BUILDING AND CONSTRUCTION DATA BUILDING CODE INFORMATION ADOPTED CODES INDEX TO DRAWINGS SHEET DESCRIPTION TRADE CS COVER SHEET ARCH. A-1 FLOOR PLAN A-2 MECHANICAL M-1 MECHANICAL PLAN ELECTRICAL E-1 ELECTRICAL PLANS PLUMBING P-1 PLUMBING PLAN AND RISER P-2 GENERAL PLUMBING DETAILS ENGINEER OF RECORD KL ENGINEERING INC 427 PALM CREST LANE LAKE MARY, FLORIDA PHONE: (407) 361-8017 FAX: (407) 250-2559 EMAIL: [email protected] CONTACT PERSON: KHANH LE FAST FOOD RESTAURANT- ASSEMBLY GROUP A-2 OCCUPANCY CLASSIFICATION (FBC 301) CONSTRUCTION TYPE (FBC TABLE 601) FIRE RESISTANCE EXITS - CLASS A A-FLAMESPREAD 0-25, SMOKE DEV. 0-450 B-FLAMESPREAD 26-75, SMOKE DEV. 0-450 C-FLAMESPREAD 76-200, SMOKE DEV. 0-450 ACCESS - CLASS A OTHER SPACES - CLASS C MINIMUM FIRE RESISTANCE, FBC TABLE 705.1.2 FIRE WALLS TENANT SPACE HORIZONTAL EXIT 1 2 WALLS 4 3/4 1 1/2 OPENINGS 3 TENANTS SEPARATED BY 1-HOUR MATERIALS/CONSTRUCTION (FBC 704.4) SINGLE OCCUPANCY BUILDINGS OCCUPANCY (BUSINESS) WITH EXISTING SPRINKLER, TABLE 803.5 INTERIOR FINISHES, FBC 803 CLASSIFICATION, FBC 803.2 TYPE II-B, WITHOUT FIRE SPRINKLER SYSTEM TOTAL OCCUPANT LOAD = 11 PERSONS LESS THAN 50 PERSON CLASSIFICATION OF WORK INTERIOR ALTERATION - LEVEL 2 AREA TABULATION TOTAL AREA = 615 SF (6 EDITION) 2017 FLORIDA BUILDING CODE, BUILDING 2017 FLORIDA ENERGY CODE 2017 FLORIDA FUEL/GASBCODE 2014 NATIONAL ELECTRICAL CODES 2017 FLORIDA MECHANICAL CODE 2017 FLORIDA BUILDING CODE 2017 FLORIDA FIRE PREVENTION CODE ACCESSIBILITY: ENERGY: FUEL/GAS: PLUMBING: MECHANICAL: ELECTRICAL: FIRE: BUILDING: (W/ LOCAL ADOPTED AMENDMENTS) 2017-FLORIDA ACCESSIBILITY CODE THEREFORE THIS FACILITY SHALL BE CLASSIFIED AS BUSINESS GROUP B AS BUILT/ DEMOLITION A-3 GENERAL DETAILS E-2 ELECTRICAL PANEL SCHEDULE CEILING PLAN & LIFE SAFETY PLAN A-4 A-5 EQUIPMENT PLAN LIBRARY MAIN ENTRANCE LIBRARY AREA CIRCULATION DESK EXIST. STAIR CASE EXIST. EMERGENCY STAIR CASE MAIN ENTRANCE RECEPTION ELECTRICAL ROOM NEW STAR BUCK COFFEE SHOP NEW PATIO KL DRAWING NUMBER DATE PROJECT CAD FILE CHECKED DRAWN BY 5-02-18 DATE REV 1 2 PROFESSIONAL SEAL 6Q VJG DGUV QH VJG MPQYNGFIG QH VJG 'PIKPGGT QT #TEJKVGEV VJG RNCPU CPF URGEKHKECVKQPU JGTGKP EQORN[ YKVJ VJG (NQTKFC DWKNFKPI EQFG CPF CTG 5KIPGF CPF 5GCNGF CEEQTFKPIN[ 427 Palm Crest Lane Lake Mary, Fl 32746 Phone (407) 361-8017, email: [email protected] FLORIDA C.A #31619 Date: 5-02-2018 KL ENGINEERING 3 4 DESCRIPTION BETHUNE COOKMAN UNIVERSITY LIBRARY Daytona Beach, FL P R O F E S S I O N A L E N G I N E E R K H A N H L E No. 70935 STATE OF L I C E N S E F L O R I D A C O U Q KEY PLAN SCALE: 3/16"=1'-0"
11

KEY PLAN - Daytona Beach

Apr 24, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: KEY PLAN - Daytona Beach

BUILDING AND CONSTRUCTION DATA

BUILDING CODE INFORMATION

ADOPTED CODES

INDEX TO DRAWINGS

SHEET DESCRIPTIONTRA

DE

CS COVER SHEET

AR

CH

.

