Page 1
BUILDING AND CONSTRUCTION DATA
BUILDING CODE INFORMATION
ADOPTED CODES
INDEX TO DRAWINGS
SHEET DESCRIPTIONTRA
DE
CS COVER SHEET
AR
CH
.
A-1
FLOOR PLANA-2
ME
CH
AN
ICA
L M-1 MECHANICAL PLAN
ELE
CTR
ICA
L E-1 ELECTRICAL PLANS
PLU
MB
ING
P-1 PLUMBING PLAN AND RISER
P-2 GENERAL PLUMBING DETAILS
ENGINEER OF RECORD
KL ENGINEERING INC427 PALM CREST LANELAKE MARY, FLORIDAPHONE: (407) 361-8017
FAX: (407) 250-2559EMAIL: [email protected]
CONTACT PERSON: KHANH LE
FAST FOOD RESTAURANT- ASSEMBLY GROUP A-2OCCUPANCY CLASSIFICATION (FBC 301)
CONSTRUCTION TYPE (FBC TABLE 601)
FIRE RESISTANCE
EXITS - CLASS A
A-FLAMESPREAD 0-25, SMOKE DEV. 0-450
B-FLAMESPREAD 26-75, SMOKE DEV. 0-450
C-FLAMESPREAD 76-200, SMOKE DEV. 0-450
ACCESS - CLASS A
OTHER SPACES - CLASS C
MINIMUM FIRE RESISTANCE, FBC TABLE 705.1.2
FIRE WALLS
TENANT SPACE
HORIZONTAL EXIT
1
2
WALLS
4
3/4
1 1/2
OPENINGS
3
TENANTS SEPARATED BY 1-HOUR
MATERIALS/CONSTRUCTION (FBC 704.4)
SINGLE OCCUPANCY BUILDINGS
OCCUPANCY (BUSINESS)
WITH EXISTING SPRINKLER, TABLE 803.5
INTERIOR FINISHES, FBC 803
CLASSIFICATION, FBC 803.2
TYPE II-B, WITHOUT FIRE SPRINKLER SYSTEM
TOTAL OCCUPANT LOAD = 11 PERSONS LESS THAN 50 PERSON
CLASSIFICATION OF WORKINTERIOR ALTERATION - LEVEL 2
AREA TABULATIONTOTAL AREA = 615 SF
(6 EDITION)
2017 FLORIDA BUILDING CODE, BUILDING
2017 FLORIDA ENERGY CODE
2017 FLORIDA FUEL/GASBCODE
2014 NATIONAL ELECTRICAL CODES
2017 FLORIDA MECHANICAL CODE
2017 FLORIDA BUILDING CODE
2017 FLORIDA FIRE PREVENTION CODE
ACCESSIBILITY:
ENERGY:
FUEL/GAS:
PLUMBING:
MECHANICAL:
ELECTRICAL:
FIRE:
BUILDING:
(W/ LOCAL ADOPTED AMENDMENTS)
2017-FLORIDA ACCESSIBILITY CODE
THEREFORE THIS FACILITY SHALL BE CLASSIFIED AS BUSINESS GROUP B
AS BUILT/ DEMOLITION
A-3 GENERAL DETAILS
E-2 ELECTRICAL PANEL SCHEDULE
CEILING PLAN & LIFE SAFETY PLAN
A-4
A-5
EQUIPMENT PLAN
LIBRARY MAIN
ENTRANCE
LIBRARY AREA
CIR
CU
LA
TIO
N D
ES
K
EXIST. STAIR CASE
EXIST.
EMERGENCY STAIR
CASE
MAIN
ENTRANCE
RECEPTION
ELECTRICAL
ROOM
NEW STAR BUCK
COFFEE SHOP
NEW PATIO
KL
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
KEY PLAN SCALE: 3/16"=1'-0"
Page 2
EXIST. STAIR CASE
EXISTING MEN ADA
BATHROOM
EXISTING WOMEN ADA
BATHROOM
REMOVE EXISTING GLASS PANEL
& DOORS
NEW STARBUCKS AREA
LINE OF NEW
COFFEE SHOP
REMOVE EXISTING GLASS PANEL
FOR NEW 3'0" x 7'0"
GLASS STOREFRONT DOOR
REMOVE EXISTING DOOR.
