Top Banner
Operation Manual Fiber Optic Illuminator Model 21AC Model 21DC
12

l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

Aug 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

Op

erat

ion

Man

ual

Fiber OpticIlluminator

Model 21ACModel 21DC

Page 2: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

Warning

This symbol is intended to alert

the user to the presence of uninsulat-

ed “dangerous voltage” within the

product’s enclosure that may be of

sufficient magnitude to constitute a

risk of electric shock to persons.

This symbol is intended to alert

the user to the presence of important

operating and maintenance (servicing)

instructions to the literature accom-

panying the appliance.

Important

This equipment has been tested and

found to comply with IEC 61010-1

and UL3101-1 as an Overvoltage

Category II: (local level, small

appliances, portable equipment, etc.

with smaller transient overvoltages

than Overvoltage Category III.)

Pollution II.

Caution

You are cautioned that any change

or modifications not expressly

approved in this manual could

void your authority to operate

this equipment.

Precautions

On Power Sources

• Before operating the product,

check that the operating voltage

is identical to your local power

supply. See specific descriptions

for operating voltages.

• This unit is not disconnected from

the AC power source as long as it

is connected to the wall outlet,

even if the unit itself has been

turned off.

• To disconnect the AC power cord,

grasp the plug itself; never pull

the cord.

• One blade of the plug is wider

than the other for the purpose

of safety and will fit into the wall

outlet only one way. If you are

unable to fully insert the plug into

the outlet, contact Techniquip.

• AC power cord must be replaced

with IEC compatible cord.

On Operation

• Before connecting to fiber optic

components, be sure that all

power connections are secure.

On Cleaning

• Clean the cabinet, panel and

controls with a soft cloth slightly

moistened with a mild detergent

solution. Do not use any type of

abrasive pad, scouring powder or

solvent such as alcohol or benzine.

Page 3: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

Fiber OpticIlluminator

Model 21AC

If you have any questions or problems concerning your product,

please consult Techniquip.

For Customers in Canada

CAUTION

TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS POLARIZED AC PLUG

WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS

THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

Owners Record

The model and serial number are located on the bottom of the unit. Record the

serial number in the space provided below. Refer to them whenever you call

upon your Techniquip dealer regarding this product.

Model Number

__________________________

Serial Number

__________________________

Page 4: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

iii

Contents

MODEL 21ACGetting Started 1

Unpacking 1

Hookup Overview 1

Description 1

Illuminator Descriptions (Front Panel) 1

Illuminator Descriptions (Rear Panel) 2

Lamp Replacement 3

Specifications 4

Model Codes 5

Page 5: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

21

Illuminator Descriptions (Rear Panel)

1. T-slot mounting for #1/4 - 20 or M6 hexhead fastener;both sides (#10 - 32 or M5 barnut optional)

2. IEC inlet with line filtering (power cable input)3. Operating voltage label:

Illuminator Descriptions (Rear Panel)

DescriptionGetting Started

Unpacking - MODEL 21AC

Check that you received all items on the packing list.

Hookup Overview

The Model 21AC Illuminator allows you to connect and control avariety of fiber optic components. To learn the locations and namesof important connections see “Illuminator Descriptions” beginningon this page below.

Before You Get Started

• Turn off the power to the Model 21AC Illuminator beforemaking any connections.

• Do not connect the AC power cord to the local powersupply until the connections are completed to the Model21AC Illuminator.

• Be sure to make connections firmly.• Be sure that the Model 21AC operating voltage matches

the “local” power supply.

Illuminator Descriptions (Front Panel)

1. Variable intensity controller (0 to 100%).2. On/Off rocker switch.3. Front panel fasteners (2X)4. Lamp module.5. V-port with T-handle retainer

Page 6: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

43

Lamp Replacement Instructions

1. To replace the lamp, shut off the power and remove thepower cord from the AC outlet. To disconnect the ACpower cord, grasp the plug itself; never pull the cord.

2. Located on the lamp access panel, manually loosen thefront panel fasteners.

3. With front panel released, remove the lamp module fromthe unit.Use caution; fan blades are accessible while lampmodule is removed.

4. Allow sufficient time for the unit to cool. CAUTION:Lamp and surfaces may be extremely hot!

5. Remove the lamp from the socket and place in a safe area.

6. Insert the replacement lamp into the socket; pressingfirmly to ensure that pins are fully seated.

7. Close the access panel.

8. Secure the lamp access panel by manually tightening the front panel fasteners.

On Safety

Should any solid object or liquid fall into the assembly while accesspanel is open, have it checked by qualified personnel before operating.

