KL Office : No.9-1 & 9-2, Jalan Puteri 5/20, Bandar Puteri, 47100 Puchong, Selangor MALAYSIA Tel : +603-80601222, +603-8061112, +80601100 Fax : +603-80601212 Website : www.southerncable.cc Email : [email protected]Head Office & Factory : Lot 42, Jalan Merbau Pulas, Kawasan Perindustrian Kuala Ketil, 09300 Kuala Ketil, Baling, Kedah MALAYSIA Tel : +604-4161600 Fax : +604-4161599 Website : www.southerncable.cc Email : [email protected]ISO9001 : 2008 Reg. No. : AR1757
45
Embed
KL Office - Deltricdeltric.com.my/pdf/006-telecommunication-cables.pdf · KL Office : No.9-1 & 9-2, Jalan Puteri 5/20, Bandar Puteri, 47100 Puchong, Selangor MALAYSIA Tel : +603-80601222,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
KL Office :No.9-1 & 9-2, Jalan Puteri 5/20, Bandar Puteri,47100 Puchong, Selangor MALAYSIATel : +603-80601222, +603-8061112, +80601100 Fax : +603-80601212Website : www.southerncable.ccEmail : [email protected]
Head Office & Factory :Lot 42, Jalan Merbau Pulas,Kawasan Perindustrian Kuala Ketil,09300 Kuala Ketil, Baling, KedahMALAYSIATel : +604-4161600 Fax : +604-4161599Website : www.southerncable.ccEmail : [email protected]
ISO9001 : 2008Reg. No. : AR1757
TYPES OF TELECOMMUNICATION CABLES
Cables Plastic Twin Pair, Triple and Unit Type Internal Telephone Cable
* For 1 Pair, 3 Wires, 2 Pairs - CCA conductor also available
http://www.southerncable.cc
TELEPHONE CABLE SOUTHERN CABLE
CABLES PLASTIC TWIN PAIR, TRIPLE AND UNIT TYPE INTERNAL TELEPHONE CABLE
Conductor Size
Insu
lati
on
Thic
kne
ss
She
ath
Th
ickn
ess
No
min
al D
iam
ete
r
Ap
pro
x. W
eigh
t
Stan
dar
d L
en
gth Resistance at 20oC
Insu
lati
on
Elo
nga
tio
n (
min
)
Mu
tual
Un
bal
ance
Cap
acit
an
ce
Un
bal
ance
Insu
lati
on
Res
ista
nce
Max
Ave
.
Max
99
% o
f
case
s
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Specification : TMB Spec. CI0001
Conductor : Annealed Copper Wire
Insulation : General Purpose PVC Compound
Sheathing : Grey Color Hard Grade PVC
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
CABLES PLASTIC TWIN PAIR, TRIPLE AND UNIT TYPE INTERNAL TELEPHONE CABLE
Pair No. A-Wire B-Wire
Insulation Color of Conductors
1 First 5 Pairs Unit
Notes
10 Pairs Unit
10
White
White
White
White
White
Red
Red
Red
Red
Red
2
3
4
5
6
3 Wires
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Orange
Orange
7
8
9
-
-
-
-
-
-
-
-
Second 5 Pairs Unit
White
White
1 Pair only
-
-
-
-
-
Green
-
-
-
-
-
-
-
Specification : TMB Lines CL0522
Conductor : Plain Annealed Copper Wire
Insulation : Cellular Polyethylene
Sheathing : Solid Polyethylene
Conductor : Annealed Copper Wire
Insulation : The insulation is a dual insulation with an inner core of cellular polyethylene
and an outer skin of solid PE
Twinning : Two insulated conductors twisted together to form a pair to ground
Stranding Unit : 25 Pairs
Laid-up : Units are laid up into a compact and symmetrical cable core
Core Wrapping : The cable core is wrapped with a layer of mylar tape
: An Aluminum tape with polymer coating is applied over the cable core and
then sheathed with black PE
Insulation
Resistance
SizeSheath
Thickness
mm mm kg/km m/drum Ω/km Ω/km nF/km nF/km pF/500m pF/km MΩ.km DCV DCV
0.4 3.1 7320 250
0.4 3.0 6130 250
0.4 2.9 4960 500
0.5 3.1 6630 250
0.5 3.0 5730 250
0.5 2.9 4810 500
0.5 2.8 3900 500
0.5 2.7 2970 500
0.5 2.3 2020 1000
0.5 2.1 1070 1000
0.5 2.0 585 1000
0.63 3.2 7500 250
0.63 3.0 6000 250
0.63 2.9 4580 500
0.63 2.7 3130 500
0.63 2.2 1620 1000
0.63 2.1 870 1000
0.9 2.7 3160 500
0.9 2.3 1640 1000
http://www.southerncable.cc
1000
800
600
48
35
26
48
28
21
73
3 %
of
Ave
rage
Val
ue
63
58
52
46
66
58
2400
2000
1600
1400
400
200
100
800
600
200
100
200
100
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided
in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
35
600 4000
PE Cable
Overall
Dia.
52 ± 2 200 574 10000
52 ± 2 200 574 10000 4000
Dielectric
Strength
Co
nd
. to
Co
nd
.
Co
nd
.to
Shie
ld
Mutual
Capacitance
Max
.
Max
. Ave
.Capacitance
Unbalance
Pai
r to
Pai
r
Pai
r to
Gn
d
MinNo. of
Pairs
Approx.
Weight
Packing
Length
Max
.
Ave
rage
Max
. fo
r 9
0%
of
case
s
Conductor
Resistance
1200
1000
Pr.
