creating expressive ceilings www.danoline.com Expressive gypsum ceilings
5/25/2018 KATALOG DANOLINE
1/132
creating expressive cei l ings
w w w . d a n o l i n e . c o m
Expressivegypsumceilings
5/25/2018 KATALOG DANOLINE
2/132
C o n t e n t s
PrefaceDanoline, history, possibilities Page 3
ProductsSUSPENDED CEILINGS
Contur 600 Page 12
Linear 600 Page 16
Markant 500 and 600 Page 20
Belgravia 600 Page 26
Plaza 600 Page 30
Danoline tiles 600, White and Metallic Page 34
Danoline tiles 600, Medley Page 36
ACCESSORIES
Danopor Page 40
SELF-SUPPORTING CEILINGS
Corridor 300 Page 42
Corridor F30 Page 46
Corridor Swing 600 Page 50
LININGS
Danopanel Page 54
Combipanel Page 58
Designpanel 900 and 1200 Page 62
Tectopanel Page 66
Contrapanel Page 70
Kinopanel Page 74
DESIGNELEMENTS
Curvex Page 78
Mitex Page 80
Solopanel and Stratopanel Page 82
Properties
SURFACING
Gypsum as a natural palette Page 88
ACOUSTICS
Gypsum regulates sound Page 90
FIRE
Gypsum as natures sprinkler Page 98
INDOOR CLIMATE AND ENVIRONMENT
Gypsum can breathe Page 100
LOAD-BEARING CAPACITY AND WEIGHT
Gypsum as a weightlifter Page 102
MOISTURE
Gypsum as a natural skin Page 104
LUMINOUS REFLECTANCE
Gypsum mirrors the light Page 106
PerforationsPerforations and patterns Page 111
Globe, G Page 112Quadril, Q Page 113
Micro, M Page 114
Designpanel Page 115
Cleaning and maintenanceSuspended and Self-supporting ceilings Page 118
Ceiling linings, acoustic and plain Page 119
SummarySuspended ceilings Page 122
Linings Page 124
Self-supporting ceilings Page 126
Designelements Page 127
Accessories Page 128
H o w t o u s e t h e i n d e x
All information in the index is ge neral directions about the Danoline products. There may be project-specific details which
have not been accounted for. It is a foregone conclusion that users of Danoline data have technical building skills and that
t hey have t he u sual p ro je c t r e sponsi bi li ty . In fo rmat ion on our web si te w w w . d a n o l i n e . c o m i s always up to dat e
and applicable. Our technical service department is always at your disposal with further information and guidance.
5/25/2018 KATALOG DANOLINE
3/132
The difference between the ordinary and the unique may
lie in the tiny details. The obser vers feeling of harmony
in a building, the surprise when his eye spots a solution
that is slightly more beautiful than expected at first sight.
Architecture is impressive when functionality blends with
aesthetics and form a perfect whole.
All the elements of a building must form integral parts
of the whole, allowing the expression of the architects
language of form and original intention. The ceili ng must
be characterised as a not quite inessential feature of the
whole building. When dealing with plaster board ceilings
Danolines multiple resources are at your disposal any
time. We are pleased to offer you a developing partnershipany time to help you achieve your specifications and meet
your wishes in terms of architectonic solutions. If you
think Danoline as early as in the ini tial concept, you will
benefit most from our experience and technical know-how.
We are competent sparring partners who create i ndividual
products. Helping you turn your creative conceptions into
implementible solutions would be a pleasure to us.
Plaster is a flexible material which can easi ly be moulded.
In the Danoline ceilings we take advantage of the
mouldable properties of the material by punching holes
and patterns which add a different dimension of aesthetics
to the plaster. At the same time this material offers a
number of good properties which in their manner add to
the building.
Y o u r w a y s o f c r e a t i n g e x p r e s s i v e c e i l i n g s m a d e o f p l a s t e r b o a r d p a n e l s s t a r t h e r e
Plaster gives good opportunities for creating speci al/unique
solutions that meet your specifications and wishes as to
ceiling expression. At Danoline we stress continuous product
development to ensure that we meet the continuous
requirements of beautiful and persuasive solutions.
Plasterboards for the manufacture of Danoline ceilings
have been developed by Knauf Danogips, the leading
Scandinavian producer of plasterboards. Danoline s and
Knauf Danogips efforts within product development and
production have secured our position as partners to any
type of building project in Northern Europe.
3
5/25/2018 KATALOG DANOLINE
4/1324
5/25/2018 KATALOG DANOLINE
5/1325
1165
5/25/2018 KATALOG DANOLINE
6/132
1165:
Architect: Semren Arkitektkontor, Gteborg
Project: Ungdoms bolig, Gteborg - Sweden
Product: Designpanel 1200
F o r g o o d r e a s o n s p l a s t e r h a s b e e n t h e p r e f e r r e d m a t e r i a l f o r c e i l i n g s f o r c e n t u r i e s
Plaster forms a natural part of modern building design,
but as a material it dates back in history. For centuries
plaster has been used to meet both functional and aesthetic
requirements of buildings. Plaster has been used in as
different places as decorative ceilings in the beautiful
Italian and French Renaissance palaces as for the pyramids
in Pharaonic Egypt. Wherever it has been used, builders
have had the ability to exploit its characteristic properties
to create outstanding results.
The method used to process gypsum is quite simple, and
this is the most essential reason why it was known as a
building material way back. The use of plaster found favour
in earnest in the antique Roman culture around the year
0 A.D. At that time many buildings were made in marble
and then covered with a thin coat of plaster and painted
in bright colours. At the same time the great flexibil ity
and mouldability of the plaster meant that this material
was widely used for stuccowork inside buildings. Plaster is
suitable for detailing, and it was therefore used for the fine
and artistic ornamentation and embellishments on walls and
ceilings, which may be seen in Italian Baroque and Rococo
architecture. This material allowed for the cre ation of
reliefs and ornamentation which had an outstanding impact
on the rooms, whereas their weight was unsubstantial.
In year 1775 French Lavoisier found the chemical formulafor gypsum which paved the way for industrial processing
of the material. Plaster is made from the gypsum stone
mineral which is found naturally in Germany, France and
Italy. Gypsum stone is converted into burnt gypsum via
heating, crushing and mixing with water. The material then
solidifies in the shape which it is in.
6
5/25/2018 KATALOG DANOLINE
7/1327
5/25/2018 KATALOG DANOLINE
8/132
1290
1276 1157
8
5/25/2018 KATALOG DANOLINE
9/132
1276:
Architect: Erik Eriksen, Grlse
Project: Daginstition, Maglekrvej, Grlse - Denmark
Product: Danopanel - G1, R
1157:
Architect: MA Arkitekter, Bors
Project: Hgskolan i Bors- Sweden
Product: Corridor Swing 600 - Q1
1290:
Architect: S og I arkitekter
Project: OBH Gruppen, Odense - Denmark
Product: Contur 600 - M1 , Designpanel 900 - M1F
1287:
Architect: Hune & Elkjr
Project: Korsvang, Assens - Denmark
Product: Tectopanel - G1
1284:
Architect: Rudolf Lolk A/S
Project: Arkitektfirmaet Rudolf Lolk A/S, Esbjerg - Denmark
Product: Designpanel 1200 - M1F
1137:
Architect: Wingrd Arkitekt kontor
Project: Astra Zeneca tnghuset, Gteborg - Sweden
Product: Mitex - R
N o w o u r e x t e n s i v e a s s o r t m e n t o f p l a s t e r b o a r d p a n e l s a f f o r d s
e n d l e s s d e s i g n o p t i o n s
Smooth surfaces and clean lines are characteri stics
of contemporary beautiful, minimalist buildings and
the simplistic expression of the plaster contri butes to
architectonic clarity. It is possible to cr eate elements which
recede into the background and do not distract attention
from the architectonic expression of the r oom. With plaster
the strict and minimalist expression is preserved and the
extensive mouldability of the material also affords wide
opportunities for creating individual solutions with a high
degree of detailing.
