Školenie Mitsubishi Electric 2017 Ing. Martin Hanic
1. Nové dizajnové jednotky MSZ-LN (R32)
2. Nové jednotky PUMY – kombinácia ATA a ATW
3. Hybridný HVRF systém
Top novinky 2017
4. QAHV – Tepelné čerpadlo na CO2 ( až 90°°°°C)
5. E-séria – Chillery v ponuke Mitsubishi Electric
6. Nové kazety pre Mr.Slim a VRF
7. GUG – výparníky k jednotkám Lossnay
8. Partnerská zóna + E-Shop
MSZ-LN25/25/50/60VG/V/W/BR
• Nová vlajková loď od Mitsubishi Electric• I-See Sensor• Veľkosť 25/35/50/60 � Neu• 4 farby štandardná biela + biela, červená a čierna s vlasovým efektom• SEER A+++ / SCOP A+++• Nový Wifi modul je už integrovaný v jednotke• PLASMA QUAD PLUS filter
MSZ-LN – nové designové jednotky
• PLASMA QUAD PLUS filter• Chladivo R32 pre Single-Split jednotky (MUZ-LN_VG)• Vonkajšie jednotky aj s technológiou Hyper Heating
• City Multi PUMY vonkajšie jednotky
– City Multi 3 výkonové modely
• Kompaktné rozmery• 1- a 3- fázové napájanie• max. 12 vnútorných jednotiek na systém
17COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
• max. 12 vnútorných jednotiek na systém
PUMY-P112YKM2
PUMY-P125YKM2
PUMY-P140YKM2
PUMY-P200YKM2
Cooling capacity(kW)
12,5 14,0 15,5 22,4
Heating capacity(kW)
14,0 16,0 18,0 25
Indoor units 1-9 1-10 1-12 1-12
2 bis 8 IGM/Mr. Slim + 1 EcodanTotal 7 + 1 Ecodan
Max. 5 IG VRF
Systemaufbau
Max. 5 IG VRFMax. 4 IG M-Serie/Mr.Slim + 1 EcodanTotal 9 + 1 Ecodan
Max. 3 IG VRFMax. 7 IG M-Serie/Mr.Slim + 1 EcodanTotal 10 + 1 Ecodan
Hybrid BC Controller (HBC)
Refrigerant
Hybrid City MultiCombining direct expansion with chiller technology
Indoor units
Outdoor unit
Refrigerantpipe
Water piping
R2 Technologie – Sila a výzvy
Sila
• Efektívnosť prevádzky
• Rekuperácia tepla
• Design systému-inštalácia
• Komfortná inividuálna regulácia
Výzvy
• Množstvo chladiva vzhľadom na EN378 (� Hotelové aplikácie)
• Predpisy (F-Gas)
• Certifikácia budov (F-Gas - množstvo)
Hybrid City Multi
• Komfortná inividuálna regulácia
• Nezávislosť chladenia/kúrenia
• …
• Certifikácia budov (F-Gas - množstvo) BREEAM/LEED/DGNB
• Špecifické požiadavky užívateľa („chillerfriends“)
23COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIALCOPYRIGHT © 2016 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Hotel applicationIndividual cooling
and heating of every single room.
24COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
24
– No conflict with high refrigerant concentration (DIN 378) even in small rooms
– Comfortable with very low noise in opreation
– Individual control
HBC controller can be installed in a
technical room or storage.