143 150
91 96
mm
69
64
58
68
38
TELEPHONE CABLE SOUTHERN CABLE
POLYETHYLENE INSULATED , 25 PAIRS UNIT TWIN,
MOISTURE BARRIER SHEATHED TELEPHONE CABLE ( PEUT FS)
Moisture Barrier Sheath
58 60
200 574 10000 600 4000
10000 600 4000
28 30 52 ± 2
52 ± 2 200 574
400
600
DIMENSIONAL AND ELECTRICAL CHARACTERISTIC
Conductor
Specification : TMB Lines CL0522
Conductor : Plain Annealed Copper Wire
Insulation : Cellular Polyethylene
Sheathing : Solid Polyethylene
Conductor : Annealed Copper Wire
Insulation : The insulation is a dual insulation with an inner core of cellular polyethylene
and an outer skin of solid PE
Twinning : Two insulated conductors twisted together to form a pair
Stranding Unit : 25 Pairs
Laid-up : Units are laid up into a compact and symmetrical cable core
Core Wrapping : The cable core is wrapped with a layer of mylar tape
: An Aluminum tape with polymer coating is applied over the cable core and
then sheathed with black PE
25
Pai
r G
rou
p
Nu
mb
er
25
Pai
r G
rou
p
Nu
mb
er
Gro
up
Pai
r C
ou
nt
25
Pai
r G
rou
p
Nu
mb
er
Gro
up
Pai
r C
ou
nt
25
Pai
r G
rou
p
Nu
mb
er
Gro
up
Pai
r C
ou
nt
1 8 176-200 15 351-375 22 526-550 Violet-Orange
2 9 200-225 16 376-400 23 551-575 Violet-Green
3 10 226-250 17 401-425 24 576-600 Violet-Brown
4 11 251-275 18 426-450 25 576-600 Violet-Grey
5 12 276-300 19 451-475
6 13 301-325 20 476-500
7 14 326-350 21 501-525
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided
in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
151-175
White-Blue
White-Orange
White-Green
White-Brown
White-Grey
Red-Blue
Red-Orange
Co
lor
of
Gro
up
Ide
nti
fica
tio
n
Gro
up
Pai
r C
ou
nt
1-25
26-50
51-75
76-100
101-125
126-150
COLOR IDENTIFICATION
Moisture Barrier Sheath
Black-Grey
Yellow-Blue
Yellow-Orange
Yellow-Green
Yellow-Brown
Yellow-Green
POLYETHYLENE INSULATED , 25 PAIRS UNIT TWIN,
MOISTURE BARRIER SHEATHED TELEPHONE CABLE ( PEUT FS)
TELEPHONE CABLE SOUTHERN CABLE
Violet-Blue
Red-Green
Red-Brown
Red-Grey
Black-Blue
Black-Orange
Black-Green
Black-BrownC
olo
r o
f G
rou
p
Ide
nti
fica
tio
n
Co
lor
of
Gro
up
Ide
nti
fica
tio
n
Co
lor
of
Gro
up
Ide
nti
fica
tio
n
Specification : TMB Lines CL0522
Conductor : Plain Annealed Copper Wire
Insulation : Cellular Polyethylene
Sheathing : Solid Polyethylene
Conductor : Annealed Copper Wire
Insulation : The insulation is a dual insulation with an inner core of cellular polyethylene
and an outer skin of solid PE
Twinning : Two insulated conductors twisted together to form a pair to ground
Stranding Unit : 25 Pairs
Laid-up : Units are laid up into a compact and symmetrical cable core
Core Wrapping : The cable core is wrapped with a layer of mylar tape
: An Aluminum tape with polymer coating is applied over the cable core and
then sheathed with black PE
1 1-25 White-Blue 13 301-325 Black-Green 1st 24 groups 1-600 White
2 26-50 White-Orange 14 326-350 Black-Brown 2nd 24 groups 601-1200 Red
3 51-75 White-Green 15 351-375 Black-Grey 3rd 24 groups 1201-1800 Black
MOISTURE BARRIER SHEATHED TELEPHONE CABLE ( PEUT FS)
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Moisture Barrier Sheath
Binder Tape For Cable Up To 600 Pairs Binder Tape for Cable More than 600 pairs
Note : Associated groups of 12 pairs and 13 pairs shall have identical colored tape lappings
The color scheme is applicable to multiple units of 50 or
100 pair group within the 24 groups (of 25 pair units)
Conductor : Annealed Copper WireInsulation : 3 Colored foam skin PolyolefinTwinning : Two insulated conductors twisted together to form a pairStranding Unit : 5 or 10 pairsLaid-up : Units are laid up into a compact and symmetrical cable coreCore Wrapping : The cable core is wrapped with a layer of mylar tapeFiller : The interstices of the cable core are completely filled with jelly compound
: An Aluminum tape with polymer coating is applied over the cable core and then sheathed with black PE
Insulation
Resistance
SizeSheath
Thickness
mm mm kg/km m/drum Ω/km Ω/km nF/km nF/km pF/500m pF/km MΩ.km DCV DCV
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
20 11.9
50
100
200 76.9
56.0
20 27.6
30 32.7
40.7
15.7
18.5
10
20
10 21.1
10 14.8
20 19.2
30 21.3
50 27.1
100 38.1
200 51.0
30 13.2
50 15.3
13.7
19.3
26.5
11.5
13.9
15.3
18.3
23.8
100
200
10
32.4
50 22.0
100 28.7
20
30
50
100
200
30
mm
10 10.2
Capacitance
Unbalance
Dielectric
Strength
Max
.
Ave
rage
Max
. fo
r
90
% o
f
case
s
Max
.
Ave
.
Max
.
Pai
r to
Pai
r
Pai
r to
Gn
d
Min
.
Co
nd
. to
Co
nd
.
3 %
of
Ave
rage
Val
ue
200 39.4
TELEPHONE CABLE SOUTHERN CABLE
FULLY FILLED, UNIT TWIN, MOISTURE BARRIER SHEATH CABLE FOR
Length less than 100 meters are considered as 100 meters.The measured values shall be divided by ½ (L/500 + √(L/500)) where L is the length in meter of the cable under test.
Conductor PE CableApprox.
Weight
Packing
Length
Conductor
Resistance
Mutual
Capacitance
Co
nd
. to
Shie
ld
No. of
Pairs
Overall
Dia.
Pr.
1 White Blue 1 11 Blue
2 White Orange 1A,1B
3 White Green 2 12 Orange
4 White Brown 2A,2B
5 White Grey 3 Green 13 Green
6 Red Blue 4 Brown 14 Brown
7 Red Orange 5 Grey 15 Grey
8 Red Green 6 Blue-White 16 Blue-White
9 Red Brown 7 Orange-White 17 Orange-White
10 Red Grey 8 Green-White 18 Green-White
9 Brown-White 19 Brown-White
10 Grey-White 20 Grey-White
Unit No. 11 -20 only apply to 200 Pair cable
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
FULLY FILLED, UNIT TWIN, MOISTURE BARRIER SHEATH CABLE FOR
Unit No. Color of Binder Unit No. Pair No. A-Wire B-Wire
Specification : TMB LINES AC0001
Conductor : PLAIN ANNEALED COPPER WIRE
Insulation : HIGH DENSITY POLYETHYLENE
Sheathing : POLYETHYLENE
Conductor : Annealed Copper WireInsulation : High density Polyethylene conforming with the color standard of BS6746CTwinning : Two insulated conductors twisted together to form a pairStranding Unit : 5 or 10 pairsLaid-up : Units are laid up into a compact and symmetrical cable coreCore Wrapping : The cable core is wrapped with a layer of mylar tapeBearer Wire : High tensile galvanized steel wireMoisture Barrier Sheath : An Aluminum tape with polymer coating is applied over the cable core and then sheathed with black PE
UNIT TWIN TYPE, INTEGRAL BEARER FOR AERIAL ERECTION (PEUT IB)
http://www.southerncable.cc
7/2.0
5
30 7/1.2
50 7/1.2
100
5
200 7/2.0
20
30
1/2.5
DimensionApprox.
