Top Banner
Keller America Inc User’s Guide Rev. 07/20
27

Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Jul 14, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Page 2: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure
Page 3: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20 Table of ContentsI. CompanyInformation..................................................................................2II. ContactInformation……......……………………………………………………………………..2III. ProductApplicability.………....………………………………………………………………….2IV. ProductOverview…………………………………………………………………………………….3V. Lightning/SurgeProtection.………………………………………………………………………4VI. Options/Accessories.………………………………………………………………………………5VII. Installation……....………………………………………………………………………………………6VIII. Useandcare...…………….…………………………………………………………………………..8IX. TermsandConditions…....…………………………………………………………………………9X. Appendix A. Generic2-wireCurrentLoopConfiguration………………………………A-1 B. Generic3-wireVoltageOutputConfiguration…………………………..A-1 i. Econoline 1. 4-20mA,Cable..................………………………………….......A-2 2. 4-20mA,mPmConnector..................………………………A-2 3. 4-20mA,M12Connector...................………………………A-2 4. 0.5-4.5VDC,Cable................…………………………………..A-3 5. 0.5-4.5VDC,mPmConnector................……………………A-3 6. 0.5-4.5VDC,M12Connector................……………………A-3 ii. Valueline 1. 4-20mA,Cable................…………………………………………A-4 2. 4-20mA,DIN43650Connector................…………………A-4 3. 4-20mA,MIL-C-26482Connector.................……………A-5 4. 0-5/10VDC,Cable.................……………………………………A-4 5. 0-5/10VDC,DIN43650Connector..................……………A-4 6. 0-5/10VDC,MIL-C-26482Connector.................………..A-5 iii. Preciseline 1. 4-20mA+RS485,Cable................…………………………….A-6 2. 0-5/10VDC+RS485,Cable.................………………………..A-63.SDI-12+RS485,Cable.........................................…………A-6 4. 4-20mA+RS485,MIL-C-26482Connector...................A-7 5. 0-5/10VDC+RS485,MIL-C-26482Connector.....………..A-7 6. SDI-12+RS485,DIN43650Connector........................…A-6 C. SubmersibleLevelTransmitters iv. Levelgage 1. 4-20mA,Cable................…………………………………………A-8 2. 0-5/10VDC,Cable.................………………………………….…A-8 v. LevelRat 1. 4-20mA+RS485,Cable..............………………………………A-8 2. 0-5/10VDC+RS485,Cable..............…………………………A-8 vi. Acculevel 1. 4-20mA+RS485,Cable.………………..............………………A-8 2. 0-5/10VDC+RS485,Cable..............…………………………A-8 3. SDI-12+RS485,Cable..................................................A-9 vii. Microlevel/Nanolevel 1. 4-20mA+RS485,Cable...………………………………...........A-9 D. InstallationTips.………………………………………..…………..............…A9-11

Page 4: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

I. Company Information

KellerAmericaIncistheNorthAmericansubsidiaryofKellerAGfürDruckmesstechnik,whichcontinuesastheleaderinlevelandpressuresensing.Fromhumblebeginnings,Kellernowprovidesitsproductsandexpertisethroughaworldwidenetworkoffacto-ry-trainedprofessionals.

Withtheadventofinexpensive,miniaturizedmicroprocessors,Kellercontinuestoad-vancethestate-of-the-artinfullypackagedpressuretransmitters,withTotalErrorBandperformancenotpossiblejustafewshortyearsago.Annualsensorproductionnowexceeds1millionpieces.

DoingbusinesswithKelleriseasyandmostinquiriesareansweredwithin24hours.StandarddeliveryonU.S.-assembledproductsis3daysARO.Weofferconvenienttermswithapprovedcreditandacceptmostmajorcreditcards.

AtKeller,providingcustomerswithsuperiorvalueisawayoflife.

II. Contact Information

KellerAmerica,Inc.351BellKingRdNewportNews,Virginia,23606P:877-253-5537F:757-596-6659Web: www.kelleramerica.comEmail: [email protected]

III. Product Applicability:Unlessotherwisenoted,thismanualcontainsuserinformationforthefollowinglevelandpressureinstrumentationprovidedbyKellerAmerica:Acculevel™,Levelgage™,LevelRat™,Microlevel™,Econolevel™,andNanolevel™submersibleleveltransmitters;Econoline™,Valueline™,andPreciseline™abovegroundpressuretransmitters.

Electronic copies of this user’s guide can be found at kelleramerica.com.

Page2

Page 5: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

IV. Product Overview - Level Transmitters

Levelgage-TheKellerLevelgageisageneralpurposesubmersibleleveltransmitteravailablein1%and0.5%BRTEBaccuracy.Constructedfrom316Lstainlesssteel,itisideallysuitedformostfreshwatermonitoringapplications.Withstandardconstruction(i.e.EPDMandXLPE)materials,theLevelgagehasbeencertifiedtoNSF61andNSF372standardsforuseindrinkingwater.Itisavailableincustomrangesfrom0…3ftWCto0…900ftWC.Cablelengthsarecuttouserspecifications.TheLevelgageisalsoavailableinvariousoutputconfigurations,including4…20mA,0…5VDC,and0…10VDC.

