Top Banner
creating expressive ceilings  www.danoline.com Expressive gypsum ceilings
132

KATALOG DANOLINE

Oct 15, 2015

Download

Documents

prihananto_sa

KATALOG DANOLINE
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 5/25/2018 KATALOG DANOLINE

    1/132

    creating expressive cei l ings

    w w w . d a n o l i n e . c o m

    Expressivegypsumceilings

  • 5/25/2018 KATALOG DANOLINE

    2/132

    C o n t e n t s

    PrefaceDanoline, history, possibilities Page 3

    ProductsSUSPENDED CEILINGS

    Contur 600 Page 12

    Linear 600 Page 16

    Markant 500 and 600 Page 20

    Belgravia 600 Page 26

    Plaza 600 Page 30

    Danoline tiles 600, White and Metallic Page 34

    Danoline tiles 600, Medley Page 36

    ACCESSORIES

    Danopor Page 40

    SELF-SUPPORTING CEILINGS

    Corridor 300 Page 42

    Corridor F30 Page 46

    Corridor Swing 600 Page 50

    LININGS

    Danopanel Page 54

    Combipanel Page 58

    Designpanel 900 and 1200 Page 62

    Tectopanel Page 66

    Contrapanel Page 70

    Kinopanel Page 74

    DESIGNELEMENTS

    Curvex Page 78

    Mitex Page 80

    Solopanel and Stratopanel Page 82

    Properties

    SURFACING

    Gypsum as a natural palette Page 88

    ACOUSTICS

    Gypsum regulates sound Page 90

    FIRE

    Gypsum as natures sprinkler Page 98

    INDOOR CLIMATE AND ENVIRONMENT

    Gypsum can breathe Page 100

    LOAD-BEARING CAPACITY AND WEIGHT

    Gypsum as a weightlifter Page 102

    MOISTURE

    Gypsum as a natural skin Page 104

    LUMINOUS REFLECTANCE

    Gypsum mirrors the light Page 106

    PerforationsPerforations and patterns Page 111

    Globe, G Page 112Quadril, Q Page 113

    Micro, M Page 114

    Designpanel Page 115

    Cleaning and maintenanceSuspended and Self-supporting ceilings Page 118

    Ceiling linings, acoustic and plain Page 119

    SummarySuspended ceilings Page 122

    Linings Page 124

    Self-supporting ceilings Page 126

    Designelements Page 127

    Accessories Page 128

    H o w t o u s e t h e i n d e x

    All information in the index is ge neral directions about the Danoline products. There may be project-specific details which

    have not been accounted for. It is a foregone conclusion that users of Danoline data have technical building skills and that

    t hey have t he u sual p ro je c t r e sponsi bi li ty . In fo rmat ion on our web si te w w w . d a n o l i n e . c o m i s always up to dat e

    and applicable. Our technical service department is always at your disposal with further information and guidance.

  • 5/25/2018 KATALOG DANOLINE

    3/132

    The difference between the ordinary and the unique may

    lie in the tiny details. The obser vers feeling of harmony

    in a building, the surprise when his eye spots a solution

    that is slightly more beautiful than expected at first sight.

    Architecture is impressive when functionality blends with

    aesthetics and form a perfect whole.

    All the elements of a building must form integral parts

    of the whole, allowing the expression of the architects

    language of form and original intention. The ceili ng must

    be characterised as a not quite inessential feature of the

    whole building. When dealing with plaster board ceilings

    Danolines multiple resources are at your disposal any

    time. We are pleased to offer you a developing partnershipany time to help you achieve your specifications and meet

    your wishes in terms of architectonic solutions. If you

    think Danoline as early as in the ini tial concept, you will

    benefit most from our experience and technical know-how.

    We are competent sparring partners who create i ndividual

    products. Helping you turn your creative conceptions into

    implementible solutions would be a pleasure to us.

    Plaster is a flexible material which can easi ly be moulded.

    In the Danoline ceilings we take advantage of the

    mouldable properties of the material by punching holes

    and patterns which add a different dimension of aesthetics

    to the plaster. At the same time this material offers a

    number of good properties which in their manner add to

    the building.

    Y o u r w a y s o f c r e a t i n g e x p r e s s i v e c e i l i n g s m a d e o f p l a s t e r b o a r d p a n e l s s t a r t h e r e

    Plaster gives good opportunities for creating speci al/unique

    solutions that meet your specifications and wishes as to

    ceiling expression. At Danoline we stress continuous product

    development to ensure that we meet the continuous

    requirements of beautiful and persuasive solutions.

    Plasterboards for the manufacture of Danoline ceilings

    have been developed by Knauf Danogips, the leading

    Scandinavian producer of plasterboards. Danoline s and

    Knauf Danogips efforts within product development and

    production have secured our position as partners to any

    type of building project in Northern Europe.

    3

  • 5/25/2018 KATALOG DANOLINE

    4/1324

  • 5/25/2018 KATALOG DANOLINE

    5/1325

    1165

  • 5/25/2018 KATALOG DANOLINE

    6/132

    1165:

    Architect: Semren Arkitektkontor, Gteborg

    Project: Ungdoms bolig, Gteborg - Sweden

    Product: Designpanel 1200

    F o r g o o d r e a s o n s p l a s t e r h a s b e e n t h e p r e f e r r e d m a t e r i a l f o r c e i l i n g s f o r c e n t u r i e s

    Plaster forms a natural part of modern building design,

    but as a material it dates back in history. For centuries

    plaster has been used to meet both functional and aesthetic

    requirements of buildings. Plaster has been used in as

    different places as decorative ceilings in the beautiful

    Italian and French Renaissance palaces as for the pyramids

    in Pharaonic Egypt. Wherever it has been used, builders

    have had the ability to exploit its characteristic properties

    to create outstanding results.

    The method used to process gypsum is quite simple, and

    this is the most essential reason why it was known as a

    building material way back. The use of plaster found favour

    in earnest in the antique Roman culture around the year

    0 A.D. At that time many buildings were made in marble

    and then covered with a thin coat of plaster and painted

    in bright colours. At the same time the great flexibil ity

    and mouldability of the plaster meant that this material

    was widely used for stuccowork inside buildings. Plaster is

    suitable for detailing, and it was therefore used for the fine

    and artistic ornamentation and embellishments on walls and

    ceilings, which may be seen in Italian Baroque and Rococo

    architecture. This material allowed for the cre ation of

    reliefs and ornamentation which had an outstanding impact

    on the rooms, whereas their weight was unsubstantial.

    In year 1775 French Lavoisier found the chemical formulafor gypsum which paved the way for industrial processing

    of the material. Plaster is made from the gypsum stone

    mineral which is found naturally in Germany, France and

    Italy. Gypsum stone is converted into burnt gypsum via

    heating, crushing and mixing with water. The material then

    solidifies in the shape which it is in.

    6

  • 5/25/2018 KATALOG DANOLINE

    7/1327

  • 5/25/2018 KATALOG DANOLINE

    8/132

    1290

    1276 1157

    8

  • 5/25/2018 KATALOG DANOLINE

    9/132

    1276:

    Architect: Erik Eriksen, Grlse

    Project: Daginstition, Maglekrvej, Grlse - Denmark

    Product: Danopanel - G1, R

    1157:

    Architect: MA Arkitekter, Bors

    Project: Hgskolan i Bors- Sweden

    Product: Corridor Swing 600 - Q1

    1290:

    Architect: S og I arkitekter

    Project: OBH Gruppen, Odense - Denmark

    Product: Contur 600 - M1 , Designpanel 900 - M1F

    1287:

    Architect: Hune & Elkjr

    Project: Korsvang, Assens - Denmark

    Product: Tectopanel - G1

    1284:

    Architect: Rudolf Lolk A/S

    Project: Arkitektfirmaet Rudolf Lolk A/S, Esbjerg - Denmark

    Product: Designpanel 1200 - M1F

    1137:

    Architect: Wingrd Arkitekt kontor

    Project: Astra Zeneca tnghuset, Gteborg - Sweden

    Product: Mitex - R

    N o w o u r e x t e n s i v e a s s o r t m e n t o f p l a s t e r b o a r d p a n e l s a f f o r d s

    e n d l e s s d e s i g n o p t i o n s

    Smooth surfaces and clean lines are characteri stics

    of contemporary beautiful, minimalist buildings and

    the simplistic expression of the plaster contri butes to

    architectonic clarity. It is possible to cr eate elements which

    recede into the background and do not distract attention

    from the architectonic expression of the r oom. With plaster

    the strict and minimalist expression is preserved and the

    extensive mouldability of the material also affords wide

    opportunities for creating individual solutions with a high

    degree of detailing.