The great flexibility of the material, means that
functionality and aesthetics can form a synthesis so the
finish of the room becomes just as intended. With Danolineceilings there are infinite combinations of expressions,
as the surface of the plaster allows for the application
of many types of paint, foils or punchings, so it may be
adapted fully to the expression of the room.
Beside the evident aesthetic advantages of using plaster,
this material also offers a number of other properties which
contribute favourably to the building. Gypsum is a natural
material with a long life and it is environmentally friendly.
Plaster can emit and adsorb vapour which makes it play
an important part if the building is to have a good indoor
climate.
Plaster also affords good acoustic properties. The different
types of perforation offer varying properties in the form of
sound absorption and reflection, in this way ceiling panels
can tune the room and render fine acoustic conditions . The
reflection of light is also easily i nfluenced by the use of
plaster as the surface structure appears highly varied and
with different reflective properties, depending on the type
of paint applied.
1137
1284
1287
9
5/25/2018 KATALOG DANOLINE
10/132
5/25/2018 KATALOG DANOLINE
11/132
Products
1149
5/25/2018 KATALOG DANOLINE
12/13212
1324
5/25/2018 KATALOG DANOLINE
13/13213
Contur gives the appearance of a monolithic surface
finished with fine line markings. The perforations on Contur
appear more distinctly than on other types of ceilings
and aesthetically, therefore, will accentuate the acoustic
solution selected.
Choosing fixed dados, arches or folded plaster achieves
an elegant framework to the ceiling. Contur produces a
concealed grid appearence, and is similar to Danopanel and
Tectopanel.
E x p r e s s i o n a n d a c o u s t i c s e n h a n c e d b y t h e s u b t l e p e r f o r a t i o n o n C o n t u r
1149:
Architect: Liljewall Arkitekter, Gteborg
Project: Biotechhuset, Gteborg - Sweden
Product: Designpanel 900 - M2F
1324:
Architect: Dall & Lindhardtsen
Project: Nrum Gymnassium - Denmark
Product: Contur 600 - G1
1278:
Architect: Dall & LindhardtsenProject: Holbk Sygehus - Denmark
Product: Contur 600 - G1
1223:
Architect: Sisustusarkkitehdit Gullstn-Inkinen Oy
Project: Teknos Oy, Rajamki, paint factry - Finl and
Product: Contur 600 - G1
Contur 600
1223
12781324
5/25/2018 KATALOG DANOLINE
14/132
600
Max.600
600
Max.600
600 1200
14
S u s p e n s i o n s y s t e m
The spacer bars shall be fixed max. 100 mm from the
hangers. At joints of main T-runners, hangers shall be fixed.
The suspension hanger must be fixed to the main r unner
at 1500 mm centres and not less than 100 mm from the
wall angle.
Measurements are in mm.
Drawing no.: 10
D e t a i l
Cross section 4,Contur 600, with shadow edge tr im.Drawing no.: 10.2.006
Cross section 3,Contur 600, with shadow edge tr im.Drawing no.: 10.2.005
Longitudinal section,Contur 600, with shadow edge tr im.
Drawing no.: 10.2.004
Longitudinal section,Contur 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.003
Cross section 2,Contur 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.002
Cross section 1,Contur 600 with painted fix fr ieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 10.2.001
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 600 x 12.5 mm
625 x 625 x 12.5 mm
Other sizes on request.
D r a f t s p e c i f i c a t i o n
Danoline Contur 600, M1, 600 x 600 x 12.5 mm,
White painted as standard, for concealed 24 mm
suspension systems.
5/25/2018 KATALOG DANOLINE
15/13215
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
C o m p o n e n t s
MAIN RUNNER
Part no.
85030W x L x H
24 x 3600 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
SPACER BAR
Part no.
8260013
8269913
L
600
300
SHADOW LINE
EDGE TRIM
Part no.
1459
W x L x H
12 + 19 x 3050 x 10 + 24
WALL ANGLE
Part no.
1438
W x L x H
19 x 3050 x 32
I n s t a l l a t i o n
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they shouldbe screwed to the soffit. It isimportant that the suspensionis plumb. The main runners arefixed parallel at 300 mm or 600
mm centres.
C h e c k i n g t h es u s p e n s i o n s y s t e ma n d s p a c e r b a r When the suspension systemis installed, the levels and
angles should be checked andif necessary the hangers adjusted.The spacer bar should be installedat a maximum of 100 mm fromthe hangers and with a distanceof max. 1500 mm c/c.
W a l l T r i m The wall angle should be fixedat max. 300 mm centres. Atcorners the tr im should be mitredaccurately.
M a i n r u n n e r The suspension hanger must befixed to the main runner at 1500mm centres and not less than100 mm from the wall angle.
T i l e s The level of the tiles should bechecked when the installation iscompleted.Gloves should be worn at all
times when handling the tiles anda saw or knife used to cut thetiles to size.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
J o i n i n g t h e M a i nR u n n e r s The main runners haveinterlocking tongues at bothends enabling them to be joined
together, an additional hangermust be used at this point.
Contur 600
A A
5/25/2018 KATALOG DANOLINE
16/13216
1124
5/25/2018 KATALOG DANOLINE
17/13217
Linear is perceived as floating, self-contained panels,
defined by sharp, almost navigationally con tinuous
alignments. Diagonal to the alignments, the ceiling gives
the appearance of large interconnected surfaces. Th e ceiling
is wellsuited to renovating existing ceilings and on account
of its styling is very simple to mount and demount. Linear
almost covers the grid system. This has the advantage of
concealing old grid.
The option of having an installation height of just 63
mm ensures greater floor-to-ceiling hei ght, thus providing
improved space for engineering installations. In addition,
the ceiling can be painted while actually in the rail system.
The design and assembly clips prevent the board frombeing pushed up out of the rail system during cleaning and
painting.
G e o m e t r i c a l c h a r a c t e r i s t i c s e m p h a s i z e d b y t h e s h a r p e d g e s o f t h e i n d i v i d u a l L i n e a r b o a r d
1124:
Architect: KHR ArkitekterProject: Arlanda Pir F/5:an - Arlandaflygplats - Sweden
Product: Linear 600 - M1
0950:
Architect: CF Mller
Project: Vejle Sygehus - Denmark
Product: Linear 600 - G1
Linear 600
0950
09500950
5/25/2018 KATALOG DANOLINE
18/132
600
Max.600
600
Max.600
6001200
18
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 600 x 12.5 mm
D r a f t s p e c i f i c a t i o n ,
Danoline Linear 600, M1, 600 x 600 x 12.5 mm,
White painted as standard, for exposed 24 mm suspension
systems.
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 600 mm, and shall be made
from 1200 mm cross-Tee. The suspension hanger must be
fixed to the main runner at 1200 mm centres and not le ss
than 400 mm from the wall angle.
Danoline recommends the use of suspension systems with
straight connections between main runners and cro ss tees,
so any differences in levels are avoided, i.e. the suspension
systems components are all at the same level.
Measurements are in mm.
Drawing no.: 15
D e t a i l
Linear 600, with fr ieze of Plaza 600 Regula, plain.
Drawing no.: 15.2.004
Linear 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 15.2.005
Linear 600, with intermediate fr ieze of Plaza 600 Regula.
Drawing no.: 15.2.008
5/25/2018 KATALOG DANOLINE
19/13219
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
85030
W x L x H
24 x 3600 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
85130
85230
85430
W x L x H
24 x 300 x 38
24 x 600 x 38
24 x 1200 x 38
SHADOW LINE
EDGE TRIM
Part no.
1459
W x L x H
12 + 19 x 3050 x 10 + 24
WALL ANGLE
Part no.1420
W x L x H24 x 3050 x 24
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The wall angle should be fixedat max. 300 mm centres. Atcorners the tr im should be mitredaccurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.Note: The underside of thefinished ceiling will be 11 mmlower than the underside of the
wall tr im.
S u s p e n s i o n H a n g e r s The adjustable hangers should befixed with eye screws, brackets orsimilar. If direct hangers are usedthey should be screwed to thesoffit. Start with the first hangernot more than 400 mm from thewall in the longitudinal directionof the main runner, and then at a
maximum of 1200 mm centres.If additional f ixtures are fixedto the suspension system, extrahangers should be used.
