Top Banner
Insulated Panels New Zealand Kingspan KS1000 AWP CodeMark (CM20114) Details Version Q3 20 15 Contents: 1. Vertically-laid Details Go to page 2. Horizontally-laid Details Page 2 Page 2 8 Go to page
67

Kingspan KS1000 AWP CodeMark (CM20114) Dteails

Apr 14, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

Insulated Panels New Zealand

Kingspan KS1000 AWP CodeMark (CM20114) Details Version Q3 2015

Contents:

1. Vertically-laid Details Go to page

2. Horizontally-laid Details

Page 2

Page 28 Go to page

Page 2: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

AWP WALL VERTICAL - DRAWING LIST

22.12.15 -

AWP_VS_00 1 1 of 1 A4

JS

AWP WALL VERTICAL - DRAWING LIST

KS1000 AWP Vertical Std Q3 2015

DATE TITLE

DRG_REF

REVISION

22.12.15 AWP WALL VERTICAL - DRAWING LIST

AWP_VS_00

-

22.12.15 KS1000 AWP WALL PROFILE: MICRO-RIB & MINI-MICRO

AWP_VS_01

-

22.12.15 KS1000 AWP WALL PROFILE: EUROBOX & WAVE

AWP_VS_02

-

22.12.15 KS1000 AWP WALL PROFILE: PLANK

AWP_VS_03

-

22.12.15 WALL VERTICAL FIXINGS

AWP_VS_04

-

22.12.15 WALL VERTICAL SHEETING RAILS

AWP_VS_05

-

22.12.15 WALL VERTICAL - AWP BASE DETAIL

AWP_VS_06

-

22.12.15 WALL VERTICAL - EXTERNAL CORNER

AWP_VS_07

-

22.12.15 WALL VERTICAL - INTERNAL CORNER

AWP_VS_08

-

22.12.15 WALL VERTICAL ABUTMENT TO CONCRETE

AWP_VS_09

-

22.12.15 WALL VERTICAL- ABUTMENT TO CONCRETE

AWP_VS_10

-

22.12.15 WALL VERTICAL - EAVES GUTTER

AWP_VS_11

-

22.12.15 WALL VERTICAL - OVERHANGING EAVES GUTTER

AWP_VS_12

-

30.08.16 WALL VERTICAL - BOUNDARY GUTTER

AWP_VS_13

1

30.08.16

WALL VERTICAL - VERGE_1 AWP_VS_14

1

30.08.16

WALL VERTICAL - VERGE_2 AWP_VS_15

1

22.12.15 WALL VERTICAL - SKILLION DETAIL

AWP_VS_16

-

30.08.16 WALL VERTICAL TO HORIZONTAL STACK JOINT DETAIL

AWP_VS_17

1

30.08.16 WALL VERTICAL STACK JOINT DETAIL. VERTICAL DEFLECTION HEAD

AWP_VS_17A

1

30.08.16 WALL VERTICAL TO VERTICAL STACK JOINT DETAIL

AWP_VS_17b

1

29.11.16 WALL VERTICAL TO VERTICAL DEFLECTION STACK JOINT DETAIL

AWP_VS_17c

1

22.12.15 KS1000 AWP WALL VERTICAL - WINDOW DETAIL

AWP_VS_20

-

22.12.15 KS1000 AWP WALL VERTICAL - OVER HEAD DOOR DETAIL

AWP_VS_21

-

22.12.15

WALL VERTICAL LOUVRE DETAIL (VERT SECTION) AWP_VS_22

-

22.12.15

WALL VERTICAL LOUVRE DETAIL (HORIZ. SECTIONS) AWP_VS_23

-

22.12.15 WALL VERTICAL - PENETRATION DETAIL

AWP_VS_24

-

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_00, 8/12/2016 10:29:50 a.m

.

Page 2

Page 3: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

MICRO-RIB PANEL PROFILEEXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

1000mm PANEL MODULE

996 for 1000mm PANEL MODULE

MINI-MICRO PANEL PROFILE

1000mm PANEL MODULE

996 for 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

1

20

10

1.5

25 25 25

17

20

46

PA

NE

L T

HIC

KN

ES

S

FACTORY APPLIED WEATHER SEAL

17

20

46

1

8.3

4.2

25 25 25

1

PA

NE

L T

HIC

KN

ES

S

FACTORY APPLIED WEATHER SEAL

NOTE: ABOVE DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE TO

MANUFACTURING TOLERANCES. PRECISE

DIMENSIONS MUST ALWAYS BE

MEASURED FROM ACTUAL SAMPLES ALL

DIMENSIONS IN MILLIMETRES.

AVAILABLE PANEL

THICKNESSES

INSULATION CORE

50

80

100

140

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

KS1000 AWP WALL PROFILE:

MICRO-RIB & MINI-MICRO

22.12.15 -

AWP_VS_01 1:5 1 of 1 A4

JS

KS1000 AWP WALL PROFILE: MICRO-RIB & MINI-MICRO

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_01, 8/12/2016 10:29:51 a.m

.

Page 3

Page 4: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

EUROBOX PANEL PROFILE

1000mm PANEL MODULE

996 for 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

WAVE PANEL PROFILE

1000mm PANEL MODULE

996 for 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

17

20

46

1

50

25 25 25

0.75

PA

NE

L T

HIC

KN

ES

S

50

FACTORY APPLIED WEATHER SEAL

17

20

46

1

50

25

25 25 25

2.3

PA

NE

L T

HIC

KN

ES

S

FACTORY APPLIED WEATHER SEAL

AVAILABLE PANEL

THICKNESSES

50

80

100

140

NOTE: ABOVE DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE TO

MANUFACTURING TOLERANCES. PRECISE

DIMENSIONS MUST ALWAYS BE

MEASURED FROM ACTUAL SAMPLES ALL

DIMENSIONS IN MILLIMETRES.

INSULATION CORE

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

KS1000 AWP WALL PROFILE:

EUROBOX & WAVE

22.12.15 -

AWP_VS_02 1:5 1 of 1 A4

JS

KS1000 AWP WALL PROFILE: EUROBOX & WAVE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_02, 8/12/2016 10:29:51 a.m

.

Page 4

Page 5: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

PLANK PANEL PROFILE

Internal Liner Sheet

1000mm PANEL MODULE

996 for 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

17

20

1

100

25 25 25

PA

NE

L T

HIC

KN

ES

S

1.5

46

FACTORY APPLIED WEATHER SEAL

AVAILABLE PANEL

THICKNESSES

50

80

100

140

NOTE: ABOVE DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE TO

MANUFACTURING TOLERANCES. PRECISE

DIMENSIONS MUST ALWAYS BE

MEASURED FROM ACTUAL SAMPLES ALL

DIMENSIONS IN MILLIMETRES.

INSULATION CORE

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

KS1000 AWP WALL PROFILE:

PLANK

22.12.15 -

AWP_VS_03 1:5 1 of 1 A4

JS

KS1000 AWP WALL PROFILE: PLANK

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_03, 8/12/2016 10:29:52 a.m

.

Page 5

Page 6: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

RECOMMMENDED FASTENER LOCATIONS:

PATTERN A (STANDARD PRESSURE ZONE)

PATTERN B (HIGH PRESSURE ZONE)

NOTE: THE NUMBER OF FASTENERS

AND LOCATIONS DEPEND ON THE

ACTUAL DESIGN SUCTION LOAD

60

mm

M

IN

.

PANEL BEARING

WIDTH SUITABLE

FOR NO OF FIXINGS.

FACTORY APPLIED WEATHER

SEAL

CONCEALED PANEL

FIXING

DIRECTION OF LAY

VERTICAL PANEL JOINT & FASTENER LOCATIONS

DIRECTION OF PREVAILING WIND

(If Practicable)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL FIXINGS

22.12.15 -

AWP_VS_04 1:5 1 of 1 A4

JS

WALL VERTICAL FIXINGS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_04, 8/12/2016 10:29:52 a.m

.

Page 6

Page 7: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

MAIN FRAME CENTRES

MAIN STANCHION

HORIZONTAL SHEETING RAIL

STEELWORK BEARING WIDTH TO SUIT PANEL STEELWORK BEARING WIDTH

TO SUIT PANEL

VERTICAL POST COLD ROLLED CHANNEL OR SIMILAR

(if required to support girt members)

EAVES BEAM (DHS OR SIMILAR)

HORIZONTAL SHEETING RAIL

CONTINUOUS DHS OR SIMILAR

INSULATED PANELS

VERTICALLY LAID

MAIN STANCHION

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL SHEETING RAILS

22.12.15 -

AWP_VS_05 NTS 1 of 1 A4

JS

WALL VERTICAL SHEETING RAILS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_05, 8/12/2016 10:29:53 a.m

.