THEN FILL IN WITH 2-HR
FIRE RATED WALL
REMOVE EXISTING EXTERIOR CMU
WALL FOR NEW
3'0" x 7'0" EGRESS DOOR
PROVIDE 8" D. x 4'-4" LONG
PRECAST HEADER OVER
NEW OPENING. SEE DETAIL
LIMIT OF CONSTRUCTION AREA
CONC. FILLED CELL
W/ (1)#5 VERTICAL
#5 BAR DOWEL TO EXISTING.
MIN. 6" EMBED & 25" LAP
W/ SIMPSON EPOXY ET
EXISTING CMU WALL
EXISTING CMU WALL
INSTALL NEW 8" D. x 4'-4"
PRECAST LINTEL
EXISTING CONC. FOOTING
EXISTING CMU WALL
NEW 8" D. x 4'-4"
PRECAST LINTEL
L 3-1/2 X 3 -1/2" X 3/16" CONT. LEDGER
W/ 3/8" x 6" @ 12" O.C PRECAST LINTEL
RE-INSTALL BRICK VENEER
TO MATCH WITH EXISTING
NEW EXTERIOR DOOR BELOW
EXISTING BRICK VENEER
LIBRARY MAIN ENTRANCE
LIBRARY - READING AREA
CIR
CU
LA
TIO
N D
ES
K
EXIST. STAIR CASE
EXIST. STAIR CASE
MEN BATH
MAIN
ENTRANCE
RECEPTION
NEW STARBUCKS AREA
LINE OF NEW
COFFEE SHOP
LIM
IT
O
F C
ON
ST
RU
CT
IO
N A
RE
A
WOMEN
BATH
EX
IS
T. G
LA
SS
P
AN
EL
KL
AS BUILT/ DEMOLITION PLAN SCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
N
A L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
KEY PLAN SCALE: 1/8"=1'-0"
Page 3
EXIST. EXTERIOR GLASS WALL
EX
IS
T. E
XT
ER
IO
R G
LA
SS
P
AN
EL
COUNTER - 34"H.
EXTERIOR CMU WALL
EXIST. STAIR CASE
EXISTING ADA
BATHROOMS
TO REMAIN
NE
W G
LA
SS
S
TO
RE
F
RO
NT
DINING AREA
FL - 2
W - 2
CL - 1
PREP AREA
F - 1
W - 1
CL - 1
SALE AREA
FL - 1
W - 1
CL - 1
ORDER
PICK
UP
NEW 4" THICK CONCRETE SLAB PATIO
LEVEL WITH BUILDING FINISH FLOOR
TEMPERED FIXED GLASS PANEL
FROM FLOOR TO CEILING
3' H. WALL THEN TEMPERED
FIXED GLASS PANEL
TO CEILING
6" WALL FROM SLAB TO
CEILING ( 6" -20GA METAL
STUD @ 16" O.C)
6" WALL FROM SLAB TO
CEILING ( 6" -20GA METAL
STUD @ 16" O.C)
NOTE:
CONC. SLAB SHALL HAVE MIN. 3000 PSI
COMPRESSIVE STRENGTH AFTER 28 DAYS W/
6x6xW1.4xW1.4 WELDED WIRE MESH PLACED
AT MID DEPTH ON 6 MIL. VAPOR BARRIER ON
4" MIN. TERMITE TREATED COMPACTED FILL
F.F. = 0'-0"
F.F. = 0'-0"
36" H. PRE-ENGINEERED
STL. HANDRAIL
PANIC
HARDWARE
PANIC
HARDWARE
NEW PATIO
F.F. = 0'-0"
F.F. = 0'-0"
F.F. = 0'-0"
F.F. = 0'-0"
3' W. CONCRETE WALKWAY
CONNECT TO EXISTING
WALK WAY
FE
WALL LEGEND
NEW INTERIOR PARTITION WALL (FULL HEIGHT).
