CLIENT REVISION DETAILSREVISION / DATE DATE OF SURVEY SURVEY BY DRAWN BY APPROVED BY
ORIGIN OF LEVELS
CONTOUR INTERVAL
ORIGIN OF COORDS
DRAWING TITLE SCALE
REVISION
SHEET
REF
Catholic Education Office -Diocese of Parramatta
01.05.2018
SSM 137580 RL 64.79 (AHD)
SSM 137580
0.5m
PLAN SHOWING DETAIL AND LEVELS OVERLOT 2 DP 579138 & LOT 5 DP 1057912
No. 24 EVANS ROAD, ROOTY HILL
1:1000 @ A1
10505_DET_1A
A1 OF 4
A 14.05.2018 AS SURVEYED ON SITE PK RS PK
INTERESTS RELATING TO THE SUBJECT SITE:The Certificate of Title for Lot 2 DP579138 ordered on 29.03.2018& Lot 5 DP 1057912 ordered on 4.05.2018 identified thefollowing interests (refer to the original 88B Instrument orDealing creating the interest for specific terms - we recommendthis be undertaken prior to design or construction):Lot 2 DP579138·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·G773192 Covenant affecting part ~ (Not investigated).·P633156 Covenant ~ (Not investigated).·DP1137984 Easement for Padmount Substation 2.75 metre(s)
wide affecting the part(s) shown so burdened in DP1137984(Denoted (A) in this plan).
DP1137984 Restriction(s) on the use of land affecting the part(s)shown so burdened in DP1137984 (Denoted (B) in this plan).·AH309127 Positive Covenant ~ (Not investigated).·AH309128 Restriction(s) on the use of land ~ (Not investigated).
Lot 5 DP1057912·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·DP265736 Easement for drainage 1 wide appurtenant to the
land above described (remote to site - not shown).·DP1057912 Easement for drainage of water 1.5 metre(s) wide
appurtenant to the land above described (Denoted (C) in thisplan).
·DP1057912 Restriction(s) on the use of land referred to andnumbered 8 in S.88B instrument ~ (Not investigated).
NOTES·Do not scale from this plan.·The purpose of this Detail Survey plan is to show detail and
levels for planning and design. Do not use the informationshown for any other purpose.
·Plan coordinates have been determined from ground (real)distances and are related to an MGA (grid) point of origin. Ascale factor must be applied to convert plan coordinates to trueMGA grid coordinates.
·Contours are an indication of the topography and should only beused for planning purposes. Spot levels only should be used fordetailed design.
·A preliminary fixation of subject site boundaries has been made.Boundary dimensions and areas have been compiled from thecurrent subject site Deposited Plan. If any work is to beundertaken on or adjacent to a boundary then a BoundarySurvey is recommended to define the boundaries of the site.
·The relationship of built form and natural features to boundariesis diagrammatic and if critical should be confirmed by aBoundary Survey. Boundary setbacks (if shown) are approximateonly.
·Building and feature descriptions are to be used for generalidentification purposes only and may require furtherinvestigation.
·No services search has been undertaken. Only those servicesvisible at the time of survey have been located. It isrecommended to contact Dial Before You Dig and the relevantservice authority prior to commencement of any work.
·Only those windows visible and unobscured from within thesubject property on the date of survey have been located.
·Tree information and canopy location is approximate (and notnecessarily symmetrical) and if critical may require furtherassessment.
·The DWG format file for this plan is integral and containsadditional spatial information not able to be displayed in thePDF file.
·This drawing and the information it contains is copyright andremains the property of SurveyPlus Pty Ltd. It must not becopied, used or altered without the express authority ofSurveyPlus.
·These notes and interests noted in the Certificate of Title forman integral part of this plan and must not be erased.
0m 10 20 100
505
SCALE 1:1000 @A1
SITE PLAN
ETET
ETET
65.83
65.83
66.96
67.19
67.00
65.20
68.02
68.56
67.01
67.02
65.9165.69
65.76
66.54
67.03
67.73
66.86
67.93
68.56
67.23
65.83
67.0265.82
65.78
65.90
67.19
66.13
67.74
66.20
65.05
65.89
66.56
66.15
69.85
72.91
72.72
68.8271.36
71.3670.98
71.06
71.82
71.78
71.73
71.78
70.53
73.3373.33
73.33
70.14
70.00
68.8868.29 68.31
68.93
68.98
68.61
68.9069.10
69.76
69.75
71.7471.75
71.81
70.37
70.42
70.12
69.90
70.08
70.27
69.86
69.34
68.86
67.99
69.33 69.1369.12
69.0470.15
70.35
70.3570.55
70.56
70.76
70.7070.69
70.40
71.06
70.59
70.3370.53
70.74
70.74
70.93
70.93
71.1371.15
70.08
70.08
70.0470.45
72.00
72.04
71.4271.43
71.9071.84
64.98
67.27
67.68
67.90
67.23
67.15
64.89
69.04
67.29
67.95
66.7366.13
65.44
67.27
67.83
67.54
65.79
66.31
65.44
65.18
65.45
67.90
66.58
67.20
69.07
69.06
68.45
67.63
67.40
66.77
65.61
67.40
65.71
67.71
64.99
65.54
64.97
67.61
66.71
65.80
68.44
67.50
66.24
65.07
66.24
67.28
66.48
72.61
72.7872.64
72.82
73.04
73.05
66.28
68.16
68.20
68.29
68.20
70.16
67.84
67.70
67.41
67.2767.70
67.97
68.26
68.44
68.64
68.9569.91
