G-41 G Laser Scan Micrometer Non-contact, high-speed, high-precision measurement Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice. 50 5 8 170 74 90 70 190 70min 420 Measuring range Center of (measuring point) 70 200 120 60 15 90 ø3.1 8-M3 (Measuring position) 50 22 60 100 11 11 3 70 (Center of measuring point) Cable space 25 15.5 10.5 56 7 35 70 SERIES 544 Laser Scan Micrometer LSM-902/6900 • Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces. • Accuracy of ±0.5μm in the ø0.1 - ø25mm range can be achieved. It is highly suitable suited for pin gage measurement. • Narrow range accuracy of ±(0.3+0.1 D)μm for high precision measurement. • Ultra-high repeatability of ±0.05μm. • The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900). Optional Accessories (Refer to page G-44 for details.) • Standard calibration gage set (ø1.0, ø25.0) : 02AGD180 • Workstage : 02AGD270 • Adjustable workstage : 02AGD280 • Digimatic code output unit (2-ch) : 02AGC840 • 2nd I/O analog interface unit : 02AGC880 • BCD interface unit : 02AGC910 • Printer & cable set (100V AC C-type plug) : 02AGD600A • Printer & cable set (120V AC C-type plug) : 02AGD600B • Printer & cable set (230V AC C-type plug) : 02AGD600C • Printing paper TP411-28CL / 1Pack = 10pcs : 223663 • Digimatic code output cable : 936937 • Foot switch : 937179T SPECIFICATIONS Set Order No. 544-494 544-495* 544-496* Measuring unit Type mm mm inch/mm Applicable standards JIS IEC, FDA Measuring range 0.1 to 25mm (.004 - 1.0") Resolution 0.01 to 10μm (selectable) (.000001 - .0005") Repeatability* 1 ±0.05μm (±.000002") Accuracy* 2 (20°C) Whole range ±0.5μm (±.000020") Small range ±(0.3+0.1 D) [D:mm]* 5 ±(.000012+.001 D) [D:inch] Positional error* 3 ±0.5μm (±.000020") Measuring range* 4 ±1.5×25mm (±0.6x1.0") Scanning rate 800 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 56m/s (2240"/sec) Operating environment Temperature 0 to 40°C Humidity RH 35 to 85% (no condensation) *1: Determined by the value of ±2 ( : standard deviation) when measuring ø25mm at the interval of 1.28 sec. (average 1024 times). *2: At the center of the measuring range. *3: An error due to variation in workpiece position either in the optical axis direction or in the scanning direction. *4: The area given by [optical axis direction]×[scanning direction] *5: D=Difference in diameter between the master gage and workpiece (Unit: mm) Note: To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE. Display unit Display 16-digit plus 11-digit fluorescent display, and guide message LED Segment 1 to 7 (1 to 3, transparent) or 1 to 255 edges Averaging times Arithmetic average: per 1 to 2048/ Moving average: per 32 to 2048 Judgment Selection from "target value + tolerance", "lower tolerance + upper tolerance", or "7 classes multi- limit tolerance zone". Measurement mode Standby, Single measurement, Continuous measurement Statistical analysis Maximum, Minimum, Average, Dispersion, (S.D) External dimensions 335 (W)×134 (H)×250 (D)mm Power supply 100 - 240 V AC ±10%, 50W, 50/60Hz Standard I/F RS-232C, Analog I/O Optional I/F Digimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/F Operating environment 0 to 40°C, RH 35 to 85% (no condensation) Others Nominal setting, sample setting, selection of unnecessary digits, transparent object measurement, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position), zero-set/offset * Measuring unit dual connection, extra-fine line measurement, and some of the communication commands are not available. Unit: mm Measuring Unit External Dimensions Refer to the Laser Scan Micrometer (Catalog No. E13004) for more details. Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC60825- 1 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.
18
Embed
Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction. ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
505
817
0
749070190
70min 420
Measuringrange
Center of (measuring point)70
200 12060
1590ø3.1
8-M3(Measuring position) 50
22
60100
1111 3
70 (C
ente
r of m
easu
ring
poin
t)
Cable space
25
15.5
10.5
567
35
70
SERIES 544 Laser Scan MicrometerLSM-902/6900
•Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces.
•Accuracyof±0.5μmintheø0.1-ø25mmrange can be achieved. It is highly suitable suited for pin gage measurement.
•Narrowrangeaccuracyof±(0.3+0.1 D)μmfor high precision measurement.