A-1

FLOOR PLANA-2

ME

CH

AN

ICA

L M-1 MECHANICAL PLAN

ELE

CTR

ICA

L E-1 ELECTRICAL PLANS

PLU

MB

ING

P-1 PLUMBING PLAN AND RISER

P-2 GENERAL PLUMBING DETAILS

ENGINEER OF RECORD

KL ENGINEERING INC427 PALM CREST LANELAKE MARY, FLORIDAPHONE: (407) 361-8017

FAX: (407) 250-2559EMAIL: [email protected]

CONTACT PERSON: KHANH LE

FAST FOOD RESTAURANT- ASSEMBLY GROUP A-2OCCUPANCY CLASSIFICATION (FBC 301)

CONSTRUCTION TYPE (FBC TABLE 601)

FIRE RESISTANCE

EXITS - CLASS A

A-FLAMESPREAD 0-25, SMOKE DEV. 0-450

B-FLAMESPREAD 26-75, SMOKE DEV. 0-450

C-FLAMESPREAD 76-200, SMOKE DEV. 0-450

ACCESS - CLASS A

OTHER SPACES - CLASS C

MINIMUM FIRE RESISTANCE, FBC TABLE 705.1.2

FIRE WALLS

TENANT SPACE

HORIZONTAL EXIT

1

2

WALLS

4

3/4

1 1/2

OPENINGS

3

TENANTS SEPARATED BY 1-HOUR

MATERIALS/CONSTRUCTION (FBC 704.4)

SINGLE OCCUPANCY BUILDINGS

OCCUPANCY (BUSINESS)

WITH EXISTING SPRINKLER, TABLE 803.5

INTERIOR FINISHES, FBC 803

CLASSIFICATION, FBC 803.2

TYPE II-B, WITHOUT FIRE SPRINKLER SYSTEM

TOTAL OCCUPANT LOAD = 11 PERSONS LESS THAN 50 PERSON

CLASSIFICATION OF WORKINTERIOR ALTERATION - LEVEL 2

AREA TABULATIONTOTAL AREA = 615 SF

(6 EDITION)

2017 FLORIDA BUILDING CODE, BUILDING

2017 FLORIDA ENERGY CODE

2017 FLORIDA FUEL/GASBCODE

2014 NATIONAL ELECTRICAL CODES

2017 FLORIDA MECHANICAL CODE

2017 FLORIDA BUILDING CODE

2017 FLORIDA FIRE PREVENTION CODE

ACCESSIBILITY:

ENERGY:

FUEL/GAS:

PLUMBING:

MECHANICAL:

ELECTRICAL:

FIRE:

BUILDING:

(W/ LOCAL ADOPTED AMENDMENTS)

2017-FLORIDA ACCESSIBILITY CODE

THEREFORE THIS FACILITY SHALL BE CLASSIFIED AS BUSINESS GROUP B

AS BUILT/ DEMOLITION

A-3 GENERAL DETAILS

E-2 ELECTRICAL PANEL SCHEDULE

CEILING PLAN & LIFE SAFETY PLAN

A-4

A-5

EQUIPMENT PLAN

LIBRARY MAIN

ENTRANCE

LIBRARY AREA

CIR

CU

LA

TIO

N D

ES

K

EXIST. STAIR CASE

EXIST.

EMERGENCY STAIR

CASE

MAIN

ENTRANCE

RECEPTION

ELECTRICAL

ROOM

NEW STAR BUCK

COFFEE SHOP

NEW PATIO

KL

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

KEY PLAN SCALE: 3/16"=1'-0"

Page 2: KEY PLAN - Daytona Beach

EXIST. STAIR CASE

EXISTING MEN ADA

BATHROOM

EXISTING WOMEN ADA

BATHROOM

REMOVE EXISTING GLASS PANEL

& DOORS

NEW STARBUCKS AREA

LINE OF NEW

COFFEE SHOP

REMOVE EXISTING GLASS PANEL

FOR NEW 3'0" x 7'0"

GLASS STOREFRONT DOOR

REMOVE EXISTING DOOR.

THEN FILL IN WITH 2-HR

FIRE RATED WALL

REMOVE EXISTING EXTERIOR CMU

WALL FOR NEW

3'0" x 7'0" EGRESS DOOR

PROVIDE 8" D. x 4'-4" LONG

PRECAST HEADER OVER

NEW OPENING. SEE DETAIL

LIMIT OF CONSTRUCTION AREA

CONC. FILLED CELL

W/ (1)#5 VERTICAL

#5 BAR DOWEL TO EXISTING.