70.20
70.77
71.1071.35
71.51
71.88
72.0772.24
72.45
72.73
72.13
72.11
72.0672.07
72.1372.10
72.18
72.19
72.4072.40
72.43
72.46
72.31
72.30
72.39
72.36
72.55
72.56
72.65
72.65
68.8568.84
68.83
68.74
68.68
68.84
67.71
67.70
68.43
68.47
68.49
69.1269.10
69.78
69.77
70.4070.38
70.30
69.91
69.40
68.82
67.53
67.36
67.26
66.43
66.23
66.87
68.06
67.57
67.17
69.6069.55
69.51
69.34
69.28
69.36
69.0269.03
70.61
70.76
69.06
71.05
71.53
71.63
70.02
70.10
72.48
71.4371.24
71.27
68.85
68.86
67.78
70.50
70.53
69.9269.01
70.96
66.46
67.72
66.81
67.11
65.50
67.78
67.14
66.57
66.34
67.09
66.60
65.28
66.99
66.37
67.17
67.57
67.67
65.05
65.56
67.64
65.75
67.17
66.01
67.0967.08
66.73
64.57
68.74
68.45
72.93
72.96
72.88
69.0368.9568.6869.54
69.86
70.1071.02
70.77
70.54
71.51
71.75
71.80
70.7170.23 69.46
68.75
68.53
68.56
67.90
69.81
68.86
69.46
69.89
67.97
67.99
69.77
69.8569.76
71.00
71.19
71.54
71.4571.30
71.17
71.15
70.83
70.04
70.08
70.10
66.38
67.00
67.00
67.46
66.66
66.4467.08
66.26
66.87
67.37
67.76
66.27
66.71
67.26
66.4967.06
67.10
67.55
67.63
66.46
66.42
67.00
72.82
73.21
72.83
72.63
72.4972.33
72.1971.65
71.37
71.08
70.79
70.5270.22
69.9569.69
69.4269.15
68.9068.06
67.8067.52
67.2867.02
66.79
66.5666.38 66.92
66.65
66.85
67.1167.33
67.08
67.32
67.57
67.80
67.57
67.83
68.04
68.30
68.0868.34
68.5268.80
68.5868.82
69.13
69.3669.08
69.33 69.60
69.8469.60
69.85
70.10
70.3770.12
70.37
70.63
70.9070.63
70.90 71.16
71.40
71.16
72.06
71.9172.13
72.25
72.46
72.37
67.44
67.39
68.0468.0267.34
67.20
67.29
67.43
67.48
67.74
67.94
67.08
66.8067.12
67.92
67.8567.05
66.92
67.7667.65
66.82
66.75
67.53
67.4066.67
66.63
72.79
72.79
72.79
72.79
71.4671.46
71.46
71.46
70.4170.41
70.4169.30
69.3068.32
68.3268.32
68.3268.32
68.32
68.32
68.20
68.25
72.89
72.83
72.87
72.63
72.23
71.63
71.22
70.25
69.25
68.20
71.68
71.37
70.96
65.16
66.00
64.56
71.99
64.70
66.29
65.35
67.35
68.14
65.8665.67
64.49
71.97
65.50
64.52
66.06
66.21
66.15
68.22
66.11
65.27
66.08
64.99
66.23
65.46
66.18
68.2972.13
67.21
65.8265.72
64.35
71.88
65.45
65.99
69.2864.62
66.24
66.22
64.5965.97
66.13
65.3366.15
65.30
68.43
65.70
71.78
65.75
64.40
71.71
65.65
66.33
69.42
68.17
66.10
65.05
65.23
70.3970.53
71.5771.43
72.91
72.75
73.08
73.04
73.18
73.26
73.1473.24
73.29
73.14
73.24
73.37
68.63
68.74
68.63
68.49
73.03
72.91
72.9673.11
73.1072.9772.99
72.84
72.64 72.80
72.76
72.60 72.71
72.8371.94
71.8371.6671.78
71.7171.52
71.46
71.65
71.64
71.77
71.3371.21
69.15
69.03
66.80
66.66
66.40
66.36
65.94
70.57
70.63
70.49
70.42
65.84
67.87
65.85
65.86
72.09
68.63
68.61
69.65
70.72
69.6670.09
70.09
71.19
71.72
72.27
71.36
70.12
69.11
72.34
72.31
72.35
66.97
66.71
67.9967.75
66.7967.70
68.09
69.58
69.22
68.7168.43
68.27
68.6468.40
68.17
67.99
67.56
69.64
69.39
68.79
70.82
71.42
73.0470.28
70.64
70.8370.85
66.45
67.29
64.90
67.79
66.48
67.84
69.4570.15
67.09
67.16
68.80
67.24
67.23
67.16
70.69
72.40
65.6565.56
66.45
70.04
67.90
71.91
66.86
68.43
67.94
67.94
68.75
68.8368.84
70.52
70.51
70.5370.52
72.14
72.14
71.97
71.7171.88
71.83
FL 68.90
FL 71.81
FL 71.76
FL 68.06
FL 71.72
FL 70.23
71.40
67.96
67.90
71.65
71.71
71.66
72.13
73.65
R 78.51
R 70.02
R 77.04
R 75.06
R 70.95
R 70.28
R 78.43
R 77.87
R 74.84
R 74.98
R 75.64
R 76.06R 78.43
R 77.91
R 78.40
R 78.40 R 78.42
R 78.57
R 78.57
R 77.93
R 77.90
R 75.54
R 77.03
R 76.99
R 77.85
R 76.22
G 68.92
G 75.55
G 74.59
G 77.43
G 74.60
G 76.22
G 68.91
G 76.25
G 74.81
G 74.60
G 74.57
G 75.55
G 76.65
G 77.97
G 77.97
G 75.3266.90
67.1867.62
66.77
67.31
67.23
67.28
68.87
67.05
67.34
67.12
68.50
66.44
67.34
67.20
67.61
68.44
68.76
68.85
68.89
68.84
72.15
72.14
72.14
72.25
70.30
72.14
67.76
71.05
70.82
70.0971.05
66.19
66.50
65.81
66.43
66.10
65.53
65.74
69.0569.07
64.64 66.39
66.40
72.8472.84
70.45
70.49
68.83
68.6968.73
69.3569.34
69.29
70.7570.86
71.56
70.89
71.22
71.35
71.74
71.84
71.81
71.90
71.94
72.61
72.58
72.57
72.61
72.3272.35
72.4172.43
72.39
72.41
73.03
72.81
70.60
65.80
67.28
67.37
66.05
68.22
69.15
66.28
67.05
65.62
65.93
66.27
65.67
66.43
66.38
66.45
66.97
65.64
66.09
67.45
67.23
65.99
66.83
66.93
65.79
65.87
65.58
67.20
67.93
66.77
65.48
65.55
65.58
66.78
66.02
65.58
66.46
72.95
67.15
67.50
67.72
67.43
67.57
67.42
68.02
68.36
68.97
69.63
70.34
70.35
69.04
69.77
70.48
71.42
72.33
72.88
72.83
72.61
65.55
65.68
67.04
65.53
65.41
67.73
65.68
66.43
65.60
65.40
65.51
65.86
72.14
71.71
71.8271.89 71.78
71.72
T-S4D0.4H14
T-S2D0.3H11
T-S5D0.5H11
T-S3D0.4H13
T-S3D0.3H9
T-S2D0.3H9
T-S2D0.4H9T-S2D0.3H12
T-S4D0.4H12
T-S2D0.3H9
T-S7D0.6H25
T-S3D0.4H9
T-S4D0.5H112TRUNKS
T-S2D0.2H8
T-S4D0.4H13
T-S4D0.4H13
T-S5D0.5H20
T-S4D0.3H14
T-S2D0.2H10
T-S3D0.4H10
T-S7D0.7H25
T-S3D0.3H13
T-S3D0.5H10
T-S2D0.2H9
T-S4D0.5H14
T-S2D0.2H6T-S4D0.5H20
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LIN
E
M
ARKI
NG
LIN
E
M
ARKI
NG
LIN
E
M
ARKI
NG
LIN
E
MAR
KIN
G
LIN
E M
ARKI
NG
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING
LINE MARKING LIN
E
M
ARKI
NG
LIN
E
M