M a i n r u n n e r The profiles are fixed in parallelwith centres of 1200 mm, or600 mm. The main runners haveinterlocking tongues in both
ends and can therefore be lockedtogether.
C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect slot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The tiles are fitted into the system from below, with an upwardmovement.Slide in one side of the tile until it is supported by the grid, bring thetile level and then slide in the opposite side.
To demount ti les apply upward pressure. Slide the tile out, move itforward, to the side and then let the tile drop below.Gloves should be worn at all times when handling the tiles and a saw orknife used to cut the tiles to size.
Linear 600
A A
5/25/2018 KATALOG DANOLINE
20/13220
1269
5/25/2018 KATALOG DANOLINE
21/13221
Markant is the classic ceiling solution, featuring str ong
shaded markings between ceiling panels.
The ceiling will often be se en fitted into a pattern adapted
to the shape of the room, thus achieving a lightness and
dynamic of design.
The bevelled edges of the ceili ng panels ensure easy,
straightforward assembly, and combined with r ecessing into
the suspension system this provides a directionally stable
ceiling.
C l a s s i c a l c e i l i n g s o l u t i o n a c h i e v e d w i t h M a r k a n t ,6 0 0 m o d u l e s a l l o w u p g r a d i n g t o s w i n g f u n c t i o n
1269:
Architect: Dissing og Weitling
Project: Rdhusparken, Glostrup - Denmark
Product: Markant 600 - M1
9999:
Architect: Interoc, StockholmProject: Konferensrum Interoc, Stockholm - Sweden
Product: Markant 600, Swing
0990:
Architect: Fich og Bengaard
Project: Knud Engsig A/S, Aalborg - Denmark
Product: Markant 500 - G1
Markant 500 and Markant 600
0990
99999999
5/25/2018 KATALOG DANOLINE
22/132
600
Max.600
600
Max.600
6001200
22
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations..
P r o d u c t
Sizes
600 x 600 x 12.5 mm
600 x 1200 x 12.5 mm
625 x 625 x 12.5 mm
625 x 1250 x 12.5 mm
Other sizes on request.
600 x 600 x 12.5 with swing function, S24
D r a f t s p e c i f i c a t i o n ,
Danoline Markant 600, G1, 600 x 600 x 12.5 mm,
(12.5 x 610 x 610 mm) White painted as standard,
for exposed suspension systems 15/24 mm for module
600 (24 mm for module 610).
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 600 mm, and shall be made
from 1200 mm cross-Tees. The suspension hanger must be
fixed to the main runner at 1200 mm centres and not le ss
than 400 mm from the wall angle.Measurements are in mm.
Drawing no.: 20
D e t a i l
Markant 600, with fr ieze of Plaza 600 Regula.
Drawing no.: 20.2.003
Markant 600, with wall tr im.
Drawing no.: 20.2.011
Markant 600, with shadow edge trim.
Drawing no.: 20.2.004
Markant 600 with painted fix frieze of gypsum boardscrew-fixed on 35 mm T-profile.Drawing no.: 20.2.002
5/25/2018 KATALOG DANOLINE
23/13223
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
85030
W x L x H
24 x 3600 x 38
MAIN RUNNER
Part no.
750030
W x L x H
15 x 3000 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
85130
85230
85430
W x L x H
24 x 300 x 38
24 x 600 x 38
24 x 1200 x 38
CROSS TEE
Part no.
751130
751230
751430
W x L x H
15 x 300 x 38
15 x 600 x 38
15 x 1200 x 38
WALL ANGLE
Part no.
1420
W x L x H
24 x 3050 x 24
WALL ANGLE
Part no.
1438
W x L x H
19 x 3050 x 32
SHADOW LINE
EDGE TRIMPart no.
1459
W x L x H10 + 24 x 3050 x 12 + 19
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and
then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.
C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the
tiles and a saw or knife used tocut the tiles to size.
M a i n r u n n e r The main runners are installedparallel to each other at distances1200 mm, or 600 mm, c/cdepending on system module.
The main runners haveinterlocking tongues in both ends,and can be locked together.
Markant 600
A A
5/25/2018 KATALOG DANOLINE
24/132
500
Max.500
500
Max.500
5001000
24
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
500 x 500 x 9.5 mm
D r a f t s p e c i f i c a t i o n ,
Danoline Markant 500, G1, 500 x 500 x 9.5 mm,
White painted as standard, for exposed 15 mm suspension
systems.
Measurements are in mm.
Drawing no.: 25
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 500 mm, and shall be made
from 1000 mm cross-Tees. The suspension hanger must be
fixed to the main runner at 1000 mm centres and not le ss
than 400 mm from the wall angle.
D e t a i l
Markant 500 with perimeter of cut Markant Regula.
Drawing no.: 25.2.001
Markant 500 with perimeter of Plaza Regula.Drawing no.: 25.2.002
5/25/2018 KATALOG DANOLINE
25/13225
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
750010
W x L x H
15 x 3000 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
751210
751410
W x L x H
15 x 500 x 38
15 x 1000 x 38
WALL ANGLE
Part no.
1438
W x L x H
19 x 3050 x 32
SHADOW LINE
EDGE TRIM
Part no.1459
W x L x H
12 + 19 x 3050 x 10 + 24
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300mmcentres. At corners the angleshould be mitred accurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and
then at a maximum of 1000mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.
C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the
tiles and a saw or knife used tocut the tiles to size.
M a i n r u n n e r The main runners are installedparallel to each other at distances1000 mm, or 500 mm c/cdepending on system module.
The main runners haveinterlocking tongues in both ends,and can be locked together.
Markant 500
A A
5/25/2018 KATALOG DANOLINE
26/13226
1201
5/25/2018 KATALOG DANOLINE
27/13227
Belgravia is the ceiling with a grid system that is semi-
recessed. Supplied with tegular and bevelled edges, the
tiles guarantee a very directionally stable ceilin g and are
less sensitive to damaging the edges.
As they are being installed, they fall into place in the
suspension system with distinct ease and simplicity.
E a s y a n d e f f o r t l e s s p e r f o r m a n c e s e c u r e d b y t h e g e o m e t r i c a l c h a r a c t e r i s t i c s o f B e l g r a v i a
1201:
Architect: Arkkitehtitoimisto Larkas & Laine Oy
Project: Kontor bygning, Outokumpu - Finland
Product: Belgravia 600 - Stardust
1198:
Architect: Suunnittelukeskus OyProject: Sygehus, Kerava - Finland
Product: Belgravia 600
1131:
Architect: MA Arkitekter Bors
Project: hlenshuset, Bors - Sweden
Product: Belgravia 600 - M1
Belgravia 600
1131
1198
5/25/2018 KATALOG DANOLINE
28/132
600
Max.600
600
Max.600
6001200
28
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 600 x 12.5 mm
625 x 625 x 12.5 mm
D r a f t s p e c i f i c a t i o n
Danoline Belgravia 600, M1, 600 x 600 x 12.5 mm, (610
x 610 x 12.5 mm) white painted as standard, for exposed
suspension systems 15 mm system for module 600 (24
mm system for module 610).
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 600 mm, and shall be made
from 1200 mm cross-Tees. The suspension hanger must be
fixed to the main runner at 1200 mm centres and not le ss
than 400 mm from the wall angle.
D e t a i l
Belgravia 600, with shadow line edge tr im - S15
Drawing no.: 22.2.004
Belgravia 600, with shadow line edge tr im - S24
Drawing no.: 22.2.005
Measurements are in mm.
Drawing no.: 22
5/25/2018 KATALOG DANOLINE
29/13229
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
750030
W x L x H
15 x 3000 x 38
MAIN RUNNER
Part no.
85030
W x L x H
24 x 3600 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
751130
751230
751430
W x L x H
15 x 300 x 38
15 x 600 x 38
15 x 1200 x 38
CROSS TEE
Part no.