Weight
7/1.2
7/1.6
7/1.2
7/2.0
10 1/2.5
7/1.2
7/1.6
7/2.0
5 1/2.5
50 1/2.5
Packing
Length
10
20 7/1.2
30 7/1.2
50
1/2.5
10 1/2.5
7/1.6
100
200
1/2.5
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
The measured values shall be divided by ½ (L/500 + √(L/500)) where L is the length in meter of the cable under test.
Length less than 100 meters are considered as 100 meters.
20 1/2.5
7/2.0
100 7/1.6
400
100
400
10
50 7/1.2
200 7/1.6
7/2.0
5 1/2.5
30
20 1/2.5
Conductor Bearer Wire
5 1/2.5
1/2.5
No. of Pairs
Pr. mm
Size
10 1/2.5
20 1/2.5
30
Electrical Characteristics
Insulation
Resistance
Max. Ave. Max.Pair to
PairPair to Gnd Min
Conductor to
Conductor
Conductor
to Shield
mm nF/km nF/km pF/500m pF/km MΩ.km DCV DCV
0.40 52 ± 2 200 574 10,000 2000 4000
0.50 52 ± 2 200 574 10,000 2000 4000
0.63 52 ± 2 200 574 10,000 2000 4000
0.90 52 ± 2 200 574 10,000 2000 4000
1.27 52 ± 2 200 574 10,000 2000 4000
Unit No.Color of
BinderUnit No.
Color of
Binder
1 Blue 11 Blue
1 1A,1B
2 2 Orange 12 Orange
3 2A,2B
4 3 Green 13 Green
5 4 Brown 14 Brown
6 5 Grey 15 Grey
7 6 Blue-White 16 Blue-White
8 7 Orange-White 17 Orange-White
9 8 Green-White 18 Green-White
10 9 Brown-White 19 Brown-White
1st 5 pair is from No.1 to No. 5 10 Grey-White 20 Grey-White
2nd 5 pair is from No. 6 to No. 10 Unit No. 11 -20 only apply to 200 Pair cable
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided
in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
White
Red
Red
Max. Average
Ω/km
143
91
58
28
14 15
30
60
96
150
Ω/km
Color Scheme for 5-Pair and 10-Pair Units Color of Binder Tapes 10 Pair Units
The measured values shall be divided by ½ (L/500 + √(L/500)) where L is the length in meter of the cable under test. Length less than 100 meters are considered
Note : For screened cables, the maximum overall diameters may be increased by 1.5 mm
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
No. pr. X lbs mm mm mm mm mm X mm Ω/km % kg/km kg/km m/coil
4 1 X 10 0.630 1.0 1.2 1.0 6.92 X 5.91 58.1 25 45 33 250
5 1 X 20 0.900 1.0 1.2 1.0 7.55 X 6.50 28.5 25 53 41 250
KTMB 1 X 25 1.020 1.0 1.2 1.0 7.67 X 6.74 24 25 56 44 500
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
SELF - SUPPORTING DROP WIRE
Cable Type
Conductor Steel Wire
Ove
rall
Dim
en
sio
n
Approx. Weight
Packing
Length
Min
. elo
nga
tio
n
Max
. Re
sist
ance
TELEPHONE CABLE SOUTHERN CABLE
CHARACTERISTIC
No. of Conductor Insulation
Pair Number / Resistance Resistance
Wire Dia. (Max) (Min)
No. / mm - mm - mm - Ω (20ºC) M Ω - Km
3 1 / 0.40 Tinned Cu. 0.85 PVC 4.6 PVC 157 100
4 1 / 0.40 Tinned Cu. 0.85 PVC 4.8 PVC 157 100
8 1 / 0.40 Tinned Cu. 0.85 PVC 5.3 PVC 157 100
10 1 / 0.40 Tinned Cu. 0.85 PVC 7.0 PVC 157 100
12 1 / 0.40 Tinned Cu. 0.85 PVC 7.2 PVC 157 100
15 1 / 0.40 Tinned Cu. 0.85 PVC 8.2 PVC 157 100
16 1 / 0.40 Tinned Cu. 0.85 PVC 8.3 PVC 157 100
24 1 / 0.40 Tinned Cu. 0.85 PVC 9.6 PVC 157 100
25 1 / 0.40 Tinned Cu. 0.85 PVC 9.7 PVC 157 100
30 1 / 0.40 Tinned Cu. 0.85 PVC 10.2 PVC 157 100
32 1 / 0.40 Tinned Cu. 0.85 PVC 10.5 PVC 157 100
40 1 / 0.40 Tinned Cu. 0.85 PVC 11.6 PVC 157 100
48 1 / 0.40 Tinned Cu. 0.85 PVC 11.8 PVC 157 100
CHARACTERISTIC
No. of Conductor Insulation
Pair Number / Resistance Resistance
Wire Dia. (Max) (Min)
No. / mm - mm - mm - Ω (20ºC) M Ω - Km
3 1 / 0.50 Tinned Cu. 0.96 PVC 4.9 PVC 97.8 100
4 1 / 0.50 Tinned Cu. 0.96 PVC 5.3 PVC 97.8 100
8 1 / 0.50 Tinned Cu. 0.96 PVC 6.9 PVC 97.8 100
10 1 / 0.50 Tinned Cu. 0.96 PVC 7.5 PVC 97.8 100
12 1 / 0.50 Tinned Cu. 0.96 PVC 8.0 PVC 97.8 100
15 1 / 0.50 Tinned Cu. 0.96 PVC 8.8 PVC 97.8 100
16 1 / 0.50 Tinned Cu. 0.96 PVC 9.0 PVC 97.8 100
24 1 / 0.50 Tinned Cu. 0.96 PVC 10.6 PVC 97.8 100
25 1 / 0.50 Tinned Cu. 0.96 PVC 10.8 PVC 97.8 100
30 1 / 0.50 Tinned Cu. 0.96 PVC 11.7 PVC 97.8 100
32 1 / 0.50 Tinned Cu. 0.96 PVC 12.0 PVC 97.8 100
40 1 / 0.50 Tinned Cu. 0.96 PVC 13.2 PVC 97.8 100
48 1 / 0.50 Tinned Cu. 0.96 PVC 14.3 PVC 97.8 100
http://www.southerncable.cc
PVC/PVC SWITCHBOARD CABLE (VF CABLE 600Ω ) SWVP
Dia. Material
CONSTRUCTION
CONDUCTOR INSULATION
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Material
Material Material Dia.
Material Material
JACKET
Dia. Dia.
