CODE OPTIONS CSD-1 STANDARD KN-6 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information) SKN-6DF-4 71 17/32 1817 35 1/8 892 32 1/16 814 12 9/16 319 25 635 2X 1 1/32 26 8 1/32 204 18 21/32 474 32 15/16 837 14 29/32 378 15 1/8 384 CONDENSATE DRAIN 3/4 HOSE BARB 1 NPT L.P. INLET 1 NPT N.G. INLET WIRING CONNECTIONS 3 5/32 80 9 11/16 246 44 9/16 1132 3 5/32 80 TOP VIEW ASUB-31_D 2 1/2 64 20 508 25 635 1 3/4 44 4X 5/8 16 BOTTOM VIEW ASUB-31_D 3 7/32 82 12 1/2 318 17 11/32 441 21 13/16 554 21 5/8 549 9 1/8 232 20 1/2 521 46 15/16 1192 13 1/4 336 64 13/32 1636 3 NPT BOILER OUTLET 3 NPT BOILER INLET BOILER DRAIN VALVE 4 FLUE OUTLET 6 AIR INLET FRONT VIEW ASUB-31_D SIDE VIEW ASUB-31_D REAR VIEW ASUB-31_D NOTES: 1. SYMBOL INDICATES CENTER OF GRAVITY. 2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN". 3. ALL DIMENSIONS ARE INCHES [mm].
14

KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

Mar 14, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-6 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-6DF-4

71 17/321817

35 1/8892

32 1/16814

12 9/16319

25635

2X 1 1/3226

8 1/32204

18 21/32474

32 15/16837

14 29/32378

15 1/8384

CONDENSATE DRAIN3/4 HOSE BARB

1 NPTL.P. INLET

1 NPTN.G. INLET

WIRINGCONNECTIONS

3 5/3280

9 11/16246

44 9/161132

3 5/3280

TOP VIEWASUB-31_D

2 1/264

20508

25635

1 3/444

4X 5/816

BOTTOM VIEWASUB-31_D

3 7/3282

12 1/2

318

17 11/32441

21 13/16554

21 5/8549

9 1/8232

20 1/2521

46 15/161192

13 1/4336

64 13/321636

3 NPTBOILER OUTLET

3 NPTBOILER INLET

BOILERDRAINVALVE

4FLUE OUTLET

6 AIR INLET

FRONT VIEWASUB-31_D

SIDE VIEWASUB-31_D

REAR VIEWASUB-31_D

NOTES: 1. SYMBOL INDICATES CENTER OF GRAVITY. 2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".3. ALL DIMENSIONS ARE INCHES [mm].

Page 2: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-6 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 13.1 A*

Input BTU/hr. 600 MBH / 176 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 540 MBH / 158 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 16.3 Water Volume 7.9 gal.

Electrical Requirements 120VAC/ 60 hz/ 1PH Operating Weight 1150 lbs. / 522 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit Honeywell L4006E L.W.C.O. 800

Main Ball Valve 1" Apollo Relief Valve 30, 50, 75 & 100 PSI

Pilot Cock 1/4" Conbraco Pilot Regulator Maxitrol RV12LT

A.S.M.E.ASME Sect IV Fire Side Htg Surface 21.18 Sq. Ft. / 1.97 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 21.32 Sq. Ft. / 1.98 Sq. M.

CV. GPM (1PSID) 62

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

54.0 3.40 1.75 5.20 27.0 1.70 .44 1.30 18.0 1.10 .19 .60 13.5 .90 .11 .30 10.8 .70 .07 .20

SKN-6DF-4

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

10.8 54.0 20 100 6 120 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.

Page 3: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-10 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-10DF-4

35 1/8892

12 1/2317

25635

32 3/32815

71 17/321817

2X 13/1620

8 1/32204

18 21/32474

14 23/32

373

18 15/32469

CONDENSATE DRAIN3/4 HOSE BARB

1 NPTL.P. INLET

1 NPTN.G. INLET

WIRINGCONNECTIONS

3 5/3280

3 5/3280

52 1/321321

TOP VIEWASUB-30_D

20508

1 3/444

32 1/8816

2 1/264

4X 5/816

BOTTOM VIEWASUB-30_D

9 1/8232

20 1/2521

46 15/161192

21 5/8549

3 7/3282

12 1/2318

17 11/32441

21 13/16554

64 13/321636

13 1/4336

3 NPTBOILER OUTLET

3 NPTBOILER INLET

BOILERDRAINVALVE

4FLUE OUTLET

6 AIR INLET

FRONT VIEWASUB-30_C

SIDE VIEWASUB-30_D

REAR VIEWASUB-30_D

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY. 2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN". 3. ALL DIMENSIONS ARE INCHES [mm].