    The great flexibility of the material, means that

    functionality and aesthetics can form a synthesis so the

    finish of the room becomes just as intended. With Danolineceilings there are infinite combinations of expressions,

    as the surface of the plaster allows for the application

    of many types of paint, foils or punchings, so it may be

    adapted fully to the expression of the room.

    Beside the evident aesthetic advantages of using plaster,

    this material also offers a number of other properties which

    contribute favourably to the building. Gypsum is a natural

    material with a long life and it is environmentally friendly.

    Plaster can emit and adsorb vapour which makes it play

    an important part if the building is to have a good indoor

    climate.

    Plaster also affords good acoustic properties. The different

    types of perforation offer varying properties in the form of

    sound absorption and reflection, in this way ceiling panels

    can tune the room and render fine acoustic conditions . The

    reflection of light is also easily i nfluenced by the use of

    plaster as the surface structure appears highly varied and

    with different reflective properties, depending on the type

    of paint applied.

    1137

    1284

    1287

    9

  • 5/25/2018 KATALOG DANOLINE

    10/132

  • 5/25/2018 KATALOG DANOLINE

    11/132

    Products

    1149

  • 5/25/2018 KATALOG DANOLINE

    12/13212

    1324

  • 5/25/2018 KATALOG DANOLINE

    13/13213

    Contur gives the appearance of a monolithic surface

    finished with fine line markings. The perforations on Contur

    appear more distinctly than on other types of ceilings

    and aesthetically, therefore, will accentuate the acoustic

    solution selected.

    Choosing fixed dados, arches or folded plaster achieves

    an elegant framework to the ceiling. Contur produces a

    concealed grid appearence, and is similar to Danopanel and

    Tectopanel.

    E x p r e s s i o n a n d a c o u s t i c s e n h a n c e d b y t h e s u b t l e p e r f o r a t i o n o n C o n t u r

    1149:

    Architect: Liljewall Arkitekter, Gteborg

    Project: Biotechhuset, Gteborg - Sweden

    Product: Designpanel 900 - M2F

    1324:

    Architect: Dall & Lindhardtsen

    Project: Nrum Gymnassium - Denmark

    Product: Contur 600 - G1

    1278:

    Architect: Dall & LindhardtsenProject: Holbk Sygehus - Denmark

    Product: Contur 600 - G1

    1223:

    Architect: Sisustusarkkitehdit Gullstn-Inkinen Oy

    Project: Teknos Oy, Rajamki, paint factry - Finl and

    Product: Contur 600 - G1

    Contur 600

    1223

    12781324

  • 5/25/2018 KATALOG DANOLINE

    14/132

    600

    Max.600

    600

    Max.600

    600 1200

    14

    S u s p e n s i o n s y s t e m

    The spacer bars shall be fixed max. 100 mm from the

    hangers. At joints of main T-runners, hangers shall be fixed.

    The suspension hanger must be fixed to the main r unner

    at 1500 mm centres and not less than 100 mm from the

    wall angle.

    Measurements are in mm.

    Drawing no.: 10

    D e t a i l

    Cross section 4,Contur 600, with shadow edge tr im.Drawing no.: 10.2.006

    Cross section 3,Contur 600, with shadow edge tr im.Drawing no.: 10.2.005

    Longitudinal section,Contur 600, with shadow edge tr im.

    Drawing no.: 10.2.004

    Longitudinal section,Contur 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.003

    Cross section 2,Contur 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.002

    Cross section 1,Contur 600 with painted fix fr ieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.001

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 600 x 12.5 mm

    625 x 625 x 12.5 mm

    Other sizes on request.

    D r a f t s p e c i f i c a t i o n

    Danoline Contur 600, M1, 600 x 600 x 12.5 mm,

    White painted as standard, for concealed 24 mm

    suspension systems.

  • 5/25/2018 KATALOG DANOLINE

    15/13215

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    C o m p o n e n t s

    MAIN RUNNER

    Part no.

    85030W x L x H

    24 x 3600 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    SPACER BAR

    Part no.

    8260013

    8269913

    L

    600

    300

    SHADOW LINE

    EDGE TRIM

    Part no.

    1459

    W x L x H

    12 + 19 x 3050 x 10 + 24

    WALL ANGLE

    Part no.

    1438

    W x L x H

    19 x 3050 x 32

    I n s t a l l a t i o n

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they shouldbe screwed to the soffit. It isimportant that the suspensionis plumb. The main runners arefixed parallel at 300 mm or 600

    mm centres.

    C h e c k i n g t h es u s p e n s i o n s y s t e ma n d s p a c e r b a r When the suspension systemis installed, the levels and

    angles should be checked andif necessary the hangers adjusted.The spacer bar should be installedat a maximum of 100 mm fromthe hangers and with a distanceof max. 1500 mm c/c.

    W a l l T r i m The wall angle should be fixedat max. 300 mm centres. Atcorners the tr im should be mitredaccurately.

    M a i n r u n n e r The suspension hanger must befixed to the main runner at 1500mm centres and not less than100 mm from the wall angle.

    T i l e s The level of the tiles should bechecked when the installation iscompleted.Gloves should be worn at all

    times when handling the tiles anda saw or knife used to cut thetiles to size.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    J o i n i n g t h e M a i nR u n n e r s The main runners haveinterlocking tongues at bothends enabling them to be joined

    together, an additional hangermust be used at this point.

    Contur 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    16/13216

    1124

  • 5/25/2018 KATALOG DANOLINE

    17/13217

    Linear is perceived as floating, self-contained panels,

    defined by sharp, almost navigationally con tinuous

    alignments. Diagonal to the alignments, the ceiling gives

    the appearance of large interconnected surfaces. Th e ceiling

    is wellsuited to renovating existing ceilings and on account

    of its styling is very simple to mount and demount. Linear

    almost covers the grid system. This has the advantage of

    concealing old grid.

    The option of having an installation height of just 63

    mm ensures greater floor-to-ceiling hei ght, thus providing

    improved space for engineering installations. In addition,

    the ceiling can be painted while actually in the rail system.

    The design and assembly clips prevent the board frombeing pushed up out of the rail system during cleaning and

    painting.

    G e o m e t r i c a l c h a r a c t e r i s t i c s e m p h a s i z e d b y t h e s h a r p e d g e s o f t h e i n d i v i d u a l L i n e a r b o a r d

    1124:

    Architect: KHR ArkitekterProject: Arlanda Pir F/5:an - Arlandaflygplats - Sweden

    Product: Linear 600 - M1

    0950:

    Architect: CF Mller

    Project: Vejle Sygehus - Denmark

    Product: Linear 600 - G1

    Linear 600

    0950

    09500950

  • 5/25/2018 KATALOG DANOLINE

    18/132

    600

    Max.600

    600

    Max.600

    6001200

    18

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 600 x 12.5 mm

    D r a f t s p e c i f i c a t i o n ,

    Danoline Linear 600, M1, 600 x 600 x 12.5 mm,

    White painted as standard, for exposed 24 mm suspension

    systems.

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 600 mm, and shall be made

    from 1200 mm cross-Tee. The suspension hanger must be

    fixed to the main runner at 1200 mm centres and not le ss

    than 400 mm from the wall angle.

    Danoline recommends the use of suspension systems with

    straight connections between main runners and cro ss tees,

    so any differences in levels are avoided, i.e. the suspension

    systems components are all at the same level.

    Measurements are in mm.

    Drawing no.: 15

    D e t a i l

    Linear 600, with fr ieze of Plaza 600 Regula, plain.

    Drawing no.: 15.2.004

    Linear 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 15.2.005

    Linear 600, with intermediate fr ieze of Plaza 600 Regula.

    Drawing no.: 15.2.008

  • 5/25/2018 KATALOG DANOLINE

    19/13219

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    85030

    W x L x H

    24 x 3600 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    85130

    85230

    85430

    W x L x H

    24 x 300 x 38

    24 x 600 x 38

    24 x 1200 x 38

    SHADOW LINE

    EDGE TRIM

    Part no.