CONSTRUCTION
CONDUCTOR INSULATION JACKET
INS. SHIELDED
Nu
mb
er/
Wir
e
Dia
me
ter
Mat
eri
al
Dia
me
ter
Mat
eri
al
Mat
eri
al
Nu
mb
er/
Wir
e
Dia
me
ter
Mat
eri
al
Dia
me
ter
Mat
eri
al
No. / mm - mm - - No. / mm - mm - Ω (20ºC) M Ω - Km
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the
suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or
explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
PVC/PVC SWITCHBOARD CABLE (VF CABLE 600Ω ) SWVSA
No.
of
Pair
Co
nd
uct
or
Re
sist
ance
(min
)
No.
of
Pair
CONSTRUCTION
CONDUCTOR DRAIN WIRE JACKET
Co
nd
uct
or
Re
sist
ance
(max
)
CHARACTERISTIC
Co
nd
uct
or
Re
sist
ance
(max
)
CHARACTERISTICCONSTRUCTION
CONDUCTOR INS. DRAIN WIRE JACKET
Co
nd
uct
or
Re
sist
ance
(min
)
No. of Identification IdentificationPair Marking Marking
1 Light Blue - Red Black 25 Light Grey - - - - - - (Cont) Red Black
2 Light Pink - Red Black 26 Light Blue - Red Black
3 Light Green - Red Black 27 Light Pink - Red Black
4 Light Orange - Red Black 28 Light Green - Red Black
5 Light Grey - Red Black 29 Light Orange - Red Black
6 Light Blue -- Red Black 30 Light Grey - Red Black
7 Light Pink -- Red Black 31 Light Blue -- Red Black
8 Light Green -- Red Black 32 Light Pink -- Red Black
9 Light Orange -- Red Black 33 Light Green -- Red Black
10 Light Grey -- Red Black 34 Light Orange -- Red Black
11 Light Blue --- Red Black 35 Light Grey -- Red Black
12 Light Pink --- Red Black 36 Light Blue --- Red Black
13 Light Green --- Red Black 37 Light Pink --- Red Black
14 Light Orange --- Red Black 38 Light Green --- Red Black
15 Light Grey --- Red Black 39 Light Orange --- Red Black
16 Light Blue ---- Red Black 40 Light Grey --- Red Black
17 Light Pink ---- Red Black 41 Light Blue ---- Red Black
18 Light Green ---- Red Black 42 Light Pink ---- Red Black
19 Light Orange ---- Red Black 43 Light Green ---- Red Black
20 Light Grey ---- Red Black 44 Light Orange ---- Red Black
21 Light Blue - - - - - - (Cont) Red Black 45 Light Grey ---- Red Black
22 Light Pink - - - - - - (Cont) Red Black 46 Light Blue ______(Cont)_______ Red Black
23 Light Green - - - - - - (Cont) Red Black 47 Light Pink ______(Cont)_______ Red Black
24 Light Orange - - - - - - (Cont) Red Black 48 Light Green ______(Cont)_______ Red Black
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
PVC/PVC SWITCHBOARD CABLE (VF CABLE 600Ω ) SWVSA
ColourMarking Colour
Pair No. ColourMarking Colour
1st Core 2nd Core 1st Core 2nd Core
TELEPHONE CABLE SOUTHERN CABLE
SHIELDED Conductor Insulation
Number / Resistance Resistance
Wire Dia. (Max) (Min)
No. / mm - mm - - mm - Ω (20ºC) M Ω - Km
Table 1 Table 2
A Wire B wire
1 White Blue
2 White Orange
3 White Green
4 White Brown
5 White Grey
6 White Blue
7 White Orange
8 White Green
http://www.southerncable.cc
97.8 500
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the
suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit
contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
No. A Wire B Wire No. A Wire B Wire No. A Wire B Wire
1 White Blue 1 White Blue 1 Blue White
2 White Orange 2 White Orange 2 Yellow White
3 White Green 3 White Green 3 Brown White
4 White Brown 4 White Brown 4 Black White
5 Red Blue 5 White Grey 5 Green White
6 Red Orange 6 Red Orange 6 Orange White
7 Red Green 7 Red Green 7 Grey White
8 Red Brown 8 Red Brown 8 Voilet White
Spare Pair Black Blue 9 Red Brown Spare Blue White
10 Red Grey Pair Yellow White
Table 2 11 Black Blue
Core Colour 12 Black Orange Table 2
1 13 Black Green
2 14 Black Brown
3 15 Black Grey 1
4 16 Yellow Blue 2
17 Yellow Orange 3
18 Yellow Green 4
19 Yellow Brown
20 Yellow Grey
21 Voilet Blue
22 Voilet Orange
23 Voilet Green
24 Voilet Brown
Table 2
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
VF SCREENED & SHIELDED CABLE (SWEBT)
Core Colour PTP Tape Colour Code
Blue
Orange
Green
Brown
1
2
3
4
33 PAIRS
Core ColourBlue
PTP Tape Colour Code
Yellow
Brown
Orange
WhiteGreen
Brown Blue
128 Pairs + 2P
Colour Code Colour of Insulation Colour of Insulation
PTP Tape Colour Code
50001 / 0.40 0.78 PVC
0.4mm •128P + 2P Bare Ann. Cu HDPE1 / 0.40 0.73+ Tinned Cu.
Braiding18.60 153 5000PVC
0.4mm •96P Bare Ann. Cu HDPE 17.10 153
CHARACTERISTIC
Type
11.00 1530.4mm •33P + G + 1P Bare Ann. Cu HDPE1 / 0.40 0.8 PVC 5000
Colour Chart of Insulation Colour Chart of Binder Tape
Pair
No. A Wire B Wire
1 White Blue
2 White Orange
3 White Green
4 White Brown
5 Red Grey
6 Red Blue
7 Red Orange
8 Red Green
9 Red Brown
10 Red Grey
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Colour Chart of Insulation Colour Chart of Binder Tape
No. of Binder Colour
A Wire B Wire B Wire Sub Unit
1 White Blue 14 Brown 1
2 White Orange 15 Grey 2
3 White Green 16 Blue 3
4 White Brown 17 Orange 4
5 Red Grey 18 Green 5
6 Red Blue 19 Brown
7 Red Orange 20 Grey
8 Red Green 21 Blue
9 Red Brown 22 Orange
10 Red Grey 23 Green
11 Black Blue 24 Brown
12 Black Orange 25 Grey
13 Black Green
http://www.southerncable.cc
Yellow
Voilet
Voilet
Voilet
Black
Yellow
TELEPHONE CABLE SOUTHERN CABLE
STP INDIVIDUAL PAIR SCREENED CABLE 120Ω (IVFESA)
Insulation Colour
A Wire
Black
Dia. Material
Pair
No.
Insulation ColourPair No.