ARKI
NG
LIN
E
M
ARKI
NG
LIN
E
M
ARKI
NG
T-S3D0.5H11
LIN
E M
ARKI
NG
SINGLE STOREYWEATHERBOARD BUILDING
TILE ROOF
BRICKSH
ED
2 STOREYBRICK BUILDING
METAL ROOF
VERANDAH
SEATSEAT
SEAT
CONCRETECONCRETE
SEAT SEAT SEAT
SEAT SEATCONCRETE
SEAT
SEAT
CONCCONCRETE
3 STOREYBRICK BUILDINGMETAL ROOF
W1W2
W3
W5
W7
W9
W10
BRIC
K
WAL
L
W11W12
CONC
RETE
PATH
CONC
RETE
SEAT
SEAT
SEAT
D1
D2
VERA
NDAH
W13D3
D4
D5
D6D7
RAIL
RAIL
COL
W14
W15
TTPITx2
T
TPIT T
CONCRETE
CONC
RAIL
UPRIGHT
KERB
CONC
RAIL
RAIL ED
GE
BIT
OF
RAIL
RAMP
GARDEN
RAIL STEPSRAIL
RAILRAILRAIL
D12
W79
BRIC
K
WAL
L
STEE
L
STEEL PICKET FENCE
W77 W76SIP
W75D21W73 W71 W69
BRICK WALL
CONC
STEPCONCRETE
RAIL
W20
W26
W32
D10
BRICK
W30
W31
EPIT
D20
W66W67W68
WIRE MESH FENCE
CONCW35W34
W38W37
D13W40W218
T
EPIT
SIP
CON
C
COL
COL
COL
CONC
RETE
CON
CRET
EBL
OCK
WAL
L
CON
CRETE
SIP
STW GRATESL 65.75IL 65.04
CONCRETE
EDGE
OF
BITU
MEN
STW GRATESL 66.01IL 65.41
STW GRATESL 68.13IL 66.50
STW GRATESL 67.88IL 66.68
STW GRATESL 69.00IL 68.75 STW GRATE
SL 69.07IL 68.78
CONC
D15
CONCRETE
LP
LP
LP
EDG
E
SOFTFALL
OF
BOTT
OM
OF
BANK
STW GRATESL 66.34IL 65.63
TOP
OF
BANK
TPITx2T T
UPRIGHT CONCRETE KERB
SISISISI
TPITT
CONC PATH
WALL
HIGH
BEN
D
WIR
E
M
ESH
F
ENCE
STEEL PICKETFCE
CONCRETE DRIVEWAY
CONCRETE PATH
PP
PP
CONC PATH
UPIT U
SI
KERB
CON
C
UPRIGHT
STW GRATESL 66.02IL 64.62
STW GRATESL 65.76IL 65.55
STW GRATESL 65.97IL 65.79
HIGH
FENCESTEEL PICKET
SI
CON
C KE
RB
CONCRETE
CONCRETE
LPLP
UPRIGHT
LP
UPR
IGH
T
STW GRATESL 68.50IL 67.39
CONC
KERB
LP
LP
HIG
H
FCE
PICK
ETST
EEL
LINE MARKING
CON
CRETE
LP
CONC
CONC
SEAT
SEATCO
NC
T-S4D0.5H14
SEAT
CONC
BOT
OF RET
WALL
STEE
L
FENC
E
PICK
ET
TPITT
RAIL
RAILCONC PATH
RAILRAIL
STW GRATESL 67.10IL 65.96
COL
SINGLE STOREYBRICK BUILDING
TILE ROOF
UPR
IGH
TW
IRE
FEN
CE
MES
H
LPLP
UPR
IGH
T
STW GRATESL 71.96IL 71.00
CONC
KERB
CONC
KERB
CON
CU
PRIG
HT
CON
C
LP
W17D8
W18
W19
W21W22
W23
W24
W25W27
W28
D9
W33
RAMP
WALL
D11
W41CONC
W43
STW GRATESL 70.67IL 70.52
W44W46W47 D16 W49
W48
W50D17
W52W51
W53
W55W54
W56
D18 W58W57
W59
W60
STW GRATESL 72.79IL 72.52
RAIL
EPIT
STW GRATESL 70.07IL 69.93
HYD H
HYD H
HHHYDx3
H
WMHIGH
STW GRATESL 66.90IL 65.79
STW GRATESL 65.71IL 64.77KIO
SK
STW GRATESL 65.41IL 64.84
STW PITSL 65.38
FCEPICKETSTEEL
CON
C
HIG
HFE
NCE
PICK
ETST
EEL
WALL
BLOCK
EDGE
BOL
BOL
BITO
F
COL
SIPx2
EDGE O
FBIT
BRICKW
ALL
STEPSWALL
W29
LAP
FENCE
AND
PALING
CAP
CON
C
PIPE
EDG
EOF
CON
CRETE
SOFTFALL
UPRIGHT
FLAG
KERBCONCRETE
UPRIGHT
KERBCO
NC
STEE
L
FEN
CE
PICK
ET
LP
UPRIGHT
KERB
CON
C
EDG
E
OF
SOFT
FALL
BRICK
RET
WAL
L
STW GRATESL 68.76IL 68.66WAT
W
STW GRATESL 68.78IL 68.67
FEN
CE
RWTSTW GRATE
SL 69.78IL 69.38
WALL
RAIL
TPIT
STW GRATESL 70.51IL 70.41
STW GRATESL 70.49IL 70.38
STEEL PICKET FCE
W8
W6
W4
W36W39W42
WAL
L
W45
BLOCKCONC WALLSTEP
BLOCKWALL
WAL
L
SIP
W78 W74 W72 W70
FEN
CE
BLO
CKW
ALL
COL
2DP 579138
1.917ha(BY DP 579138)
STEEL PICKET
FEN
CE
STATUE
BENCHMARKBOLT IN KERBRL 66.04m (AHD)
EVANS ROAD
24DP 24250
1DP 1073750
26DP 211725
25DP 211725
240° 27' 20"95.135
150°
27'
20"
40.2
1
156°
48'
00"
~ 5
4.29
327° 29' 50" ~ 76.415
5.03513° 5
8' 20"
CON
C
STATUE
COL
65
66
67
68
69
70
71
72
73
73
W16
FLAG
KERB
FEN
CEPI
CKET
BRIC
KW
ALL
(A)
STATUE
(B)
N N
MGA
(BY D
P 10
5791
2)M
AGNETIC
(BY D
P 579
138)
LEGEND
- Sewer Inspection Pit
ET - Overhead Comms/Electricity Wires
COL - ColumnEPIT - Electrical Pit
HYD - Hydrant
LI - LightLP - Light Pole
RWT - Top of Retaining WallSI - SignSIP
SMH - Sewer Manhole
- Telecommunication PitTPIT- Unknown PitUPIT
- Water MeterWM- Water PointWAT
PP - Power Pole
STW - Stormwater
G XX.XX - Gutter RL XX.XX
R XX.XX - Ridge/Roof RL XX.XX
IL XX.XX - Invert Level RL XX.XX
- Surface Level RL XX.XXSL XX.XX
BOL - Bollard
FL - Floor LevelE
H
S
T
U
W
CLIENT REVISION DETAILSREVISION / DATE DATE OF SURVEY SURVEY BY DRAWN BY APPROVED BY
ORIGIN OF LEVELS
CONTOUR INTERVAL
ORIGIN OF COORDS
DRAWING TITLE SCALE
REVISION
SHEET
REF
Catholic Education Office -Diocese of Parramatta
01.05.2018
SSM 137580 RL 64.79 (AHD)
SSM 137580
0.5m
PLAN SHOWING DETAIL AND LEVELS OVERLOT 2 DP 579138 & LOT 5 DP 1057912
No. 24 EVANS ROAD, ROOTY HILL
1:200 @ A1
10505_DET_1A
A
A 14.05.2018 AS SURVEYED ON SITE PK RS PK
40m 2 1510 201 3 5
SCALE 1:200 @A1
2 OF 4
T-S8D0.5H14
TREE DIAGRAM
Approx.Tree Height
Trunkdiameter
Approx. TreeRadius Spread
INTERESTS RELATING TO THE SUBJECT SITE:The Certificate of Title for Lot 2 DP579138 ordered on 29.03.2018& Lot 5 DP 1057912 ordered on 4.05.2018 identified thefollowing interests (refer to the original 88B Instrument orDealing creating the interest for specific terms - we recommendthis be undertaken prior to design or construction):Lot 2 DP579138·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·G773192 Covenant affecting part ~ (Not investigated).·P633156 Covenant ~ (Not investigated).·DP1137984 Easement for Padmount Substation 2.75 metre(s)
wide affecting the part(s) shown so burdened in DP1137984(Denoted (A) in this plan).
