Top Banner
AVT 1 User manual 0901489
16

Kompaktna stanica Polytron

Mar 09, 2016

Download

Documents

Kerman d.o.o.

Upute za kompaktnu stanicu Polytron
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Kompaktna stanica Polytron

AVT 1

User manual

0901489

Page 2: Kompaktna stanica Polytron

INDEX

1. GENERAL DESCRIPTION.

2. SAFETY INSTRUCTIONS.

3. OPERATING ADJUSTMENTS.

4. CONNECTIONS.

5. INSTALLATION.

6. INSTALLATION EXAMPLE.

7. TECHNICAL SPECIFICATIONS.

Page 3: Kompaktna stanica Polytron

1. GENERAL DESCRIPTION

Thank you for buying this digital terrestrial

modulator.

Please read this manual carefully to

install, use and maintain the modulator in

the best conditions of performance. Keep

this manual for future consults.

The product you have acquired is a state

of the art which main characteristics are:

• DVB-T modulator compatible with

standard ETSI EN 300 744 v1.5.1

• Fully compatible with standard DVB-

T/H.

• CVBS video input( via RCA ) or S-

VHS.

• Stereo.

• VHF-UHF band( 47~860 MHz )

• Generation of PSI tables: PAT, PMT;

SI: SDT, NIT.

• Generation of LCN ( Logic Channel

Numbering ).

• PAL and NTSC video formats.

• Picture aspect ratio: 4:3, 16:9 and AUTO

( depends of WSS on video source )

• 2K mode operation.

• Constellation of 16QAM and 64QAM.

• Different types of channels regions (

Australia, Western Europe… )

• Editable channel name and network

provider.

The supervision and control of AVT 1 is

done by LCD display. It is configured by an

intuitive navigation menu. Start to enjoy AVT

1.

Page 4: Kompaktna stanica Polytron

NOTE The contents of this company manual are copyrighted and must not be duplicated or copied in any form, either partially or in full, without the prior consent of the creator. Changes in this company manual which are carried out without consent of the creator can lead to the loss of the guarantee or to the rejection of the product liability on the part of the manufacturer. The creator is grateful for suggestions for improvement.

Creator: Polytron-Vertrieb GmbH

Postfach 10 02 33 75313 Bad Wildbad

Germany

The following emphases are used in this manual with the following meanings:

NOTE apply to technical requirements which the user of the equipment must particularly take into account to ensure a faultless function of the equipment/plant.

ATTENTION refers to instructions which have to be adhered exactly to avoid damage or destruction of the device.

CAUTION stand for instructions whose nonobservance doesn't exclude the endangering of persons.

At references to a component e.g. (figure 1/3) provided by a place number the reference to picture 1 place number 3 refers in this example.

2. Safety instructions Before taking the unit into operation please read the following safety precautions carefully! Important: The unit should only be opened by qualified persons. The unit must be disconnected from its power supply before service work is carried out. When the unit is open parts may be accessible through which dangerous voltages flow and with which contact may endanger your life. To guarantee the EMC protection of the amplifier the lid must be bold tight again after opening the amplifier.

Ambient temperature The ambient temperature should not exceed a range of 0 °C to +50 °C (32 °F to 122 °F). Humidity The unit may not be exposed to water drops or spray. If condensation is present, wait until the unit is dry before taking it into operation. Mains connection and mains cable By units with the power supply safety class I, the wire which is coloured green/yellow must be connected to the terminal in the plug marked with the letter "E" or by the earth symbol . The blue coloured wire must be connected to the terminal marked "N" and the brown coloured wire to the terminal marked "L". Units which operate with a remote feeding supply may not be connected to 230 VAC. To do so will endanger your life! At units with the power supply safety class II, the housing of the unit must be connected to ground at the place indicated in the operating instructions of the unit. The ground terminal of the plug is in the case not connected. Grounding of system According to EN 50 083 / VDE 0855 regulations, the antenna system must comply with the safety regulations e.g. grounding, potential equilization etc. Precautions to ensure the electro magnetic compability (EMV) All covers and screws must tightly be fitted and should be tightly fastened. Contact feathers should not be oxidated or deformed.

Page 5: Kompaktna stanica Polytron

Any tampering can be dangerous and can perform the warranty invalid.

The modulator is powered with a voltage of 7.5VDC. The power supply voltage

must not exceed that otherwise the modulator could suffer irreparable damage and

subsequent invalidation of the warranty. Therefore:

Do not replace power supply with a voltage greater tan 7.5VDC. � Do not connect the modulator to the power if the power cord is damaged. � Do not plug the modulator into mains supply until all cables have been connected

correctly. � Do not cut the cord. • Modulator shall not be exposed to dripping or splashing water and no objects

filled with liquids, such as vases, shall be placed on it.