Page 7

Page 8: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN KS1000

AWP WALL PANEL

VERTICALLY LAID

INTERNAL CLOSER

FLASHING

0.5mm COIL

COATED BASE DRIP

FLASHING

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

FOAM SEAL

CONTINUOUS RUN OF

SILICONE SEALANT

CUT END COVER

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

GUN GRADE SEALANT

ACROSS JOIN, BACK SEALED

WITH 6x4mm BUTYL SEALANT

Max 300m

m O

verhang

STEP DETAIL

CONTINUOUS BASE

SUPPORT ANGLE

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

CONTINUOUS RUN OF

SILICONE SEALANT

KINGSPAN KS1000 AWP

WALL PANEL VERTICALLY

LAID

PEF ROD SEALED WITH

GUN GRADE SEALANT

CUT END COVER

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

0.5mm COIL

COATED BASE DRIP

FLASHING

GUN GRADE SEALANT

ACROSS JOIN, BACK SEALED

WITH 6x4mm BUTYL SEALANT

FLUSH WALL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - AWP BASE DETAIL

22.12.15 -

AWP_VS_06 1:5 1 of 1 A4

JS

WALL VERTICAL - AWP BASE DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_06, 8/12/2016 10:29:53 a.m

.

Page 8

Page 9: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN KS1000 AWP WALL

PANEL VERTICALLY LAID

0.5mm COIL COATED CORNER FLASHING

WITH 150mm SEALED OVERLAP OR

BUTT-STRAPS. SEALED WITH CONTINUOUS

RUN OF 6x4mm BUTYL SEALANT

DIRECTION OF LAY

DIR

EC

TIO

N O

F LA

Y

INTERNAL FLASHING WITH 150MM SEALED

OVERLAP OR BUTT-STRAPS. SEALED WITH

CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

FILL GAPS WITH CANISTER FR FOAM FILLER

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - EXTERNAL

CORNER

22.12.15 -

AWP_VS_07 1:5 1 of 1 A4

JS

WALL VERTICAL - EXTERNAL CORNER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_07, 8/12/2016 10:29:54 a.m

.

Page 9

Page 10: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN KS1000 AWP

WALL PANEL VERTICALLY

LAID.

0.5mm COIL COATED INTERNAL CORNER

FLASHING WITH 150mm SEALED

OVERLAP OR BUTT-STRAPS. SEALED

WITH CONTINUOUS RUN OF 6x4mm

BUTYL SEALANT

FILL GAPS WITH CANISTER FR FOAM FILLER

INTERNAL FLASHING SEALED WITH

CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

DIR

EC

TIO

N O

F L

AY

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - INTERNAL CORNER

22.12.15 -

AWP_VS_08 1:5 1 of 1 A4

JS

WALL VERTICAL - INTERNAL CORNER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_08, 8/12/2016 10:29:54 a.m

.

Page 10

Page 11: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

PEF ROD SEALED WITH

GUN GRADE SEALANT

0.5mm COIL COATED END FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS. SEALED TO

PANEL WITH CONTINUOUS RUN OF 6x4mm BUTYL

SEALANT

KINGSPAN KS1000 AWP VERTICALLY LAID. FIX CUT

END USING GALV. RECESSED WASHERS

CONTINUOUS RUN OF

SILICONE SEALANT

CONTINUOUS SUPPORT

ANGLE

6x4mm BUTYL SEALANT

FILL GAPS WITH

CANISTER FR

FOAM FILLER

FILL GAPS WITH

CANISTER FR

FOAM FILLER

PEF ROD SEALED WITH

GUN GRADE SEALANT

0.5mm COIL COATED END FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS. SEALED TO PANEL

WITH CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

KINGSPAN KS1000 AWP

VERTICALLY LAID

CONTINUOUS RUN OF

SILICONE SEALANT

CONTINUOUS SUPPORT ANGLE

CONTINUOUS SUPPORT ANGLE

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL ABUTMENT TO CONCRETE

22.12.15 -

AWP_VS_09 1:5 1 of 1 A4

JS

WALL VERTICAL ABUTMENT TO CONCRETE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_09, 8/12/2016 10:29:55 a.m

.

Page 11

Page 12: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN KS1000 AWP VERTICALLY LAID

CONTINUOUS RUN OF

SILICONE SEALANT

CONTINUOUS SUPPORT ANGLE

DPC LAYER BETWEEN FACE OF

CONCRETE AND UNDERSIDE OF PANEL

0.5mm COIL COATED STEEL END

FLASHING SEALED TO PANEL WITH

6x4mm BUTYL SEALANT.

CONTINUOUS RUN OF

SILICONE SEALANT TO

PAINTED TILT SLAB

6x4mm BUTYL SEALANT

DPC LAYER BETWEEN FACE OF CONCRETE

AND UNDERSIDE OF PANEL

CONTINUOUS RUN OF

SILICONE SEALANT TO

PAINTED TILT SLAB

0.5mm COIL COATED END FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS. SEALED TO PANEL

WITH CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

KINGSPAN KS1000 AWP

VERTICALLY LAID

CONTINUOUS RUN OF SILICONE

SEALANT

CONTINUOUS SUPPORT ANGLE

6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL- ABUTMENT TO

CONCRETE

22.12.15 -

AWP_VS_10 1:5 1 of 1 A4

JS

WALL VERTICAL- ABUTMENT TO CONCRETE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_10, 8/12/2016 10:29:55 a.m

.

Page 12

Page 13: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

FILL GAPS WITH CANISTER FR

FOAM FILLER

SITE APPLIED GUN GRADE

EAVES SEAL

75mm EAVES OVERHANG

CLOSED CELL FOAM EAVES FILLER

BLOCK

GUTTER BRACKET ATTACHED

TO PAINTED FASCIA BOARD

FIXED TO PURLINS

PRESSED STEEL GUTTER

INTERNAL FLASHING SEALED WITH

CONTINUOUS RUNS OF 6x4mm BUTYL

SEALANT

KINGSPAN KS1000 AWP WALL

PANEL VERTICALLY LAID

CONTINUOUS PROFILED

SPACER

AWP FILLER BLOCK WITH SITE

APPLIED GUN GRADE EDGE SEAL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - EAVES GUTTER

22.12.15 -

AWP_VS_11 1:5 1 of 1 A4

JS

WALL VERTICAL - EAVES GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_11, 8/12/2016 10:29:55 a.m

.

Page 13

Page 14: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

ADDITIONAL TREATMENT

REQUIRED IF UNDERSIDE

OF PANEL IS EXPOSED

INTERNAL

FLASHING

FILL GAPS WITH CANISTER

FR FOAM FILLER

0.5mm COIL COATED SOFFIT

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

KINGSPAN KS1000

RW ROOFING PANEL

FOAM AWP FILLER SEALED

ACROSS WITH SITE APPLIED

GUN GRADE EAVES SEAL

KS1000 AWP WALL

PANEL VERTICALLY LAID

EXTERNAL FLASHING

FLASHING TO SUIT LINER

MATERIAL. CUT AROUND

STRUCTURE AS

NECESSARY.

FLASHING TO SUIT EXT

MATERIAL. CUT AROUND

STRUCTURE AS NECESSARY.

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - OVERHANGING

EAVES GUTTER

22.12.15 -

AWP_VS_12 1:5 1 of 1 A4

JS

WALL VERTICAL - OVERHANGING

EAVES GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_12, 8/12/2016 10:29:56 a.m

.

Page 14

Page 15: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SITE APPLIED GUN GRADE

EAVES SEAL

FIXING AT CROWN

0.5mm COIL COATED EDGE

FLASHING

0.5mm COIL COATED CORNER

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

0.9mm GALV. CONTINUOUS STEEL

BRACKET FIXED TO BACK OF

GUTTER WITH 3 No. 4mm RIVETS

@200crs ALONG GUTTER

0.5mm COIL COATED EDGE FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

INSULATED GUTTER SITE

BUILT BY CONTRACTOR

AIR SEAL 6x4mm BUTYL

SEALANT

BUTYNOL GUTTER LINING

0.5mm COIL COATED PARAPET

FLASHING SEALED WITH 6x4mm BUTYL

SEALANT

PIR OR TIMBER INFILL BLOCK

75

GUTTER HIGH POINT

AWP FILLER SEALED

ACROSS JOIN WITH GUN

GRADE SEALANT

CONTINUOUS SPACER BLOCK

SET TO GUTTER FALLS

30

0m

m M

ax

75X125mm X 0.5mm COIL COATED STEEL

TRIM. STAGGER RIVETS AT 200 CTRS.

SEALED WITH 6x4mm BUTYL SEALANT

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - BOUNDARY GUTTER

30.08.16 1

AWP_VS_13 1:5 1 of 1 A4

JS

WALL VERTICAL - BOUNDARY GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_13, 8/12/2016 10:29:56 a.m

.