Leistungscode P 15 P 20 P 25 P 32 P 40 P 50
Kälteleistung (kW) 1,7 2,2 2,8 3,6 4,5 5,6
Heizleistung (kW) 1,9 2,5 3,2 4,0 5,0 6,3
4-Wege-Deckenkassette
mit Coanda-Effekt
PLFY-WP VBM-E� � �
Truhengerät mit statischer
HVRF Indoor units
25COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
Truhengerät mit statischer
Pressung
PFFY-WP VLRMM-E� � � � �
Kanaleinbaugerät,
variable Durchströmung,
mittlere statische Pressung
PEFY-VMA-E
� � � � �
Kanaleinbaugerät, extra flache
Konstruktion
PEFY-WP VMS1-E� � � � � �
Leistungscode P 200 P 250 P 300 P 350 P 400 P 450 P 500
Kälteleistung (kW) 22,4 28,0 33,5 40,0 45,0 50,0 56,0
Heizleistung (kW) 25,0 31,5 37,5 45,0 50,0 56,0 63,0
PURY-EP
High SEER
HVRF Outdoor units
S S L L LXL
XL
26COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
High SEER
PURY-P
Standard
WR2-Serie
PQRY-P
Water cooled
L L
S S L LXL
XL
XL
S S S L L L L
HVRF Controller
• Master Controllermit 8 oder 16 Ports
27COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL 27
• Slave Controllermit 8 oder 16 Ports
HVRF Systemstructure
Outdoor unit
• PURY-EP – high seasonal efficiency
• PURY-P - standard• PQRY-P – water
cooled• Baugröße 200 -
500
• Slave Controller• one slave per
master• 8 or 16 Ports• Connected to
Master HBC via water piping
• Master Controller• 1-2 per
system• 8 or 16 Ports• Up to 40kW
Indoor unit capacity per controller Up to 60 m
From master controller
28COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL28
500 controller
or
Refrigerant piping R410A
Water connection
4x DN20
Up to 60m from Master controller
From master controller (a + b)
(a) (b)
VRF/Hybrid VRF at its best …
FUTURE-PROOFHIGH
29COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL 29
PROOF
withrefrigerant and
water
HIGH COMFORT
for the user
EFFICIENT
in operation
SIMPLE
to install
QAHV kompaktné tepelné čerpadlo na CO2
30COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
CO2 heat pump QAHVHot water heat pump with CO2 refrigerantHot water supply with temperatures up to 90°C at outside temperature up to -25°C 40kW capacityCO2 refrigerant with GWP of 1 (Global Warming Potential)
31COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
31
CO2 refrigerant with GWP of 1 (Global Warming Potential)
High efficiency, COP 4.1Combination with Mr Slim and VRF systems possibleCompatible with ModBUSAvailbale from March 2017
Transcritical CO2 heat pump
CO2 (R744)HFC (R410a)
Refrigerant type versus type of heat exchanger
Superior in
performance when
the ΔT is big
Superior in
performance when
the ΔT is small
Why is the QAHV heat pump so efficient?
34COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
34
Product Outline
EAHV/EACV-P900 Chiller (e-series)
■EAHV/EACV-P900YA(-H) (30HP single module only)* EAHV>>Heat pump, EACV>>cooling only, EAHV-H>>Heating Only
**Module combination up to 180HP (6 modules)
■Features
1. High efficiency
>>EER 3.30 / ESEER 4,71 **1
2. Small installation space2. Small installation space
>>Can be installed in narrow & small space
(Module can be installed within 2.55m depth)
3. Easy to design and install
>>Water piping, electrical wiring pump etc,
4. Low Operation Sound
5. Wide Water Temp Range
>>Cooling : 5C to 25 C, Heating :30C to 55C
6. Inverter Driven Compressor & Fan motor
**1 (Inclues pump input based on EN14511)
38
1.High efficiency
U-shaped high performance compact air HEXDC fan motor
Adopting high efficincy key devises to achieve excellent energy saving performance
INV scroll comp. Inflexed fan
e-series Prodcut features