DP1137984 Restriction(s) on the use of land affecting the part(s)shown so burdened in DP1137984 (Denoted (B) in this plan).·AH309127 Positive Covenant ~ (Not investigated).·AH309128 Restriction(s) on the use of land ~ (Not investigated).
Lot 5 DP1057912·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·DP265736 Easement for drainage 1 wide appurtenant to the
land above described (remote to site - not shown).·DP1057912 Easement for drainage of water 1.5 metre(s) wide
appurtenant to the land above described (Denoted (C) in thisplan).
·DP1057912 Restriction(s) on the use of land referred to andnumbered 8 in S.88B instrument ~ (Not investigated).
NOTES·Do not scale from this plan.·The purpose of this Detail Survey plan is to show detail and
levels for planning and design. Do not use the informationshown for any other purpose.
·Plan coordinates have been determined from ground (real)distances and are related to an MGA (grid) point of origin. Ascale factor must be applied to convert plan coordinates to trueMGA grid coordinates.
·Contours are an indication of the topography and should only beused for planning purposes. Spot levels only should be used fordetailed design.
·A preliminary fixation of subject site boundaries has been made.Boundary dimensions and areas have been compiled from thecurrent subject site Deposited Plan. If any work is to beundertaken on or adjacent to a boundary then a BoundarySurvey is recommended to define the boundaries of the site.
·The relationship of built form and natural features to boundariesis diagrammatic and if critical should be confirmed by aBoundary Survey. Boundary setbacks (if shown) are approximateonly.
·Building and feature descriptions are to be used for generalidentification purposes only and may require furtherinvestigation.
·No services search has been undertaken. Only those servicesvisible at the time of survey have been located. It isrecommended to contact Dial Before You Dig and the relevantservice authority prior to commencement of any work.
·Only those windows visible and unobscured from within thesubject property on the date of survey have been located.
·Tree information and canopy location is approximate (and notnecessarily symmetrical) and if critical may require furtherassessment.
·The DWG format file for this plan is integral and containsadditional spatial information not able to be displayed in thePDF file.
·This drawing and the information it contains is copyright andremains the property of SurveyPlus Pty Ltd. It must not becopied, used or altered without the express authority ofSurveyPlus.
·These notes and interests noted in the Certificate of Title forman integral part of this plan and must not be erased.
U
U
67.52
69.80
69.5067.12
70.19
66.54
70.17
70.24
69.85
67.24
70.6171.40
68.82
67.83
69.66
70.62
71.27
69.84
67.98
70.16
70.64
71.15
68.40
68.80
69.38
70.19
70.19
68.81
70.24
69.49
70.49
70.16
67.23
70.18
70.62
71.13
70.28
68.41
70.62
69.66
66.13
69.12
70.61
70.63
70.62
69.77
71.23
70.37
70.19
70.70
70.36
73.38
73.52 73.88
72.91
73.5773.65
72.72
74.68
73.56
74.27
72.56
72.90
73.59
73.34
73.61
74.67
73.88
73.15
72.56
72.93
70.44
71.3270.10
70.1771.37
71.45
70.17
70.16
71.49
71.4870.16
70.2571.55
71.67
70.22
69.04
70.3369.74
69.76
70.1770.19
69.81
69.7970.21
69.76
70.18
70.29
70.17
70.17
70.27
70.18
70.14
70.29 69.7069.81
69.89
70.28
71.76
71.70
71.69
71.87
71.85
71.95
71.55
71.37 71.96
71.1971.95
71.20
72.02
71.70
71.6871.6972.0272.01
71.74 72.05
72.19
72.08
71.78
71.8372.07
72.20
71.98
71.72
71.74
72.17
72.02
72.18
72.20
71.55
72.00
72.0071.61
72.20
71.72
72.20
72.20
71.74
71.78
72.22
72.21
71.8271.8472.22
72.22
71.89
72.01 72.24
73.26
73.24
73.26
73.13 73.2873.02 72.56
72.77
72.86
73.14
72.85
72.63
72.9272.9172.94
72.95
72.9272.93
72.9472.94 72.9373.04
73.10 73.08
73.0072.66
72.78
73.00
72.96
72.60
72.5872.94
72.93
72.55
72.54
72.5472.57
72.50
72.81
72.85
72.8972.81
72.76
72.78
72.56
72.83
72.58
72.32
72.93
72.5972.87 72.79
72.55
72.94
72.93
72.42
71.9172.33
72.29
72.41
71.29
71.26
72.09
70.7670.95
70.94 71.26
71.1270.10
71.14
70.09
70.84
70.17
70.6970.76
69.41
68.00
68.8667.99
68.01
69.33 69.13
70.1171.31
69.49
69.33
69.30
69.12
69.0470.15
70.35
70.35
70.55
70.56
70.76
70.69
70.40
71.06
70.59
70.33
70.53
70.74
70.74
70.93
70.93
71.1371.15
70.08
70.08
70.04
70.45
72.00
71.42
70.25
67.90
69.06
67.83
67.54
67.90
70.16
71.19
69.03
67.40
73.34
73.56
70.14
73.59
71.10
69.02
67.94
67.5070.14
70.15
73.35
72.61
71.63
73.24
73.36
73.26
72.97
72.31
72.78
72.03
72.33
73.65
73.42
73.47
73.16
72.50
72.64
73.50
73.42
73.46
73.57
72.99
72.30
72.42
72.53
72.82
73.04
73.0573.44
73.45
68.78
68.72
68.6468.6768.72
68.88
69.72
69.7569.62
69.6069.63 69.64
69.86
70.46
69.69
69.3369.67
71.98
72.73
68.4868.77
69.2669.56
69.53
69.22
68.76
68.59
68.49
69.2569.67
69.55
69.18
72.50
72.5372.55
72.60
70.08
70.0369.35
69.06
70.02
70.10
72.48
71.27
73.83
73.11
73.88
72.47
73.13
73.65
73.12
72.46
73.14
72.5273.88
73.66
73.71
73.33
70.59
70.80
