical clean-up

Result after clean-up using the new system

Page 13: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

Conclusion

1.5hrs1 hr

Extraction Purification Measurement

1.5hrs GC-MSMS

GC-HRMS

• Multiple sample extraction• Full Automatic Sample preparation System• GC-MSMS or/and GC-HRMS• High sample Throughput• Eco-friendly analysis• Results available within 8 hours

60mL 100mL

Page 14: Launching MIURA sample prep system DSP SYSTEMSInformation : mail@dspsystems.eu or +31-344-846303Internet:  The next generation of automation.

More information

[email protected]

[email protected]

[email protected]

• Phone : +31-344-846303