Acculevel-TheAcculevelfromKellerisahighaccuracysubmersibleleveltransmitter.IncorporatingallofthefeaturesoftheLevelgageincludingtheNSF61andNSF372certifications,theAcculevelhasadditionalfeaturesthatprovideenhancedfunctionality,includingdualoutputs;i.e.,oneanalog(4…20mA,0…5VDC,0…10VDC)andonedigital(RS485).TheRS485interfaceprovideslevelandtemperatureinformationandallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.Additionally,theAcculeveliscapableofgreateraccuracythantheLevelgage,withastandardaccuracyof0.25%BRTEBandanoptional0.1%BRTEB.TheAcculevelcanbemanufacturedin316Lstainlesssteelortitaniumforincreasedresistancetocorrosion,notablyfromseawater.

Acculevel SDI -TheAcculevelSDIisaversionoftheAcculevelhighaccuracysubmersibleleveltransmitterthatisavailablewithSDI-12orRS485digitalcommunicationprotocols.Itisavailablewithstandardaccuracyof±0.1%FSTEBinrangesupto900ftWCandoptionalUSGSOSWaccuracyforrangesupto70ftWC.TheAcculevelSDIcanbemanu-facturedinstandard316Lstainlesssteeloroptionaltitaniumforincreasedresistancetocorrosion,notablyfromseawater,carriestheNSF61andNSF372approvals.

LevelRat -TheKellerLevelRatisspecificallydesignedtoprovide0.5%BRTEBaccuracyforlevelindicationingrease-ladenenvironmentscommonlyfoundinliftstationsservingcommercialconcerns.TheLevelRatdesigntakesastepawayfromthelargeandbulkyprotectioncagedesignsbyutilizingauniquediaphragmmaterialthatoffersthenon-stickpropertiesofTeflonandprovidesaddedresistancetodamagefromdebris.TheLevelRatprovidesdualoutputs;yourchoiceofanalogoutputs(4…20mA,0…5VDC,or0…10VDC)plusonedigital(RS485)forlevelrangesfrom0…5ftWCto0…100ftWC.

Microlevel-TheMicrolevelcombinesthecapabilityoftheAcculevelwithaclassleading0.63”(16mm)outsidediameter.TheMicrolevelisavailableinfullscalerangesfrom0…3ftWCthrough0…900ftWCandprovides0.25%BRTEBaccuracy.LiketheAcculevel,italsoprovidesboth4…20mAanalogandRS485Digitaloutput.TheRS485interfaceprovideslevelandtemperatureinformation.Italsoallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.

Nanolevel-TheNanolevelisuniquelydesignedforhighaccuracymeasurementofverylowpressureranges.TheNanolevelisavailableinfullscalerangesfrom0…4inWCthrough0…10ftWCandisavailablewithstandardaccuracy0.25%BRTEBand0.1%BRTEBoptional.LiketheAcculevel,italsoprovidesboth4…20mAanalogandRS485Digitaloutput.TheRS485interfaceprovideslevelandtemperatureinformation.Italsoallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.

Page3

Page 6: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Econolevel-TheEconolevelbyKellerisalowcostgeneralpurposesubmersibleleveltransmitterdesignedforhighvolumeapplications.Itisavailableinnominalpressurerangesfortankandwelllevelmonitoringapplications.TheEconolevelprovidesa4…20mAanalogoutputthatiscompatiblewithmostSCADAsystemsandPLCs.Mini-mumorderquantitiesapply.

IV. Product Overview cont’d - Pressure Transmitters

Econoline-TheEconolinebyKellerisalowcostgeneralpurposepressuretransmitter.Itisavailableinnominalpressurerangesbetween30psiand10,000psiandwithathread-ed¼”NPTpressureconnection.Idealfortank,pump,andpipepressuremonitoringapplication,itprovidesastandard4…20mAanalogoutputcompatiblewithmostSCADAsystemsandPLCs.Anoptional0.5…4.5VDC(ratiometricornon-ratiometric)analogout-putisalsoavailableonrequest.

Valueline-TheValuelinebyKellerisahighlyversatileandaccuratepressuretransmitter.Itisavailableincustompressurerangesfrom0…2through0…15,000PSIandyourchoiceofelectricalconnectionsincludingattachedcable,DIN43650,andMIL-C-26482connec-tors.Theattachedcableversionisfullysubmersible,makingittheidealchoicewheninstalledinavalvepitorotherenvironmentpronetoperiodicflooding.TheValuelinealsocarriestheNSF61andNSF372approvalsfordrinkingwaterapplications.

Preciseline -ThePreciselineisourmostaccurateabove-groundpressuretransmitter.Withstandardaccuracyof0.25%BRTEBandoptional0.1%BRTEB,a¼”NPTpressureconnection,anddualoutputs(analoganddigital)thePreciselineoffersversatilityindesignandapplication.LiketheAcculevel,theanalogoutputcanberescaledviatheRS485interface.TheRS485interfacealsoallowstemperaturedatatoberetrievediftheapplicationdemands.LiketheValueline,thePreciselineisincludedintheNSF61and372approvals.

Preciseline SDI-ThePreciselineSDIishighlyprecisepressuretransmitterthatisavail-ablewithSDI-12orRS485digitalcommunicationprotocols.Itisavailablewithstandardaccuracyof±0.1%FSTEBinrangesupto900ftWCandoptionalUSGSOSWaccuracyforrangesupto70ftWC.ItcomeswithyourchoiceofattachedcableorMIL-C-26482connectorelectricalconnections.Thecableversionisfullysubmersible,makingittheidealchoiceinenvironmentspronetoperiodicflooding,whiletheNSF61andNSF372approvalsmakethePreciselineSDIsuitableforuseindrinkingwaterapplications.