71.16 71.31
71.71
69.73
71.09
72.60
73.28
72.5073.1472.50
70.12
69.92
69.01
73.13
68.40
73.39
67.72
70.55
68.27
68.75
68.62
68.90
70.85
68.57
68.53
68.74
69.9769.58
68.06
74.18
67.67
68.44
67.64
70.46
68.42
68.70
70.37
73.15
73.44
73.92
72.82
72.92
72.53
73.34
71.39
72.85
73.53
73.13
72.87
73.63
72.15
71.91
73.25
73.31
73.11
71.76
73.50
73.56
70.15
70.9370.76
71.60
76.03
73.74
71.97
72.06
72.10
72.05
72.96
72.88
70.8369.65
69.56
69.36
69.32 69.33
69.08 68.46
73.27
73.32
73.32
71.78
72.76
71.93
72.51
71.21
71.92
71.31
72.42
72.41
72.34
70.59
67.97
69.77
69.8569.76
69.83
69.93
69.8669.92
71.30
71.17
71.15
70.83
70.0470.08
70.10
72.82
73.21
72.83
72.63
68.4568.20
68.46
68.59
68.5968.47
68.4668.60
73.68
73.69
73.71
73.6173.64
73.69
73.72
73.79
73.62
73.6473.63
73.82
73.68
72.89
72.83
72.87
72.91
72.75
73.08
73.04
73.18
73.2673.1473.24
73.29
73.14
73.24
73.37
73.51
73.03
72.91
72.96
73.11
73.10
72.9772.9972.84
70.19
72.89
71.83
71.57
71.51
71.37
72.10
72.11
72.16
72.13
72.06
72.31
72.35
67.91
69.86
70.41
67.70
69.91
70.0169.77
70.80
70.75
72.95
71.08
71.66
73.70
72.97
72.92
73.60
73.59
73.60
75.85
68.74
71.39
66.45
72.42
72.38
72.23
73.37
73.42
73.41
73.67
72.48
73.47
73.73
71.65
72.16
72.17
71.97
71.59
72.39
70.04
67.90
72.40
72.39
72.40
72.0272.16
72.22
71.99
70.08
71.70
71.7068.93
69.72
71.56
71.10
69.7369.72
72.5972.57
71.97
72.4972.49
70.12
67.99
FL 72.92
FL 73.18
FL 72.91
FL 73.85FL
73.83
FL 76.18
FL 73.18
FL 73.17
FL 72.91
FL 73.18
FL 70.23
FL 70.17
FL 70.23
FL 68.06
FL 70.23
72.52
72.48
72.52
72.25
72.57
72.49
72.22
72.17
72.4872.48
72.4872.5272.53
72.77
72.72
72.63
70.22
70.10
70.0970.13
67.9867.96
67.90
73.23
73.34
73.48
73.67
73.66
73.67
73.03
73.65
73.67
73.68
73.67
73.15
R 78.10
R 77.36
R 78.10
R 76.96
R 77.75
R 77.45
R 77.89
R 75.92 R 75.88
R 79.35
R 78.49
R 79.63
R 78.22R 75.84
R 76.96
R 77.00
R 79.76
R 75.28
R 78.94
R 77.36
R 78.47R 76.52
R 79.17
R 79.74
R 77.01
R 82.25
R 75.56
R 79.18
R 77.80
R 77.30
R 76.95
R 79.65
R 79.64
R 79.61
R 79.63R 79.22R 79.73
R 79.73R 80.05
R 75.54
R 77.01
R 77.03
R 77.36
R 77.33
R 78.48R 78.48
R 79.74
R 75.60
R 75.62R 77.70
R 76.61
R 76.61
R 75.79R 75.77
R 75.74
R 74.51
R 77.00
R 76.24
R 76.21
R 78.89
R 78.95
R 73.42
R 76.61
R 76.58
R 75.45 R 75.44
R 76.36
R 76.62
R 76.99
R 77.00
R 77.89R 77.85
R 76.22
R 76.96
R 77.76
R 77.35
R 73.70
R 73.70
R 78.93R 78.93
G 76.75
G 74.36
G 76.76
G 76.60
G 74.36
G 76.74
G 79.95G 75.88
G 72.40
G 74.15
G 76.73
G 74.39
G 73.83
G 74.16
G 76.62
G 76.13
G 76.75
G 76.65
G 73.19
G 76.75
G 72.81
G 79.94
G 75.64
G 76.08
G 74.48
G 76.67
G 76.74
G 73.15
G 77.30
G 76.77
G 76.63
G 74.49
G 76.65
G 76.76
G 75.88
G 72.77
G 79.95
G 75.65
G 79.95G 76.61
G 76.64
G 77.83
G 76.65
G 77.88
G 76.76
G 76.32
G 76.28
G 75.16G 75.56
G 79.95
G 76.26
G 75.31
G 75.31
G 73.19
G 72.99
G 72.99
G 72.45
G 75.71G 75.72
G 79.28
G 76.45
G 79.30
G 79.28G 78.05
G 77.96
G 72.86
G 71.27
G 78.11
G 78.11
G 78.11
G 75.32
71.56
73.58
70.56
69.60
73.54
70.90
73.5670.16
68.76
67.98
71.16
71.25
69.88
70.85
71.08
73.61
73.38
71.27
69.62
70.18
69.95
73.42
71.82
73.25
71.56
73.55
73.19
73.71
73.64
72.40
72.73
73.15
72.4173.37
72.93
73.58
73.03
72.81
73.71
72.90
73.66
73.72
73.56
73.70
73.04
73.66
72.88
73.57
73.10
73.58
72.39
73.71
73.75
73.74
73.72
73.72
73.7373.72
75.84
75.87
72.02
72.15
73.11
72.95
72.18
71.59
75.75
75.77
75.04
72.5673.14
72.88
72.88
70.24
70.1570.16
70.12
71.73
73.37
73.36
73.72
73.72
79.9579.88
72.87
72.86
72.79
73.07
72.84
72.88
72.83
72.91
72.84
73.08
73.03
72.85
72.94
73.09
72.51
72.5172.54
70.21
73.03
68.54
68.60
69.99
68.76
73.79
69.67
73.65
68.0668.56
70.22
70.70
68.61
69.46
68.57
73.89
66.87
73.65
67.49
66.09
68.26
67.26
70.27
68.66
73.54
67.82
69.16
68.43
73.86
66.42
70.14
73.65
68.53
68.39
68.54
72.34
72.2572.19
73.62
73.21
73.10
71.04
72.31
72.33
73.08
72.37
72.95
73.29
71.74
73.70
71.70 71.70
71.89
71.86
72.06
72.01
70.46
69.31
71.94
71.96
72.61
68.91
67.90
67.73
68.16
69.86
73.4473.54
T-S7D0.7H25
T-S5D0.4H25
T-S6D0.6H20
T-S4D0.5H13
T-S4D0.4H13
T-S3D0.2H8
T-S3D0.4H13
T-S2D0.3H11
T-S3D0.3H9
T-S2D0.3H10
T-S2D0.3H12
T-S3D0.4H11
T-S2D0.2H9
T-S2D0.2H7
LINE MARKING
LIN
E M
ARKI
NG
VERANDAH
SINGLE STOREYRENDERED BUILDINGMETAL ROOF
VERANDAH
STEP
STEP
SINGLE & 2 STOREYRENDERED BUILDINGTILE ROOF
METALSHED
VERA
NDA
H CONCRETE
STEP
SEAT
SINGLE STOREYBRICK & METAL CLAD BUILDING
METAL ROOFSE
ATSE
AT
2 STOREYBRICK BUILDING
METAL ROOF
VER
COL COL COL
COLCOL
SEAT
CONCRETE
COL
COLCOL COL
COL COLCOL COL
COL
COL
SEAT
SEAT
SEAT
2 STOREYBRICK BUILDINGMETAL ROOF
FIBROSHED
3 STOREYBRICK BUILDING
METAL ROOF
W80
W79
D22
D23
COL
BRIC
K
WAL
L
COL
W81 W82 W83 W84
STEP
BRIC
K
W
ALL
COL
COL
BRIC
K
WAL
L
COL
BRICK WALL
COL COL
COL COL
COL
BRIC
K
W
ALL
COL
BRICK WALL
COL
BRICK WALL
BRIC
K
W
ALL
G 76.31
D24
W85D25
CONCRETE
COLCOLW136
W135
W134
D62
W133
D63
D26
STEE
L
D27D28D29D30D31
D32
D33
W86W87
D34
W88W89
D35D36
W90
D37
W91
D38
W92
D39
W99W98W97W96W95W94W93
SINGLE STOREYRENDERED BUILDINGMETAL ROOF
D43
D42
D41
D40
D44
D48 D47D49 D46
W107
D45
W106