Lamp Replacement Specifications

Specifications

EnvironmentalIntended for indoor use onlyOperating temperature: -4 to 104°F (-20° to 40°C)Humidity range: 0 to 80%; non-condensingPollution degree: 2

Electrical (all units)Operating frequency: 60 Hz (110 VAC) or 50 Hz (220VAC)Power consumption: 180 watts at full light intensityPower requirements: 110 VAC; 60 Hz

220 VAC; 50 HzLamp adjustment range: 0 to 100%Color temperature: 3200K at maximum intensity

(assuming standard EKE lamp)Lamp life: 250 to 10,000 hours

PhysicalMass (approx.): 4.5lbs. (2.04kgs)

Replacement Parts

Lamp ReplacementLamp Type: 150W EKE, 3250K (#20094145)*

150W EKE-HC, 4200K (#20094142)150W EJV, 3400K (20094143)

* Standard lamp type provided with illuminator.

Fuse ReplacementFuse Type: 3.15A 250V, 5x20mm (#02610014)

Page 7: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

5

ModificationsMaterial TypeLamp TypeLamp Module (nosepiece)Cord SetInput VoltageModel

Model Codes

Model 21AC Matrix

21AC 1 K 1 00 X -XXX

Model: 21AC Model 21AC

Input Voltage: 1 110 VAC; 60 Hz2 220 VAC; 50 Hz

Cord Set: A Euro/Shuko H IsraelC Australia I ItalyD United Kingdom K North AmericaE Denmark L SwitzerlandF France/Belgium R RussiaG India X No Plug

Lamp Module: 1 Ø1.0” (25.4mm) thru2 Ø0.625” (15.88mm) V-port

Lamp Type: 00 EKE, 3250K (standard)01 EKE-HC, 4200K (high color temperature)02 EJV, 3200K (high output)

Material Type: X Standard material finish

Modifications: To Be Determined (consult factory)

Fiber OpticIlluminator

Model 21DC

Page 8: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

87

Unpacking - MODEL 21DC

Check that you received all items on the packing list.

Hookup Overview

The Model 21DC Illuminator allows you to connect and control avariety of fiber optic components. To learn the locations and namesof important connections see “Illuminator Descriptions” beginningon this page below.

Before You Get Started

• Turn off the power to the Model 21DC Illuminator beforemaking any connections.

• Do not connect the AC power cord to the local powersupply until the connections are completed to the Model21DC Illuminator.

• Be sure to make connections firmly.• Be sure that the Model 21DC operating voltage matches

the “local” power supply.

Illuminator Descriptions (Front Panel)

1. Variable intensity control knob (0 to 100%).2. Power and lamp life indicators3. Front panel fasteners (2X)4. Lamp module.5. V-port with T-handle retainer

Getting Started /Description

MODEL 21DCGetting Started 8

Unpacking 8

Hookup Overview 8

Description 8

Illuminator Descriptions (Front Panel) 8

Illuminator Descriptions (Rear Panel) 9

Lamp Replacement 10

Specifications 12

Model Codes 13

Contents

Page 9: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

109

Illuminator Descriptions (Rear Panel)

1. T-slot mounting for #1/4 - 20 or M6 hexhead fastener;both sides (#10 - 32 or M5 barnut optional)

2. IEC inlet with line filtering (power cable input)3. Operating voltage label:

4. DB-9 connector for remote operation

Description

1 = Internal 1mA, 5VDC output

2 = Secondary common (same as 7)3 = Lamp intensity control4 = Ties to common to engage

supply programming5 = No connection

6 = External shut off/interlock(external 5VDC/10mA will shut off lamp)

7 = Secondary common (same as 2)8 = Chassis ground9 = Lamp error signal

Lamp Replacement

Intensity Control

• Pin 4 activates remote operation when tied to common(pin 2 or 7). Note: Front panel control is disengaged during remote operation.

• Intensity level is controlled by Pin 3 by supplying a 0-5DC signal

• The internal voltage from Pin 1 may be used in conjunction with a remote potentiometer to vary intensitythrough Pin 3.

Remote On/Off

• Unit power, including the lamp, is controlled by Pin 6.• An external isolated signal (5VDC, 10mA) will shut off

power to the lamp. Power is restored to the lamp byremoving the 5VDC signal from Pin 6 (open).