Page 15

Page 16: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DIRECTION

OF LAY

KS1000 AWP WALL PANEL

VERTICALLY LAID

FOAM AWP FILLER SEALED ACROSS

JOIN WITH GUN GRADE SEALANT

CONTINUOUS STEEL FIXING TAB

BY STEEL CONTRACTOR

6X4mm BUTYL SEALANT

* 6x4mm BUTYL SEALANT

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - VERGE_1

30.08.16 1

AWP_VS_14 1:3 1 of 1 A4

JS

WALL VERTICAL - VERGE_1

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_14, 8/12/2016 10:29:57 a.m

.

Page 16

Page 17: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DIRECTION

OF LAY

CONTINUOUS RUN OF 6x4mm

BUTYL SEALANT

CONTINUOUS STEEL FIXING TAB

BY STEEL CONTRACTOR

AWP FILLER SEALED ACROSS

JOIN WITH GUN GRADE SEALANT

KS1000 AWP WALL PANEL

VERTICALLY LAID

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

* 6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - VERGE_2

30.08.16 1

AWP_VS_15 1:3 1 of 1 A4

JS

WALL VERTICAL - VERGE_2

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_15, 8/12/2016 10:29:57 a.m

.

Page 17

Page 18: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED PARAPET

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

PIR OR TIMBER INFILL

BLOCK

5

° m

in

FOAM AWP FILLER SEALED ACROSS

JOIN WITH GUN GRADE SEALANT

FIXING AT PAN

KS1000 AWP WALL PANEL

FOAM RIDGE FILLER SEALED

TOP & BOTTOM WITH GUN

GRADE SEALANT

INTERNAL FLASHING

FILL GAPS WITH CANISTER FR FOAM FILLER

KINGSPAN KS1000 RW

ROOFING PANEL

0.5mm COIL COATED APRON

FLASHING

0.5mm COIL COATED CUT

EDGE PROTECTION FLASHING

6x4mm BUTYL

SEALANT

GUN GRADE SEALANT

ACROSS JOIN, BACK SEALED

WITH 6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - SKILLION DETAIL

22.12.15 -

AWP_VS_16 1:5 1 of 1 A4

JS

WALL VERTICAL - SKILLION DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_16, 8/12/2016 10:29:58 a.m

.

Page 18

Page 19: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED DRIP FLASHING SEALED TO

FACE OF PANEL WITH 6x4mm BUTYL SEALANT

KS1000 AWP PANEL VERTICALLY LAID

FIRE RATED CANISTER INSULATION

KS1000 AWP PANEL

HORIZONTALLY LAID

CUT END COVER FLASHING

6 m

in

GUN GRADE SEALANT ACROSS

JOIN, BACK SEALED WITH 6x4mm

BUTYL SEALANT

*6x4mm BUTYL SEALANT

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL TO HORIZONTAL

STACK JOINT DETAIL

30.08.16 1

AWP_VS_17 1:3 1 of 1 A4

JS

WALL VERTICAL TO HORIZONTAL STACK JOINT DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_17, 8/12/2016 10:29:58 a.m

.

Page 19

Page 20: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED DRIP FLASHING

SEALED TO FACE OF PANEL WITH

6x4mm BUTYL SEALANT

KS1000 AWP PANEL VERTICALLY LAID

CUT END COVER FLASHING

AWP JOINT FILLER AND SILICONE SEALANT

TO MALE JOINT. BACK SEALED TO FLASHING

WITH 6x4MM BUTYL SEALANT

LOOSE FILL INSULATION TO

DEFLECTION HEAD

PANEL SUPPORT FIXED THROUGH TO

HORIZONTAL SUPPORTS NOT TOP

PLATE ; TO ALLOW FOR DEFLECTION

CONTINUOUS GALV

SUPPORT PLATE

deflection required

GUN GRADE SEALANT

ACROSS JOIN, BACK SEALED

WITH 6x4mm BUTYL SEALANT

MA

X 3

00

mm

O

VE

RH

AN

G

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL STACK JOINT

DETAIL. VERTICAL DEFLECTION HEAD

30.08.16 1

AWP_VS_17A 1:5 1 of 1 A4

JS

WALL VERTICAL STACK JOINT DETAIL.

VERTICAL DEFLECTION HEAD

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_17a, 8/12/2016 10:29:59 a.m

.

Page 20

Page 21: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED DRIP FLASHING SEALED TO

FACE OF PANEL WITH 6x4mm BUTYL SEALANT *

KS1000 AWP PANEL

VERTICALLY LAID

CUT END COVER FLASHING

AWP JOINT FILLER AND SILICONE

SEALANT TO MALE JOINT

FIRE RATED CANISTER INSULATION

APPLIED AS PANEL IS PLACED

GUN GRADE SEALANT ACROSS JOINT,

BACK SEALED WITH 6x4mm BUTYL

SEALANT

6x4mm BUTYL SEALANT

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL TO VERTICAL STACK

JOINT DETAIL

30.08.16 1

AWP_VS_17b 1:3 1 of 1 A4

JS

WALL VERTICAL TO VERTICAL STACK JOINT DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_17b, 8/12/2016 10:29:59 a.m

.

Page 21

Page 22: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED DRIP FLASHINGS

WELTED TO ALLOW MOVEMENT. SEAL TO

FACE OF PANEL WITH 6x4mm BUTYL SEALANT

KS1000 AWP PANEL VERTICALLY LAID

CUT END COVER FLASHING

AWP JOINT FILLER AND GUN GRADE SEALANT

TO MALE JOINT. BACK SEALED TO FLASHING

WITH 6x4MM BUTYL SEALANT

LOOSE FILL INSULATION TO

DEFLECTION HEAD

PANEL SUPPORT FIXED THROUGH TO

HORIZONTAL SUPPORTS NOT TOP

PLATE ; TO ALLOW FOR DEFLECTION

GUN GRADE SEALANT ACROSS JOINT,

BACK SEALED WITH 6x4mm BUTYL

SEALANT

MA

X 3

00

mm

O

VE

RH

AN

G

2-WAY SEISMIC CONNECTION

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL TO VERTICAL

DEFLECTION STACK JOINT DETAIL

29.11.16 1

AWP_VS_17c 1:3 1 of 1 A4

JS

WALL VERTICAL TO VERTICAL DEFLECTION STACK JOINT DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_17c, 8/12/2016 10:30:00 a.m

.

Page 22

Page 23: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

CUT END COVER FLASHING

0.5mm COIL COATED SILL FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

WINDOW SUPPORT

FRAME

WINDOW UNIT BY OTHERS

0.5mm COIL COATED HEAD FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

PF BACKING ROD WITH GUN GRADE

SEALANT. BY WINDOW INSTALLER

KS1000 AWP PANEL

VERTICALLY LAID

KS1000 AWP PANEL VERTICALLY LAID

GUN GRADE SEALANT ACROSS

JOIN, BACK SEALED WITH

6x4mm BUTYL SEALANT

WINDOW UNIT BY OTHERS

WINDOW JAMB FRAME

PF BACKING ROD WITH GUN GRADE

SEALANT. BY WINDOW INSTALLER

KS1000 AWP WALL PANEL

VERTICALLY LAID

0.5mm COIL COATED JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

FIXINGS AT 500mm CTRS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

KS1000 AWP WALL VERTICAL -

WINDOW DETAIL

22.12.15 -

AWP_VS_20 1:5 1 of 1 A4

JS

KS1000 AWP WALL VERTICAL - WINDOW DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_20, 8/12/2016 10:30:00 a.m

.

Page 23

Page 24: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DOOR HEAD SUPPORT

FRAME

KS1000 AWP PANEL VERTICALLY LAID

0.5mm COIL COATED HEAD

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

CUT END COVER FLASHING

GUN GRADE SEALANT ACROSS

JOIN, BACK SEALED WITH 6x4mm

BUTYL SEALANT

KS1000 AWP PANEL

VERTICALLY LAID

0.5mm COIL COATED 2 PART JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

DOOR BY OTHERS

DOOR GUIDE BY

OTHERS

STRUCTURAL DOOR

JAMB BY OTHERS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

KS1000 AWP WALL VERTICAL - OVER

HEAD DOOR DETAIL

22.12.15 -

AWP_VS_21 1:5 1 of 1 A4

JS

KS1000 AWP WALL VERTICAL -

OVER HEAD DOOR DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_21, 8/12/2016 10:30:01 a.m

.

Page 24

Page 25: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

LOUVRE SUPPORT FRAME

CUT END COVER FLASHING

6 m

in

KS1000 AWP PANEL VERTICALLY LAID

0.5mm COIL COATED HEAD FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

GUN GRADE SEALANT ACROSS PANEL JOINT,

BACK SEALED WITH 6x4mm BUTYL SEALANT

0.5mm COIL COATED SILL FLASHING

AWP FILLER SEALED TOP & BOTTOM

WITH GUN GRADE SEALANT. SILICONE

SEALANT ACROSS JOINT

SILICONE SEALANT TO PERIMETER

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL LOUVRE DETAIL

(VERT SECTION)

22.12.15 -

AWP_VS_22 1:3 1 of 1 A4

JS

WALL VERTICAL LOUVRE DETAIL (VERT SECTION)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_22, 8/12/2016 10:30:01 a.m

.