W105
W104
W103
W102
W101
W100
W132
W131
W130
W129
W128
W127
D61
D60
D59
W125W124
W123
W122
W121D58
D57
W120
D56
D55
W119
W118
W117
D54D53
W116W115
W114W113
WAL
L
W110D52
D51
D50W109
W108
CONC W150
W148
D70
SEAT
UPIT
COL COL COL
SIP
SIPSIP
2 STOREYBRICK BUILDING
METAL ROOF
LI
LI
LI
LILI
LP
CONC
WALL
SIPBLOCK
SIP
D76W201
W209
W208
W207W206
D80 W205
CONCRETE PATH
CON
CRET
E PA
TH
CONC
WALL
WALL
BRIC
K
COL
BRICK WALL
D71
SIPSIP
SIP
SIP
SIP
SIPSIP
W77 W76SIP
W75D21W73 W71 W69
BRICK WALL
CONC
W198W197
W199
W196W195W194
W193W192W191
W189W188
W163
W165
W164W166
W168W167
W173W172W176W175W179W178W182W181
W162
D74
SIPU
BRICKWALL
W204
WALL
STEPS
D79W203 D78 D77
W202
CONC
HIGH WIRE MESH FENCE
PICKET FCE
STEEL
HYD H
UPIT
SIPCONC
WALL
BLOCK
COL COL
COL
COLCOL
COL
COL
CAGE
RAIL
RAIL COL
VER
RAIL
VERRA
IL
BOLCOL
D20
BRIC
K
WAL
L
W66W67W68
SIP
CON
C
COL
W145W144
WALL
BLOCK
SIP
EDGE
BITO
F
STW GRATESL 73.02IL 72.13
COL
STW GRATESL 72.54IL 72.05
WALL
BRIC
KW
ALL
SIP
TPIT T
TPITT
STEEL
FENCE
PICKETEDG
E
BITU
MEN
OF
CON
CRET
E
STW GRATESL 66.01IL 65.41
STW GRATESL 67.13IL 66.27
STW GRATESL 67.88IL 66.68
CON
C
STW GRATESL 69.00IL 68.75 STW GRATE
SL 69.07IL 68.78
STW GRATESL 69.27IL 68.98
CONCRETE
COL
COL
UPITU
CONC
CONC
HIG
HST
EEL
PICK
ET
FCE
UPR
IGH
T CO
NC
HIG
H
FEN
CE
STEE
LPI
CKET
CON
C
HIGH
FENCE
FEN
CEST
EEL
PICK
ET
WATERSTORAGE
TANK
CONC
W111
STEP
S
W112
HIGH
FENCE
STEEL
PICKET
CON
CRET
E
PAT
H
FEN
CEPI
CKET
LP
LP
LP
CON
C B
LOCK
WAL
L
D17
W55W54
W56
D18 W58W57
W59
WAL
L
D19
W61W60
W62
W64W63
W65
STW GRATESL 72.79IL 72.52
STW GRATESL 72.79IL 72.45
RAIL
EPIT
TPITT
EPITE
STW GRATESL 72.55IL 71.55
STW GRATESL 73.48IL 73.05
PAVING
CONC
STEP
SIP
SIP
WALL
WALL
CONCRETE
W126
STAIRS
SIPRAIL
STEP
STW GRATESL 70.07IL 69.93
STW GRATESL 72.48IL 70.98
COLRAMP
RAILRAIL
SIP
STW GRATESL 72.84IL 71.61
STEP
D64W137
STW GRATESL 70.08IL 69.14
COL
COL
STW GRATESL 72.35IL 71.24
COL
CON
CRET
E
COL
COL
WAL
L
COL
COL
W140
W139
D65W141
D66W142
W143
D67
D68
D69
STEP
CON
CRET
ERA
IL
W152
W154W153
W155
W156W157
WALL
WALL
STW GRATESL 71.50IL 71.31
STW GRATESL 71.36
METAL
FENCE
RAILSTEPS
LP
D72
W158
D73W159
W210
W161
W170
W169
W171
HYD H
LOG
RE
T
CONCRETE
W184
D75
W186
W187
COL
W147
W200
HYD H
WATW
LATT
ICE
FE
NCE
LAP
FENCE
AND
CAPPALIN
G
CON
C
W190
W174
W177
W180
W183 WALL
FENCE
W138
BRIC
KW
ALL
W185
UPIT
W160
SIP
RAIL
STEPS
CONC
RAIL
W149
W151
W146
HYDHCOL
COL
COL
WALL COL
EDG
EOF
CON
CRETE
UPRIGHT
FLAG
KERBCONCRETE
WALL
BLOCKWALL
WAL
L
W78 W74 W72 W70
FEN
CE
BLO
CKW
ALL
COL
67.98COL
RAIL
RAIL
STEP
S
BLOCK
WALLSTW GRATE
SL 70.08IL 69.18
2DP 579138
1.917ha(BY DP 579138)
COURT COURT
LINE MARKINGLINE MARKING
POST-GOALPOST-GOAL
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
1DP 1073750
25DP 211725
24DP 211725
23DP 211725
22DP 211725
21DP 211725
4DP 210926
3DP 210926
247° 52' 20"5.485
157°
52'
20"
9.75
5
5.48567° 52' 20"
64.965149° 49' 00"
324° 51' 50" ~ 80.38
326° 34' 50"43.485
34.85568° 42' 00"
157°
52'
20"
32.0
95
CONC BLOCKWALL
METALFENCE
CONC BLOCKWALL
COL
STEPS
COL
WALL
COL
WAL
L
COL
BRICK WALL
STEP
SEAT
CON
C
COL73
73
73
71
72
68
68
67
69
70
71
7272
69
70
KERB
FEN
CEPI
CKET
BRIC
KW
ALL
HIG
H
W
IRE
M
ESH
FCE
STATUE
2ND STOREYABOVE ONLY
BLOCK
CON
CMETAL
CARPORT
CONC
CONC
MET
ALAW
NIN
G
CONC BLOCK
W62a
N N
MGA
(BY D
P 10
5791
2)M
AGNETIC
(BY D
P 579
138)
LEGEND
- Sewer Inspection Pit
ET - Overhead Comms/Electricity Wires
COL - ColumnEPIT - Electrical Pit
HYD - Hydrant
LI - LightLP - Light Pole
RWT - Top of Retaining WallSI - SignSIP
SMH - Sewer Manhole
- Telecommunication PitTPIT- Unknown PitUPIT
- Water MeterWM- Water PointWAT
PP - Power Pole
STW - Stormwater
G XX.XX - Gutter RL XX.XX
R XX.XX - Ridge/Roof RL XX.XX
IL XX.XX - Invert Level RL XX.XX
- Surface Level RL XX.XXSL XX.XX
BOL - Bollard
FL - Floor LevelE
H
S
T
U
W
CLIENT REVISION DETAILSREVISION / DATE DATE OF SURVEY SURVEY BY DRAWN BY APPROVED BY
ORIGIN OF LEVELS
CONTOUR INTERVAL
ORIGIN OF COORDS
DRAWING TITLE SCALE
REVISION
SHEET
REF
01.05.2018
SSM 137580 RL 64.79 (AHD)
SSM 137580
0.5m
PLAN SHOWING DETAIL AND LEVELS OVERLOT 2 DP 579138 & LOT 5 DP 1057912
No. 24 EVANS ROAD, ROOTY HILL
1:200 @ A1
10505_DET_1A
A
A 14.05.2018 AS SURVEYED ON SITE PK RS PK
40m 2 1510 201 3 5
SCALE 1:200 @A1
3 OF 4Catholic Education Office -Diocese of Parramatta
T-S8D0.5H14
TREE DIAGRAM
Approx.Tree Height
Trunkdiameter
Approx. TreeRadius Spread
INTERESTS RELATING TO THE SUBJECT SITE:The Certificate of Title for Lot 2 DP579138 ordered on 29.03.2018& Lot 5 DP 1057912 ordered on 4.05.2018 identified thefollowing interests (refer to the original 88B Instrument orDealing creating the interest for specific terms - we recommendthis be undertaken prior to design or construction):Lot 2 DP579138·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·G773192 Covenant affecting part ~ (Not investigated).·P633156 Covenant ~ (Not investigated).·DP1137984 Easement for Padmount Substation 2.75 metre(s)
wide affecting the part(s) shown so burdened in DP1137984(Denoted (A) in this plan).