    1459

    W x L x H

    12 + 19 x 3050 x 10 + 24

    WALL ANGLE

    Part no.1420

    W x L x H24 x 3050 x 24

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The wall angle should be fixedat max. 300 mm centres. Atcorners the tr im should be mitredaccurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.Note: The underside of thefinished ceiling will be 11 mmlower than the underside of the

    wall tr im.

    S u s p e n s i o n H a n g e r s The adjustable hangers should befixed with eye screws, brackets orsimilar. If direct hangers are usedthey should be screwed to thesoffit. Start with the first hangernot more than 400 mm from thewall in the longitudinal directionof the main runner, and then at a

    maximum of 1200 mm centres.If additional f ixtures are fixedto the suspension system, extrahangers should be used.

    M a i n r u n n e r The profiles are fixed in parallelwith centres of 1200 mm, or600 mm. The main runners haveinterlocking tongues in both

    ends and can therefore be lockedtogether.

    C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect slot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The tiles are fitted into the system from below, with an upwardmovement.Slide in one side of the tile until it is supported by the grid, bring thetile level and then slide in the opposite side.

    To demount ti les apply upward pressure. Slide the tile out, move itforward, to the side and then let the tile drop below.Gloves should be worn at all times when handling the tiles and a saw orknife used to cut the tiles to size.

    Linear 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    20/13220

    1269

  • 5/25/2018 KATALOG DANOLINE

    21/13221

    Markant is the classic ceiling solution, featuring str ong

    shaded markings between ceiling panels.

    The ceiling will often be se en fitted into a pattern adapted

    to the shape of the room, thus achieving a lightness and

    dynamic of design.

    The bevelled edges of the ceili ng panels ensure easy,

    straightforward assembly, and combined with r ecessing into

    the suspension system this provides a directionally stable

    ceiling.

    C l a s s i c a l c e i l i n g s o l u t i o n a c h i e v e d w i t h M a r k a n t ,6 0 0 m o d u l e s a l l o w u p g r a d i n g t o s w i n g f u n c t i o n

    1269:

    Architect: Dissing og Weitling

    Project: Rdhusparken, Glostrup - Denmark

    Product: Markant 600 - M1

    9999:

    Architect: Interoc, StockholmProject: Konferensrum Interoc, Stockholm - Sweden

    Product: Markant 600, Swing

    0990:

    Architect: Fich og Bengaard

    Project: Knud Engsig A/S, Aalborg - Denmark

    Product: Markant 500 - G1

    Markant 500 and Markant 600

    0990

    99999999

  • 5/25/2018 KATALOG DANOLINE

    22/132

    600

    Max.600

    600

    Max.600

    6001200

    22

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations..

    P r o d u c t

    Sizes

    600 x 600 x 12.5 mm

    600 x 1200 x 12.5 mm

    625 x 625 x 12.5 mm

    625 x 1250 x 12.5 mm

    Other sizes on request.

    600 x 600 x 12.5 with swing function, S24

    D r a f t s p e c i f i c a t i o n ,

    Danoline Markant 600, G1, 600 x 600 x 12.5 mm,

    (12.5 x 610 x 610 mm) White painted as standard,

    for exposed suspension systems 15/24 mm for module

    600 (24 mm for module 610).

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 600 mm, and shall be made

    from 1200 mm cross-Tees. The suspension hanger must be

    fixed to the main runner at 1200 mm centres and not le ss

    than 400 mm from the wall angle.Measurements are in mm.

    Drawing no.: 20

    D e t a i l

    Markant 600, with fr ieze of Plaza 600 Regula.

    Drawing no.: 20.2.003

    Markant 600, with wall tr im.

    Drawing no.: 20.2.011

    Markant 600, with shadow edge trim.

    Drawing no.: 20.2.004

    Markant 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 20.2.002

  • 5/25/2018 KATALOG DANOLINE

    23/13223

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    85030

    W x L x H

    24 x 3600 x 38

    MAIN RUNNER

    Part no.

    750030

    W x L x H

    15 x 3000 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    85130

    85230

    85430

    W x L x H

    24 x 300 x 38

    24 x 600 x 38

    24 x 1200 x 38

    CROSS TEE

    Part no.

    751130

    751230

    751430

    W x L x H

    15 x 300 x 38

    15 x 600 x 38

    15 x 1200 x 38

    WALL ANGLE

    Part no.

    1420

    W x L x H

    24 x 3050 x 24

    WALL ANGLE

    Part no.

    1438

    W x L x H

    19 x 3050 x 32

    SHADOW LINE

    EDGE TRIMPart no.

    1459

    W x L x H10 + 24 x 3050 x 12 + 19

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and

    then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.

    C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the

    tiles and a saw or knife used tocut the tiles to size.

    M a i n r u n n e r The main runners are installedparallel to each other at distances1200 mm, or 600 mm, c/cdepending on system module.

    The main runners haveinterlocking tongues in both ends,and can be locked together.

    Markant 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    24/132

    500

    Max.500

    500

    Max.500

    5001000

    24

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    500 x 500 x 9.5 mm

    D r a f t s p e c i f i c a t i o n ,

    Danoline Markant 500, G1, 500 x 500 x 9.5 mm,

    White painted as standard, for exposed 15 mm suspension

    systems.

    Measurements are in mm.

    Drawing no.: 25

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 500 mm, and shall be made

    from 1000 mm cross-Tees. The suspension hanger must be

    fixed to the main runner at 1000 mm centres and not le ss

    than 400 mm from the wall angle.

    D e t a i l

    Markant 500 with perimeter of cut Markant Regula.

    Drawing no.: 25.2.001

    Markant 500 with perimeter of Plaza Regula.Drawing no.: 25.2.002

  • 5/25/2018 KATALOG DANOLINE

    25/13225

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    750010

    W x L x H

    15 x 3000 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    751210

    751410

    W x L x H

    15 x 500 x 38

    15 x 1000 x 38

    WALL ANGLE

    Part no.

    1438

    W x L x H

    19 x 3050 x 32

    SHADOW LINE

    EDGE TRIM

    Part no.1459

    W x L x H

    12 + 19 x 3050 x 10 + 24

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300mmcentres. At corners the angleshould be mitred accurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and

    then at a maximum of 1000mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.

    C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the

    tiles and a saw or knife used tocut the tiles to size.

    M a i n r u n n e r The main runners are installedparallel to each other at distances1000 mm, or 500 mm c/cdepending on system module.

    The main runners haveinterlocking tongues in both ends,and can be locked together.

    Markant 500

    A A

  • 5/25/2018 KATALOG DANOLINE

    26/13226

    1201

  • 5/25/2018 KATALOG DANOLINE

    27/13227

    Belgravia is the ceiling with a grid system that is semi-

    recessed. Supplied with tegular and bevelled edges, the

    tiles guarantee a very directionally stable ceilin g and are

    less sensitive to damaging the edges.

    As they are being installed, they fall into place in the

    suspension system with distinct ease and simplicity.

    E a s y a n d e f f o r t l e s s p e r f o r m a n c e s e c u r e d b y t h e g e o m e t r i c a l c h a r a c t e r i s t i c s o f B e l g r a v i a

    1201:

    Architect: Arkkitehtitoimisto Larkas & Laine Oy

    Project: Kontor bygning, Outokumpu - Finland

    Product: Belgravia 600 - Stardust

    1198:

    Architect: Suunnittelukeskus OyProject: Sygehus, Kerava - Finland

    Product: Belgravia 600

    1131:

    Architect: MA Arkitekter Bors

    Project: hlenshuset, Bors - Sweden

    Product: Belgravia 600 - M1

    Belgravia 600

    1131

    1198

  • 5/25/2018 KATALOG DANOLINE

    28/132

    600

    Max.600

    600

    Max.600

    6001200

    28

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 600 x 12.5 mm

    625 x 625 x 12.5 mm

    D r a f t s p e c i f i c a t i o n

    Danoline Belgravia 600, M1, 600 x 600 x 12.5 mm, (610

    x 610 x 12.5 mm) white painted as standard, for exposed

    suspension systems 15 mm system for module 600 (24

    mm system for module 610).

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 600 mm, and shall be made

    from 1200 mm cross-Tees. The suspension hanger must be

    fixed to the main runner at 1200 mm centres and not le ss

    than 400 mm from the wall angle.