SPECIFICATIONSSetOrderNo. 544-494 544-495* 544-496*Measuring unitType mm mm inch/mmApplicablestandards JIS IEC,FDAMeasuring range 0.1to25mm(.004-1.0")Resolution 0.01to10μm(selectable)(.000001-.0005")Repeatability*1 ±0.05μm(±.000002")
opticalaxisdirectionorinthescanningdirection.*4:Theareagivenby[opticalaxisdirection]×[scanningdirection]*5: D=Difference in diameter between the master gage and
Nominal setting, sample setting, selection of unnecessary digits,transparentobjectmeasurement,automaticmeasurement in edge mode, output timer, abnormal dataelimination,SHLchange,groupjudgment,simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection(dimension/position),zero-set/offset*Measuringunitdualconnection,extra-finelinemeasurement,and some of the communication commands are not available.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
G-42
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
Cable space
Measuring range
(Measuring position)
M3, depth 6 (×4)ø3.1, depth 6
55126181
2
1
34324610370min
2532
.5
8440
15.5
10.5 17.5
1111
Working distance
40
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-500S
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
8-M3
42 6453
10.5
15.5
2250
2084
104
57.5
23070min123 3968
34 34*7
10
48 8
18.5
4040
110 40.5 38.5 30
9.5
9.5
14.5
9.5
150
6
40 40
157 73
ø3.1 hole, depth 6(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit Base
Max. 100
Measuring range
Reception Unit
Measuring position
M4, depth 8 (×3) M4, depth 8 (×3)
To Reception Unit(Cable length 0.6m)
ø3.1 hole, depth 6
ø3.1 hole, depth 6
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 0.7kgReception Unit: 0.4kgBase: 0.3kgSignal cable (5m): 0.5kg*7: Extendable up to 66mm.
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-501S
SPECIFICATIONSOrderNo. 544-533 544-534Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.05to10mmResolution 0.01to10μm(selectable)Repeatability*1 ±0.04μm
Accuracy*2(20°C) Whole range ±0.5μmSmall range ±(0.3+0.1 D)μm*3
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1
8-M3
805.
5
10525054.584.5
42 42
70 min
170 5580 50*7
88
482594857202
6
18.5
5022
10.5
15.5
9.5
9.5
14.5
9.5
415790
12 11090
20
10
30
355
46
53 6842
95.5 65.5
150
57.5
130
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 350
Measuring range
Measuring range
Reception Unit
Base
M4, depth 8, ø3.3 through hole (×3)For mounting side plate (same in the back)
M4, depth 8, ø3.3 through hole (×2)For mounting side plate (same in the back)
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3)For mounting base
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3)For mounting base
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 1.1kgReception Unit: 0.6kgBase: 0.5kgSignal cable (5m): 0.5kg*7: Extendable up to 270mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-503S
SPECIFICATIONSOrderNo. 544-535 544-536Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.3to30mmResolution 0.02to100μm(selectable)Repeatability*1 ±0.11μmAccuracy*2
(20°C)Whole range ±1.0μmSmall range ±(0.6+0.1 D)μm*3
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
12-M3
ø3.1
15.5
10.5
110*716388
192348
66
20
60
42
4218
.5
90 360 90
2250
100
58 70
7
258 102
540
185 82
70min
2011
013
0
12
115.5 71
797
168.587 87
42
14.5
9.5
162 174.5 121 63
9.5
9.5
273
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 700
Measuring range
Measuring range
Reception Unit
Base
M5, depth 10, ø4.2 through hole (×3)For mounting side plate (same in the back)
M5, depth 10, ø4.2 through hole (×2)For mounting side plate (same in the back)
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3)For mounting base
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3)For mounting base
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 1.4kgReception Unit: 0.8kgBase: 0.8kgSignal cable (5m): 0.5kg*7: Extendable up to 537mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-506S
•Narrowrangeaccuracyof±(1.5+0.5 D)μminfor high precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec. Suitable for high speed lines or in applications
subjecttovibration.
SPECIFICATIONSOrderNo. 544-537 544-538Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to60mmResolution 0.05to100μm(selectable)Repeatability*1 ±0.36μmAccuracy*2
(20°C)Whole range ±3μmSmall range ±(1.5+0.5 D)μm*3
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
8-M4
ø3.1
312 88
48
7
48
146
9
146
9
200100
521379696 263
8068
18.5
4816
230
192
84
99131*7190
700107321272
238462
70 min
19
819
8
85144256192
198
150400150
120
30
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 700
Measuring range
Measuring range
Reception Unit
Base
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12 (×3)For mounting base
M6, depth 12 (×3)For mounting base
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
ø3.1, depth 6 (Reference hole)
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 3.0kgReception Unit: 1.2kgBase: 1.8kgSignal cable (5m): 0.5kg*7: Extendable up to 510mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-512S
SPECIFICATIONSOrderNo. 544-539 544-540Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to120mmResolution 0.1to100μm(selectable)Repeatability*1 ±0.85μmAccuracy*2 (20°C)
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1 (Measuring position)8-M4
84110 10
841
9 9
378
170 110600350 250
9
200100
120
100
7420
.5
880320 160400
8.7200 200
8.7
224
2524
9
206 87.5360520
306107100
40
200400 13 13688218
160
208
208
Min. 70
Cable space
Measuring range
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12 (×3)For mounting base
M6, depth 12 (×3)For mounting base
Measuring position ø3.1 hole, depth 6(Reference hole)
Note1: Distance between emission unit and reception unit: 400mm to 800mm
Note1
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-516S
Suitable for high speed lines or in applications subjecttovibration.