V. Lightning / Surge Protection:

Asofthiswriting,Kelleristheonlypressure/leveltransmittermanufacturerintheworldtoprovide,atnoadditionalcharge,alifetimewarrantyagainstdamagecausedbylight-ningand/orelectricalsurge.Thisguaranteeappliestothe4…20mAoutputversionofthefollowingproducts:Levelgage,Acculevel,LevelRat,Microlevel,Valueline,andPreciseline.Thiswarrantyapplieseveninthecaseofadirectlightningstrike.Theuser’sliabilityislimitedtoshippingcoststoKellerAmerica.

Page4

Page 7: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

VI. Options /Accessories:

Titanium Construction -OptionalfortheAcculevelandPreciseline.Highlyrecommend-edforbrackishandseawaterapplications.

External Surge Protector-Recommendedforlightning/surgeprotectionofuser’spowersupply/readout/PLC,etc.TobeusedinconjunctionwithLevelgage,Acculevel,LevelRat,Econolevel,Microlevel,Nanolevel,Valueline,orPreciselinetransmitters.

½” NPT Pipe conduit fitting -½”NPTmalefitting,allowsrigidmountingto½”conduitforLevelgage,Acculevel,orLevelRatsubmersibletransmitters.ItcanalsobeaddedtoourPreciselineandValuelinepressuretransmitters.

Drying Tube Assembly-Cleartubefilledwithindicatingdesiccant,attachesdirectlytocableventtube,interceptswatervapor.Highlyrecommendedwhenoperatingisinhighhumidityconditions.Mustbeperiodicallyrenewedasdesiccantbecomessaturated,turningcolorfromblue(dry)topink(saturated).

Bellows Assembly-Alternativetothedryingtube,thisaneroidbellowsattachestocableventtubeandrequiresnoperiodicmaintenance.Notethattheuseofthebellowsresultsinaclosedreferencepressuresystemsubjecttozeroshifterrorsinducedbychangingtemperaturesofupto0.0004psi/ºC.Notrecommendedforusewithaccuracyrequirementsof±0.25%FSorbetter,orranges<2psi.

Electrical Connectors -mPm393isoptionalfortheEconoline,DIN43650andMIL-C26482areoptionalforValuelineandPreciseline.ThemPm393andMIL-C26482matingconnectorsfeaturesoldercupswhiletheDIN43650incorporatesscrewterminals.

RS485 Converter/Cable -FortheuserwhowishestocommunicatewiththeirAcculevel,LevelRat,Nanolevel,Microlevel,orPreciselinetransmitterviatheRS485digitalinterface.AvailableinRS232andUSBversions,alongwithcableadapters,asneeded,andCCS30Software(alsoavailablefordownload,freeofchargefromwww.kelleramerica.com).Consultfactoryfordetails.

Termination Enclosure-Convenientoptioncomplementinggauge-typepressure/leveltransmitters,whereitisdesiredtoterminatethetransmittercableclosetothemea-surementpoint.ItincludesaNEMA4Xclearfrontenclosure(7.9X4.7X3.5inches)withtwo,liquid-tightcablefittings(onein,oneout),aterminalstrip,andampleroomformountingadryingtubeorbellowsassembly.

Stabilizing Weight-ZincpropshaftanodeadaptedtofitØ21mmO.D.ofLevelgage,Acculevel,andLevelRatsubmersibleleveltransmitters.Aidsincorrosionresistanceaswellashelpsensurethatthecableremainstautinturbulentconditions.

Cable Hanger-Singleeyefor0.230”diametercable.Designedtogripthecablejacketandprovideasuspensionpointforinstallationofcabledtransmitters.

Pressure Test Adapters -Designedtofacilitatecalibrationandmaintenancetesting,thesespecialtyadaptersallowforconnectionofthevariousKellerleveltransmitterstoapressurecalibrator.

Page5

Page 8: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Digital Display / Meter -TheTRIDENTdisplaybyPrecisionDigitalisaversatileandcosteffectiveprocessmeterprovidinganeasytouseandreaddisplay/controllerforyourlevelandpressuremeasurementapplication.Formoreinformationandtechnicalsup-port,pleasecontactPrecisionDigitalat(800)343-1001oronlineatwww.predig.com.

VII. Installation:

Thefollowingisimportantinstallationandgeneralmaintenanceinformationforsub-mersibletransmitters.PleasecontactKellerAmericaforadditionalinstruction.

Supply Voltage-Adequatesupplyvoltageiscriticaltoensureproperoperationof4-20mApressureandleveltransmitters.Withouttheminimumrequiredvoltageavailableatthetransmitter,thetransmitterwillnotoutputthecorrectanalogvalue.

Manyanalogtransmitterswillappeartooperateproperlyevenwhenthesupplyvoltageisnotadequatetopowertheloopwhenthetransmittershouldbeoutputting20mA.Forexample,a10voltsupplymayappeartobeenoughtopowerananalogtransmitterwhenitisoutputting4mAwithzeropressureapplied,butasthetransmitter’soutputincreaseswithincreasingpressure,voltagedropsacrossotherdevicesintheloop(ana-loginputdevices,cableand/orexternalbarrierdevices)mayreducethesupplyvoltagetothetransmitterandpreventitfromprovidingthecorrectoutputaboveacertaininputpressure/levelthreshold.