MIN. 6" EMBED & 25" LAP

W/ SIMPSON EPOXY ET

EXISTING CMU WALL

EXISTING CMU WALL

INSTALL NEW 8" D. x 4'-4"

PRECAST LINTEL

EXISTING CONC. FOOTING

EXISTING CMU WALL

NEW 8" D. x 4'-4"

PRECAST LINTEL

L 3-1/2 X 3 -1/2" X 3/16" CONT. LEDGER

W/ 3/8" x 6" @ 12" O.C PRECAST LINTEL

RE-INSTALL BRICK VENEER

TO MATCH WITH EXISTING

NEW EXTERIOR DOOR BELOW

EXISTING BRICK VENEER

LIBRARY MAIN ENTRANCE

LIBRARY - READING AREA

CIR

CU

LA

TIO

N D

ES

K

EXIST. STAIR CASE

EXIST. STAIR CASE

MEN BATH

MAIN

ENTRANCE

RECEPTION

NEW STARBUCKS AREA

LINE OF NEW

COFFEE SHOP

LIM

IT

O

F C

ON

ST

RU

CT

IO

N A

RE

A

WOMEN

BATH

EX

IS

T. G

LA

SS

P

AN

EL

KL

AS BUILT/ DEMOLITION PLAN SCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

N

A L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

KEY PLAN SCALE: 1/8"=1'-0"

Page 3: KEY PLAN - Daytona Beach

EXIST. EXTERIOR GLASS WALL

EX

IS

T. E

XT

ER

IO

R G

LA

SS

P

AN

EL

COUNTER - 34"H.

EXTERIOR CMU WALL

EXIST. STAIR CASE

EXISTING ADA

BATHROOMS

TO REMAIN

NE

W G

LA

SS

S

TO

RE

F

RO

NT

DINING AREA

FL - 2

W - 2

CL - 1

PREP AREA

F - 1

W - 1

CL - 1

SALE AREA

FL - 1

W - 1

CL - 1

ORDER

PICK

UP

NEW 4" THICK CONCRETE SLAB PATIO

LEVEL WITH BUILDING FINISH FLOOR

TEMPERED FIXED GLASS PANEL

FROM FLOOR TO CEILING

3' H. WALL THEN TEMPERED

FIXED GLASS PANEL

TO CEILING

6" WALL FROM SLAB TO

CEILING ( 6" -20GA METAL

STUD @ 16" O.C)

6" WALL FROM SLAB TO

CEILING ( 6" -20GA METAL

STUD @ 16" O.C)

NOTE:

CONC. SLAB SHALL HAVE MIN. 3000 PSI

COMPRESSIVE STRENGTH AFTER 28 DAYS W/

6x6xW1.4xW1.4 WELDED WIRE MESH PLACED

AT MID DEPTH ON 6 MIL. VAPOR BARRIER ON

4" MIN. TERMITE TREATED COMPACTED FILL

F.F. = 0'-0"

F.F. = 0'-0"

36" H. PRE-ENGINEERED

STL. HANDRAIL

PANIC

HARDWARE

PANIC

HARDWARE

NEW PATIO

F.F. = 0'-0"

F.F. = 0'-0"

F.F. = 0'-0"

F.F. = 0'-0"

3' W. CONCRETE WALKWAY

CONNECT TO EXISTING

WALK WAY

FE

WALL LEGEND

NEW INTERIOR PARTITION WALL (FULL HEIGHT).

SEE FOR DETAIL

EXISTING CMU WALL

NEW 2-HR FIRE RATED WALL (3'4" X 7'0")

SEE FOR DETAIL

FL-1

FINISH SCHEDULE

FLOOR

W-2

WALL

CEILING

FL-2

ALL WALL, FLOOR & CEILING SHALL HAVE FLAME SPREAD INDEX 'C'

NEW 2'x2'

CEILING TILE

9'-3" CLH

CL-1W-1

CERAMIC TILE

CERAMIC TILE PER

CLIENT / CONTRACTOR

PAINT

NEW VINYL TILE PER

CLIENT / CONTRACTOR

NOTE: CONTRACTOR SHALL COORDINATE WITH CLIENT TO CHOOSE FLOOR TILES,

WALL TILE AND CEILING TILES

= 3A-40BC FIRE EXTINGUISHER

(CAPACITY = 5 LB)

SET TOP AT 5 FT. A.F.F.

FE

KL

PROPOSE FLOOR PLAN SCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 4: KEY PLAN - Daytona Beach

CEILING LINE

NOTES:

1. USE #7X7/16" PAN HEAD TYPE "S"

FRAMING SCREW FOR STEEL STUD

TO STEEL TRACT.

2. USE #6X1-1/4" TYPE "S" DRYWALL

SCREWS TO STEEL FRAMING.

3. METAL MEMBERS TO BE I ACCORDANCE

WITH THE AISI SPECIFICATIONS FOR THE

DESIGN OF COLD FORMED STRUCTURED

MEMBER, LATEST EDITION.

4. METAL MEMBERS TO BE IN ACCORDANCE

WITH ASTM C645 STANDARD SPECIFICATIONS

FOR NONSTRUCTURAL STEEL FRAMING

MEMBERS 2000

4" x 25 GA. MTL. DIAG. FRM'G AT 48" O.C.