Page 25

Page 26: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KS1000 AWP PANEL

VERTICALLY LAID

0.5mm COIL COATED JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

LOUVRE SUPPORT FRAME

SILICONE SEALANT

LOUVRE UNIT

KS1000 AWP PANEL

VERTICALLY LAID (Male End)

LOUVRE SUPPORT FRAME

SILICONE SEALANT.

LOUVRE UNIT

(OPTION A)

(OPTION B)

KS1000 AWP PANEL

VERTICALLY LAID (Female End)

FIXINGS AT 500mm CTRS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL LOUVRE DETAIL

(HORIZ. SECTIONS)

22.12.15 -

AWP_VS_23 1:3 1 of 1 A4

JS

WALL VERTICAL LOUVRE DETAIL (HORIZ. SECTIONS)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_23, 8/12/2016 10:30:02 a.m

.

Page 26

Page 27: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SITE APPLIED NON-COMBUSTIBLE INSULATION

PROPRIETARY INSITU WEATHERING SYSTEM

BONDED TO PANELS EXTERNAL SHEET,

COLOUR TO MATCH EXTERNAL PANEL.

PIPE / DUCTING

HOLE SITE CUT TO ACCOMMODATE

PIPE / DUCTING ETC

INTERNAL COVER FLASHING SEALED

WITH 6x4mm BUTYL SEALANT

ALTERNATIVE STANDARD TEMPERATURE

KS1000 AWP INSULATED WALL

PANEL (VERTICALLY LAID)

SITE APPLIED

NON-COMBUSTIBLE INSULATION

HOLE SITE CUT TO ACCOMMODATE PIPE /

DUCTING ETC. LINE WITH GALVANISED SOAKER.

"DEKTITE" FLEXIBLE PIPE FLASHING OR

SIMILAR TO SUIT CONDITIONS. (to 115°C max)

PIPE / DUCTING

KS1000 AWP INSULATED WALL

PANEL (VERTICALLY LAID)

INTERNAL COVER FLASHING SEALED

WITH 6x4mm BUTYL SEALANT

HIGH TEMPERATURE

Max Unsupported Circular

Penetration - 300mm

INTERNAL COVER FLASHING SEALED

WITH 6x4mm BUTYL SEALANT

"DEKTITE" FLEXIBLE PIPE FLASHING

OR SIMILAR TO SUIT CONDITIONS.

PIPE / DUCTING

STANDARD TEMPERATURE

KS1000 AWP INSULATED WALL

PANEL (VERTICALLY LAID)

FLEXIBLE PIPE FLASHING PROVIDES A COMPLETELY

WEATHERPROOF SOLUTION FOR PIPE OPENINGS THROUGH A

WALL. THEY CAN BE MOULDED BY HAND TO SUIT THE SHEET

PROFILE, BEDDED IN WEATHER SEALANT & FIXED TO THE WALL

SHEET.

NOTE: MAXIMUM CIRCULAR HOLE SIZE TO BE 300MM.

PENETRATIONS GREATER WILL REQUIRE ADDITIONAL

SUPPORTING STEEL.

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL VERTICAL_STD Q3 2015

WALL VERTICAL - PENETRATION

DETAIL

22.12.15 -

AWP_VS_24 1:5 1 of 1 A4

JS

WALL VERTICAL - PENETRATION DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all V

ertical\K

S1000 A

WP

W

all V

ertical_S

td Q

3 2015.dw

g, A

WP

_V

S_24, 8/12/2016 10:30:02 a.m

.

Page 27

Page 28: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

DRAWING LIST

26.08.16 1

AWP_HS_00 1 1 of 1 A4

-

DRAWING LIST

DATE DETAIL NAME

DRG_REF

REVISION

22.12.15 DRAWING LIST

AWP_HS_00

-

22.12.15 AWP WALL PROFILE: MICRO-RIB & MINI-MICRO

AWP_HS_01

-

22.12.15 AWP WALL PROFILE: EUROBOX & WAVEAWP_HS_02

-

22.12.15 AWP WALL PROFILE: PLANK

AWP_HS_03

-

22.12.15 AWP WALL HORIZONTAL FIXING

AWP_HS_04

-

22.12.15 AWP WALL HORIZONTAL SHEETING SUPPORTS

AWP_HS_05

-

22.12.15

AWP WALL BASE (PANEL BEARER) AWP_HS_06

-

22.12.15 AWP WALL BASE CHANNEL DETAIL

AWP_HS_06a

-

22.12.15 AWP BASE SUPPORT 3

AWP_HS_07

-

26.08.16 AWP WALL - EXTERNAL CORNER

AWP_HS_08

1

22.12.15 EXTERNAL PRE-FORMED CORNER

AWP_HS_08a

-

22.12.15

AWP WALL PREFORMED CORNER DETAIL (ISOMETRIC) AWP_HS_08b

-

26.08.16 AWP WALL - INTERNAL CORNER

AWP_HS_09

1

26.08.16

AWP WALL TOP HAT JOIN DOUBLE FIXING (PLAN) AWP_HS_10

1

26.08.16 AWP WALL TOP HAT JOIN SEAL DETAIL

AWP_HS_11

1

22.12.15 AWP LONGSPAN TOPHAT DETAIL TO UC COLUMN

AWP_HS_11a

-

26.08.16 AWP WALL FACE ALIGNED WITH CONCRETE

AWP_HS_12

1

22.12.15 AWP WALL FACE FIXED OVER CONCRETE

AWP_HS_13

-

22.12.15 AWP WALL EAVES GUTTER

AWP_HS_14

-

22.12.15 OVERHANGING EAVES GUTTER

AWP_HS_15

-

22.12.15 AWP WALL PARAPET GUTTER

AWP_HS_16

-

22.12.15 AWP WALL PARAPET VERGE

AWP_HS_17

-

22.12.15 PARAPET VERGE WITH PANEL BEARER

AWP_HS_18

-

22.12.15

AWP WALL VERGE DETAIL (RW MALE EDGE) AWP_HS_19

-

22.12.15

AWP WALL VERGE DETAIL (RW FEMALE EDGE) AWP_HS_20

-

22.12.15

AWP WALL SKILLION DETAIL (PANEL BEARER) AWP_HS_21

-

22.12.15

KS1000 AWP WALL HORIZONTAL TO VERTICAL STACK JOINT DETAIL (PANEL BEARER) AWP_HS_22

-

26.08.16 KS1000 AWP WALL SEISMIC JOINT DETAIL

AWP_HS_22 a

1

22.12.15

AWP WALL: INTEGRATED HORIZONTAL WINDOW DETAIL - 50mm ONLY (VERTICAL SECTION) AWP_HS_23

-

22.12.15 AWP WALL PANEL: INTEGRATED HORIZONTAL WINDOW SECTION DETAIL - 50mm ONLY

AWP_HS_23a

-

22.12.15 SITE CUT PANEL DETAIL

AWP_HS_24

-

22.12.15

AWP WALL WINDOW DETAIL (Base Channel) AWP_HS_25

-

26.08.16

AWP WALL WINDOW DETAIL (horizontal section) AWP_HS_25a

1

22.12.15

AWP WALL PERSONNEL DOOR DETAIL (PANEL BEARER) AWP_HS_26

-

22.12.15

AWP WALL OVER HEAD DOOR DETAIL (Panel Bearer) AWP_HS_27

-

22.12.15 AWP WALL INTEGRATED LOUVRE DETAIL

AWP_HS_28

-

22.12.15 AWP WALL PENETRATION DETAIL

AWP_HS_29

-

22.12.15 AWP WALL BASE CHANNEL SUPPORT DETAIL

AWP_HS_30

-

22.12.15 AWP WALL PANEL BEARER DETAIL

AWP_HS_30a

-

22.12.15

AWP WALL RECESSED WASHER DETAIL (RECW09G) AWP_HS_31

-

KS1000 AWP WALL HORIZONTAL_STD Q3 2015.DWG

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_00, 8/12/2016 10:37:24 a.m

.

Page 28

Page 29: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

MICRO-RIB PANEL PROFILE

1000mm PANEL MODULE

996 FOR 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

MINI-MICRO PANEL PROFILE

1000mm PANEL MODULE

996 FOR 1000mm PANEL MODULE

FACTORY APPLIED WEATHER SEAL

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

1

20

10

1.5

25 25 25

17

20

46

Panel T

hickness

FACTORY APPLIED WEATHER SEAL

NOTE: DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE

TO MANUFACTURING TOLERANCES.

PRECISE DIMENSIONS MUST ALWAYS

BE MEASURED FROM ACTUAL SAMPLES

ALL DIMENSIONS IN MILLIMETRES.