SEE FOR DETAIL
EXISTING CMU WALL
NEW 2-HR FIRE RATED WALL (3'4" X 7'0")
SEE FOR DETAIL
FL-1
FINISH SCHEDULE
FLOOR
W-2
WALL
CEILING
FL-2
ALL WALL, FLOOR & CEILING SHALL HAVE FLAME SPREAD INDEX 'C'
NEW 2'x2'
CEILING TILE
9'-3" CLH
CL-1W-1
CERAMIC TILE
CERAMIC TILE PER
CLIENT / CONTRACTOR
PAINT
NEW VINYL TILE PER
CLIENT / CONTRACTOR
NOTE: CONTRACTOR SHALL COORDINATE WITH CLIENT TO CHOOSE FLOOR TILES,
WALL TILE AND CEILING TILES
= 3A-40BC FIRE EXTINGUISHER
(CAPACITY = 5 LB)
SET TOP AT 5 FT. A.F.F.
FE
KL
PROPOSE FLOOR PLAN SCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 4
CEILING LINE
NOTES:
1. USE #7X7/16" PAN HEAD TYPE "S"
FRAMING SCREW FOR STEEL STUD
TO STEEL TRACT.
2. USE #6X1-1/4" TYPE "S" DRYWALL
SCREWS TO STEEL FRAMING.
3. METAL MEMBERS TO BE I ACCORDANCE
WITH THE AISI SPECIFICATIONS FOR THE
DESIGN OF COLD FORMED STRUCTURED
MEMBER, LATEST EDITION.
4. METAL MEMBERS TO BE IN ACCORDANCE
WITH ASTM C645 STANDARD SPECIFICATIONS
FOR NONSTRUCTURAL STEEL FRAMING
MEMBERS 2000
4" x 25 GA. MTL. DIAG. FRM'G AT 48" O.C.
ATTACHED TO STRUCTURE ABOVE
OPTIONAL: TOP TRACT CAN BE
ATTACHED TO CEILING JOIST OR GRID
WITH SCREW @ 24" O.C
METAL CLIP
CEILING LINE
1/2" GYPSUM BOARD
6"-20GA METAL STUD AT 16" O.C.
6" BOTTOM METAL TRACK
3/16"X 1-1/4" MASONRY SCREWS
OR POWDER ACTUATED SCREWS
@ 16" O.C.
CE
IL
IN
G H
EIG
HT
6" METAL TOP TRACK
SCALE: 1/2" = 1'
CASH REGISTER
EXISTING
CONCRETE
HEADER
TOP TRACK
W/ 3 / 16" x 2" TAPCON
TO EXISTING CONC.
HEADER
7'-0"
BOTTOM TRACK W/
ANCHOR @ 32" O/C
4" CONC. SLAB W/ 6X6
10-10 W.W.M.
3/16"X 1-1/4" MASONRY SCREWS
OR POWDER ACTUATED SCREWS
@ 32" O.C.
(2) LAYER OF 5/8" THICK
TYPE 'X' GYPSUM
BOARD ON EACH SIDE
6"-20GA METAL STUD AT 16" O.C.
EXISTING
CMU WALL
SCALE: 1/4" = 1' SCALE: 1/4" = 1'
PARTITION WALL
CEILING LINE
4" x 20 GA. MTL. DIAG. FRM'G AT 24" O.C.
ATTACHED TO STRUCTURE ABOVE
CEILING LINE
4" x 20 GA. MTL. TOP TRACK @ 24" O.C
W/ (2) SCREWS TO EACH BRACING
FIXED GLASS FRAME
FIXED GLASS BELOW
KL
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 5
FE
MAKE
STATION
F.F. = 0'-0"
F.F. = 0'-0"
36" H. PRE-ENGINEERED
STL. HANDRAIL
F.F. = 0'-0"
F.F. = 0'-0"
EQUIPMENT SCHEDULE - WPS STARBUCKS AND FRESHENS SMOOTHIES
MARK QTY DESCRIPTION MANUF / MODEL PROPRIETARY PLUMBING ELECTRICAL
01 1 NON REFRIG / REFRIG MERCHANDISER FEDERAL CD3628/RSS3SCL NA120 VOLT, 16 AMPS
02 1 POS SYSTEM TBD BY SODEXO NA120 VOLT, 10 AMPS
03 2 UNDERCOUNTER REFRIGERATOR TRUE TUC-27LP NA115 VOLT, 2 AMPS
04 1 ESPRESSO MACHINE VERISMO 701 FILTERED WATER208 VOLT, 30 AMPS, L6-30P
05 1 WATER FILTER FOR ESPRESSO TBD 1/2" CW NA