Page 4: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-10 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 13.1 A*

Input BTU/hr. 1000 MBH / 293 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 900 MBH / 264 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 26.9 Water Volume 11.9 gal.

Electrical Requirements 120VAC/ 60 hz/ 1PH Operating Weight 1557 lbs. / 707 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1 1/4" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit Honeywell L4006E L.W.C.O. 800

Main Ball Valve 1 1/4" Apollo Relief Valve 30, 50, 75 & 100 PSI

Pilot Cock 1/4" Conbraco Pilot Regulator Maxitrol RV12LT

A.S.M.E.ASME Sect IV Fire Side Htg Surface 34.48 Sq. Ft. / 3.20 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 35.54 Sq. Ft. / 3.30 Sq. M.

CV. GPM (1PSID) 100

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

90.0 5.70 1.87 5.60 45.0 2.80 .47 1.40 30.0 1.90 .21 .60 22.5 1.40 .12 .30 18.0 1.10 .07 .20

SKN-10DF-4

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

18.0 90.0 20 100 6 120*** 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.***A maximum equivalent length of 80 ft. utilizing 4" vent diameter and 120 ft. utilizing 5" vent diameter.

*Add circulator amps.

Page 5: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-16 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-16DF-4

32 3/8822

12 1/2316

25635

34 31/32888

71 3/81813

7 7/16189

18 7/8480

1 7/3231

23581

CONDENSATE DRAIN3/4 HOSE BARB

1 1/2 NPTL.P. INLET

1 1/2 NPTN.G. INLET

WIRINGCONNECTIONS

61 7/321555

2 25/3270

2 25/3270

TOP VIEWASUB-29_D

2 1/264

20508

1 3/444

43 1/41099

4X 5/816

BOTTOM VIEWASUB-29_D

21 13/16554

46 15/161192

20 1/2521

9 1/8232

21 5/8549

3 7/3282

12 1/2318

17 11/32441

9 15/32241

65 7/321657

3 NPTBOILEROUTLET

3 NPTBOILER INLET

BOILERDRAINVALVE

6FLUEOUTLET

8 AIR INLET

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY.

2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".

3. ALL DIMENSIONS ARE INCHES [mm].

SIDE VIEWASUB-29_D

REAR VIEWASUB-29_D

FRONT VIEWASUB-29_D

Page 6: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-16 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 13.1 A*

Input BTU/hr. 1600 MBH / 469 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 1440 MBH / 422 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 43.0 Water Volume 17.9 gal.

Electrical Requirements 230VAC/60 hz/1PH (with neutral) Operating Weight 2360 lbs. / 1070 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1-1/2" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit Honeywell L4006E L.W.C.O. 800

Main Ball Valve 1-1/2" Apollo Relief Valve 30, 50, 75 & 100 PSI

Pilot Cock 1/4" Conbraco Pilot Regulator Maxitrol RV12LT

A.S.M.E.ASME Sect IV Fire Side Htg Surface 54.43 Sq. Ft. / 5.06 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 56.86 Sq. Ft. / 5.28 Sq. M.

CV. GPM (1PSID) 140

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

144.1 9.10 2.44 7.30 72.0 4.50 .61 1.80 48.0 3.00 .27 .80 36.0 2.30 .15 .50 28.8 1.80 .10 .30

SKN-16DF-4

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

28.8 144.1 20 100 6 120 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.

Page 7: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-20 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-20DF-4

34 29/32886

12 13/32315

25635

32 13/32823

71 29/321826

2X 125

7 15/16202

19 13/32493

26 1/4667

CONDENSATE DRAIN3/4 HOSE BARB

1 1/2 NPTL.P. INLET

1 1/2 NPTN.G. INLET

WIRINGCONNECTIONS

68 11/161744

2 25/3270

2 25/3270

TOP VIEWASUB-28_D

50 3/81280

1 3/444

20508

2 1/264

4X 5/816

BOTTOM VIEWASUB-28_D

9 1/8232

20 1/2521

46 15/161192

21 5/8549

3 7/3282

12 1/2318

17 11/32441

21 13/16554

9 3/8238

65 23/321670

3 NPTBOILEROUTLET

3 NPTBOILER INLET

BOILERDRAINVALVE

6FLUEOUTLET

8 AIR INLET

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY.

2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".

3. ALL DIMENSIONS ARE INCHES [mm].

FRONT VIEWASUB-28_D

SIDE VIEWASUB-28_D

REAR VIEWASUB-28_D

Page 8: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-20 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 13.1 A*

Input BTU/hr. 1999 MBH / 586 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 1799 MBH / 527 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 53.7 Water Volume 21.9 gal.