AVAILABLE PANEL

THICKNESSES

INSULATION CORE

50

80

100

140

17

20

46

1

8.3

4.2

25 25 25

1

Panel T

hickness

FACTORY APPLIED WEATHER SEAL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PROFILE: MICRO-RIB & MINI-MICRO

22.12.15 -

AWP_HS_01 1:5 1 of 1 A4

-

AWP WALL PROFILE: MICRO-RIB & MINI-MICRO

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_01, 8/12/2016 10:37:27 a.m

.

Page 29

Page 30: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

EUROBOX PANEL PROFILE

1000mm PANEL MODULE

996 FOR 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

WAVE PANEL PROFILE

1000mm PANEL MODULE

996 FOR 1000mm PANEL MODULE

EXTERNAL WEATHER

SHEET

INTERNAL LINER SHEET

17

20

46

1

50

25 25 25

0.75

Panel T

hickness

50

FACTORY APPLIED WEATHER SEAL

NOTE: DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE

TO MANUFACTURING TOLERANCES.

PRECISE DIMENSIONS MUST ALWAYS

BE MEASURED FROM ACTUAL SAMPLES

ALL DIMENSIONS IN MILLIMETRES.

AVAILABLE PANEL

THICKNESSES

INSULATION CORE

50

80

100

140

17

20

46

1

50

25

25 25 25

2.3

Panel T

hickness

FACTORY APPLIED WEATHER SEAL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PROFILE: EUROBOX & WAVE

22.12.15 -

AWP_HS_02 1:5 1 of 1 A4

-

AWP WALL PROFILE: EUROBOX & WAVE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_02, 8/12/2016 10:37:28 a.m

.

Page 30

Page 31: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

PLANK PANEL PROFILES

1000mm PANEL MODULE

996 FOR 1000mm PANEL MODULE

EXTERNAL WEATHER SHEETINTERNAL LINER SHEET

17

20

1

100

25 25 25

Pa

ne

l T

hickn

ess

1.5

46

FACTORY APPLIED WEATHER SEAL

NOTE: DIMENSIONS ARE NOMINAL,

ACTUAL DIMENSIONS WILL VARY DUE

TO MANUFACTURING TOLERANCES.

PRECISE DIMENSIONS MUST ALWAYS

BE MEASURED FROM ACTUAL SAMPLES

ALL DIMENSIONS IN MILLIMETRES.

AVAILABLE PANEL

THICKNESSES

INSULATION CORE

50

80

100

140

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PROFILE: PLANK

22.12.15 -

AWP_HS_03 1:5 1 of 1 A4

-

AWP WALL PROFILE: PLANK

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_03, 8/12/2016 10:37:29 a.m

.

Page 31

Page 32: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

RECOMMMENDED FASTENER LOCATIONS

PATTERN A (SINGLE FASTENERS)

PATTERN B (SINGLE / DOUBLE FASTENERS)

NOTE: FASTENER LOCATIONS DEPEND

ON THE ACTUAL DESIGN SUCTION LOAD

Min. Steel Bearing Face 140mm

Min. Steel Bearing Face 200mm

Min. Steel Bearing Face 50mm

Minimum Fixing Spacings

1515 20 min

1515 20 20

HIGH WIND LOADS

STANDARD WIND LOADS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL HORIZONTAL FIXING

22.12.15 -

AWP_HS_04 1:5 1 of 1 A4

-

AWP WALL HORIZONTAL FIXING

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_04, 8/12/2016 10:37:29 a.m

.

Page 32

Page 33: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

MAIN FRAME CENTRES

PORTAL BEAM

STEELWORK BEARING WIDTH TO SUIT PANEL STEELWORK BEARING WIDTH TO SUIT

PANEL

INTERMEDIATE SUPPORT POST

(if required)

EAVES BEAM (DHS OR SIMILAR)

HORIZONTAL SHEETING RAIL

CONTINUOUS DHS OR SIMILAR

INSULATED PANELS

HORIZONTALLY LAID

PORTAL BEAM

INTERMEDIATE

SUPPORT POST

(if required)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL HORIZONTAL SHEETING

SUPPORTS

22.12.15 -

AWP_HS_05 NTS 1 of 1 A4

-

AWP WALL HORIZONTAL SHEETING SUPPORTS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_05, 8/12/2016 10:37:30 a.m

.

Page 33

Page 34: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DPC LAYER BETWEEN FACE OF

CONCRETE AND FLASHING

KINGSPAN AWP PANEL BEARER

0.5mm COIL COATED BASE DRIP

FLASHING.

CONTINUOUS RUN

OF GUN GRADE

SEALANT

0.5mm COIL COATED

BASE DRIP FLASHING

KINGSPAN KS1000 AWP

WALL PANEL

HORIZONTALLY LAID

INTERNAL CLOSER

FLASHING

CONTINUOUS RUNS OF

6x4mm BUTYL SEALANT

INTERMEDIATE SUPPORT

OPTION B BASE CHANNEL

CONTINUOUS RUN OF

GUN GRADE SEALANT

CONTINUOUS AWP BASE CHANNEL

(BC)

0.5mm COIL COATED

BASE DRIP FLASHING

INTERNAL CLOSER FLASHING

CONTINUOUS RUN OF

6x4mm BUTYL

SEALANT

INTERMEDIATE SUPPORT

DPC LAYER BETWEEN FACE OF

CONCRETE AND FLASHING

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL BASE (PANEL BEARER)

22.12.15 -

AWP_HS_06 1:2 1 of 1 A4

-

AWP WALL BASE (PANEL BEARER)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_06, 8/12/2016 10:37:31 a.m

.

Page 34

Page 35: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

INTERNAL CLOSER FLASHING

0.5mm COIL COATED

BASE DRIP FLASHING

CONTINUOUS RUNS OF GUN

GRADE SEALANT

CONTINUOUS AWP BASE CHANNEL (BC)

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL BASE CHANNEL DETAIL

22.12.15 -

AWP_HS_06a 1:2 1 of 1 A4

-

AWP WALL BASE CHANNEL DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_06a, 8/12/2016 10:37:32 a.m

.

Page 35

Page 36: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED BASE DRIP FLASHING

DPC LAYER BETWEEN FACE OF

CONCRETE AND FLASHING

KINGSPAN AWP PANEL BEARER

CONTINUOUS RUNS OF

6x4mm BUTYL SEALANT

CONTINUOUS RUN OF GUN GRADE SEALANT

INTERNAL BASE FLASHING

OPTION B BASE CHANNEL

KINGSPAN AWP BASE CHANNEL (BC)

0.5mm COIL COATED

BASE DRIP FLASHING

DPC LAYER BETWEEN FACE OF

CONCRETE AND FLASHING

KINGSPAN KS1000 AWP WALL

PANEL HORIZONTALLY LAID

CONTINUOUS RUNS OF

6x4mm BUTYL SEALANT

CONTINUOUS RUN OF

GUN GRADE SEALANT

INTERNAL BASE FLASHING

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP BASE SUPPORT 3

22.12.15 -

AWP_HS_07 1:2 1 of 1 A4

-

AWP BASE SUPPORT 3

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_07, 8/12/2016 10:37:32 a.m

.

Page 36

Page 37: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN KS1000 AWP WALL PANEL

HORIZONTALLY LAID

0.5mm COIL COATED EXTERNAL CORNER FLASHING

AWP FILLERS SEALED ACROSS THE

MALE JOIN WITH GUN GRADE SEALANT

FILL GAPS WITH FR FOAM FILLER

INTERNAL FLASHING SEALED WITH

CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

6x4mm BUTYL SEALANT *

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL - EXTERNAL CORNER

26.08.16 1

AWP_HS_08 1:3 1 of 1 A4

-

AWP WALL - EXTERNAL CORNER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_08, 8/12/2016 10:37:33 a.m

.

Page 37

Page 38: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

Dim. A

Dim

. B

ALL ABOVE DIMENSIONS ARE TO THE EXTERNAL FACE

OF THE PANEL.

INTERNAL ANGLES = 82 DEG. TO 152 DEG.

MAXIMUM LENGTH OF TOTAL CRANK MUST NOT EXCEED

2400MM. MAX UNSUPPORTED CANTILEVER IS 1000MM.

MINIMUM MAXIMUM

300mm 1200mm

8

2

°

-

1

5

2

°

DIMENSION A

300mm 1200mmDIMENSION B

SINGLE CRANKED CORNER

REFER TO KINGSPAN FOR

MAXIMUM PRACTICAL SIZES

Dim. B

Dim

. C

Dim

. A

8

2

°

-

1

5

2

°

8

2

°

-

1

5

2

°

ALL DIMENSIONS ARE TO THE EXTERNAL FACE OF THE PANEL.

REFER KINGSPAN TECHNICAL FOR MAX DIMENSIONS.

INTERNAL ANGLES = 82 deg. to 152 deg.

DOUBLE CRANKED CORNER

MINIMUM MAXIMUM

300mm 1200mmDIMENSION A

300mm 1200mmDIMENSION B

300mm 1200mmDIMENSION C

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

EXTERNAL PRE-FORMED CORNER

22.12.15 -

AWP_HS_08a 1:5 1 of 1 A4

-

EXTERNAL PRE-FORMED CORNER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_08a, 8/12/2016 10:37:34 a.m

.