SPECIFICATIONSOrderNo. 544-541 544-542Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to160mmResolution 0.1to100μm(selectable)Repeatability*1 ±1.4μmAccuracy*2 (20°C)
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
Unit:mmDIMENSIONS
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1 (Measuring position)
12-M3
Measuring range
80Ca
ble
spac
e18
0
11
25
60
98
1005022
647
60
120
1011 882365
52.540
382 85180
528
202
11
10.5
15.5
1010
0
10150
83 97
100 100
172 13.5
SERIES 544 Laser Scan Micrometer (Display Unit Integrated Model)LSM-9506
•Highaccuracyof±2.5μm,integrateddisplayunitwithmanyfunctionsequivalenttothemulti-functiondisplay unit.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
Nominalsetting,samplesetting,selectionofunnecessarydigits,transparentobjectmeasurement*2, measurement of odd fluted parts, automatic measurement in edge mode, output timer, abnormal data
*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.
Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller range, contact your local Mitutoyo sales office.*TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,Ffor
SAA,KforKC,CandNosuffixarerequiredforPSE.** Cannot be connected to 544-495, 544-496.** Previous models such as 544-451 cannot be connected.
Unit:mmDIMENSIONS
G-50
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Panel-mount Type Display Unit)LSM-5200
•Acompactcontrollerwhichcouldbeusedformulti-unit system configurations.
Measurement of odd fluted parts, simultaneous measurement, nominal setting, sample setting, selection of unnecessarydigits,transparentobjectmeasurement*2
Automaticworkpiecedetection(dimension/positiondetected)*1, abnormal data elimination, mastering, statistical processing(whenusingUSB,RS-232C),outputtimer,automaticmeasurementinedgemode,presetting
Note that every function is limited in its combination possibilities. See the user manual for details.Mass 1.4 kg
*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.
Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office.*3:DC24Vexternalpowersupply(commercialitem)isrequiredseparately.Note 1: Cannot be connected to 544-495, 544-496.Note2:Previousmodelssuchas544-451 cannot be connected.Note3:ForUSBcommunicationwithaPC,adedicateddevicedriverisrequired.Fordetails,contactyourlocalMitutoyosalesoffice.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefi t of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specifi cation without notice.
Sample Screen Measurement ExamplesPrinter roll multi-point simultaneous measurement
variety of measuring systems to be constructed.•Capableofprocessingamaximumof10channelsofmeasurementdata(USB-HUBconnection).•CapableofCalculation between channels, statistical analysis, fi le output of calculation results.•Variousdisplayfunctionssuchascounterdisplay,graphdisplay,andcalculationresultareequipped. *RefertopageG-50forspecificationsofLSM-5200.
SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories
544-047
544-531, 532
LSMPAK
Commercially available products, such as USB hubs and cables, areavailable for connecting to the display unit.
Applicablemodels Display unit: 544-047(Ver.1.004Aorlater)Measuring unit: 544-531, 532 series
Display function Max.12windows(counter,meter,chart,overalljudgment)
Setup function Presetting,dataoutput,samplemeasurement,resolutionselect,judgmentsetting,measurementofodd number fluted parts, simultaneous measurement *Each function has its combination limit.
Measurement function Single, continuous measurement, single automatic repetitionCalculation function Arithmeticoperation,maximum,minimum,range,average,total(anycombinationavailable)GO/NGjudgment 3-step(–NG,GO,+NG)Interface USB2.0(Hi-Speedcommunicationrecommended)Maximumconnection 10units
Operatingenvironment (PC)
OS WindowsXP,7(32-bit)CPU Pentium4,2GHzorbetterrecommendedMemory 1GB or moreHDD free space 500MBormoreDisplay 1024×768dot,TrueColor(32-bit)ormorerecommended
G-52
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories
•Standard cylinder gage set suitable for calibrationofLaserScanMicrometers.
•Nominalgagediameters(1to160mm)areasgiven in Specifications.