Electrical Requirements 230VAC/60 hz/1PH (with neutral) Operating Weight 2714 lbs. / 1232 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1-1/2" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit Honeywell L4006E L.W.C.O. 800

Main Ball Valve 1-1/2" Apollo Relief Valve 30, 50, 75 & 100 PSI

Pilot Cock 1/4" Conbraco Pilot Regulator Maxitrol RV12LT

A.S.M.E.ASME Sect IV Fire Side Htg Surface 67.72 Sq. Ft. / 6.29 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 71.08 Sq. Ft. / 6.60 Sq. M.

CV. GPM (1PSID) 161

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

180.0 11.40 2.88 8.60 90.0 5.70 .72 2.20 60.0 3.80 .32 1.00 45.0 2.80 .18 .50 36.0 2.30 .12 .30

SKN-20DF-4

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

36.0 180.0 20 100 6 120 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.

Page 9: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-26 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-26DF-6

34 9/32871

71 29/321826

25635

32809

12 1/2314

2X 126 7 15/16

202

19 13/32493

802032

32 13/32823

CONDENSATE DRAIN3/4 HOSE BARB

1 1/2 NPTL.P. INLET

1 1/2 NPTN.G. INLET

WIRINGCONNECTIONS

6 31/32177

6 31/32177

TOP VIEWASUB-27_E

2 1/264

20508

62 5/161583

1 3/444

4X 5/816

BOTTOM VIEWASUB-27_E

9 1/8232

20 1/2521

46 1/161170

21 5/8549

3 27/3298

12 1/2318

17 11/32441

21 7/32539

8 AIR INLET 9 3/8238

65 23/321670

4" ANSI FLANGEBOILER OUTLET

4" ANSI FLANGEBOILER INLET

BOILERDRAINVALVE

8FLUE OUTLET

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY.

2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".

3. ALL DIMENSIONS ARE INCHES [mm].

FRONT VIEWASUB-27_E

SIDE VIEWASUB-27_E

REAR VIEWASUB-27_E

Page 10: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-26 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 10.7 A*

Input BTU/hr. 2600 MBH / 762 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 2340 MBH / 686 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 70 Water Volume 27.7 gal.

Electrical Requirements 230VAC/60 hz/3PH Operating Weight 3425 lbs. / 1555 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1-1/2" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit (Manual Reset) Honeywell L4006E L.W.C.O. 800

High Limit (Auto Reset) Honeywell L4006A Relief Valve 30, 50, 75 & 100 PSI

Main Ball Valve 1-1/2" Apollo Pilot Regulator Maxitrol RV12LT

Pilot Cock 1/4" Conbraco

A.S.M.E.ASME Sect IV Fire Side Htg Surface 87.69 Sq. Ft. / 8.15 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 92.41 Sq. Ft. / 8.59 Sq. M.

CV. GPM (1PSID) 222

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

234.1 14.80 2.57 7.70 117.0 7.40 .64 1.90 78.0 4.90 .29 .90 58.5 3.70 .16 .50 46.8 3.00 .10 .30

SKN-26DF-6

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

46.8 234.1 20 100 6 120 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.

Page 11: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-30 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-30DF-6

71 29/321826

25635

12 1/2314

32809

34 9/32871

19 13/32493

7 15/16202

2X 1 1/3226

36916

CONDENSATE DRAIN3/4 HOSE BARB

1 1/2 NPTL.P. INLET

1 1/2 NPTN.G. INLET

WIRINGCONNECTIONS

6 31/32177

87 9/322217

6 31/32177

TOP VIEWASUB-26_E

1 3/444

69 11/161770

20508

2 1/264

4X 5/816

BOTTOM VIEWASUB-26_E

21 5/8549

3 27/3298

12 1/2318

17 11/32441

21 7/32539

9 1/8232

20 1/2521

46 1/161170

65 23/321670

9 3/8238

4" ANSI FLANGEBOILER OUTLET

4" ANSI FLANGEBOILER INLET

BOILERDRAINVALVE

8FLUE OUTLET

8 AIR INLET

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY.

2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".

3. ALL DIMENSIONS ARE INCHES [mm].

FRONT VIEWASUB-26_E

SIDE VIEWASUB-26_E

REAR VIEWASUB-26_E

Page 12: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-30 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 10.7 A*

Input BTU/hr. 3000 MBH / 879 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 2700 MBH / 791 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 80.7 Water Volume 31.7 gal.

Electrical Requirements 230VAC/60 hz/3PH Operating Weight 3850 lbs. / 1748 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 1-1/2" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit (Manual Reset) Honeywell L4006E L.W.C.O. 800

High Limit (Auto Reset) Honeywell L4006A Relief Valve 30, 50, 75 & 100 PSI

Main Ball Valve 1-1/2" Apollo Pilot Regulator Maxitrol RV12LT

Pilot Cock 1/4" Conbraco

A.S.M.E.ASME Sect IV Fire Side Htg Surface 100.98 Sq. Ft. / 9.38 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 106.63 Sq. Ft. / 9.91 Sq. M.

