www.schunk.com 14 Technical data Moment load KLM 300 Linear modules · Pneumatic · Stroke module Designation KLM 300-H050 KLM 300-H100 KLM 300-H150 KLM 300-H200 KLM 300-H250 KLM 300-H300 ID 0314550 0314554 0314558 0314562 031 4566 03 14570 Stroke length [mm] 50 100 150 200 250 300 Extend force [FV] at 6 bar [N] 753 753 753 753 753 7 53 Retract force [FR] at 6 bar [N] 633 633 633 633 633 633 Piston diameter [mm] 40 40 40 40 40 40 Rod diameter [mm] 1 6 16 16 16 16 16 Overall length [mm] 324 32 4 52 4 52 4 724 724 Mass [kg] 6.9 6.8 9.8 9.7 12.7 12.6 Fluid consumption/1 0 mm stroke [cm³] 12.57 12.57 12.57 12.57 12.57 12.57 Minimum pressure [bar] 3 3 3 3 3 3 Maximum pressure [bar] 8 8 8 8 8 8 Nominal operating pressure [bar] 6 6 6 6 6 6 IP rating 40 40 40 40 40 40 Min. ambient temperature [°C] 5 5 5 5 5 5 Max. ambient temperature [°C] 60 60 60 60 60 60 Repeat accuracy [mm] ± 0.015 ± 0.015 ± 0.015 ± 0.01 5 ± 0.01 5 ± 0.01 5 OPTIONS and their characteristics Dust-protection version ID 0314552 0314556 031 4560 03 14564 0314568 031 4572 Designation KLM 300-H050- SD KLM 30 0-H100- S D K L M 30 0- H150 - SD KLM 300-H200-SD KLM 300-H250-SD KLM 300-H300-SD IP rating 64 64 64 64 64 64 Rod lock ID 031 4551 0314555 0314559 0314563 031456 7 031 4571 Designation KLM 300-H050-A SP KLM 3 00 -H100-A SP KL M 3 00 - H150-A S P KLM 300-H200-ASP KLM 300-250-ASP KLM 300-H300-ASP Stroke loss of nominal stroke (on the rod side) [mm] 22 22 22 22 22 22 Mayy [kg] 7.4 7.3 10.3 1 0.2 13.2 1 3.1 Static holding force [N] 1000 1000 1000 1 000 1 000 1 000 max. axial backlash of the clamping [mm] 0.25 0.25 0.25 0.25 0.25 0.25 ZZA intermediate stop on the rod side possible Yes Y es Y es Y es Y es Yes ZZA intermediate stop side on the piston possible Yes Y es Y es Y es Y es Yes LMZAW intermedite stop possible No No No No No No Designation F y  /F z M x M y M z [N] [Nm] [Nm] [Nm] KLM 300-H050 3120 90 200 200 KLM 300-H100 3120 90 200 200 KLM 300-H150 2490 72 350 350 KLM 300-H200 2490 72 350 350 KLM 300-H250 1870 54 415 415 KLM 300-H300 1870 54 415 415 L = 61 mm  The forces and moments shown here are maximum values for individual loading. If more than one force or moment occurs simultaneously, the application can be calculated by the TOOLBOX sizing software.
5

KLM_300_EN

Jun 03, 2018

Download

Documents

vikas_ojha54706
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: KLM_300_EN

8/12/2019 KLM_300_EN

http://slidepdf.com/reader/full/klm300en 1/4w w w . s c h u n k . c o m14

Technical data

Moment load

KLM 300Linear modules · Pneumatic · Stroke module

Designation KLM 300-H050 KLM 300-H100 KLM 300-H150 KLM 300-H200 KLM 300-H250 KLM 300-H300

ID 0314550 0314554 0314558 0314562 0314566 0314570

Stroke length [mm] 50 100 150 200 250 300

Extend force [FV] at 6 bar [N] 753 753 753 753 753 753

Retract force [FR] at 6 bar [N] 633 633 633 633 633 633Piston diameter [mm] 40 40 40 40 40 40

Rod diameter [mm] 16 16 16 16 16 16

Overall length [mm] 324 324 524 524 724 724Mass [kg] 6.9 6.8 9.8 9.7 12.7 12.6

Fluid consumption/10 mm stroke [cm³] 12.57 12.57 12.57 12.57 12.57 12.57

Minimum pressure [bar] 3 3 3 3 3 3Maximum pressure [bar] 8 8 8 8 8 8

Nominal operating pressure [bar] 6 6 6 6 6 6

IP rating 40 40 40 40 40 40Min. ambient temperature [°C] 5 5 5 5 5 5

Max. ambient temperature [°C] 60 60 60 60 60 60

Repeat accuracy [mm] ± 0.015 ± 0.015 ± 0.015 ± 0.015 ± 0.015 ± 0.015OPTIONS and their characteristics

Dust-protection version ID 0314552 0314556 0314560 0314564 0314568 0314572

Designation KLM 300-H050-SD KLM 300-H100-SD KLM 300-H150-SD KLM 300-H200-SD KLM 300-H250-SD KLM 300-H300-SD