06 1 DIPPERWELL AND FAUCET CECILWARECW, INDIRECT DRAIN TO FLOOR SINK
NA
07 1 SINGLE COFFEE BREWER BUNN THERMOFRESH FILTERED WATER120 / 208 VOLT, 4000 WATTS VERIFY
08 1 WATER FILTER FOR COFFEE BREWER TBD 1/2" COLD WATER NA
09 4 THERMAL COFFEE DISPENSER WITH STAND BUNN 1.5 GAL SHUTTKE NA NA
10A 2 46 INCH DIGITAL MENU SAMSUNG SMART TV OR EQUAL NA120 VOLT, 6 AMPS
10B 1 SMOOTHIE MENU ON THUMB DRIVE FRESHENS MATTINGLY NA NA
10C 1 COFFEE MENU ON THUMB DRIVE TBD BY SODEXO NA NA
11 1 COFFEE RINSE SINK ADVANCE TABCO DI-14-10
COLD WATER, HOT WATER, INDIRECT
WASTE TO FLOOR SINK WITH AIR GAP
NA
12 2 DIPPERWELL NEMCO
COLD WATER, INDIRECT WASTE TO
FLOOR SINK WITH AIR GAP,
NA
13 2 ICE CADDIE CAMBRO NA NA
14 1 FRAP BLENDER VITAMIX MODEL 36019 NA120 VOLT, 15 AMPS
15 1 TEA BREWER BNN TB3 FILTERED WATER120 VOLT, 14.4 AMPS
16 1 WATER FILTER FOR TEA BREWER TBD 1/2" COLD WATER NA
17 1 HAND SINK ADVANCE TABCO 7-PS-60COLD WATER, HOT WATER, WASTE, VENT
NA
18 1 REFRIGERATED COLD PAN
ATLAS WCMD-C-3FY (REPLACE
T-STATE WITH SWITCH)
DRAIN WITH VALVE FOR PERIODIC
CLEANING, PIPE TO FLOOR SINK
120 VOLT, 3.9 AMPS
19 2 WALL SHELVES ADVANCE TABCO WS-12-48 NA NA
20 2 BLENDERS HAMILTON BEACH MATTINGLY NA120 VOLT, 10 AMPS
21 1 SMOOTHIE RINSE SINK ADVANCE TABCO DI-1-10
COLD WATER, HOT WATER, INDIRECT
WASTE TO FLOOR SINK WITH AIR GAP
NA
22 1 BLENDER RINSER HAMILTON BEACH BCR-100 MATTINGLY
COLD WATER ON APPROVED BACK FLOW
PREVENTOR, DECK MOUNTED WASHING
MACHINE VALVE INCLUDED
NA
23 1 REACH IN FREEZER TRUE T-23F NA120 VOLT, 7.2 AMPS
24 1 ICE MAKER HOSHIZAKI KM650MAHCW, INDIRECT DRAIN TO FLOOR SINK 208 VOLT, 1 PH, 7.2 AMPS
25 1 ICE BIN HOSHIZAKI B-300 INDIRECT DRAIN TO FLOOR SINK NA
26 1 MOP SINK ADVANCE TABCO 9-OP-20COLD WATER, HOT WATER, WASTE, VENT
NA
27 1 THREE COMPARTMENT SINK ADVANCE TABCO FC-3-1620-18RL
COLD WATER, HOT WATER,ON APPROVED
GREASE INTERCEPTOR IF REQUIRED
NA
28 1 WALL SHELF ADVANCE TABCO WS-12-84 NA NA
29 1 WALL SHELF ADVANCE TABCO WS-15-84 NA NA
30 1 REACH IN REFRIGERATOR TRUE T-49 NA120 VOLT, 5.8 AMPS
31 1 ILLUMINATED SMOOTHIE SIGN
SOUTHEASTERN (INCLUDES INSTALL)
MATTINGLY NA120 VOLT, 6 AMPS
32 1 WPS STARBUCKS SIGN STARBUCKS NA NA
33 1 ELECTRIC TANKLESS WATER HEATER MINI120 VOLT, 21 AMPS, 2.4 KWCOLD WATER, HOT WATER,
KL
EQUIPMENT PLAN SCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
N
A L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
N
A L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 6
EM
EGRESS
DISTANCE 43'
EGRESS
DISTANCE 43'
FE
TO EXISTING BUILDING MAIN ENTRANCE
A
R
A
R
NEW 2' x 2' CEILING
TILE
9'-3" A.F.F.