    D e t a i l

    Belgravia 600, with shadow line edge tr im - S15

    Drawing no.: 22.2.004

    Belgravia 600, with shadow line edge tr im - S24

    Drawing no.: 22.2.005

    Measurements are in mm.

    Drawing no.: 22

  • 5/25/2018 KATALOG DANOLINE

    29/13229

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    750030

    W x L x H

    15 x 3000 x 38

    MAIN RUNNER

    Part no.

    85030

    W x L x H

    24 x 3600 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    751130

    751230

    751430

    W x L x H

    15 x 300 x 38

    15 x 600 x 38

    15 x 1200 x 38

    CROSS TEE

    Part no.

    85130

    85230

    85430

    W x L x H

    24 x 300 x 38

    24 x 600 x 38

    24 x 1200 x 38

    WALL ANGLE

    Part no.

    1438

    Bx L x H

    19 x 3050 x 32

    WALL ANGLE

    Part no.

    1420

    Bx L x H

    24 x 3050 x 24

    SHADOW LINE

    EDGE TRIMPart no.

    1466

    W x L x H15 + 15 x 3050 x 8 + 25

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are painted

    in CMC 001 Global white

    (equivalent to NCS 0902

    G48Y). Suspension grid

    available in ultraline, contact

    technical department.

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this also makes

    installation quicker and easier. It will also be easier to carry o ut inspections to installations above the ceiling as removal of the

    tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and

    then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.

    C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the

    tiles and a saw or knife used tocut the tiles to size.

    M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending on system module.

    The main runners haveinterlocking tongues in both ends,and can be locked together.

    Belgravia 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    30/13230

    1317

  • 5/25/2018 KATALOG DANOLINE

    31/13231

    The setting of a Plaza ceiling is maybe best highlighted by

    using a narrow gr id system.

    Plaza 600 is fast and easy to mount and adapt, as all

    edges remain hidden above the grid system.

    Plaza 600 is often used as a frieze/margin panel for

    Markant and Linear. Plaza 600 combines the qualities of

    gypsum with favourable pricing.

    P l a z a i s t h e s i m p l e d e s i g n w h i c h c a n b ec o m b i n e d w i t h c o n s i s t e n t p e r f o r a t i o n s

    1317:

    Architect: Initiative in DesignProject: Sir Williams Perkins School - UK

    Product: Plaza 600 - M1

    1210, 1211, 1212:

    Architect: H & M Arkkitehdit Oy

    Project: School Veikkola - Finland

    Product: Plaza 600 - M1

    Plaza 600

    1212

    1210

    1211

  • 5/25/2018 KATALOG DANOLINE

    32/132

    600

    Max.600

    600

    Max.600

    6001200

    32

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 600 x 9.5 mm

    600 x 1200 x 9.5 mm

    600 x 600 x 12.5 mm

    600 x 1200 x 12.5 mm

    625 x 625 x 12.5 mm

    625 x 1250 x 12.5 mm Other sizes on request.

    D r a f t s p e c i f i c a t i o n ,

    Danoline Plaza 600, M1, 600 x 600 x 9.5 mm,

    (610 x 610 x 9.5 mm) White painted as standard, for

    exposed suspension systems 15/24 mm system for module

    600 (15/24 mm system for module 610)

    Measurements are in mm.

    Drawing no.: 30

    D e t a i l

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 600 mm, and shall be made

    from 1200 mm cross-Tees. The suspension hanger must be

    fixed to the main runner at 1200 mm centres and not le ss

    than 400 mm from the wall angle.

    Danoline recommends the use of suspension systems with

    straight connections between main runners and cro ss tees,

    so any differences in levels are avoided, i.e. the suspension

    systems components are all in the same level.

    Plaza 600 with wall tr im.

    Drawing no.: 30.2.001

    Plaza 600 with shadow line edge tr im.

    Drawing no.: 30.2.002

  • 5/25/2018 KATALOG DANOLINE

    33/13233

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    750030

    W x L x H

    15 x 3000 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    751130

    751230

    751430

    W x L x H

    15 x 300 x 38

    15 x 600 x 38

    15 x 1200 x 38

    WALL ANGLE

    Part no.

    1438

    Bx L x H

    19 x 3050 x 32

    SHADOW LINE

    EDGE TRIMPart no.

    1459

    W x L x H12 + 19 x 3050 x 10 + 24

    Alternative suspension S24 see Markant 600.

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and

    then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.

    C r o s s - T e e s The Cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the Cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the

    tiles and a saw or knife used tocut the tiles to size.

    M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending on system module.

    The main runners haveinterlocking tongues in both ends,and can be locked together.

    Plaza 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    34/13234

    1300

    1306 1321

  • 5/25/2018 KATALOG DANOLINE

    35/13235

    Danoline Tiles are mounted with a visible Lay-in grid system.

    The ceiling panels look like a smooth, white faced surface,

    which is environmentally friendly and ensures gre at usability

    in rooms with re latively high humidity.

    The surface is easy to maintain and will therefore withstand

    rough washing, as it has a good mechanical resistance.

    Apart from Danoline Tiles fine qualities, it is also an

    economically advantageous solution.

    D u r a b l e s u r f a c e s a n d g o o d e c o n o m y a c c o m p l i s h e d w i t h t h e s i m p l e p r o d u c t D a n o l i n e T i l e s

    1306:

    Architect: Aukett Ltd, London

    Project: SAS Radisson, Stansted, - UKProduct: Danoline Tiles 600 - White

    1321:

    Architect: Bluestone

    Project: ABL Factory/ warehouse - UK

    Product: Danoline Tiles 600 - White

    1300:

    Architect: Kinnersley Kent Design, London

    Project: House of Fraser, Croydon, Surrey - UK

    Product: Danoline Tiles 600 - White

    1119:

    Project: Close up

    Product: Danoline Tiles 600, White

    1120:Project: Close up

    Product: Danoline Tiles 600, Metallic

    1122:

    Architect: Arkitektkontoret Waage as, Bergen

    Project: Amficenter Voss, Bergen - Norway

    Product: Danoline Tiles 600, Metallic

    Danoline Tiles 600, White and Metallic

    1122

    11201119

  • 5/25/2018 KATALOG DANOLINE

    36/13236

    1109

  • 5/25/2018 KATALOG DANOLINE

    37/13237

    Danoline Tiles Medley is mounted in a visible Lay-in grid

    system. The tiles are available with squared or rebated

    edges.

    The ceiling tiles appear like a smooth tinted laminated

    surface. It is environmentally friendly and ensures gr eat

    usability in rooms with relatively high humidity.

    The surface is easy to maintain as it can withstand rough

    washing, because of the good mechanical resistance in

    the surface. Danoline Tiles Medley offers good i nherent

    properties and it is also an economically advantageous

    solution.

    P e r f o r a t e d D a n o l i n e T i l e s M e d l e y c o m p l e t e w i t h e d g e d e t a i l s a n d f o i l s u r f a c e

    1109, 1111, 1114, 1117:

    Architect: Villum Kirkegaard

    Project: Kontor, Hobro - Denmark

    Product: Danoline Tiles 600 - Medley

    Danoline Tiles 600, Medley

    1114

    11171111

  • 5/25/2018 KATALOG DANOLINE

    38/132

    600

    Max.600

    600

    Max.600

    6001200

    38

    S u r f a c e

    Regula R, Laminated white, metallic and medley

    foil. Medley is also available with Globe G1

    perforation.

    P r o d u c t

    S i z e s

    600 x 600 x 6.5 mm

    600 x 1200 x 6.5 mm

    600 x 600 x 9.5 mm

    600 x 1200 9.5 mm

    625 x 625 x 9.5 mm

    Other sizes on request.

    D r a f t s p e c i f i c a t i o n ,

    Danoline Danoline Tiles 600, R, 600 x 600 x 6.5 mm,

    Laminated type white 600 x 600 x 6.5 mm for exposed

    15/24 mm suspension systems

    Measurements are in mm.

    Drawing no.: 40

    D e t a i l

    Danoline Tiles 600 with wall tr im.Drawing no.: 40.2.001

    Danoline Tiles 600 with shadow line edge tr im.