DP1137984 Restriction(s) on the use of land affecting the part(s)shown so burdened in DP1137984 (Denoted (B) in this plan).·AH309127 Positive Covenant ~ (Not investigated).·AH309128 Restriction(s) on the use of land ~ (Not investigated).
Lot 5 DP1057912·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·DP265736 Easement for drainage 1 wide appurtenant to the
land above described (remote to site - not shown).·DP1057912 Easement for drainage of water 1.5 metre(s) wide
appurtenant to the land above described (Denoted (C) in thisplan).
·DP1057912 Restriction(s) on the use of land referred to andnumbered 8 in S.88B instrument ~ (Not investigated).
NOTES·Do not scale from this plan.·The purpose of this Detail Survey plan is to show detail and
levels for planning and design. Do not use the informationshown for any other purpose.
·Plan coordinates have been determined from ground (real)distances and are related to an MGA (grid) point of origin. Ascale factor must be applied to convert plan coordinates to trueMGA grid coordinates.
·Contours are an indication of the topography and should only beused for planning purposes. Spot levels only should be used fordetailed design.
·A preliminary fixation of subject site boundaries has been made.Boundary dimensions and areas have been compiled from thecurrent subject site Deposited Plan. If any work is to beundertaken on or adjacent to a boundary then a BoundarySurvey is recommended to define the boundaries of the site.
·The relationship of built form and natural features to boundariesis diagrammatic and if critical should be confirmed by aBoundary Survey. Boundary setbacks (if shown) are approximateonly.
·Building and feature descriptions are to be used for generalidentification purposes only and may require furtherinvestigation.
·No services search has been undertaken. Only those servicesvisible at the time of survey have been located. It isrecommended to contact Dial Before You Dig and the relevantservice authority prior to commencement of any work.
·Only those windows visible and unobscured from within thesubject property on the date of survey have been located.
·Tree information and canopy location is approximate (and notnecessarily symmetrical) and if critical may require furtherassessment.
·The DWG format file for this plan is integral and containsadditional spatial information not able to be displayed in thePDF file.
·This drawing and the information it contains is copyright andremains the property of SurveyPlus Pty Ltd. It must not becopied, used or altered without the express authority ofSurveyPlus.
·These notes and interests noted in the Certificate of Title forman integral part of this plan and must not be erased.
68.48
64.25
64.28
63.3863.3963.46
63.37
63.36
62.9562.90
62.95
62.92
62.96
63.0763.2060.11
59.28
69.0269.33
68.57
68.50
68.5764.19
64.62
64.60
64.76
64.79
64.8464.81
64.8464.81
64.9164.97
64.98
64.97
68.33
68.48
68.49
68.3368.0968.28
68.62
68.68
68.96
69.25
69.18
68.88
68.65
68.41
68.08
68.05
68.4766.34
66.32 66.3466.3466.34
68.40
68.27
68.53
68.44
68.42
64.79
68.20
64.70
64.56
64.26
64.74
68.20
68.5568.94
68.9969.32 69.33
69.08 68.46
65.07
65.03
65.17
65.73
64.29
64.09
64.50
64.95
64.99
65.02
64.92
64.48
63.9863.8163.61
62.25
62.51
62.80
62.77
63.48 64.41
64.15 63.57
62.38
61.31
62.14
61.99
61.66
61.59
61.25
61.2761.4060.55
60.33
60.45
60.63
60.62
60.67
60.37
60.01
59.00
59.20
59.32
59.44
59.46
59.4359.28
59.15
62.77
62.11
61.69
61.48
61.16
61.64
62.18
64.42
64.40
64.52
64.89
64.33
64.26
64.23
64.50
67.80
67.64
67.48
67.23
65.16
65.41
65.26
64.88
64.29
68.20
67.89
68.1268.4668.47
68.12
68.19
68.46
64.0764.0364.18
64.37
64.23
64.2764.37
64.32
64.47
64.54
64.5564.39
64.40
64.4364.44
64.6264.57
64.73
64.79
64.7164.68
64.76
64.67 64.71
64.56
64.5264.66
64.51
64.37
64.43
64.3964.3464.48
64.34
64.2064.26
64.0964.04
64.19
62.17
61.57
61.4760.53
61.11
60.99
60.89
60.46
60.32
60.61
61.15
61.35
59.40
64.24
R 66.60
R 62.32
R 64.39
R 66.21
R 62.12
R 67.52
R 62.36
R 65.74
R 61.02
R 62.11
R 67.55
R 62.38
R 64.36
R 62.41
R 61.65
G 61.41
G 64.46
G 64.51
G 61.63
G 64.55
G 61.42
G 64.46
G 64.49
68.01
68.20
67.95
67.20
68.06
65.26
64.93
64.54
63.99
68.11
67.77
65.01
68.26
65.63
64.89
68.43
67.6768.09
67.67
65.01
65.12
64.66
69.3169.13
68.5168.23
65.08
63.58
63.25
63.17
62.26
61.51
60.87
59.07
59.20
59.31
59.34
59.35
59.32
59.18
59.04
59.04
60.53
61.63
63.9662.27
T-S4D0.4H25
T-S4D0.5H25
T-S2D0.4H20
T-S6D0.7H25
T-S5D0.6H25
T-S3D0.3H13
T-S6D0.5H25T-S7D0.6H25
T-S5D0.4H20
T-S6D0.5H25
T-S4D0.4H20
T-S3D0.3H10
T-S2D0.3H10
T-S3D0.3H9
T-S2D0.3H10
CON
CRET
E
PAT
HCO
NCR
ETE
PATH
CONCRETE PATH
HIGH WIRE MESH FENCE
HIG
H
WIR
E
MES
H
FC
E
T-S5D0.4H20
SINGLE STOREYBRICK BUILDING
TILE ROOF
FIBROSHED
SINGLE STOREYWEATHERBOARD BUILDING
METAL ROOF
SINGLE STOREYWEATHERBOARD BUILDING
METAL ROOF
SMHS
CON
C BLOCK W
ALL
CONCBLOCK WALL
BOTTOM BAN
K
OFTO
P
OFBANK
BANK
TOP
OF
BOTTOM
BANK
OF
CON
CRET
E
PAT
H
HIG
HFE
NCE
METAL
FENCE
PANEL
METAL
FENCEPANEL
METAL
PANEL
FENCE
HIG
H
STEEL
PICKET
FENCE
CONC
KERB
UPRIGHT
CONCRETE
UPRI
GHT
KERBCONCRETE
CONC
RETE
PATHHIGHFENCESTEEL PICKET
HIG
HFE
NCE
STEE
LPI
CKET
STEPS
W211
W212
W213
W214 W216 W217W215