Standard calibration gage set
Installationexample(LSM-902)
•Easy set-up and height adjustmentenableshigh-precisionmeasurement.
Workstage
•Pin gage or plug gage•Rollerofcopyingmachine
Measurement Examples
•Vertical/horizontalslidemechanismenableseasymeasurement of various workpiece diameters.
* The stop is not included in the basic set for 544-537, 544-538, 544-115, 544-116. •Optionalpartfortheadjustableworkstage,suchascentersupport,adjustableV-block(up/down)etc.,areavailable.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories
•Usedforsupportingmeasurementofoutsidediameter of fine wirelike materials such as magnetic wire or fiber.
Guide pulley
•Airblowsfromtheairoutletinstalledonthelasersection to clear dust adhering to the laser window.
Air shield
•Extensionsignalcablesarenecessarywhenthemeasuringunitanddisplayunitareseparatedinoperation;Extensionrelay cables are necessary when the optical section is separated in operation.
Extension signal cable / Extension relay cable
SPECIFICATIONSModel 544-531, 544-532 544-533, 544-534OrderNo. 02AGD200 02AGD210Each measurement range is as follows:544-531, 544-532:ø5μmtoø1.6mm544-533, 544-534:ø50μmtoø2mm
For calibration, the calibration gage set for 544-531, 544-532(02AGD110)isrequired.
Relay cable, 1.4m(0.6m for 544-533, 544-534) Not equipped with 544-531, 544-532 (and 544-495, 544-496 )
Extension relay cable
Signal cable (5m) No.02AGN770A
Display unit
Emission Unit
Reception Unit
SPECIFICATIONSExtension signal cable Extension relay cableOrderNo. Cable length OrderNo. Cable length02AGN780A 5m 02AGC150A 1m02AGN780B 10m 02AGC150B 3m02AGN780C 15m 02AGC150C 5m02AGN780D 20m* For 544-531, 544-532 and 544-533, 544-534theallowablemaximumlengthforsignalcableis20m;relaycableis2m.* For 544-535, 544-536, 544-537, 544-538, 544-539, 544-540 and 544-541, 544-542theallowablemaximumlengthfor
signalcableis30m;relaycableis5m.*Themaximumextensionlengthofthesignalcableandrelaycableis32mintotal.* Cannot be used with 544-495, 544-496.
G-54
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
•Measurementdatacanbeprinted.
SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
G-56
G
■ CompatibilityYourLaserScanMicrometerhasbeenadjustedtogetherwiththeIDUnit,whichissuppliedwiththemeasuringunit.TheIDUnit,whichhasthesamecode number and the same serial number as the measuring unit, must be installedinthedisplayunit.ThismeansthatiftheIDUnitisreplacedthemeasuring unit can be connected to another corresponding display unit.
■ The workpiece and measuring conditionsDepending on whether the laser is visible or invisible, the workpiece shape, and the surface roughness, measurement errors may result. If this is the case, perform calibration with a master workpiece which has dimensions, shape, and surface roughness similar to the actual workpiece to be measured. If measurement values show a large degree of dispersion due to the measuring conditions, increase the number of scans for averaging to improve the measurement accuracy.
■ Electrical interferenceTo avoid operational errors, do not route the signal cable and relay cable oftheLaserScanMicrometeralongsideahighvoltagelineorothercables capable of inducing noise current in nearby conductors. Ground all appropriate units and cable shields.
■ Connection to a computerIftheLaserScanMicrometeristobeconnectedtoanexternalpersonalcomputerviatheRS-232Cinterface,ensurethatthecableconnectionsconform to the specification.
■ Re assembly after removal from the baseObserve the following limits when re assembling the emission unit and reception unit to minimize measurement errors due tomisalignment of the laser's optical axis with the reception unit.
■ Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright,areattachedtotheLaserScanMicrometers as is appropriate.
Laser Scan Micrometers Quick Guide to Precision Measuring Instruments
a. Parallel deviation between reference lines C and D: X(inthetransversedirection)
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
G-57
G
■ Measurement Examples
Diameter
Dia.
Out of roundness
Reference edge
Reference edge
Reference edge
Reference edge
Gap
In-line measurement of glass fiber or fine wire diameter
Measurement of outer diameter of cylinder
Measurement of outer diameter and roundness of cylinder
X- and Y-axis measurement of electric cables and fibers
Measurement of thickness of film and sheet
Measurement of spacing of IC chip leads
Measurement of film sheet thickness
Measurement of laser disk and magnetic disk head movement
Measurement of gap between rollers
Measurement of tape width
Measurement of outer diameter of optical connector and ferrule
Measurement of form
Dual system for measuring a large outside diameter
G-58
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.