Achieved EER 3.30 and COP 3.50
Japan domestic model photo
fan rear edge
2.Small footprint installation
e-series Prodcut features
①①①①Example of installation along the outer wall of factory ③③③③ Double-row installation
40COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL 40
②②②②Double-stack installation
Standard Specifications
InletOutlet
inletOutlet
30HP Module
30HP Module
Number of pump: 6Number of water pipe connection: 12
Reduce pump and Reduce pump and connetion pipe
In case of 6-module connection (30HP×6 units)3.Inside headerspecifications
e-series Prodcut features
inlet
InletOutletInside header pipe
Inside Header Specifications
Number of pump:1Number of water pipe connection :2
(inside joint: 10)Only
MELCO
Less work for pump and water piping
installation as header piping is inside of unit
connetion pipeconnetion pipe
Confidential
Product Lineup
EAHV/EACV-P900 Chiller (e-series)
42
HP 30HP 60HP 90HP 120HP 150HP 180HP
EACV/EAHV P900YA P1800YA P2700YA P3600YA P4500YA P5400YA
Number of Module(30HP) 1 2 3 4 5 6
Capacity(kW) 90kW 180kW 270kW 360kW 450kW 540kW
Module combination
New Cassette New Cassette forfor City Multi und City Multi und Mr.SlimMr.Slim
-- PLFYPLFY--P VEMP VEM
-- PLAPLA--ZM EAZM EA
PLFYPLFY--B VBM B VBM andand PLAPLA--(Z)RP will (Z)RP will bebe replacedreplaced
44
Better air distribution New 3D i-see sensor
New promotion points
Design comparison
45
Nicer panel design
and
new colour
Efficiency improvement
1. What is the Dx-coil unit?
Connected to theLossnay supply air duct.
Control the temperature by two kind of features; Return air temperature controlor Supply air temperature control.
Supply air
51
Outdoor air
Working with Mr. Slim power inverter series, PUHZ-ZRP.
Dx-coil unit
Lossnay unit
Outdoor unit
Return air
1. What is the Dx-coil unit?
Two temperature control features
As same as air conditioner, users set the target return air temperature on the remote controller and then Dx-coil unit will operate to heat up or cool down the room temperature.
RA (Return Air) temperature control
Target temperature
52
Setting temperature
1. What is the Dx-coil unit?
Two temperature control features
Users set the target supply air temperature on the remote controller and then Dx-coil unit will maintain the supply air temperature close to the setting temperature.
SA (Supply Air) temperature control
Target temperature
53
Setting temperature
1. What is the Dx-coil unit?
Application examples
54Supplemental air-conditioning systems that combine the use of Dx-coil and Lossnay units.
Specification of Dx-coil unit
Model
Connection Brief Specification
Lossnay
RA (Return Air) temperature control SA (Supply Air) temperature control
Heat Resource CapacityPerformance
indexHeat Resource Capacity
Performance index
GUG-01SL-ELGH-50RVX PUHZ-ZRP35
Heating 6.5 ( 2.4 + 4.1 ) 4.09Cooling 5.6 ( 2.0 + 3.6 ) 4.69
LGH-65RVX PUHZ-ZRP35Heating 7.7 ( 3.2 + 4.5 ) 4.72Cooling 6.6 ( 2.6 + 4.0 ) 5.73
GUG-02SL-ELGH-80RVX PUHZ-ZRP50
Heating 10.0 ( 4.0 + 6.0 ) 4.62PUHZ-ZRP50
10.0 ( 4.0 + 6.0 ) 4.62Cooling 8.3 ( 3.3 + 5.0 ) 4.76 8.3 ( 3.3 + 5.0 ) 4.76
LGH-100RVX PUHZ-ZRP71Heating 13.2 ( 5.1 + 8.1 ) 4.42
PUHZ-ZRP5011.4 ( 5.1 + 6.3 ) 5.09
Cooling 11.3 ( 4.2 + 7.1 ) 4.98 9.5 ( 4.2 + 5.3 ) 5.43
3. Specification
55COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL
The first figure in ( ) of the capacity specification is the heat recovery energy of the Lossnay unit. The second figure is the capacity specification for the Dx-coil connected to the outdoor unit.