CV. GPM (1PSID) 246

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

270.1 17.0 2.78 8.30 135.1 8.50 .70 2.10 90.0 5.70 .31 .90 67.5 4.30 .17 .50 54.0 3.40 .11 .30

SKN-30DF-6

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

54.4 270.1 20 100 6 120 0 120

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.

Page 13: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

CODE OPTIONS

CSD-1 STANDARDKN-40 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

SKN-40DF-2

73 15/321866

34 3/8873

30 15/16786

25635

12 13/32315

3 3/3278

7 25/32198

14 11/16373

16 13/16427

3 11/3285

41 9/161056

CONDENSATE DRAIN3/4 HOSE BARB

1 1/2 NPTL.P. INLET

2 NPTN.G. INLET

WIRINGCONNECTIONS

7 5/16186

7 5/16186

107 7/322724

TOP VIEWASUB-00039_B

1 3/444

84 3/42153

2 1/264

20508

4X 5/816

BOTTOM VIEWASUB-00039_B

9 1/8232

11 3/4299

21 13/32544

21 3/8543

66 5/161684

45 27/321165

21 7/32539

17 11/32441

12 1/2318

3 27/3298

4" ANSI FLANGEBOILER OUTLET

4" ANSI FLANGEBOILER INLET

BOILERDRAINVALVE

12 AIR INLET

10 FLUEOUTLET

NOTES:

1. SYMBOL INDICATES CENTER OF GRAVITY.

2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN".

3. ALL DIMENSIONS ARE INCHES [mm].

FRONT VIEWASUB-00039_B

SIDE VIEWASUB-00039_B

REAR VIEWASUB-00039_B

Page 14: KN-6 - Dual Fuelliterature.mestek.com/dms/Hydrotherm Boilers/KN Series...KN-16 - Dual Fuel Category II or Category IV Appliance (see Installation and Operation Manual for venting information)

REP FIRM

SUBMITTED BY

JOB NAME

ARCHITECT

ENGINEER

CONTRACTOR

DATE

KN-40 - Dual FuelCategory II or Category IV Appliance

(see Installation and Operation Manual for venting information)

A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515

A.G.A. CERTIFIED RATINGS & CAPACITIESFuel Type Natural/LP Gas Boiler FLA 14.9 A*

Input BTU/hr. 4000 MBH / 1172 KW Min. Gas Pressure Required 3" W.C.

Output BTU/hr. 3540 MBH / 1037 KW Max. Gas Pressure Allowed 14" W.C.

Boiler HP 105.8 Water Volume 41.6 gal.

Electrical Requirements 230VAC/60 hz/3PH Operating Weight 4627 lbs. / 2101 kg.

SCCR Rating 5kA

BOILER TRIM & CONTROLSMain Gas Valve Dungs MBC Air Switch Huba

Firing Valve 2" Apollo Flow Sensor SIKA

Ignition Control Honeywell RM7895C Blocked Flue Switch Cleveland NS2

Operating Control HeatNet® Blower Motor Ametek

High Limit (Manual Reset) Honeywell L4006E L.W.C.O. 800

High Limit (Auto Reset) Honeywell L4006A Relief Valve 30, 50, 75 & 100 PSI

Main Ball Valve 2" Apollo Pilot Regulator Maxitrol RV12LT

Pilot Cock 1/4" Conbraco

A.S.M.E.ASME Sect IV Fire Side Htg Surface 134.23 Sq. Ft. / 12.47 Sq. M. Design Data 100 PSI & 250°F

ASME Sect IV Water Side Htg Surface 142.17 Sq. Ft. / 13.21 Sq. M.

CV. GPM (1PSID) 271

TEMPERATURE RISE / PRESSURE DROP (Based on Full Input)20°F / 11.1°C 40°F / 22.2°C 60°F / 33.3°C 80°F / 44.4°C 100°F / 55.5°C

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

DropFlow Rate

Pressure Drop

Flow RatePressure

Drop

GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa

354.1 22.3 3.94 11.8 177.1 11.2 .99 2.90 118.0 7.40 .44 1.30 88.5 5.60 .25 .70 70.8 4.50 .16 .50

SKN-40DF-2

Flow GPM Temp. Rise** (°F) Vent Length (Equiv. Ft.) Air Inlet Length (Equiv. Ft.)

Min Max Min Max Min Max Min Max

70.8 354.1 20 100 6 100 0 100

**Min/Max delta t reflects boiler operation at full input. For applications requiring operation above/below these parameters please consult factory.

*Add circulator amps.