EM
2'x2' RETURN AIR DIFFUSER
TYPE
2'x2' AIR SUPPLY DIFFUSER
A
R
EM
EXIT- EM
EMERGENCY & EXIT LIGHT COMBO
EMERGENCY LIGHT
EXIT LIGHT
SYMBOL
RECESSED LIGHT FIXTURE
PENDENT LIGHT
#9 WIRE
HANGERS AT
4'-0" O.C. DECK
ABOVE
STEEL FRAME ABOVE
2'x2' CEILING TILE
KL
LIFE SAFETY PLAN SCALE: 1/4"=1'-0"
REFLECTED CEILING PLAN SCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
N
A L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 7
CL
S - 3
S - 5
GFI
S - 7
S - 9
S - 11, 13
GFI
GFI
S - 15, 17
GFI
8'0" AFF.
S - 3
S - 4
S - 6
GFI
GFI
S - 2
GFI
8'0" AFF.
S - 8
S - 10
S - 12
GFI
GFI
GFI
S - 14
GFI
S - 16
GFI
S - 18
GFI
ELECT. PANEL - S
125 AMP, 3 PHASES
S - 19,21
NEW 2 TON A/C
MINI SPLIT SYSTEM
ON CEILING
S - 20,22
EM
S - 1
S - 1
EXIT
EXIT
EX
IT
CONNECT TO EXISTING
LOCAL LIGHTING CIRCUIT
CONNECT TO EXISTING
LOCAL LIGHTING CIRCUIT
1.) ASSURE ALL EXITING 120 VOLT BRANCH CIRCUIT FOR EMERGENCY WHITE
LIGHTING BATTERY PACK AND BACK UP OPERATED EXIT LIGHT. ALL
BATTERY OPERATED EXIT LIGHTS AND EMERGENCY WHITE LIGHTS SHALL
HAVE CAPACITY TO OPERATE FOR MINIMUM OF 90 MINUTES.
2.) ASSURE ALL EXISTING EMERGENCY AND EXIT LIGHTINGS TO CONNECT TO
LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHES.
SYMBOL LAMPSVOLTTYPE
EMERGENCY LIGHT - ELM2 N
EM
GENERAL NOTES:
120
EX120
1. EXIT SIGN-RED LETTERS, WHITE FINISH, BATT. PACK LIGHTOLIER #LLC2URW WITH EMER. FLOODS.
EMERGENCY LIGHTING - LIGHTOLIER #E5W (2-5.4w) TWIN LIGHT/BATTERY BACK-UP. WALL
MOUNTED, WHITE FINISH. MOUNT @ 108"AFF
DECORATIVE GLASS PENDANT
EXIT LIGHT LED INCLUDED
LED INCLUDED
RECESSED LED LIGHT FIXTURE
120
REMARK
120
EXIT- EM
EMERGENCY & EXIT LIGHT COMBO
AUTOMATIC WALL SWITCH WITH BUILT IN LIGHT LEVEL SENSOR
SIMILAR TO WATTSTOPPER WI-200 MODEL
9 WATT
EM
ALL ELECTRICAL DESIGN AND INSTALLATION
SHALL COMPLY WITH 2014 NEC
WALL SWITCH (1-WAY)
SINGLE OUTLET
S.P.S.T.
220 VOLTS
THERMOSTAT
WALL SWITCH (3-WAY)
TELEPHONE OUTLET PREWIRE
DATA OUTLET
QUAD OUTLET 120 VOLTS
ELECTRICAL LEGEND
DESCRIPTION
SYMBOL
REMARKS
TV CABLE
TV
DUPLEX OUTLET 120 VOLTS
LED RECESS LIGHT
EMERGENCY LIGHT
EXIT LIGHT
WALL SCONE LIGHT
EXIT- EM
EXIT & EMERGENCY LIGHT
COMBO
J - BOX
GENERAL NOTES:
= AUTOMATIC WALL SWITCH WITH BUILT IN LIGHT LEVEL
SENSOR SIMILAR TO WATTSTOPPER WI-200 MODEL
PENDANT LIGHT
DISCONNECT SWITCH
EXIT
KL
KL
ELECTRICAL POWER PLAN SCALE: 1/4"=1'-0"
LIGHTING PLAN SCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
N
A L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 8
LIBRARY MAIN
ENTRANCE
LIBRARY AREA
CIR
CU
LA
TIO
N D
ES
K
EXIST. STAIR CASE
EXIST.