KellerAmerica’s4-20mApressureandleveltransmittersfeaturemicroprocessorbasedsignalconditioning.Duringpowerup,thecircuitperformsachecksequencewhichde-termineswhetherthereissufficientsupplyvoltagetopoweralldevicesontheloop,bysettingtheoutputto~110%ofthemaximumvalue,i.e.,~22.5mA.Ifthesupplyvoltageisnotsufficienttosupply22.5mAtothecircuit,thenthemaximumpossiblecurrentwillbeseenontheanalogoutput,e.g.,17mA,andthetransmitterwillnotinitiatenormaloperation.

Thebenefitofthistechnologyisthattotalloopimpedanceisaccountedforpriortoplacingtheequipmentintoservice,preventingfalseindicationswhenthevoltagesupplyisinsufficienttosupporttheloopwithmaximumpressureapplied.

Mostcurrentloopscontainanaloginputdevices,indicatorsorothercomponentshavinginputimpedanceswhichmustbeconsideredwhencalculatingthesupplyvoltagesneed-ed.Forexampleananaloginputdevicewitha250OhmInputImpedancewillrequireanadditionalvoltageof5.5VDC(250x0.022=5.5)inadditiontotheminimumsupplyvoltagenecessaryforthetransmittertooperateproperlyovertheentirerange.

Page6

Total LoopImpedance

IndicatorAnalog Input

Device

Cable

ResistanceIS Barrier

4 - 20mA outputLevel / Pressure

Transmitter

Page 9: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Thecalculationsbelowareusefulinidentifyingtheminimumsupplyvoltageneededforacurrentloopwithadditionallineimpedancesorconversely,themaximumcurrentloopimpedanceallowedforagivensupplyvoltage.

Minimumsupplyvoltagewithlightningprotectionoptioninstalled: 11VDC+(Totalloopimpedancex0.022)

Minimumsupplyvoltagewithoutlightningprotectionoptioninstalled: 8VDC+(TotalloopImpedancex0.022)

Maximumallowableloopimpedancewithlightningprotectionoption installed: (SupplyVDC–11VDC)/0.022

Maximumallowableloopimpedancewithoutlightningprotectionoption installed: (SupplyVDC–8VDC)/0.022

Transmitter Anchoring-ItisrecommendedthatKellersubmersibletransmittersbeinstalledinastillingwellorattachedtorigidconduitviaaconduitfittingintegraltothetransmitter,inordertopreventdamagetothetransmitterfromimpactwithimmovableobjects.Itisnotadvisabletotiethetransmittertoapumportopiping,asanyproblemwiththetransmittercouldrequirethatthepumpbepulledfromtheinstallation.

Someapplicationsrequirethetransmittertobesuspendedwithoutaprotectivestillingwellorconduitattachment.Inallinstallations,careshouldbetakentopreventdamagetothesubmersiblecable.

Transmitter Submersion -Damagetosubmersiblecablecanleadtofailureofthetrans-mitter.Kelleremploysaruggedcablejacketmaterialstominimizetheriskofcutsandabrasion.Still,takecarewhenloweringyourtransmitterintothewell,makingsurethecabledoesnotdragoversharpedges.Avoiddroppingthetransmitterfromthesurface.Donotsubmergeelectricalconnectionendofcable.

Condensation protection -Kellerhasoptimizedthesizeofthecableventtominimizetheoccurrenceofwatervaporincursion.Inareasofhighhumidity,itmaybedesirabletouseaDryingTubeAssembly(desiccant)orBellowsAssemblytopreventwatervaporfromenteringtheventtube.ContactKellerAmericafororderinginformation.

Bending of Cable-Ourjacketedcableisquiteflexible.However,caremustbetakentoensuretheventtubeintegraltothecableisnotcrimpedwhenbendingthecabletosuityourinstallation.Itisrecommendedthatthecablenotbebenttoaradiussmallerthan1inch.

Cable Compression -Manyusersemployacompressionfittingtosecureourcableasitentersajunctionbox.Caremustbetakenthatthefittingisnotovertightened,causingdamage to the cable and/or crimping the vent tube.

Page7

Page 10: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Position Sensitivity-Thetransmittershouldbeinstalledinaverticalposition,other-wiseitmayexhibitanoffset.Ifthetransmittermustbeinstalledinanypositionotherthanvertical,measuretheoutputwithnopressureappliedpriortoconnectiontoyourdisplay,PLC,orcontroller.Usethemeasuredvalueforyourzeropoint.

VIII. Use and Care:

Safe Handling-SafehandlingofKELLERpressuremeasurementdevicesisaccomplishedifanominalamountofcareistaken.Thingstoavoidare:•Sharpimpactagainsthardsurfaces•Contactwithchemicalsknowntobecorrosivetothematerialsofconstruction•ProbingofpressuresensingmembranewithANYTHING

Limits of Pressure -KELLERpressuresensors,transducersandtransmittersaredesignedtowithstandacertainamountofoverpressurewithoutdamageorcalibrationshift.Itcanrangefrom15Xforthelowerpressurerangesto1.1Xforthehighestranges.Thisvalueisdifferentforeachproductandisreferredtointheproductliteratureas“Overpressure”.Itistheuser’sresponsibilitytoensurethattheproperKELLERproductischo-senfortheparticularpressureconditionsexpected.