Lamp Error Signal

• Pin 9 is the lamp error signal output. If Pin 9 is at 5V, thelamp is okay. If Pin 9 is at 0V, the halogen lamp will burnout in the near future, or it is burnt out, or there is nolamp in the lamp module. Pin 9 is at 5V when the LampLife indicator is unlit. Pin 9 is 0V when the Lamp Life LEDindicator is lit.

Illuminator Installation and Mechanical Dimensions

Page 10: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

1211

Lamp Replacement Instructions

1. To replace the lamp, shut off the power and remove thepower cord from the AC outlet. To disconnect the ACpower cord, grasp the plug itself; never pull the cord.

2. Located on the lamp access panel, manually loosen thefront panel fasteners.

3. With front panel released, remove the lamp module fromthe unit.Use caution; fan blades are accessible while lampmodule is removed.

4. Allow sufficient time for the unit to cool. CAUTION:Lamp and surfaces may be extremely hot!

5. Remove the lamp from the socket and place in a safe area.

6. Insert the replacement lamp into the socket; pressingfirmly to ensure that pins are fully seated.

7. Close the access panel.

8. Secure the lamp access panel by manually tightening the front panel fasteners.

On Safety

Should any solid object or liquid fall into the assembly while accesspanel is open, have it checked by qualified personnel before operating.

Lamp Replacement Specifications

Specifications

EnvironmentalIntended for indoor use onlyOperating temperature: -4 to 104°F (-20° to 40°C)Humidity range: 0 to 80%; non-condensingPollution degree: 2

ElectricalPower consumption: 180W (Power factor corrected for CE)Power requirements: 90-254 VAC; 47-63 HzLamp adjustment range: 0 to 100%Color temperature: 3200K at maximum intensity

(assuming standard EKE lamp)Lamp life: 250 to 10,000 hoursAgency approvals UL 1950, CSA, CE, TUV & FCC

(Pending)

PhysicalMass (approx.): 4.5lbs. (2.04kgs)

Replacement Parts

Lamp ReplacementLamp Type: 150W EKE, 3250K (#20094145)*

150W EKE-HC, 4200K (#20094142)150W EJV, 3400K (20094143)

* Standard lamp type provided with illuminator.

Fuse ReplacementFuse Type: 3.15A 250V, 5x20mm (#02610014)

Page 11: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

13

ModificationsMaterial TypeLamp TypeIris ModuleLamp Module (nosepiece)Cord SetInput VoltageModel

Model 21DC Matrix

Model: 21DCModel 21DCNote: All options are universal input (90-254VAC; 47-63Hz) and include 0-5V analog control capabilities.

Options: U Standard DC regulated operationP DCU w/PC interface (RS232)S DCU w/optical loop feedback, no PC interfaceL DCU w/optical loop feedback and PC interface

Cord Set: A Euro/Shuko K North AmericaC Australia L SwitzerlandD United Kingdom Z North AmericaH Israel X No Plug

Lamp Module: 1 Ø1.0” (25.4mm) thru2 Ø0.625” (15.88mm) V-port3 Ø1.0” (25.4mm) V-port for use with/IR & color filter4 Ø1.0” (25.4mm) V-port w/2 Hz shutter

Lamp Type: 0 EKE, 3250K (standard)1 EKE-HC, 4200K (high color temperature)2 EJV, 3200K (high output)

Material Type: X Standard material finish

Modifications: To Be Determined (consult factory)

21DC L K 1 0 0 -X ––––

Model Codes

E:MAIL

Chuck Mathewson [email protected] Grauer [email protected] Wensley [email protected]

PHONE

Toll Free 888-414-0789International 1-925-251-9030

Fax

925-251-0704

MAILING

Street: 5653 Stoneridge Dr., Suite 101, Pleasanton CA 94588Mailing: PO Box 3310, Danville, CA 94526

Warranty

TechniQuip warrants this product to be free from defect in materialand workmanship for a period of 12 months following original purchase. This warranty excludes any product which may havebeen misused, neglected, damaged, or altered – including non-factory authorized repairs. TechniQuip’s obligations under this warranty are limited to the repair, replacement, or reimbursement of the product only, and in no event is TechniQuip liable for any consequential or special damages, or any cost related to transportation, installation, or any other cost related to a warranted product.

Page 12: l a u Fiber Optic n Illuminator a M n Model 21AC o …...Lamp module. 5. V-port with T-handle retainer 3 4 Lamp Replacement Instructions 1. To replace the lamp, shut off the power

5653 Stoneridge Drive #101Pleasanton, CA 94566

Phone: 925-251-9030 Fax: 925-251-07041-888-414-0789 (toll-free)

Version A04.15.06