ATTACHED TO STRUCTURE ABOVE

OPTIONAL: TOP TRACT CAN BE

ATTACHED TO CEILING JOIST OR GRID

WITH SCREW @ 24" O.C

METAL CLIP

CEILING LINE

1/2" GYPSUM BOARD

6"-20GA METAL STUD AT 16" O.C.

6" BOTTOM METAL TRACK

3/16"X 1-1/4" MASONRY SCREWS

OR POWDER ACTUATED SCREWS

@ 16" O.C.

CE

IL

IN

G H

EIG

HT

6" METAL TOP TRACK

SCALE: 1/2" = 1'

CASH REGISTER

EXISTING

CONCRETE

HEADER

TOP TRACK

W/ 3 / 16" x 2" TAPCON

TO EXISTING CONC.

HEADER

7'-0"

BOTTOM TRACK W/

ANCHOR @ 32" O/C

4" CONC. SLAB W/ 6X6

10-10 W.W.M.

3/16"X 1-1/4" MASONRY SCREWS

OR POWDER ACTUATED SCREWS

@ 32" O.C.

(2) LAYER OF 5/8" THICK

TYPE 'X' GYPSUM

BOARD ON EACH SIDE

6"-20GA METAL STUD AT 16" O.C.

EXISTING

CMU WALL

SCALE: 1/4" = 1' SCALE: 1/4" = 1'

PARTITION WALL

CEILING LINE

4" x 20 GA. MTL. DIAG. FRM'G AT 24" O.C.

ATTACHED TO STRUCTURE ABOVE

CEILING LINE

4" x 20 GA. MTL. TOP TRACK @ 24" O.C

W/ (2) SCREWS TO EACH BRACING

FIXED GLASS FRAME

FIXED GLASS BELOW

KL

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 5: KEY PLAN - Daytona Beach

FE

MAKE

STATION

F.F. = 0'-0"

F.F. = 0'-0"

36" H. PRE-ENGINEERED

STL. HANDRAIL

F.F. = 0'-0"

F.F. = 0'-0"

EQUIPMENT SCHEDULE - WPS STARBUCKS AND FRESHENS SMOOTHIES

MARK QTY DESCRIPTION MANUF / MODEL PROPRIETARY PLUMBING ELECTRICAL

01 1 NON REFRIG / REFRIG MERCHANDISER FEDERAL CD3628/RSS3SCL NA120 VOLT, 16 AMPS

02 1 POS SYSTEM TBD BY SODEXO NA120 VOLT, 10 AMPS

03 2 UNDERCOUNTER REFRIGERATOR TRUE TUC-27LP NA115 VOLT, 2 AMPS

04 1 ESPRESSO MACHINE VERISMO 701 FILTERED WATER208 VOLT, 30 AMPS, L6-30P

05 1 WATER FILTER FOR ESPRESSO TBD 1/2" CW NA

06 1 DIPPERWELL AND FAUCET CECILWARECW, INDIRECT DRAIN TO FLOOR SINK

NA

07 1 SINGLE COFFEE BREWER BUNN THERMOFRESH FILTERED WATER120 / 208 VOLT, 4000 WATTS VERIFY

08 1 WATER FILTER FOR COFFEE BREWER TBD 1/2" COLD WATER NA

09 4 THERMAL COFFEE DISPENSER WITH STAND BUNN 1.5 GAL SHUTTKE NA NA

10A 2 46 INCH DIGITAL MENU SAMSUNG SMART TV OR EQUAL NA120 VOLT, 6 AMPS

10B 1 SMOOTHIE MENU ON THUMB DRIVE FRESHENS MATTINGLY NA NA

10C 1 COFFEE MENU ON THUMB DRIVE TBD BY SODEXO NA NA

11 1 COFFEE RINSE SINK ADVANCE TABCO DI-14-10

COLD WATER, HOT WATER, INDIRECT

WASTE TO FLOOR SINK WITH AIR GAP

NA

12 2 DIPPERWELL NEMCO

COLD WATER, INDIRECT WASTE TO

FLOOR SINK WITH AIR GAP,

NA

13 2 ICE CADDIE CAMBRO NA NA

14 1 FRAP BLENDER VITAMIX MODEL 36019 NA120 VOLT, 15 AMPS

15 1 TEA BREWER BNN TB3 FILTERED WATER120 VOLT, 14.4 AMPS

16 1 WATER FILTER FOR TEA BREWER TBD 1/2" COLD WATER NA

17 1 HAND SINK ADVANCE TABCO 7-PS-60COLD WATER, HOT WATER, WASTE, VENT

NA

18 1 REFRIGERATED COLD PAN

ATLAS WCMD-C-3FY (REPLACE

T-STATE WITH SWITCH)