    Drawing no.: 40.2.002

    S u s p e n s i o n s y s t e m

    Cut cross-Tees may not exceed 600 mm, and shall be made

    from 1200 mm cr oss-T ees. The suspension hanger must be

    fixed to the main run ner at 1200 mm centres and not less than

    400 mm from the wall angle.

    Danoline recommends the use of suspension systems with

    straight connections between main runners and cro ss tees,

    so any differences in levels are avoided, i.e. the suspension

    systems components are all in the same level.

    E d g e

    A

    A

    A / E - Medley G1 and R

    A

    A

  • 5/25/2018 KATALOG DANOLINE

    39/13239

    C o m p o n e n t s

    I n s t a l l a t i o n

    MAIN RUNNER

    Part no.

    750030

    W x L x H

    15 x 3000 x 38

    ADJUSTABLE HANGERS

    Part no. Length

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    CROSS TEE

    Part no.

    751130

    751230

    751430

    W x L x H

    15 x 300 x 38

    15 x 600 x 38

    15 x 1200 x 38

    WALL ANGLE

    Part no.

    1438

    Bx L x H

    19 x 3050 x 32

    SHADOW LINE

    EDGE TRIMPart no.

    1459

    W x L x H12 + 19 x 3050 x 10 + 24

    Alternative suspension S24 see Markant 600.

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are painted

    in CMC 001 Global white

    (equivalent to NCS 0902

    G48Y).

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at

    this stage.

    W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and

    then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.

    C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into

    position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.

    C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and

    if necessary the hangers adjusted.

    T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the

    tiles and a saw or knife used tocut the tiles to size.

    M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending of system module.

    The main runners haveinterlocking tongues in both ends,and can be locked together.

    Danoline Tiles 600

    A A

  • 5/25/2018 KATALOG DANOLINE

    40/13240

    A demand for a higher sound reduction (STC) can be

    required if the drywalls or partitions are not extended to

    the soffit of the deck, but to the suspended ceiling on ly.

    The construction therefore provides gr eat freedom of choice

    with regard to creating or moving walls.

    S y s t e m s

    Danopor is available for ceiling products with

    edge D, C, E, and A.

    S i z e s

    600 x 600 x 25 mm

    600 x 600 x 50 mm

    Other sizes on request.

    D r a f t s p e c i f i c a t i o n

    Danoline Danopor is installed on the back of

    Plaza 600, M1, 600 x 600 x 9.5 mm white

    painted as standard in 15/24 mm exposed

    suspension system.

    Product:

    Edge:

    Suspension:

    Contur 600

    D

    S2 4

    Linear 600

    C

    S2 4

    Belgravia 600

    E

    S15/S24/Ultraline

    Markant 600

    E

    S15/S24

    Plaza 600

    A

    S15/S24

  • 5/25/2018 KATALOG DANOLINE

    41/13241

    The natural properties of gypsum ensure that the Danoline

    products have a good sound reduction in low frequencies.

    In combination with Danapor a low density insulation pad

    placed inside sealed PE-faced bags and positioned on the

    back of the Danoline products a good result with sound

    reduction of both low, medium and high frequencies from

    room to room can be achieved.

    Sound-reducing characteristics can be varied further by

    selecting different thicknesses of Danopor. In addition to its

    sound-reducing properties, the construction also has good

    sound-absorbent properties throughout the frequency range.

    In particular the bass frequency sound absorption is good.

    I n c r e a s e d s o u n d r e d u c t i o n a n d a b s o r p t i o n r e a c h e d w i t h D a n a p o r w i t h o u t a f f e c t i n g

    d e s i g n a n d e x p r e s s i o n

    1267:

    Architect: Berg Arkitekter

    Project: Frsvarshgskolan, Stockholm - Sweden

    Product: Markant 600 - M1

    Danopor

    1267

  • 5/25/2018 KATALOG DANOLINE

    42/13242

    1179

  • 5/25/2018 KATALOG DANOLINE

    43/13243

    Corridor gives the appearance of fine lin e markings in a

    rectangular plank pattern. The ceiling is pri marily used in

    corridors and is self-supporting for up to 2.4 m between

    walls.

    Corridor is often used in small utility and ancill ary rooms

    for reasons of design and/or economy. Demounting reveals

    a completely free area without transverse suspension

    sections, optimal for work on technical installations.

    The ceiling panels can either be delivered to the building

    site and adjusted in situ or supplied in fixed dimensions.

    Fixed dimensions reduce wastage as well as building waste,

    making assembly faster and thus ch eaper.

    1195:

    Architect: Suunnittelukeskus Oy, Helsinki

    Project: Health care centre Kerava, Helsinki - Finland

    Product: Corridor 300

    1176, 1177, 1179:

    Architect: White Arkitekter

    Project: Halmstads Fastighetsbolag - Sweden

    Product: Corridor 300 - M1

    N e w a r c h i t e c t u r a l p o s s i b i l i t i e s c r e a t e d b y t h e u n i q u e y e t s i m p l e d e s i g n o f C o r r i d o r

    Corridor 300

    1195

    11761177

  • 5/25/2018 KATALOG DANOLINE

    44/132

    Max.24

    00

    44

    Measurements are in mm.

    Drawing no.: 35

    D e t a i l

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    300 x 1200 x 9.5 mm

    300 x 1500 x 9.5 mm

    300 x 1800 x 9.5 mm

    300 x 2100 x 9.5 mm

    300 x 2400 x 9.5 mm

    Can be manufactured to special length, max. 2400 mm.

    D r a f t s p e c i f i c a t i o n

    Danoline Corridor 300, M1, 300 x 1200 x 9.5

    mm, 300 x 2400 x 9.5 mm. White painted as

    standard.

    Installed on reinforced shadowline trim 1469.

    S u s p e n s i o n s y s t e m

    The flexprofile is an integrated part of the Corridor ceiling

    plank. Main Tee runner is used between se ctions and lines

    of Corridor planks, when the distance between the walls is

    greater than 2400 mm.

    Corridor 300. Joining of 2 short-edges using main runner65020.Drawing no.: 35.2.003

    Corridor 300 with shadow line edge tr im 1469.

    Drawing no.: 35.2.005

    Corridor 300 with wall tr im.Drawing no.: 35.2.004

  • 5/25/2018 KATALOG DANOLINE

    45/13245

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,

    see section Moisture . It is equally important to take account of other work such as technical installations before installation

    of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right-angles, t his makes

    installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be

    easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    C o m p o n e n t s

    FLEX RUNNER

    Delivered in loose

    parts with the

    elements

    W x L x H

    65 x 1194 x 44

    65 x 1494 x 44

    65 x 1794 x 44

    65 x 2094 x 44

    65 x 2394 x 44

    ADJUSTABLE HANGERS

    Part no. Lenght

    11022 120-200

    11030-99 200-270

    11030 250-320

    11040 250-440

    11070 380-690

    11090 500-940

    11120 750-1210

    11150 750-1440

    11200 1000-1940

    MAIN RUNNER

    Part no.

    65020

    W x L x H

    35 x 3600 x 38

    SHADOWLINE TRIM

    Part no.

    1469

    W x L x H

    20 + 20 x 3050 x 20 + 20

    WALL ANGLEPart no.

    1430

    W x L x H

    20 x 3050 x 40

    I n s t a l l a t i o n

    C o m p o n e n t s

    Suspension grid, hangers

    etc. are made from

    galvanised steel. The

    exposed sections are

    painted in CMC 001 Global

    white (equivalent to NCS

    0902 G48Y).

    S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.

    L a y o u t The ceiling is normally dividedin the centre, in this way theadjustments are the same size.Please note that the placing offixtures and ventilation units canaffect the correct layout

    S u s p e n s i o n h a n g e r s Where there is a change ofdirection in the corridor, asuspended main runner must beused to support the planks. Themaximum distance between thesuspension hangers is 750 mm,and a maximum 300 mm fromthe walls.

    W a l l T r i m The perimeter tr im is fixed tothe wall at max. 300 mm. Atcorners the tr im should be mitredaccurately.

    M a i n R u n n e r 6 5 0 2 0Main Runner 65020 can be usedto support Corridor planks atmaximum 2400 centres.It is necessary to secure themain runner at the perimeter,

    and to fix the Flex profile tothe main runner at every sixthplank. Where the short edges ofthe Corridor plank abut the mainrunner, the Flex profiles on eitherside of the Tee are secured toeach other.