Page 38

Page 39: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KS1000 AWP Pre-formed Units

ALL DIMENSIONS ARE TO THE EXTERNAL FACE OF THE PANEL.

INTERNAL ANGLES = 82 DEG. TO 152 DEG.

MAXIMUM LENGTH OF TOTAL CRANK MUST NOT EXCEED 2400mm.

MAX UNSUPPORTED CANTILEVER = 1000mm.

MINIMUM MAXIMUM

300mm 1200mmDIMENSION A

300mm 1200mmDIMENSION B

SINGLE CRANKED CORNER

D

im

.

B

D

i

m

.

A

10

00

82° - 152°

DOUBLE CRANKED CORNER

D

im

.

B

D

i

m

.

A

1000

82° - 152°

D

i

m

.

C

ALL DIMENSIONS ARE TO THE EXTERNAL FACE OF THE PANEL.

REFER KINGSPAN TECHNICAL FOR MAX DIMENSIONS.

INTERNAL ANGLES = 82 deg. to 152 deg.

MINIMUM MAXIMUM

300mm 1200mmDIMENSION A

300mm 1200mmDIMENSION B

300mm 1200mmDIMENSION C

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PREFORMED CORNER

DETAIL (ISOMETRIC)

22.12.15 -

AWP_HS_08b N.T.S 1 of 1 A4

-

AWP WALL PREFORMED CORNER DETAIL (ISOMETRIC)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_08b, 8/12/2016 10:37:35 a.m

.

Page 39

Page 40: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

FILL GAPS WITH FR FOAM FILLER

AWP FILLERS SEALED ACROSS THE MALE JOINT WITH

GUN GRADE SEALANT

KINGSPAN KS1000 AWP WALL PANEL

HORIZONTALLY LAID

0.5mm COIL COATED INTERNAL CORNER FLASHING

SEALED WITH CONTINUOUS RUN

OF 6x4mm BUTYL SEALANT *

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL - INTERNAL CORNER

26.08.16 1

AWP_HS_09 1:3 1 of 1 A4

-

AWP WALL - INTERNAL CORNER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_09, 8/12/2016 10:37:35 a.m

.

Page 40

Page 41: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

100

27

35 30 35

0.5mm Galv Butt Strap Connector FOR

TOPHAT JOINTS

Standard Length 3.0m

MIN. STEEL BEARING FACE 140mm

40mm max

35mm 35mm

BEARING SURFACE

MIN 50mm

INFILL FOAM (SITE APPLIED)

AWP JOINT FILLER AND GUN

GRADE SEALANT TO MALE JOINT

FOLDED STEEL TOP HAT FLASHING (TOP-HAT A)

6x4mm BUTYL SEALANT *

SNAP-ON COVER FLASHING (FLUSH)

VERTICAL SUPPORT (BY

STEEL SUB-CONTRACTOR)

BUBBLE GASKET (SITE APPLIED)

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

Isometric

TYPICAL TOPHAT BASE DETAIL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL TOP HAT JOIN DOUBLE

FIXING (PLAN)

26.08.16 1

AWP_HS_10 1:2 1 of 1 A4

-

AWP WALL TOP HAT JOIN DOUBLE FIXING (PLAN)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_10, 8/12/2016 10:37:36 a.m

.

Page 41

Page 42: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL TOP HAT JOIN SEAL

DETAIL

26.08.16 1

AWP_HS_11 1:1 1 of 1 A4

-

BUBBLE GASKET (VJ2)

STRUCTURE (By Others)

GUN GRADE SEALANT ACROSS

JOIN

AWP FOAM FILLER (3Fill)

SILICONE BACK SEAL

(high humidity only)

FACTORY APPLIED

AIR SEAL

TOP HAT COVER FLASHING

TOP HAT FLASHING INSERT

6x4mm BUTYL SEALANT *

PIR INFILL BLOCK

AWP WALL TOP HAT JOIN SEAL DETAIL

KS1000 AWP WALL

PANEL (cut away)

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_11, 8/12/2016 10:37:45 a.m

.

Page 42

Page 43: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

500M

mm

M

AX

IM

UM

C

EN

TR

ES

500m

m M

AX

IM

UM

C

EN

TR

ES

HORIZONTAL PANEL JOINT

TOP HAT JOINT CLEATS AT 500mm MAX CTRS

DRIP FLASHING

KS1000 AWP HORIZONTALLY LAID

0.5mm GALV BUTT STRAP

CONNECTOR

MIN. STEEL BEARING FACE 140mm

TOP HAT SUPPORT CLEATS

AT 500mm MAX CTRS

AVEX RIVETS

VERTICAL TOP HAT

6x4mm DIA BUTYL RUBBER SEAL

TOP HAT FIXED TO TOP HAT SUPPORT CLEATS

VERTICAL TOP HAT INSERT

PA

NE

L T

HIC

KN

ES

S

EXPLODED VIEW

MIN. STEEL BEARING FACE 140mm

PA

NE

L T

HIC

KN

ES

S

ASSEMBLED VIEW

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP LONGSPAN TOPHAT DETAIL

TO UC COLUMN

22.12.15 -

AWP_HS_11a nts 1 of 1 A4

-

AWP LONGSPAN TOPHAT DETAIL TO UC COLUMN

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_11a, 8/12/2016 10:37:47 a.m

.

Page 43

Page 44: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

FILL GAPS WITH FR FOAM FILLER

PF ROD SEALED WITH GUN GRADE SEALANT

0.5mm COIL COATED STEEL END FLASHING

SEALED TO PANEL WITH 6x4mm BUTYL SEALANT.

AWP FILLERS SEALED ACROSS THE

JOIN WITH GUN GRADE SEALANT

6x4mm BUTYL SEALANT *

CONTINUOUS RUN OF

GUN GRADE SEALANT

6x4mm BUTYL SEALANT

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL FACE ALIGNED WITH CONCRETE

26.08.16 1

AWP_HS_12 1:2 1 of 1 A4

-

AWP WALL FACE ALIGNED WITH CONCRETE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_12, 8/12/2016 10:37:48 a.m

.

Page 44

Page 45: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DPC LAYER BETWEEN TOP OF

CONCRETE AND UNDERSIDE OF PANEL

0.5mm COIL COATED STEEL END

FLASHING SEALED TO PANEL WITH

6x4mm BUTYL SEALANT.

CONTINUOUS RUN OF

GUN GRADE SEALANT

AWP FILLERS SEALED ACROSS THE

JOIN WITH GUN GRADE SEALANT

CONTINUOUS RUN OF

GUN GRADE SEALANT

6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL FACE FIXED OVER CONCRETE

22.12.15 -

AWP_HS_13 1:2 1 of 1 A4

-

AWP WALL FACE FIXED OVER CONCRETE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_13, 8/12/2016 10:37:49 a.m

.

Page 45

Page 46: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

FILL GAPS WITH FR FOAM FILLER

KINGSPAN KS1000 AWP PANEL

HORIZONTALLY LAID

GUTTER BRACKET ATTACHED TO PAINTED

FASCIA BOARD, FIXED TO PURLINS

PRESSED STEEL GUTTER

SEAL INTERNALLY WITH CONTINUOUS RUNS

OF 6x4mm BUTYL SEALANT

CONTINUOUS PROFILED SPACER

SITE APPLIED GUN GRADE

SEALANT ACROSS JOIN

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL EAVES GUTTER

22.12.15 -

AWP_HS_14 1:2 1 of 1 A4

-

AWP WALL EAVES GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_14, 8/12/2016 10:37:50 a.m

.

Page 46

Page 47: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

SITE APPLIED GUN GRADE

SEALANT EAVES SEAL

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

75mm EAVES OVERHANG

FIXING AT CROWN

GUTTER BRACKET ATTACHED TO

FASCIA BOARD FIXED TO PURLINS

PRESSED STEEL GUTTER

CLOSED CELL FOAM

EAVES FILLER BLOCK

SILICONE TO SEAM (if required)

INTERNAL FLASHING

EXTERNAL FLASHING

0.5mm COIL COATED

SOFFIT FLASHING

KINGSPAN KS1000 RW

ROOFING PANEL

ADDITIONAL TREATMENT REQUIRED IF

UNDERSIDE OF PANEL IS EXPOSED

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

KINGSPAN KS1000 AWP

PANEL HORIZONTALLY LAID

INTERMEDIATE SUPPORT

STRUCTURE

FLASHING TO SUIT LINER

MATERIAL. CUT AROUND

STRUCTURE AS NECESSARY.

FILL GAPS WITH FR

FOAM FILLER

FLASHING TO SUIT EXT

MATERIAL. CUT AROUND

STRUCTURE AS NECESSARY.

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

OVERHANGING EAVES GUTTER

22.12.15 -

AWP_HS_15 1:5 1 of 1 A4

-

OVERHANGING EAVES GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_15, 8/12/2016 10:37:50 a.m

.