DRAIN WITH VALVE FOR PERIODIC

CLEANING, PIPE TO FLOOR SINK

120 VOLT, 3.9 AMPS

19 2 WALL SHELVES ADVANCE TABCO WS-12-48 NA NA

20 2 BLENDERS HAMILTON BEACH MATTINGLY NA120 VOLT, 10 AMPS

21 1 SMOOTHIE RINSE SINK ADVANCE TABCO DI-1-10

COLD WATER, HOT WATER, INDIRECT

WASTE TO FLOOR SINK WITH AIR GAP

NA

22 1 BLENDER RINSER HAMILTON BEACH BCR-100 MATTINGLY

COLD WATER ON APPROVED BACK FLOW

PREVENTOR, DECK MOUNTED WASHING

MACHINE VALVE INCLUDED

NA

23 1 REACH IN FREEZER TRUE T-23F NA120 VOLT, 7.2 AMPS

24 1 ICE MAKER HOSHIZAKI KM650MAHCW, INDIRECT DRAIN TO FLOOR SINK 208 VOLT, 1 PH, 7.2 AMPS

25 1 ICE BIN HOSHIZAKI B-300 INDIRECT DRAIN TO FLOOR SINK NA

26 1 MOP SINK ADVANCE TABCO 9-OP-20COLD WATER, HOT WATER, WASTE, VENT

NA

27 1 THREE COMPARTMENT SINK ADVANCE TABCO FC-3-1620-18RL

COLD WATER, HOT WATER,ON APPROVED

GREASE INTERCEPTOR IF REQUIRED

NA

28 1 WALL SHELF ADVANCE TABCO WS-12-84 NA NA

29 1 WALL SHELF ADVANCE TABCO WS-15-84 NA NA

30 1 REACH IN REFRIGERATOR TRUE T-49 NA120 VOLT, 5.8 AMPS

31 1 ILLUMINATED SMOOTHIE SIGN

SOUTHEASTERN (INCLUDES INSTALL)

MATTINGLY NA120 VOLT, 6 AMPS

32 1 WPS STARBUCKS SIGN STARBUCKS NA NA

33 1 ELECTRIC TANKLESS WATER HEATER MINI120 VOLT, 21 AMPS, 2.4 KWCOLD WATER, HOT WATER,

KL

EQUIPMENT PLAN SCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

N

A L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

N

A L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 6: KEY PLAN - Daytona Beach

EM

EGRESS

DISTANCE 43'

EGRESS

DISTANCE 43'

FE

TO EXISTING BUILDING MAIN ENTRANCE

A

R

A

R

NEW 2' x 2' CEILING

TILE

9'-3" A.F.F.

EM

2'x2' RETURN AIR DIFFUSER

TYPE

2'x2' AIR SUPPLY DIFFUSER

A

R

EM

EXIT- EM

EMERGENCY & EXIT LIGHT COMBO

EMERGENCY LIGHT

EXIT LIGHT

SYMBOL

RECESSED LIGHT FIXTURE

PENDENT LIGHT

#9 WIRE

HANGERS AT

4'-0" O.C. DECK

ABOVE

STEEL FRAME ABOVE

2'x2' CEILING TILE

KL

LIFE SAFETY PLAN SCALE: 1/4"=1'-0"

REFLECTED CEILING PLAN SCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

N

A L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 7: KEY PLAN - Daytona Beach

CL

S - 3

S - 5

GFI

S - 7

S - 9

S - 11, 13

GFI

GFI

S - 15, 17

GFI

8'0" AFF.

S - 3

S - 4

S - 6

GFI

GFI

S - 2

GFI

8'0" AFF.

S - 8

S - 10

S - 12

GFI

GFI

GFI

S - 14

GFI

S - 16

GFI

S - 18

GFI

ELECT. PANEL - S

125 AMP, 3 PHASES

S - 19,21

NEW 2 TON A/C

MINI SPLIT SYSTEM

ON CEILING

S - 20,22

EM

S - 1

S - 1

EXIT

EXIT

EX

IT

CONNECT TO EXISTING

LOCAL LIGHTING CIRCUIT

CONNECT TO EXISTING

LOCAL LIGHTING CIRCUIT

1.) ASSURE ALL EXITING 120 VOLT BRANCH CIRCUIT FOR EMERGENCY WHITE

LIGHTING BATTERY PACK AND BACK UP OPERATED EXIT LIGHT. ALL

BATTERY OPERATED EXIT LIGHTS AND EMERGENCY WHITE LIGHTS SHALL

HAVE CAPACITY TO OPERATE FOR MINIMUM OF 90 MINUTES.

2.) ASSURE ALL EXISTING EMERGENCY AND EXIT LIGHTINGS TO CONNECT TO

LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHES.