Material Material Material
Dia. Material Material
SCREENED CONSTRUCTION CHARACTERISTIC
DRAIN WIREINSULATION
CONDUCTOR
SCREENED CONSTRUCTION CHARACTERISTIC
DRAIN WIRE JACKETINSULATION
CONDUCTOR
Dia. Material
JACKET
Dia.Material
Material Material
Blue
Orange
Green
Brown
Grey
Yellow
Voilet
Voilet
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Yellow
Yellow
Drain Wire
Polyester Yarn
PVC Sheathed
Polyester Yarn
PVC Sheathed
http://www.southerncable.cc
Mylar Tape
Mylar Tape
Al / Mylar
Drain Wire
Polyester Yarn
PVC Sheathed
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Al / Mylar
Drain Wire
Polyester Yarn
PVC Sheathed
Al / Mylar
Mylar Tape
Drain Wire
Mylar Tape
Al / Mylar
STP INDIVIDUAL PAIR SCREENED CABLE 120Ω (IVFESA)
TELEPHONE CABLE SOUTHERN CABLE
2
1
Pair 4 Pair 1
Pair 3 Pair 2
Pair 2
Pair 1
Pair 6
Pair 4
Pair 3
Pair 8
Pair 5
Pair 7
Pair
Pair4
Pair11
Pair3
Pair5
Pair6
Pair7
Pair2
Pair9
Pair1
Pair10
Pair8
Pair 7
Pair 4
Pair10
Pair11
Pair12
Pair13
Pair 3
Pair15
Pair 9
Pair 2
Pair 6Pair 1
Pair14
Pair16
Pair 5
Pair 8
http://www.southerncable.cc
TELEPHONE CABLE SOUTHERN CABLE
STP INDIVIDUAL PAIR SCREENED CABLE 120Ω (IVFESA)
http://www.southerncable.cc
STP INDIVIDUAL PAIR SCREENED CABLE 120Ω (IVFESA)
TELEPHONE CABLE SOUTHERN CABLE
No. SCREENED DRAIN WIRE
of Number / Number /
Pair Wire Diameter Wire Dia.
No. / mm - mm - - mm mm -
2 1 / 0.26 Tinned Cu. 0.48 LDPE 2 Layer of Al / Mylar 0.26 2.62 PVC
4 1 / 0.26 Tinned Cu. 0.48 LDPE 2 Layer of Al / Mylar 0.26 3.13 PVC
8 1 / 0.26 Tinned Cu. 0.48 LDPE 2 Layer of Al / Mylar 0.26 3.84 PVC
12 1 / 0.26 Tinned Cu. 0.48 LDPE 2 Layer of Al / Mylar 0.26 5.29 PVC
25 1 / 0.26 Tinned Cu. 0.48 LDPE 2 Layer of Al / Mylar 0.26 6.63 PVC
2 1 / 0.40 Tinned Cu. 0.78 LDPE 2 Layer of Al / Mylar 0.40 4.48 PVC
4 1 / 0.40 Tinned Cu. 0.78 LDPE 2 Layer of Al / Mylar 0.40 5.33 PVC
8 1 / 0.40 Tinned Cu. 0.78 LDPE 2 Layer of Al / Mylar 0.40 6.59 PVC
12 1 / 0.40 Tinned Cu. 0.78 LDPE 2 Layer of Al / Mylar 0.40 7.53 PVC
25 1 / 0.40 Tinned Cu. 0.78 LDPE 2 Layer of Al / Mylar 0.40 9.66 PVC
CHARACTERISTIC
No. Characteristic Conductor Insulation
of Impedance Resistance Resistance
Pair (Max) (Min)
Ω Ω (20ºC)
2 110 382
4 110 382
8 110 382
12 110 382
25 110 382
2 110 157
4 110 157
8 110 157
12 110 157
25 110 157
1. Tin Ann. Cu
2. PE Insulation
3. Mylar Tape
4. Tinned Drain Wire
5. Al/PS Tape (2 layers)
6. Polyester Yarn
7. PVC Sheathed
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
AC BUS CABLE (DOUBLE SCREENING)
TELEPHONE CABLE SOUTHERN CABLE
Dia. Material Material
CONDUCTOR
Material
M Ω - Km
5000
5000
5000
5000
SCREENED CONSTRUCTION
INSULATION
Material Dia.
JACKET
5000
500
500
500
500
500
7
1
3
8
54
3
21
7
2
6
4
5
6
710
6
9
8
1
12
4
5
1
23
Marking
Identifcation 1st Core 2nd Core
1 Light Blue - Red Black
2 Light Pink - Red Black
3 Light Green - Red Black
4 Light Orange - Red Black
5 Light Grey - Red Black
6 Light Blue -- Red Black
7 Light Pink -- Red Black
8 Light Green -- Red Black
9 Light Orange -- Red Black
10 Light Grey -- Red Black
11 Light Blue --- Red Black
12 Light Pink --- Red Black
13 Light Green --- Red Black
14 Light Orange --- Red Black
15 Light Grey --- Red Black
16 Light Blue ---- Red Black
17 Light Pink ---- Red Black
18 Light Green ---- Red Black
19 Light Orange ---- Red Black
20 Light Grey ---- Red Black
21 Light Blue ------ (Cond) Red Black
22 Light Pink ------ (Cond) Red Black
23 Light Green ------ (Cond) Red Black
24 Light Orange ------ (Cond) Red Black
25 Light Grey ------ (Cond) Red Black
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Pair No. ColourMarking Colour
TELEPHONE CABLE SOUTHERN CABLE
AC BUS CABLE (DOUBLE SCREENING)
No. SCREENED DRAIN WIRE
of Number / Number /
Pair Wire Diameter Wire Diameter
No. / mm - mm - - mm mm -
1 7 / 0.20 Tinned Cu. 1.30 HDPE Opp / Al Foil 7 / 0.20 4.51 PVC
2 7 / 0.20 Tinned Cu. 1.30 HDPE Opp / Al Foil 7 / 0.20 7.11 PVC
4 7 / 0.20 Tinned Cu. 1.30 HDPE Opp / Al Foil 7 / 0.20 8.59 PVC
6 7 / 0.20 Tinned Cu. 1.30 HDPE Opp / Al Foil 7 / 0.20 11.91 PVC
12 7 / 0.20 Tinned Cu. 1.30 HDPE Opp / Al Foil 7 / 0.20 17.92 PVC
No. Conductor Insulation 1st Wire 2nd Wire
of Resistance Resistance 1 White Blue
Pair (Max) (Min) 2 White Orange
KV AC Ω (20ºC) M Ω - Km 3 White Green
1 1 2 83.2 1000 4 White Brown
2 2 2 83.2 1000 5 White Grey
3 4 2 83.2 1000 6 Red Blue
4 6 2 83.2 1000 7 Red Orange
5 12 2 83.2 1000 8 Red Green
9 Red Brown
10 Red Grey
11 Black Blue
12 Black Orange
Arrow
1 - Mylar Tape
2 - Drain Wire
3 - OPP/Al foil
1 Insulated Pairs 4 - Polyester Yarn
5 - PVC Jacket
http://www.southerncable.cc
2 Insulated Pairs 4 Insulated Pairs
TELEPHONE CABLE SOUTHERN CABLE
DATA SPEED CABLE OVERALL SCREENED (AWM)
Material
No.