Environmental conditions-EachKELLERproductisdesignedtobecompatiblewithaparticularenvironment.Itistheuser’sresponsibilitytoensurethattheKELLERproductisnotexposedtoanenvironmentalconditionforwhichitisnotdesigned.Thesecondi-tionscanincludeoperatingtemperaturerangeandexposuretohigh-pressurewaterjets,medianotcompatiblewiththematerialsofconstruction,submergenceoftransmittersnotdesignedforthatpurpose,orpotentiallyexplosiveatmospheres.AKELLERengi-neercanhelptheuserdeterminethecorrectchoiceofenclosuretosuittheparticularapplication.

Electrical conditions -EachKELLERproductisdesignedtooperateproperlywithinaspecificrangeofelectricalconditions.Thespecificproductlabeldefinestherating(s),ifany,thatappliestotheproducttowhichitisaffixed.Alltransmittersaredesignedtowithstandreversepolarityaswellasovervoltagetoacertainextent.Itistheuser’sresponsibilitytoensurethatallelectricalconnectionsaremadetotheKELLERproductsinaccordancewithKELLERrecommendationsaswellaslocalelectricalcode.Wirecolorsorconnectorpin-outsareeitherprintedonthelabelaffixedtotheproductorprovidedseparately.

Cleaning-WARNING!Undernocircumstancesshouldthemembrane,pressureinputport,ornosecaptotheKELLERdevicebeprobedwithanyobject.Damagetothesens-ingmembraneispermanentand,inmostcases,requiresrepairorreplacement.

Regardingmedia-isolatedproducts,shouldthepressureinputornosecaptothesensor,transducer,ortransmitterbecomefouled,itmaybecleanedinthefollowingmanner:

Thedeviceshouldbeslowlyloweredmembrane-endintoasolutionofwarm,soapywater.Careshouldbetakennottosubmergetheentiredevice,unlessitisspecificallydesignedforcontinuoussubmergence.Agitateinthesolutionfor20-30secondsoruntil

Page8

Page 11: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

theinput/nosecaptothedeviceisclear.Finishbystirringinfreshwater.Wipedrywithasoftragortowel.

Asoapscumandhard-waterstainremovermayalsobeused,ifnecessary,butonlyaftercompatibilitywithanyo-ringsealsintheKELLERproductisdetermined.Followthesolventmanufacturer’srecommendationsforsafehandling.

IX. Terms and Conditions:

Offers -Unlessotherwiseindicated,quotedpricesarevalidfor60daysfromthedateofthequotationandapplytoproductsthatarescheduledforshipmentwithintwelvemonthsfromthedateoftheBuyer’spurchaseoratKellerAmerica,Inc.shippingcapabil-itiesatthetimetheorderisentered,whicheverislater.

Acceptance of order-Anypurchaseordertobeacceptedhastorefertoaquotation,whetherdeliveredbysurfacemail,e-mailorfacsimile.Alloralordersmustbeconfirmedinwriting.Byreferringtothisquotation,BuyeracceptsandadoptstheGeneralTermsandConditionsofSale(“TermsandConditions“)totheexclusionofanyadditionalordifferenttermsappearinginBuyer’spurchaseorderandwaivesanyrightBuyermayhavetoenforceanysuchadditionalordifferentterms.OurConfirmationofOrderorInvoicevalidatesorders.Ordersforcustom-configuredproductsarebuilttoyourspecifi-cationandthereforemaynotbecanceledoncetheorderhasbeenconfirmed.

Date of shipment-TheestimatedshippingcapabilitystatedonthequotationisgivensolelyfortheBuyer’sinformationanddoesnotconstituteacommitmenttodeliverproductsinaccordanceherewith.Buyermayrequestaspecificshippingdateorshippingschedule.KellerAmerica,Inc.willscheduleshipmentsbaseduponBuyer’srequestandKellerAmerica,Inc.’sshippingcapabilitiesatthetimeBuyer’spurchaseorderispro-cessed,atwhichtimeKellerAmerica,Inc.willissuetoBuyeraformalAcknowledgmentofOrderthatwillindicatetheestimatedshippingdate(s).Aftertheshipmentshavebeenscheduled,BuyermaynotcancelorpostponeascheduledshipmentunlessBuyersub-mitsitsrequestinwritingandKellerAmerica,Inc.consentsbyissuinganewacknowl-edgment.

Anyrequesttocancelortorescheduletheshipmentthatisreceivedlessthan21daysfromthedatescheduledfortheshipmentoftheproductscoveredbytherequestmayberejectedasuntimely,ormaybeaccepteduponpaymentofthecancellationchargeof20%orareschedulingchargeof10%ofthesalespriceshownonthisquotationatKellerAmerica,Inc.’soption.KellerAmerica,Inc.willuseitsbesteffortstoshiponorevenbe-foretheestimatedshippingdatesindicated,butwillnotbeliableforanydelayorfailuretodeliver.KellerAmerica,Inc.shallnotbeliableforanyspecial,incidentalorconsequen-tialdamagesresultingfordeliverydelaysorinabilitytodeliver. AllgoodsormaterialssuppliedbyKellerAmerica,Inc.remainitspropertyuntiltotalpay-mentisreceived.AllsuchgoodsandmaterialsareatthesoleriskoftheBuyerandintheeventofbeingdamaged,destroyedorlostafterdelivery.KellerAmerica,Inc.isentitledtoreceivethetotalpaymentofthosegoods.