Heating conditions: Indoor 20DB/13.8WB, Outdoor 7DB/6WBCooling conditions: Indoor 27DB/19WB, Outdoor 35DB/24WB
”Performance index” is the calculated value at the temperature conditions above and is reference purpose only.Performance index = Total capacity ÷ total power consumption of outdoor unit and Lossnay unitNote: Dx-coil unit is NOT an air conditioning indoor unit and does NOT have “Energy Efficiency Class”. 5
5
LGH-100RVX PUHZ-ZRP71 PUHZ-ZRP50Cooling 11.3 ( 4.2 + 7.1 ) 4.98 9.5 ( 4.2 + 5.3 ) 5.43
GUG-03SL-E
LGH-150RVX PUHZ-ZRP100Heating 20.7 ( 7.7 + 13.0 ) 4.24
PUHZ-ZRP7116.6 ( 7.7 + 8.9 ) 5.46
Cooling 15.8 ( 6.3 + 9.5 ) 5.27 13.4 ( 6.3 + 7.1 ) 5.32
LGH-200RVX PUHZ-ZRP100Heating 23.8 ( 10.3 + 13.5 ) 5.02
PUHZ-ZRP7119.5 ( 10.3 + 9.2 ) 6.3
Cooling 18.4 ( 8.4 + 10.0 ) 5.86 15.9 ( 8.5 + 7.4 ) 5.85
LGH-150RVXT PUHZ-ZRP100Heating 20.4 ( 7.4 + 13.0 ) 4.07
PUHZ-ZRP7116.3 ( 7.4 + 8.9 ) 5.16
Cooling 15.7 ( 6.2 + 9.5 ) 5.03 13.3 ( 6.2 + 7.1 ) 5.03
LGH-200RVXT PUHZ-ZRP100Heating 23.8 ( 10.3 + 13.5 ) 4.86
PUHZ-ZRP7119.5 ( 10.3 + 9.2 ) 6.01
Cooling 18.4 ( 8.4 + 10.0 ) 5.59 15.9 ( 8.5 + 7.4 ) 5.54
LGH-250RVXT PUHZ-ZRP125Heating 26.1 ( 12.1 + 14.0 ) 4.75
PUHZ-ZRP7121.6 ( 12.1 + 9.5 ) 5.97
Cooling 22.3 ( 9.8 + 12.5 ) 4.59 17.6 ( 9.8 + 7.8 ) 5.31
Nové jednotky Zubadan a Power Inverter 8 a 11,2 kW
-Znížená hlučnosť až o 10 dB
-Znížené vibrácie
-Nová konštrukcia jednotiek
Lossnay VL-100 – lokálna rekuperačná jednotka
57COPYRIGHT © 2010 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.CONFIDENTIAL 57
Postup pri registrácii do partnerskej sekcie:
1. Zaregistrujte sa na stránke http://partners.vykuruj.sk/registraciavyplnením všetkých údajov a zaškrtnutím súhlasu s obchodnýmipodmienkami.
2. Príde Vám e-mail s oznámením o úspešnej registrácii. Treba počkať naaktiváciu Vášho konta z našej strany.
3. Po úspešnej aktivácii Vám príde e-mail „Váš účet bol aktivovaný“.
E-shop pre partnerov
3. Po úspešnej aktivácii Vám príde e-mail „Váš účet bol aktivovaný“.Pokračujte prihlásením na http://partners.vykuruj.sk/login zadaním svojhoe-mailu a hesla zvoleného pri registrácii.
4. Po prihlásení sa zobrazia Obchodné podmienky. Pokračujte kliknutímna „Súhlasím s obchodnými podmienkami“.
5. Budete presmerovaní do sekcie „Správy“, kde nájdete kategórie:Prospekty a katalógy, Software, Databooky, Katalógové listy – inštalačnédáta, Návody na obsluhu, DXF podklady pre projektantov a Servisnémanuály.