    P l a n k s Where possible, Corridor planksshould be installed after all majorwork in the ceiling void has beencompleted. The flex-profile mustnot be over 6 mm shorter than

    the planks. The level of the tilesshould be checked when theinstallation is completed. Glovesshould be worn at all times whenhandling the tiles and a saw orknife used to cut the tiles to size.

    A d j u s t i n g t h e F l e xp r o f i l eIf the flex profile is brokenbecause of fittings, installationsor other implementations, theFlex profile has to be suspended.

    L e v e l l i n g t h eS u s p e n s i o n S y s t e m If suspension hangers have beenused, they must be adjusted toobtain an accurate level. Wherethere is a change in direction of

    planks, the main runner must besecured to the wall construction.

    Corridor 300

  • 5/25/2018 KATALOG DANOLINE

    46/13246

    0563

  • 5/25/2018 KATALOG DANOLINE

    47/13247

    The panels consist of long-format panels with an effective

    span of up to 2.8 m. Corridor F30 has the appearance

    of fine stroke markings in a rectangular plank pattern.

    The product has been styled to cope with the tough

    fire requirements set out in DIN 4102 (see section on

    properties).

    The unique quality about Corridor F30 is that it is the

    only ceiling without mineral wool to comply with this fire

    requirement.

    As a result of its fire properties, the ceiling provides great

    safety and is an obvious choice for use in e scape routes.

    0563, 0564, 0560:

    Architect: Hupach und Partner

    Project: DESY, Hamburg - Germany

    Product: Corridor F30

    E x c e l l e n t f i r e p r o p e r t i e s y e t d i s c r e e t j o i n t s b e t w e e n t h e e l e m e n t s c r e a t e d w i t h C o r r i d o r F 3 0

    Corridor F30

    0560

    0564

  • 5/25/2018 KATALOG DANOLINE

    48/13249

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless oth erwise stated, see section Moisture . It is

    equally important to take account of other work such as technical installations before installation of the ceiling is carried out. It is important for the end result

    that the ceiling tiles are installed at righ t-angles, this makes installation quicker and easier. It will facil itate inspections to installations above the ceiling as

    removal of the tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    C o m p o n e n t s

    WALL ANGLE

    Part no.

    F3000012

    W x L x H

    40 x 3000 x 60

    I n s t a l l a t i o n

    C o m p o n e n t s

    The wall profiles are made

    from aluzinc. Painted to

    RAL 9016

    S e t t i n g o u t The position of the wall anglesshould be marked on the wallsand columns. The bottom flangeof the wall angles is the levelof Corridor planks. Fixation withscrews at max 400 mm c/c.

    A d j u s t m e n tThe Corridor panels are crosscut with a jigsaw for metal.Longitudinally cuts are made witha normal saw.

    F i r e c a p Into the back of the panel asquare furring cap is inserted.This must close the openings intothe Corridor panel.

    A i r i n l e t s a n do u t l e t s Cutting out for opening is doneby a jigsaw, from the front side.Final adjustment by a fine toothsaw or a Stanley knife.

    L i g t h f i x t u r e s Installation of 300 mmlightfixture. This installationrequires a special Corridor panelwith an extra layer of gypsumboard. The cut end adjacent tothe luminarie shall be fil led outby GKF gypsum board. On the

    back of the light fixture a GKFgypsum board shall be fixed, andthe 3 elements are now installedbetween 2 standard panels. Thelight fixture also has to be screwfixed to the 2 adjacent panels.

    W a l l t r i m The wall angles shall be furredby Fireboard srips of 120 mm.At elements which are cutlongitudinal an extra strip ofFireboard shall be fixed. Fixationby drywall screw.

    L a y - i nThe Corridor panels are laid indirectly on the wall angles. Thepanels are self-supporting to2800 mm free span.

    E n d - e l e m e n t s Measurement A for the secondlast panels is set, and themeasurement B is made for thelast panel. The end panel isthen cut to size and is laid inon the wall angle with the extraFireboard str ip.

    C l o s i n g The second last panel can nowbe laid in between the end paneland the third last panel.Cotten gloves should be wornat all time when handling theCorridor panels.

    L i g t h f i x t u r e s Installation of light fixture lessthan 300 mm. Cut out for thesize of the light fixture. All openend in the panels to be closedby GKF gypsum board, whichshall be screw fixed to the metalprofile in the panel. If necessary,

    additional metal profile is addedto secure the gypsum fil l -out.Fill -out gypsum strips to be screwfixed. The light fixture shall bescrew fixed to the panel. On theback of the panel an additionallayer of GKF board shall be fixed.

    F i r e c a p f i x i n g The fire protection cap shall befixed with angle brackets, andthe void between the cap andthe air inlet/outlet shall be fil ledwith gypsum mortar.

    A B

    Corridor F30

  • 5/25/2018 KATALOG DANOLINE

    49/13250

    1266

  • 5/25/2018 KATALOG DANOLINE

    50/132

    Max.28

    00Max

    .2800

    48

    Measurements are in mm.

    D e t a i l

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    P r o d u c t

    S i z e s

    300 x (length) x 12.5 x mm

    Max. Length 2800 mm.

    D r a f t s p e c i f i c a t i o n

    Danoline Corridor F30, White laminated as

    standard, Installed on wall angle F3000012.

    Drawing no.: 36

    S u s p e n s i o n s y s t e m

    Corridor F30 is a selfsupporting cei ling system with

    integrated steel profiles, making a free span of max. 2800

    mm

    Corridor F30, adjustment panel at wall angle, and withgypsum shadow edge trim.Drawing no.: 36.2.004

    Corridor F30, jointing of long-edge against short edge.

    Drawing no.: 36.2.003

    Corridor F30 fixed with wall angle at gypsum boards onsteel structure.Drawing no.: 36.2.001

    Corridor F30 panels with wall angle and gypsum boardshadow trim.Drawing no.: 36.2.002

  • 5/25/2018 KATALOG DANOLINE

    51/13251

    Corridor swing is a hinged cei ling construction whereby

    apertures on all four lateral edges achie ve a rough yet

    floating, light design.

    The panels are rectangular in appearance, with l engths

    of up to 1.8 m. Corridor Swing is fitted with a hinge and

    swivels down without the use of tools.

    The panel remains suspended during inspection work,

    allowing simple and fast access to installations.

    D i s t i n c t i v e p e r f o r a t i o n s f a v o u r t h e f u n c t i o n a l d e s i g n o f C o r r i d o r S w i n g 6 0 0

    1266:

    Architect: Arkitektgruppen Aarhus

    Project: Greve Rdhus - Denmark

    Product: Corridor Swing - M1

    1156, 1158:

    Architect: White Arkitekter Gteborg

    Project: Medicinskt Kunskapshus, Gteborg - Sweden

    Product: Corridor Swing - M1

    Corridor Swing 600

    1158

    1156

    1158

  • 5/25/2018 KATALOG DANOLINE

    52/132

    1200,15

    00,1800

    600

    1200,15

    00,1800

    600

    52

    Measurements are in mm.

    D e t a i l

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 1200 x 12.5 mm

    600 x 1500 x 12.5 mm

    600 x 1800 x 12.5 mm

    D r a f t s p e c i f i c a t i o n

    Danoline Corridor Swing 600, G1,

    600 x 1200 x 12.5 mm, installed in suspension

    system 721000.

    Drawing no.: 52

    S u s p e n s i o n s y s t e m

    The Swing profiles on the walls and the suspended friezes

    to be installed as per module of Corridor 600

    Corridor Swing 600, joint of 2 short-edges with profileW-Swing 3.Drawing no.: 52.2.003

    Corridor Swing 600 with fix fr ieze of painted Mitex panel.

    Drawing no.: 52.2.001

    Corridor Swing 600, longitudinal joint between 2 panels.

    Drawing no.: 52.2.002

  • 5/25/2018 KATALOG DANOLINE

    53/13253

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless oth erwise stated, see section Moisture . It is

    equally important to take account of other work such as technical installations before installation of the ceiling is carried out. It is important for the end result

    that the ceiling tiles are installed at righ t-angles, this makes installation quicker and easier. It will facil itate inspections to installations above the ceiling as

    removal of the tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.

    PROFILE W-SWING 1 / WHITE PAINTED

    Part no.