85130
85230
85430
W x L x H
24 x 300 x 38
24 x 600 x 38
24 x 1200 x 38
WALL ANGLE
Part no.
1438
Bx L x H
19 x 3050 x 32
WALL ANGLE
Part no.
1420
Bx L x H
24 x 3050 x 24
SHADOW LINE
EDGE TRIMPart no.
1466
W x L x H15 + 15 x 3050 x 8 + 25
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are painted
in CMC 001 Global white
(equivalent to NCS 0902
G48Y). Suspension grid
available in ultraline, contact
technical department.
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this also makes
installation quicker and easier. It will also be easier to carry o ut inspections to installations above the ceiling as removal of the
tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and
then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.
C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the
tiles and a saw or knife used tocut the tiles to size.
M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending on system module.
The main runners haveinterlocking tongues in both ends,and can be locked together.
Belgravia 600
A A
5/25/2018 KATALOG DANOLINE
30/13230
1317
5/25/2018 KATALOG DANOLINE
31/13231
The setting of a Plaza ceiling is maybe best highlighted by
using a narrow gr id system.
Plaza 600 is fast and easy to mount and adapt, as all
edges remain hidden above the grid system.
Plaza 600 is often used as a frieze/margin panel for
Markant and Linear. Plaza 600 combines the qualities of
gypsum with favourable pricing.
P l a z a i s t h e s i m p l e d e s i g n w h i c h c a n b ec o m b i n e d w i t h c o n s i s t e n t p e r f o r a t i o n s
1317:
Architect: Initiative in DesignProject: Sir Williams Perkins School - UK
Product: Plaza 600 - M1
1210, 1211, 1212:
Architect: H & M Arkkitehdit Oy
Project: School Veikkola - Finland
Product: Plaza 600 - M1
Plaza 600
1212
1210
1211
5/25/2018 KATALOG DANOLINE
32/132
600
Max.600
600
Max.600
6001200
32
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 600 x 9.5 mm
600 x 1200 x 9.5 mm
600 x 600 x 12.5 mm
600 x 1200 x 12.5 mm
625 x 625 x 12.5 mm
625 x 1250 x 12.5 mm Other sizes on request.
D r a f t s p e c i f i c a t i o n ,
Danoline Plaza 600, M1, 600 x 600 x 9.5 mm,
(610 x 610 x 9.5 mm) White painted as standard, for
exposed suspension systems 15/24 mm system for module
600 (15/24 mm system for module 610)
Measurements are in mm.
Drawing no.: 30
D e t a i l
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 600 mm, and shall be made
from 1200 mm cross-Tees. The suspension hanger must be
fixed to the main runner at 1200 mm centres and not le ss
than 400 mm from the wall angle.
Danoline recommends the use of suspension systems with
straight connections between main runners and cro ss tees,
so any differences in levels are avoided, i.e. the suspension
systems components are all in the same level.
Plaza 600 with wall tr im.
Drawing no.: 30.2.001
Plaza 600 with shadow line edge tr im.
Drawing no.: 30.2.002
5/25/2018 KATALOG DANOLINE
33/13233
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
750030
W x L x H
15 x 3000 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
751130
751230
751430
W x L x H
15 x 300 x 38
15 x 600 x 38
15 x 1200 x 38
WALL ANGLE
Part no.
1438
Bx L x H
19 x 3050 x 32
SHADOW LINE
EDGE TRIMPart no.
1459
W x L x H12 + 19 x 3050 x 10 + 24
Alternative suspension S24 see Markant 600.
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and
then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.
C r o s s - T e e s The Cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the Cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the
tiles and a saw or knife used tocut the tiles to size.
M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending on system module.
The main runners haveinterlocking tongues in both ends,and can be locked together.
Plaza 600
A A
5/25/2018 KATALOG DANOLINE
34/13234
1300
1306 1321
5/25/2018 KATALOG DANOLINE
35/13235
Danoline Tiles are mounted with a visible Lay-in grid system.
The ceiling panels look like a smooth, white faced surface,
which is environmentally friendly and ensures gre at usability
in rooms with re latively high humidity.
The surface is easy to maintain and will therefore withstand
rough washing, as it has a good mechanical resistance.
Apart from Danoline Tiles fine qualities, it is also an
economically advantageous solution.
D u r a b l e s u r f a c e s a n d g o o d e c o n o m y a c c o m p l i s h e d w i t h t h e s i m p l e p r o d u c t D a n o l i n e T i l e s
1306:
Architect: Aukett Ltd, London
Project: SAS Radisson, Stansted, - UKProduct: Danoline Tiles 600 - White
1321:
Architect: Bluestone
Project: ABL Factory/ warehouse - UK
Product: Danoline Tiles 600 - White
1300:
Architect: Kinnersley Kent Design, London
Project: House of Fraser, Croydon, Surrey - UK
Product: Danoline Tiles 600 - White
1119:
Project: Close up
Product: Danoline Tiles 600, White
1120:Project: Close up
Product: Danoline Tiles 600, Metallic
1122:
Architect: Arkitektkontoret Waage as, Bergen
Project: Amficenter Voss, Bergen - Norway
Product: Danoline Tiles 600, Metallic
Danoline Tiles 600, White and Metallic
1122
11201119
5/25/2018 KATALOG DANOLINE
36/13236
1109
5/25/2018 KATALOG DANOLINE
37/13237
Danoline Tiles Medley is mounted in a visible Lay-in grid
system. The tiles are available with squared or rebated
edges.
The ceiling tiles appear like a smooth tinted laminated
surface. It is environmentally friendly and ensures gr eat
usability in rooms with relatively high humidity.
The surface is easy to maintain as it can withstand rough
washing, because of the good mechanical resistance in
the surface. Danoline Tiles Medley offers good i nherent
properties and it is also an economically advantageous
solution.
P e r f o r a t e d D a n o l i n e T i l e s M e d l e y c o m p l e t e w i t h e d g e d e t a i l s a n d f o i l s u r f a c e
1109, 1111, 1114, 1117:
Architect: Villum Kirkegaard
Project: Kontor, Hobro - Denmark
Product: Danoline Tiles 600 - Medley
Danoline Tiles 600, Medley
1114
11171111
5/25/2018 KATALOG DANOLINE
38/132
600
Max.600
600
Max.600
6001200
38
S u r f a c e
Regula R, Laminated white, metallic and medley
foil. Medley is also available with Globe G1
perforation.
P r o d u c t
S i z e s
600 x 600 x 6.5 mm
600 x 1200 x 6.5 mm
600 x 600 x 9.5 mm
600 x 1200 9.5 mm
625 x 625 x 9.5 mm
Other sizes on request.
D r a f t s p e c i f i c a t i o n ,
Danoline Danoline Tiles 600, R, 600 x 600 x 6.5 mm,
Laminated type white 600 x 600 x 6.5 mm for exposed
15/24 mm suspension systems
Measurements are in mm.
Drawing no.: 40
D e t a i l
Danoline Tiles 600 with wall tr im.Drawing no.: 40.2.001
Danoline Tiles 600 with shadow line edge tr im.
Drawing no.: 40.2.002
S u s p e n s i o n s y s t e m
Cut cross-Tees may not exceed 600 mm, and shall be made
from 1200 mm cr oss-T ees. The suspension hanger must be
fixed to the main run ner at 1200 mm centres and not less than
400 mm from the wall angle.
Danoline recommends the use of suspension systems with
straight connections between main runners and cro ss tees,
so any differences in levels are avoided, i.e. the suspension
systems components are all in the same level.
E d g e
A
A
A / E - Medley G1 and R
A
A
5/25/2018 KATALOG DANOLINE
39/13239
C o m p o n e n t s
I n s t a l l a t i o n
MAIN RUNNER
Part no.
750030
W x L x H
15 x 3000 x 38
ADJUSTABLE HANGERS
Part no. Length
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
CROSS TEE
Part no.
751130
751230
751430
W x L x H
15 x 300 x 38
15 x 600 x 38
15 x 1200 x 38
WALL ANGLE
Part no.