EMERGENCY STAIR
CASE
MAIN
ENTRANCE
RECEPTION
ELECTRICAL
ROOM
NEW COFFEE
SHOP
NEW PATIO
BUILDING MAIN
BREAKER 'MBR'
R
U
N
1
.
5
"
C
O
N
D
U
I
T
A
B
O
V
E
C
E
I
L
I
N
G
PANEL 'S'
'MCB'
3PH,4W120/208V
BREAKER
EXISTING MAIN
TO XFMER
EXISTING
POWER RISER DIAGRAM
1200A
EXISTING WIREWAY
EXIST.
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
NEW MCBPANEL S - 125A
ELECTRICAL ROOM
EXIST. EXIST. EXIST.
APPROXIMATE 132 FT
FEEDER SIZES
(1) SET - (4) #2/0 Cu, (1) #2/0G. IN 1.5" CONDUIT
KL
KL
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 9
VENTILATION REQUIRED (CFM) CALCULATION
No OF PEOPLE = 12
TABLE 403.3 FMC-2010
PEOPLE OUTDOOR AIRFLOW RATE IN
BREATHING ZONE, Rp CFM/PERSON
7.5 CFM/ PERSON
VENTILATION AIR REQUIRED
Vz = RpxPz = 90 CFM
Pz = 12
TOTAL REQUIRED = 90 CFM
TOTAL PROVIDE = 100 CFM = OK ( PROVIDED BY EF-1 )
DINING & PREP AREA
REFERENCE NOTES
KEEP EXISTING AIR SUPPLY / RETURN GRILL
1
INSTALL 24" x 24" AIR BY PASS GRILL WITH 10"Ø FLEX DUCT
INSTALL NEW 2 TON A/C MINI SPLIT SYSTEM
2
3
HVAC LEGEND
EXISTING 2'x2' RETURN AIR DIFFUSER
EXISTING 2'x2' AIR SUPPLY DIFFUSER
A
R
BY PASS AIR RETURN FLEX DUCT
(SIZE IS SHOWN ON PLAN)
4INSTALL EXHAUST FAN EF-1 WITH CAPACITY OF 100 CFM FOR
VENTILATION
EXHAUST FAN FOR VENTILATION.
PROVIDE 100 CFM
NEW 2 TON A/C MINI SPLIT SYSTEM
MOUNT ON CEILING
5MOUNT NEW A/C CU ON THE EXTERIOR WALL
A
R
A
R
EXIST.
NEW NEW
12"Ø BY
PASS
HVAC NOTES:
THIS COFFEE SHOP IS LOCATED INSIDE LIBRARY.
THEN THEY ARE SHARING EXISTING HVAC SYSTEM.
EXIST.
EXIST.
150
CFM
150
CFM
100
CFM
NEW 2 TON A/C
MINI SPLIT SYSTEM
ON CEILING
1
1
1
A
R
2 2
3
4
5
SEAL PENETRATION
EXTERIOR WALL
SEALAND ALL AROUND
SHEET METAL BOX TO BE 1-1/2" MIN.
LARGER THAN SLEEVE
BACKDRAFT DAMPER FOR DRYER ONLY
CONTRACTOR TO PAINT W/
WEATHER RESISTANT PAINT
COLOR TO BE COORD. / ARCH/ OWNER
SEALANT ALL AROUND
EXTERIOR WALL PENETRATION DETAIL FORDRYER DUCT VENT
6" DIA. SHEET METAL
DUCT SLEEVE FOR
DRYER VENT
A/C HANGING
BRACKET (ADJUSTABLE)
W/ NUT AND WASHER AT
EACH END ( TOTAL OF 4 RODS )
3/8" ALL THREADED ROD
EXIST. 8" CMU BLOCK
MINI CU
2" x 2" STEELANGLE FRAMETOTAL OF 2
SCALE: N.T.S.THIS DESIGN FOR 160 MPH WIND LOAD
12" CONCRETE LUG BOLTS
KL
KL
FLOOR PLAN - HVACSCALE: 1/4"=1'-0"
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 10
3/4" C
3/4" C
CONNECT TO EXISTING
COLD WATER SUPPLY.