Page9

Page 12: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Price -Unlessotherwisespecifiedinthequotation,ourpricesareinUSdollars(USD).Theyareexclusiveoffreightcostsandofallstateandlocalsales,use,excise,privilegeandsimilartaxes.SuchtaxesimposedonKellerAmerica,Inc.orwhichKellerAmerica,Inc.hasadutytocollectinconnectionwiththesaleordeliveryoftheproductsde-scribedonthequotationshallbepaidbyBuyerandwillappearasseparateitemsontheinvoice.

Shipment / freight -DeliveriesareF.O.B.NewportNews,VA.TitleandriskoflossshallpasstoBuyerupontenderoftheproductsbyKellerAmerica,Inc.toacommoncarrier.InabsenceofspecificwritteninstructionfromBuyer,KellerAmerica,Inc.willselectthecommoncarrier,butKellerAmerica,Inc.shallnottherebyincuranyliabilityinconnec-tionwithshipment.Buyershallberesponsibleforanyfreightcharge.Declaredvalueforeachshipmentwillbeamaximumof$100regardlessoftheactualvalueofthegoods,notwithstandingwritteninstructionsfromtheBuyerspecifyingahigherdeclaredvalue.Iftheproductsareshippedfreightprepaid,BuyershallpayKellerAmerica,Inc.theap-propriatefreightcharges,whichwillbeshownasseparateitemsontheinvoice.

Payment -TermsareindicatedonourConfirmationofOrderandonourInvoices.KellerAmerica,Inc.willsubmitaninvoicetoBuyerforeachshipmentatthetimeofshipment.Exceptasotherwiseprovidedonthequotation,BuyershallpaytheamountinvoicedbyKellerAmerica,Inc.within30daysfromthedateoftheinvoice.IfinthejudgmentofKellerAmerica,Inc.thefinancialconditionorpaymentrecordofBuyeratanytimedoesnotjustifyshipmentunderthepaymenttermsspecifiedabove,KellerAmerica,Inc.mayrefusetoshipunlessitreceivespaymentinadvance,oratitsoption,paymentupondelivery.2%interestpermonthischargedonoverdueaccounts.

Documentation -Theinformationgiveninourdocumentation,printedmatter,datasheetsandpricelistsiswithoutcommitment.Thisinformationspecifiestheproductbutisnowarranty,unlessagreedinwriting.

Warranties -KellerAmerica,Inc.warrantsthattheproductsthatitsellsaredeliveredfreefromdefectsinmaterialandworkmanship.KellerAmerica,Inc.’sliabilityunderthiswarrantyislimitedtoreplacingorrepairingorissuingacreditnote,atitsoption,foranyproductwhichisreturnedtothefactory,transportationchargesprepaid,andwhichisdeterminedbyKellerAmerica,Inc.tobedefective.Thiswarrantydoesnotapplytobatteriesandaccumulatorsandtoanyproductwhichhasbeensubjectedtoordam-agedduetomisuse,misapplication,negligenceoraccident,orwhichhasbeenrepairedoralteredwithoutexpresspriorandwrittenconsentfromKellerAmerica,Inc.Inordertoobtainserviceunderthetermsofthewarranty,BuyermustnotifyKellerAmerica,Inc.ofanydefectsbeforetheexpirationofthewarrantyperiodandmakesuitablearrangementsfortheperformanceofservices.Inallcases,BuyershallberesponsibleforpackagingandshippingtheproductstotheKellerAmerica,Inc.plantwithshippingchargesprepaid.KellerAmerica,Inc.shallpayforthereturnofanyproductstoBuyeriftheshipmentistoalocationwithinthecontinentalUSA.Buyershallberesponsibleforpayingallshippingduties,taxes,andotherchargesforproductsreturnedtoanyotherlocation.KellerAmerica,Inc.willprovideon-siteserviceonlyuponprioragreementanduponpaymentofalltravelexpensesbyBuyer.

Page10

Page 13: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

WarrantyperiodfortheLevelgage,LevelRat,Acculevel,Microlevel,Preciseline,andVal-uelineproductsis24(twenty-four)monthsfromdateofshipment.Warrantyperiodforallotherproductshereinis12(twelve)monthsfromdateofshipment.Warrantyrepaircoversallapplicablepartsandlabor.Thiswarrantyisgiveninlieuofanyotherwarranty,expressorimplied.KellerAmerica,Inc.explicitlydisclaimsanyimpliedwarrantiesofmerchantabilityandfitnessforaparticularpurpose.Therearenowarranties,expressorimplied,thatextendbeyondthedescriptionherein.ThesoleandexclusiveremedyforanyclaimsagainstKellerAmerica,Inc.shallbethewarrantydescribedinthisdocument.Alldamages,directorconsequential,limitedtothedescribedwarrantyareexcluded.