1438
Bx L x H
19 x 3050 x 32
SHADOW LINE
EDGE TRIMPart no.
1459
W x L x H12 + 19 x 3050 x 10 + 24
Alternative suspension S24 see Markant 600.
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are painted
in CMC 001 Global white
(equivalent to NCS 0902
G48Y).
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right angles, this makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
L a y o u t Generally start setting out fromthe centre of the room ensuringthat perimeter edge cuts areof equal size on both sides ofthe room.The positioning of light fittings,ventilation units and sprinklerheads should be considered at
this stage.
W a l l T r i m The perimeter tr im is f ixed tothe wall at maximum 300 mmcentres. At corners the angleshould be mitred accurately.
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
S u s p e n s i o n H a n g e r s The adjustable hangers shouldbe fixed with eye screws, anglebrackets or similar. If directhangers are used they should bescrewed to the soffit. Start with thefirst hanger not more than 400 mmfrom the wall in the longitudinaldirection of the main runner, and
then at a maximum of 1200 mmcentres. If additional fixtures arefixed to the suspension system,extra hangers should be used.
C r o s s - T e e s The cross-Tees are installed byinserting snap-in tongues into thecorrect s lot on the stalk of themain runner and are locked into
position by a slight downwardpressure. If the cross-Tee is notcontinued into the adjoiningmodule, the tongue has to besplit and bent flat.
C h e c k i n g t h eS u s p e n s i o n S y s t e m When the suspension systemis installed, the levels andangles should be checked and
if necessary the hangers adjusted.
T i l e s The level of the tiles should bechecked when the installation iscompleted. Gloves should be wornat all times when handling the
tiles and a saw or knife used tocut the tiles to size.
M a i n r u n n e r The main runners are installedparallel to each others atdistances 1200 mm, or 600 mm,c/c depending of system module.
The main runners haveinterlocking tongues in both ends,and can be locked together.
Danoline Tiles 600
A A
5/25/2018 KATALOG DANOLINE
40/13240
A demand for a higher sound reduction (STC) can be
required if the drywalls or partitions are not extended to
the soffit of the deck, but to the suspended ceiling on ly.
The construction therefore provides gr eat freedom of choice
with regard to creating or moving walls.
S y s t e m s
Danopor is available for ceiling products with
edge D, C, E, and A.
S i z e s
600 x 600 x 25 mm
600 x 600 x 50 mm
Other sizes on request.
D r a f t s p e c i f i c a t i o n
Danoline Danopor is installed on the back of
Plaza 600, M1, 600 x 600 x 9.5 mm white
painted as standard in 15/24 mm exposed
suspension system.
Product:
Edge:
Suspension:
Contur 600
D
S2 4
Linear 600
C
S2 4
Belgravia 600
E
S15/S24/Ultraline
Markant 600
E
S15/S24
Plaza 600
A
S15/S24
5/25/2018 KATALOG DANOLINE
41/13241
The natural properties of gypsum ensure that the Danoline
products have a good sound reduction in low frequencies.
In combination with Danapor a low density insulation pad
placed inside sealed PE-faced bags and positioned on the
back of the Danoline products a good result with sound
reduction of both low, medium and high frequencies from
room to room can be achieved.
Sound-reducing characteristics can be varied further by
selecting different thicknesses of Danopor. In addition to its
sound-reducing properties, the construction also has good
sound-absorbent properties throughout the frequency range.
In particular the bass frequency sound absorption is good.
I n c r e a s e d s o u n d r e d u c t i o n a n d a b s o r p t i o n r e a c h e d w i t h D a n a p o r w i t h o u t a f f e c t i n g
d e s i g n a n d e x p r e s s i o n
1267:
Architect: Berg Arkitekter
Project: Frsvarshgskolan, Stockholm - Sweden
Product: Markant 600 - M1
Danopor
1267
5/25/2018 KATALOG DANOLINE
42/13242
1179
5/25/2018 KATALOG DANOLINE
43/13243
Corridor gives the appearance of fine lin e markings in a
rectangular plank pattern. The ceiling is pri marily used in
corridors and is self-supporting for up to 2.4 m between
walls.
Corridor is often used in small utility and ancill ary rooms
for reasons of design and/or economy. Demounting reveals
a completely free area without transverse suspension
sections, optimal for work on technical installations.
The ceiling panels can either be delivered to the building
site and adjusted in situ or supplied in fixed dimensions.
Fixed dimensions reduce wastage as well as building waste,
making assembly faster and thus ch eaper.
1195:
Architect: Suunnittelukeskus Oy, Helsinki
Project: Health care centre Kerava, Helsinki - Finland
Product: Corridor 300
1176, 1177, 1179:
Architect: White Arkitekter
Project: Halmstads Fastighetsbolag - Sweden
Product: Corridor 300 - M1
N e w a r c h i t e c t u r a l p o s s i b i l i t i e s c r e a t e d b y t h e u n i q u e y e t s i m p l e d e s i g n o f C o r r i d o r
Corridor 300
1195
11761177
5/25/2018 KATALOG DANOLINE
44/132
Max.24
00
44
Measurements are in mm.
Drawing no.: 35
D e t a i l
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
300 x 1200 x 9.5 mm
300 x 1500 x 9.5 mm
300 x 1800 x 9.5 mm
300 x 2100 x 9.5 mm
300 x 2400 x 9.5 mm
Can be manufactured to special length, max. 2400 mm.
D r a f t s p e c i f i c a t i o n
Danoline Corridor 300, M1, 300 x 1200 x 9.5
mm, 300 x 2400 x 9.5 mm. White painted as
standard.
Installed on reinforced shadowline trim 1469.
S u s p e n s i o n s y s t e m
The flexprofile is an integrated part of the Corridor ceiling
plank. Main Tee runner is used between se ctions and lines
of Corridor planks, when the distance between the walls is
greater than 2400 mm.
Corridor 300. Joining of 2 short-edges using main runner65020.Drawing no.: 35.2.003
Corridor 300 with shadow line edge tr im 1469.
Drawing no.: 35.2.005
Corridor 300 with wall tr im.Drawing no.: 35.2.004
5/25/2018 KATALOG DANOLINE
45/13245
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise stated,
see section Moisture . It is equally important to take account of other work such as technical installations before installation
of the ceiling is carried out. It is important for the end result that the ceiling tiles are installed at right-angles, t his makes
installation quicker and easier. It will facil itate inspections to installations above the ceiling as removal of the tiles will be
easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
C o m p o n e n t s
FLEX RUNNER
Delivered in loose
parts with the
elements
W x L x H
65 x 1194 x 44
65 x 1494 x 44
65 x 1794 x 44
65 x 2094 x 44
65 x 2394 x 44
ADJUSTABLE HANGERS
Part no. Lenght
11022 120-200
11030-99 200-270
11030 250-320
11040 250-440
11070 380-690
11090 500-940
11120 750-1210
11150 750-1440
11200 1000-1940
MAIN RUNNER
Part no.
65020
W x L x H
35 x 3600 x 38
SHADOWLINE TRIM
Part no.
1469
W x L x H
20 + 20 x 3050 x 20 + 20
WALL ANGLEPart no.
1430
W x L x H
20 x 3050 x 40
I n s t a l l a t i o n
C o m p o n e n t s
Suspension grid, hangers
etc. are made from
galvanised steel. The
exposed sections are
painted in CMC 001 Global
white (equivalent to NCS
0902 G48Y).
S e t t i n g o u t The position of the wall trimshould be marked on the wallsand columns. The bottom flangeof the perimeter tr im is the levelof the proposed ceiling.
L a y o u t The ceiling is normally dividedin the centre, in this way theadjustments are the same size.Please note that the placing offixtures and ventilation units canaffect the correct layout
S u s p e n s i o n h a n g e r s Where there is a change ofdirection in the corridor, asuspended main runner must beused to support the planks. Themaximum distance between thesuspension hangers is 750 mm,and a maximum 300 mm fromthe walls.
W a l l T r i m The perimeter tr im is fixed tothe wall at max. 300 mm. Atcorners the tr im should be mitredaccurately.