    729196

    W x L x H

    8/12 x 2400 x 55

    PROFILE W-SWING 5 / WHITE PAINTED

    Part no.

    729200

    W x L x H

    68 x 2400 x 53

    PROFILE W-SWING 2 / WHITE PAINTED

    Part no.

    730162

    W x L x H

    40 x 2400 x 16

    METAL CLIP / GALVANIZED

    Part no.

    721175

    W x L x H

    70 x 58 x 80

    PROFILE W-SWING 3 / WHITE PAINTED

    Part no.

    729198

    W x L x H

    92 x 2400 x 16

    SCREW/NUT W34 / GALVANIZED

    Part no.

    718473

    PROFILE W-SWING 4A / WHITE PAINTED

    Part no.

    731618

    (Combined with W-swing 2)

    W x L x H

    85 x 2400 x 66

    SWING HANGER / UNPAINTED

    Part no.

    SW6MB

    Incl. element

    4 x 582 x 53

    I n s t a l l a t i o n

    C o m p o n e n t s

    C o m p o n e n t s

    Profiles and accessories

    are made from galvanised

    steel. The painted sections

    are painted in RAL 9010

    (equivalent to NCS 0502

    Y14R).

    P l a n n i n g t h ec e i l i n g s u r f a c e The module measurement is24 mm larger than the actualelements. When installed therewill be 24 mm gab around alledges of the element.

    P r o f i l e d i s t a n c e s The W swing 2 profiles are installedunder the metal clips with the W34clip. Now the distance betweenthe suspension points on the Wswing 2 profiles must be adjusted,so the distance between them isthe length of the element minus 50mm. The two swing profiles must beinstalled, so the suspension pointsare directly opposite each other due

    to the following installation of theactual elements.

    F i x i n g o f t h e m e t a lc l i p The metal clip is fixed to the wallor vertical steel profiles at c/c800 mm. The lowest edge ofthe metal clip should be 65 mmhigher than the desired ceiling

    height. It is very important thatthe frame work is rigid so itcannot deform the elements wheninstalled.

    D i m e n s i o n a l o u t l i n e ,D i s m o u n t a b l e f r i e z e M indicate module line. There mustbe a 12 mm gap towards the Corridorswing element and a 18 mm gapto the frieze. Horizontal U-profilesand vertical C-profiles are installedin order to create a rigid fr ame forthe swing profiles. W-swing 2 and4A profiles are fixed at c/c 800 mmin the vertical steel profiles with the

    W34 bolt. The wall angle is fixed tothe wall at c/c 400 mm.

    F i n i s h i n g t h ei n s t a l l a t i o n The element is swung up tohorizontal level and the hangersare held in vertical position soit can be slid into the W-swing2 profile.

    I n s t a l l a t i o n o f t h ee l e m e n t s The ceiling elements are hungalong one of the sides to beginwith. The element is kept verticalwith the hanger pointing up andthe hanger is clasped on the

    W-swing 2 profile.

    I n s t a l l a t i o n o fs w i n g h a n g e rS W 6 M B The swing hanger is fixed tothe fastened SW15 profile,the other SW15 swing profileis pushed into its slot, so the

    hanger is fixed in the hole ofthe SW15 profile. Now the otherSW15 profile can be fixed usingprevious described method. Itis not recommend installing thehanger by tensioning as it willgive an inappropriate sidewaysforce on the SW15 profiles.

    D i m e n s i o n a l o u t - l i n e , w a l l j u n c t i o n M indicates the module line.There must be a 12 mm gap oneach side of M. The metal clip,721175 is fixed to the wall at800 c/c mm and the W-swing 2profile is fixed to the metal clipwith the W34 bolt.

    D i m e n s i o n a l o u t - l i n e , F i x e d f r i e z e M indicates the module line.There must be a 12 mm gap oneach side of M. The metal clip,721175 is fixed to the verticalprofiles and horizontal U-profilesare installed so the fixed friezecan be screwed onto them. TheW-swing 2 profile is fixed to themetal clip with the W34 bolt.

    A s s e m b l y o f t h ee l e m e n t s The elements come withdepressed fittings. The SW15profiles are fixed with thesupplied screws through thedepressed fitting into the

    element. The distance betweenthe end of the profile to the edgeof the element must be 15 mm.Only one SW15 swing profile isfixed at this stage. The base forfixing the load bearing profilesmust be plane and solid. Theremust be no deflection of theprofile during the fixing of it.

    Corridor Swing 600

    M MM

    50 mm

    I n s t a l l a t i o n o fS w i n g c r o s s p r o f i l eThe cross profile is placed ontothe metal clip so that the hole inthe cross profile is directly abovethe centre hole in the metalclip. The foil cover is removed

    from the adhesive pads and thecross profile is pressed tightlyagainst the element. The screwis fixed through the hole in theprofile and the centre hole in themetal clip.

  • 5/25/2018 KATALOG DANOLINE

    54/13254

    1072

  • 5/25/2018 KATALOG DANOLINE

    55/13255

    Danopanel, like Contur, features a monolithic, linedivided

    surface.

    The panelling is supplied ready painted and fitted without

    visible screws. Since there is no handling by painters,

    installation time is short, achieving a good overall

    economy.

    Direct screwing onto the metal furring system/timber

    battens ensures a low construction height.

    P r o p e r t i e s a n d m a t e r i a l s u n i t e d i n h a r m o n y t o c r e a t e t h e s i m p l e a n d p u r e l i n i n g c e i l i n g D a n o p a n e l

    1072:

    Architect: Asger Bergo Friis

    Project: Ruds Vedby Skole SFO - Denmark

    Product: Danopanel - Q1

    1276:

    Architect: Arkitekt Erik Eriksen

    Project: Daginstition, Maglekrvej, Grlse - Denmark

    Product: Danopanel - G1, R

    Danopanel

    1276

  • 5/25/2018 KATALOG DANOLINE

    56/132

    600

    600

    300

    300

    56

    Measurements are in mm.

    Drawing no.: 61

    D e t a i l

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    Other perforation patterns are manufactured to

    order. Please see section Perforations.

    P r o d u c t

    S i z e s

    600 x 600 x 12.5 mm

    D r a f t s p e c i f i c a t i o n

    Danoline Danopanel, G1, 600 x 600 x 12.5 mm.

    White painted as standard Installed on metal or

    wooden furring system.

    Danopanel, fr ieze connection.

    Drawing no.: 61.2.001

    F u r r i n g s y s t e m

    The Danopanel must be screw fixed to furring of

    25 x 100 mm wood battens at 300 mm c/c.

  • 5/25/2018 KATALOG DANOLINE

    57/13257

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise

    stated, see section Moisture . It is equally important to take account of other work such as technical installations before

    installation of the ceiling is carried out. It is important for the end result that the ceili ng tiles are installed at right-

    angles, this also makes installation quicker & easier. It is not recommended that ceilings are installed at a temperature

    consistantly over 50C.

    I n s t a l l a t i o n I n s t a l l a t i o n

    Danopanel is screwed to the furring system using a plain-

    end screw, wood furring no. TA35, steel furring MSB15SB.

    It should be noted that the panels must be turned around

    from row to row and this influences the position of the

    middle furring piece.

    L a y o u t Generally start setting out fromthe centre of the room. TheDanopanels are installed on afurring of either wood or steel.The furring is spaced at 300mm c/c.

    F r i e z eThe last row of tiles can also bescrew fixed directly through theDanopanel. The position of thescrews shall be max. 30 mm fromthe clips behind the panel.

    A d j u s t m e n t s Cuttings and adjustments of thepanels can be carried out by afine tooth saw or a Stanley knife.If the last row is a full size panel,the clips should be cut . If thepanels have to be cut to a smallerwidth the clips shall be removedand re-fixed onto the cut panel.

    I n s t a l l a t i o n Begin the installation of first rowfrom the centre of the room usinga chalk line. The Danopanels arescrew fixed through the holes inthe factory mounted clips. Onthe next rows of panels the clipscan slide in behind the adjacentpanels thus only screw fixing the

    clips on the other side etc.

    Danopanel

  • 5/25/2018 KATALOG DANOLINE

    58/13258

    1079

  • 5/25/2018 KATALOG DANOLINE

    59/13259

    Combipanel is a lining product that features fine markings

    in rectangular plank patterns.