Page 47

Page 48: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

5

° m

in

0.5mm COIL COATED PARAPET FLASHING

SEALED WITH CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

INFILL BLOCK

FILL GAPS WITH CANISTER

FR FOAM FILLER

0.5mm COIL COATED EDGE FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

KS1000 AWP PARAPET PANEL

(HORIZONTALLY LAID)

0.5mm COIL COATED CUT

EDGE PROTECTION FLASHING

CUT END COVER FLASHING

SEE ROOF DETAILS FOR

GUTTER DETAILING

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PARAPET GUTTER

22.12.15 -

AWP_HS_16 1:5 1 of 1 A4

-

AWP WALL PARAPET GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_16, 8/12/2016 10:37:51 a.m

.

Page 48

Page 49: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

6 m

in

KINGSPAN KS1000 RW

ROOFING PANEL

CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

"Z" FLASHING WITH CONTINUOUS RUNS OF

6X4mm BUTYL SEALANT. FIX WITH

STITCHING SCREWS OR SEALED RIVETS

FIX TO CUT PANELS AT 500mm CTRs

KINGSPAN KS1000 AWP PANEL

HORIZONTALLY LAID

FILL GAPS WITH FR FOAM FILLER

INTERNAL CLOSER FLASHING

WITH 150MM SEALED

OVERLAP OR BUTT-STRAPS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PARAPET VERGE

22.12.15 -

AWP_HS_17 1:3 1 of 1 A4

-

AWP WALL PARAPET VERGE

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_17, 8/12/2016 10:37:52 a.m

.

Page 49

Page 50: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

6 m

in

0.5mm COIL COATED VERGE FLASHING

CONTINUOUS RUN OF 6x4mm BUTYL SEALANT

INTERNAL CLOSER FLASHING

"Z" FLASHING WITH CONTINUOUS RUNS OF

6x4mm BUTYL SEALANT. FIX WITH STITCHING

SCREWS OR SEALED RIVETS

AWP PANEL BEARER

FILL GAPS WITH PIR

FOAM BLOCK

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

5

1

0

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

PARAPET VERGE WITH PANEL BEARER

22.12.15 -

AWP_HS_18 1:3 1 of 1 A4

-

PARAPET VERGE WITH PANEL BEARER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_18, 8/12/2016 10:37:53 a.m

.

Page 50

Page 51: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

"Z" FLASHING WITH CONTINUOUS

RUNS OF 6x4mm BUTYL SEALANT

0.5mm COIL COATED VERGE FLASHING WITH

150mm SEALED OVERLAP OR BUTT-STRAPS

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

KINGSPAN KS1000 AWP

PANEL HORIZONTALLY LAID

CONTINUOUS RUN OF 6x4mm

BUTYL SEALANT

CONTINUOUS WELDED STEEL FIXING

PLATE BY STEEL CONTRACTOR

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL VERGE DETAIL (RW MALE EDGE)

22.12.15 -

AWP_HS_19 1:3 1 of 1 A4

-

AWP WALL VERGE DETAIL (RW MALE EDGE)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_19, 8/12/2016 10:37:53 a.m

.

Page 51

Page 52: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

CONTINUOUS RUN OF

6x4mm BUTYL SEALANT

"Z" FLASHING WITH CONTINUOUS RUNS OF

6x4mm BUTYL SEALANT . FIX WITH STITCHING

SCREWS OR SEALED RIVETS

CONTINUOUS WELDED STEEL FIXING

PLATE BY STEEL CONTRACTOR

KINGSPAN KS1000 AWP

PANEL HORIZONTALLY LAID

FILL GAPS WITH PIR

FOAM BLOCK.

0.5mm COIL COATED VERGE

FLASHING WITH 150mm SEALED

OVERLAP OR BUTT-STRAPS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL VERGE DETAIL (RW FEMALE EDGE)

22.12.15 -

AWP_HS_20 1:3 1 of 1 A4

-

AWP WALL VERGE DETAIL (RW FEMALE EDGE)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_20, 8/12/2016 10:37:54 a.m

.

Page 52

Page 53: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KS1000 AWP PARAPET PANEL HORIZONTALY LAID

FOAM RIDGE FILLER SEALED TOP &

BOTTOM WITH NON SETTING SEALANT

INTERNAL FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS

FILL GAPS WITH FR

FOAM FILLER

KINGSPAN KS1000 RW ROOFING PANEL

0.5mm COIL COATED APRON FLASHING WITH

150mm SEALED OVERLAP OR BUTT-STRAPS

AWP PANEL

BEARER

FIXING AT PAN

SITE APPLIED GUN GRADE SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL SKILLION DETAIL (PANEL

BEARER)

22.12.15 -

AWP_HS_21 1:3 1 of 1 A4

-

AWP WALL SKILLION DETAIL (PANEL BEARER)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_21, 8/12/2016 10:37:55 a.m

.

Page 53

Page 54: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED DRIP FLASHING SEALED TO

FACE OF PANEL WITH 6x4mm BUTYL SEALANT

KS1000 AWP PANEL

HORIZONTALLY LAID

AWP PANEL BEARER 1500 MAX CTRS

CONTINUOUS GALV SUPPORT ANGLE

AWP JOINT FILLER AND GUN GRADE

SEALANT TO MALE JOINT

FIRE RATED CANISTER INSULATION

APPLIED AS PANEL IS PLACED

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

KS1000 AWP WALL HORIZONTAL TO

VERTICAL STACK JOINT DETAIL

(PANEL BEARER)

22.12.15 -

AWP_HS_22 1:5 1 of 1 A4

-

KS1000 AWP WALL HORIZONTAL TO VERTICAL

STACK JOINT DETAIL (PANEL BEARER)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_22, 8/12/2016 10:37:56 a.m

.

Page 54

Page 55: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

MINERAL FIBRE INSULATION

AWP JOINT FILLER AND GUN GRADE

SEALANT TO MALE JOINT

SEISMIC FLASHING

6x4mm BUTYL SEALANT *

6x4mm BUTYL SEALANT

INTERNAL EXPANSION JOINT

FLASHING WITH 100MM LAPS

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

KS1000 AWP WALL SEISMIC JOINT DETAIL

26.08.16 1

AWP_HS_22 a 1:2 1 of 1 A4

-

KS1000 AWP WALL SEISMIC JOINT DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_22 a, 8/12/2016 10:37:56 a.m

.

Page 55

Page 56: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

(1)

(2)

RUN OF NEUTRAL CURE GUN GRADE SEALANT

INTEGRATED WINDOW FRAME

KS1000 AWP PANEL HORIZONTALLY LAID

DRAINAGE

INTEGRATED WINDOW HEAD EXTRUSION

SEAL AT ENDS TO MAINTAIN

CONTIUITY OF AIR SEAL

FIRE RATED CANISTER INSULATION

1

1

2

2

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL: INTEGRATED HORIZONTAL

WINDOW DETAIL - 50mm ONLY

(VERTICAL SECTION)

22.12.15 -

AWP_HS_23 1:5 1 of 1 A4

-

AWP WALL: INTEGRATED HORIZONTAL WINDOW DETAIL - 50MM ONLY

(VERTICAL SECTION)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_23, 8/12/2016 10:37:57 a.m

.

Page 56

Page 57: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

1

1

2

2

3

3

4

4

(3)

INTEGRATED WINDOW UNIT

(by Others)

WINDOW JAMB FRAME

AWP JOINT FILLER AND GUN

GRADE SEALANT

FOLDED STEEL TOP HAT FLASHING (TOP-HAT A)

6x4mm BUTYL SEALANT *

SNAP-ON COVER FLASHING

(FLUSH)

FILL GAPS WITH PIR FOAM

BLOCKS

FULL LENGTH BUBBLE GASKET

KS1000 AWP WALL PANEL

HORIZONTALLY LAID

(4)

AWP JOINT FILLER AND GUN GRADE

SEALANT

ALUMINUM T SECTION FIXED TO JOINERY. RAIN

DIVERTOR FASHING FIXED TO PANEL ABOVE

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PANEL: INTEGRATED

HORIZONTAL WINDOW SECTION DETAIL

- 50mm ONLY

22.12.15 -

AWP_HS_23a NTS 1 of 1 A4

-

AWP WALL PANEL: INTEGRATED HORIZONTAL WINDOW SECTION DETAIL - 50MM ONLY

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_23a, 8/12/2016 10:37:58 a.m

.

Page 57

Page 58: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

DIM

EN

SIO

N A

S R

EQ

UIR

ED

RIVET FIX

COVER STRIP TO CONCEAL SITE CUT PANEL EDGE IF

REQUIRED (CUT BACK TO SHOW FLAT HEAD FASTENER)

DRIP FLASHING

FLAT HEAD FASTENER - FIX TO

STRUCTURE @ 500MM CENTRES

SITE CUT PANEL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

SITE CUT PANEL DETAIL

22.12.15 -

AWP_HS_24 NTS 1 of 1 A4

-

SITE CUT PANEL DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_24, 8/12/2016 10:37:58 a.m

.