M a i n R u n n e r 6 5 0 2 0Main Runner 65020 can be usedto support Corridor planks atmaximum 2400 centres.It is necessary to secure themain runner at the perimeter,
and to fix the Flex profile tothe main runner at every sixthplank. Where the short edges ofthe Corridor plank abut the mainrunner, the Flex profiles on eitherside of the Tee are secured toeach other.
P l a n k s Where possible, Corridor planksshould be installed after all majorwork in the ceiling void has beencompleted. The flex-profile mustnot be over 6 mm shorter than
the planks. The level of the tilesshould be checked when theinstallation is completed. Glovesshould be worn at all times whenhandling the tiles and a saw orknife used to cut the tiles to size.
A d j u s t i n g t h e F l e xp r o f i l eIf the flex profile is brokenbecause of fittings, installationsor other implementations, theFlex profile has to be suspended.
L e v e l l i n g t h eS u s p e n s i o n S y s t e m If suspension hangers have beenused, they must be adjusted toobtain an accurate level. Wherethere is a change in direction of
planks, the main runner must besecured to the wall construction.
Corridor 300
5/25/2018 KATALOG DANOLINE
46/13246
0563
5/25/2018 KATALOG DANOLINE
47/13247
The panels consist of long-format panels with an effective
span of up to 2.8 m. Corridor F30 has the appearance
of fine stroke markings in a rectangular plank pattern.
The product has been styled to cope with the tough
fire requirements set out in DIN 4102 (see section on
properties).
The unique quality about Corridor F30 is that it is the
only ceiling without mineral wool to comply with this fire
requirement.
As a result of its fire properties, the ceiling provides great
safety and is an obvious choice for use in e scape routes.
0563, 0564, 0560:
Architect: Hupach und Partner
Project: DESY, Hamburg - Germany
Product: Corridor F30
E x c e l l e n t f i r e p r o p e r t i e s y e t d i s c r e e t j o i n t s b e t w e e n t h e e l e m e n t s c r e a t e d w i t h C o r r i d o r F 3 0
Corridor F30
0560
0564
5/25/2018 KATALOG DANOLINE
48/13249
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless oth erwise stated, see section Moisture . It is
equally important to take account of other work such as technical installations before installation of the ceiling is carried out. It is important for the end result
that the ceiling tiles are installed at righ t-angles, this makes installation quicker and easier. It will facil itate inspections to installations above the ceiling as
removal of the tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
C o m p o n e n t s
WALL ANGLE
Part no.
F3000012
W x L x H
40 x 3000 x 60
I n s t a l l a t i o n
C o m p o n e n t s
The wall profiles are made
from aluzinc. Painted to
RAL 9016
S e t t i n g o u t The position of the wall anglesshould be marked on the wallsand columns. The bottom flangeof the wall angles is the levelof Corridor planks. Fixation withscrews at max 400 mm c/c.
A d j u s t m e n tThe Corridor panels are crosscut with a jigsaw for metal.Longitudinally cuts are made witha normal saw.
F i r e c a p Into the back of the panel asquare furring cap is inserted.This must close the openings intothe Corridor panel.
A i r i n l e t s a n do u t l e t s Cutting out for opening is doneby a jigsaw, from the front side.Final adjustment by a fine toothsaw or a Stanley knife.
L i g t h f i x t u r e s Installation of 300 mmlightfixture. This installationrequires a special Corridor panelwith an extra layer of gypsumboard. The cut end adjacent tothe luminarie shall be fil led outby GKF gypsum board. On the
back of the light fixture a GKFgypsum board shall be fixed, andthe 3 elements are now installedbetween 2 standard panels. Thelight fixture also has to be screwfixed to the 2 adjacent panels.
W a l l t r i m The wall angles shall be furredby Fireboard srips of 120 mm.At elements which are cutlongitudinal an extra strip ofFireboard shall be fixed. Fixationby drywall screw.
L a y - i nThe Corridor panels are laid indirectly on the wall angles. Thepanels are self-supporting to2800 mm free span.
E n d - e l e m e n t s Measurement A for the secondlast panels is set, and themeasurement B is made for thelast panel. The end panel isthen cut to size and is laid inon the wall angle with the extraFireboard str ip.
C l o s i n g The second last panel can nowbe laid in between the end paneland the third last panel.Cotten gloves should be wornat all time when handling theCorridor panels.
L i g t h f i x t u r e s Installation of light fixture lessthan 300 mm. Cut out for thesize of the light fixture. All openend in the panels to be closedby GKF gypsum board, whichshall be screw fixed to the metalprofile in the panel. If necessary,
additional metal profile is addedto secure the gypsum fil l -out.Fill -out gypsum strips to be screwfixed. The light fixture shall bescrew fixed to the panel. On theback of the panel an additionallayer of GKF board shall be fixed.
F i r e c a p f i x i n g The fire protection cap shall befixed with angle brackets, andthe void between the cap andthe air inlet/outlet shall be fil ledwith gypsum mortar.
A B
Corridor F30
5/25/2018 KATALOG DANOLINE
49/13250
1266
5/25/2018 KATALOG DANOLINE
50/132
Max.28
00Max
.2800
48
Measurements are in mm.
D e t a i l
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
P r o d u c t
S i z e s
300 x (length) x 12.5 x mm
Max. Length 2800 mm.
D r a f t s p e c i f i c a t i o n
Danoline Corridor F30, White laminated as
standard, Installed on wall angle F3000012.
Drawing no.: 36
S u s p e n s i o n s y s t e m
Corridor F30 is a selfsupporting cei ling system with
integrated steel profiles, making a free span of max. 2800
mm
Corridor F30, adjustment panel at wall angle, and withgypsum shadow edge trim.Drawing no.: 36.2.004
Corridor F30, jointing of long-edge against short edge.
Drawing no.: 36.2.003
Corridor F30 fixed with wall angle at gypsum boards onsteel structure.Drawing no.: 36.2.001
Corridor F30 panels with wall angle and gypsum boardshadow trim.Drawing no.: 36.2.002
5/25/2018 KATALOG DANOLINE
51/13251
Corridor swing is a hinged cei ling construction whereby
apertures on all four lateral edges achie ve a rough yet
floating, light design.
The panels are rectangular in appearance, with l engths
of up to 1.8 m. Corridor Swing is fitted with a hinge and
swivels down without the use of tools.
The panel remains suspended during inspection work,
allowing simple and fast access to installations.
D i s t i n c t i v e p e r f o r a t i o n s f a v o u r t h e f u n c t i o n a l d e s i g n o f C o r r i d o r S w i n g 6 0 0
1266:
Architect: Arkitektgruppen Aarhus
Project: Greve Rdhus - Denmark
Product: Corridor Swing - M1
1156, 1158:
Architect: White Arkitekter Gteborg
Project: Medicinskt Kunskapshus, Gteborg - Sweden
Product: Corridor Swing - M1
Corridor Swing 600
1158
1156
1158
5/25/2018 KATALOG DANOLINE
52/132
1200,15
00,1800
600
1200,15
00,1800
600
52
Measurements are in mm.
D e t a i l
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 1200 x 12.5 mm
600 x 1500 x 12.5 mm
600 x 1800 x 12.5 mm
D r a f t s p e c i f i c a t i o n
Danoline Corridor Swing 600, G1,
600 x 1200 x 12.5 mm, installed in suspension
system 721000.
Drawing no.: 52
S u s p e n s i o n s y s t e m
The Swing profiles on the walls and the suspended friezes
to be installed as per module of Corridor 600
Corridor Swing 600, joint of 2 short-edges with profileW-Swing 3.Drawing no.: 52.2.003
Corridor Swing 600 with fix fr ieze of painted Mitex panel.
Drawing no.: 52.2.001
Corridor Swing 600, longitudinal joint between 2 panels.
Drawing no.: 52.2.002
5/25/2018 KATALOG DANOLINE
53/13253
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless oth erwise stated, see section Moisture . It is
equally important to take account of other work such as technical installations before installation of the ceiling is carried out. It is important for the end result
that the ceiling tiles are installed at righ t-angles, this makes installation quicker and easier. It will facil itate inspections to installations above the ceiling as
removal of the tiles will be easier. It is not recommended that ceil ings are installed at a temperature consistantly over 50C.