CHARACTERISTIC
Spark Test
Diameter Material Material
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Pair No.Insulation Colour
CONDUCTOR
SCREENED CONSTRUCTION
JACKETINSULATION
Material Diameter
2
3
4
5
1
1
2
3
4
5
1
2
11
4 2
3
2
3
4
5
1
Arrow
1 - Mylar Tape
2 - Drain Wire
3 - OPP/Al foil
4 - Polyester Yarn
5 - PVC Jacket
http://www.southerncable.cc
TELEPHONE CABLE SOUTHERN CABLE
DATA SPEED CABLE OVERALL SCREENED (AWM)
6 Insulated Pairs
12 Insulated Pairs
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
3
1 2
87
9
10
11
12
4
6
5
2
3
4
5
1
4
F
3
5
6
1
2
2
3
4
5
1
Conductor Insulation
Res. At 20ºC Res. At 20ºC
Max : Ω-Km Max : MΩ-Km
Ω (20ºC) M Ω - Km
UTP 97.8 100
Tinned Copper Insulation Overall Approx. PackingNo. Diameter Colour Insulation Thickness Dia Weight LengthPair Nom. (mm) Identification Material
Max : ( Ω )
CJV 91.40
Colour Insulation
Identification Material
Nom. (mm) Nom. (mm) Kg / km m / Coil
1 wire 0.50 0.505 White PVC 0.20 1.0 2.5 250
White / Blue or
White / Green
3 wires 0.50 0.505 White / Green / Red PVC 0.20 2.2 7.7 250
White / Green /
Red / Blue
White / Green /
Red / Blue / Grey
http://www.southerncable.cc
250
250
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in
the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
JUMPER WIRE (2Mb/S)
Overall DiaApprox.
Weight
Packing
Length
250
5 wires 0.50 0.505 0.20 12.8
4 wires
(Quad)0.50 0.505 0.20
12.8
No. wires /
Pairs Max. (mm)Nom. (mm)
250
1 Pair 0.50 0.505 0.20PVC
1 Pair 0.510 0.520 Dark Grey / Red PE
Max. (mm)Nom. (mm) Kg / km
4.74
Tinned Copper Diameter Insulation
Thickness
Malaysia TMB SPEC. LINES A 1000
Resistance Per km A + 20ºC
Nom : ( Ω )
89.55
m / Coil
0.21 1.86
Nom. (mm)
2.0 5.1
10.2PVC
PVC
10.2
Conductor : Annealed Copper WireInsulation : The insulation is a dual insulation with an inner core of cellular
polyethelene and an outer skin of solid polyetheleneTwinning : Two insulated conductors twisted together to form a pairStanding Unit : 25 pairsLaid-up : Units are laid-up into a compact and symmetrical cable coreCore Wrapping : The cable core is wrapped with a layer of mylar tapeMoisture Barrier Sheath : An aluminum tape with polymer coating is applied over the cable
core and then sheathed with black polyethelene
ELECTRICAL CHARACTERISTIC
Insulation
Resistance
Max
Average
Max for 90%
of cases
Max
AverageMax.
*Pair to
Pair
*Pair
to PairMin.
conductor
to
conductor
conductor
to shield
mm ohm/km ohm/km nF/km nF/km pF/500m pF/km M.ohm/km DCV DCV
1.27 14 15 52 ± 2 " 200 574 10,000 600 4000* The measured values shall be divided 1/2 (L/500+√L/500) where L is the length in meter of the cable under test.
Length less than 100 meters ore considered as 100 meters.
CONSTRUCTION DATA COLOR SCHEME FOR PAIRS WITHIN 25 PAIRS UNIT
PE Cable
sizeNo. of
pairs
Sheath
Thickness
Overall
Dia.A-Wire B-Wire A-Wire B-Wire
mm pr mm mm kg/km m/drum 1 white blue 14 black brown
0.40 2400 3.1 69 7320 250 2 white orange 15 black grey
0.40 2000 3.0 64 6130 250 3 white green 16 yellow blue
0.40 1600 2.9 58 4960 500 4 white brown 17 yellow orange
0.50 1400 3.1 68 6630 250 5 white grey 18 yellow green
0.50 1200 3.0 63 5730 250 6 red blue 19 yellow brown
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
http://www.southerncable.cc
Pair
No.
ConductorApprox.
Weight
Packing
Length
Pair
Number
Color of Conductor
Insulation
Size
Conductor Resistance
at 20°C
Mutual
Capacitance
Capacitance
UnbalanceDielectric Strength
Conductor : Annealed Copper WireInsulation : The insulation is a dual insulation with an inner core of cellular
polyethelene and an outer skin of solid polyetheleneTwinning : Two insulated conductors twisted together to form a pairStanding Unit : 25 pairsLaid-up : Units are laid-up into a compact and symmetrical cable coreCore Wrapping : The cable core is wrapped with a layer of mylar tapeMoisture Barrier Sheath : An aluminum tape with polymer coating is applied over the cable
core and then sheathed with black polyethelene
BINDER TAPE FOR CABLE UP TO 600 PAIRS
13
14
15
16
17
18
19
20
21
22
23
24
Note : Associated groups of 12 pairs and 13pairs shall have identical colored tape lapping
Note : The color scheme is applicable to multiple units of 50 or 100 pair group within the 24 groups (of 25 pair units)
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should
independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only
provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
2,400 Pairs
H11
H19
H3
H4
H5H6
H7
H8
H2
H1
H9
H10
H12
H13
H14H15
H16
H17
H18
H20
H1
H2H3
H4
H5
H6
H7H8
H9
H10
H11
H12
H13
H14
H15
H16
H17H18
H19
H20
H21
H22
H23
H24
CONSTRUCTION DATA
PE
Thickness Depthmm pr mm mm mm mm mm mm mm kg/km kg/km0.40 5 2.1 1/2.5 2.0 1.5 1.0 14.9 8.6 125 2000
COLOR OF BINDER TAPES 10 PAIR UNITS COLOR SCHEME FOR 5 PAIR&10 PAIR UNITS
1 11 A-Wire B-Wire(1A, 1B) 1 white blue
2 12 2 white orange
(2A,2B) 3 white green
3 13 4 white brown
4 14 5 white grey
5 15 6 red blue
6 16 7 red orange
7 17 8 red green
8 18 9 red brown
9 19 10 red grey
10 20 NOTE :1st 5 pair is from no.1 to no.5
NOTE: Units No.11-20 only apply to 200 pairs only 2nd 5 pair is from no.6 to no.10
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
UNIT TWIN TYPE, INTEGRAL BEARER FOR AERIAL ERACTION (PEUT IB)
MALAYSIA TMB SPEC. AC 0001
Bearer Sheath
Thickness
Dimension
M2M1Approx.