SYMBOL LAMPSVOLTTYPE

EMERGENCY LIGHT - ELM2 N

EM

GENERAL NOTES:

120

EX120

1. EXIT SIGN-RED LETTERS, WHITE FINISH, BATT. PACK LIGHTOLIER #LLC2URW WITH EMER. FLOODS.

EMERGENCY LIGHTING - LIGHTOLIER #E5W (2-5.4w) TWIN LIGHT/BATTERY BACK-UP. WALL

MOUNTED, WHITE FINISH. MOUNT @ 108"AFF

DECORATIVE GLASS PENDANT

EXIT LIGHT LED INCLUDED

LED INCLUDED

RECESSED LED LIGHT FIXTURE

120

REMARK

120

EXIT- EM

EMERGENCY & EXIT LIGHT COMBO

AUTOMATIC WALL SWITCH WITH BUILT IN LIGHT LEVEL SENSOR

SIMILAR TO WATTSTOPPER WI-200 MODEL

9 WATT

EM

ALL ELECTRICAL DESIGN AND INSTALLATION

SHALL COMPLY WITH 2014 NEC

WALL SWITCH (1-WAY)

SINGLE OUTLET

S.P.S.T.

220 VOLTS

THERMOSTAT

WALL SWITCH (3-WAY)

TELEPHONE OUTLET PREWIRE

DATA OUTLET

QUAD OUTLET 120 VOLTS

ELECTRICAL LEGEND

DESCRIPTION

SYMBOL

REMARKS

TV CABLE

TV

DUPLEX OUTLET 120 VOLTS

LED RECESS LIGHT

EMERGENCY LIGHT

EXIT LIGHT

WALL SCONE LIGHT

EXIT- EM

EXIT & EMERGENCY LIGHT

COMBO

J - BOX

GENERAL NOTES:

= AUTOMATIC WALL SWITCH WITH BUILT IN LIGHT LEVEL

SENSOR SIMILAR TO WATTSTOPPER WI-200 MODEL

PENDANT LIGHT

DISCONNECT SWITCH

EXIT

KL

KL

ELECTRICAL POWER PLAN SCALE: 1/4"=1'-0"

LIGHTING PLAN SCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

N

A L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 8: KEY PLAN - Daytona Beach

LIBRARY MAIN

ENTRANCE

LIBRARY AREA

CIR

CU

LA

TIO

N D

ES

K

EXIST. STAIR CASE

EXIST.

EMERGENCY STAIR

CASE

MAIN

ENTRANCE

RECEPTION

ELECTRICAL

ROOM

NEW COFFEE

SHOP

NEW PATIO

BUILDING MAIN

BREAKER 'MBR'

R

U

N

1

.

5

"

C

O

N

D

U

I

T

A

B

O

V

E

C

E

I

L

I

N

G

PANEL 'S'

'MCB'

3PH,4W120/208V

BREAKER

EXISTING MAIN

TO XFMER

EXISTING

POWER RISER DIAGRAM

1200A

EXISTING WIREWAY

EXIST.

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

NEW MCBPANEL S - 125A

ELECTRICAL ROOM

EXIST. EXIST. EXIST.

APPROXIMATE 132 FT

FEEDER SIZES

(1) SET - (4) #2/0 Cu, (1) #2/0G. IN 1.5" CONDUIT

KL

KL

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 9: KEY PLAN - Daytona Beach

VENTILATION REQUIRED (CFM) CALCULATION

No OF PEOPLE = 12

TABLE 403.3 FMC-2010

PEOPLE OUTDOOR AIRFLOW RATE IN

BREATHING ZONE, Rp CFM/PERSON

7.5 CFM/ PERSON

VENTILATION AIR REQUIRED

Vz = RpxPz = 90 CFM

Pz = 12

TOTAL REQUIRED = 90 CFM

TOTAL PROVIDE = 100 CFM = OK ( PROVIDED BY EF-1 )

DINING & PREP AREA

REFERENCE NOTES

KEEP EXISTING AIR SUPPLY / RETURN GRILL

1

INSTALL 24" x 24" AIR BY PASS GRILL WITH 10"Ø FLEX DUCT

INSTALL NEW 2 TON A/C MINI SPLIT SYSTEM

2

3

HVAC LEGEND

EXISTING 2'x2' RETURN AIR DIFFUSER

EXISTING 2'x2' AIR SUPPLY DIFFUSER

A

R

BY PASS AIR RETURN FLEX DUCT

(SIZE IS SHOWN ON PLAN)

4INSTALL EXHAUST FAN EF-1 WITH CAPACITY OF 100 CFM FOR

VENTILATION

EXHAUST FAN FOR VENTILATION.

PROVIDE 100 CFM

NEW 2 TON A/C MINI SPLIT SYSTEM

MOUNT ON CEILING

5MOUNT NEW A/C CU ON THE EXTERIOR WALL

A

R

A

R

EXIST.

NEW NEW

12"Ø BY

PASS

HVAC NOTES:

THIS COFFEE SHOP IS LOCATED INSIDE LIBRARY.

THEN THEY ARE SHARING EXISTING HVAC SYSTEM.

EXIST.

EXIST.