PROFILE W-SWING 1 / WHITE PAINTED
Part no.
729196
W x L x H
8/12 x 2400 x 55
PROFILE W-SWING 5 / WHITE PAINTED
Part no.
729200
W x L x H
68 x 2400 x 53
PROFILE W-SWING 2 / WHITE PAINTED
Part no.
730162
W x L x H
40 x 2400 x 16
METAL CLIP / GALVANIZED
Part no.
721175
W x L x H
70 x 58 x 80
PROFILE W-SWING 3 / WHITE PAINTED
Part no.
729198
W x L x H
92 x 2400 x 16
SCREW/NUT W34 / GALVANIZED
Part no.
718473
PROFILE W-SWING 4A / WHITE PAINTED
Part no.
731618
(Combined with W-swing 2)
W x L x H
85 x 2400 x 66
SWING HANGER / UNPAINTED
Part no.
SW6MB
Incl. element
4 x 582 x 53
I n s t a l l a t i o n
C o m p o n e n t s
C o m p o n e n t s
Profiles and accessories
are made from galvanised
steel. The painted sections
are painted in RAL 9010
(equivalent to NCS 0502
Y14R).
P l a n n i n g t h ec e i l i n g s u r f a c e The module measurement is24 mm larger than the actualelements. When installed therewill be 24 mm gab around alledges of the element.
P r o f i l e d i s t a n c e s The W swing 2 profiles are installedunder the metal clips with the W34clip. Now the distance betweenthe suspension points on the Wswing 2 profiles must be adjusted,so the distance between them isthe length of the element minus 50mm. The two swing profiles must beinstalled, so the suspension pointsare directly opposite each other due
to the following installation of theactual elements.
F i x i n g o f t h e m e t a lc l i p The metal clip is fixed to the wallor vertical steel profiles at c/c800 mm. The lowest edge ofthe metal clip should be 65 mmhigher than the desired ceiling
height. It is very important thatthe frame work is rigid so itcannot deform the elements wheninstalled.
D i m e n s i o n a l o u t l i n e ,D i s m o u n t a b l e f r i e z e M indicate module line. There mustbe a 12 mm gap towards the Corridorswing element and a 18 mm gapto the frieze. Horizontal U-profilesand vertical C-profiles are installedin order to create a rigid fr ame forthe swing profiles. W-swing 2 and4A profiles are fixed at c/c 800 mmin the vertical steel profiles with the
W34 bolt. The wall angle is fixed tothe wall at c/c 400 mm.
F i n i s h i n g t h ei n s t a l l a t i o n The element is swung up tohorizontal level and the hangersare held in vertical position soit can be slid into the W-swing2 profile.
I n s t a l l a t i o n o f t h ee l e m e n t s The ceiling elements are hungalong one of the sides to beginwith. The element is kept verticalwith the hanger pointing up andthe hanger is clasped on the
W-swing 2 profile.
I n s t a l l a t i o n o fs w i n g h a n g e rS W 6 M B The swing hanger is fixed tothe fastened SW15 profile,the other SW15 swing profileis pushed into its slot, so the
hanger is fixed in the hole ofthe SW15 profile. Now the otherSW15 profile can be fixed usingprevious described method. Itis not recommend installing thehanger by tensioning as it willgive an inappropriate sidewaysforce on the SW15 profiles.
D i m e n s i o n a l o u t - l i n e , w a l l j u n c t i o n M indicates the module line.There must be a 12 mm gap oneach side of M. The metal clip,721175 is fixed to the wall at800 c/c mm and the W-swing 2profile is fixed to the metal clipwith the W34 bolt.
D i m e n s i o n a l o u t - l i n e , F i x e d f r i e z e M indicates the module line.There must be a 12 mm gap oneach side of M. The metal clip,721175 is fixed to the verticalprofiles and horizontal U-profilesare installed so the fixed friezecan be screwed onto them. TheW-swing 2 profile is fixed to themetal clip with the W34 bolt.
A s s e m b l y o f t h ee l e m e n t s The elements come withdepressed fittings. The SW15profiles are fixed with thesupplied screws through thedepressed fitting into the
element. The distance betweenthe end of the profile to the edgeof the element must be 15 mm.Only one SW15 swing profile isfixed at this stage. The base forfixing the load bearing profilesmust be plane and solid. Theremust be no deflection of theprofile during the fixing of it.
Corridor Swing 600
M MM
50 mm
I n s t a l l a t i o n o fS w i n g c r o s s p r o f i l eThe cross profile is placed ontothe metal clip so that the hole inthe cross profile is directly abovethe centre hole in the metalclip. The foil cover is removed
from the adhesive pads and thecross profile is pressed tightlyagainst the element. The screwis fixed through the hole in theprofile and the centre hole in themetal clip.
5/25/2018 KATALOG DANOLINE
54/13254
1072
5/25/2018 KATALOG DANOLINE
55/13255
Danopanel, like Contur, features a monolithic, linedivided
surface.
The panelling is supplied ready painted and fitted without
visible screws. Since there is no handling by painters,
installation time is short, achieving a good overall
economy.
Direct screwing onto the metal furring system/timber
battens ensures a low construction height.
P r o p e r t i e s a n d m a t e r i a l s u n i t e d i n h a r m o n y t o c r e a t e t h e s i m p l e a n d p u r e l i n i n g c e i l i n g D a n o p a n e l
1072:
Architect: Asger Bergo Friis
Project: Ruds Vedby Skole SFO - Denmark
Product: Danopanel - Q1
1276:
Architect: Arkitekt Erik Eriksen
Project: Daginstition, Maglekrvej, Grlse - Denmark
Product: Danopanel - G1, R
Danopanel
1276
5/25/2018 KATALOG DANOLINE
56/132
600
600
300
300
56
Measurements are in mm.
Drawing no.: 61
D e t a i l
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
Other perforation patterns are manufactured to
order. Please see section Perforations.
P r o d u c t
S i z e s
600 x 600 x 12.5 mm
D r a f t s p e c i f i c a t i o n
Danoline Danopanel, G1, 600 x 600 x 12.5 mm.
White painted as standard Installed on metal or
wooden furring system.
Danopanel, fr ieze connection.
Drawing no.: 61.2.001
F u r r i n g s y s t e m
The Danopanel must be screw fixed to furring of
25 x 100 mm wood battens at 300 mm c/c.
5/25/2018 KATALOG DANOLINE
57/13257
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise
stated, see section Moisture . It is equally important to take account of other work such as technical installations before
installation of the ceiling is carried out. It is important for the end result that the ceili ng tiles are installed at right-
angles, this also makes installation quicker & easier. It is not recommended that ceilings are installed at a temperature
consistantly over 50C.
I n s t a l l a t i o n I n s t a l l a t i o n
Danopanel is screwed to the furring system using a plain-
end screw, wood furring no. TA35, steel furring MSB15SB.
It should be noted that the panels must be turned around
from row to row and this influences the position of the
middle furring piece.
L a y o u t Generally start setting out fromthe centre of the room. TheDanopanels are installed on afurring of either wood or steel.The furring is spaced at 300mm c/c.
F r i e z eThe last row of tiles can also bescrew fixed directly through theDanopanel. The position of thescrews shall be max. 30 mm fromthe clips behind the panel.
A d j u s t m e n t s Cuttings and adjustments of thepanels can be carried out by afine tooth saw or a Stanley knife.If the last row is a full size panel,the clips should be cut . If thepanels have to be cut to a smallerwidth the clips shall be removedand re-fixed onto the cut panel.
I n s t a l l a t i o n Begin the installation of first rowfrom the centre of the room usinga chalk line. The Danopanels arescrew fixed through the holes inthe factory mounted clips. Onthe next rows of panels the clipscan slide in behind the adjacentpanels thus only screw fixing the
clips on the other side etc.