Page 58

Page 59: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

0.5mm COIL COATED SILL FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

WINDOW SUPPORT

FRAME

WINDOW UNIT BY OTHERS

0.5mm COIL COATED HEAD FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

PF BACKING ROD WITH GUN GRADE

SEALANT. BY WINDOW INSTALLER

KS1000 AWP PANEL HORIZONTALLY LAID

KINGSPAN AWP BASE CHANNEL

SUPPORTED ON GALV LEDGER ANGLE

AIR SEAL WITH 6x4mm BUTYL

SEALANT

6 m

in

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL WINDOW DETAIL (Base

Channel)

22.12.15 -

AWP_HS_25 1:2 1 of 1 A4

-

AWP WALL WINDOW DETAIL (BASE CHANNEL)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_25, 8/12/2016 10:37:59 a.m

.

Page 59

Page 60: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

WINDOW UNIT BY OTHERS

WINDOW JAMB FRAME

PF BACKING ROD WITH GUN GRADE

SEALANT. BY WINDOW INSTALLER

KS1000 AWP WALL PANEL HORIZONTALLY LAID

0.5mm COIL COATED JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT *

Note:

Where flashings cross the WV (Wave)

profile use 9 x 6mm thick PVC foam -

Not 6x4mm diameter butyl rubber sealant

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL WINDOW DETAIL

(horizontal section)

26.08.16 1

AWP_HS_25a 1:2 1 of 1 A4

-

AWP WALL WINDOW DETAIL (HORIZONTAL SECTION)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_25a, 8/12/2016 10:38:00 a.m

.

Page 60

Page 61: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

6 m

in

AWP PANEL BEARER 1500 MAX CTRS

0.5mm COIL COATED HEAD FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

PF BACKING ROD WITH GUN GRADE

SEALANT. BY DOOR INSTALLER

DOOR UNIT BY OTHERS

DOOR UNIT BY OTHERS

PF BACKING ROD WITH GUN GRADE

SEALANT. BY WINDOW INSTALLER

KS1000 AWP WALL PANEL

HORIZONTALLY LAID

0.5mm COIL COATED JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PERSONNEL DOOR

DETAIL (PANEL BEARER)

22.12.15 -

AWP_HS_26 1:5 1 of 1 A4

-

AWP WALL PERSONNEL DOOR DETAIL (PANEL BEARER)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_26, 8/12/2016 10:38:01 a.m

.

Page 61

Page 62: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

6 m

in

DOOR HEAD SUPPORT

FRAME

STRUCTURAL DOOR POST

AWP PANEL BEARER

1500 MAX CTRS

0.5mm COIL COATED HEAD

FLASHING SEALED WITH

6x4mm BUTYL SEALANT

0.5mm COIL COATED SOFFIT FLASHING

0.5mm COIL COATED 2 PART JAMB FLASHING

SEALED WITH 6x4mm BUTYL SEALANT

DOOR BY OTHERS

STRUCTURAL DOOR JAMB BY OTHERS

AWP JOINT FILLER AND

GUN GRADE SEALANT

KS1000 AWP PANEL

HORIZONTALLY LAID

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL OVER HEAD DOOR DETAIL

(Panel Bearer)

22.12.15 -

AWP_HS_27 1:5 1 of 1 A4

-

AWP WALL OVER HEAD DOOR DETAIL (PANEL BEARER)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_27, 8/12/2016 10:38:02 a.m

.

Page 62

Page 63: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KINGSPAN AWP 50mm PANEL

AWP JOINT FILLER AND GUN

GRADE SEALANT TO MALE JOINT

FOLDED STEEL TOP HAT

FLASHING

6x4mm BUTYL SEALANT

SNAP-ON COVER FLASHING

(FLUSH)

OUTSIDE FACE OF INTEGRAL

LOUVRE

6x4mm BUTYL SEALANT

LOUVRE BY OTHERS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL INTEGRATED LOUVRE

DETAIL

22.12.15 -

AWP_HS_28 1:5 1 of 1 A4

-

AWP WALL INTEGRATED LOUVRE DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_28, 8/12/2016 10:38:02 a.m

.

Page 63

Page 64: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

HOLE SITE CUT TO ACCOMMODATE

PIPE/DUCTING ETC

INTERNAL COVER FLASHING SEALED WITH

6x4mm BUTYL SEALANT

ALTERNATIVE STANDARD

TEMPERATURE

SITE APPLIED

NON-COMBUSTIBLE INSULATION

PROPRIETARY INSITU WEATHERING SYSTEM

BONDED TO PANELS EXTERNAL SHEET,

COLOUR TO MATCH EXTERNAL PANEL.

PIPE/DUCTING

KS1000 AWP INSULATED WALL

PANEL (HORIZONTALLY LAID)

HIGH TEMPERATURE

Max Unsupported Circular

Penetration - 300mm

SITE APPLIED NON-COMBUSTIBLE

INSULATION

HOLE SITE CUT TO ACCOMMODATE PIPE/DUCTING

ETC. LINE WITH GALVANISED SOAKER.

"DEKTITE" FLEXIBLE PIPE FLASHING OR

SIMILAR TO SUIT CONDITIONS. (to 115° max)

PIPE/DUCTING

KS1000 AWP INSULATED WALL

PANEL (HORIZONTALLY LAID)

INTERNAL COVER FLASHING SEALED

WITH 6x4mm BUTYL SEALANT

STANDARD TEMPERATURE

INTERNAL COVER FLASHING SEALED WITH

6x4mm BUTYL SEALANT

"DEKTITE" FLEXIBLE PIPE FLASHING OR

SIMILAR TO SUIT CONDITIONS.

PIPE/DUCTING

KS1000 AWP INSULATED WALL

PANEL (HORIZONTALLY LAID)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PENETRATION DETAIL

22.12.15 -

AWP_HS_29 1:5 1 of 1 A4

-

AWP WALL PENETRATION DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_29, 8/12/2016 10:38:03 a.m

.

Page 64

Page 65: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

KS1000 AWP BASE CHANNEL DETAILS

NOTE : ABOVE DIMENSIONS ARE THEORETICAL, ACTUAL DIMENSIONS WILL

VARY DUE TO MANUFACTURING TOLERANCES.

ALL DIMENSIONS ABOVE ARE IN MILLIMETERS.

BASE CHANNEL FIXED AT MAX 500mm CENTRES AS SHOWN ABOVE.

BASE CHANNEL TO BE CONTINUOUS AND SILICONE SEALED WHERE

JOINTED.

MATERIAL : 1.6mm THICK GALVANIZED STEEL

Available panel

thicknesses

50 AWP

80 AWP

100 AWP

140 AWP

*DIM A

44m

m

39m

m

7mm

3000mm

PLAN OF CHANNEL AND FIXING

POSITIONS

CROSS SECTION A-A

RELATION WITH PANEL

250mm 500mm 500mm 500mm 500mm 500mm 250mm

Dim "A"

Product

code

21mm

51mm

71mm

111mm

BC 50

BC 80

BC 100

BC 140

A-A

.

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL BASE CHANNEL SUPPORT

DETAIL

22.12.15 -

AWP_HS_30 N.T.S 1 of 1 A4

-

AWP WALL BASE CHANNEL SUPPORT DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_30, 8/12/2016 10:38:04 a.m

.

Page 65

Page 66: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

A-A

.

17

44

.5

1

0

0

°

27

6

KS1000 AWP 50mm

FEMALE JOINT

17

44

.5

1

0

0

°

57

6

SECTION A-A (80mm AWP)

150

9.5

27

.5

12.5

Ø

6

SECTION A-A (50mm AWP)

KINGSPAN 50mm & 80mm AUSTRALIAN

AWP PANEL BEARER DETAILS

ALL DIMENSIONS IN MILLIMETRES

PANEL BEARER FIXING CENTRES 1500 mm MAX

ONE NUMBER PANEL BEARER LOCATED AT EACH END OF PANEL

200

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL PANEL BEARER DETAIL

22.12.15 -

AWP_HS_30a 1:2 1 of 1 A4

-

AWP WALL PANEL BEARER DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_30a, 8/12/2016 10:38:05 a.m

.

Page 66

Page 67: Kingspan KS1000 AWP CodeMark (CM20114) Dteails

FIXING WITH NEO WASHER

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

KS1000 AWP WALL HORIZONTAL_STD Q3 2015

AWP WALL RECESSED WASHER

DETAIL (RECW09G)

22.12.15 -

AWP_HS_31 1:2 1 of 1 A4

-

AWP WALL RECESSED WASHER DETAIL (RECW09G)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\A

WP

W

all H

orizontal\K

S1000 A

WP

W

all H

orizontal_S

td Q

3 2015.dw

g, A

WP

_H

S_31, 8/12/2016 10:38:06 a.m

.