150

CFM

150

CFM

100

CFM

NEW 2 TON A/C

MINI SPLIT SYSTEM

ON CEILING

1

1

1

A

R

2 2

3

4

5

SEAL PENETRATION

EXTERIOR WALL

SEALAND ALL AROUND

SHEET METAL BOX TO BE 1-1/2" MIN.

LARGER THAN SLEEVE

BACKDRAFT DAMPER FOR DRYER ONLY

CONTRACTOR TO PAINT W/

WEATHER RESISTANT PAINT

COLOR TO BE COORD. / ARCH/ OWNER

SEALANT ALL AROUND

EXTERIOR WALL PENETRATION DETAIL FORDRYER DUCT VENT

6" DIA. SHEET METAL

DUCT SLEEVE FOR

DRYER VENT

A/C HANGING

BRACKET (ADJUSTABLE)

W/ NUT AND WASHER AT

EACH END ( TOTAL OF 4 RODS )

3/8" ALL THREADED ROD

EXIST. 8" CMU BLOCK

MINI CU

2" x 2" STEELANGLE FRAMETOTAL OF 2

SCALE: N.T.S.THIS DESIGN FOR 160 MPH WIND LOAD

12" CONCRETE LUG BOLTS

KL

KL

FLOOR PLAN - HVACSCALE: 1/4"=1'-0"

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 10: KEY PLAN - Daytona Beach

3/4" C

3/4" C

CONNECT TO EXISTING

COLD WATER SUPPLY.

FIELD TO VERIFY

LOCATION

1/2" H & C

1/2" C

1/2" C

1/2" C

1/2" C

1/2" H & C

1/2" C

1/2" H & C

1/2" C

1/2" C

1/2" H & C

1/2" H & C

3/4" H

&

C

1/2" C

TANKLESS WATER

HEATER ON WALL

3/4" H & C

1/2" C

3/4" H

&

C

1. VERIFY ALL EXISTING CONDITIONS AND EXACT

LOCATIONS OF ALL EQUIPMENT TO BE PLUMBED PRIOR TO

THE COMMENCEMENT OF WORK. COORDINATE ALL

WORK WITH ALL TRADES.

2. COMPLETE AND WORKING PLUMBING SYSTEMS SHALL BE

IN ACCORDANCE WITH THE 2017 FLORIDA PLUMBING

CODE AND LOCAL AUTHORITY HAVING JURISDICTION (AHJ).

3. PRESSURE AND HYDROSTATICALLY TEST THE PIPING, AS

APPLICABLE, TO INSURE THE ABSENCE OF LEAKS IN

ACCORDANCE WITH THE 2017 FPC

BUILDING/PLUMBING CODE. DISINFECT ALL DOMESTIC

WATER PIPING IN ACCORDANCE WITH THE 2017 FLORIDA

BUILDING/PLUMBING CODE.

4. NEW WASTE DRAIN AND VENT PIPING SHALL BE PVC DWV

TRENCHES SHALL BE BACKFILLED AND COMPACTED.

NEW CW AND HW PIPING SHALL BE CPVC PIPING EQUAL

TO FLO GUARD GOLD. WRAP NEW HOT WATER PIPING WITH

1" R-4 PER INCH (PER THE 2017 FLORIDA MODEL ENERGY

CODE) CELLULAR RUBBER INSULATION EQUAL TO

ARMSTRONG ARMAFLEX. NOTE: BRANCH PIPING LESS

THAN 12' MAY BE INSULATED WITH 1/2" INSULATION PER

SAME CODE.

5. SECURE ALL REQUIRED PERMITS AND PAY ALL

ASSOCIATED FEES.

3 - COMPARTMENT SINK (18"L x18"W x12"D)

CUBIC CONTENT = 3 x (18" x 18" x 12") = 11,664 IN³

MOP SINK (18"L x 24"W x 12"D)

CUBIC CONTENT = ( 18" x 24" x 12" ) = 5,184 IN³

HAND SINK (12"L x 12"W x 8"D)

CUBIC CONTENT = 1 X (12" x 12" x 8") = 1,152 IN ³

RINSE SINK (12"L x 12"W x 8"D)

CUBIC CONTENT = 2 X (12" x 12" x 8") = 2 x 1,152 = 2,304 IN ³

TOTAL CUBIC CONTENT = 11,664 + 5,184 + 1,152 + 2,304 = 20,304 IN ³

20,304 IN³ / (231 IN³/GAL) = 87.89 GAL.

FLOW FACTOR = 1

ACTUAL DRAINAGE LOAD = 1 x 87.89 = 87.89 GMP FLOW RATE

REQUIRED GREASE TRAP CAPACITY 87.89 GMP

PROVIDE GREASE TRAP CAPACITY OF 100 GMP = OK

1.5" V

FS-1

2"

FS-1

2"

FS-1

2"

2"

H.S

FS-1

3"

M.S

2"

3"

FS-1

2"

FD-1

FS-1

2"

FS-1

2"

3"

3"

3"

2"

3"

CONNECT TO EXISTING

SANITARY LINE.