Weight
Conductor
Size No. of
Pairs
Sheath
Thickness
Bearer Wire
SizeWeb
Unit No.
blue
Packing
Length
Pair
Number
Color of Conductor
Insulationblue
CROSS-SECTION OF PEUTIB CABLE
CABLE MAKE-UP
- 4 X 5 Pair Sub Units
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
UNIT TWIN TYPE, INTEGRAL BEARER FOR AERIAL ERACTION (PEUT IB)
5 Pairs Cable
(or Sub Unit)
10 Pairs Cable
(or Sub Unit)
20 Pairs Cable
(or 20 Pair Unit)
30 Pairs Cable
- 3 X 10 Pair Sub Units
100 Pairs Cable
- Core 1 X 20 Pair Units
- Layer 8 X 10 Pair Sub Units
50 Pairs Cable
- 5 X 10 Pair Sub Units
M2
M1
Bearer Wire
PE Web
Cable Core
Aluminum Foil
PE Sheath
35
2
4
1
1B
2A 2B
1A4
6
10
82
59
3
7
1 13
2
1
2
34
5
2A
1A 1B
2B
3
4
5
67
8
9
10
CABLE MAKE-UP
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
UNIT TWIN TYPE, INTEGRAL BEARER FOR AERIAL ERACTION (PEUT IB)
400 Pairs Cable
- Core 100 Pairs Unit
- Layer 6 X 50 Pair Units
200 Pairs Cable
- Core 100 Pairs Unit
- Layer 10 X 10 Pair Sub Units
7 6
1A 1B
2B2A
3
4
58
9
10
11
12
13
14
1516
17
18
19
20
2
3
45
6
7
1
CABLE DIMENSIONS FOR 0.4MM CONDUCTORS
5
10
20
30
50
75
100
CABLE DIMENSIONS FOR 0.5MM CONDUCTORS
2
5
10
20
30
50
75
100
CABLE DIMENSIONS FOR 0.63MM CONDUCTORS
2
5
10
20
30
50
75
100
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
1.5 27.5 2.0 1.2 35.5
NOTE : For screened cables, the maximum overall diameters may be increased by 1.5mm
1.3 16.5 1.6 1.0 23.0
1.4 24.5 1.6 1.1 31.5
1.4 20.5 1.6 1.1 27.5
1.2 11.5 0.9 0.9 17.0
1.2 14.0 1.25 0.9 20.0
1.1 8.0 0.9 0.9 13.5
1.1 9.5 0.9 0.9 15.0
Maximum
mm mm mm mm mm
No. of
Pairs
Thickness of SheathOverall Diameter of
Unarmoured Cable
Diameter of
Armoured Wire
Thickness of Outer
Protection
Overall Diameter of
Cable
Minimum Maximum Nominal Minimum
1.4 22.0 1.6 1.1 29.0
NOTE : For screened cables, the maximum overall diameters may be increased by 1.5mm
1.2 14.0 1.25 0.9 20.0
1.3 19.0 1.6 1.0 26.0
1.3 16.5 1.6 1.0 23.5
1.1 9.5 0.9 0.9 15.0
1.2 12.0 0.9 0.9 17.5
1.1 7.5 0.9 0.9 13.0
1.1 8.0 0.9 0.9 13.5
Maximummm mm mm mm mm
No. of
Pairs
Thickness of SheathOverall Diameter of
Unarmoured Cable
Diameter of
Armoured Wire
Thickness of Outer
Protection
Overall Diameter of
CableMinimum Maximum Nominal Minimum
1.3 18.5 1.6 1.0 25.5
NOTE : For screened cables, the maximum overall diameters may be increased by 1.5mm
FULLY FILLED, POLYETHLENE INSULATED, UNIT TWIN ARMOURED TELEPHONECABLE (BS 3573)
No. of
Pairs
Thickness of SheathOverall Diameter of
Unarmoured Cable
Diameter of
Armoured Wire
Thickness of Outer
Protection
Overall Diameter of
Cable
Minimum Maximum
1.3
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
1.7 36.0 2.0 1.4 44.5
NOTE : For screened cables, the maximum overall diameters may be increased by 1.5mm
41.01.6 32.5 2.0
4
68
10
Cable Core
35
2
4
1Steel Wire Armour (SWA)
PE or PVC Jacket
Cable Core
59
3
7
1
Steel Wire Armour (SWA)
PE or PVC Jacket
2
20 Pairs
30 Pairs
50 Pairs
http://www.southerncable.cc
TELEPHONE CABLE SOUTHERN CABLE
FULLY FILLED, POLYETHLENE INSULATED, UNIT TWIN ARMOURED TELEPHONECABLE (BS 3573)
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms
and conditions of sale.
Cable Core
1B
2
1A
2B Steel Wire Armour (SWA)
PE or PVC Jacket
Cable Core
1
2
3
Steel Wire Armour (SWA)
PE or PVC Jacket
Cable Core
2
4
5
3 Steel Wire Armour (SWA)
PE or PVC Jacket
1
Conductor : Annealed Copper Wire
Insulation : Black Polyethelene (or black PVC)
Suspension Wire : 1.2mm galvanized steel wire
Breaking Load : 128kg
Elongation : 3%
CONSTRUCTION DATA
DiameterInsulation
ThicknessDiameter
Insulation
ThicknessPVC PE
No. pr x lbs mm mm mm mm kg/mm kg/mm m/coil
4 1 x 10 0.63 1.0 1.2 1.0 455 33 250
5 1 x 20 0.90 1.0 1.2 1.0 53 41 250
KTMB Order 1 x 25 1.02 1.0 1.2 1.0 56 44 500
CONSTRUCTION DATA
No. pr x lbs mm ohm/km %
4 1 x 10 0.63 58.1 25
5 1 x 20 0.90 28.5 25
KTMB Order 1 x 25 1.02 24.0 25
CROSS - SECTION OF DROP WIRE
http://www.southerncable.cc
7.67 x 6.74
TELEPHONE CABLE SOUTHERN CABLE
SELF SOPPORTING DROP WIRE NO.4 & NO. 5
Cable TypeConductor Steel Wire
Overall Dimension
mm x mm
Appox. WeightPacking
Length
6.92 x 5.91
7.55 x 6.50
Cable TypeNominal
Diameter
max.
Resistance at
20°C
Min.