Repairs-UnlessotherwiserequestedinwritingbytheBuyer,allproductsreturnedtoKellerAmerica,Inc.underthetermsofthewarrantywillbecheckedandanalyzedinor-dertodeterminethecauseofthedefault(s)claimedbytheBuyer.AreportwillthenbesubmittedtotheBuyerpointingoutthenatureofthedefault(s),thepartyresponsibleforthedefault(s)andthequotationoftherepair,ifneeded.Forfurtherrepairinstruc-tionsgotowww.kelleramerica.com.

Complaints-AllclaimsordisputesmustbemadeinwritingtoKellerAmerica,Inc.amaximumof60daysfromreceiptofthegoods,includingdiscoveryoffaultsnotpre-viouslyapparent.Ifthewarrantyclaimsarejustified,KellerAmerica,Inc.isfreeatitsdiscretiontorepair,replaceorissuecredit.Nofurthercompensationfordamageswillbemade.

AnydisputesorclaimsofBuyermustbeinitiatedinapropercourtorotheradjudicativebody,asapplicable,withinone(1)yearfromthedateofshipmentbyKellerAmerica,Inc.,oritsrepresentative(s),orsuchclaimshallbedeemedinvalidorexpiredandcannotberenewed.Totheextentallowed,thislimitationperiodshalltrumpanyapplicablestatutorylimitationsperiodthatmaystatealongerperiod.

Limitation of responsibility -Ourresponsibilityconcernsthecorrectfunctionofourproductsonly.Itcannotbeextendedtothewholesysteminwhichtheyareused.Ourresponsibilityislimitedtothereplacement,repairorreimbursementofthegoodsweagreearedefectiveornon-conforming.Theclaimmustbeinwritingwithin60daysfromreceiptofthegoods.

Place of jurisdiction / applicable law -ThecontractmadebyacceptanceofthisoffershallbedeemedmadeintheStateofVirginiaandshallbegovernedbyandconstruedinaccordancewiththelawsofthatstatewithoutreferencetoorapplicationofanyconflictsoflawsprinciplesandwithoutconsiderationoftheplaceofexecution.BuyerexpresslyagreestothesubjectmatterandpersonaljurisdictionoftheCircuitCourtsfortheCityofNewportNews,Virginia,orthefederalDistrictCourtfortheEasternDistrictofVirginia,NewportNewsDivision.

Assignment-NeitherthisoffernoranycontractresultingtherefrommaybeassignedortransferredinwholeorpartwithoutthepriorwrittenconsentofKellerAmerica,Inc.NoassignmentortransferinviolationofthisprovisionshallbevalidorbindingonKellerAmerica,Inc.

Page11

Page 14: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

Attorney’s fees-UponanybreachofthisAgreement,thereasonableattorney’sfeesandcostsofthesubstantiallyprevailingparty,whetherbylitigationorsettlement,shallbepaid by the breaching party.

Page12

Page 15: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

X: Appendix

+ SUPPLY

OUTPUT/GROUND

2-WIRE

TRANSMITTER

POWER

SUPPLY

DISPLAY/

CONTROL

+

-

-

+

2-WIRE CURRENT LOOP

3-WIRE VOLTAGE OUTPUT

+ SUPPLY

+ OUTPUT

3-WIRE

TRANSMITTER

POWER

SUPPLY

DISPLAY/

CONTROL

+

-

-

+

GROUND

A-1

PleaserefertoSectionVII:Installationforminimumsupplyvoltageinformation.

Page 16: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

12

3

4

DRAIN/CASE GROUND

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

ECONOLINE w/ PVC CABLE...4-20mA

ECONOLINE w/mPm393...4-20mA

DRAIN/CASE GROUND

BROWN or BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

ECONOLINE w/ PUR CABLE...4-20mA

CASE

+ SUPPLY

OUTPUT/GND

VIEW OF REAR OF TRANSMITTER

ECONOLINE w/M12...4-20mA

+ SUPPLY

OUTPUT/GND

VIEW OF REAR OF TRANSMITTER

4 3

2 1

A-2

NOTES: 1: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

Page 17: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

12

3

4

DRAIN

BLACK: + SUPPLY

WHITE: GROUND

RED: + OUTPUT

ECONOLINE w/CABLE...0,5-4,5VDC

ECONOLINE w/mPm393...0,5-4,5VDC

CASE

+ SUPPLY

GROUND

VIEW OF REAR OF TRANSMITTER

+ OUTPUT

ECONOLINE w/M12...0,5-4,5VDC

+ SUPPLY

GROUND

VIEW OF REAR OF TRANSMITTER

4 3

2 1

+OUT

NOTES: 1: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

A-3

Page 18: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

VALUELINE w/ATTACHED CABLE...4-20mA

VALUELINE w/ATTACHED CABLE...0-5...10VDC

VALUELINE w/DIN43650...4-20mA

VIEW OF REAR OF TRANSMITTER

VALUELINE w/DIN43650...0-5...10VDCVALUELINE

+ OUTPUT

VIEW OF REAR OF TRANSMITTER

3

12

3

12

DRAIN

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

DRAIN

BLACK: + SUPPLY

WHITE: GROUND

RED: + OUTPUT

+ SUPPLY

OUTPUT/GROUND

SEE NOTE 1.