2DP 579138
1.917ha(BY DP 579138)
5DP 1057912
4364m²(BY DP 1057912)
LINE MARKINGPOST-GOAL
COURT COURT
LINE MARKINGPOST-GOAL
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
LIN
E
MAR
KIN
G
6DP 1057912
3DP 210926
2DP 210926
ST AGNES AVENUE
19DP 210926
149° 49' 00"
82.658° 52' 30"
79.98559° 14' 35"
326° 34' 50"43.485
238° 51' 45"49.765
16.5149° 48' 20"
233° 03' 05"4.5
45.33149° 21' 30"
328° 51' 50"42.69
222° 19' 55"
CH 6.82
ARC 6.915
RAD 12
328° 51' 45"12
267° 20' 30"CH 21.095
ARC 25.77RAD 12
49DP 14839
48DP 14839
47DP 14839
46DP 14839
45DP 14839
44DP 14839
69
68
67
66
65
64
63
62
61
60
RAIL
RAIL
BENCHMARKSSM 137580 IN KERBRL 64.79m (AHD)
(C)
1DP 1073750
TOPBANKOF
STEPS
N N
MGA
(BY D
P 10
5791
2)M
AGNETIC
(BY D
P 579
138)
LEGEND
- Sewer Inspection Pit
ET - Overhead Comms/Electricity Wires
COL - ColumnEPIT - Electrical Pit
HYD - Hydrant
LI - LightLP - Light Pole
RWT - Top of Retaining WallSI - SignSIP
SMH - Sewer Manhole
- Telecommunication PitTPIT- Unknown PitUPIT
- Water MeterWM- Water PointWAT
PP - Power Pole
STW - Stormwater
G XX.XX - Gutter RL XX.XX
R XX.XX - Ridge/Roof RL XX.XX
IL XX.XX - Invert Level RL XX.XX
- Surface Level RL XX.XXSL XX.XX
BOL - Bollard
FL - Floor LevelE
H
S
T
U
W
CLIENT REVISION DETAILSREVISION / DATE DATE OF SURVEY SURVEY BY DRAWN BY APPROVED BY
ORIGIN OF LEVELS
CONTOUR INTERVAL
ORIGIN OF COORDS
DRAWING TITLE SCALE
REVISION
SHEET
REF
01.05.2018
SSM 137580 RL 64.79 (AHD)
SSM 137580
0.5m
PLAN SHOWING DETAIL AND LEVELS OVERLOT 2 DP 579138 & LOT 5 DP 1057912
No. 24 EVANS ROAD, ROOTY HILL
1:200 @ A1
10505_DET_1A
A
A 14.05.2018 AS SURVEYED ON SITE PK RS PK
40m 2 1510 201 3 5
SCALE 1:200 @A1
4 OF 4Catholic Education Office -Diocese of Parramatta
T-S8D0.5H14
TREE DIAGRAM
Approx.Tree Height
Trunkdiameter
Approx. TreeRadius Spread
INTERESTS RELATING TO THE SUBJECT SITE:The Certificate of Title for Lot 2 DP579138 ordered on 29.03.2018& Lot 5 DP 1057912 ordered on 4.05.2018 identified thefollowing interests (refer to the original 88B Instrument orDealing creating the interest for specific terms - we recommendthis be undertaken prior to design or construction):Lot 2 DP579138·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·G773192 Covenant affecting part ~ (Not investigated).·P633156 Covenant ~ (Not investigated).·DP1137984 Easement for Padmount Substation 2.75 metre(s)
wide affecting the part(s) shown so burdened in DP1137984(Denoted (A) in this plan).
DP1137984 Restriction(s) on the use of land affecting the part(s)shown so burdened in DP1137984 (Denoted (B) in this plan).·AH309127 Positive Covenant ~ (Not investigated).·AH309128 Restriction(s) on the use of land ~ (Not investigated).
Lot 5 DP1057912·Reservations and Conditions in the Crown Grant(s)
(Not investigated).·DP265736 Easement for drainage 1 wide appurtenant to the
land above described (remote to site - not shown).·DP1057912 Easement for drainage of water 1.5 metre(s) wide
appurtenant to the land above described (Denoted (C) in thisplan).
·DP1057912 Restriction(s) on the use of land referred to andnumbered 8 in S.88B instrument ~ (Not investigated).
NOTES·Do not scale from this plan.·The purpose of this Detail Survey plan is to show detail and
levels for planning and design. Do not use the informationshown for any other purpose.
·Plan coordinates have been determined from ground (real)distances and are related to an MGA (grid) point of origin. Ascale factor must be applied to convert plan coordinates to trueMGA grid coordinates.
·Contours are an indication of the topography and should only beused for planning purposes. Spot levels only should be used fordetailed design.
·A preliminary fixation of subject site boundaries has been made.Boundary dimensions and areas have been compiled from thecurrent subject site Deposited Plan. If any work is to beundertaken on or adjacent to a boundary then a BoundarySurvey is recommended to define the boundaries of the site.
·The relationship of built form and natural features to boundariesis diagrammatic and if critical should be confirmed by aBoundary Survey. Boundary setbacks (if shown) are approximateonly.
·Building and feature descriptions are to be used for generalidentification purposes only and may require furtherinvestigation.
·No services search has been undertaken. Only those servicesvisible at the time of survey have been located. It isrecommended to contact Dial Before You Dig and the relevantservice authority prior to commencement of any work.
·Only those windows visible and unobscured from within thesubject property on the date of survey have been located.
·Tree information and canopy location is approximate (and notnecessarily symmetrical) and if critical may require furtherassessment.
·The DWG format file for this plan is integral and containsadditional spatial information not able to be displayed in thePDF file.
·This drawing and the information it contains is copyright andremains the property of SurveyPlus Pty Ltd. It must not becopied, used or altered without the express authority ofSurveyPlus.
·These notes and interests noted in the Certificate of Title forman integral part of this plan and must not be erased.