Danopanel
5/25/2018 KATALOG DANOLINE
58/13258
1079
5/25/2018 KATALOG DANOLINE
59/13259
Combipanel is a lining product that features fine markings
in rectangular plank patterns.
Combipanel comes with the s urfaces ready painted and
can be fitted in free bond as a result of an integral furring
system.
Combipanel only requires metal furring every 1000 mm and
can be fitted straight onto rafter constructions.
L o n g a n d s l i m d i m e n s i o n s m a k e C o m b i p a n e l u n i q u e
1079:
Architect: Claus B. Hansen
Project: Brndby Stadion - Denmark
Product: Combipanel - G1
0133:
Architect: Jrn Langvad A/S
Project: Q8 hovedkontor - Denmark
Product: Combipanel - G1
Combipanel
0133
5/25/2018 KATALOG DANOLINE
60/132
Max.1000
60
Combipanel, wall connection.
Drawing no.: 65.2.001
S u b s t r u c t u r e
Combipanel shall be fixed to a levelled substructure, which
can be directly to rafters or ceil ing joists without furring. If
furring is being used, it can be 25 x 100 mm wood battens
at 300 mm c/c.
Combipanel only needs to be screw fixed at each 1000mm.
Measurements are in mm.
Drawing no.: 65
D e t a i l
P e r f o r a t i o n
Globe: G1
Quadril: Q1
Micro: M1
Regula: R
P r o d u c t
S i z e s
300 x 1200 x 9.5 mm
300 x 1800 x 9.5 mm
300 x 2400 x 9.5 mm
D r a f t s p e c i f i c a t i o n
Danoline Combipanel, G1, 300 x 2400 x 9.5 mm
on metal or wooden furring system.
5/25/2018 KATALOG DANOLINE
61/13261
S t o r a g e & I n s t a l l a t i o n
Storage and installation should not be carried out in rooms with a relative humidity greater than 70%, unless otherwise
stated, see section Moisture . It is equally important to take account of other work such as technical installations before
installation of the ceiling is carried out. It is important for the end result that the ceili ng tiles are installed at right-
angles, this also makes installation quicker and easier. It i s not recommended that ceilings are installed at a temperature
consistantly over 50C.
I n s t a l l a t i o n
L a y o u t Generally start setting outfrom the centre of the room.The Combipanels are installeddirectly on a levelled substructure
max. 1000 mm c/c.
I n s t a l l a t i o n Begin the first row ofCombipanels in a corner of theroom with the groove of thepanels facing the room. Along
the wall screw fixing shall bethrough the panel. Along the walla 22 mm distance furring shallbe added. The enclosed metalS-profile shall be placed into thegroove, and screw fixing takeplace through the holes in theprofile only.
T h e S - p r o f i l e The enclosed s-shaped metalprofile shall be placed staggeredto the end joints of the panels.Screw fixing at max 1000
mm c/c.
E n d r o w For the last row of Combipanelsa 22 furring along the wall shallbe fixed. The last row of panelsare screw fixed direct through the
panels into the furring.
Combipanel
5/25/2018 KATALOG DANOLINE
62/13262
1246
5/25/2018 KATALOG DANOLINE
63/13263
The Designpanel products offer scope for a c eiling design
with large, continuous surfaces. Combined with acoustic
control, perforations are used, taking the shape of patterns
embossed almost plastically into the surface.
Designpanel are fitted with tapered edges along the long
edges, on request it can be made with tapered edges on all
four edges, giving an even and smooth intermediate joint
filling between panels and reducing cracking.
O p t i m u m m e t h o d f o r l a r g e c e i l i n g s m e a n s u s i n g D e s i g n p a n e l w i t h f o u r t a p e r e d e d g e s
1246:
Architect: Link Arkitekter, Oslo
Project: Nannestad skole - Norway
Product: Designpanael 1200 - Q2F
1153, 1154, 1155:
Architect: Semren Arkitektkontor Gteborg
Project: Bors Hjskole - Sweden
Product: Designpanael 900 - M1F
Designpanel 900 and 1200
1154
11551153
5/25/2018 KATALOG DANOLINE
64/132
300
900
3001000
64
Designpanel on wood or steel furring
respectively. Note that the short edge is
available with tapered edge.
F u r r i n g , s u s p e n d e d o n s t e e l
The ceiling is fitted onto a plane steel furring of the
CD-type. The system consists of primary and secondary
framework. The system is constructed with a central
distance of 300 mm perpendicularly lengthwise to the
Designpanel. All short edge joints must be supported.
As an alternative framework type MF5 and primary MF7
can be used.
P e r f o r a t i o n
Globe: (900) G1F, G2F ; (1200) G2F, G4F
Quadril: (900) Q1F, Q2F ; (1200) Q2F, Q4F
Micro: (900) M1F, M2F ; (1200) M2F
Regula: R
Other perforation patterns are manufactured to order.
Please see section Perforations.
P r o d u c t
S i z e s
900 x 2700 x 12.5 mm
1200 x 2400 x 12.5 mm
D r a f t s p e c i f i c a t i o n
Danoline Designpanel 900/1200, G1F,
900 x 2700 x 12.5 mm
1200 x 2400 x 12.5 mm
installed in metal or wooden furring system.
F u r r i n g , B D - 3 0 ( E I 3 0 ) c o n s t r u c t i o n
The ceiling is fitted onto a plane wooden furring 25 x 100
mm. The furring is fitted perpendicularly lengthwise to the
Designpanel. The maximum distance for the furring is 300
mm. All short edge joints must be supported.
D e t a i l
Designpanel on traditional furring,wall junction and boardconnection.Drawing no.: 62.2.001
Measurements are in mm.
Drawing no.: 62
Measurements are in mm.
Drawing no.: 62
Designpanel on CD steel furr ing system, wall junction andboard connection.Drawing no.: 62.2.002
5/25/2018 KATALOG DANOLINE
65/13265
Designpanel 900 and 1200
B D - 3 0 ( E I 3 0 ) c o n s t r u c t i o n
Damp proof barrier is placed over the furring. If the damp proof
membrane is placed immediately over the perforations, but under
the furring, the ability to absorb the sound is severely reduced.
The present absorption data depends on a 150 my () plastic
foil. A foil with any other thickness will affect the acoustic
capacities. In order to achieve a BD-30 construction, 250 mm
rock wool insulation must be a part of the construction.
F u r r i n g , w o o d
The ceiling is fitted to a plane wooden furring 25 x 100 mm.
The furring is fitted to the rafters or beams with a maximum
central distance of 1000 mm. The furring is
fitted perpendicular lengthwise to the ceiling
panel. The maximum c/c distance of the
furring is 300 mm. The short edges
of the panel joints must be
supported.
F u r r i n g , s t e e l
The ceiling is fitted to a plane s teel furring of the CD-2
type. The system consists of primary runners at max 900
mm c/c, and secondary runners at 300 mm c/c. Along
all walls and edges the wall profiles UD 28 x 27 are fixed
and secured to the furring at max 400 mm. The top partof the hangers, of the nonius model, are sec ured to the
above construction at 900 and attached
to the primary CD-60 runners
with the lower part of the
hanger. The cross connector i s
placed per 300 mm and the
underlying secondary profiles
are secured into them. The short e dges of the panel must
be supported along its entire lenght by fixing the panel to
the furring system.
G r o u p i n g
The starting point for the fitting of the desi gn panels is
where a level line can be achieved through the whole
fitting area. The first row is fitted along a s tring in order
for the perforated sections to be in line. The fitting is
started in the middle of the room, as far as possible, and
the Designpanels are fitted from the middle towards each
side in order for the frie zes to
be equally wide. The panels
are delivered undersized and
must be fitted with a distance
of up to 4 mm.
The perforated sections must be in line with their own line
and be perpendicular to the sections next to them.
F i t t i n g
The Designpanel is screwed onto either wood or steel at
every 200 mm along the short edges of the panel and in
section sizes of 300 x 600 mm on the rest of the panels,
see drawing 62.
E x p a n s i o n j o i n t s
Panel area more than 70 m, or in cases where one of the