+ SUPPLY

GROUND

A-4

Page 19: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

AB

CD

E

F

AB

CD

E

F

+ SUPPLY

OUTPUT/GROUND

VALUELINE W/MIL-C-26482...4-20mA

REAR VIEW OF TRANSMITTER

VALUELINE W/MIL-C-26482...0-5...10VDC

+ SUPPLY

GROUND

+ OUTPUT

REAR VIEW OF TRANSMITTER

E: DRAIN

A-5

NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

Page 20: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

BLUE: RS485A

YELLOW: RS485B

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: GROUND

RED: + OUTPUT

BLUE: RS485A

YELLOW: RS485B

PRECISELINE w/ATTACHED CABLE...4-20mA + RS485

PRECISELINE w/ATTACHED CABLE...0-5...10VDC + RS485

DRAIN (NOTE 1)

BLACK: GROUND

WHITE: SDI-12

RED: + VCC

BLUE: RS485A

YELLOW: RS485B

PRECISELINE SDI w/ATTACHED CABLE...SDI-12+ RS485

A-6

NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

Page 21: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

PRECISELINE w/MIL-C-26482...4-20mA + RS485

REAR VIEW OF TRANSMITTER

PRECISELINE w/MIL-C-26482...0-5...10VDC + RS485

REAR VIEW OF TRANSMITTER

A: + SUPPLY

C: OUTPUT/GROUND

A: + SUPPLY

C: GROUND

B: + OUTPUT

D: RS485A

F: RS485B

D: RS485A

F: RS485B

E: DRAIN

AB

CD

E

F

AB

CD

E

F

PRECISELINE SDI w/MIL-C-26482...SDI-12 + RS485

REAR VIEW OF TRANSMITTER

A: + SUPPLY

C: GROUND

B: SDI-12F: RS485B

D: RS485A

AB

CD

E

F

A-7

NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

Page 22: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

NOTES: 1: FOR LIGHTNING/SURGE PROTECTION TO BE EFFECTIVE, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. 2: LIGHTNING PROTECTION NOT AVAILABLE ON ECONOLEVEL. DRAIN WIRE CONNECTION NOT REQUIRED. 3: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

LEVELGAGE & ECONOLEVEL w/ATTACHED CABLE...4-20mA

LEVELGAGE w/ATTACHED CABLE...0-5...10VDC

ACCULEVEL & LEVELRAT w/ATTACHED CABLE...4-20mA + RS485

ACCULEVEL & LEVELRAT w/ATTACHED CABLE...0-5...10VDC + RS485

DRAIN (NOTE 1,2)

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: GROUND

RED: + OUTPUT

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

BLUE: RS485A

YELLOW: RS485B

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: GROUND

RED: + OUTPUT

BLUE: RS485A

YELLOW: RS485B

A-8

Page 23: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

NOTES: 1: FOR LIGHTNING/SURGE PROTECTION TO BE EFFECTIVE, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.

MICROLEVEL & NANOLEVEL w/ATTACHED CABLE...4-20mA + RS485

DRAIN (NOTE 1)

BLACK: + SUPPLY

WHITE: OUTPUT/GROUND

BLUE: RS485A

YELLOW: RS485B

DRAIN (NOTE 1)

BLACK: GROUND

WHITE: SDI-12

RED: + VCC

BLUE: RS485A

YELLOW: RS485B

ACCULEVEL SDI w/ATTACHED CABLE...SDI-12+ RS485

A-9

Page 24: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

A-10

MINIMUM PIPE BEND RADIUS

Acculevel/ LevelgageØ0.83”

MicrolevelØ0.63”

Schedule40

1”IPS(Ø1.315x0.133”w) 22” 18”

1.5”IPS(Ø1.900”x0.145”w) 4” 5”

2”IPS(Ø2.375x0.154”w) 3” 3”

Schedule80

1”IPS (Ø1.315x0.179”w) 22” 22”

1.5”IPS(Ø1.315x0.200”w) 4” 6”

2”IPS(Ø2.375x0.218”w) 4” 4”

Page 25: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

A-11

Page 26: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Keller America Inc User’s Guide Rev. 07/20

A-12

Signal cable

Transmitter

Vent tube

Bellows Assembly

Drying Tube Assembly

VENT TUBE TERMINATION - DRYING TUBE OR BELLOWS

Remove yellowcap after installation

NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DRYING TUBE ASSEMBLY - CLEAR TUBE FILLED WITH INDICATING DESICCANT, ATTACHES DIRECTLY TO CABLE VENT TUBE, INTERCEPTS WATER VAPOR. HIGHLY RECOMMENDED WHEN OPERATING IS IN HIGH HUMIDITY CONDITIONS. MUST BE PERIODICALLY RENEWED AS DESICCANT BECOMES SATURATED, TURNING COLOR FROM BLUE (DRY) TO PINK (SATURATED). REMOVE YELLOW CAP FROM FREE END AFTER INSTALLATION. 3: BELLOWS ASSEMBLY - ALTERNATIVE TO THE DRYING TUBE, THIS ANEROID BELLOWS ATTACHES TO CABLE VENT TUBE AND REQUIRES NO PERIODIC MAINTENANCE. RECOMMENDED WHERE A SLIGHT SACRIFICE IN ACCURACY CAN BE TOLERATED.

Page 27: Keller America Inc User s Guide Rev. 02/20 · Keller America Inc is the North American subsidiary of Keller AG für Druckmesstechnik, which continues as the leader in level and pressure

Electronic copies of this user’s guide can be found at kelleramerica.com

BORN SWISS · MADE AMERICAN · KELLERAMERICA.COM