FIELD TO VERIFY
LOCATION
1/2" H & C
1/2" C
1/2" C
1/2" C
1/2" C
1/2" H & C
1/2" C
1/2" H & C
1/2" C
1/2" C
1/2" H & C
1/2" H & C
3/4" H
&
C
1/2" C
TANKLESS WATER
HEATER ON WALL
3/4" H & C
1/2" C
3/4" H
&
C
1. VERIFY ALL EXISTING CONDITIONS AND EXACT
LOCATIONS OF ALL EQUIPMENT TO BE PLUMBED PRIOR TO
THE COMMENCEMENT OF WORK. COORDINATE ALL
WORK WITH ALL TRADES.
2. COMPLETE AND WORKING PLUMBING SYSTEMS SHALL BE
IN ACCORDANCE WITH THE 2017 FLORIDA PLUMBING
CODE AND LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
3. PRESSURE AND HYDROSTATICALLY TEST THE PIPING, AS
APPLICABLE, TO INSURE THE ABSENCE OF LEAKS IN
ACCORDANCE WITH THE 2017 FPC
BUILDING/PLUMBING CODE. DISINFECT ALL DOMESTIC
WATER PIPING IN ACCORDANCE WITH THE 2017 FLORIDA
BUILDING/PLUMBING CODE.
4. NEW WASTE DRAIN AND VENT PIPING SHALL BE PVC DWV
TRENCHES SHALL BE BACKFILLED AND COMPACTED.
NEW CW AND HW PIPING SHALL BE CPVC PIPING EQUAL
TO FLO GUARD GOLD. WRAP NEW HOT WATER PIPING WITH
1" R-4 PER INCH (PER THE 2017 FLORIDA MODEL ENERGY
CODE) CELLULAR RUBBER INSULATION EQUAL TO
ARMSTRONG ARMAFLEX. NOTE: BRANCH PIPING LESS
THAN 12' MAY BE INSULATED WITH 1/2" INSULATION PER
SAME CODE.
5. SECURE ALL REQUIRED PERMITS AND PAY ALL
ASSOCIATED FEES.
3 - COMPARTMENT SINK (18"L x18"W x12"D)
CUBIC CONTENT = 3 x (18" x 18" x 12") = 11,664 IN³
MOP SINK (18"L x 24"W x 12"D)
CUBIC CONTENT = ( 18" x 24" x 12" ) = 5,184 IN³
HAND SINK (12"L x 12"W x 8"D)
CUBIC CONTENT = 1 X (12" x 12" x 8") = 1,152 IN ³
RINSE SINK (12"L x 12"W x 8"D)
CUBIC CONTENT = 2 X (12" x 12" x 8") = 2 x 1,152 = 2,304 IN ³
TOTAL CUBIC CONTENT = 11,664 + 5,184 + 1,152 + 2,304 = 20,304 IN ³
20,304 IN³ / (231 IN³/GAL) = 87.89 GAL.
FLOW FACTOR = 1
ACTUAL DRAINAGE LOAD = 1 x 87.89 = 87.89 GMP FLOW RATE
REQUIRED GREASE TRAP CAPACITY 87.89 GMP
PROVIDE GREASE TRAP CAPACITY OF 100 GMP = OK
1.5" V
FS-1
2"
FS-1
2"
FS-1
2"
2"
H.S
FS-1
3"
M.S
2"
3"
FS-1
2"
FD-1
FS-1
2"
FS-1
2"
3"
3"
3"
2"
3"
CONNECT TO EXISTING
SANITARY LINE.
FIELD TO VERIFY LOCATION
1.5" V
1.5" V
1.5" V
1.5" V
1.5" V
1.5" V
1.5" V
2" STUDOR
VENT TO OUTSIDE WALL
3
"
V
.
2
"
V
.
2
"
V
.