Elongation Specification
Telekom Lines OW 0004
issue 4
KTMB
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
DROP WIRE NO. 4
1.6R
1.2 D
0.5
2.88
0.25
0.63D1.315
0.4
0.4
4
IdentiicationMark
CROSS - SECTION OF DROP WIRE
DROP WIRE (0.63 mm X 1P)
DROP WIRE (0.90 mm X 1P)
http://www.southerncable.cc
TELEPHONE CABLE SOUTHERN CABLE
SELF SOPPORTING DROP WIRE NO.4 & NO. 5
DROP WIRE NO. 5
DROP WIRE (KTMB Order)
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
1.6R
1.2 D
0.5
3.2
0.3
0.9D1.45R
0.4
0.4
4
IdentiicationMark
3.20 mm
1.20 mm
1.5R
1.2 D
0.5
3.32
0.3
1.02D1.51R
0.4
0.4
4.56
IdentiicationMark
0.5 mm
1.0 mm
2.26 mm
3.20 mm
1.20 mm
0.5 mm
1.0 mm
3.24 mm
CROSS - SECTION OF DROP WIRE
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
TELEPHONE CABLE SOUTHERN CABLE
SELF SOPPORTING DROP WIRE NO.4 & NO. 5
DROP WIRE (0.63 mm X 2P)
0.5
0.3
1.0 mm
4.20m
3.20 mm
1.0 mm
Twisted Pair
Number /
Wire
Diameter
Material Thk Dia. Material Dia. Material
Conductor
Resistance
(Tinned Cu.)
mm² Formation No./mm - mm mm - mm - Max. ohm (20°C)
1 0.14 7/0.16 x 4C 7/0.16Tinned Cu. or
TCCA0.25 0.98 PVC 3.60 PVC 140
2 0.20 1/0.50 x 4C 1/0.50Tinned Cu. or
TCCA0.25 1.00 PVC 4.00 PVC 91
3 0.22 7/0.20 x 4C 7/0.20Tinned Cu. or
TCCA0.25 1.10 PVC 4.00 PVC 92
* TCCA : Tinned Copper Clad Aluminum
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
No.Size
Conductor Insulation Sheath Characteristic
TELEPHONE CABLE SOUTHERN CABLE
CABLE CONSTRUCTION
Conductor
Resistance
*(TCCA.)
Max. ohm (20°C)
196
128
129
PVC / PVC ALARM CABLE (CVS)
Conductor
PVC Insulation
PVC Sheathed
Number/
Wire Dia.Material Thk Dia. Material Material Coverage Dia. Material
mm² Formation No./mm - mm mm - - % mm -
1.1 0.22 7/0.20 x 2C 7/0.20 Tin Cu 0.35 1.30 PVC Tin Cu 95 4.58 PVC
1.2 0.22 7/0.20 x 4C 7/0.20 Tin Cu 0.35 1.30 PVC Tin Cu 95 5.40 PVC
1.3 0.22 7/0.20 x 8C 7/0.20 Tin Cu 0.35 1.30 PVC Tin Cu 95 6.66 PVC
1.4 0.22 7/0.20 x 12C 7/0.20 Tin Cu 0.35 1.30 PVC Tin Cu 95 7.98 PVC
1.5 0.22 7/0.20 x 24C 7/0.20 Tin Cu 0.35 1.30 PVC Tin Cu 95 10.66 PVC
2.1 0.50 16/0.20 x 2C 7/0.20 Tin Cu 0.65 2.22 PVC Tin Cu 95 6.73 PVC
2.2 0.50 16/0.20 x 4C 7/0.20 Tin Cu 0.65 2.22 PVC Tin Cu 95 7.78 PVC
2.3 0.50 16/0.20 x 8C 7/0.20 Tin Cu 0.65 2.22 PVC Tin Cu 95 9.90 PVC
2.4 0.50 16/0.20 x 12C 7/0.20 Tin Cu 0.65 2.22 PVC Tin Cu 95 11.64 PVC
2.5 0.50 16/0.20 x 24C 7/0.20 Tin Cu 0.65 2.22 PVC Tin Cu 95 11.94 PVC
3.1 0.75 24/0.20 x 2C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 7.38 PVC
3.2 0.75 24/0.20 x 3C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 7.76 PVC
3.3 0.75 24/0.20 x 4C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 8.63 PVC
3.4 0.75 24/0.20 x 6C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 10.05 PVC
3.5 0.75 24/0.20 x 8C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 11.09 PVC
3.6 0.75 24/0.20 x 10C 24/0.20 Tin Cu 0.65 2.43 PVC Tin Cu 95 12.78 PVC
4.1 1.00 32/0.20 x 2C 32/0.20 Tin Cu 0.65 2.61 PVC Tin Cu 95 7.77 PVC
4.2 1.00 32/0.20 x 3C 32/0.20 Tin Cu 0.65 2.61 PVC Tin Cu 95 8.28 PVC
4.3 1.00 32/0.20 x 4C 32/0.20 Tin Cu 0.65 2.61 PVC Tin Cu 95 8.95 PVC
5.1 1.50 30/0.25 x 1P 30/0.25 Tin Cu 0.70 2.98 PVC Tin Cu 95 8.62 PVC
5.2 1.50 30/0.25 x 4P 30/0.25 Tin Cu 0.70 2.98 PVC Tin Cu 95 12.42 PVC
5.3 1.50 30/0.25 x 2C 30/0.25 Tin Cu 0.70 2.98 PVC Tin Cu 95 8.62 PVC
5.4 1.50 30/0.25 x 4C 30/0.25 Tin Cu 0.70 2.98 PVC Tin Cu 95 10.06 PVC
5.5 1.50 30/0.25 x 5C 30/0.25 Tin Cu 0.70 2.98 PVC Tin Cu 95 11.01 PVC
6.1 2.50 50/0.25 x 2C 50/0.25 Tin Cu 0.75 3.54 PVC Tin Cu 95 9.75 PVC
6.2 2.50 50/0.25 x 3C 50/0.25 Tin Cu 0.75 3.54 PVC Tin Cu 95 10.39 PVC
7.1 4.00 56/0.30 x 2C 56/0.30 Tin Cu 0.75 4.09 PVC Tin Cu 95 10.95 PVC
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
2 Cores or 1 Pair
5. PVC Jacket
3. Braiding (Tin Cu.)
1. Sheathed Core
2. Mylar Tape
4. Polyester Yarn
1
2
1. Sheathed Core
5. PVC Jacket
3. Braiding (Tin Cu.)
2. Mylar Tape
4. Polyester Yarn
1
2
3
3
1 2
41. Sheathed Core
5. PVC Jacket
3. Braiding (Tin Cu.)
2. Mylar Tape
4. Polyester Yarn
http://www.southerncable.cc
24 Cores
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.