• Avoid placing modulator next to central heating components and in areas of high

humidity.

• Do not cover modulator elements that obstruct the ventilation slots and avoid

overheating.

• If the modulator has been kept in cold conditions for a long time, keep it in a warm

room no less than 2 hours before plugging into the mains.

• Mount the modulator in vertical position with the connectors located on the bottom

side.

• From top, front and bottom of installed modulator must be at least 10cm free

space.

Connect modulator to ground connection with terminal provided

(see point 5-B).

Page 6: Kompaktna stanica Polytron

3. OPERATING ADJUSTMENTS

3.1 MODULATOR BOOT

When modulator is booting display shows firmware version during 2 seconds:

Next message shown is:“Booting…”

During that period of time the module is loading the firmware and initiating

internal devices.

Once started on the screen:

This message indicate modulator output channel, where XX is output channel (depends channel region selected ) and FFFFFF is frequency in kHz including

fine adjustment. Example:

*Output channel: C21 ( Western Europe ) with 25kHz of fine adjustment.

Note: switch menu language to English holding simultaneously down

buttons at power on. This operation can help you to restore bad

language configurations.

V20101214

Booting...

Running... XX (FFFFFF

Running... 21 (474025 )kHz

Page 7: Kompaktna stanica Polytron

BASIC MENU ATTENUATION

BASIC MENU LANGUAGE

OUTPUT

ATTENUATION 30 %

BASIC MENU EXIT

BASIC MENU OUTPUT

3.2 FAST CONFIGURATION Default configuration is: - Channel Region: WESTERN EUROPE - Output Channel: C28 - Guard interval: 1/16 - Channel name:CH A - Attenuation: 30% - PID Video: 33 - Network name: NET A - Constelation: QAM16 - PID Audio: 34 - Video input: CVBS - FEC:3/4 With buttons you can do a fast channel change, press for confirmation.

Press to enter menu. Select “BASIC MENU” and press to enter.

In this menu you can change basic parameters as: Output channel, attenuation and

language.

1) Adjust output channel depending on the selected

channel region.

With buttons select desired channel and press

to confirm.

2) Adjust output level of the modulator, select attenuation

value between 0 to 100% ( 15 dB typ. )

3) Select menu language.

AVT 1 has 11 installed languages. Remember that

switch menu language to English holding

simultaneously down buttons at power on.

4) Exit from basic menu with

OK

OK OK

OK

OK

Page 8: Kompaktna stanica Polytron

OUTPUT CHANNEL

ADVANCED MENU

CHANNEL REGION

ADVANCED MENU

FINE ADJUST 786100 kHz

ADVANCED MENU

ADVANCED MENU

ADVANCED MENU

ATTENUATION 30 %

CONSTELLATION QAM16

3.3 ADVANCED CONFIGURATION

Press to enter menu, select “ADVANCED MENU” and press to enter.

This menu allows you to adjust advanced parameters of modulator. 1) Select channel region to be used.

Note: depends of channel region selected,

modulated signal will have a center frequency and

bandwidth, select the correct region as location of

installation, otherwise you may have tuning problems.

2) Adjust output channel depending of selected

region. With buttons change output channel and

press to confirm.

3) Adjust center frequency of modulated

channel. Fine adjust allows to change center

frequency between ±100kHz.

Display shows output frequency including offset.

4) Adjust the output level of the modulator

according to your installation, select the attenuation

value between 0 and 100% (15 dB typ.)

5) Select constellation of modulated signal.

Select between QAM16 and QAM64.

OK OK

OK

Page 9: Kompaktna stanica Polytron

ADVANCED MENU

FEC 7/8

ADVANCED MENU GUARD INTERVAL

GUARD INTERVAL 1/16

ADVANCED MENU

SPECTRUM INV. OFF

ADVANCED MENU VIDEO PID

VIDEO PID 33

ADVANCED MENU PID AUDIO

PID AUDIO 34

ADVANCED MENU VIDEO BITRATE

VIDEO BITRATE 6144kbps

6) Adjust FEC (Forward error correction). FEC

adjust can be changed between:1/2, 2/3, 3/4,5/6,7/8.

7) Adjust Guard Interval between:

1/4, 1/8, 1/16 1/32.

8) Turn on or off spectral inversion. With this

function you can prevent incompatibilities in the

reception of modulated channel.

Note: this function is disabled by default.

9) Select video PID.

Adjust between 33 and 8190.