    Combipanel comes with the s urfaces ready painted and

    can be fitted in free bond as a result of an integral furring

    system.

    Combipanel only requires metal furring every 1000 mm and

    can be fitted straight onto rafter constructions.

    L o n g a n d s l i m d i m e n s i o n s m a k e C o m b i p a n e l u n i q u e

    1079:

    Architect: Claus B. Hansen

    Project: Brndby Stadion - Denmark

    Product: Combipanel - G1

    0133:

    Architect: Jrn Langvad A/S

    Project: Q8 hovedkontor - Denmark

    Product: Combipanel - G1

    Combipanel

    0133

  • 5/25/2018 KATALOG DANOLINE

    60/132

    Max.1000

    60

    Combipanel, wall connection.

    Drawing no.: 65.2.001

    S u b s t r u c t u r e

    Combipanel shall be fixed to a levelled substructure, which

    can be directly to rafters or ceil ing joists without furring. If

    furring is being used, it can be 25 x 100 mm wood battens

    at 300 mm c/c.

    Combipanel only needs to be screw fixed at each 1000mm.

    Measurements are in mm.

    Drawing no.: 65

    D e t a i l

    P e r f o r a t i o n

    Globe: G1

    Quadril: Q1

    Micro: M1

    Regula: R

    P r o d u c t

    S i z e s

    300 x 1200 x 9.5 mm

    300 x 1800 x 9.5 mm

    300 x 2400 x 9.5 mm

    D r a f t s p e c i f i c a t i o n

    Danoline Combipanel, G1, 300 x 2400 x 9.5 mm

    on metal or wooden furring system.

  • 5/25/2018 KATALOG DANOLINE

    61/13261

    S t o r a g e & I n s t a l l a t i o n

    Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise

    stated, see section Moisture . It is equally important to take account of other work such as technical installations before

    installation of the ceiling is carried out. It is important for the end result that the ceili ng tiles are installed at right-

    angles, this also makes installation quicker and easier. It i s not recommended that ceilings are installed at a temperature

    consistantly over 50C.

    I n s t a l l a t i o n

    L a y o u t Generally start setting outfrom the centre of the room.The Combipanels are installeddirectly on a levelled substructure

    max. 1000 mm c/c.

    I n s t a l l a t i o n Begin the first row ofCombipanels in a corner of theroom with the groove of thepanels facing the room. Along

    the wall screw fixing shall bethrough the panel. Along the walla 22 mm distance furring shallbe added. The enclosed metalS-profile shall be placed into thegroove, and screw fixing takeplace through the holes in theprofile only.

    T h e S - p r o f i l e The enclosed s-shaped metalprofile shall be placed staggeredto the end joints of the panels.Screw fixing at max 1000

    mm c/c.

    E n d r o w For the last row of Combipanelsa 22 furring along the wall shallbe fixed. The last row of panelsare screw fixed direct through the

    panels into the furring.

    Combipanel

  • 5/25/2018 KATALOG DANOLINE

    62/13262

    1246

  • 5/25/2018 KATALOG DANOLINE

    63/13263

    The Designpanel products offer scope for a c eiling design

    with large, continuous surfaces. Combined with acoustic

    control, perforations are used, taking the shape of patterns

    embossed almost plastically into the surface.

    Designpanel are fitted with tapered edges along the long

    edges, on request it can be made with tapered edges on all

    four edges, giving an even and smooth intermediate joint

    filling between panels and reducing cracking.

    O p t i m u m m e t h o d f o r l a r g e c e i l i n g s m e a n s u s i n g D e s i g n p a n e l w i t h f o u r t a p e r e d e d g e s

    1246:

    Architect: Link Arkitekter, Oslo

    Project: Nannestad skole - Norway

    Product: Designpanael 1200 - Q2F

    1153, 1154, 1155:

    Architect: Semren Arkitektkontor Gteborg

    Project: Bors Hjskole - Sweden

    Product: Designpanael 900 - M1F

    Designpanel 900 and 1200

    1154

    11551153

  • 5/25/2018 KATALOG DANOLINE

    64/132

    300

    900

    3001000

    64

    Designpanel on wood or steel furring

    respectively. Note that the short edge is

    available with tapered edge.

    F u r r i n g , s u s p e n d e d o n s t e e l

    The ceiling is fitted onto a plane steel furring of the

    CD-type. The system consists of primary and secondary

    framework. The system is constructed with a central

    distance of 300 mm perpendicularly lengthwise to the

    Designpanel. All short edge joints must be supported.

    As an alternative framework type MF5 and primary MF7

    can be used.

    P e r f o r a t i o n

    Globe: (900) G1F, G2F ; (1200) G2F, G4F

    Quadril: (900) Q1F, Q2F ; (1200) Q2F, Q4F

    Micro: (900) M1F, M2F ; (1200) M2F

    Regula: R

    Other perforation patterns are manufactured to order.

    Please see section Perforations.

    P r o d u c t

    S i z e s

    900 x 2700 x 12.5 mm

    1200 x 2400 x 12.5 mm

    D r a f t s p e c i f i c a t i o n

    Danoline Designpanel 900/1200, G1F,

    900 x 2700 x 12.5 mm

    1200 x 2400 x 12.5 mm

    installed in metal or wooden furring system.

    F u r r i n g , B D - 3 0 ( E I 3 0 ) c o n s t r u c t i o n

    The ceiling is fitted onto a plane wooden furring 25 x 100

    mm. The furring is fitted perpendicularly lengthwise to the

    Designpanel. The maximum distance for the furring is 300

    mm. All short edge joints must be supported.

    D e t a i l

    Designpanel on traditional furring,wall junction and boardconnection.Drawing no.: 62.2.001

    Measurements are in mm.

    Drawing no.: 62

    Measurements are in mm.

    Drawing no.: 62

    Designpanel on CD steel furr ing system, wall junction andboard connection.Drawing no.: 62.2.002

  • 5/25/2018 KATALOG DANOLINE

    65/13265

    Designpanel 900 and 1200

    B D - 3 0 ( E I 3 0 ) c o n s t r u c t i o n

    Damp proof barrier is placed over the furring. If the damp proof

    membrane is placed immediately over the perforations, but under

    the furring, the ability to absorb the sound is severely reduced.

    The present absorption data depends on a 150 my () plastic

    foil. A foil with any other thickness will affect the acoustic

    capacities. In order to achieve a BD-30 construction, 250 mm

    rock wool insulation must be a part of the construction.

    F u r r i n g , w o o d

    The ceiling is fitted to a plane wooden furring 25 x 100 mm.

    The furring is fitted to the rafters or beams with a maximum

    central distance of 1000 mm. The furring is

    fitted perpendicular lengthwise to the ceiling

    panel. The maximum c/c distance of the

    furring is 300 mm. The short edges

    of the panel joints must be

    supported.

    F u r r i n g , s t e e l

    The ceiling is fitted to a plane s teel furring of the CD-2

    type. The system consists of primary runners at max 900

    mm c/c, and secondary runners at 300 mm c/c. Along

    all walls and edges the wall profiles UD 28 x 27 are fixed

    and secured to the furring at max 400 mm. The top partof the hangers, of the nonius model, are sec ured to the

    above construction at 900 and attached

    to the primary CD-60 runners

    with the lower part of the

    hanger. The cross connector i s

    placed per 300 mm and the

    underlying secondary profiles

    are secured into them. The short e dges of the panel must

    be supported along its entire lenght by fixing the panel to

    the furring system.

    G r o u p i n g

    The starting point for the fitting of the desi gn panels is

    where a level line can be achieved through the whole

    fitting area. The first row is fitted along a s tring in order

    for the perforated sections to be in line. The fitting is

    started in the middle of the room, as far as possible, and

    the Designpanels are fitted from the middle towards each

    side in order for the frie zes to

    be equally wide. The panels

    are delivered undersized and

    must be fitted with a distance

    of up to 4 mm.

    The perforated sections must be in line with their own line

    and be perpendicular to the sections next to them.

    F i t t i n g

    The Designpanel is screwed onto either wood or steel at

    every 200 mm along the short edges of the panel and in

    section sizes of 300 x 600 mm on the rest of the panels,

    see drawing 62.

    E x p a n s i o n j o i n t s

    Panel area more than 70 m, or in cases where one of the