100 GAL
GREASE TRAP
BELOW SLAB
N
E
W
3
"
Ø
S
A
N
I
T
A
R
Y
L
I
N
E
N
E
W
3
"
Ø
G
R
E
A
S
E
L
I
N
E
3"
NEW 4" THICK. CONC. SLAB MIN. 3000 PSI
COMPRESSIVE STRENGTH AFTER 28 DAYS W/
6x6xW1.4xW1.4 WELDED WIRE MESH PLACED AT MID
DEPTH ON 6 MIL. VAPOR BARRIER ON 4" MIN. TERMITE
TREATED COMPACTED FILL
EXISTING CONC. SLAB
TYPICAL CONCRETE SLAB REPAIR
#4 DOWEL 4" EMBED TO EXISTING
CONC. SLAB & 10" LAP TO NEW CONCRETE
SLAB AT SPACING OF 48" O.C.
WITH SIMPSON EPOXY ET
NOTE: IF THE WIDTH OF TRENCH IS LESS THAN
16", DOWEL SHALL NOT BE REQUIRED
3
/
4
"
H
&
C
3
/
4
"
C
CONNECT TO EXISTING
COLD WATER SUPPLY.
FIELD TO VERIFY LOCATION
3
/
4
"
H
&
C
MS
1/2
" H
&
C
3-COMP
1/2
" H
&
C
ICE M.
1
/
2
"
C
BL.R.
SM.R.SINK
1
/
2
"
H
&
C
PROVIDE BACK FLOW PREVENTOR,
DECK MOUNTED WASHING MACHINE
VALVE INCLUDED
HS
1
/
2
"
H
&
C
1
/
2
"
H
&
C
1
/
2
"
C
1
/
2
"
C
1
/
2
"
C
3
/
4
"
C
1/2
" C
1/2
" C
W.F.
DIP.&FAUCET
3
/
4
"
C
SHUT OFF VALE
1
/
2
"
C
1
/
2
"
C
DIP.
W.F.
DIP.
COF.R.SINK
W.F.
3
/
4
"
C
TANKLESS
WH.
3
/
4
"
H
&
C
2"
2"
3" FD-1
2"
2"
2"
2"
3"
3"
2"
2"
3"
CUT 12" W. CONCRETE TRENCH FOR
SANITARY PLUMBING PIPE.
AFTER PLUMBING WORK DONE, POUR 4"
THICK. CONC. SLAB WITH 3000 PSI
CONCRETE WITH WIRE MESH. PROVIDE
THERMAL TREATED FOR SOIL AND
VAPOR BARRIER PRIOR TO POUR NEW
CONC. SLAB
3"
NEW 3"Ø SANITARY LINE
NEW 3"Ø GREASE LINE
100 GAL
GREASE TRAP
BELOW GROUND
CONNECT TO EXISTING
SANITARY LINE.
FIELD TO VERIFY LOCATION
COLD WATER ( C-PVC SIZE SHOWN ON PLAN )
HOT WATER ( C-PVC SIZE SHOWN ON PLAN )
C
H
SAN
SANITARY LINE ( C-PVC SIZE SHONW ON PLAN )
GREASE
GREASE LINE ( C-PVC SIZE SHONW ON PLAN )
FLOOR SANITARY PLANSCALE: 1/4"=1'-0"
KL
FRESH WATER PIPING PLANSCALE: 1/4"=1'-0"
WATER DIAGRAMDRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ
Page 11
GROUT AROUND
RAISED DRAIN NECK
KL
DRAWING NUMBER
DATE
PROJECT
CAD FILE
CHECKED
DRAWN
BY
5-02-18
DA
TER
EV 1 2
PROFESSIONAL SEAL
427
Palm
Cre
st L
ane
Lake
Mar
y, F
l 327
46Ph
one
(407
) 361
-801
7, e
mai
l: kl
engi
neer
ing1
1@gm
ail.c
om
FLO
RID
A C
.A #
3161
9
Date: 5-02-2018
KL
ENG
INEE
RIN
G
3 4
DES
CR
IPTI
ON
BET
HU
NE
CO
OK
MA
N U
NIV
ERSI
TYLI
BR
AR
YD
ayto
na B
each
, FL
P
R
O
F
E
S
S
I
O
NA L
E
N
G
I
N
E
E
R
K
H
A
N
H
L
E
No. 70935
STATE OF
L
I
C
EN
S
E
F
L
O
R I
D
A
C
O
UQ