10) Select audio PID.

Adjust between 33 and 8190.

Note: video PID and audio PID must be different.

11) Adjust VIDEO BITRATE between 6144kbps

and 12288kbps with 512kbps steps.

Page 10: Kompaktna stanica Polytron

AUDIO BITRATE 192kbps

ADVANCED MENU CHANNEL NAME

CHANNEL NAME CH A

ADVANCED MENU

NETWORK NAME

ADVANCED MENU NETWORK ID

NETWORK ID 0xhhhh

12) Adjust AUDIO BITRATE between 128kbps

and 384kbps with 64kbps steps.

Note: the audio and video BITRATE adjustment

should be done within the margins allowed by the

selected modulation ( constellation, FEC, guard

interval).

13) Edit modulated channel name.

14) Edit network name.

Note: Select char to be changed with buttons, char appears blinking,

press to select char (it appears underlined) and with select new

char, confirm change with . To save new name press until end of line

(see that any char appears blinking) and press . New name will be stored in

memory.

15) Edit network identificator.

Network ID should be set according to the ETSI TS

101 162 Norm and following your country

regulation.

OK

OK

OK

Page 11: Kompaktna stanica Polytron

ADVANCED MENU LCN

LCN OFF

ADVANCED MENU VIDEO SOURCE

VIDEO SOURCE CVBS

ADVANCED MENU VIDEO STANDARD

VIDEO STANDARD PAL

ADVANCED MENU ASPECT RATIO

ASPECT RATIO AUTO

ADVANCED MENU BRIGHTNESS

ADVANCED MENU CONTRAST

16) Set LCN of modulated channel.

Logical Channel Number (LCN), also known as virtual

channel, is a channel designation which differs from

the actual radio channel or frequency on which the

signal travels.

17) Select video input.

Select between CVBS (Composite video baseband

signal, RCA connection) and S-VHS (video format in

which video information is encoded in two channels.

Brightness/luminance (Y) in one channel, and

color/chrominance (U and V) in other channel, S-Video

connection).

18) Select video standard to be used. Select

between PAL and NTSC.

19) Select aspect ratio. Select 4:3, 16:9 and

AUTO.

Note: AUTO depends of WSS (Wide Screen

Signaling) from video source.

20) Adjust image brightness.

21) Adjust image contrast.

Page 12: Kompaktna stanica Polytron

ADVANCED MENU SATURATION

ADVANCED MENU DEFAULT CONFIG.

ADVANCED MENU EXIT

ADVANCED MENU LANGUAGE

22) Adjust color saturation.

23) Select menu language.

AVT 1 has 11 installed languages. Remember that

switch menu language to English holding

simultaneously down buttons at power on.

24) Make a factory default with this option.

Note: this operation is undoable if you

make a factory default all data inserted by user will be

deleted. Modulator will restart after default

configuration function made.

25) Exit from advanced menu with

4. CONNECTIONS 1. Power supply: 7,5VDC/2A.

2. RS-232 Connector for PC.

3. RF Output.

4. S-VHS video input.

5. RCA video input.

6. RCA right audio input.

7. RCA left audio input.

8. Ground connection..

OK

Page 13: Kompaktna stanica Polytron

5. INSTALLATION

A. Screw modulator where you want

to install it.

Remember: From top, front and

bottom of installed modulator must

be at least 10cm free space.

B. Connect modulator ground to

installation ground, as shown in

picture.

WARNING: For the protection of your equipment and its proper working is necessary to connect the modulator to a ground connection.

C. Connect cables to audio/video source.

Page 14: Kompaktna stanica Polytron

D. Connect RF out to distribute modulated signal.

6. INSTALLATION EXAMPLE

According to the WEEE (Waste Electrical and Electronic Equipment) EU Directive, do not dispose of this product as household waste or commercial waste. Waste electrical and electronic equipment should be appropriately collected and recycled as required by practices established for your country. For information on recycling of this product, please contact your local authorities, your household waste disposal service or the shop where you purchased the product.

Page 15: Kompaktna stanica Polytron

7. TECHNICAL SPECIFICATIONS

.

Page 16: Kompaktna stanica Polytron

Polytron-Vertrieb GmbH

Postfach 10 02 33

75313 Bad Wildbad

H.Q. Order department

+ 49 (0) 70 81/1702 0

Technical hotline + 49 (0) 70 81/1702 - 12

Telefax + 49 (0) 70 81) 1702 - 50

Internet http://www.polytron.de

eMail [email protected]

Technische Änderungen vorbehalten

Subject to change without prior notice

Copyright © Polytron-Vertrieb GmbH