FIELD TO VERIFY LOCATION

1.5" V

1.5" V

1.5" V

1.5" V

1.5" V

1.5" V

1.5" V

2" STUDOR

VENT TO OUTSIDE WALL

3

"

V

.

2

"

V

.

2

"

V

.

100 GAL

GREASE TRAP

BELOW SLAB

N

E

W

3

"

Ø

S

A

N

I

T

A

R

Y

L

I

N

E

N

E

W

3

"

Ø

G

R

E

A

S

E

L

I

N

E

3"

NEW 4" THICK. CONC. SLAB MIN. 3000 PSI

COMPRESSIVE STRENGTH AFTER 28 DAYS W/

6x6xW1.4xW1.4 WELDED WIRE MESH PLACED AT MID

DEPTH ON 6 MIL. VAPOR BARRIER ON 4" MIN. TERMITE

TREATED COMPACTED FILL

EXISTING CONC. SLAB

TYPICAL CONCRETE SLAB REPAIR

#4 DOWEL 4" EMBED TO EXISTING

CONC. SLAB & 10" LAP TO NEW CONCRETE

SLAB AT SPACING OF 48" O.C.

WITH SIMPSON EPOXY ET

NOTE: IF THE WIDTH OF TRENCH IS LESS THAN

16", DOWEL SHALL NOT BE REQUIRED

3

/

4

"

H

&

C

3

/

4

"

C

CONNECT TO EXISTING

COLD WATER SUPPLY.

FIELD TO VERIFY LOCATION

3

/

4

"

H

&

C

MS

1/2

" H

&

C

3-COMP

1/2

" H

&

C

ICE M.

1

/

2

"

C

BL.R.

SM.R.SINK

1

/

2

"

H

&

C

PROVIDE BACK FLOW PREVENTOR,

DECK MOUNTED WASHING MACHINE

VALVE INCLUDED

HS

1

/

2

"

H

&

C

1

/

2

"

H

&

C

1

/

2

"

C

1

/

2

"

C

1

/

2

"

C

3

/

4

"

C

1/2

" C

1/2

" C

W.F.

DIP.&FAUCET

3

/

4

"

C

SHUT OFF VALE

1

/

2

"

C

1

/

2

"

C

DIP.

W.F.

DIP.

COF.R.SINK

W.F.

3

/

4

"

C

TANKLESS

WH.

3

/

4

"

H

&

C

2"

2"

3" FD-1

2"

2"

2"

2"

3"

3"

2"

2"

3"

CUT 12" W. CONCRETE TRENCH FOR

SANITARY PLUMBING PIPE.

AFTER PLUMBING WORK DONE, POUR 4"

THICK. CONC. SLAB WITH 3000 PSI

CONCRETE WITH WIRE MESH. PROVIDE

THERMAL TREATED FOR SOIL AND

VAPOR BARRIER PRIOR TO POUR NEW

CONC. SLAB

3"

NEW 3"Ø SANITARY LINE

NEW 3"Ø GREASE LINE

100 GAL

GREASE TRAP

BELOW GROUND

CONNECT TO EXISTING

SANITARY LINE.

FIELD TO VERIFY LOCATION

COLD WATER ( C-PVC SIZE SHOWN ON PLAN )

HOT WATER ( C-PVC SIZE SHOWN ON PLAN )

C

H

SAN

SANITARY LINE ( C-PVC SIZE SHONW ON PLAN )

GREASE

GREASE LINE ( C-PVC SIZE SHONW ON PLAN )

FLOOR SANITARY PLANSCALE: 1/4"=1'-0"

KL

FRESH WATER PIPING PLANSCALE: 1/4"=1'-0"

WATER DIAGRAMDRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ

Page 11: KEY PLAN - Daytona Beach

GROUT AROUND

RAISED DRAIN NECK

KL

DRAWING NUMBER

DATE

PROJECT

CAD FILE

CHECKED

DRAWN

BY

5-02-18

DA

TER

EV 1 2

PROFESSIONAL SEAL

427

Palm

Cre

st L

ane

Lake

Mar

y, F

l 327

46Ph

one

(407

) 361

-801

7, e

mai

l: kl

engi

neer

ing1

1@gm

ail.c

om

FLO

RID

A C

.A #

3161

9

Date: 5-02-2018

KL

ENG

INEE

RIN

G

3 4

DES

CR

IPTI

ON

BET

HU

NE

CO

OK

MA

N U

NIV

ERSI

TYLI

BR

AR

YD

ayto

na B

each

, FL

P

R

O

F

E

S

S

I

O

NA L

E

N

G

I

N

E

E

R

K

H

A

N

H

L

E

No. 70935

STATE OF

L

I

C

EN

S

E

F

L

O

R I

D

A

C

O

UQ