IP rating 64 64 64 64 64 64

Rod lock ID 0314551 0314555 0314559 0314563 0314567 0314571

Designation KLM 300-H050-ASP KLM 300-H100-ASP KLM 300-H150-ASP KLM 300-H200-ASP KLM 300-250-ASP KLM 300-H300-ASP

Stroke loss of nominal stroke (on the rod side) [mm] 22 22 22 22 22 22

Mayy [kg] 7.4 7.3 10.3 10.2 13.2 13.1

Static holding force [N] 1000 1000 1000 1000 1000 1000

max. axial backlash of the clamping [mm] 0.25 0.25 0.25 0.25 0.25 0.25ZZA intermediate stop on the rod side possible Yes Yes Yes Yes Yes Yes

ZZA intermediate stop side on the piston possible Yes Yes Yes Yes Yes Yes

LMZAW intermedite stop possible No No No No No No

Designation Fy /Fz Mx My Mz

[N] [Nm] [Nm] [Nm]

KLM 300-H050 3120 90 200 200KLM 300-H100 3120 90 200 200

KLM 300-H150 2490 72 350 350

KLM 300-H200 2490 72 350 350

KLM 300-H250 1870 54 415 415KLM 300-H300 1870 54 415 415

L = 61 mm

 The forces and moments shown here are maximum valuesfor individual loading. If more than one force or moment

occurs simultaneously, the application can be calculated bythe TOOLBOX sizing software.

Page 2: KLM_300_EN

8/12/2019 KLM_300_EN

http://slidepdf.com/reader/full/klm300en 2/4 V e r k a u f k + 4 9 - 7 1 3 3 - 1 0 3 - 2 5 0 3 · T e c h n i k k + 4 9 - 7 1 3 3 - 1 0 3 - 2 6 9 6 15

KLM 300Linear modules · Pneumatic · Stroke module

You can find further information and components for the accessories mentioned here in the “Accessories” part of the catalog.

Main views, KLM 300-H100

Stroke variants

A, a Main and direct connections, extend linear unit

B, b Main and direct connections, retract linear unit1  Connection, linear unit2  Connection of the assembly  On both attachment faces  Back   Through-bores in the face plate and thread in the base body (only single sided)  Sensors and shock absorbers can also be fastened to the back. For variant H025, the sensors, shock

absorbers, and the air connections have to be fastened crosswise.

 Type Stroke A B C D E G[mm] [mm] [mm] [mm] [mm] [mm] [mm]

KLM 300-H050 50 324 1x50 4x25 27…77 170 127…77KLM 300-H100 100 324 1x50 4x25 27…127 170 127…27

KLM 300-H150 150 524 3x50 8x25 27…177 270 227…77

KLM 300-H200 200 524 3x50 8x25 27…227 270 227…27KLM 300-H250 250 724 5x50 12x25 27…277 370 327…77

KLM 300-H300 300 724 5x50 12x25 27…327 370 327…27

Variable dimensions of stroke variants

The linear module can be fastened either to the base body or the face plates. Thestructure can also optionally be fastened to either the face plates or the base body.This view shows the mounting of the module to the base body and the mounting ofthe structure to the face plates.

Not all dimensions shown can be seen in the main view.

Page 3: KLM_300_EN

8/12/2019 KLM_300_EN

http://slidepdf.com/reader/full/klm300en 3/4

Page 4: KLM_300_EN

8/12/2019 KLM_300_EN

http://slidepdf.com/reader/full/klm300en 4/4 V e r k a u f k + 4 9 - 7 1 3 3 - 1 0 3 - 2 5 0 3 · T e c h n i k k + 4 9 - 7 1 3 3 - 1 0 3 - 2 6 9 6 17

KLM 300Linear modules · Pneumatic · Stroke module

Inductive attachment, NHS

Intermediate stop, ZZA on the piston side Intermediate stop, ZZA on the piston rod side

  Air connection  Intermediate stroke  Overall length “A”, the variant without intermediate stroke (see dimension table of stroke variants)

ZZA 305

Holding force at 6 bar [N] 460

Additional mass at 0 mm stroke [kg] 0.75Additional mass per mm stroke [kg] 0.006

Sample order KLM 300-H100-ZZA305-H100

The intermediate position is measured from the respective end position. Theintermediate position can be approached from both sides and can proceed in theoriginal stroke direction.. The holding force is the piston force of the intermediatestop less the piston force of the linear module.

  Air connection  Intermediate stroke  Overall length “A”, the variant without intermediate stroke (see dimension table of stroke variants)

ZZA 306

Holding force at 6 bar [N] 460

Additional mass at 0 mm stroke [kg] 0.75Additional mass per mm stroke [kg] 0.006

Sample order KLM 300-H100-ZZA306-H100

The intermediate position is measured from the respective end position. Theintermediate position can be approached from both sides and can proceed in theoriginal stroke direction.. The holding force is the piston force of the intermediatestop less the piston force of the linear module.

End-position monitoring: Inductive proximity switch, can be directly mounted

Designation ID

NI 30-KT 0313429

Extension cable for proximity switch

Designation ID

KA-BG08-L 3P-0500-PNP 0301623

KA BW08-L 3P-0500-PNP 0301502

 Generally, two sensors are needed for each linear unit. For additional monitoring of the inter-mediate positions, one sensor per additional position as well as (optionally) one extension